{"Bundles":[{"AllowVibSigBypass":"false","AvailabilityNotes":[],"BundleXML":"bp007921.xml","Category":[{"Lang":"en","Value":"Application (Login Required) - System Management"},{"Lang":"ja","Value":"アプリケーション（ログインが必要）- システム管理"},{"Lang":"cn","Value":"Application (Login Required) - System Management"}],"Contents":[{"Name":"CP064922.zip","ProductId":"1655bc494b334729864d929c38544849","VersionId":"1491d75394fa433089f3444461292a8c"},{"Name":"CP065932.zip","ProductId":"35452d3049b54455b15816bf1978a61f","VersionId":"be0a1042d0204a86ac4cfc2eeaf6b666"},{"Name":"Seagate_Summit_SUMMITSUANG1.fwpkg","ProductId":"79949863b3a5452487d1035ae487743e","VersionId":"ea555e67d9a742e8bdd8e6455315b8b1"},{"Name":"cp063484.exe","ProductId":"1012a84c719148b1b9e7357e885d2199","VersionId":"f259b17ac8c1433c8ed88cb61826714c"},{"Name":"MicroserverGen10PlusSPS_05.01.05.005.fwpkg","ProductId":"134da74460bf4b5aa8511e630ba5a272","VersionId":"0de1897dad504a8daf6c66dce90f256b"},{"Name":"firmware-microserverv2gen10plus_me-06.00.03.700-1.1.x86_64.rpm","ProductId":"c046b36cf8a0464e9240313acab20b06","VersionId":"a4a10d05e61f48ca8ff25743406c9400"},{"Name":"firmware-smartarray-f7c07bdbbd-7.43-3.1.x86_64.rpm","ProductId":"02754226ca24415fbdc877dfe47af242","VersionId":"0d9dbdc9e6fe4882bcfc994a76dade58"},{"Name":"cp067177.exe","ProductId":"321dd379dd1a436ab919b4529b332ece","VersionId":"45abad3f870b4e8697b8c10cf578084c"},{"Name":"cp065377.exe","ProductId":"5413adceb7d241de900274e399d9c777","VersionId":"1092a48b7d4c48f1a608a0a2375d685e"},{"Name":"firmware-microservergen10plussps-05.01.05.005-1.1.x86_64.rpm","ProductId":"667c48761fdd439199126de11a3666a8","VersionId":"3a9ff46bfaac4f248e4cd838bb23ca2b"},{"Name":"cp065018.exe","ProductId":"83ce77cbc6db45d29c95de38716f222e","VersionId":"0c2f0cf952984c77905fe68e1e83839d"},{"Name":"firmware-system-a46-3.72_2025_05_16-1.1.x86_64.rpm","ProductId":"871bd1fc79994166a0695e4fb3b5fd65","VersionId":"ec1ac8b803c84c7b8ac5b0b690b20f4a"},{"Name":"cp066446.exe","ProductId":"e6bb5c297d78402ab079f188773b5efc","VersionId":"5a5fa0a6e8b941bea246719f09e713b4"},{"Name":"firmware-hdd-adb3ab8147-HPD8-7.1.x86_64.rpm","ProductId":"6559625804344daab70667e2f1b0b044","VersionId":"d53d764b08924595ad3cf172b8dc9bee"},{"Name":"firmware-nic-intel-1.33.1-1.1.x86_64.rpm","ProductId":"d8c86b5c3ce7444dbebf7bd215bf1a32","VersionId":"fa1eb759b39e4649b2cc5e07e16163f7"},{"Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1.x86_64.rpm","ProductId":"f148b53c7b96447699a0d01706827644","VersionId":"a1b475e80749476d9a5096114dc25e70"},{"Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-1.rhel9u5.x86_64.rpm","ProductId":"9d355b002f0f45528687c05a8ded7241","VersionId":"e55e1a44fa88467cb5b8f94eaf46d614"},{"Name":"WDC_ParisD_WparisdASFD1.fwpkg","ProductId":"29b23e8f7b0d4dbf97ddc41ea0425103","VersionId":"12e10145ad2c40a5aeb104112fcffe11"},{"Name":"Samsung_PM165X_GPM1655SAMD3.fwpkg","ProductId":"39cff1d9c55641a8a5495e9c755fc456","VersionId":"6285d7963642460bad6ca9d9e6df55ca"},{"Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","ProductId":"acccc3a79b934a56bc23c6e1a1b8169b","VersionId":"9f078413ab6e4fb6aeab7cecca2f01a6"},{"Name":"cp065043.exe","ProductId":"5ac3ee90b2184fa9828f960cd9d17840","VersionId":"14aa588a040e4d64be87d0f217907679"},{"Name":"cp065014.exe","ProductId":"4ec88340a2ce4a0da239c4051a775bd6","VersionId":"5196b480169542dcaa0fd7b08d44cd20"},{"Name":"CP066006.zip","ProductId":"fbe68804b30c4fe28e13ea472cae5392","VersionId":"cfe31a29a2d64b97b00b6f7494c8b89a"},{"Name":"A41_3.50_03_21_2025.fwpkg","ProductId":"14652a1a392747089da4a4254064ac9d","VersionId":"b36af805c7bd449c8aa7e3d1b2bd0c24"},{"Name":"cp065134.exe","ProductId":"00184010ed0a41829836f7c60269273f","VersionId":"4b48446eae8448e1b570f15be03052a8"},{"Name":"26_44_1036-MCX631102AS-ADA_Ax.pldm.fwpkg","ProductId":"b50552ebf09d445294b0b81e162643cf","VersionId":"9c75e4e9d96a4d258bf94d565b7624fb"},{"Name":"firmware-hdd-d4be2aecbb-HPD4-2.1.x86_64.rpm","ProductId":"b9b10cbec6a7489cae77c802c13728a1","VersionId":"df7bec0e2c644e30b5af706686855f56"},{"Name":"firmware-system-u64-2.40_2025_05_16-1.1.x86_64.rpm","ProductId":"716670787e144aa5b4cf080bc78d2ef7","VersionId":"236f85cbec8347b4a45c45f8a2751c16"},{"Name":"cp063479.exe","ProductId":"b929c06b33df46a182acd3e907e0dc53","VersionId":"b8feb6cede2241f6b7c3bcc056b3fbb0"},{"Name":"bcm233.1.135.7.pup.fwpkg","ProductId":"5fcadb289d2a4581aa347222e1e2d7d1","VersionId":"2f1e35091c7f48c4bff95995f6bf2392"},{"Name":"cp065094.exe","ProductId":"230d4b31fe374aebb4d538e99b933aee","VersionId":"b2198a0a7ca14455989f643803f56333"},{"Name":"cp065075.exe","ProductId":"b4de54a776434c1baf230d968d3bb23f","VersionId":"6287ed561ad74872a6bcc9f33fb128cd"},{"Name":"cp066626.zip","ProductId":"270849c2dba647ceb1f5f641d466f681","VersionId":"e0ba16e260754ac28326d491aa4b619b"},{"Name":"CP064261.zip","ProductId":"f68792033b364ab4b274dc849cf93dea","VersionId":"d03f21f7e00b40b4996d662ba82ab674"},{"Name":"cp064821.zip","ProductId":"6b0653271f3e4e3a8e730542d61ffed8","VersionId":"5b66cc941ba046d581762e8068dea3e4"},{"Name":"firmware-hdd-5dcf26fa42-HPD3-4.1.x86_64.rpm","ProductId":"896ea0712e9c4853949ccb47860e6c63","VersionId":"33f2ed7dbb3848eeb9b4d5197c3a92a2"},{"Name":"cp062267.exe","ProductId":"d6464fc039cd4a77b22febd8762dca03","VersionId":"3d164c91b5b244768a9f00ad9713375e"},{"Name":"firmware-hdd-951aefd63e-MPK7825Q-5.1.x86_64.rpm","ProductId":"7af1785af4fd43e38986cbbadda39482","VersionId":"dee9d1e3ef444e36bfc435ccabecc929"},{"Name":"kmod-qlgc-fastlinq-8.74.6.0-1.rhel9u4.x86_64.rpm","ProductId":"1aa231a863f54088aaed47c33f55bded","VersionId":"0c4e6448b66841b796bbcf31aac56945"},{"Name":"kmod-qlgc-fastlinq-8.74.6.0-5.rhel9u5.x86_64.rpm","ProductId":"1aa231a863f54088aaed47c33f55bded","VersionId":"0c4e6448b66841b796bbcf31aac56945"},{"Name":"CP066004.zip","ProductId":"6f1e3dc0362445eba42c38fd34e5d638","VersionId":"f38300f9f29d40558648ce3d9c0e2ab3"},{"Name":"kmod-elx-lpfc-14.4.473.24-1.rhel10u0.x86_64.rpm","ProductId":"74b3fe77108f45dc915915f121f04357","VersionId":"87543008a4804bdfb1f7186879a9d47c"},{"Name":"CP063477.zip","ProductId":"aedcdb1596004cf4a73ef573a3625e08","VersionId":"784bd405fd74436a833b22827ab2b7fb"},{"Name":"cp066627.exe","ProductId":"b8bfd68496a643cdaece510776fb4ad2","VersionId":"768309fda01049dbb2abd796a34a80bc"},{"Name":"cp065386.zip","ProductId":"14db461db87a4c46b9be1a6560ae1f85","VersionId":"02dcbb71ad884820b33ca4ab7e8f6522"},{"Name":"cp064795.exe","ProductId":"840d26617d5744de973393a116bf720d","VersionId":"52b860adb81246158abb9ecde83b2875"},{"Name":"A48_3.72_05_16_2025.fwpkg","ProductId":"c91a34b258694c1696514c7b51041b33","VersionId":"a2933b8eee09410db17f38e2a5464268"},{"Name":"cp065111.exe","ProductId":"130da7feaa1d444b8b70a759892883b1","VersionId":"fe3757c9f2ac476f854173dc90d7354d"},{"Name":"cp065281.exe","ProductId":"283d84a861d348648dca86da7b4218bd","VersionId":"714a3d8508994dbfa8ad3b7ccab48a4d"},{"Name":"firmware-hdd-41cdb1c9da-HPG3-4.1.x86_64.rpm","ProductId":"fc2945bc3e5744fea9d120a012546560","VersionId":"1af648eb5fe8455fb56362345ec01922"},{"Name":"firmware-hdd-24fe569b72-HPD5-8.1.x86_64.rpm","ProductId":"779f4f17fec64b6b9acf9ede668fc68a","VersionId":"1c3e90b4416b41469a31281a6de77def"},{"Name":"CP066003.zip","ProductId":"ec5fd859b967489ab6f67ad677712984","VersionId":"f33261fbafa04ae9884d1df548b7524d"},{"Name":"firmware-hdd-bdfb8e99d9-HPD8-5.1.x86_64.rpm","ProductId":"73ec3bde4c824e4abd7a12e09eb4bcb4","VersionId":"6cc11960dd3d4f65923b64b2b8c41449"},{"Name":"firmware-hdd-b1c9eaf74c-HPDA-6.1.x86_64.rpm","ProductId":"9955e8989d3a49ccb377a1c01a7b8a6c","VersionId":"54a60164ec114fcab8cf2a1356a8547f"},{"Name":"firmware-hdd-035a863453-HPK5-10.1.x86_64.rpm","ProductId":"fdd1b58860474c42b7f3b1b7524af387","VersionId":"908ab9fdc0bb45d3976c6be0b77505af"},{"Name":"firmware-hdd-c7df7ceedb-HPD8-6.1.x86_64.rpm","ProductId":"e3abad55c63d42f3bfc00d8212a8e9d4","VersionId":"4548f3f1bc454264b79206bc57b9ad90"},{"Name":"cp060559.exe","ProductId":"95e1a7b8a2664cd8b8d67128eff9bb87","VersionId":"a6b8df86acec417b902821bab4453fec"},{"Name":"cp064335.exe","ProductId":"1e10e20d274448bb9d2d1625880b482d","VersionId":"7c389a5d51614522ab0addc3b614ba45"},{"Name":"cp066844.exe","ProductId":"1bc921f76f2d48759522424a4aff4914","VersionId":"4efc8cfd981840519a9b624fb2669c90"},{"Name":"cp065357.exe","ProductId":"87793aff72a54849a327ce026784372d","VersionId":"6a450f31c1334bba95d149e834716540"},{"Name":"cp065080.exe","ProductId":"8e4da865e5b44ea38e4b650ce9a93715","VersionId":"6a72e30d8bff4e86ad74c09d80c29f62"},{"Name":"firmware-d3000-5.04-14.1.x86_64.rpm","ProductId":"d6810024a18142b0a4b8ec4db68a4e55","VersionId":"4558c10b3a5847748362b2692a0761dc"},{"Name":"firmware-hdd-abd133f0de-HPG1-5.1.x86_64.rpm","ProductId":"33179a0f0a644a26bd07818fb3f2db4e","VersionId":"8d014470a00646798e7ef5816fbbb79d"},{"Name":"CP065992.zip","ProductId":"a2bc84f793fd4972b6196baf3df85eb6","VersionId":"5268232d10d445a596b065d77b66da67"},{"Name":"firmware-hdd-8e1e8083c5-HPG3-5.1.x86_64.rpm","ProductId":"24bbe0adc4dc4c7385b6f5ad6aecf867","VersionId":"ce8115f8811442d4a6f1cdb1889d6806"},{"Name":"cp063854.exe","ProductId":"C9113","VersionId":"dfda885bb8ad4f4787ee362930d77b06"},{"Name":"cp064708.exe","ProductId":"88920b6128524213bc79e665d9b3a53b","VersionId":"f3e27b40cbd44b219097b667169a699f"},{"Name":"Samsung_PM9A3_PM9A3U3HPK4.fwpkg","ProductId":"ff59337dd3ff4f44928eba3219e493a5","VersionId":"360da88ee2a44682bb76e21ea11b52c4"},{"Name":"firmware-hdd-7a1edae8e7-HPG1-7.1.x86_64.rpm","ProductId":"41c374eaf1f14df3b6eb451ccf1a1aaf","VersionId":"a884945cece648b9b982930d7d333344"},{"Name":"cp064862.exe","ProductId":"cb3ccbb54e5e4346a7916c413650fffc","VersionId":"bdae23eafeec40f9bfd04179e6c4d4ba"},{"Name":"CP066778.zip","ProductId":"605b084308a74c74a0091e855e41c6f1","VersionId":"c27e7b6a7ce048418c000ae5896267d9"},{"Name":"cp065028.exe","ProductId":"7e6f42aebfdb4390968da43b36518880","VersionId":"edf000709f074a1fbe494396102a5993"},{"Name":"firmware-system-a41-3.50_2025_03_21-1.1.x86_64.rpm","ProductId":"d152e4f9638d4a6a962a3424ad625ef5","VersionId":"b0493928a85b48aba125332060683d8b"},{"Name":"qlgc-qla2xxx-kmp-default-10.02.14.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"eb66fafd28ff4c39a42b91395104bd05","VersionId":"80e5ba3fa3874c0ebbc4c25180551fbd"},{"Name":"cp062113.zip","ProductId":"564f69c570d840a495455ed14f4ea38f","VersionId":"2be6fee6bf3d4f7d99b86151f18b3b5f"},{"Name":"cp067161.exe","ProductId":"a6fc6d419cd14563aeefb1d3f50c589e","VersionId":"a1427232ff1d4c0ba936b0aec7c2e924"},{"Name":"firmware-hdd-10385ef3e6-HPD2-14.1.x86_64.rpm","ProductId":"1d54c8dcf99741aabe78b8a4e54d84f8","VersionId":"9d08a0ade192465ca089f5f2bbc4d87c"},{"Name":"CP065931.zip","ProductId":"cd1eb2802ed24b6aa04d98effb166b0e","VersionId":"69fa4a593266475d820dd2aa8799727f"},{"Name":"cp066625.zip","ProductId":"a07f8ac11b4a440d99aa61ea5fb0b63f","VersionId":"bf90c15126a5436c885e1096952f2557"},{"Name":"U31_3.50_04_17_2025.fwpkg","ProductId":"4de9a363a422456faca983d193ca352a","VersionId":"aca561b575c64b9ebd864d508122c62a"},{"Name":"CP065934.zip","ProductId":"cfe4c5a213fb4be397a8b588efd29cc1","VersionId":"8ac58cbcb5c54055b4aeda91c2755e86"},{"Name":"cp062258.exe","ProductId":"e485f42530b84989a3373bff82088143","VersionId":"b9cc1c533a1a4a64afbf1649fefcd8dc"},{"Name":"CP065953.zip","ProductId":"c101b138be5d4ee79271a6725d6813d4","VersionId":"839fbb262e4b4880914a769c2c486850"},{"Name":"firmware-system-u44-3.60_2025_05_16-1.1.x86_64.rpm","ProductId":"824707fd6d4844feaef370452b0a3a3e","VersionId":"d7c272a7ecd44c2c8a207d1e6c7aaad9"},{"Name":"28_45_1200-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","ProductId":"6aac2d7fdad54ca7910ee0bb1e81d6f3","VersionId":"cd1831139a214326bb39c8b766008701"},{"Name":"A40_3.50_03_21_2025.fwpkg","ProductId":"6f77f9ef4381482fb9f00a79ce325ab3","VersionId":"abc4f0a644ef4d80b19b48c06d657bc1"},{"Name":"22_44_1036-MCX623106AS-CDA_Ax.pldm.fwpkg","ProductId":"23c569ea92fb47f091a7a0c891acff72","VersionId":"7f83057f63894465b43afc28bd847389"},{"Name":"cp065088.exe","ProductId":"6b2dbf58581246349103e902007d06c0","VersionId":"eb721bc9a6e6423e8e9b0917a2d244ec"},{"Name":"HPE_MR216i-a_Gen10P_52.32.3-6118_A.fwpkg","ProductId":"2b01702f6be343c09f8208f8aab17afb","VersionId":"cd3679816f4245f5b73d4f4f5600d71d"},{"Name":"CP066009.zip","ProductId":"b1381f6ec67b40269898593ac27aca95","VersionId":"671351a63ae9400183e592bce3be61ad"},{"Name":"cp066297.exe","ProductId":"ff242e39c275472185612592300114ce","VersionId":"2e40be73ca9441de949652bc7f259323"},{"Name":"U64_2.40_05_16_2025.fwpkg","ProductId":"4502e15e8e6c48d58b299fb45b3d1658","VersionId":"3298a6cb93f34849b91732757aaa5e47"},{"Name":"cp061669.exe","ProductId":"5e67b3914b754070a44558f816a7dbab","VersionId":"00cd9a0dfbc1457ea8fa7652f2810d78"},{"Name":"cp066258.exe","ProductId":"ccde97956825448f97ee8427bc2eccdb","VersionId":"fa20d89096b14cd19137e51a191c98dc"},{"Name":"Kioxia_CD8_KACD8ALSHPK2.fwpkg","ProductId":"3e44af8bcf3140b3bef280f7e913e5b4","VersionId":"38bbc6322f054a4b9d684698cc19c086"},{"Name":"CP065997.zip","ProductId":"e6ce1a91bd5b4f829c98f53210189206","VersionId":"a7b6d297e2744431a5a1d38a6c7ad857"},{"Name":"cp066718.exe","ProductId":"01e0939311154208bbd5b8d9e5157a9c","VersionId":"72fa0e1d12dc41df90daddb7c56d33a7"},{"Name":"cp065291.exe","ProductId":"1188e33080924486b998a030d43acf6f","VersionId":"41d34f66fae5472b9825cdeb5e4539fd"},{"Name":"Kioxia_CM7_KACM7ALSHPK3.fwpkg","ProductId":"509f54411aaa488d8ade3254836debf4","VersionId":"3057a02626624a6b8dc331ea2b6655a8"},{"Name":"cp065027.exe","ProductId":"0a96bc740aee4364b774edfa452ca9a4","VersionId":"ef72f30306c0422d8d29b83faf9f4af6"},{"Name":"26_44_1036-MCX631432AS-ADA_Ax.pldm.fwpkg","ProductId":"27053985f2354572a6633cc6a63bb7ef","VersionId":"1c5dae6a3f044f1abd61c73dbd869087"},{"Name":"firmware-hdd-ec908c3650-HPG9-6.1.x86_64.rpm","ProductId":"38437d438933420e8063d6e963ffd91f","VersionId":"6ef23300d2f94eb5963698088cae87a4"},{"Name":"IEGen10Plus_1.0.0.22.fwpkg","ProductId":"4c108242693848129dadc44c03c82865","VersionId":"5ba2fe62306d406aae00e2995213020e"},{"Name":"firmware-hdd-4ba9615f90-HPD9-3.1.x86_64.rpm","ProductId":"d2753039facd45788d8eb7892e214eed","VersionId":"74601a1ea2da4cf7b34522876cd96046"},{"Name":"CP065964.zip","ProductId":"a88170da558d4ca79c0a5aa7982152c5","VersionId":"ea988c1bdb0e488ea2464583c089174e"},{"Name":"cp066448.exe","ProductId":"6d1e58e8f89340958bf7818046e9b7c7","VersionId":"7f183d5e3e9b4b91b5341e107b63956c"},{"Name":"cp065045.exe","ProductId":"17b00802f88a41f591cee6102caaf9d2","VersionId":"27d5e68a43874e2bae8e23cde47408a9"},{"Name":"CP065936.zip","ProductId":"6973afa059034a93b5842e17d11d1b46","VersionId":"fede14675b304e50949cd7916c7f0ba3"},{"Name":"IEGen10_0.2.3.0.fwpkg","ProductId":"91adee7c0766499184ce8d25a925669e","VersionId":"40c0e7a8438342b484e5d401d21392eb"},{"Name":"U45_3.50_04_17_2025.fwpkg","ProductId":"4bdcb7d3fc5c4d14af793003b89e365b","VersionId":"9c66fef2a5e24444810eda416e975afe"},{"Name":"cp067175.exe","ProductId":"f22e031456d1410688940c3efe38cf1d","VersionId":"ba9108add0d643d88bd951b946d3ed53"},{"Name":"cp065605.exe","ProductId":"8bd617958fd64494b0066602dc57ff65","VersionId":"e22c339103ae403aa80a57006327e9a3"},{"Name":"16_35_4030-MCX512F-ACH_Ax_Bx.pldm.fwpkg","ProductId":"0a8a267d13ac4d5588a19d1f0bcc2f5d","VersionId":"42c6e06f00424a398bd9a095db068d19"},{"Name":"cp066808.exe","ProductId":"36877a0ed97d40a29cfe6cb469a6e72f","VersionId":"22ee112e0b4d453ea9aa6e0e39cc022c"},{"Name":"amsd-4.2.0-2061.10.sles15.x86_64.rpm","ProductId":"cd4b5a9c9ed9405abbc5be7a9f037870","VersionId":"dbecb0f8fd1e4cee981fe7110f77fcb2"},{"Name":"kmod-hp-igb-5.18.7-1.rhel9u4.x86_64.rpm","ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","VersionId":"7d17f7591d05448c9862cdd80d224da9"},{"Name":"kmod-hp-igb-5.18.7-1.rhel9u5.x86_64.rpm","ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","VersionId":"7d17f7591d05448c9862cdd80d224da9"},{"Name":"firmware-hdd-92d876cfea-4ICRHPK3-14.1.x86_64.rpm","ProductId":"8adb99f8960b4849ba6664217211b8d2","VersionId":"e1e201bcb935409388c5a8bdcdd831c1"},{"Name":"U60_2.40_05_16_2025.fwpkg","ProductId":"31e3c0de86a045739aadd70ea35e114f","VersionId":"77ad76a0a5624d6083c3d808089ac344"},{"Name":"firmware-hdd-befd42bd64-HPG3-5.1.x86_64.rpm","ProductId":"8f93dddcb15744aab6bb426d5e84dee8","VersionId":"622cac7b41c94bcf806e30dfba395f5c"},{"Name":"firmware-hdd-faf39e0ff7-HPD9-9.1.x86_64.rpm","ProductId":"fcf6b49416e1460393e2103c04483878","VersionId":"26904f3e7b6f43158d547a46e629ac5b"},{"Name":"20_43_2566-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","ProductId":"cca7377cd12644cab41f5bd7e94cc2bd","VersionId":"e1ef68263f2345449fb9be393d817587"},{"Name":"cp065032.exe","ProductId":"b24f5415c77d43548ef3f4466312e507","VersionId":"30d8634119a042d5a3ce6f61217d78e4"},{"Name":"firmware-hdd-18e328f036-HPG8-5.1.x86_64.rpm","ProductId":"862d36dd920c478ca6dcfdb5f392893a","VersionId":"0d25c3febd0a4e3993627b8686d1f967"},{"Name":"cp066049.zip","ProductId":"ae807ea8d44943a3b60bbbbd54cd062d","VersionId":"211921c70c1543d6babbf9cbd87892c3"},{"Name":"cp062273.exe","ProductId":"81500ed23ae94776ba24fd962d1f8bd1","VersionId":"b85d3135475a417b921ccef7a253225f"},{"Name":"cp061746.exe","ProductId":"7a409aa1e5444a57b8b10f884c98ae5f","VersionId":"61ea1d640329469cbfd27fd265d2dca4"},{"Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","ProductId":"b902adf94cea4a0abb9a86aae94c9318","VersionId":"b3ac2dd86a7d4e9aa3340410288c5fcb"},{"Name":"firmware-system-a40-3.50_2025_03_21-1.1.x86_64.rpm","ProductId":"d313ecbde1f54151bf42ad357e6b94ad","VersionId":"e4c748ed27834a0d8a9deb80a73921f3"},{"Name":"Kioxia_PM7_KAPM7ALSHPD3.fwpkg","ProductId":"d5dd0878f5bc46a1b2bda19d450bbffe","VersionId":"fadd667fd8d54d92a41dc3cdbe15df89"},{"Name":"cp065595.exe","ProductId":"ffc5db5b28504df99cd08b4bf08ccc7d","VersionId":"3af3ff7548aa4d79aa67bb0e0fa7daaa"},{"Name":"cp067151.exe","ProductId":"d00882018d64492aa4a5bc81f394c4dc","VersionId":"5a440780f30643cdb209cecba7cda643"},{"Name":"cp061743.exe","ProductId":"ab1694a2c3b34d68b6e9d41c15960bf5","VersionId":"accc2576452743ab8b8c3bd27b53b7b4"},{"Name":"cp065602.exe","ProductId":"fb9faa50a5034cfe8c3861f763b25770","VersionId":"f2e37074fdfa4ce991c844227f0f4eae"},{"Name":"cp066834.exe","ProductId":"c94eb717d55e4213952a8c5723962404","VersionId":"65a0ebbebcff40cbb4c1a5be9c4ace7c"},{"Name":"cp065034.exe","ProductId":"e94dfd89626f4fc992d59a1c00e08f54","VersionId":"17a9fe4ec86a42e0a69fddf1bc1783a3"},{"Name":"cp064886.zip","ProductId":"ce9f91a90e53444d84d0e7a4367d6fd4","VersionId":"267c88992ae24d528bc292e1a24614c3"},{"Name":"firmware-hdd-ca21e169e2-HPG1-13.1.x86_64.rpm","ProductId":"02a1f5d0f0e244c0b4c2ace636d0f60b","VersionId":"b23e0a903bf244f1a64152ac37ba8eb9"},{"Name":"cp062289.exe","ProductId":"f74d68169f04405fb74a2820e48df6f5","VersionId":"929e3933ac1c4923801a2e624c30c5ab"},{"Name":"firmware-hdd-c993b31232-HPG6-6.1.x86_64.rpm","ProductId":"87b9a1c22150406cbf61d6b300753282","VersionId":"71b30ddb8a744382b3412132d4df4518"},{"Name":"cp065026.exe","ProductId":"d09d3bc174174ab69b229c1370a5ce48","VersionId":"bc236833822b4c6ba01e8efacf99b583"},{"Name":"cp065090.exe","ProductId":"4fd1e8e4a27347cd8d83d1e63d9eb38e","VersionId":"c1f741e6a2dc474395fc0f73b2d0d8e5"},{"Name":"cp067424.zip","ProductId":"d473378e1f2847f48383c6be4c105511","VersionId":"3b6b193512cf468dbcb000e245ef0940"},{"Name":"firmware-hdd-e4f147cdd2-HPG4-5.1.x86_64.rpm","ProductId":"d780ef43938c40d3a6628583fe2200f7","VersionId":"310a7ad382c14ff1a10b35fec7f90267"},{"Name":"cp064802.exe","ProductId":"d026cab87ecf46f4a70676c4643d63f0","VersionId":"e3c99f383993414c861d07819e41a904"},{"Name":"U48_3.60_05_16_2025.fwpkg","ProductId":"b8b6b31789ce4119a48876ba4b89c81f","VersionId":"9b0521eb852f45d4b097828e97857ae3"},{"Name":"cp065052.exe","ProductId":"dab6093d4d7545e892501476a1f6d448","VersionId":"b172fd70d0564d65af3fe4502861fe67"},{"Name":"firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1.x86_64.rpm","ProductId":"da6c398c130f48f9a5a32bd3c9213a90","VersionId":"37565247caeb422ab6cd3d6026a49663"},{"Name":"bnxt_en-kmp-default-1.10.3_k5.14.21_150500.53-233.0.152.2.sles15sp5.x86_64.rpm","ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","VersionId":"3f12803836424e7e9e65fa5698f6421b"},{"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-233.0.152.2.sles15sp6.x86_64.rpm","ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","VersionId":"3f12803836424e7e9e65fa5698f6421b"},{"Name":"DL20ML30Gen10SPS_05.01.05.005.fwpkg","ProductId":"aacf76bfa7674de086e8a84063eadb98","VersionId":"c67032ddacfb4f86a77f18f8bd3756cf"},{"Name":"cp065150.exe","ProductId":"b57ffa2f7fe942a89e589fe3043c5ffa","VersionId":"641cc0733124443380110ad92ce3802a"},{"Name":"firmware-fc-emulex-2025.03.01-2.1.x86_64.rpm","ProductId":"ccd2fccdbff94b0ab75d085d46522784","VersionId":"a3e31e1494d746f1b386261abca7444b"},{"Name":"cp065020.exe","ProductId":"d1880357890d41959529b109e2a869e4","VersionId":"783bec52c5a04b30b9cf367984f6aeab"},{"Name":"ssaducli-6.45-8.0.x86_64.rpm","ProductId":"7a0e2103ab3d449ea173c873ce94c871","VersionId":"eaf46305a0f0411ca0438bd239ff502c"},{"Name":"cp062900.exe","ProductId":"5ace706167bb418f8ac30077c43e3171","VersionId":"a107a6172775450aada829c057565d4e"},{"Name":"firmware-hdd-9ad359dac1-HPDB-4.1.x86_64.rpm","ProductId":"c47b4b11bb744418a62b9ae668fd0ea6","VersionId":"c076e824f52e44158dfd6bdf8dcb2911"},{"Name":"firmware-hdd-ef93133161-HPD4-3.1.x86_64.rpm","ProductId":"07a5f3ddb9bd4168818fb38406e49473","VersionId":"eb5d85635815487389c7cbf3556450fc"},{"Name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","ProductId":"8be880867f274999951d42eb0e3b0aa8","VersionId":"c5ec7a8df92342eb922c1ef6133c4f2b"},{"Name":"CP064970.zip","ProductId":"2b1131d5128b46ff8528f19d5b030560","VersionId":"f91adc82d1fb4651be71571419b2d861"},{"Name":"CP063122.zip","ProductId":"7ead0459ae26493fa240dac6ad17d606","VersionId":"2be34b80f8064dcfb76b59eb46f0311b"},{"Name":"firmware-hdd-e320db791d-MPK78H5Q-5.1.x86_64.rpm","ProductId":"5b139cd72d0b4c89818f276c3a1dce8c","VersionId":"c6fba112306145eb968f45929aec2ab9"},{"Name":"cp066423.exe","ProductId":"bce1dc60182942cc938b19de857de7fd","VersionId":"6fc4bd1f0b50483eaf9a14b955730fd4"},{"Name":"HPE_MR416i-a_Gen10P_52.32.3-6118_A.fwpkg","ProductId":"c9a4232d8cb349049f544bcc6d02e97f","VersionId":"757ded2e2d3b468a8d987bd4f3ede897"},{"Name":"CP064920.zip","ProductId":"aa3d4b3746e2485289f458134b1187cd","VersionId":"114f2e8b6d9e4deea39e74ff427c00e2"},{"Name":"cp066440.exe","ProductId":"f8437d6127664644832d2cd688d58903","VersionId":"461d8ca301d04ea8894607bd81ab3c74"},{"Name":"cp065031.exe","ProductId":"3b6a8a58b8154bb1b3a7b5b4416448b8","VersionId":"10b97c7bf5a34a379206aabbc4ecd9d4"},{"Name":"firmware-iegen10-0.2.3.0-7.1.x86_64.rpm","ProductId":"05f0508175404d989c50e4f9a4e09a23","VersionId":"4cdbdc30522a43f29cce39e54de01af8"},{"Name":"16_35_4030-MCX562A-ACA_Ax_Bx.pldm.fwpkg","ProductId":"a6a815c1e19641d7b77e2e862e63ca3a","VersionId":"99251f5455fc47e08673e58bb29ea710"},{"Name":"CP066013.zip","ProductId":"1cadb74f384743de9dfa8d9d6bc9f7b5","VersionId":"4d7a555d818942488b362fa21fb30dcf"},{"Name":"cp065064.exe","ProductId":"05aa24e5db0c41fc91f79deb60685a31","VersionId":"6045b6b150344af29ac9c978e3235400"},{"Name":"Seagate_Summit_SUMMITSUSSD1.fwpkg","ProductId":"ae57ff279aab4e628b9d7923b0985d81","VersionId":"0102a46c531c47fabb25126f64d65f3b"},{"Name":"CP065993.zip","ProductId":"97b8f64d84c04c1a9c4048cae29b4037","VersionId":"2c7206dd3d23401086d8b25ae4891eaa"},{"Name":"CP066012.zip","ProductId":"8e3928e62813480eab785be8f1d93fd8","VersionId":"f7dcdb37be9743b1b240ff29655c8201"},{"Name":"cp066650.exe","ProductId":"8ae644bee0c14cc0b7aad5521f061ad1","VersionId":"b2a8f95ae4144eb3a87ab38ecf2bb22d"},{"Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","ProductId":"a77901ff235c43f18df58616eefb654e","VersionId":"e2fbadb5ead3419e9adfd4a63f824341"},{"Name":"cp065061.exe","ProductId":"8ebc8805a4344ec4a24a5c7109c6e07f","VersionId":"ce5e8120b98f46689afdf5157ada423c"},{"Name":"CP065996.zip","ProductId":"5829ee37bc994558baa6a98dd52b6154","VersionId":"025ff32032524897b703ad63972d6a09"},{"Name":"Samsung_PM165X_GPM1653SAMD3.fwpkg","ProductId":"9adece559a5e4fcf8de67cd47aa7d7c7","VersionId":"d03b979005d741c397e716fd188f48dd"},{"Name":"cp064345.zip","ProductId":"1b2f6dbb532f4c6ca53c07209cbe6b16","VersionId":"efd45025f131446c8a82a2b5fbf98968"},{"Name":"CP066007.zip","ProductId":"df6ba3c2e569412ab3999b9575ddb1d8","VersionId":"b900be4b099045c3a7fa9b0424ade33a"},{"Name":"cp066952.exe","ProductId":"7eb6e3adc2094748b6a18ae2e5daf1e0","VersionId":"1d3865cb5ec6429dab8f1264deb31ed0"},{"Name":"firmware-hdd-a05f29cef3-HPDD-3.1.x86_64.rpm","ProductId":"365d207e25654d61b3829f731965d204","VersionId":"900220780b604d868392d1ac449defec"},{"Name":"cp064930.exe","ProductId":"e951bbca527f4f9f8a089c23c99574fe","VersionId":"cd02663ccc924a72a399b86dad8b8d94"},{"Name":"HPE_E810_2CQDA2_O_SEC_4p71_PLDMoMCTP_80020037.fwpkg","ProductId":"58e30c6460374d34ab64c2a8547dafe2","VersionId":"8c1c80938d4045c08dce59f0193203cb"},{"Name":"cp065022.exe","ProductId":"ae6b2b73e1ee45bc9e25c451f9dd6d2f","VersionId":"0491985370564855a46c53fc71569de0"},{"Name":"U61_2.40_05_16_2025.fwpkg","ProductId":"a96fcafbb6d4411b8c5383684726a0e9","VersionId":"c39f2bff73b642e2b52bd6ced12061f2"},{"Name":"cp066840.exe","ProductId":"bf6c1988a6474823969dd84808070288","VersionId":"f3512aa578b34f299641d796d51b7362"},{"Name":"firmware-hdd-ae6b41e855-HPD8-7.1.x86_64.rpm","ProductId":"f66d2f40fe3b49a2ae22ce155e429f5c","VersionId":"2c253ad9c23c4bb1b90ac566e1061483"},{"Name":"cp067581.exe","ProductId":"c3e42591dc7346b48d6b9ae18a9810a3","VersionId":"aa52227feb564647a7928cd6a7ac6372"},{"Name":"cp060558.exe","ProductId":"e1ccea24a14a427dabc2aadd846feea9","VersionId":"1f4c9a2df6554218adf6c3f194864d69"},{"Name":"firmware-hdd-bfc4af697b-HPG6-13.1.x86_64.rpm","ProductId":"6114e7f77ac240e69cf280b518ec5e27","VersionId":"7623e8263668475faf0b510f095be71d"},{"Name":"cp060551.exe","ProductId":"45e734b674094fd09fe52836988b3440","VersionId":"20015faacfff4d009860a489fb8cfc18"},{"Name":"cp066737.zip","ProductId":"7ff6f17e72894f4e8c910355a9fb9992","VersionId":"891f2ffc824a4cc49041d895d19d7c6d"},{"Name":"CP065978.zip","ProductId":"a6c377914cad4568810f0a24fc0faa52","VersionId":"828713c2b35a4640b56377bf5971b97b"},{"Name":"cp067146.exe","ProductId":"707f07cb4d404d119f2788d168e17586","VersionId":"5ee48f0aa9284b27ab61f4f628dd67d4"},{"Name":"cp062270.exe","ProductId":"0f3487315f10473a903e3c353d754526","VersionId":"face9ded467b4920bb57a17e35fae531"},{"Name":"cp063483.exe","ProductId":"8085229a62d8443d85751340431d38d5","VersionId":"30ae2e511d3e4e14ab35fa01b5767023"},{"Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.700.fwpkg","ProductId":"189fb9052e994ac694bd5d6fb410f76a","VersionId":"504921384b134492ad7af4ad9b03abcf"},{"Name":"U32_3.50_04_17_2025.fwpkg","ProductId":"7db6f792355b49a58fc4f82d6bbbdd99","VersionId":"4d93b2498b974df0829d7f866552c246"},{"Name":"fibreutils-4.2-1_sles.x86_64.rpm","ProductId":"a32bfc6464f84b51997e9a09f493113b","VersionId":"d76ea60ae7e648c88a52e39902b4937c"},{"Name":"cp065078.exe","ProductId":"139d2679780d42b2a020c2a6176ac11b","VersionId":"4c19f0e833784a33b6cba21d152c3408"},{"Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-1.rhel9u6.x86_64.rpm","ProductId":"62fc8de385854321919207903df8d568","VersionId":"34ca4717df694227ae59cb8da7f7cd06"},{"Name":"cp065577.exe","ProductId":"10b8cebc40fb4b69b234ff81bd7e1d1f","VersionId":"f01f7319145545cb8b3a036cdcc75b16"},{"Name":"cp058499.exe","ProductId":"228e6aefb0ce46a0a7e230319e326d29","VersionId":"5b37c95077cd4ec283667430951de6c1"},{"Name":"ssacli-6.45-8.0.x86_64.rpm","ProductId":"51c52bf006bd4c60b09797563ff886bf","VersionId":"d7db6433534b4431af0282776d796e91"},{"Name":"firmware-smartarray-7b5e8400dd-1.27-5.1.x86_64.rpm","ProductId":"b94490ecb4854ca6989ed2491e061c4b","VersionId":"21ceab93a88b4ed6bedc7237f1e7b689"},{"Name":"CP065943.zip","ProductId":"001e7fbaf67f420ebcb746aae6b4aee2","VersionId":"40e0ce11db3743dc8166e4a30a532fbc"},{"Name":"firmware-system-u47-2.42_2025_06_13-1.1.x86_64.rpm","ProductId":"e9a45a84fc5a4ae9bee13ee0419530ca","VersionId":"24ac1d0af5734096a1a6c252a29b7919"},{"Name":"kmod-elx-lpfc-14.4.473.24-1.rhel9u5.x86_64.rpm","ProductId":"e760dc1509734b53830053c8a8b00097","VersionId":"073cc30642e344b08af7bce7041b3707"},{"Name":"cp064863.exe","ProductId":"4273bdba1b2e4a8c9b15a6a2a834ba78","VersionId":"9c21d4ef34874c3284e1dbd96ab732b3"},{"Name":"cp065089.exe","ProductId":"0d61334622ba44aeb0c163514d9f57b9","VersionId":"825f8f70031e41b6b87a9ca3c7e76052"},{"Name":"CP065994.zip","ProductId":"1359633a2c01457995b30369968ffed3","VersionId":"cba9f17f0d1d4a0bad974e39adc53f48"},{"Name":"firmware-hdd-e0171a2936-HPG4-4.1.x86_64.rpm","ProductId":"a905a1ce40514e0aba7f765d4f2557ae","VersionId":"29490c1919014fd5acd7110b6ce7300e"},{"Name":"firmware-hdd-8f501d6cf1-HPD3-3.1.x86_64.rpm","ProductId":"b271ca95088c47b0b57cf56bd9562a4c","VersionId":"6d2cc028a6634968b95285c47072c535"},{"Name":"mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm","ProductId":"0094fb3b638e464a8e8862430ee704a7","VersionId":"43f4fadf81fc466bbcac3412d321f4c6"},{"Name":"kmod-mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm","ProductId":"0094fb3b638e464a8e8862430ee704a7","VersionId":"43f4fadf81fc466bbcac3412d321f4c6"},{"Name":"CP065958.zip","ProductId":"d7a820130b1346d2a8d4377d479232cf","VersionId":"de5f63eab149463783b82001b23764bb"},{"Name":"cp064858.exe","ProductId":"b0d91a06dd9c4473a208b93b1c088e41","VersionId":"bd84dd8f923649f298b07b431857d1d1"},{"Name":"cp065095.exe","ProductId":"57a91e286d3e413c8468376551e64001","VersionId":"abd55f024dad4770a6b1f8ab350a2fd7"},{"Name":"cp066315.zip","ProductId":"ce8ca413963e4458ade3268c0f9831f6","VersionId":"e6307a46904e4adc8214e64498f63d2b"},{"Name":"cp065017.exe","ProductId":"074cd65cf284444dbd64a63e5f809ff6","VersionId":"2a3cb2c333614f13ab550c9532b37c85"},{"Name":"firmware-spsgen10plus-04.04.04.702-2.1.x86_64.rpm","ProductId":"78667359eec84fc9af9066672db940e0","VersionId":"bd50dc1d0a974f47843139494885fec7"},{"Name":"libbnxt_re-233.0.152.2-sles15sp6.x86_64.rpm","ProductId":"b00b4afad66b4dd386d098e91550601d","VersionId":"db0e704fada44715a9f7673595f93c13"},{"Name":"cp067580.exe","ProductId":"6d1ce52e0d6c4c48a4cc6f903852d87d","VersionId":"09dd4d40b1b64f9e98c36b86d4921159"},{"Name":"CP062902.zip","ProductId":"4f319faf890642fc80a3d8719760c121","VersionId":"8b9e6674e08f45ae9d3cbce47825d4ca"},{"Name":"cp058604.exe","ProductId":"C8510","VersionId":"97280984c2244463bd328b630122b3ca"},{"Name":"cp066717.exe","ProductId":"594618f566cc4fbca055e8866278e53d","VersionId":"72b60c0935f34af89709615a8b32cffb"},{"Name":"CP066001.zip","ProductId":"c19eee3c7a1046a4aeaff35e462fce56","VersionId":"082b90a7fe714b2dba1a8cee129c9946"},{"Name":"HPE_E810_CQDA2_4p71_PLDMoMCTP_8002003C.fwpkg","ProductId":"f3f8a4081d78499e9a2dd9c8d9fb4059","VersionId":"c548e51f97194a5cac22a4bc37aa4bcb"},{"Name":"cp065047.exe","ProductId":"96853662d13b4def814a5c153a747271","VersionId":"211977b6d5a44c7db30905f765e7d4e7"},{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.4.473.25-1.sles15sp6.x86_64.rpm","ProductId":"3a4168637f45404b864aa9e998210305","VersionId":"c9dc9c6017004bd4a0a28c5e58d4706a"},{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.4.473.25-1.sles15sp7.x86_64.rpm","ProductId":"3a4168637f45404b864aa9e998210305","VersionId":"c9dc9c6017004bd4a0a28c5e58d4706a"},{"Name":"kmod-hp-iavf-4.13.4-1.rhel9u5.x86_64.rpm","ProductId":"6d5b098230e341e9881e9381bf19ba96","VersionId":"04f238a593334138862984cf5972ae52"},{"Name":"kmod-hp-iavf-4.13.4-1.rhel9u4.x86_64.rpm","ProductId":"6d5b098230e341e9881e9381bf19ba96","VersionId":"04f238a593334138862984cf5972ae52"},{"Name":"cp065360.exe","ProductId":"e774fea9b642407a9f2687df296d352e","VersionId":"ba6070dd4fe74a3a9ce556ab65af395e"},{"Name":"hp-igb-kmp-default-6.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","VersionId":"753411979d734eb19ab05458b72b4aba"},{"Name":"hp-igb-kmp-default-6.18.7_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","VersionId":"753411979d734eb19ab05458b72b4aba"},{"Name":"firmware-hdd-1a541ed00d-GPK5-8.1.x86_64.rpm","ProductId":"e4dd84a160cc43f1b620391e92c1a737","VersionId":"e4a29c09aacf43838832ec7d2367b751"},{"Name":"cp065359.exe","ProductId":"ed78d2df04834204b8977e0aaa96c64a","VersionId":"08a951b693a542e6a6176cef7005c7f1"},{"Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","ProductId":"95cd675c9c4947eda03bc921bfff84c3","VersionId":"22b25cb7056247fca6f226ad387ab8a6"},{"Name":"firmware-system-u43-3.60_2025_05_16-1.1.x86_64.rpm","ProductId":"d3e8a053234f49d9a3735931f34c77c7","VersionId":"282e2c21ad294d829e332e8a233d2cec"},{"Name":"cp067430.exe","ProductId":"8fe22752c5324386870794853904b4ba","VersionId":"67362ac752ab407d8f4bf8809227fd55"},{"Name":"cp065065.exe","ProductId":"38d3787c49804ab1b404f61b3cd58354","VersionId":"6d790f894e5f478fa1f5f02962010122"},{"Name":"CP065949.zip","ProductId":"dc0fcbf999ba4988aa8b4eae8e8c9889","VersionId":"3b34a42dbd6f4c9aa3887be86849e669"},{"Name":"cp066439.exe","ProductId":"4ecda510f4cf4aef9ac80ad782d1c36e","VersionId":"da6c9845084147d7b1be8cb4c5082633"},{"Name":"firmware-fc-qlogic-2025.05.02-1.1.x86_64.rpm","ProductId":"bca5397d7ba147ddbb0eb4fee4d4d567","VersionId":"840d82bb470f45dcbef9c8396b8a5ccb"},{"Name":"cp065148.exe","ProductId":"e79fad26938d4b788f99ac1b9d5aa529","VersionId":"4a3ee2fcc92b4240b2b09f9b5fb44a25"},{"Name":"firmware-spsgen10-04.01.05.105-2.1.x86_64.rpm","ProductId":"84d998355c4f4bc6997437e9a6c61fba","VersionId":"d24d95b6be5b42679f82bd43de48a53b"},{"Name":"cp066777.exe","ProductId":"cdfe3840d6074900a4d11b774d3e5307","VersionId":"fab8d90d6d734949ad99dd08071b4056"},{"Name":"cp065282.exe","ProductId":"7998b80f937f47828d4693eb2d620eec","VersionId":"76eb83a73c664b0c9e93bdd8ff3b21d5"},{"Name":"cp065054.exe","ProductId":"63976963938d4f79be04f7b652abb966","VersionId":"c35a12155a584e44b0c05562951dde53"},{"Name":"firmware-hdd-aef2a690c9-HPG5-12.1.x86_64.rpm","ProductId":"29456540dcc74eaf9f223e63cf50eff7","VersionId":"6a76cd63c54044e0b983d1a765d11f88"},{"Name":"firmware-hdd-82894b9e0a-HPG1-13.1.x86_64.rpm","ProductId":"d7cf155e76584b1f8fb8e3c7c222c90d","VersionId":"7f127a30827c40f2bf459c13df58ebcb"},{"Name":"firmware-hdd-cfd7436fcc-HPD4-4.1.x86_64.rpm","ProductId":"6cc89934ad1740b582b096e05315f04a","VersionId":"c0d031c28dd24a87ac47ffc4f2879dd3"},{"Name":"CP065968.zip","ProductId":"d1014161143144dea5631e9b65f9f0d4","VersionId":"236ab9557d1a40f590bd1a3fb3c0a893"},{"Name":"firmware-system-u37-3.50_2025_04_17-1.1.x86_64.rpm","ProductId":"c02f997871554705a1c6e597965673df","VersionId":"bc124d2779ba4d83baa4b4a092bd2859"},{"Name":"cp065607.exe","ProductId":"d9b51eadf7e440fc88f26963aec59690","VersionId":"bffaa737741b41878092a3c32ffba815"},{"Name":"cp065060.exe","ProductId":"4106b2f5d7c1411c95e94d52dff63df7","VersionId":"292651a9b46e48c4ba5741942314a6b9"},{"Name":"cp065597.exe","ProductId":"56422dc0cdb64171addc0c9909a7019a","VersionId":"d5e8290846824f9db5ef0276c59eb3e9"},{"Name":"firmware-hdd-7f2a26e6d0-HPG1-13.1.x86_64.rpm","ProductId":"d33174a587ab4b3ea4d5e4e22de786d1","VersionId":"e758ba908a834c6394a32bd2a2b9fc34"},{"Name":"cp065283.exe","ProductId":"8f4fd902230c4076905c23b7ab80bfdf","VersionId":"2afdacbb67de47c5b45bc737cb9d4aae"},{"Name":"A42_3.72_05_16_2025.fwpkg","ProductId":"a745e380a94147888b60792dcbb594a8","VersionId":"2ff8dd25bd2c4e49aaaef28ceb88dcc0"},{"Name":"CP063146.zip","ProductId":"fe217a349ea5432eb992dea833e5cc7b","VersionId":"d3c13232dc0145eba7a616305103d5a9"},{"Name":"cp065030.exe","ProductId":"d05a1433339f497faa2734fb31c015eb","VersionId":"69cbde52ac6c497191b3b8ddeae80484"},{"Name":"SPSGen10Plus_04.04.04.702.fwpkg","ProductId":"6e357a862ebf4f379b5f531a7eb46680","VersionId":"21a9d63886a74bd2b8f222218e178c46"},{"Name":"CP065957.zip","ProductId":"cf7cb50c769b4b00ab89aa81d9fac797","VersionId":"8fe40c9bdbd145d3bc4d739f464f1c54"},{"Name":"cp066257.zip","ProductId":"6847395ba4ef4b018475096e40729a70","VersionId":"54ee325a61e84639be6b288cef1e89ee"},{"Name":"CP065962.zip","ProductId":"423cc31f15944616b9452d63683a53fd","VersionId":"2a3d0186209540c38458e0ca34d601e8"},{"Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp5-1.x86_64.rpm","ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","VersionId":"24b6b1f981844df785c055d4910ae5ed"},{"Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp6-1.x86_64.rpm","ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","VersionId":"24b6b1f981844df785c055d4910ae5ed"},{"Name":"28_45_1200-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","ProductId":"f56420e1793d48958fc061b802e973db","VersionId":"6c78946b9648457aa05fb443b115ce09"},{"Name":"CP065972.zip","ProductId":"66a1346762c14adc98a81649c4277c93","VersionId":"34731ffbed904cd2b0f1fce85be60590"},{"Name":"CP065961.zip","ProductId":"0e268c49682a427da167d2f123ccafaf","VersionId":"2b24794bc5944b7380c4d0cd633563bd"},{"Name":"CP065970.zip","ProductId":"c5274a8d3e3e40d790c226da85bd84aa","VersionId":"9ca3dd9ecb244e43acb9e5fe9d0ec0cb"},{"Name":"cp065038.exe","ProductId":"3c5ca1f7884d46278989b90e474b83e1","VersionId":"21953a197a564d96a90ac765cb067606"},{"Name":"cp065296.exe","ProductId":"000bfbde35e84381b78976b2c1748662","VersionId":"59e38000703848e5945b59577afa4ed6"},{"Name":"kmod-bnxt_en-1.10.3-233.0.152.2.rhel9u4.x86_64.rpm","ProductId":"c549eb5726da4e0ab54cbcdd6abecebd","VersionId":"6a072d3d9c654382b1076084b956d04a"},{"Name":"kmod-bnxt_en-1.10.3-233.0.152.2.rhel9u5.x86_64.rpm","ProductId":"c549eb5726da4e0ab54cbcdd6abecebd","VersionId":"6a072d3d9c654382b1076084b956d04a"},{"Name":"CP064939.zip","ProductId":"84e7c2b1f88e4ba3ad8fe3ec63fe5a60","VersionId":"3b1c718ef1b648f69d52e15b0a96a050"},{"Name":"cp065269.exe","ProductId":"2433baff8f4443ed8ddae6e9a115bc4d","VersionId":"76402b75677d4c258cfc388969d9a716"},{"Name":"firmware-hdd-87b796d9ae-HPD4-4.1.x86_64.rpm","ProductId":"630e644160fa42ef980745ef1697fa39","VersionId":"1ba9c1ea08be45cc8bb840bf7a2d0da9"},{"Name":"hp-ixgbe-kmp-default-5.22.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"3ab4de78da484144892d6ddcd8fd9b97","VersionId":"4becb267edcd49a3820aa03003cc811a"},{"Name":"hp-ixgbe-kmp-default-5.22.25_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"3ab4de78da484144892d6ddcd8fd9b97","VersionId":"4becb267edcd49a3820aa03003cc811a"},{"Name":"CP066430.zip","ProductId":"d65fb45f0327449eb7763d2d9cb7bf3e","VersionId":"acde336247b04c929931baaca6b17520"},{"Name":"HPE_E810_XXVDA2_SD_OCP_4p71_NCSIwPLDMoMCTP_8002003D.fwpkg","ProductId":"fbb53cf22a594dbb99b8c7f89e562124","VersionId":"a0dfe3fe6cd2438a867fcd6b1bbf7f86"},{"Name":"CP065976.zip","ProductId":"865064fe88324b7ea65c940d300f10de","VersionId":"2e40f73a1fb54c0abb55aa2da3f59574"},{"Name":"22_44_1036-MCX623105AS-VDA_Ax.pldm.fwpkg","ProductId":"f5b93810cc2347bb802707c26e414376","VersionId":"ca0efb5f527a4effad0254cffd6d944d"},{"Name":"U47_2.42_06_13_2025.fwpkg","ProductId":"a294766010e4496a9a5cf2711f22fa84","VersionId":"91ee6f429bbf4a57b913d12f6024346e"},{"Name":"cp066819.exe","ProductId":"0e95d953f6c341e2ab45544cad6adaa1","VersionId":"f5fe2372ea3b42058cb56673a96b5674"},{"Name":"HPE_UBM6_1.04_C.fwpkg","ProductId":"923bb6bba3254a6d80257c1bf056f39d","VersionId":"96ab565fa9d9472197e8151242b94100"},{"Name":"20_43_2566-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"3f4d9eceae63421389745abdf06f001a","VersionId":"18b949b5ca454f8ca429e432693e3356"},{"Name":"cp065069.exe","ProductId":"3b83490f55194800be58721a957dd6a1","VersionId":"1a83dd24e90b43148e98ce2733b64821"},{"Name":"CP066779.zip","ProductId":"75dd01ca72594b0686b5c281ad30ac2a","VersionId":"df2562496c8f4269a1d39aa8f6df8cf1"},{"Name":"HPE_MR216i-p_Gen10P_52.32.3-6118_A.fwpkg","ProductId":"87a7eb56c25b4c4c98ceb5ea24664524","VersionId":"b67872fae91a4ce59cd901fe1f0a74c8"},{"Name":"bcm233.1.135007.Optimized.pup.fwpkg","ProductId":"8d2bd99747b540d2a364efef8e58a91c","VersionId":"f9f6c8d4f7714e8e85d4276f664f48dd"},{"Name":"cp065297.exe","ProductId":"ad3fba5acbb54355b6ab78730e8d2635","VersionId":"7f76976e07a54576b8e018fa2fd129a5"},{"Name":"cp065033.exe","ProductId":"0c95f7c054f047b69fbfe7c93264a982","VersionId":"b3c2b4c403c3491c8fba712a8c254a5c"},{"Name":"cp066447.exe","ProductId":"1174220fe8354722a040071980d1eb37","VersionId":"927d2f75e08f4b78ad4231a8b92b10d8"},{"Name":"cp065358.exe","ProductId":"dac1034844fb4856950db71b5b2c959d","VersionId":"5104ee92a3724161bb39d8e94e7f7bbc"},{"Name":"cp065087.exe","ProductId":"968a9e036afd4092af43608fa1a5a87c","VersionId":"338e51f3673543e4a0e92ad7a9f40137"},{"Name":"firmware-nic-bcm-nxe-1.24.0-1.1.x86_64.rpm","ProductId":"7dbb2b9a498c4df1a461e7b3079cc8f5","VersionId":"0269876a1583462b91a9e5019d2583a8"},{"Name":"cp065355.exe","ProductId":"5f4b3c5f1985447a820cdfec1e7b0bb1","VersionId":"a4d6893352c4492680ca1df4f865180e"},{"Name":"firmware-system-u41-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"d36b5614c00b4d00b66a58209cc5bffb","VersionId":"0e2b2c3c3b83469abadd65dc7e0102bb"},{"Name":"cp065265.exe","ProductId":"be56d38accd045cca89d446f2db8440b","VersionId":"59d68ed4847143f2b56bcc8f6f1969f0"},{"Name":"cp052054.zip","ProductId":"d3fcc87b38304a8db3d98d71c7c32227","VersionId":"710b214b710b478db82f6f2cc0c9f094"},{"Name":"cp066831.exe","ProductId":"ccbfcdbdc47644e7ab18a371d4af9d7a","VersionId":"f3aea5705c5041648ac218de904b8e77"},{"Name":"kmod-ice-1.16.4-1.rhel9u4.x86_64.rpm","ProductId":"a5b53b4bfa36450dafe72d3912e27c73","VersionId":"fb00fd55e60c4887bd3a930235a5ab2f"},{"Name":"kmod-ice-1.16.4-1.rhel9u5.x86_64.rpm","ProductId":"a5b53b4bfa36450dafe72d3912e27c73","VersionId":"fb00fd55e60c4887bd3a930235a5ab2f"},{"Name":"A43_3.72_05_16_2025.fwpkg","ProductId":"bafc8d47aead420a9621e8d49861aa9b","VersionId":"467b3c64de644d70b2e88eae3f7244e6"},{"Name":"qlgc-qla2xxx-kmp-default-10.02.14.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"2ef4b1fccb0b4e4aa4c8281327ada522","VersionId":"8482fa2bf1c34b14bb1dde5a7ea729a3"},{"Name":"firmware-hdd-cf0b6cabe1-HPD4-6.1.x86_64.rpm","ProductId":"fa3afb08b69b4eb3ac32d9088c68d3a9","VersionId":"20535a82fb3540f4b28c1aadb59ee7cf"},{"Name":"tg3-kmp-default-3.139t_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","ProductId":"8e8482d9e6e6494a8e54ec40143d190a","VersionId":"b7369d1a8a734e8fb6e03985f2673c85"},{"Name":"tg3-kmp-default-3.139t_k5.14.21_150500.53-2.sles15sp5.x86_64.rpm","ProductId":"8e8482d9e6e6494a8e54ec40143d190a","VersionId":"b7369d1a8a734e8fb6e03985f2673c85"},{"Name":"20_43_2566-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"e6fc00ad6a3e4c539778e7419a9fafa6","VersionId":"7dfe5a924aae4c9f83d18e91ab938d50"},{"Name":"firmware-hdd-8a0371a425-HPDC-2.1.x86_64.rpm","ProductId":"aa62b707fef04bb99492053e558daffb","VersionId":"5f7c07702a8741cbb71faac1d8ea0595"},{"Name":"cp065077.exe","ProductId":"dd83343964ed4806840a86595ee2254d","VersionId":"9dc081801c834a77aff4e4ab311333bf"},{"Name":"cp064820.exe","ProductId":"ae86717eaef841a7919ea42f85ca3fe7","VersionId":"df05d5e27fe2442bbc0ca33e6318e933"},{"Name":"Kioxia_CM7_KACM7ALFHPK3.fwpkg","ProductId":"9f1ff08535434ba0ad3d9924079f9908","VersionId":"1e716f77e5834081b2f12ab399b85ff2"},{"Name":"ilo5_314.fwpkg","ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","VersionId":"2fc444a8965c494eaa0d5ff790004e14"},{"Name":"hp-iavf-kmp-default-4.13.4_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"5156ee2ce74d4685bd9c2931c6170220","VersionId":"b1189f681d5a42949cac7ad8da749295"},{"Name":"hp-iavf-kmp-default-4.13.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"5156ee2ce74d4685bd9c2931c6170220","VersionId":"b1189f681d5a42949cac7ad8da749295"},{"Name":"CP064176.zip","ProductId":"e1df01bf9927457096858061671e6c6b","VersionId":"3b2772bb95114a73a40b1b23736ad535"},{"Name":"CP065951.zip","ProductId":"92d52e2161c24f8f9ff633da842f814c","VersionId":"2b4c0646f81a4caaa9e5e1f7aac8a0ae"},{"Name":"CP065930.zip","ProductId":"5e76fbf672b8432aa6436d748dacb463","VersionId":"e55788193b7641ea9c26ad4ae15c77bc"},{"Name":"Micron_7500_Micron_7500_M7500ALLHPK1.fwpkg","ProductId":"90a21d24fe854b07a035a8e7bf0e3602","VersionId":"738d3ecbd42b4b8d832987815cfae4d4"},{"Name":"U50_2.42_06_13_2025.fwpkg","ProductId":"7fe88b20c8c948e29d704473f3133fee","VersionId":"95a65967f82646d782c98dd904596bbb"},{"Name":"cp065057.exe","ProductId":"54856ac460a544e2985eadac24abf907","VersionId":"a56644069bc04f4091ec00136bf08f37"},{"Name":"cp065149.exe","ProductId":"b9dda486435f4c78a30de5b1c831c135","VersionId":"da8ccf4d6e9b4059a21d60c802b20a3e"},{"Name":"CP065948.zip","ProductId":"660aa31b4e5e4c7fa47517faf21f93a1","VersionId":"f71d0aa764ae4c37b94b0a977af328e9"},{"Name":"cp065079.exe","ProductId":"260b73b77b824e60a7231a400ce24c25","VersionId":"15f5c75b81104174b2aabc9a5bfc68f5"},{"Name":"cp064340.exe","ProductId":"dcd60b858b6c4ac298dc49b61299aeb5","VersionId":"37f4e45347274f90b807bba74f66b67f"},{"Name":"firmware-hdd-8fafc9efb2-HPD8-4.1.x86_64.rpm","ProductId":"9fd1abd8973f4c09aa450e541dc4ee41","VersionId":"47b6d734ca17469da8d7f53f8ed57529"},{"Name":"CP065266.zip","ProductId":"a08198f75ae64d5f81f313aee3e10a81","VersionId":"9e01a07a1e5a426e961dc7a6cfce916a"},{"Name":"CP067552.zip","ProductId":"64511cd7ad8d42fea109336ca7a083a0","VersionId":"5397303bc0924471a4fb13298ee68845"},{"Name":"cp063922.exe","ProductId":"5e23a12643374784bca02e8442853ff7","VersionId":"03c3e74c021b40b2a14f0c5cbbbd4f1c"},{"Name":"firmware-hdd-726d5ec795-HPK3-5.1.x86_64.rpm","ProductId":"1d14b3fb06db4e8a9306176914f7f80d","VersionId":"de84cd483dce4e64ac53b30e6f3f6f77"},{"Name":"A46_3.72_05_16_2025.fwpkg","ProductId":"17ae190412f049ff80b7f941eb9e3732","VersionId":"96a88056b00f4e43bdf0c62c849c201e"},{"Name":"amsd-4.2.0-2039.8.rhel10.x86_64.rpm","ProductId":"fc90f99dec3d4432a73ac738a336cdc1","VersionId":"2a3799c1b42e45c0a52cfe294c20cbe2"},{"Name":"firmware-smartarray-f36d4ef431-0.39-7.1.x86_64.rpm","ProductId":"e528a2af212b4bb09bfd3cb54b985653","VersionId":"958d8f91bb5d41cd9d929ecdf1576fd8"},{"Name":"firmware-hdd-95af9a555e-HPG6-6.1.x86_64.rpm","ProductId":"e8a7c3696813408f916249b859b6b722","VersionId":"b945c98a835b499e8f68dafbb0b7a039"},{"Name":"U34_3.50_04_17_2025.fwpkg","ProductId":"170e9646d84b43c984c43d017aedc665","VersionId":"50dbd5a98a4e49109f996810bc3a916f"},{"Name":"cp065070.exe","ProductId":"e5d8389759aa4832a8475a2ff763f16b","VersionId":"dc8a95ccb989492b910a7a8f79e83bc3"},{"Name":"Seagate_Summit_SUMMITSUASG1.fwpkg","ProductId":"575b91de95af482eb3a08ed94402e2c3","VersionId":"675c69d416134f789231a11d446f13a9"},{"Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","ProductId":"66cb80b1d5d040ff8edbcf313b0e2f9d","VersionId":"cb947df2b7494b02a1ae11bb036e5d53"},{"Name":"CP067636.zip","ProductId":"7a882d320d3b437c96a87679f2b6ee8f","VersionId":"895b3c616f16488f9f137a19d5550aca"},{"Name":"cp054321.exe","ProductId":"8dad994cacb24e87b613f12e36f4c8c5","VersionId":"ecf8cab070b24650ba98c6d26cb25ed0"},{"Name":"cp060555.exe","ProductId":"b75caf763a204707bef1840fcde5be6a","VersionId":"7326920731fb4fbe8fc5c1297853e3f2"},{"Name":"CP065987.zip","ProductId":"cc96bd351eff4426bf37f3da741a7623","VersionId":"2e372effed5940ee9e19594f3202980c"},{"Name":"HPE_E810_CQDA2_OCP_4p71_NCSIwPLDMoMCTP_80020036.fwpkg","ProductId":"dc41774861a945f28d388059e656b2ca","VersionId":"6177a06c1b2c4c6ab5c51b78fd9f2509"},{"Name":"CP065995.zip","ProductId":"0f2b8614c6ab40aea6c15cd633ff1402","VersionId":"8fff860ffbd24a8098156de57480237f"},{"Name":"cp061745.exe","ProductId":"7a38c76de8ff4383970907d2998b1740","VersionId":"301e079f71814412bbc686a6a7b00750"},{"Name":"firmware-hdd-aaf1014ede-HPD4-4.1.x86_64.rpm","ProductId":"421cc08cc7bc4143866089180c719d3f","VersionId":"ce0c8b931dc944eba16ec625f8c05959"},{"Name":"firmware-system-u60-2.40_2025_05_16-1.1.x86_64.rpm","ProductId":"52c884546e0a44fb8cddfd654ad71e81","VersionId":"c6ae859b972e4052b9275806e29e42c2"},{"Name":"cp066449.exe","ProductId":"e33bb1d2f7324af98ab1d5f7897ec4b5","VersionId":"f9274c317c5d4c95adf53aaddcd99bb3"},{"Name":"firmware-powerpic-gen10-1.1.4-6.1.x86_64.rpm","ProductId":"d6cef3e7c9484a989ca5a04fc11b29f2","VersionId":"e17dcb3b519845f7b31f35d0fd0ee576"},{"Name":"cp064824.exe","ProductId":"6d4e51e8b4c040cc80275ae447831403","VersionId":"7fbb1bdc104742a299d7ad41138dc31a"},{"Name":"CP065971.zip","ProductId":"261c2f9a8f584fd69c7ae5c1643322e4","VersionId":"5bda8aab3a0f4794810c9b2b92732953"},{"Name":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","ProductId":"5f7dae044b3b4d97823b1cfc69305837","VersionId":"67291762a5054079aef09cf140b67273"},{"Name":"cp067694.exe","ProductId":"9a74de9c33bb4afeafe66492b230f37e","VersionId":"3f85cd35cf90442f80873947db78ad39"},{"Name":"Micron_7450_M7450ALLHPK4.fwpkg","ProductId":"f85aacf9018c4fbdadcdb2b9bbf03fed","VersionId":"b8cf44de46d94ae9b0f6781016022a00"},{"Name":"firmware-hdd-9475583fb5-HPG1-5.1.x86_64.rpm","ProductId":"cf3d0ea161014094b2ae4ebd26456a93","VersionId":"8913f08ab2ed4d3292440bce70484eae"},{"Name":"cp064855.exe","ProductId":"15c5494e659e4865b78e60077bae7860","VersionId":"6fce20ea135b4db1a64e2164c723438e"},{"Name":"cp065084.exe","ProductId":"bba1d0334a5f4b5fbc1a282af5290868","VersionId":"62dc5e8dc509469e808d518e7d1d8f9d"},{"Name":"firmware-system-u45-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"1f91b74faf084255b33a9e102dcf221d","VersionId":"1b95820a5abc4a94bc5151bdc792f5d7"},{"Name":"cp065274.exe","ProductId":"9681dd7da3ad4cfa8b9f5d2fa3efb5ac","VersionId":"5f13811951474126a5c096ee9ec6acff"},{"Name":"qlgc-fastlinq-kmp-default-8.74.6.0_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","VersionId":"e31cd0e58aa644a495b75c3dacb3d5c6"},{"Name":"qlgc-fastlinq-kmp-default-8.74.6.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","VersionId":"e31cd0e58aa644a495b75c3dacb3d5c6"},{"Name":"cp064903.zip","ProductId":"85a59acb7d634eb691745a6c9906ad03","VersionId":"fe0a1d7408354dc58ff1d13feaf02324"},{"Name":"kmod-hp-ixgbe-5.22.25-1.rhel9u5.x86_64.rpm","ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","VersionId":"150fe52eb75d494da70a129e75f16e63"},{"Name":"kmod-hp-ixgbe-5.22.25-1.rhel9u4.x86_64.rpm","ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","VersionId":"150fe52eb75d494da70a129e75f16e63"},{"Name":"cp065085.exe","ProductId":"5d8c4ca5e9ce4b8ab296e754f4544502","VersionId":"19f19c66bfec4a3c8005e3d4506f8f14"},{"Name":"elx-lpfc-kmp-default-14.4.473.24_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"cf36f8009ed4464f93a208bf9c35b47b","VersionId":"bbde0afedb0c4c1095cfce2f5b2b2527"},{"Name":"firmware-hdd-805abb7e9c-85032G00-11.1.x86_64.rpm","ProductId":"f4d3c3f0b12d4c1da09c3d11188e06cf","VersionId":"7feb2261c8eb4f31b117addcbfaf153b"},{"Name":"cp067160.exe","ProductId":"8bfd6c84c6a049339ae439f038925df1","VersionId":"ce40944e526a4e0a9170988b76af587a"},{"Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","ProductId":"953566d3c1ab4efe9b762b361100a259","VersionId":"4412e3e7c98649b3bd32cc53ac661f12"},{"Name":"cp064585.exe","ProductId":"624ecf606d7d4d2c94cae219a5491b9e","VersionId":"d1dddee027b34405847b0900c621181d"},{"Name":"cp064865.exe","ProductId":"308794285e444711a0eb3833d54eb10e","VersionId":"08598475db86417ebc7f27be3c58cddb"},{"Name":"firmware-hdd-020fc874ad-HPD3-2.1.x86_64.rpm","ProductId":"dd0182917bf14543bf436162a2a05331","VersionId":"271d84d3d5984385bdf27d26a6cf2848"},{"Name":"cp062924.zip","ProductId":"93312d51d8f7459ba48a2a8cbf6722a2","VersionId":"4504b100d29c416ab225d299c2a646cc"},{"Name":"16_35_4506-MCX515A-CCA_HPE_Ax.pldm.fwpkg","ProductId":"96fe9c5a9b9741d5bcf4ae73623359e0","VersionId":"49f2e767ba6342678d0b40e538791173"},{"Name":"firmware-hdd-059b8654a6-HPG5-4.1.x86_64.rpm","ProductId":"ae7662457b594bb08733bceba6635c72","VersionId":"a2169e0248ae43efb588a8ff1cda63ac"},{"Name":"CP066010.zip","ProductId":"628a576c95694de3aab72daab877bb47","VersionId":"6025ac4d83194e2c9c1ebd2935c8df60"},{"Name":"HPE_MR416i-p_Gen10P_52.32.3-6118_A.fwpkg","ProductId":"3f857d7b01734aa494f8146516002d2e","VersionId":"35ac0112a59d4a3abf760d6d81afef11"},{"Name":"cp064860.exe","ProductId":"8a01a8f2913f46979fa6206b3faeb0eb","VersionId":"fa2b788e154f4502b57b29aa07a1201d"},{"Name":"kmod-netxtreme2-7.15.24-1.rhel9u4.x86_64.rpm","ProductId":"81cb1e1fa07441fc9994562f591c5c30","VersionId":"a0bbb83802fd4a7288e29c12e08a28c4"},{"Name":"kmod-netxtreme2-7.15.24-5.rhel9u5.x86_64.rpm","ProductId":"81cb1e1fa07441fc9994562f591c5c30","VersionId":"a0bbb83802fd4a7288e29c12e08a28c4"},{"Name":"firmware-hdd-a07a420ed1-HPD5-5.1.x86_64.rpm","ProductId":"f12cb892007944f694736d03ec00543c","VersionId":"2ec04dc8ea434c5ba27ba4f3f78884ed"},{"Name":"cp062883.exe","ProductId":"b81956d2c370432aad5ffc0ea6fc40b3","VersionId":"fb72cae827014ad78019d52dc3356f9e"},{"Name":"CP066649.zip","ProductId":"96d916494e7148b08fda3030539ce372","VersionId":"b028e57912074629a95b12ed19622619"},{"Name":"firmware-hdd-42aff4675b-HPD4-3.1.x86_64.rpm","ProductId":"74085bfad3ea4badb1e5c0235f47c1ea","VersionId":"1244430680b445fa915dfe402d412f3c"},{"Name":"cp064828.zip","ProductId":"0300daf553df4e699178bc1f12267a1f","VersionId":"a826f60ad51b480486995629f48b6cbb"},{"Name":"CP066424.zip","ProductId":"f61d4171b71b4f16a99210ceeba911f6","VersionId":"b2b8ad87726c498cbbe23394855509e4"},{"Name":"cp066653.exe","ProductId":"b0150fa8c3c74fa8a3415a136a3cc117","VersionId":"69093a77f0cc4164a8217c19b9fc1d64"},{"Name":"cp064342.zip","ProductId":"d93273aa12774694887dc3aab21ae996","VersionId":"92ac4b046410404b80844efdf8efdaea"},{"Name":"firmware-system-u39-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"25afa565c5cd4e359629eee44baf7e64","VersionId":"832e2c91e3024c15a15f6477ba86a75f"},{"Name":"CP065988.zip","ProductId":"640faf1092b548cf896ce4ae4d6b3ae8","VersionId":"dcbbdacfef1b408abd0ae116f7420620"},{"Name":"kmod-hp-i40e-2.27.8-1.rhel9u5.x86_64.rpm","ProductId":"2180429b88ed4e24883a75dbd70724b0","VersionId":"9dcd10fb337949639b128009ac1f4133"},{"Name":"kmod-hp-i40e-2.27.8-1.rhel9u4.x86_64.rpm","ProductId":"2180429b88ed4e24883a75dbd70724b0","VersionId":"9dcd10fb337949639b128009ac1f4133"},{"Name":"SC_DL20GEN10Plus_ME_06.00.03.700.fwpkg","ProductId":"9a8025d60954436ba6fa5cef6da3dd18","VersionId":"45b94a781129401299ae3ce0df36f8e4"},{"Name":"cp064861.exe","ProductId":"cd81ec29d7e54f55ab77712a180c1fe2","VersionId":"9d059727aa5c4643b637622d0406d773"},{"Name":"firmware-hdd-852266afdf-HPD5-8.1.x86_64.rpm","ProductId":"5525dd3ac4024adeb1f8ec72b9fd1236","VersionId":"0e1830cb53054b61ac6112a3f7838f89"},{"Name":"firmware-d8000-0130-9.1.x86_64.rpm","ProductId":"a2d50341a55d404a82473ce007636a93","VersionId":"f763fc68bfcb4abea8c4932b8e938820"},{"Name":"cp065368.exe","ProductId":"17666522baed46e695f28d4315d6fdb8","VersionId":"4f9a2618ea174fa2846d628e738c8f12"},{"Name":"CP066023.zip","ProductId":"a4fb8dc02faf478a85519ccf77530c6a","VersionId":"3517de8f98024d459a4a29c680e11ef7"},{"Name":"CP065989.zip","ProductId":"a9e8e46bd6de460ea736a9be4499f26a","VersionId":"81d8c5b2beeb482ba3508dee74c64ae1"},{"Name":"cp067608.exe","ProductId":"77057f17d85c42018e33e3454cf6ece5","VersionId":"85d295ce776b4eeea7d3d3f86175e6ab"},{"Name":"firmware-hdd-68b12e54d2-HPG6-13.1.x86_64.rpm","ProductId":"c41c6d23d08b454ca2ee1c24f966683f","VersionId":"9b39620d09c64ffa884ea81d739d9952"},{"Name":"cp064856.exe","ProductId":"459b31cbafbe408eaf0a96421248c984","VersionId":"5beba73de79140f3a2f4db85642d1486"},{"Name":"cp065379.exe","ProductId":"683278c3722a411eb75e30e9eb4f543d","VersionId":"6d6ab4055aee4b8e9f7e05bd4f0e0671"},{"Name":"SC_ML30GEN10Plus_ME_06.00.03.700.fwpkg","ProductId":"896b673e61904db68a62db4c589536af","VersionId":"feccfbec705146c1bd7c4df6f00de744"},{"Name":"firmware-hdd-6fc985bd3b-GPK7-8.1.x86_64.rpm","ProductId":"2e5a37814cc1401a951db2b5be91b6b3","VersionId":"a339eb95e85748fab0c7ea97b45b345c"},{"Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","ProductId":"7cb9f47fb1de402da9399ef94a8426a5","VersionId":"6927e5439b7746e3bda2359045abc5bb"},{"Name":"cp065292.exe","ProductId":"8bf9eb4134cf48c2a7da72633124722f","VersionId":"444ada6a3b8a405f83a72b466c583f05"},{"Name":"U39_3.50_04_17_2025.fwpkg","ProductId":"5410a19b6b464f26bd8935266bc1120d","VersionId":"2dbdccfe63fa4fd7b69a8b6f21d37159"},{"Name":"firmware-nic-qlogic-flq-1.25.0-1.1.x86_64.rpm","ProductId":"a2c850b33a31462c8693efedafbdd8b9","VersionId":"07e3ad2fd19e4089b75a0d065c01fba9"},{"Name":"cp064706.zip","ProductId":"c9a566daebdb4bd4a0f22d28877b9f3b","VersionId":"5b72663a36ec4ac2a8e3084a2ac63e87"},{"Name":"firmware-hdd-c566d63ca0-HPG7-5.1.x86_64.rpm","ProductId":"c6a4f7a1c0f14173802a4263b3ee7551","VersionId":"1576a5d37927409fb8a4ff16f3f8236f"},{"Name":"firmware-hdd-8173816d98-HPD3-4.1.x86_64.rpm","ProductId":"6ee949809c8346d9b5134787ab827a8a","VersionId":"1455fcb709f34d93987be8eb07076918"},{"Name":"netxtreme2-kmp-default-7.15.24_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"eafab624995d485096ba1119b617b464","VersionId":"d1db23105b874af7ae5e98a35c480f4c"},{"Name":"netxtreme2-kmp-default-7.15.24_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"eafab624995d485096ba1119b617b464","VersionId":"d1db23105b874af7ae5e98a35c480f4c"},{"Name":"cp066623.exe","ProductId":"ed7a5d4d2f9c4a55ba7dea78369f1389","VersionId":"847f832b27f24345ac1b3066536972b8"},{"Name":"U43_3.60_05_16_2025.fwpkg","ProductId":"b64e2e4187274c5798b3aa127c50ba6a","VersionId":"11158899605f45818d289f127fdc6b83"},{"Name":"cp064826.zip","ProductId":"4899e6b54e3941a4b9c3090a539cf6db","VersionId":"6e6378231c4a4296811558adc81021ec"},{"Name":"firmware-hdd-3d97759111-HPDB-3.1.x86_64.rpm","ProductId":"eca7d77c8ba84ffe9014dfb5c3b6ee15","VersionId":"428ced0638264cb2b4d5c1e002477e97"},{"Name":"cp066426.exe","ProductId":"bc3fe657ed304b17aeeab14dfddb1656","VersionId":"006b6cc785d24386a71a557cafff41a1"},{"Name":"kmod-megaraid_sas-07.732.03.00_rhel9u4-1.x86_64.rpm","ProductId":"8796bf21e8204a0da4179cfbcd105e85","VersionId":"a1c14ed9dbe14eae9f68734b59f20e91"},{"Name":"kmod-megaraid_sas-07.732.03.00_rhel9u5-1.x86_64.rpm","ProductId":"8796bf21e8204a0da4179cfbcd105e85","VersionId":"a1c14ed9dbe14eae9f68734b59f20e91"},{"Name":"cp067638.exe","ProductId":"635ad6621b8d4c52b8b9de3325345e84","VersionId":"a73b64edfb434afe9def346412dd9d10"},{"Name":"firmware-dl20ml30gen10sps-05.01.05.005-1.1.x86_64.rpm","ProductId":"e9b531c475a54ce6b287402b5c425933","VersionId":"8c22f1bdc3114f7e81eb9185eedc1670"},{"Name":"cp065076.exe","ProductId":"9141b4ee76c74b70a4eb2f021bfa217f","VersionId":"9c3866d8a0c644ed9881effe46ffeb86"},{"Name":"CP065973.zip","ProductId":"23ed237c56c047b39f75b9977e930a45","VersionId":"442b737a911c4ce88402c62648838ae7"},{"Name":"CP065998.zip","ProductId":"58058fc7c39a49caa2844dbe139ab3f9","VersionId":"c83fb7f18f7b47368698ae0eac6d60fe"},{"Name":"CP065991.zip","ProductId":"eaadba373a2b4b7ab82c00e6e1f55628","VersionId":"ba3b6d5b24a24394ab8fb7f685fa7394"},{"Name":"cp065041.exe","ProductId":"01713b1febed4cc9a463023eeb2cf6ee","VersionId":"597fc3fbe51c4388b19cf861aaccc587"},{"Name":"cp066432.exe","ProductId":"33474bdb31ec42199bc00637b81a4d15","VersionId":"2c4a7e04c81c4328b73f692985c83551"},{"Name":"A47_3.72_05_16_2025.fwpkg","ProductId":"74593c8509e24398998a42d78a910462","VersionId":"5af2d32446844d94a1c48bb40a6accc1"},{"Name":"firmware-hdd-a27c95663d-HPK6-4.1.x86_64.rpm","ProductId":"19d0fae1d2d44133a57fe6d71c8af4b7","VersionId":"b86880ab06934af1ae10a1cd6b78b20f"},{"Name":"firmware-nic-mellanox-eth-only-mft-1.0.7-1.1.x86_64.rpm","ProductId":"35cb34a457a347fd86df4f560cf6cf57","VersionId":"66f62624866e416e986ba16ccdc609f8"},{"Name":"20_43_2566-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"da435657efe64ff1a664870254b46a1c","VersionId":"34fc42ff9f0545c7989842ba1700df27"},{"Name":"cp065383.zip","ProductId":"adefe97a484140f28ccdb1e9dfb3903c","VersionId":"2e806e2923d446a290f0491501b7ccac"},{"Name":"firmware-hdd-017797f12e-HPD4-5.1.x86_64.rpm","ProductId":"ba1b35ce71154e9e8335778f038c2885","VersionId":"05b8b1096d3d4808b9d24df13c3bfa9f"},{"Name":"CP065959.zip","ProductId":"f7d7f54393d44f66845199e26d4e5900","VersionId":"fd33709a37f14aa89a16abbab2f77522"},{"Name":"CP065967.zip","ProductId":"86420e4b9b414e61bd5c2f06d883ac98","VersionId":"737efac29c31429aac77c94f3b7974df"},{"Name":"CP065980.zip","ProductId":"31f49e59526b43cb994f293d4205e9e6","VersionId":"feef26afe3244381aacf3ac21b08abbc"},{"Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","ProductId":"a77901ff235c43f18df58616eefb654e","VersionId":"7319fd82a07c4804b3f42bdb8e099c29"},{"Name":"CP066011.zip","ProductId":"3fa689b1e0c54064af40f5128fac0e5b","VersionId":"6fcc9abfdf734302bb9d64b076e28505"},{"Name":"firmware-hdd-4fbb6d96e5-HPG2-4.1.x86_64.rpm","ProductId":"f18fb22c5eab4952b3cc28771ba83857","VersionId":"6256b3099da14719a16230cd666e0945"},{"Name":"firmware-d3000-6.00-8.1.x86_64.rpm","ProductId":"de51682518bb48a2bb985003f8a8df4e","VersionId":"a928806887974621a6ecdffc37ec5b38"},{"Name":"firmware-system-u34-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"0fb6a42a8b224caba8a145e0ac696d52","VersionId":"c98233b3e5b5465bb61b4751f26aae30"},{"Name":"fibreutils-4.2-1_rhel.x86_64.rpm","ProductId":"C8691","VersionId":"44f35ee909f34a5184b0e66a309de883"},{"Name":"cp064823.exe","ProductId":"e8f02987fae14861a37eb27a43adf117","VersionId":"ea9ce03e8926458692d01e4b7aafc058"},{"Name":"firmware-system-a43-3.72_2025_05_16-1.1.x86_64.rpm","ProductId":"be8e1065c14f4a6883e7804dae8c691e","VersionId":"08fe6a18f06e47fd86134f67f9fc3e94"},{"Name":"cp065048.exe","ProductId":"3f2f70c223354bc6b59b77123faa8545","VersionId":"07a2bdf1f2614bdead26a08fcae71aa8"},{"Name":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.fwpkg","ProductId":"5d636f95f482471a9bd020c928d3b4af","VersionId":"af9c7b4012e74690936756078f1b7f4b"},{"Name":"HPE_E810_XXVDA2_SD_4p71_PLDMoMCTP_80020038.fwpkg","ProductId":"0134d053d49b43b1add04e5a51f6ff18","VersionId":"9dd38770e56547dc9630942d5edd3fc0"},{"Name":"cp065098.exe","ProductId":"8e8fd25144334177930f2db95d492320","VersionId":"932ac9bc70af480aa380dc7f288cb322"},{"Name":"cp067153.exe","ProductId":"f25420df1f7142d3a5eccbf213f27251","VersionId":"a62f840a807641dcb200be80b5454887"},{"Name":"firmware-hdd-b78255e146-HPG8-6.1.x86_64.rpm","ProductId":"03a1d5d1c9c84f2b9c715674a729ac00","VersionId":"e9726d1c16fd4a5abf1aa6bad71d9775"},{"Name":"CP065983.zip","ProductId":"3fba85b34f854c9b9b5bb51030ba5e41","VersionId":"22eb5327aa084ebaa74d6463bbe06c9d"},{"Name":"cp064876.exe","ProductId":"912bdc2895264227ab4d6d2895102ac1","VersionId":"c9ac5ee291d045c1b384fcd49ca0c585"},{"Name":"cp064819.exe","ProductId":"3126d8d47de5417a878b30ed83f0673f","VersionId":"0875ab20031a4bbc8c9ada07ca0c52fe"},{"Name":"cp065267.exe","ProductId":"0b5ea35199d249309413cdf1ab404c23","VersionId":"ae3e0d5a8d104784ac0a8346ce6b11d6"},{"Name":"cp065063.exe","ProductId":"182450d5bced417a85db3271254808a7","VersionId":"56db2b4037ff4a1397ea10e3733b8a0a"},{"Name":"CP064334.zip","ProductId":"03d55b6f216746b88ddef311b0a8c1f9","VersionId":"bd85de99f5db486e935b9e5b89d776e7"},{"Name":"firmware-system-u33-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"dea19449209743ffa1d2262e07eafb25","VersionId":"d7d38b9567034a38b2b8bfb6ca6f16d4"},{"Name":"cp060554.exe","ProductId":"e0019db6f6e24588a441b6cb4e743087","VersionId":"fb8b975529bf4ee68a06d176cb2f9251"},{"Name":"U33_3.50_04_17_2025.fwpkg","ProductId":"972a94402aa14188aa7633893c7137b6","VersionId":"b77233ce1f044d458c15b1da70368422"},{"Name":"firmware-system-u56-2.42_2025_06_13-1.1.x86_64.rpm","ProductId":"d04d5f721c2f4e7798db0b91a4b31687","VersionId":"25702fda728e4e2bac1bc885d146af15"},{"Name":"cp065067.exe","ProductId":"c65e02b4990e43eea4fa2402b45960eb","VersionId":"10accc483b4c4a3d8b61217e4b477008"},{"Name":"cp065036.exe","ProductId":"5f5babdc8edb43cda68a851809a46823","VersionId":"dbb6acb2d72740cab9c41198362ab988"},{"Name":"cp066993.exe","ProductId":"8384f9a8878649da8d668b07fb30c48e","VersionId":"02ff1fd529ec4d30aa63cf4a687faabe"},{"Name":"cp065109.exe","ProductId":"094c75ee866a4b1bb6f0e035ac316695","VersionId":"d59712827fd54795991986d325c19e08"},{"Name":"cp067145.exe","ProductId":"f74d125372264713b4a9d8ebea70260d","VersionId":"7458216ea96c458091f5890547228ef5"},{"Name":"firmware-hdd-46fc43ab26-HPD4-15.1.x86_64.rpm","ProductId":"a583c05eda574560bf7c625d7e1d2b1c","VersionId":"fa66cd533976414988d342184574426e"},{"Name":"U40_3.50_04_17_2025.fwpkg","ProductId":"118ba074c4b3495fbd26210e14a17511","VersionId":"ce552811bda54316bdb5d3663a9cc6eb"},{"Name":"mft-4.31.0-149.rhel9u5.x86_64.rpm","ProductId":"d3f65c2e0c364f4bb543e0989cd11684","VersionId":"98c7673e6a94492bb625f537e66eb25b"},{"Name":"kmod-kernel-mft-mlnx-4.31.0-1.rhel9u5.x86_64.rpm","ProductId":"d3f65c2e0c364f4bb543e0989cd11684","VersionId":"98c7673e6a94492bb625f537e66eb25b"},{"Name":"CP065982.zip","ProductId":"8e9f61780275418686c8b0a671e012c9","VersionId":"b140902a90e9402ca1580bc2b9bc489b"},{"Name":"cp065053.exe","ProductId":"ed9a4b98eb61471ab66480b22d4e9c4f","VersionId":"3fe416b8425542d19f0e447a80d18fe1"},{"Name":"cp065042.exe","ProductId":"f1a885eabd844ec18e0dab540c21f1c8","VersionId":"4c7d25dc2717457284e66a55be1650cd"},{"Name":"CP064921.zip","ProductId":"a271f679286141d98830336f93a8205f","VersionId":"5e1fddb843d64cc082b8f2361cbbfb50"},{"Name":"cp066719.exe","ProductId":"3ac61ed209fd49fb908341fa7b77c3ea","VersionId":"51f1e23f43dd4659a09f930bd429a555"},{"Name":"cp063825.exe","ProductId":"07117e80b64248dab9811a2280fcc85e","VersionId":"d3106165864446d5a69fc36f516838b3"},{"Name":"cp066624.exe","ProductId":"41b0e237fef743bfa73e14fb19e3c9ff","VersionId":"58cc68ce8a124b5fae3fb54ba53543b5"},{"Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.fwpkg","ProductId":"29921b6ba8e14e7cbeb3829f2308a0f5","VersionId":"1c44c6db3e5745e5b284a591fdfd7b73"},{"Name":"cp066647.exe","ProductId":"84f4d8cbba034646b75e0fce6c455870","VersionId":"d010bd6c533b4e2492e6f02b08d461f8"},{"Name":"CP065945.zip","ProductId":"738515ca087c45c4b01b62883007bfb8","VersionId":"0e038dbf393b4835a98f9e12bce3c8cc"},{"Name":"kmod-tg3-3.139t-1.rhel9u4.x86_64.rpm","ProductId":"dcff0c4699e341cf85f18eb94d85147c","VersionId":"d4762f8792f7437691b4a94ca92e4b53"},{"Name":"kmod-tg3-3.139t-1.rhel9u5.x86_64.rpm","ProductId":"dcff0c4699e341cf85f18eb94d85147c","VersionId":"d4762f8792f7437691b4a94ca92e4b53"},{"Name":"CP065963.zip","ProductId":"486d4489346f4ec8a160ad4ef3c94f99","VersionId":"bf355ff43d0c4e5d9f258788f8b3e569"},{"Name":"cp065037.exe","ProductId":"ae8b95207bc948489c851dd62c16f373","VersionId":"a11e2bedefd24f7380ad6b2cf91d1ae3"},{"Name":"cp065456.zip","ProductId":"fade5b11c713406a8e9c5f691c073fe5","VersionId":"522048d661c74fd699506db4f11012b7"},{"Name":"cp065135.exe","ProductId":"a8ea930bfde1449ab4444eb61f65be31","VersionId":"770cbad3ff784b42b93a628974b5111f"},{"Name":"kernel-mft-mlnx-kmp-default-4.31.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"01cbc1be755b4243b92be8c9339313eb","VersionId":"404e925237794c40bbd77e8873857543"},{"Name":"mft-4.31.0-149.sles15sp6.x86_64.rpm","ProductId":"01cbc1be755b4243b92be8c9339313eb","VersionId":"404e925237794c40bbd77e8873857543"},{"Name":"cp065058.exe","ProductId":"2b0745f5d1b9423aa88e57ad4cdfbe00","VersionId":"1f2a2fd82b404d3cb31676729643b96d"},{"Name":"U37_3.50_04_17_2025.fwpkg","ProductId":"644b370c36714c6490fce699ffce22e9","VersionId":"d74e675b753a490b9e4ceccdc57c7424"},{"Name":"cp065298.exe","ProductId":"24ef5d7f7f9443c598148daa0f16246b","VersionId":"373d0c6dcdec4a6daacd282f5ff8c003"},{"Name":"firmware-ilo5-3.14-1.1.x86_64.rpm","ProductId":"8aa4f1e30dfc4417885cea85b551314e","VersionId":"ab3fc24fcf8b465592a0f5bea3984e9c"},{"Name":"Kioxia_PM7_KAPM7ALFHPD2.fwpkg","ProductId":"fcbfe734454648628f4d8c3848d7db3e","VersionId":"44f06c437022427688a3626804fd12c6"},{"Name":"SPSGen10_04.01.05.105.fwpkg","ProductId":"c4ff2ade728c42bfb931931df173daf9","VersionId":"c7576705f5fd47e6af7e58ac0c5a4a78"},{"Name":"CP066421.zip","ProductId":"cd60e68416444c61a56b3c63cb2d1ca3","VersionId":"bc82ae4d00c64b929dd7aba43d1870f7"},{"Name":"cp065096.exe","ProductId":"39fa471cea234b3883e794de990ad252","VersionId":"2ec2a66e716b4680bc754489720fd561"},{"Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","ProductId":"5521a7a96ce64d8a92b5aab1a6147b6e","VersionId":"698b806535e54899a0d8cfa4fae3990c"},{"Name":"firmware-hdd-24384980ec-HPD2-3.1.x86_64.rpm","ProductId":"8d0bd1ce26004a9e8191551757cba42d","VersionId":"a26b0a0152b74e779ad1c5913d900e5c"},{"Name":"firmware-hdd-d550523365-HPD3-5.1.x86_64.rpm","ProductId":"d287970503c042a480f1860ec2c054c7","VersionId":"06d8587d6a554ef98b43d02cc7b1ac3a"},{"Name":"CP065984.zip","ProductId":"6a808075e9fa4bc19e7d11fd17511784","VersionId":"85cbb20de5d1424bacf3b788a8ce9163"},{"Name":"cp065378.exe","ProductId":"6510bb61b44e4df589649e5642d32bf1","VersionId":"15f3852d1d8a4a50884b2c308af82ade"},{"Name":"cp066820.exe","ProductId":"2e589cc6a48f40eaa0870785c3351832","VersionId":"fb5c5efa11324bb49502cb4dae49cd6f"},{"Name":"cp065086.exe","ProductId":"75d8486987f7480b8e2a0459e1d59d0e","VersionId":"33c4414c6bcf43e7a41622875654a722"},{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","ProductId":"d1422347af3f4f888596c242a7fdb7a6","VersionId":"67d5b946167f4f989c84ac75fcb085d4"},{"Name":"HPE_E810_XXV4_OCP_4p71_NCSIwPLDMoMCTP_80020035.fwpkg","ProductId":"6adb26c5fc564f219877ab6a448e709b","VersionId":"1e0432b93abb448db3c8a00614e74e53"},{"Name":"cp064859.exe","ProductId":"ffbc55840f92498790e9569c6abb14d8","VersionId":"1a6fceeb80a34f2e9e9988800891cb41"},{"Name":"hponcfg-6.1.0-0.x86_64.rpm","ProductId":"db808d6aa2e24648bcc5e3f46d635b1a","VersionId":"6abdf231475c435c92bb558b96dfc97b"},{"Name":"cp065016.exe","ProductId":"92d9bf17d9ef471e842a80e42a41ec72","VersionId":"1681cbbe4697481384554f9ea69f1896"},{"Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","ProductId":"9797527c9a7541debadf0b96aae4c9b3","VersionId":"9077ed7856b1465a8395a8ce4b5e9a97"},{"Name":"firmware-nic-bcm-open-2.41.0-1.1.x86_64.rpm","ProductId":"110c3bd2bca349b2ba7b9fec9e58ee8d","VersionId":"cdbbe608b00b469b9aebcbf50c83a45b"},{"Name":"CP063098.zip","ProductId":"ac4d46dcda694f51abe34e6378a53487","VersionId":"365827e1ff614a1cb13289323f593ff4"},{"Name":"elx-lpfc-kmp-default-14.4.473.26_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","ProductId":"83fed5e4a427414fb0792283dd57ec37","VersionId":"3f2193e2650146c4aa3a3ff8b1c516b3"},{"Name":"CP065977.zip","ProductId":"a1b0fb5619dd4bf685499171488aaaa2","VersionId":"3997df854d184cccb8bf94004912f89b"},{"Name":"firmware-system-u31-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"f5aa8733027b4498a80cd2e690d91986","VersionId":"4d639e5e4e65458ba7791a6f64b65c08"},{"Name":"cp067682.exe","ProductId":"67fb0d734fd248cca1eff5e7b321a8b6","VersionId":"16ea6f4c880e4feabd7c537e0d7d36d2"},{"Name":"cp063149.zip","ProductId":"eea0fcde2dfe4c0ebeb9ed47ea130474","VersionId":"906179da97054dc693d9224a3452d494"},{"Name":"HPE_SR_Gen10_7.43_A.fwpkg","ProductId":"3d51e7d6b8674f16bd8f67bee278e11a","VersionId":"21b12f17270740e98bc0d546a55c851e"},{"Name":"storcli-007.3210.0000.0000-1.noarch.rpm","ProductId":"0883e4abd7344c9b834b5e5585107933","VersionId":"4dfd7e5af5864f6ea849747f171f690f"},{"Name":"U46_2.42_06_13_2025.fwpkg","ProductId":"d8cf5e47a4564ba6bcb2ea1177a33ff1","VersionId":"6b9f622899434c4285ba9886607fd35f"},{"Name":"firmware-hdd-a9843986b0-HPK3-5.1.x86_64.rpm","ProductId":"cd7426f38f994cdda68f5e95f6cadf0f","VersionId":"3628482546184f4db1d036f891e61189"},{"Name":"firmware-hdd-492a9952f6-HPG5-4.1.x86_64.rpm","ProductId":"fde211973c7e4009ac1207f980953529","VersionId":"e130ff57fb12428e851927460d468897"},{"Name":"firmware-system-u38-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"7ebf7b3b32234babb113c6746f09f68e","VersionId":"88ed60874ab34b78a5d733fdb9632ca1"},{"Name":"firmware-system-u61-2.40_2025_05_16-1.1.x86_64.rpm","ProductId":"e99fcbdfe7054c0191086c267b0b5462","VersionId":"224fa842e50c42a193a21ca70a75102d"},{"Name":"cp067691.exe","ProductId":"21c71338fdf2430b8b41f3737620822c","VersionId":"d9ea672369d74105a09ca946a025357e"},{"Name":"cp067695.exe","ProductId":"bdb6e242313a47b89b69823cf9ad3729","VersionId":"c5f8aab8e5b44d3489812dc34e1945db"},{"Name":"cp067692.exe","ProductId":"957b79699cf847b3bc804b96d1108938","VersionId":"495f8cb1681b441e8b227e05d2fc5892"},{"Name":"firmware-hdd-b04df66fe9-HPD3-3.1.x86_64.rpm","ProductId":"0e486c09859842e29ba327f60bd15f9a","VersionId":"9a1c6d265a394ca9a79b3d9f244b91d0"},{"Name":"CP065933.zip","ProductId":"33bf4058d2284d31ad166fd3619cf008","VersionId":"d0b0db6f4a2548e58abb55a12af0bf2a"},{"Name":"firmware-hdd-a886842a99-HPD2-9.1.x86_64.rpm","ProductId":"9ea83d5d4cdf449690664479d7c8538a","VersionId":"293c2472d0e644839c5bb2975a3779ea"},{"Name":"CP065938.zip","ProductId":"fcc57b2588b04f54a01cb383a7a5a458","VersionId":"221ac2d459d745f6aba61fbb6f98226a"},{"Name":"cp066511.exe","ProductId":"f0e80dda550e422981f666fd854cb6f6","VersionId":"3496fbf9e27e44d29a09b5f37e69a7c7"},{"Name":"cp066634.exe","ProductId":"a3ac88993616476a8dcf9b3fac5ea67c","VersionId":"d80625c54c674329a1f7381d469fbc90"},{"Name":"cp067540.exe","ProductId":"a83500e26a4d4bb89a4eb5821b7b2ca6","VersionId":"ceee48d27fde4103906af6b3f8114b3c"},{"Name":"CP066652.zip","ProductId":"83f19a40734047f1a91d25f9cd465999","VersionId":"0c5266fe33784696817b5c7a558e145d"},{"Name":"firmware-hdd-6b7ce3da0e-HPG2-13.1.x86_64.rpm","ProductId":"05a81ac262384916b1fa6e922a6cada6","VersionId":"2750331d1d3248c3af845c332d0282ff"},{"Name":"firmware-hdd-3496cc4743-HPG3-2.1.x86_64.rpm","ProductId":"f6fccbc5aefd411688310b509bfaeaec","VersionId":"0029a52c5700479b9716d68ba90cb3ac"},{"Name":"CP066633.zip","ProductId":"fdb3892daac8474c8262b342acf8f35f","VersionId":"1ae936910f9e439ca24742f29b3450a6"},{"Name":"cp066628.exe","ProductId":"fd79732b69c747a4ba4278e32ef12a49","VersionId":"8519d4c8f9834637a822cf2eaad01e46"},{"Name":"CP066002.zip","ProductId":"c0403221bbc14b609f9dc339f216be5e","VersionId":"f892951743024df2afb45434cce22ed5"},{"Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","ProductId":"58f3059c65eb403984076353b9f058af","VersionId":"351d50a2bba345ebbd72893c5d1e177f"},{"Name":"firmware-system-a48-3.72_2025_05_16-1.1.x86_64.rpm","ProductId":"1e4f77062f4d48c8906f4212d8016a76","VersionId":"0ed31a17a05440c6a4ecf338acf97e7c"},{"Name":"cp067178.exe","ProductId":"c5181c3bc0654e9db312aa6200639426","VersionId":"1f6144b631ae4a278d4ebeb03344b3ff"},{"Name":"CP067551.zip","ProductId":"11f86ddaaa3742028089d7f3e7f71098","VersionId":"2d3ded14cd644e28b76f26e6532a24fa"},{"Name":"cp065055.exe","ProductId":"96868d9680c84d50b81011a5d4811094","VersionId":"8a6701a03c28432085e481e36d9a1c7e"},{"Name":"firmware-hdd-2c27a7a9a4-HPD2-9.1.x86_64.rpm","ProductId":"188f54d508794fafbb14f21866a0ffb5","VersionId":"0e7b7692d1d246848d45444c7b033df3"},{"Name":"firmware-hdd-8b26d1ef02-HPD2-10.1.x86_64.rpm","ProductId":"596340d3247946aaa109faeb065a7eab","VersionId":"72438aa5f8824af8b15fb3db22e083d7"},{"Name":"CP066427.zip","ProductId":"8bcfdc333663490ba14bb0a7e2286062","VersionId":"21d47f962e094a4c94a38476a164a6b4"},{"Name":"cp065093.exe","ProductId":"4893b899f6404bf4b119e3e3a55be5b2","VersionId":"d7097370e49f4bb0859d4da747fe26b6"},{"Name":"U44_3.60_05_16_2025.fwpkg","ProductId":"f2f901fd357f4c6692fae66dcbbb15ed","VersionId":"58dfcf52b9a746a880d8a51db2b758f9"},{"Name":"firmware-d6020-2.74-21.1.x86_64.rpm","ProductId":"ce7e63b5ed004965a0bc6af06ca584ef","VersionId":"8fbab50fa17e4b9282fec185dd4a95b7"},{"Name":"cp058394.zip","ProductId":"6ac4c1fb52734dc69d27fd9966ff92b4","VersionId":"b596876c814544fe8d905c525a92f4c4"},{"Name":"cp066445.exe","ProductId":"19810cc433a442df903276a4b0c34598","VersionId":"49545129c4364737ade5f3abf92675b5"},{"Name":"firmware-hdd-3815d4b024-GPK7-8.1.x86_64.rpm","ProductId":"990fcc25e986467fbdc6e3aae2e41a2c","VersionId":"5119c79be31943039be66699bbe8887f"},{"Name":"firmware-system-u50-2.42_2025_06_13-1.1.x86_64.rpm","ProductId":"d4e991bf139c45c8a6f5a9b30e1a9d04","VersionId":"5da107b072d149699819b76c0ae59878"},{"Name":"HPE_UBM4_1.24_G.fwpkg","ProductId":"1e88e3b27b814bcdbc8dcf6390d324d1","VersionId":"4e14138c4c714237bcc8bfb333533ccd"},{"Name":"CP065965.zip","ProductId":"6d5cd83fc05f4da0a652797154f87a4c","VersionId":"db3c3447749a47178b07d9d5b2df670b"},{"Name":"firmware-nic-bcm-2.41.0-1.1.x86_64.rpm","ProductId":"1d81dab4bd3149b19db9381601c1abce","VersionId":"dbaad443da764ee7a12d4c995ca78211"},{"Name":"cp066316.zip","ProductId":"98a183458fbc454a86f635797ce90db5","VersionId":"b36a633ff667434295a5dcb82e072da5"},{"Name":"HPE_E810_XXVDA4_FH_4p71_PLDMoMCTP_8002003E.fwpkg","ProductId":"955cffa0d4fe4b76923c0ea7afeca0bf","VersionId":"d8ac3cc8e7004f38a04514ae385d41d7"},{"Name":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","ProductId":"5c10ef42611f4cada08e038ec64fbce6","VersionId":"bc48d0c6a7274ea890d1070742ae9a44"},{"Name":"CP065960.zip","ProductId":"be910528f863487899cf62f353be4a46","VersionId":"1985144b7a1a4fe793768a830390a68d"},{"Name":"CP065966.zip","ProductId":"b6cb1e645c374b3e92e6a0688121990e","VersionId":"1943010e21304beeac6d93db0b65cff5"},{"Name":"firmware-smartarray-1f19a4a64d-5.15-5.1.x86_64.rpm","ProductId":"799e6d2dd6574724a67dc3ea392d2873","VersionId":"5aa7ee386fcc462f98821054e3dbf958"},{"Name":"hp-ixgbevf-kmp-default-4.21.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"58259b45dec7469580dfbddb76171768","VersionId":"85763af19287402f8cd33fde1111c9e1"},{"Name":"hp-ixgbevf-kmp-default-4.21.25_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"58259b45dec7469580dfbddb76171768","VersionId":"85763af19287402f8cd33fde1111c9e1"},{"Name":"CP065944.zip","ProductId":"0b3bbfed90454334ba3331c2f9efa2ea","VersionId":"8c3ce5786422481ca1e335852104a165"},{"Name":"20_43_2566-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","ProductId":"ab42380273374a988dbcb1a25432ed96","VersionId":"c1f85c93b47b4286a27f78fea1b39e1c"},{"Name":"firmware-system-u32-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"ff5a3639b5c744a8ac2e4611ce9482ea","VersionId":"9d74ccf59c994c46acb41b5fc577a603"},{"Name":"20_43_2566-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","ProductId":"6ca4dd262131408db10af90451555128","VersionId":"bac9b9b7601b44fe97018729b37ae673"},{"Name":"cp062918.zip","ProductId":"614a0c688deb4def90dafbe34fab64bb","VersionId":"af871489e60b470ea50404d59023eba9"},{"Name":"bcm233.1.135.7_Thor.pup.fwpkg","ProductId":"14160fbfa3db428fb3e9bea4f7d651a7","VersionId":"3a969920a470448d8f7afc77abc8e19f"},{"Name":"firmware-hdd-12304c1aca-HPG6-5.1.x86_64.rpm","ProductId":"205e86b4ae1e4a28ae1e3cf39faf17ba","VersionId":"b50d6617906e4a4280febde98b9dea4a"},{"Name":"cp066512.exe","ProductId":"0d3c26d8a354471c9de6f3f842c4e5d3","VersionId":"1e6f365e9fd24516a483d8c998d61f49"},{"Name":"firmware-system-u30-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"1368ab3d45fb40b799c33ccbe297c322","VersionId":"80741f6311c84598ae917b5b79cd7a58"},{"Name":"cp065277.exe","ProductId":"1607ed48320345de80b2a91bfe782685","VersionId":"beed53fc6cfa409f93be5a9d64c1b49b"},{"Name":"CP067635.zip","ProductId":"bd2780f798b64cefbb3916c847ffd755","VersionId":"ecce612137054aeb911de79c65c4dce6"},{"Name":"CP065925.zip","ProductId":"a5e366733eda432d8665f3d8aaa40d56","VersionId":"0d29c281641d41adbcbc3c3426d12e2a"},{"Name":"firmware-dl20gen10plus_me-06.00.03.700-2.1.x86_64.rpm","ProductId":"c165fa12d9644f82b813c7e585ce9181","VersionId":"d9e9b9d9233d45dd9d1c27327a85f47d"},{"Name":"cp065083.exe","ProductId":"17203fd912204cbc96571639dbe02ea0","VersionId":"30265f975a514468aa7df3085907daef"},{"Name":"firmware-hdd-d7af557f47-HPD4-10.1.x86_64.rpm","ProductId":"f1e144df7ff3445292cda5ea1ed9d30c","VersionId":"cb83a1ddc2cc43fe98b70c610fbf6488"},{"Name":"CP065975.zip","ProductId":"ae4ca58542c143b088e01d17c537b7ac","VersionId":"add09b8f197e457aa7e56438d589784e"},{"Name":"hp-i40e-kmp-default-2.27.8_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"7204c0f5c514445a87ae5a6c742f6a37","VersionId":"cdf5541730b840b9ab59c0dda22f9d4c"},{"Name":"hp-i40e-kmp-default-2.27.8_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"7204c0f5c514445a87ae5a6c742f6a37","VersionId":"cdf5541730b840b9ab59c0dda22f9d4c"},{"Name":"cp063482.exe","ProductId":"d217387da75b452f91f63bc9a4605e37","VersionId":"bffcafc491a54117afdc65f7e42d19f4"},{"Name":"cp067693.exe","ProductId":"2ea9059fa42b417a890b2c9927375976","VersionId":"a48d92cf9e3e4012953c44487bbac75e"},{"Name":"PICGen10-1.1.4-1.fwpkg","ProductId":"fae7c963a551489594d913b81c29f2a4","VersionId":"84e80a3fb2e04c93b20e3b09f3a5d3c5"},{"Name":"firmware-system-a47-3.72_2025_05_16-1.1.x86_64.rpm","ProductId":"4a7391c65f0b46d485ea7105b1cfb339","VersionId":"f8bdb2afe8944600ab6d203f3868197f"},{"Name":"CP065990.zip","ProductId":"a6447acbde7f4368991a3df1503f91e8","VersionId":"b4d49336f3f94c119afb40b5f43eca2c"},{"Name":"cp062903.exe","ProductId":"7f5cc2735e814d67a516e6e72cb03eec","VersionId":"01e6000ed7444b49b810f2c4cd99e9ae"},{"Name":"CP065947.zip","ProductId":"2232e2b621a84f55a544f2a4ed765213","VersionId":"d9ce784d3c6446d0a0b58f1fc7bafd70"},{"Name":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","ProductId":"066920f0b4684f1da260602d0174d2e0","VersionId":"4b658756c8a14d80ba2c6e5ea4f3a675"},{"Name":"firmware-nic-is-intel-1.33.1-1.1.x86_64.rpm","ProductId":"eeaaff922a754e178b46a3315fd0a64a","VersionId":"8538d863e08a47bfb4d3e9824e0a0063"},{"Name":"firmware-hdd-f6d00bd17e-HPD4-9.1.x86_64.rpm","ProductId":"07fc1a5a961a427ba3c2e3f341d3886e","VersionId":"ed44c8cba8ea4ffab04a2335b4f04ba8"},{"Name":"cp065110.exe","ProductId":"8c2329b4625b415f9c19a0c86db985e1","VersionId":"70f037ccb8724ef2a09588a240ba531d"},{"Name":"cp064818.exe","ProductId":"7dd14e7585784238bb6caec32dcf1d80","VersionId":"d183dd9665a64420ad8ba66a86f6c228"},{"Name":"CP065937.zip","ProductId":"25298d41e8ae4c7a847f78be945ec24d","VersionId":"56af69663070424fa03eafdf58f6e6c8"},{"Name":"cp066792.exe","ProductId":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","VersionId":"8a194b62ea93443eae46eb94f16d2499"},{"Name":"firmware-system-u46-2.42_2025_06_13-1.1.x86_64.rpm","ProductId":"4eb73551b4784537817e4ada8a1d49b5","VersionId":"57d616ab59734d38a810559a378032d8"},{"Name":"HPE_UBM3_1.24_G.fwpkg","ProductId":"df57af7543b34ffbb722ca05255bf445","VersionId":"bc8e3b1eb8804b47acb76ad46bb94011"},{"Name":"cp063824.exe","ProductId":"ad60a281882240318ac9ec3091a5f1c9","VersionId":"129ddc7e30ab490f8b8e88f881a621a8"},{"Name":"U30_3.50_04_17_2025.fwpkg","ProductId":"ab0976902eae4e0c8757219b825c91f8","VersionId":"4f2396465de44ba1bb72115f84686416"},{"Name":"ssa-6.45-8.0.x86_64.rpm","ProductId":"39676e9bd8d74e11b8837e3f6ebabd5c","VersionId":"41e56d2c7b2640a5b8badcd4805266a1"},{"Name":"cp066646.exe","ProductId":"b9a8e50fea15459f9f236f2538fb4a07","VersionId":"d7886760f2ec4d57ac33319cfffefdbb"},{"Name":"cp066768.exe","ProductId":"d626b04e2b74450287a682c2c77ab027","VersionId":"fdae3bbea9de4de882e12596df49314f"},{"Name":"cp064439.zip","ProductId":"e01aaedc1c6c4e4090054a22e89562d4","VersionId":"9ec5fb420b6c4a50a324b7f40033231c"},{"Name":"Seagate_CimarronBP_SCIMARBPNTG2.fwpkg","ProductId":"799a5476ba934d049a4150e04e75c398","VersionId":"294d1ba482314731a5db35592e3627b4"},{"Name":"smartpqi-kmp-default-2.1.32-035.sles15sp5.x86_64.rpm","ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","VersionId":"be68ec00d6144462901a91948dc61da7"},{"Name":"smartpqi-kmp-default-2.1.32-035.sles15sp6.x86_64.rpm","ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","VersionId":"be68ec00d6144462901a91948dc61da7"},{"Name":"cp063826.exe","ProductId":"954c63f35d4743b2b629b5d17bfd860b","VersionId":"db79dc860db94739ac7968363bd13855"},{"Name":"cp065272.exe","ProductId":"794cbcecc16344ce8539a9b80f70c157","VersionId":"4983bc70954c46fbb5ce9a8ab5e55fe1"},{"Name":"cp065074.exe","ProductId":"9c9f3096a89f4cc7b4a9b97b01822036","VersionId":"8f8d35b9c5674dff9154000ae4de695f"},{"Name":"U41_3.50_04_17_2025.fwpkg","ProductId":"2b44e5307a9948769c51d6ac1f276915","VersionId":"2be5b7c841f04aadb30e1b5e0a46421e"},{"Name":"cp066951.exe","ProductId":"cdb3eb30e49445858807ae13ca01829a","VersionId":"7a94918d937b400e8695b27c0481e3cc"},{"Name":"cp065097.exe","ProductId":"3f71b29f23c14fcb8f1f4cc9ac53400c","VersionId":"efe35f9e51fb4c2a83e28ebae4c00768"},{"Name":"CP065981.zip","ProductId":"fc28c0050f9d4a8a94e83f990b230b39","VersionId":"9a01125032cc4fc29a1ae86c40a9dcb1"},{"Name":"cp064857.exe","ProductId":"ab6756bde612475998d62d4bbb8717ff","VersionId":"30bb7173e96d49f3b38ba838938f3aba"},{"Name":"CP065264.zip","ProductId":"79ba405b8c19425aa9a14902b672b652","VersionId":"eabd17051aeb441882915696b7480ff1"},{"Name":"CP066000.zip","ProductId":"070f2ccb66ec4478ba85a2e3d9712434","VersionId":"d3127bf38a094ef284bcda3b9b102157"},{"Name":"CP065939.zip","ProductId":"d54c971d2c3047569ed2e37939cd2848","VersionId":"c510b3b7041e47f49b7d1a76cb4bb0d0"},{"Name":"Seagate_CimarronBP_SCIMARBPETG2.fwpkg","ProductId":"e0d3905a13b74f06a63b96091e3a0b13","VersionId":"25de70d01b804e29a5efa959dff10893"},{"Name":"firmware-iegen10plus-1.0.0.22-7.1.x86_64.rpm","ProductId":"03c87662bb3a4a57a852807a8f77de3f","VersionId":"641ecd5e784e4b4da46db0c36bd221c2"},{"Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","ProductId":"6f38004b166d42068a292e455179565f","VersionId":"8ae279136d1146d9a07e0ced51a7a9cd"},{"Name":"firmware-hdd-54addf5312-HPK3-16.1.x86_64.rpm","ProductId":"3d004333c656491289fdf09d5881fcdd","VersionId":"a7dd9c9752714e15804cbe32077f1145"},{"Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1.x86_64.rpm","ProductId":"dcf87aae93de4d649fef4547bffe751a","VersionId":"7dd0435c32a34e52a0679169b72dff45"},{"Name":"firmware-hdd-fa46c607d6-HPD5-6.1.x86_64.rpm","ProductId":"aedaa041caed4345872545de3f1efa40","VersionId":"e4664ce7c3474991a0aa149dbbfcffa1"},{"Name":"firmware-system-u40-3.50_2025_04_17-2.1.x86_64.rpm","ProductId":"672edcd2af9a4bd18876e5e3192cd831","VersionId":"389edd02a33740e8b575db43724c61eb"},{"Name":"Micron_7450_Micron_7450_M7450ALLHPS3.fwpkg","ProductId":"5b36200ffa3640839369c39ca58c8134","VersionId":"be4575b6b0d64fc097f43ac471267831"},{"Name":"cp065025.exe","ProductId":"057a33153b064c9280dd7da9d3d5a47a","VersionId":"0f9c20ff191f45069b5cd7ae80081d14"},{"Name":"U38_3.50_04_17_2025.fwpkg","ProductId":"703e98acf33d484a9d2825573e86e8c0","VersionId":"0948e29c810e408f8db77388212bcaeb"},{"Name":"sut-6.2.0-9.linux.x86_64.rpm","ProductId":"b3a8e7e2c4ea466a9b404955f474449e","VersionId":"cbdb18339b7f4044ab2b1a0bba104d6e"},{"Name":"CP065935.zip","ProductId":"72ce2dc2a1214941a11d7ccaace19196","VersionId":"5f220474c8eb42dc950cba5f2954ae24"},{"Name":"CP065940.zip","ProductId":"8a5f6b85a2a94dc58e5d42c516c7060a","VersionId":"6b0b91b47e2f4d9189480894f7b1ba61"},{"Name":"cp066450.exe","ProductId":"b2dec2e98a4f489c96311517a4bf5571","VersionId":"96a211c9133b46ef81e135cbfa01d5a8"},{"Name":"HPE_E810_XXV4T_O_SEC_4p71_PLDMoMCTP_8002003A.fwpkg","ProductId":"6a4f9209b5474891beaf50886f41470e","VersionId":"8771d53514e24352bb0b3a48756da845"},{"Name":"cp065620.exe","ProductId":"4e3802b484324394ada6924af481323b","VersionId":"4af7309fa65f466d8f6f5288f4ba82a7"},{"Name":"HPE_UBM1_1.46_B.fwpkg","ProductId":"a4ccd8709d044858ab5bf64233046176","VersionId":"a663f1f50ce245ec806abddbf83cd919"},{"Name":"cp066429.exe","ProductId":"6c76dfc1e26441a48559e0f1bee2891e","VersionId":"70986e1a9f7349b2945b7eec42f43797"},{"Name":"Seagate_Summit_SUMMITSUSND1.fwpkg","ProductId":"d0bba068f7ca4e978bcc6d2bf9e8abf7","VersionId":"b9f6360d167c40e3b43a633519b19ce3"},{"Name":"firmware-hdd-8d68452816-HPD8-6.1.x86_64.rpm","ProductId":"6f10e85c0a8e4d0f99dcb8584f535fd3","VersionId":"6c8d6b7797334eaaa502bcaeec4e4cac"},{"Name":"CP065999.zip","ProductId":"809cff8704ac44759685c033bb7b76d3","VersionId":"fb0ba8f67f8f42d3ba9f214d072fe390"},{"Name":"cp065582.exe","ProductId":"6522bf51105244bfa55540a1e824854d","VersionId":"9b98028398924bcd9dbf622b9fa4b86c"},{"Name":"cp064337.exe","ProductId":"8484f11834644aea8a2a14d1d0d58403","VersionId":"255c9aae8aa540dd8a906a5a449031e4"},{"Name":"CP065946.zip","ProductId":"65980a419afd45d6b2067bb6166a4282","VersionId":"a0bbf3db79104da6bc975c6db1959f9d"},{"Name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","ProductId":"63a556e6179b4101ae6472eac493f29b","VersionId":"ff883fa218c0497fa594f3cddcc1925c"},{"Name":"CP065950.zip","ProductId":"7004592a3bf74fab99a6fe756662ebbc","VersionId":"5cc55e8f72054302a6d1bd6d2b2ec798"},{"Name":"Samsung_PM9A3_PM9A3M2HPK3.fwpkg","ProductId":"3d4b3948a2e7454589365f36eee4d988","VersionId":"3bf954c2f143454a838399358e12d303"},{"Name":"cp066807.exe","ProductId":"169b01f1c4c245bc854a8424af9a5f85","VersionId":"add6864c09a343f5bc05b5ba4cc7815c"},{"Name":"CP065969.zip","ProductId":"7d855090560e4f85994eaba25e5477a5","VersionId":"0f84dd3049c040b6bc5ce806d58746c4"},{"Name":"firmware-hdd-35fd24601f-HPD5-5.1.x86_64.rpm","ProductId":"c4ef0470aa934a20948f1a88d8eff26d","VersionId":"f1052c1e2d8d44e28000054f6b96a70d"},{"Name":"amsd-4.2.0-2039.3.rhel9.x86_64.rpm","ProductId":"6e4df08455db4ce3a3b07b6eecea6280","VersionId":"65b3210176a04631ab54616a634c61fc"},{"Name":"mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm","ProductId":"58dd146b67a34b2492cfd64a1feceec4","VersionId":"5a6d6c86169c491eb37ef2f9cda46a1b"},{"Name":"mlnx-ofa_kernel-kmp-default-25.01_k6.4.0_150600.21-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm","ProductId":"58dd146b67a34b2492cfd64a1feceec4","VersionId":"5a6d6c86169c491eb37ef2f9cda46a1b"},{"Name":"cp065268.exe","ProductId":"b5747db463a34c8c8ef853b408ae6b5c","VersionId":"c85b0f898c9b41b09538bba4a6aee7ce"},{"Name":"CP065974.zip","ProductId":"2fa1597649f243c092f040a8ecf90232","VersionId":"adc681f32ce94142a2a2f1eeaadc5385"},{"Name":"firmware-hdd-d39e7a7e75-HPG1-14.1.x86_64.rpm","ProductId":"c20869f6e72044ccb4d2b142b029a1ef","VersionId":"87bec7f582d5485e980870c6d97afc61"},{"Name":"HPE_UBM2_1.20_F.fwpkg","ProductId":"3b175f364fc14c6da598ff868e4cfb48","VersionId":"03cdf815345f4efd94751eaefd47e77f"},{"Name":"cp065066.exe","ProductId":"3d1400a6e0204fb498134f7e6e3f374a","VersionId":"6720cc3709904c8c9c7bb235b4af2a15"},{"Name":"cp065049.exe","ProductId":"e0822b357e024225a58d203426c0d686","VersionId":"46fc7ca8a03140e2a6e022426dceea63"},{"Name":"firmware-system-a42-3.72_2025_05_16-1.1.x86_64.rpm","ProductId":"f201f1f45a1041f9819da1901ffe255f","VersionId":"f58c18a103e04fe48586983d360f9be0"},{"Name":"libbnxt_re-233.0.152.2-rhel9u5.x86_64.rpm","ProductId":"9a174e7fb7c74693abe3d57081da0d45","VersionId":"921f006f3fba44469e1877b96f57acd7"},{"Name":"cp066689.zip","ProductId":"5588a72e9c0d4878a499b54f0c18241c","VersionId":"afdcd5951ff34634b4d048e306657fc7"},{"Name":"firmware-hdd-b04257b77b-HPDA-6.1.x86_64.rpm","ProductId":"4cf79b782386458fa01aea2ca94f4962","VersionId":"60cdffea2a1e42c5b5a9a902f468d1a2"},{"Name":"CP066005.zip","ProductId":"4aaa1b96312a4790820f2c40ac3eb0e7","VersionId":"accf85e27715420fa50c2afc082f49f0"},{"Name":"cp067568.exe","ProductId":"1f3d9896fbab4dc5aed295b2183323a0","VersionId":"857bfcbe05ed4b8b89774abbd85ed3ba"},{"Name":"cp065299.exe","ProductId":"30c69f83193c4f679a84938a219df0d6","VersionId":"e5223c34437248748019570a92b16b6a"},{"Name":"firmware-nic-open-mellanox-eth-mft-1.0.12-1.1.x86_64.rpm","ProductId":"ec5ba4f75ae340e39f8e129f646a9647","VersionId":"8c2fa2acc66543d58749447fee9bde89"},{"Name":"cp065081.exe","ProductId":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","VersionId":"e0943263ab7846f38694cac97a9a9271"},{"Name":"cp065062.exe","ProductId":"2a95310f5de64c9fad6c33cfacf5d307","VersionId":"cca5817a12074cc8b56484136dbcbcdf"},{"Name":"ice-kmp-default-1.16.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","ProductId":"29a000381a7c4ec8a72063a155821a0a","VersionId":"2aa0aed47e3f44398f0ecd43b0332c38"},{"Name":"ice-kmp-default-1.16.4_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","ProductId":"29a000381a7c4ec8a72063a155821a0a","VersionId":"2aa0aed47e3f44398f0ecd43b0332c38"},{"Name":"cp065604.exe","ProductId":"348f4fc22c0c4f64b2e050cebccb4347","VersionId":"e1c6772d6a5241e58f67c55dc47cb1b7"},{"Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-3.rhel10u0.x86_64.rpm","ProductId":"376766abc4f1493fa567046abeb8b7d6","VersionId":"bcdb5ae199284b4d8820f98aec46003d"},{"Name":"cp065082.exe","ProductId":"a25f1000baab4c289a20555c0f1143b1","VersionId":"4cefbaba980a4df7955ca3c9aaf0cb6b"},{"Name":"CP065979.zip","ProductId":"eacabd6c758c41759c1c132130d3f614","VersionId":"81a0178ad61c4266ba2c2e5a85a13a6a"},{"Name":"CP064990.zip","ProductId":"b80afd72e0994f04bb439cddf1f507eb","VersionId":"0fe16d5ce86d40a4ad67c0a96dd3d555"},{"Name":"cp066821.exe","ProductId":"18633ffffaeb4435bcda138419e66c7a","VersionId":"e4c258490e934f0a990926f19f6e7468"},{"Name":"cp066437.exe","ProductId":"e9a54d5b255e4c18936eebffaaff1ccf","VersionId":"9dc3b5318c8f478d9a5329038145f20d"},{"Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","ProductId":"aa9211e645514db69ecc4a92d0863429","VersionId":"fd4644ff6898456b8bf5d3a92e550bfa"},{"Name":"firmware-system-u48-3.60_2025_05_16-1.1.x86_64.rpm","ProductId":"2bd1c3f2d559498081c13ef5a6c74bb4","VersionId":"3096933d9b6f4387920bcbe738a69340"},{"Name":"cp066052.zip","ProductId":"43151427676f44dcaced68356cf6359c","VersionId":"91eedfc8544c413bbd1e5e7e2f1c20f9"},{"Name":"CP065986.zip","ProductId":"787f189347ac420fbe52f5e6292d569d","VersionId":"4adaf2607e844265be77d76abccb13f8"},{"Name":"cp067550.exe","ProductId":"25bee0f636714c0e8bface2301234fec","VersionId":"7afb11bacfba46a0be5e1c9e206d542d"},{"Name":"U56_2.42_06_13_2025.fwpkg","ProductId":"b0391b3a14de43ee99f90e7fe9de4040","VersionId":"6f57949889bd480c8347287baaca7fde"},{"Name":"cp066845.exe","ProductId":"009bd5d739814a67a018565d835c45f1","VersionId":"d307b6f4d26c47f5a1786eaf1a9993c5"},{"Name":"kmod-hp-ixgbevf-4.21.25-1.rhel9u4.x86_64.rpm","ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","VersionId":"d0be4ccbc1614f84bed735fd74805cac"},{"Name":"kmod-hp-ixgbevf-4.21.25-1.rhel9u5.x86_64.rpm","ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","VersionId":"d0be4ccbc1614f84bed735fd74805cac"},{"Name":"CP066008.zip","ProductId":"386eb9df6414454ca63bfe17b21ac760","VersionId":"14ca93ffa5f94a888d3e2e649aaea7a8"},{"Name":"cp064926.exe","ProductId":"188764648e874fd98523f669c6e5a042","VersionId":"99d02b411ae743f99d65ff8c8748b77e"},{"Name":"firmware-nic-mellanox-ethernet-only-1.0.22-1.1.x86_64.rpm","ProductId":"5c045315a07d45779f552f6cb831a2b4","VersionId":"778c7f56c3dc40119dde23bac6fbb2d1"},{"Name":"cp061748.exe","ProductId":"b88ebb63a68747808884160b11c000eb","VersionId":"1c14a167e97d417dbd3e1c7fb06d59c6"},{"Name":"cp065024.exe","ProductId":"b61013381e514e74835819b0f29c6165","VersionId":"54281078d04c4217bc3869e91e56b177"},{"Name":"MRStorageAdministrator-008.012.022.000-00.x86_64.rpm","ProductId":"8f24173ef2e740d2b110bb710e861366","VersionId":"fb060b0622484975bcabed0966c87fcf"},{"Name":"cp067164.exe","ProductId":"64242f6035c24947925dbb84f5af8b24","VersionId":"4521549d43354a3888b36ae8351ea42d"},{"Name":"cp065613.exe","ProductId":"effc199f67764de3b570f964be1aa0ce","VersionId":"2819e579c07f4408b797be9636f2f8bd"},{"Name":"cp067155.exe","ProductId":"3702e2a6624243b4a85fa9ca1f4c0ce2","VersionId":"391c05f3f59643309154acfc1b9e0bbb"},{"Name":"firmware-ml30gen10plus_me-06.00.03.700-2.1.x86_64.rpm","ProductId":"3eab1bf1c35b40e5b35b9f8cbcf441cd","VersionId":"308311eb37984a578428d34af1bacd35"},{"Name":"CP066510.zip","ProductId":"d0558c4ca40d4c1889688fd366d72022","VersionId":"4d4eeb5fca8642ac80b8d8ba61ff0ffb"},{"Name":"kmod-elx-lpfc-14.4.473.24-1.rhel9u6.x86_64.rpm","ProductId":"02e2779ea258441c8ba6426a8772f536","VersionId":"a4fac5794f124f64af63cf7178d65daa"}],"Description":[{"Lang":"en","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."},{"Lang":"ja","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."},{"Lang":"cn","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus (SPP) is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. This solution uses Smart Update Manager (SUM) as the deployment tool and is tested on all HPE ProLiant Gen10/10 Plus servers as defined in the Service Pack for ProLiant Server Support Guide located on the SPP TechLibrary page."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"DocumentationNotes":[{"Lang":"en","Value":"<p>Gen10 and 10 Plus SPP 2025.07.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.05.00.00 and includes support for SUSE Linux Enterprise Server 15 SP7.</p>"},{"Lang":"ja","Value":"<p>Gen10 and 10 Plus SPP 2025.07.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.05.00.00 and includes support for SUSE Linux Enterprise Server 15 SP7.</p>"},{"Lang":"cn","Value":"<p>Gen10 and 10 Plus SPP 2025.07.00.00 release supersedes Gen10 and 10 Plus&nbsp;SPP&nbsp;2025.05.00.00 and includes support for SUSE Linux Enterprise Server 15 SP7.</p>"}],"Id":{"Product":"5d74fe753828448f9472abbeb67af11d","Version":"89d66d9c56b3455482b7a2e8f7d3cfac"},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://www.hpe.com/support/SPPGen10-RN-en\">Gen10 and 10 Plus SPP Release Notes</a></p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://www.hpe.com/support/SPPGen10-RN-en\">Gen10 and 10 Plus SPP Release Notes</a></p>"},{"Lang":"cn","Value":"<p style=\"margin-left:0in; margin-right:0in\">There are two methods for using the&nbsp;Service pack for HPE ProLiant Gen10 and 10 Plus to update your ProLiant servers: Online mode and Offline mode.</p><p style=\"margin-left:0in; margin-right:0in\">Online mode - Runs on a Windows or Linux hosted operating system</p><ul><li>Interactive mode - Follow the onscreen steps to update firmware components<br />To initiate deployment in interactive mode, run the launch_sum.bat (windows) or launch_sum.sh (Linux) script which is found in the root of the .ISO image</li></ul><p style=\"margin-left:0in; margin-right:0in\">Offline mode - Server is booted to the .ISO image</p><ul><li>Automatic mode - Firmware components will be updated without interaction<br />Automatic mode will by default run firmware update without any user interaction after sitting 10 seconds at the menu screen&nbsp;when&nbsp;an&nbsp;SPP .iso image is used to boot the server.</li><li>Interactive mode - Follow the onscreen steps to update firmware components</li></ul><p style=\"margin-left:0in; margin-right:0in\"><strong>Click here for the</strong> <a href=\"https://www.hpe.com/support/SPPGen10-RN-en\">Gen10 and 10 Plus SPP Release Notes</a></p>"}],"LangList":[{"Lang":"en","Value":"English (US),Japanese,Chinese (Simplified)"},{"Lang":"ja","Value":"英語（US）,日本語,中国語（簡体）"},{"Lang":"cn","Value":"英语（美国）,日语,简体中文"}],"Name":[{"Lang":"en","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"},{"Lang":"ja","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"},{"Lang":"cn","Value":"Service pack for HPE ProLiant Gen10 and 10 Plus"}],"PrerequisiteNotes":[],"Prerequisites":{"SupportedOperatingSystems":[{"Id":"2","Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"10","Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Id":"6","Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"8","Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"1","Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Id":"4","Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Id":"3","Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"5","Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Id":"7","Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Id":"9","Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}]},"ProductSupportedOperatingSystems":[{"Family":"U34","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3"]},{"Family":"U30","SupportedOperatingSystemIDs":["2","8","10","6","1","4","5","3","9","7"]},{"Family":"U32","SupportedOperatingSystemIDs":["2","6","8","10","1","4","5","3","9","7"]},{"Family":"U37","SupportedOperatingSystemIDs":["2","1","10","6"]},{"Family":"SPP","SupportedOperatingSystemIDs":["10","6","8","1","4","5","3","9","2"]},{"Family":"A40","SupportedOperatingSystemIDs":["8","1","3","9","2","10","6","4","5","7"]},{"Family":"U41","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9"]},{"Family":"U33","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9"]},{"Family":"U40","SupportedOperatingSystemIDs":["2","8","10","6","1","4","5","3","9"]},{"Family":"U38","SupportedOperatingSystemIDs":["2","10","6","1","9"]},{"Family":"U45","SupportedOperatingSystemIDs":["2","10","6","1","9"]},{"Family":"A41","SupportedOperatingSystemIDs":["2","10","8","1","3","9","6","4","5","7"]},{"Family":"U43","SupportedOperatingSystemIDs":["2","10","6","1","4","5"]},{"Family":"U44","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9"]},{"Family":"U31","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3"]},{"Family":"A42","SupportedOperatingSystemIDs":["10","2","6","8","4","5","3","9","7","1"]},{"Family":"A43","SupportedOperatingSystemIDs":["2","10","6","8","4","5","3","9","7","1"]},{"Family":"U48","SupportedOperatingSystemIDs":["2","6","8","3"]},{"Family":"A46","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9"]},{"Family":"A47","SupportedOperatingSystemIDs":["10","6","3","8","1","4","9"]},{"Family":"A48","SupportedOperatingSystemIDs":["10","6","3","8","1","4","9"]},{"Family":"U46","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9","7"]},{"Family":"U47","SupportedOperatingSystemIDs":["2","10","6","8","1","4","5","3","9"]},{"Family":"U56","SupportedOperatingSystemIDs":["1","4","5","9","7"]},{"Family":"U50","SupportedOperatingSystemIDs":["2","10","6","3","7"]},{"Family":"U61","SupportedOperatingSystemIDs":["10","6","8","4","5","3","9"]},{"Family":"U60","SupportedOperatingSystemIDs":["10","6","8","4","5","3","9"]},{"Family":"U39","SupportedOperatingSystemIDs":["2","8","1","9","6","3","7"]},{"Family":"U64","SupportedOperatingSystemIDs":["6","8","4","5","3"]}],"ReleaseDate":{"Day":"08","Hours":"00","Minutes":"00","Month":"08","Seconds":"00","Year":"2025"},"RevisionHistory":{"ReleaseNotes":[{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2025.07.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.2.0 and HPE Integrated Lights-Out (iLO) 5 version 3.14.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2025.07.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.2.0 and HPE Integrated Lights-Out (iLO) 5 version 3.14.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Service pack for HPE ProLiant Gen10 and 10 Plus&nbsp;2025.07.00.00 release contains components supporting HPE ProLiant and HPE Apollo Gen10 and Gen10 Plus server platforms and options.</p><p>This SPP release contains Smart Update Manager (SUM) 12.2.0 and HPE Integrated Lights-Out (iLO) 5 version 3.14.</p><p>&nbsp;</p><p>For a complete list of components included in the SPP, see the Contents Report (contents.html) packaged in the ISO or view the report on the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">SPP TechLibrary page</a> under the Quick Links tab.&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.07.00.00"},"SPPGeneration":[""],"SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"Version":{"Revision":"","TypeOfChange":"1","Value":"2025.07.00.00"}}],"Components":[{"ProductId":"1655bc494b334729864d929c38544849","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Online Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"cn","Value":"升级HPE ProLiant Gen9扩展卡上机柜固件的在线智能组件"},{"Lang":"ja","Value":"HPE ProLiant Gen9エキスパンダーのエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17517688","DateModified":"2025-03-07T05:59:42","FileList":["/CP064922_BUILD_20.data","/CP064922.vmexe","/CP064922.vmexe64","/CP064922.vmfile","/CP064922_VMw.zip","/CP064922.xml","/payload.json","/CP064922_VMw.zip/index.xml","/CP064922_VMw.zip/vendor-index.xml","/CP064922_VMw.zip/metadata.zip","/CP064922_VMw.zip/vib20/CP064922/HPE_bootbank_CP064922_5.15.20-8.0.0.20613240.vib","/CP064922_VMw.zip/metadata.zip/vendor-index.xml","/CP064922_VMw.zip/metadata.zip/vmware.xml","/CP064922_VMw.zip/metadata.zip/vibs/CP064922--7112293561139101723.xml","/CP064922_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064922_5.15.20-8.0.0.20613240.xml"],"MD5Sum":"0ec86241b6c1ac70ae5c67b7c7eee662","Name":"CP064922.zip","Release":"2025-03-07T05:50:04","Revision":"C","SHA1Sum":"e2c6d693c1f940f6dc44d14ac062f7f5cb991f77","SHA256Sum":"829adadc87df0dd31251fca436d3cc4a1fc8cd3363659b20fc497dd80d3dc83b","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15","VibList":[{"Name":"CP064922","Version":"5.15.20-8.0.0.20613240"}]}],"Installation":{"Command":"CP064922.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp; &nbsp; &nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><br /><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-06T03:56:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support&nbsp;HPE ProLiant DL180 Gen10 Server</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>HPE ProLiant DL180 Gen10サーバーをサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support&nbsp;HPE ProLiant DL180 Gen10 Server</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1491d75394fa433089f3444461292a8c"}]},{"ProductId":"35452d3049b54455b15816bf1978a61f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JXUCC&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JXUCC&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22258630","DateModified":"2025-03-06T13:53:16","FileList":["/CP065932_BUILD_4.data","/CP065932.vmexe64","/CP065932.vmfile","/CP065932_VMw.zip","/CP065932.xml","/payload.json","/CP065932_VMw.zip/index.xml","/CP065932_VMw.zip/vendor-index.xml","/CP065932_VMw.zip/metadata.zip","/CP065932_VMw.zip/vib20/CP065932/HPE_bootbank_CP065932_HPD4.4-1OEM.800.1.0.20613240.vib","/CP065932_VMw.zip/metadata.zip/vendor-index.xml","/CP065932_VMw.zip/metadata.zip/vmware.xml","/CP065932_VMw.zip/metadata.zip/vibs/CP065932--4097815081717471274.xml","/CP065932_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065932_HPD4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"6adf8f070f79051b4430222ea26c9178","Name":"CP065932.zip","Release":"2025-03-06T13:52:32","Revision":"C","SHA1Sum":"32cc08b5c3715aa860d128c3043864f438c16ef0","SHA256Sum":"655cb4b38576e4c95c29e0fce45ac550992440b2cbf14d14406483a6b2384104","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065932","Version":"HPD4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:21:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"be0a1042d0204a86ac4cfc2eeaf6b666"}]},{"ProductId":"79949863b3a5452487d1035ae487743e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3231-3030-304759455350","Version":"HPG1"},{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3631-3030-304759455646","Version":"HPG1"},{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUANG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3032-3030-304759455648","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"ja","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"cn","Value":"This package provides firmware for the following drive models:  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Fix FW assert and other regular fixes.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3297036","DateModified":"2024-10-25T08:32:18","FileList":["payload.json","Seagate_Summit_SUMMITSUANG1.HPb","Seagate_Summit_SUMMITSUANG1.xml"],"MD5Sum":"a9ebeac65c8f1b3aacfbf52e6ddbc7a4","Name":"Seagate_Summit_SUMMITSUANG1.fwpkg","Release":"2024-10-25T08:30:02","Revision":"","SHA1Sum":"decedcb617ea27d08f042e549677cc478522cdbd","SHA256Sum":"2fc609cf4364c8564ad816c12a040bcc63f864c236a1f8ae590ea1570468bb2c","Size":"3MB","TargetGUIDs":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB12000GYESP","TargetGUID":"002340a5-424d-3231-3030-304759455350","Type":"sata"},{"Id":"MB16000GYEVF","TargetGUID":"002340a5-424d-3631-3030-304759455646","Type":"sata"},{"Id":"MB20000GYEVH","TargetGUID":"002340a5-424d-3032-3030-304759455648","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-25T06:14:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix FW assert and other regular fixes</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB12000GYESP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB16000GYEVF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB20000GYEVH","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"ea555e67d9a742e8bdd8e6455315b8b1"}]},{"ProductId":"1012a84c719148b1b9e7357e885d2199","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.393.20 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4289568","DateModified":"2025-03-13T13:04:17","FileList":["cp063484.xml","cpqsetup.exe","elxdrvr-fc-14.4.393.20-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"aec27660287ff0a677e9bb735f13beb4","Name":"cp063484.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"03de6fd11acb79688e0e87ba2885e6ad6b3daf99","SHA256Sum":"64774ea1493d265266e976622726d1e5df6af0fee9fb1aa42c8c6ef620a81b3c","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.393.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f259b17ac8c1433c8ed88cb61826714c"}]},{"ProductId":"134da74460bf4b5aa8511e630ba5a272","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"MicroserverGen10PlusSPS_05.01.05.005.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8408886","DateModified":"2025-01-17T07:38:14","FileList":["MicroserverGen10PlusSPS_05.01.05.005.signed.bin","MicroserverGen10PlusSPS_05.01.05.005.xml","payload.json"],"MD5Sum":"6dae26a90533925f5d736bb999f97ba8","Name":"MicroserverGen10PlusSPS_05.01.05.005.fwpkg","Release":"2025-01-17T07:35:46","Revision":"","SHA1Sum":"8db9c8776f3ec8c3e6a10594a512609998534f95","SHA256Sum":"fe597ca01369dcb7b340cf3e44df77ca96e279152af194df075ecfe87c8ac03d","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"0","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-01-18T07:08:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS)ファームウェアには、インテル製品アップデート(IPU)バージョンIPU.2023.3ガイダンスに沿ったアップデートが含まれています。<p><strong>ファームウェアの依存関係：</strong></p>なし        <p><strong>改善点/新しい機能：</strong></p><p>このバージョンは、IPU.2023.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし        ","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.04.913"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"0de1897dad504a8daf6c66dce90f256b"}]},{"ProductId":"c046b36cf8a0464e9240313acab20b06","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064980.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2444204","DateModified":"2025-01-18T20:43:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/CP064987.xml","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/cp064980.compsig","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/cp064980.zip","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.700-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064987.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064987.scexe"],"MD5Sum":"35b688b9621fa630e2df8826a8b877bc","Name":"firmware-microserverv2gen10plus_me-06.00.03.700-1.1.x86_64.rpm","Release":"2025-01-19T02:37:06","Revision":"","SHA1Sum":"130798126105137cd8efe897d5a3b602ff87cad1","SHA256Sum":"6488effc29166941b2ed79746d24853bc8e03a25a0ea039083518694d0b10132","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"0","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"ja","Value":"オンラインROMフラッシュ for Linux - Server Platform Services (SPS)ファームウェア for HPE ProLiant MicroServer Gen10 Plus v2"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-09T05:27:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services(SPS)ファームウェアには、Intel製品アップデート(IPU)バージョンIPU.2024.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPSは、システムROM 2.00（02/01/2024）以降と組み合わせる必要があります。<p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU.2024.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.604"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a4a10d05e61f48ca8ff25743406c9400"}]},{"ProductId":"02754226ca24415fbdc877dfe47af242","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"7.43"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"7.43"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"7.43"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"この x64 Smartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"9581005","DateModified":"2025-05-14T06:15:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/CP066639.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/HPE_luxor_7.43.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-7.43-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066639.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066639.scexe"],"MD5Sum":"b2fe9aef164e485bf7e1b6c4d2a075fb","Name":"firmware-smartarray-f7c07bdbbd-7.43-3.1.x86_64.rpm","Release":"2025-05-14T10:58:13","Revision":"C","SHA1Sum":"fae61ea631870f546b8cedcfb3fefbcec3a348c5","SHA256Sum":"3b96b3acdd648b4f5735a6da381368a8b98b2bde848f861146c54f5c6fdb0eef","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"7.43"}],"Installation":{"Command":"CP066639.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux(x64) - HPE SmartアレイP408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-02T01:57:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added SR308i-p G11/SR308i-o G11 on DL385/DL365 Gen11 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>DL385/DL365 Gen11のサポートにSR308i-p G11/SR308i-o G11を追加しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added SR308i-p G11/SR308i-o G11 on DL385/DL365 Gen11 support</p>","Fixes":"","Lang":"cn"}],"Version":"7.43"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.43"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0d9dbdc9e6fe4882bcfc994a76dade58"}]},{"ProductId":"321dd379dd1a436ab919b4529b332ece","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9221456","DateModified":"2025-05-21T01:22:15","FileList":["cp067177.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_3.60_05_16_2025.signed.flash"],"MD5Sum":"5e77d638ec42ba7d643c82270d0c376b","Name":"cp067177.exe","Release":"2025-05-21T01:20:41","Revision":"","SHA1Sum":"4ce50cdd7de50fc9f11dc3bd8a2e09b907e2ecac","SHA256Sum":"9df54e15ea72401595323aeffe444b06e3cee17098930a704f7e5850de50ae7b","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:40:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"45abad3f870b4e8697b8c10cf578084c"}]},{"ProductId":"5413adceb7d241de900274e399d9c777","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1077016","DateModified":"2025-04-01T05:44:20","FileList":["cp065377.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"97ed0b6ade0d93ed1ebce60a53a51e0e","Name":"cp065377.exe","Release":"2025-04-01T05:30:28","Revision":"B","SHA1Sum":"dc84028f1dea1776d3b87af0f4f13b720d496c3b","SHA256Sum":"53e78e011cdfec6eecdfdc35fbeb6b09bc672df4767a94f51c2561caaa58d34e","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel i350ドライバー for Windows Server 2019"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-21T07:55:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"14.0.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"cn"}],"Version":"14.0.5.0"}],"SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1092a48b7d4c48f1a608a0a2375d685e"}]},{"ProductId":"667c48761fdd439199126de11a3666a8","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064851.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2174163","DateModified":"2025-01-17T01:43:19","FileList":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/CP064853.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/cp064851.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/cp064851.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.005-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064853.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064853.scexe"],"MD5Sum":"41f7c0c059d409c23f3c435baca21a1b","Name":"firmware-microservergen10plussps-05.01.05.005-1.1.x86_64.rpm","Release":"2025-01-17T07:35:17","Revision":"","SHA1Sum":"a5a7d29f0cb401cc21c03e375ce30b542344cff0","SHA256Sum":"78b9e11107febbc2ce77927e8cc8bc521c4ea2bb9f8e7b955f61e3e0cc30db7f","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"0","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-01-18T07:08:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS)ファームウェアには、インテル製品アップデート(IPU)バージョンIPU.2023.3ガイダンスに沿ったアップデートが含まれています。<p><strong>ファームウェアの依存関係：</strong></p>なし        <p><strong>改善点/新しい機能：</strong></p><p>このバージョンは、IPU.2023.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし        ","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.04.913"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3a9ff46bfaac4f248e4cd838bb23ca2b"}]},{"ProductId":"83ce77cbc6db45d29c95de38716f222e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"4632400","DateModified":"2025-01-10T09:17:14","FileList":["cp065018.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssASFD4.rel"],"MD5Sum":"43c96a9d5fe771409e6cb1fd0e73000a","Name":"cp065018.exe","Release":"2025-01-10T09:13:41","Revision":"C","SHA1Sum":"ce6007bd2cf6540154cfd65990c6996a6611735f","SHA256Sum":"2793df62bd61f33f1fcf0acf84412bcf3165d9e4ee9769063e63af6714b8c8fc","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWUDB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T08:13:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0c2f0cf952984c77905fe68e1e83839d"}]},{"ProductId":"871bd1fc79994166a0695e4fb3b5fd65","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34003907","DateModified":"2025-05-21T07:41:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/A46_3.72_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/CP067156.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-3.72_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067156.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067156.scexe"],"MD5Sum":"846577d72383286d8972029586dfb3f5","Name":"firmware-system-a46-3.72_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"cd4f9aa98eba302b9b13286192453e75272b6069","SHA256Sum":"89c836ed932ab256e771e95e3252e961a035e8e48e1245d4e4cd8b89e4388858","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ec1ac8b803c84c7b8ac5b0b690b20f4a"}]},{"ProductId":"e6bb5c297d78402ab079f188773b5efc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2022用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2341784","DateModified":"2025-03-25T06:21:22","FileList":["cp066446.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"d731cf3b6f510feb52d64c0ac1ca73df","Name":"cp066446.exe","Release":"2025-03-25T06:07:02","Revision":"","SHA1Sum":"8f6879c96a0e208f0da7b3cb4091d00ec9016642","SHA256Sum":"1137841ced93cc4bb1a1fde7958e1a28a23e28462866252d6553fcd9340b5d3f","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5a5fa0a6e8b941bea246719f09e713b4"}]},{"ProductId":"6559625804344daab70667e2f1b0b044","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6075335","DateModified":"2025-05-14T07:59:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/CP066508.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066508.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066508.scexe"],"MD5Sum":"c58a2fbf39d958acdd4fc209971eb8fc","Name":"firmware-hdd-adb3ab8147-HPD8-7.1.x86_64.rpm","Release":"2025-05-14T12:48:04","Revision":"G","SHA1Sum":"3f13ddd39a9f3c777809828da20de40f9db46412","SHA256Sum":"8fd46ae0838578189d50a0c881c5eea816e20256560bef0d216494ba2788ffcb","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043262.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:24:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d53d764b08924595ad3cf172b8dc9bee"}]},{"ProductId":"d8c86b5c3ce7444dbebf7bd215bf1a32","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3772.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Gen9およびGen10サーバーシリーズHPE Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th>Single NVM Version</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2-port 361i Adapter</td><td>8000119A</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 361T Adapter</td><td>80001147</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td><td>800011A1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366T Adapter</td><td>800011F1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368i Adapter</td><td>80003AC5</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 369i Adapter</td><td>80003AC3</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568i Adapter</td><td>80003AC4</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 563i Adapter</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td><td>8000F231</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td><td>800016F1</td><td>1.3772.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td><td>8000F232</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562T Adapter</td><td>800016EF</td><td>1.3772.0</td><td>10.55.3</td></tr></tbody></table><p>The combo image v1.3772.0 includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p><p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p><p>&nbsp;</p><p><strong>This software package no longer contains Firmware for the below listed supported network adapters:</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2-port 363i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Communication Board&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560SFP+ Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561FLR-T Adapter&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561T Adapter</p><ul><li>The latest firmware version of above adapters, please refer to the link :&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes</a></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th>Single NVM Version</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2-port 361i Adapter</td><td>8000119A</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 361T Adapter</td><td>80001147</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td><td>800011A1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366T Adapter</td><td>800011F1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368i Adapter</td><td>80003AC5</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 369i Adapter</td><td>80003AC3</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568i Adapter</td><td>80003AC4</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 563i Adapter</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td><td>8000F231</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td><td>800016F1</td><td>1.3772.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td><td>8000F232</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562T Adapter</td><td>800016EF</td><td>1.3772.0</td><td>10.55.3</td></tr></tbody></table><p>The combo image v1.3772.0 includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p><p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p><p>&nbsp;</p><p><strong>This software package no longer contains Firmware for the below listed supported network adapters:</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2-port 363i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Communication Board&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560SFP+ Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561FLR-T Adapter&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561T Adapter</p><ul><li>The latest firmware version of above adapters, please refer to the link :&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes</a></li></ul>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th>Single NVM Version</th></tr></thead><tbody><tr><td>HPE Ethernet 1Gb 2-port 361i Adapter</td><td>8000119A</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 361T Adapter</td><td>80001147</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td><td>800011A1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 366T Adapter</td><td>800011F1</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368i Adapter</td><td>80003AC5</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 1Gb 4-port 369i Adapter</td><td>80003AC3</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568i Adapter</td><td>80003AC4</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td><td>80003AC2</td><td>1.3772.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 563i Adapter</td><td>800035C0</td><td>1.1375.0</td><td>N/A</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td><td>8000F231</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td><td>800016F1</td><td>1.3772.0</td><td>10.55.3</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td><td>8000F232</td><td>1.3772.0</td><td>11.1.7</td></tr><tr><td>HPE Ethernet 10Gb 2-port 562T Adapter</td><td>800016EF</td><td>1.3772.0</td><td>10.55.3</td></tr></tbody></table><p>The combo image v1.3772.0 includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p><p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p><p>&nbsp;</p><p><strong>This software package no longer contains Firmware for the below listed supported network adapters:</strong></p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 2-port 363i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 1Gb 4-port 366i Communication Board&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 560SFP+ Adapter&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561FLR-T Adapter&nbsp;&nbsp;&nbsp;&nbsp;</p><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port 561T Adapter</p><ul><li>The latest firmware version of above adapters, please refer to the link :&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\" rel=\"noopener noreferrer\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes\">https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_d7826493bb5a4aa69b4aa9a1d5&amp;tab=releaseNotes</a></li></ul>"}],"Files":[{"Bytes":"10312747","DateModified":"2025-04-07T02:20:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/CP065263.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/CP065263.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.33.1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP065263.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP065263.scexe"],"MD5Sum":"71f7ecfb28cde8eecc479ce6d03ba857","Name":"firmware-nic-intel-1.33.1-1.1.x86_64.rpm","Release":"2025-04-07T07:11:28","Revision":"","SHA1Sum":"1c53df2403ad517049cff8c3f99537fcfcf067a0","SHA256Sum":"1b5ae726a69aeffb36bba6f765c12ab12e5b2b0ededc1f471c67b452374c600e","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"1.33.1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":1800,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36","SWKey":"hp-ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccba99d79","SWKey":"kmod-hp-ixgbe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li><br /><li>&nbsp;</li></ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</a></li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"cn","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li><br /><li>&nbsp;</li></ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</a></li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"ja","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li><br /><li>&nbsp;</li></ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</a></li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"cn","Value":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor Linux x86_64（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:19:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、最新のドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.32.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.33.1"}],"SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:intel_nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa1eb759b39e4649b2cc5e07e16163f7"}]},{"ProductId":"f148b53c7b96447699a0d01706827644","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2302"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームでHPE Apollo A10 InfiniBand EDR（100Gb）2ポートアダプター（HPE部品番号843400-B21）、HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター（HPE部品番号872723-B21）、HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター（HPE部品番号872725-B21）のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.2302</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.4506</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.4506</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.2302</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.4506</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.4506</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.2302</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.4506</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.4506</td><td>HPE0000000008</td></tr></tbody></table>"}],"Files":[{"Bytes":"7871268","DateModified":"2025-04-22T05:41:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/CP066767.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw/fw-ConnectX4-rel-12_28_2302-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw/fw-ConnectX5-rel-16_35_4506-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw/fw-ConnectX5-rel-16_35_4506-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066767.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066767.scexe"],"MD5Sum":"1d0a0c7baec4e3d36cf5d0a41fcef466","Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.16-1.1.x86_64.rpm","Release":"2025-04-22T10:37:58","Revision":"","SHA1Sum":"757cba8c0ee215bb88807d7f8cd1d15fef909cb7","SHA256Sum":"9838bea2137bc582348d6e1958c3c5abdc9c9f72e80e9673f93d63d80c2a2465","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.16"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（Linux x86_64）for HPE Mellanox IB専用ConnectX4とConnectX5デバイス - Linux x86_64プラットフォーム"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00EF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000ef","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0257","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900257","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0255","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900255","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T06:14:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>irmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to 16.35.3006:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2ポートアダプター)<br /> </li></ul><p><strong>次のデバイス用のファームウェアが16.35.3006にアップデートされました。</strong></p><ul><li>872723-B21(HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター)</li><li>872725-B21(HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター)</li></ul><p> </p><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302では、新たな問題は修正されていません。</strong><br /> </p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>irmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to 16.35.3006:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.15"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.16"}],"SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a1b475e80749476d9a5096114dc25e70"}]},{"ProductId":"9d355b002f0f45528687c05a8ded7241","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4721464","DateModified":"2025-05-24T07:48:31","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"8b6dde734f31d45189742451513639ef","Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-1.rhel9u5.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"6daa4c421e634ceb95809e6552273f95d99b767e","SHA256Sum":"f6c24fd132ba4c4ab5b346c2c45e6db40c8f9ca661dc9bc67db08c1187a8302c","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.14.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u1.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />                   <br />                    # rpm -Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u1.x86_64.rpm<br /><br />4.  インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。  </p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                      # rpm -e kmod-qla2xxx-<version>.<OSupdate>.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u1.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 update 5 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 update 5 Serverファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプター"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 update 5 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e55e1a44fa88467cb5b8f94eaf46d614"}]},{"ProductId":"29b23e8f7b0d4dbf97ddc41ea0425103","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"WDC_ParisD_WparisdASFD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5655","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB020000JXMVU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB020000JXMVU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB020000JXMVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>An error was found in the queue full handling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset.</p></li><li><p>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented.</p></li><li><p>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョン：<br />      </strong>HPD1<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>キューのフル処理プロセスでエラーが見つかりました。その結果、FUAビットが適切に設定されず、ドライブの自発的なリセットを発生させる可能性があります。</p></li><li><p>キューのフル処理プロセスの間にFUAビットの処理を解決するFWの修正が実装されました。</p></li><li><p>FWは、キューのフル処理状況でドライブがリセットされる問題を解決することが確認されました。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>An error was found in the queue full handling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset.</p></li><li><p>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented.</p></li><li><p>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6539691","DateModified":"2025-02-19T17:43:22","FileList":["payload.json","WDC_ParisD_WparisdASFD1.HPb","WDC_ParisD_WparisdASFD1.xml"],"MD5Sum":"85823c795fa7e708242381d4ee4c7644","Name":"WDC_ParisD_WparisdASFD1.fwpkg","Release":"2025-02-19T17:41:28","Revision":"B","SHA1Sum":"6d125c64f6010da733f3f0c516e9cbac9d7548f0","SHA256Sum":"1d06562bfb78ad03ea253724415b4cc9d536be3359e87fbf66ed567151f2c4ab","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5655"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB020000JXMVU"},{"Lang":"ja","Value":"ドライブ用ユニバーサルファームウェアパッケージ - MB020000JXMVU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB020000JXMVU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB020000JXMVU","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5655","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T20:33:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>An error was found in the queue fullhandling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset</li><li>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented</li><li>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>キューのフル処理プロセスでエラーが見つかりました。その結果、FUAビットが適切に設定されず、ドライブの自発的なリセットを発生させる可能性があります。</li><li>キューのフル処理プロセスの間にFUAビットの処理を解決するFWの修正が実装されました。</li><li>FWは、キューのフル処理状況でドライブがリセットされる問題を解決することが確認されました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>An error was found in the queue fullhandling process that results in the FUA bit not getting properly set, which could lead to the drive self-initiated reset</li><li>The FW fix is to resolve the handling of FUA bit during the queue full handling process has been implemented</li><li>The FW was confirmed to resolve the issue of drives resetting under queue full handling situations.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"MB020000JXMVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"12e10145ad2c40a5aeb104112fcffe11"}]},{"ProductId":"39cff1d9c55641a8a5495e9c755fc456","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30505a575348","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-30505a57534b","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30505a575346","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-30505a584641","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO001600PZWSH、MO003200PZWSK、MO000800PZWSF、およびMO006400PZXFA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; It has fix code for V6 read disturb and other issues.<br />&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; It has fix code for V6 read disturb and other issues.<br />&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; It has fix code for V6 read disturb and other issues.<br />&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1980311","DateModified":"2025-02-19T16:10:22","FileList":["payload.json","Samsung_PM165X_GPM1655SAMD3.HPb","Samsung_PM165X_GPM1655SAMD3.xml"],"MD5Sum":"f2fe9294a08183fbe9a65bdd8aeedcf0","Name":"Samsung_PM165X_GPM1655SAMD3.fwpkg","Release":"2025-02-19T16:07:26","Revision":"B","SHA1Sum":"ac7fa2de47c718537c34c98ced5f4fa50eb82793","SHA256Sum":"46308d138404bea634f6f18b970c01d977f8e7939feb6d9333bec0fd6c9eb4eb","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3630-3430-30505a584641"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO001600PZWSH、MO003200PZWSK、MO000800PZWSF、およびMO006400PZXFA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600PZWSH","TargetGUID":"4d2340a5-304f-3130-3630-30505a575348","Type":"sas"},{"Id":"MO003200PZWSK","TargetGUID":"4d2340a5-304f-3330-3230-30505a57534b","Type":"sas"},{"Id":"MO000800PZWSF","TargetGUID":"4d2340a5-304f-3030-3830-30505a575346","Type":"sas"},{"Id":"MO006400PZXFA","TargetGUID":"4d2340a5-304f-3630-3430-30505a584641","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T15:02:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>It has fix code for V6 read disturb and other issues</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>It has fix code for V6 read disturb and other issues</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>It has fix code for V6 read disturb and other issues</p>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MO000800PZWSF","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001600PZWSH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PZWSK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PZXFA","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"6285d7963642460bad6ca9d9e6df55ca"}]},{"ProductId":"acccc3a79b934a56bc23c6e1a1b8169b","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575550","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575551","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575552","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575556","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575554","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575641","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30525a575555","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU "},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960RZWUP、VO000960RZWUQ、VO001920RZWUR、VO001920RZWUV、VO003840RZWUT、VO003840RZWVA、およびVO007680RZWUU "},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：<br />     </strong>HPD1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能:</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>この修正は、ホストが読み取りコマンドを発行したときに、ウェアレベリングプロセスの対象ブロックで回復不能なエラーが発生する可能性がある場合に行われます。</p></li></ul><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1158118","DateModified":"2025-02-19T16:21:18","FileList":["Kioxia_RM6_KARM6ALSHPD1.HPb","Kioxia_RM6_KARM6ALSHPD1.xml","payload.json"],"MD5Sum":"03fbf80e11569463731364bb3f790bb4","Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","Release":"2025-02-19T16:18:49","Revision":"B","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","Size":"1MB","TargetGUIDs":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960RZWUP、VO000960RZWUQ、VO001920RZWUR、VO001920RZWUV、VO003840RZWUT、VO003840RZWVA、およびVO007680RZWUU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO000960RZWUP","TargetGUID":"562340a5-304f-3030-3936-30525a575550","Type":"sas"},{"Id":"VO000960RZWUQ","TargetGUID":"562340a5-304f-3030-3936-30525a575551","Type":"sas"},{"Id":"VO001920RZWUR","TargetGUID":"562340a5-304f-3130-3932-30525a575552","Type":"sas"},{"Id":"VO001920RZWUV","TargetGUID":"562340a5-304f-3130-3932-30525a575556","Type":"sas"},{"Id":"VO003840RZWUT","TargetGUID":"562340a5-304f-3330-3834-30525a575554","Type":"sas"},{"Id":"VO003840RZWVA","TargetGUID":"562340a5-304f-3330-3834-30525a575641","Type":"sas"},{"Id":"VO007680RZWUU","TargetGUID":"562340a5-304f-3730-3638-30525a575555","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T15:36:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この修正は、ホストが読み取りコマンドを発行したときに、ウェアレベリングプロセスの対象ブロックで回復不能なエラーが発生する可能性がある場合に行われます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This fix is for unrecovered errors may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"VO007680RZWUU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWVA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWUT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUP","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"9f078413ab6e4fb6aeab7cecca2f01a6"}]},{"ProductId":"5ac3ee90b2184fa9828f960cd9d17840","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4335920","DateModified":"2025-01-10T11:52:19","FileList":["cp065043.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512ND8.rel"],"MD5Sum":"cda34524aec9dacc0f4b10a5e7a3523f","Name":"cp065043.exe","Release":"2025-01-10T11:47:27","Revision":"C","SHA1Sum":"5db6b4f638629797a2e9c9b74aa424bbf8410812","SHA256Sum":"578869f7f99d8a3bccefdfcf65ea06ea46910aaedd4985fb19c4816d8f36b3f9","Size":"4MB","TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T10:33:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"14aa588a040e4d64be87d0f217907679"}]},{"ProductId":"4ec88340a2ce4a0da239c4051a775bd6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3414496","DateModified":"2025-01-11T07:47:21","FileList":["4IYRHPG7.bin","cp065014.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"844b72deba76660757e069afd7998920","Name":"cp065014.exe","Release":"2025-01-11T07:43:10","Revision":"D","SHA1Sum":"690da31bf63d321cc67a5c4d5296143ab4b0dbeb","SHA256Sum":"df2bce2a1196cdfdac43d7fa6ad854743765b192acf6440db6f585b4eeca3b89","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T06:14:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5196b480169542dcaa0fd7b08d44cd20"}]},{"ProductId":"fbe68804b30c4fe28e13ea472cae5392","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19622651","DateModified":"2025-03-06T07:24:05","FileList":["/CP066006_BUILD_3.data","/CP066006.vmexe64","/CP066006.vmfile","/CP066006_VMw.zip","/CP066006.xml","/payload.json","/CP066006_VMw.zip/index.xml","/CP066006_VMw.zip/vendor-index.xml","/CP066006_VMw.zip/metadata.zip","/CP066006_VMw.zip/vib20/CP066006/HPE_bootbank_CP066006_HPG8.3-1OEM.800.1.0.20613240.vib","/CP066006_VMw.zip/metadata.zip/vendor-index.xml","/CP066006_VMw.zip/metadata.zip/vmware.xml","/CP066006_VMw.zip/metadata.zip/vibs/CP066006--4333994880115514426.xml","/CP066006_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066006_HPG8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"3dc277d00d0ca5b5da1946c2475ef809","Name":"CP066006.zip","Release":"2025-03-06T07:23:12","Revision":"C","SHA1Sum":"12800bb65c6c697cc923e50cbd221e33fe4d7e74","SHA256Sum":"824bfc9e684fb31c3394952a25269f26d9cfd659e8cc925180195e74f998e993","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8","VibList":[{"Name":"CP066006","Version":"HPG8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043253.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:05:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cfe31a29a2d64b97b00b6f7494c8b89a"}]},{"ProductId":"14652a1a392747089da4a4254064ac9d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33597882","DateModified":"2025-03-24T08:28:18","FileList":["A41_3.50_03_21_2025.signed.flash","A41_3.50_03_21_2025.xml","payload.json"],"MD5Sum":"12656c7fc6ece569384ada7ee16db810","Name":"A41_3.50_03_21_2025.fwpkg","Release":"2025-03-24T08:24:12","Revision":"","SHA1Sum":"1c862137079ed4c8d34d3fca13ea97a767ab760c","SHA256Sum":"89acfca86018c902c9f49fb6e8e872b7e3f882989e3c0e5e34d0c75fc621f1b5","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL325 Gen10（A41）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:23:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b36af805c7bd449c8aa7e3d1b2bd0c24"}]},{"ProductId":"00184010ed0a41829836f7c60269273f","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージは、Windowsオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet専用アダプター</strong></td><td><strong>ファームウェアバージョン</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"27495800","DateModified":"2025-01-16T05:57:54","FileList":["cp065134.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"2fe8916e0fa51433b9bf9e7117909d56","Name":"cp065134.exe","Release":"2025-01-16T05:56:23","Revision":"A","SHA1Sum":"e141c9235bb7e777f32e2fc42c16f29ffaebd24f","SHA256Sum":"f338d7af57670abf2a8a349c785909af1375a6b3673ae75d0ad7393c703fede3","Size":"26MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> インストールボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Windows x64) for HPE Mellanox Ethernetアダプター専用"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-16T04:40:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1900にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1900には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>ファームウェアバージョン16.35.4030には新機能の追加も変更もありません。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong></p><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4030で修正されました：</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.22(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><ul></ul><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.22(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><ul></ul><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong></p><p> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4030で修正されました：</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.22(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><ul></ul><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4b48446eae8448e1b570f15be03052a8"}]},{"ProductId":"b50552ebf09d445294b0b81e162643cf","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_44_1036-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.44.1036"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.44.1036</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.44.1036</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td><td>26.44.1036</td><td>MT_0000000575</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7123447","DateModified":"2025-04-11T07:08:16","FileList":["26_44_1036-MCX631102AS-ADA_Ax.pldm.signed","26_44_1036-MCX631102AS-ADA_Ax.pldm.xml","payload.json"],"MD5Sum":"356af91581f5e54101f1756c9a1b621a","Name":"26_44_1036-MCX631102AS-ADA_Ax.pldm.fwpkg","Release":"2025-04-11T07:06:23","Revision":"","SHA1Sum":"dffcb0d91218f1f142c7214bbba41d9658b0be59","SHA256Sum":"702ada9c33de4aa6cc500d8ad119690d15417da6053ca7a733e522bac47d4879","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"TypeOfChange":"1","Version":"26.44.1036"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3.  iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）- Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2ポートSFP28アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-17T08:52:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry.</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action r educes the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。<br /> </p><p><strong>バージョン26.43.1014には、以下の新機能と変更が含まれます。</strong></p><ul><li>VF移行中にCQドアベルが失われた場合に備えて回復手順を追加しました。</li><li>eSwitchマネージャーごとに選択されたすべての機能でエラーCQEイベントを示すオプションが追加されました。この表示は、エラーに関する関連情報 (シンドローム、function_id、タイムスタンプ、QP番号など) を含む新しいWQEとして定義されます。この機能は、新しい一般オブジェクトであるRDMA-Telemetryオブジェクトを使用して構成され、次の新しいキャップに依存します。</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_typesおよびHCA_CAP.rdma_telemetry。</p><ul><li>拡張カーネルロックダウン権限セット。新しいHCA機能ビットマスクフィールドtool_partial_capを使用して、ツール (権限TOOLS_RESORCES) によって次のサブ操作を呼び出すことができるようになりました。</li></ul><p style=\"margin-left:80px\">5つのサブ操作は次のとおりです。</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAPと他の機能</li><li>QUERY_VUIDと直接データ</li><li>QUERY_ROCE_ADDRESSと他のvport</li><li>SET_HCA_CAPと他の機能</li><li>POSTPONE_CONNECTED_QP_TIMEOUTと他のvport</li></ul><p style=\"margin-left:80px\">新しく追加された機能は次のとおりです。</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>ステアリングアクション (STC) の\"Jump To Flow\"テーブルパラメーターに'table_type_valid'および'table_type'フィールドが追加され、ユーザーがNIC_TXからFDB_TXにジャンプしてACLテーブルをバイパスできるようになりました。</li><li>さまざまなユースケースでNICドメインをバイパスすることでホップ削減を可能にしました。このようなアクションにより、大量のフローとデバイスを処理するためのホップ数が削減されます (PPSが向上します)。この新しい機能を有効にするために、テーブルのRX側にジャンプできるようにする新しいSTCアクションタイプ\"JUMP_TO_FDB_RX\"が追加されました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン26.43.1014で修正されました：</strong></p><ul><li>create_sqが無効なmboxを使用した場合、セットアップがクラッシュする。これで、無効なmboxが有効なDBに置き換えられました。</li><li>FACTORYのデフォルトのNV構成値のクエリを修正しました。ファームウェアは常に適用される「次」値を返しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry.</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action r educes the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"26.44.1036"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631102AS-ADAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"9c75e4e9d96a4d258bf94d565b7624fb"}]},{"ProductId":"b9b10cbec6a7489cae77c802c13728a1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD4"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB002000JYDNE and MB004000JYDPB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"6373524","DateModified":"2025-05-14T08:16:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/CP066556.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/SCIMARBPNSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066556.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066556.scexe"],"MD5Sum":"fff9373772bffcf16649bb7a65dd4c3d","Name":"firmware-hdd-d4be2aecbb-HPD4-2.1.x86_64.rpm","Release":"2025-05-14T13:04:06","Revision":"B","SHA1Sum":"2a05de729c565ef1ba4752ecda2a25b552bf130f","SHA256Sum":"17373eb587dc10e9c42768870cda890609243972c9d4a754fcfc04b2ab147051","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:39:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。</li><li>その他のログ機能とFW機能強化を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"df7bec0e2c644e30b5af706686855f56"}]},{"ProductId":"716670787e144aa5b4cf080bc78d2ef7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.40 (05/16/2025)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17078784","DateModified":"2025-05-20T07:24:49","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/CP067170.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/U64_2.40_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.40_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067170.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067170.scexe"],"MD5Sum":"c5b383af6871418e3d9bbcbbd295fc07","Name":"firmware-system-u64-2.40_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-20T12:15:02","Revision":"","SHA1Sum":"48321ef2a93d27f09b0ddffaa7bf8a0eb481f1ad","SHA256Sum":"f4573d0108ca599eae232fcecbbb3274649bb5af5cdc9ddf6a87d86372283767","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:34:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"236f85cbec8347b4a45c45f8a2751c16"}]},{"ProductId":"b929c06b33df46a182acd3e907e0dc53","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.473.14"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.473.14-1//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.473.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4584936","DateModified":"2025-02-14T08:22:14","FileList":["cp063479.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.473.14-1/firmware/","elxflashStandalone-windows-14.4.473.14-1/firmware/B14447314.grp","elxflashStandalone-windows-14.4.473.14-1/firmware/P14447314.grp","elxflashStandalone-windows-14.4.473.14-1/win/","elxflashStandalone-windows-14.4.473.14-1/win/elxflash.bat","elxflashStandalone-windows-14.4.473.14-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.473.14-1/win/x64/","elxflashStandalone-windows-14.4.473.14-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.473.14-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.473.14-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.473.14-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.473.14-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.473.14-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.473.14-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"MD5Sum":"b58ba68bbc5f3a4cdd2a10587d21b668","Name":"cp063479.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"4dd3332769ca4de448a3e0c472a630d1990a8ad6","SHA256Sum":"bccde957897a3eb197b255c4d7ed9c758713063607eb6ce1a1f0e03f6ce8a613","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.03.01"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<br />ダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019/2022/2025 x64"},{"Lang":"ja","Value":"HPEファームウェアフラッシュfor Emulexファイバーチャネルホストバスアダプター - Microsoft Windows Server 2016/2019/2022/2025 x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b8feb6cede2241f6b7c3bcc056b3fbb0"}]},{"ProductId":"5fcadb289d2a4581aa347222e1e2d7d1","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"233.1.135.7"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM5741x Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Broadcom NetXtreme-E BCM5741x Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM5741x Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-0572f282f8134709b2788a1a31</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"8534566","DateModified":"2025-04-09T03:11:14","FileList":["bcm233.1.135.7.pup.HPb","bcm233.1.135.7.pup.xml","payload.json"],"MD5Sum":"51342810abafbf3f6f2e819edd3f46c0","Name":"bcm233.1.135.7.pup.fwpkg","Release":"2025-04-09T03:09:22","Revision":"","SHA1Sum":"8e3413941392308e832fab624abd8c721bd0621d","SHA256Sum":"62d6a42a5fd5b1da64366dea4da77c20d0b0eb695e0c0f0ea8e21d52ba9b8adf","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"TypeOfChange":"1","Version":"233.1.135.7"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol style=\"list-style-type:decimal\"><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3. iLO GUIからのフラッシュ</p><ul style=\"list-style-type:square\"><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM5741x adapters"},{"Lang":"ja","Value":"Broadcomファームウェアパッケージfor BCM5741xアダプター"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM5741x adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanIdプロパティを削除します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断を向上させます。</li><li>この製品は、よりクリーンなインターフェイスを実現するために、HII MBAメニューを抑制するドライバーのアップデートを強化しています。</li></ul>","Fixes":"<ul><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、RDMA接続が確立されない問題を修正します。</li><li>この製品は、RoCEおよびTX/RXパスコアダンプのデコードが失敗する問題を修正します。</li><li>この製品は、ESXiでポート1がブロードキャストパケットを受信できない問題を修正します。</li><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、VLAN構成でPXEブートが機能しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"cn"}],"Version":"232.1.132.8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.1.135.7"}],"SWKeys":[{"Name":"BCM_NXE_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"2f1e35091c7f48c4bff95995f6bf2392"}]},{"ProductId":"230d4b31fe374aebb4d538e99b933aee","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssATFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB012000GWDFE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4449928","DateModified":"2025-01-11T12:51:15","FileList":["cp065094.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEAsssATFG5.rel"],"MD5Sum":"2263dde9c2b92378786ff6495c81fdc7","Name":"cp065094.exe","Release":"2025-01-11T12:46:54","Revision":"C","SHA1Sum":"772ed9ebe5cb7e93ec163a8475ff61d20fb1c286","SHA256Sum":"ebc49d0c605d938069283ee0239923dd13743c57b1a2895552047be2ebbee2a4","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000GWDFEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000GWDFE","TargetGUID":"4d2340a5-3042-3231-3030-304757444645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T12:16:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b2198a0a7ca14455989f643803f56333"}]},{"ProductId":"b4de54a776434c1baf230d968d3bb23f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4946064","DateModified":"2025-01-11T08:07:16","FileList":["cp065075.xml","cpqsetup.exe","HPG1_PM893.bin","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"ffd5fd757765458a87322cdf9980a0ce","Name":"cp065075.exe","Release":"2025-01-11T08:02:35","Revision":"C","SHA1Sum":"2989d1ac539e1c4e1b3db555e9e171aadd93dec0","SHA256Sum":"bb7373bbd599f9d64ef2d511a763d87e13b83c6ae44b9e7c5ab826556ab174a7","Size":"4MB","TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T05:49:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6287ed561ad74872a6bcc9f33fb128cd"}]},{"ProductId":"270849c2dba647ceb1f5f641d466f681","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 9.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"ja","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"cn","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"}],"Files":[{"Bytes":"453771","DateModified":"2025-04-09T02:04:17","FileList":["/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip","/cp066626.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_233.0.156.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_233.0.156.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vibs/bnxtroce--7165695560035088176.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vibs/bnxtnet--3231861591349352780.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4f41f97d52873f750bf129709816109d","Name":"cp066626.zip","Release":"2025-04-09T02:04:08","Revision":"","SHA1Sum":"6b91de261d1fe9432654b7bcc3ae66a1c09b998b","SHA256Sum":"657c4c09fe4f088fe6712928c9225b131d41f2c2edc4c304e7b68d39aadd71b1","Size":"443KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"bnxtroce","Version":"233.0.156.0-1OEM.800.1.0.20613240"},{"Name":"bnxtnet","Version":"233.0.156.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>最初のリリース</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:233.0.256.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:233.0.156.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:233.0.156.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e0ba16e260754ac28326d491aa4b619b"}]},{"ProductId":"f68792033b364ab4b274dc849cf93dea","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 8.0 and 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"10803678","DateModified":"2025-03-07T08:18:19","FileList":["/CP064261_BUILD_40.data","/CP064261.vmexe64","/CP064261.vmfile","/CP064261_VMw.zip","/CP064261.xml","/payload.json","/CP064261_VMw.zip/index.xml","/CP064261_VMw.zip/vendor-index.xml","/CP064261_VMw.zip/metadata.zip","/CP064261_VMw.zip/vib20/CP064261/HPE_bootbank_CP064261_4.20.0.40-1OEM.900.0.24580437.vib","/CP064261_VMw.zip/metadata.zip/vendor-index.xml","/CP064261_VMw.zip/metadata.zip/vmware.xml","/CP064261_VMw.zip/metadata.zip/vibs/CP064261--2746712027800506905.xml","/CP064261_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064261_4.20.0.40-1OEM.900.0.24580437.xml"],"MD5Sum":"c401d90383179cc3433da02d84be1053","Name":"CP064261.zip","Release":"2025-03-07T08:17:45","Revision":"","SHA1Sum":"4381c112510a3a8edf1ecd58a82dc59637ac4e29","SHA256Sum":"4a56ddfdd7dbeee9447bfa8df8ee588b5888a09b65d8119a70026e7fe804f04d","Size":"10MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"4.20.0","VibList":[{"Name":"CP064261","Version":"4.20.0.40-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul style=\"list-style-type:circle\"><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul style=\"list-style-type:circle\"><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul style=\"list-style-type:circle\"><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul style=\"list-style-type:square\"><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>手動によるインストール手順：</strong></p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul style=\"list-style-type:circle\"><li>ESXi 7.0ターゲットの場合：esxcli  software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li><li>ESXi 6.xターゲットの場合：esxcli software vib install -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul style=\"list-style-type:circle\"><li>次のコマンドを実行します：./Execute_Component -s</li></ul></li><li>Smartコンポーネントをクリーンアップします。<ul style=\"list-style-type:circle\"><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul style=\"list-style-type:square\"><li>ESXi 7.0ターゲットの場合：esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>ESXi 6.xターゲットの場合：esxcli software vib remove -n CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul style=\"list-style-type:circle\"><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul style=\"list-style-type:circle\"><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul style=\"list-style-type:circle\"><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul style=\"list-style-type:square\"><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"VMware 版 HPE QLogic FastLinQ 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-11-25T08:18:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"4.19.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"4.20.0"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d03f21f7e00b40b4996d662ba82ab674"}]},{"ProductId":"6b0653271f3e4e3a8e730542d61ffed8","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The lsi-mr3 controller driver component for VMware vSphere 8.0, for use with HPE Smart Update Manager."},{"Lang":"ja","Value":"HPE Smart Update Managerで使用するVMware vSphere 8.0用lsi-mr3コントローラードライバーコンポーネント"},{"Lang":"cn","Value":"The lsi-mr3 controller driver component for VMware vSphere 8.0, for use with HPE Smart Update Manager."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"238921","DateModified":"2025-06-10T10:58:00","FileList":["/BCM_bootbank_lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip","/cp064821.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/index.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/metadata.zip","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240.vib","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/metadata.zip/vibs/lsi-mr3-4424545440398427672.xml","/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240_24527057.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.732.03.00-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ac727542444651b7c5106ba2a53e2a88","Name":"cp064821.zip","Release":"2025-06-10T10:56:50","Revision":"C","SHA1Sum":"ff12c102bad24b14bb3517205257735b1b32e998","SHA256Sum":"daff86f7f260decdf6449aa5efa01d890afa384f73b237832f970f79057d31c6","Size":"233KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"lsi-mr3","Version":"7.732.03.00-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hpe/swpackages and ./hpesum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0"},{"Lang":"ja","Value":"HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusコントローラーおよびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバー(64ビット) for vSphere 8.0"},{"Lang":"cn","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいGen12 サーバーをサポートします。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.01.01"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 RC&nbsp;Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 RC ドロップ</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 RC&nbsp;Drop</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"Broadcom-lsi-mr3:7.732.03.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.732.03.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5b66cc941ba046d581762e8068dea3e4"}]},{"ProductId":"896ea0712e9c4853949ccb47860e6c63","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5870999","DateModified":"2025-05-15T10:15:36","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/CP066591.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066591.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066591.scexe"],"MD5Sum":"05db2f70bda5f12a7fc516fcdf1b2cc0","Name":"firmware-hdd-5dcf26fa42-HPD3-4.1.x86_64.rpm","Release":"2025-05-15T15:03:07","Revision":"D","SHA1Sum":"350b2c13729d046cd800f269aed64dfa93491ec0","SHA256Sum":"d8579d8aa5499aa964f27bfb466e5d98457236da0054acc6b011bb7c45c94e41","Size":"5MB","TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040329.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T17:26:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"33f2ed7dbb3848eeb9b4d5197c3a92a2"}]},{"ProductId":"d6464fc039cd4a77b22febd8762dca03","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"This component installs driverless INFs to identify devices in the processor and chipset."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"624136","DateModified":"2024-08-14T04:57:18","FileList":["cp062267.xml","cpqsetup.exe","installer.dll","pnp/","pnp/cannonlake-h.cat","pnp/CannonLake-HSystem.inf","pnp/CannonLake-HSystemThermal.inf","pnp/coffeelake.cat","pnp/CoffeelakeSystem.inf","pnp/null_heci.cat","pnp/NULL_HECISystem.inf"],"MD5Sum":"25258bf3374542eb6c0d3ed33e7847c2","Name":"cp062267.exe","Release":"2024-08-14T04:55:06","Revision":"C","SHA1Sum":"1e859db45b4b28d36056853d8a895672ac2e1e21","SHA256Sum":"ce74f1d8305d2d95e3731fa170f6a77ace1fae8e10fad53920e831490183b37d","Size":"609KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19928.8615"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeon E-22xxプロセッサーの識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-15T07:13:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.18807.8279"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li><li>Updated&nbsp;Supported Platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li><li>Updated&nbsp;Supported Platforms</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li><li>Updated&nbsp;Supported Platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19928.8615"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3d164c91b5b244768a9f00ad9713375e"}]},{"ProductId":"7af1785af4fd43e38986cbbadda39482","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"9856995","DateModified":"2025-05-14T05:54:40","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/CP066526.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/MPK7825Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066526.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066526.scexe"],"MD5Sum":"4fe07115c79ca7e2d140bfc24ea69ab4","Name":"firmware-hdd-951aefd63e-MPK7825Q-5.1.x86_64.rpm","Release":"2025-05-14T10:44:06","Revision":"E","SHA1Sum":"9bcc2ad8e637f702ebd228a84a8bfb6d5ad160d5","SHA256Sum":"3f2df28ae0add7aca319e6473eecf48490747937f8e5af883f5f9fb2b75bddc3","Size":"9MB","TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:20:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.<br />&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。<br /> </li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.<br />&nbsp;</li></ul>","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dee9d1e3ef444e36bfc435ccabecc929"}]},{"ProductId":"1aa231a863f54088aaed47c33f55bded","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"16674534","DateModified":"2024-12-10T09:19:24","FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"MD5Sum":"30774214a7c011ec26a4acf011d2576d","Name":"kmod-qlgc-fastlinq-8.74.6.0-1.rhel9u4.x86_64.rpm","Release":"2024-12-10T08:51:46","Revision":"","SHA1Sum":"e8f076cf08210bdaec4912e285de0afd5a26fa59","SHA256Sum":"41ae62fdf58013cc237e81853a05cb7bf890b5bc4248af2b253d7efa2d1a69c1","Size":"15MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.74.6.0-5"},{"Bytes":"16486564","DateModified":"2024-12-10T09:24:45","FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"MD5Sum":"16449ec098eb0e8ada70c9c76e5bbcce","Name":"kmod-qlgc-fastlinq-8.74.6.0-5.rhel9u5.x86_64.rpm","Release":"2024-12-10T08:51:46","Revision":"","SHA1Sum":"cd910b9de1bf74c782963f4fe17edd0c50c402ee","SHA256Sum":"48205744b60db90fb9c8907c424059454cc827c9537a0ed116942a93bdbc8a74","Size":"15MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.74.6.0-5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9 update 4.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Red Hat Enterprise Linux 9 Update 4をサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9 update 4.</p>","Fixes":"","Lang":"cn"}],"Version":"8.74.4.0-8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.74.6.0-5"}],"SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"0c4e6448b66841b796bbcf31aac56945"}]},{"ProductId":"6f1e3dc0362445eba42c38fd34e5d638","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18925796","DateModified":"2025-03-06T06:42:10","FileList":["/CP066004_BUILD_4.data","/CP066004.vmexe64","/CP066004.vmfile","/CP066004_VMw.zip","/CP066004.xml","/payload.json","/CP066004_VMw.zip/index.xml","/CP066004_VMw.zip/vendor-index.xml","/CP066004_VMw.zip/metadata.zip","/CP066004_VMw.zip/vib20/CP066004/HPE_bootbank_CP066004_HPDA.4-1OEM.800.1.0.20613240.vib","/CP066004_VMw.zip/metadata.zip/vendor-index.xml","/CP066004_VMw.zip/metadata.zip/vmware.xml","/CP066004_VMw.zip/metadata.zip/vibs/CP066004-3420236790855351228.xml","/CP066004_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066004_HPDA.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"77ff39c6dd222313622b84c1579c18e6","Name":"CP066004.zip","Release":"2025-03-06T06:41:20","Revision":"E","SHA1Sum":"c9b52dc775b0bff3f2dce31efe0f51218c03bbf6","SHA256Sum":"a3ae20ec5c54071af83ccd26cb573c668b69fa31f56903d1ea1e3fcccfb1cd13","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA","VibList":[{"Name":"CP066004","Version":"HPDA.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042542.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:02:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f38300f9f29d40558648ce3d9c0e2ab3"}]},{"ProductId":"74b3fe77108f45dc915915f121f04357","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"857951","DateModified":"2025-05-24T08:50:31","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"5667d505044c56d087ed1c2b08b45c9c","Name":"kmod-elx-lpfc-14.4.473.24-1.rhel10u0.x86_64.rpm","Release":"2025-05-24T08:46:04","Revision":"","SHA1Sum":"c2e9fa76e95ef9b519baa78923763c4c1cb251fe","SHA256Sum":"da12d81e1329aab244239be43cdf4883e7fd40080210468aed2a8085e6c824a1","Size":"837KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.473.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Server Update 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-20T04:11:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"87543008a4804bdfb1f7186879a9d47c"}]},{"ProductId":"aedcdb1596004cf4a73ef573a3625e08","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.473.14"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.473.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5729954","DateModified":"2025-03-07T05:46:38","FileList":["/CP063477_BUILD_12.data","/CP063477.vmexe","/CP063477.vmexe64","/CP063477.vmfile","/CP063477_VMw.zip","/CP063477.xml","/payload.json","/CP063477_VMw.zip/index.xml","/CP063477_VMw.zip/vendor-index.xml","/CP063477_VMw.zip/metadata.zip","/CP063477_VMw.zip/vib20/CP063477/HPE_bootbank_CP063477_2025.03.01.12-8.0.0.20613240.vib","/CP063477_VMw.zip/metadata.zip/vendor-index.xml","/CP063477_VMw.zip/metadata.zip/vmware.xml","/CP063477_VMw.zip/metadata.zip/vibs/CP063477-7622546070653568162.xml","/CP063477_VMw.zip/metadata.zip/bulletins/Smart-Component-CP063477_2025.03.01.12-8.0.0.20613240.xml"],"MD5Sum":"5df14af64a7573e27379bbd05005ff96","Name":"CP063477.zip","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"baee63c951dc37700da4cd003c5f58623fa1f841","SHA256Sum":"23bb67e63db02475c0938ab3e39a25454ca5b0e8f0c402522f0b2d6b5cbf1d59","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.03.01","VibList":[{"Name":"CP063477","Version":"2025.03.01.12-8.0.0.20613240"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください。<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  8.0"},{"Lang":"ja","Value":"HPE ファームウェアフラッシュ for Emulex ファイバーチャネルホストバスアダプターfor VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"784bd405fd74436a833b22827ab2b7fb"}]},{"ProductId":"b8bfd68496a643cdaece510776fb4ad2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントには、Mircosoft Windows Server 2022用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1099592","DateModified":"2025-04-07T02:03:13","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp066627.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"97b3a56b6a9923c8520f1dc8601ee2b3","Name":"cp066627.exe","Release":"2025-04-07T01:49:06","Revision":"","SHA1Sum":"34e58e0aeae783e13df1e6f6521357d137a46b82","SHA256Sum":"ad8f150d181ff4dd70e2b50f1b50c4fe1f893bcdcdd2b4b7c7e79b49708ab145","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"233.0.148.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41592","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"1760","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e41760","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D6","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41596","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41599","Type":"pci","Ven":"14e4"},{"Dev":"1808","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41598","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41599","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1751","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41751","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41599","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41598","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41599","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180800000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"},{"Dev":"1809","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180900000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、NXEファミリデバイスの一貫したPTPクロックのレポートを強化します。</li><li>この製品は、必要なPNP IDを追加することでデバイスの互換性を強化します。</li></ul>","Fixes":"<p>この製品は、未使用のrelease.txtファイルが削除されない問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"cn"}],"Version":"232.0.155.7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.148.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"768309fda01049dbb2abd796a34a80bc"}]},{"ProductId":"14db461db87a4c46b9be1a6560ae1f85","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 9.0"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 9.0"},{"Lang":"ja","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"}],"Files":[{"Bytes":"307825","DateModified":"2025-02-13T02:15:27","FileList":["/cp065386.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/vendor-index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/vib20/i40en/INT_bootbank_i40en_2.9.2.0-1OEM.800.1.0.20613240.vib","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vmware.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vibs/i40en-7395401369198326719.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/bulletins/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"3f2419f58af5096a32e0594a573d7680","Name":"cp065386.zip","Release":"2025-02-13T02:14:53","Revision":"","SHA1Sum":"80395b7e7a43f40d6feda361b41383ce194e01cc","SHA256Sum":"2fdf390f4eba0b39a4d72d6b40e4169edf384db97e236b03d6946639cd9e563a","Size":"300KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"i40en","Version":"2.9.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40en Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel i40en Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel i40en Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-22T03:09:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"Intel-i40en:2.9.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.9.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"02dcbb71ad884820b33ca4ab7e8f6522"}]},{"ProductId":"840d26617d5744de973393a116bf720d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3497504","DateModified":"2025-01-10T23:45:18","FileList":["4ICRHPK3.rel","cp064795.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"d23d162e1dc8e94f9618bd401ab84681","Name":"cp064795.exe","Release":"2025-01-10T23:40:06","Revision":"H","SHA1Sum":"b3b792467d6eacad64ce4025eaa5e1f1122b6b02","SHA256Sum":"3cc09aaaa587099995dce165e176cc3dac31ed87957b1521791a0be71258921f","Size":"3MB","TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-16T14:53:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"52b860adb81246158abb9ecde83b2875"}]},{"ProductId":"c91a34b258694c1696514c7b51041b33","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33593620","DateModified":"2025-05-21T13:34:16","FileList":["A48_3.72_05_16_2025.signed.flash","A48_3.72_05_16_2025.xml","payload.json"],"MD5Sum":"319ab0e1394bd56c507683f82233739e","Name":"A48_3.72_05_16_2025.fwpkg","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"283c5985384306edcb4bc8bdac85f9ab02e547b9","SHA256Sum":"8df104390bf3270e862907f55961ffb9ab610801bbdbb91d977ff566d8d94f58","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus(A48) サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a2933b8eee09410db17f38e2a5464268"}]},{"ProductId":"130da7feaa1d444b8b70a759892883b1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"Lang":"ja","Value":"このコンポーネントは、NVMeドライブをイジェクトする際の致命的なマスク不可割り込み (NMI) を修正するためにレジストリの変更をインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"619360","DateModified":"2025-01-14T07:21:19","FileList":["cp065111.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"MD5Sum":"11cd76192ca2dc086cd68d37010dc3d9","Name":"cp065111.exe","Release":"2025-01-14T07:19:15","Revision":"H","SHA1Sum":"d15dd618a2c4756170765064a64b94e29d69346d","SHA256Sum":"a37daef29ebefc68d9a91dcf5939d9b771180ef69a538bbb4d3356345d01f503","Size":"604KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"TypeOfChange":"0","Version":"1.1.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Microsoft Windows 64ビット用NVMe Drive Eject NMI Fix forインテルXeonプロセッサースケーラブルファミリー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedDevices":[{"Dev":"2020","SubDev":"00EA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-2020159000ea","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-14T07:09:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.1.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.1.0.0"}],"SWKeys":[{"Name":"nvmeejectfix5.dll","SWKeyExpectedPath":"%ProgramFiles%\\nvmefix"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fe3757c9f2ac476f854173dc90d7354d"}]},{"ProductId":"283d84a861d348648dca86da7b4218bd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1244160","DateModified":"2025-03-28T09:29:13","FileList":["cp065281.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"137da6a437b1fd99e65880b2f532df9b","Name":"cp065281.exe","Release":"2025-03-28T09:15:07","Revision":"B","SHA1Sum":"977e5be5269f87cbd8fd9c63e00b55c6e08d8d38","SHA256Sum":"95b702c0bd7ed4db7585668ecd1d850c4ba1840a8224c5cd529d1ea87eb20d42","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2022"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:04:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.165.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"714a3d8508994dbfa8ad3b7ccab48a4d"}]},{"ProductId":"fc2945bc3e5744fea9d120a012546560","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6533801","DateModified":"2025-05-15T10:00:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/CP066542.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066542.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066542.scexe"],"MD5Sum":"090469c628952fdcbbcd1ee8d91943e7","Name":"firmware-hdd-41cdb1c9da-HPG3-4.1.x86_64.rpm","Release":"2025-05-15T14:48:21","Revision":"D","SHA1Sum":"12b8027bc584da5ea6caff83946d195aeea91524","SHA256Sum":"d220eb957230ec3d5acac668a624bd6fe617bf63cd79a55f94e700154778f935","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041508.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:34:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1af648eb5fe8455fb56362345ec01922"}]},{"ProductId":"779f4f17fec64b6b9acf9ede668fc68a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"5113834","DateModified":"2025-05-15T11:00:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/CP066521.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/TA15SEn0HPD5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066521.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066521.scexe"],"MD5Sum":"3d55e5741d3fa8d1ed4e2cea150d0fef","Name":"firmware-hdd-24fe569b72-HPD5-8.1.x86_64.rpm","Release":"2025-05-15T15:49:05","Revision":"H","SHA1Sum":"97c73d3478f829829dd23f9e18b0730f042a1f08","SHA256Sum":"31c9565836d1be0975fe22a8e768527a3580f9b6f26e013be4514d1eda390f21","Size":"4MB","TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP041564.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP.<nnnnnn>scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T06:47:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1c3e90b4416b41469a31281a6de77def"}]},{"ProductId":"ec5fd859b967489ab6f67ad677712984","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19829256","DateModified":"2025-03-06T08:30:14","FileList":["/CP066003_BUILD_7.data","/CP066003.vmexe64","/CP066003.vmfile","/CP066003_VMw.zip","/CP066003.xml","/payload.json","/CP066003_VMw.zip/index.xml","/CP066003_VMw.zip/vendor-index.xml","/CP066003_VMw.zip/metadata.zip","/CP066003_VMw.zip/vib20/CP066003/HPE_bootbank_CP066003_HPDD.7-1OEM.800.1.0.20613240.vib","/CP066003_VMw.zip/metadata.zip/vendor-index.xml","/CP066003_VMw.zip/metadata.zip/vmware.xml","/CP066003_VMw.zip/metadata.zip/vibs/CP066003--5506596142151457280.xml","/CP066003_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066003_HPDD.7-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f1e9e3165fae580b0ae33072cb747060","Name":"CP066003.zip","Release":"2025-03-06T08:29:22","Revision":"B","SHA1Sum":"5320c777fabba6b3f85d1e6187ef6fd17a19453d","SHA256Sum":"ab74742487e0244f1d3a09058e6df3f4caaf256e6944ac83985d4de043950f6f","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD","VibList":[{"Name":"CP066003","Version":"HPDD.7-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040536.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:01:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f33261fbafa04ae9884d1df548b7524d"}]},{"ProductId":"73ec3bde4c824e4abd7a12e09eb4bcb4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6231076","DateModified":"2025-05-14T06:45:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/CP066548.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/SSKYBT512ND8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066548.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066548.scexe"],"MD5Sum":"f998b8bd3f2092a05efc8bd44cbdf7e5","Name":"firmware-hdd-bdfb8e99d9-HPD8-5.1.x86_64.rpm","Release":"2025-05-14T11:34:06","Revision":"E","SHA1Sum":"cdb48ce2d5491bfe3e09f9fb4f0e2d6a345b3143","SHA256Sum":"294bd7bb62c8e4d7161ef070ca7c1e08d717ffc5ef7c293867748866efa79d00","Size":"5MB","TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041693.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T14:14:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6cc11960dd3d4f65923b64b2b8c41449"}]},{"ProductId":"9955e8989d3a49ccb377a1c01a7b8a6c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the Power Coordination algorithm which ensures the drive will properly negotiate power with SPL-2 and newer compliant controllers.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6395989","DateModified":"2025-05-14T07:13:44","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/CP066550.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/SSKYBT512EDA.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDA-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066550.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066550.scexe"],"MD5Sum":"5a4a667c84cde29510e039e5063bcb5c","Name":"firmware-hdd-b1c9eaf74c-HPDA-6.1.x86_64.rpm","Release":"2025-05-14T11:50:05","Revision":"F","SHA1Sum":"9ee22786f565daa9d1bc67dfd97d47f655b10cf2","SHA256Sum":"1200ecbffc35d5e04258655e8007e63352e047648d83442d78a191f303527618","Size":"6MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T14:41:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"54a60164ec114fcab8cf2a1356a8547f"}]},{"ProductId":"fdd1b58860474c42b7f3b1b7524af387","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixed an incompatibility issue in MCTP over PCIe VDM function</li><li>Updated WCTEMP value for thermal throttling threshold</li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00130699en_us</a></li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"7372717","DateModified":"2025-05-14T05:33:00","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/CP066498.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066498.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066498.scexe"],"MD5Sum":"165c2dd7591081b18230a2cd6ad5c2f4","Name":"firmware-hdd-035a863453-HPK5-10.1.x86_64.rpm","Release":"2025-05-14T10:21:38","Revision":"J","SHA1Sum":"62cec260a84571db33601477cc6e1421a0b20a72","SHA256Sum":"0a641eb928a639038fecd51731a06b2630ad6fb41f168e559eb39436be4b435a","Size":"7MB","TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"CP042953.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T15:04:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"908ab9fdc0bb45d3976c6be0b77505af"}]},{"ProductId":"e3abad55c63d42f3bfc00d8212a8e9d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5127134","DateModified":"2025-05-15T10:45:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/CP066518.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/TA14SXe0HPD8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066518.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066518.scexe"],"MD5Sum":"e751f7bfc91e9912865d9a35ebae833d","Name":"firmware-hdd-c7df7ceedb-HPD8-6.1.x86_64.rpm","Release":"2025-05-15T15:34:04","Revision":"F","SHA1Sum":"e5ef5d06c81ff4ada691ae5ba87b0cf4c6227fb5","SHA256Sum":"feaa64b8b5ccb34db132b7036768a6767bb61a351d2f13ea9d30a93b0e4e80a2","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP.<nnnnnn>scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"},{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T04:47:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4548f3f1bc454264b79206bc57b9ad90"}]},{"ProductId":"95e1a7b8a2664cd8b8d67128eff9bb87","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"590624","DateModified":"2024-03-19T01:16:14","FileList":["cp060559.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"c9a2835a6b374d89b3681f27bc2724a0","Name":"cp060559.exe","Release":"2024-03-19T01:14:26","Revision":"E","SHA1Sum":"a3743479c57782fd162050fed921151f8d6ca251","SHA256Sum":"1cd9343807f4628ed4fbb912277f727e6ab28081918a7f6b2255982f530ef393","Size":"576KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and 2019"},{"Lang":"ja","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-04-18T16:18:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a6b8df86acec417b902821bab4453fec"}]},{"ProductId":"1e10e20d274448bb9d2d1625880b482d","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2022 and Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4107240","DateModified":"2025-02-13T07:02:22","FileList":["cp064335.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.19.27.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"ae2e140e5d85fd4876bf934fd7035841","Name":"cp064335.exe","Release":"2025-02-13T06:54:01","Revision":"","SHA1Sum":"1c7f900bd1f135553d6dc5696e1c987065cdc302","SHA256Sum":"7d5ec981ffb445470aed524d374d6da463756d77d54c25149610440b51829088","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"5.3.9.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","SWKey":"evbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.13.165.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T03:50:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"cn"}],"Version":"5.3.8.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.3.9.0"}],"SWKeys":[{"Name":"QlNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7c389a5d51614522ab0addc3b614ba45"}]},{"ProductId":"1bc921f76f2d48759522424a4aff4914","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11576528","DateModified":"2025-04-18T14:16:11","FileList":["cp066844.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_3.50_04_17_2025.signed.flash"],"MD5Sum":"208d40afc57b7b27c24f0a7d6156fe1d","Name":"cp066844.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"619c7e1a008d4e4b02cb8c50ec361470f79e098a","SHA256Sum":"30d9bf0502042d356920b62ff0fd3f51f0a1973dfd813075cd8b9d2684f844dc","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4efc8cfd981840519a9b624fb2669c90"}]},{"ProductId":"87793aff72a54849a327ce026784372d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1078288","DateModified":"2025-03-28T07:50:18","FileList":["cp065357.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"9e199121438db27f329e9c434a8a0c8d","Name":"cp065357.exe","Release":"2025-03-28T07:36:06","Revision":"B","SHA1Sum":"e9535ec7bfbd4b7d274592b97ecc96b519e65189","SHA256Sum":"56a666eea8fe349b067e0779a5fcb83ba63b17f3504fc4da3cb0bd49ae95dcdb","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T08:18:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"14.0.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 3.</p>","Lang":"cn"}],"Version":"14.0.5.0"}],"SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6a450f31c1334bba95d149e834716540"}]},{"ProductId":"8e4da865e5b44ea38e4b650ce9a93715","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4310960","DateModified":"2025-01-11T10:05:15","FileList":["cp065080.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNESD8.rel","setup.dll"],"MD5Sum":"9cd34934ed9530d20e6e10548d55f526","Name":"cp065080.exe","Release":"2025-01-11T10:01:24","Revision":"D","SHA1Sum":"bb2572f79b780300d722c6578136ee6f0839937a","SHA256Sum":"a6ffb8f4533d4cb4e42bc12ce61089171e047538241ac176f3298a80bf6ebf36","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:21:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6a72e30d8bff4e86ad74c09d80c29f62"}]},{"ProductId":"d6810024a18142b0a4b8ec4db68a4e55","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3681620","DateModified":"2025-07-27T12:14:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/CP067519.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067519.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067519.scexe"],"MD5Sum":"9884c4a24af2cd12efda125c6972e9dd","Name":"firmware-d3000-5.04-14.1.x86_64.rpm","Release":"2025-07-27T17:01:18","Revision":"N","SHA1Sum":"b0dbc77d2f1c4303782c31a8e0ce9717c264ee63","SHA256Sum":"b42454e068975d16ddbb107a3d0233700cc3f036e13e3da513934c8ff161b898","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"Installation":{"Command":"setup","CommandParams":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"Linux (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T06:20:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加 </p></li><li><p>Rhel 8.2のサポートを追加 </p></li><li><p>SLES15 SP2のサポートを追加しました。</p></li></ul>","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加</p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v271806/20-D3000-Gen10RN504N_ED14.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4558c10b3a5847748362b2692a0761dc"}]},{"ProductId":"33179a0f0a644a26bd07818fb3f2db4e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6788941","DateModified":"2025-05-14T06:38:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/CP066531.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/HPG1_PM893.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066531.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066531.scexe"],"MD5Sum":"d95c289b1a2cb64dbd4de8f4748afb41","Name":"firmware-hdd-abd133f0de-HPG1-5.1.x86_64.rpm","Release":"2025-05-14T10:58:15","Revision":"E","SHA1Sum":"9f4cbe3180379cbc3d7331f2ff19f8afd9bdd267","SHA256Sum":"7333ae76a758e4eadbc1f033c5ad2c91f9ce0fbd64a2aaec96a4af0d6ff6bf25","Size":"6MB","TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:54:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8d014470a00646798e7ef5816fbbb79d"}]},{"ProductId":"a2bc84f793fd4972b6196baf3df85eb6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20843316","DateModified":"2025-03-07T06:43:56","FileList":["/CP065992_BUILD_5.data","/CP065992.vmexe64","/CP065992.vmfile","/CP065992_VMw.zip","/CP065992.xml","/payload.json","/CP065992_VMw.zip/index.xml","/CP065992_VMw.zip/vendor-index.xml","/CP065992_VMw.zip/metadata.zip","/CP065992_VMw.zip/vib20/CP065992/HPE_bootbank_CP065992_HPD4.5-1OEM.800.1.0.20613240.vib","/CP065992_VMw.zip/metadata.zip/vendor-index.xml","/CP065992_VMw.zip/metadata.zip/vmware.xml","/CP065992_VMw.zip/metadata.zip/vibs/CP065992--2795774151834853535.xml","/CP065992_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065992_HPD4.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"22414565850210583866b2e24fe498d7","Name":"CP065992.zip","Release":"2025-03-07T06:43:07","Revision":"C","SHA1Sum":"9efd0a2fc4417b63d05f15cb5b3ec28d059f692e","SHA256Sum":"efdd3a0073a07f436068a83b1afff60cc13bfcbc7db0b2620cdac321d3839964","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065992","Version":"HPD4.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041510.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWUDB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:09:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5268232d10d445a596b065d77b66da67"}]},{"ProductId":"24bbe0adc4dc4c7385b6f5ad6aecf867","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL issued.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"9518012","DateModified":"2025-05-14T05:24:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/CP066569.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066569.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066569.scexe"],"MD5Sum":"a369c800ba2741a4c1a6e8ede62f0484","Name":"firmware-hdd-8e1e8083c5-HPG3-5.1.x86_64.rpm","Release":"2025-05-14T10:13:17","Revision":"E","SHA1Sum":"0d244481ac9829e556ff9628ce84025590f21392","SHA256Sum":"f297ca4750994e3b2f05a4da6775a25ca4edf3fdf201ca3af524eaac1a450cc6","Size":"9MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043280.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:39:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ce8115f8811442d4a6f1cdb1889d6806"}]},{"ProductId":"C9113","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Lights-Out Management"},{"Lang":"ja","Value":"ソフトウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"软件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This smart component contains the HPE Lights-Out Online Configuration Utility which is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the operating system without requiring a reboot of the server."},{"Lang":"ja","Value":"このSmartコンポーネントには、サーバーを再起動しないでオペレーティングシステムからProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティである、HPE Lights-Outオンライン設定ユーティリティが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1254200","DateModified":"2024-10-10T05:06:15","FileList":["cp063854.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"MD5Sum":"a270d8ca0100f2f15a6bff5ae0b1beea","Name":"cp063854.exe","Release":"2024-10-10T04:58:18","Revision":"A","SHA1Sum":"819d1089d38bb41cdaaf61aa6e75133465b7d070","SHA256Sum":"afbde3c95ffce49587664e302a989d8898ec0c91e15aec8c3b0d344304d168a1","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"TypeOfChange":"0","Version":"6.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":100,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Uninstall any older version of HPONCFG before installing this version of HPONCFG.</p><p>Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.</p><p>Click on the install button to install the utlility on the server. This does not require a reboot.</p><p>&nbsp;</p><p>&nbsp;</p><p>The utility will be installed in the program files under the directory HewlettPackardEnterprise\\HPONCFG\\</p><p>&nbsp;</p><p>&nbsp;</p><p>A shortcut for the graphical interface of the utility will be provided in &quot;Start Menu &gt; Programs &gt; HPE System Tools &gt; HPE Lights-Out Online Configuration Utility&quot;.</p>"},{"Lang":"ja","Value":"<p>HPONCFGのこのバージョンをインストールする前に、HPONCFGのすべての古いバージョンをアンインストールします。</p><p>コンポーネントを、ご使用のハードドライブの一時ディレクトリ内のディレクトリに置きます。ダブルクリックして実行します。</p><p>インストールボタンをクリックし、サーバーにユーティリティをインストールします。再起動は必要ありません。</p><p> </p><p> </p><p>ユーティリティは、HewlettPackardEnterprise\\HPONCFG\\ディレクトリの下にあるprogram filesにインストールされます</p><p> </p><p> </p><p>ユーティリティのグラフィカルインターフェイス用のショートカットが、スタートメニュー >プログラム > HPEシステムツール > HPE Lights-Outオンライン構成ユーティリティに提供されます。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions"},{"Lang":"ja","Value":"HPE Lights-Out オンライン構成ユーティリティfor Windows x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"160"},"SupportedDevices":[{"Dev":"B204","SubDev":"B206","SubVen":"0E11","TargetGUID":"a6b1a447-382a-5a4f-0e11-b2040e11b206","Type":"pci","Ven":"0E11"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Id":"5219994","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3306103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3307103c3381","Type":"pci","Ven":"103C"},{"Dev":"3308","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3308103c3381","Type":"pci","Ven":"103C"},{"Dev":"3300","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3300103c3381","Type":"pci","Ven":"103C"},{"Dev":"3301","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3301103c3381","Type":"pci","Ven":"103C"},{"Dev":"3302","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3302103c3381","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103c"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"Essentials","Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012 Essentials","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-09T06:41:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Introduced support for iLO 6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Introduced support for iLO 6.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Introduced support for iLO 6.</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>Introduced support for iLO 6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>iLO 6のサポートを開始しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Introduced support for iLO 6.</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.0"}],"SWKeys":[{"Name":"hponcfg.exe","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I15","Model":"HP ProLiant BL460c Server"},{"Family":"","Model":"HP StorageWorks 600 All-in-One Storage System"},{"Family":"W04","Model":"HP ProLiant DL320s Storage Server"},{"Family":"","Model":"HP StorageWorks 1200 All-in-One Storage System"},{"Family":"P64","Model":"HP ProLiant DL360 G6 Server"},{"Family":"A26","Model":"HP ProLiant BL465c Gen8 Server"},{"Family":"I31","Model":"HP ProLiant BL460c Gen8 Server"},{"Family":"I30","Model":"HP ProLiant BL420c Gen8 Server"},{"Family":"I31","Model":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"Family":"A28","Model":"HP ProLiant DL385p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL380e Gen8 Server"},{"Family":"P70","Model":"HP ProLiant DL380p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL360e Gen8 Server"},{"Family":"P71","Model":"HP ProLiant DL360p Gen8 Server"},{"Family":"J05","Model":"HP ProLiant DL320e Gen8 Server"},{"Family":"J03","Model":"HP ProLiant DL160 Gen8 Server"},{"Family":"J02","Model":"HP ProLiant ML350e Gen8 Server"},{"Family":"P72","Model":"HP ProLiant ML350p Gen8 Server"},{"Family":"J04","Model":"HP ProLiant ML310e Gen8 Server"},{"Family":"P74","Model":"HP ProLiant SL4540 Gen8 3 Node Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL250s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL230s Gen8 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"I32","Model":"HP ProLiant BL660c Gen8 Server"},{"Family":"P79","Model":"HP ProLiant DL580 Gen8 Server"},{"Family":"P77","Model":"HP ProLiant DL560 Gen8 Server"},{"Family":"P80","Model":"HP ProLiant DL320e Gen8 v2 Server"},{"Family":"P78","Model":"HP ProLiant ML310e Gen8 v2 Server"},{"Family":"P83","Model":"HP ProLiant SL210t Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 SE Server"},{"Family":"J06","Model":"HP ProLiant MicroServer Gen8"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"P94","Model":"HP ProLiant XL220a Gen8 v2 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"P88","Model":"HP ProLiant ML10 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"dfda885bb8ad4f4787ee362930d77b06"}]},{"ProductId":"88920b6128524213bc79e665d9b3a53b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2022 and Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2022 and Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.221.0</li><li>&nbsp;iSCSI Offload Driver 7.14.19.0</li><li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.7.0</li><li>&nbsp;Network Adapter NDIS VBD Client 7.13.220.0&nbsp;</li><li>&nbsp;FCoE Offload driver&nbsp;7.14.25.0</li><li>&nbsp;FCoE Crash Dump Driver 7.13.8.0</li></ul>"},{"Lang":"ja","Value":"<p>This component contains the following drivers:</p><ul><li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.221.0</li><li>&nbsp;iSCSI Offload Driver 7.14.19.0</li><li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.7.0</li><li>&nbsp;Network Adapter NDIS VBD Client 7.13.220.0&nbsp;</li><li>&nbsp;FCoE Offload driver&nbsp;7.14.25.0</li><li>&nbsp;FCoE Crash Dump Driver 7.13.8.0</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.221.0</li><li>&nbsp;iSCSI Offload Driver 7.14.19.0</li><li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.7.0</li><li>&nbsp;Network Adapter NDIS VBD Client 7.13.220.0&nbsp;</li><li>&nbsp;FCoE Offload driver&nbsp;7.14.25.0</li><li>&nbsp;FCoE Crash Dump Driver 7.13.8.0</li></ul>"}],"Files":[{"Bytes":"3468824","DateModified":"2025-02-13T07:53:16","FileList":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp064708.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"MD5Sum":"f8cce93cb5d141becbd5c014cb8a17a1","Name":"cp064708.exe","Release":"2025-02-13T07:37:34","Revision":"C","SHA1Sum":"8284c193419c33c065ecf4107a4a69f7346e2d4f","SHA256Sum":"b726e60fa7fb4b35d39f9ff276766c5a74fdfbd8a153c5e5b4ba7ffcdfc1f207","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"TypeOfChange":"1","Version":"7.13.221.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AD","SubDev":"2231","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c2231","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-09T08:21:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with Windows firmware component 5.3.6.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Windowsファームウェアコンポーネント5.3.6.0との互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with Windows firmware component 5.3.6.0.</p>","Fixes":"","Lang":"cn"}],"Version":"7.13.206.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"7.13.221.0"}],"SWKeys":[{"Name":"evbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f3e27b40cbd44b219097b667169a699f"}]},{"ProductId":"ff59337dd3ff4f44928eba3219e493a5","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_PM9A3U3HPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304b59445054","Version":"HPK4"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_PM9A3U3HPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304b59445055","Version":"HPK4"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_PM9A3U3HPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304b59445056","Version":"HPK4"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_PM9A3U3HPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304b59445141","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3167393","DateModified":"2024-07-09T04:37:14","FileList":["payload.json","Samsung_PM9A3_PM9A3U3HPK4.HPb","Samsung_PM9A3_PM9A3U3HPK4.xml"],"MD5Sum":"f1ec030a2f28edefcd7c739f084fa8e1","Name":"Samsung_PM9A3_PM9A3U3HPK4.fwpkg","Release":"2024-07-09T04:33:24","Revision":"","SHA1Sum":"e0d55f25d83f48e0197d10717821bdc160ca8098","SHA256Sum":"e70d468a83c465c6116c0636405b8a33404a66dc9e021a0128c2d39a38ce33f5","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VK000960KYDPT","TargetGUID":"562340a5-304b-3030-3936-304b59445054","Type":"nvme"},{"Id":"VK001920KYDPU","TargetGUID":"562340a5-304b-3130-3932-304b59445055","Type":"nvme"},{"Id":"VK003840KYDPV","TargetGUID":"562340a5-304b-3330-3834-304b59445056","Type":"nvme"},{"Id":"VK007680KYDQA","TargetGUID":"562340a5-304b-3730-3638-304b59445141","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T00:59:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung U.3 NVMe SSD with HPK4.</li></ul>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"VK000960KYDPT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK001920KYDPU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK003840KYDPV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK007680KYDQA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"360da88ee2a44682bb76e21ea11b52c4"}]},{"ProductId":"41c374eaf1f14df3b6eb451ccf1a1aaf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6016237","DateModified":"2025-05-14T08:16:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/CP066554.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066554.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066554.scexe"],"MD5Sum":"bcba9f190b44f1b92a5916a069842e6c","Name":"firmware-hdd-7a1edae8e7-HPG1-7.1.x86_64.rpm","Release":"2025-05-14T13:05:07","Revision":"G","SHA1Sum":"9abc4ac414e72b40450cc271181f56ad800483ac","SHA256Sum":"9e8cd6661ba712dcb2fc4ba84155267fb75b7dc52cf8d93e7059408995b84efa","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:30:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a884945cece648b9b982930d7d333344"}]},{"ProductId":"cb3ccbb54e5e4346a7916c413650fffc","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK3"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK3"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960KWVBR, VO001920KWVBT and VO003840KWVBU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3903416","DateModified":"2025-01-11T00:57:13","FileList":["cp064862.xml","cpqsetup.exe","KACD5ALSHPK3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"9331da97d6ee274a65ad4bb277830d11","Name":"cp064862.exe","Release":"2025-01-11T00:53:02","Revision":"B","SHA1Sum":"1ea2e7dda8282a0c7a3d99fc37e085944d3b8a0e","SHA256Sum":"0804c15d887716b9bb4f74eb48d42ac6cbbc3676e4e85536db1c37ea65fd5107","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO000960KWVBR","TargetGUID":"562340a5-304f-3030-3936-304b57564252","Type":"nvme"},{"Id":"VO001920KWVBT","TargetGUID":"562340a5-304f-3130-3932-304b57564254","Type":"nvme"},{"Id":"VO003840KWVBU","TargetGUID":"562340a5-304f-3330-3834-304b57564255","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T10:16:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWVBR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWVBT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWVBU","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bdae23eafeec40f9bfd04179e6c4d4ba"}]},{"ProductId":"605b084308a74c74a0091e855e41c6f1","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 8.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 8.0上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"31690165","DateModified":"2025-04-23T06:39:04","FileList":["/CP066778.vmexe64","/CP066778.vmfile","/CP066778.xml","/CP066778_VMw.zip","/payload.json","/CP066778_VMw.zip/index.xml","/CP066778_VMw.zip/vendor-index.xml","/CP066778_VMw.zip/metadata.zip","/CP066778_VMw.zip/vib20/CP066778/HPE_bootbank_CP066778_1.0.0-8.0.0.21495797.vib","/CP066778_VMw.zip/metadata.zip/vendor-index.xml","/CP066778_VMw.zip/metadata.zip/vmware.xml","/CP066778_VMw.zip/metadata.zip/vibs/CP066778--8769638589256880284.xml","/CP066778_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066778_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"772080fafdcab733833a47abbe7a7b70","Name":"CP066778.zip","Release":"2025-04-23T06:40:12","Revision":"","SHA1Sum":"80ae1f8b09b38bede9b754471fa360efa5d2fd21","SHA256Sum":"decb2a31f0af29b69c5d3662181fff8683aa43c0fe692787a5683cf54543f90b","Size":"30MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.5","VibList":[{"Name":"CP066778","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。<br /> </p><p><strong>注記：</strong>CX5ネットワークアダプターファームウェアを16.21.1xxxまたは16.22.1xxx（またはそれ以前）から16.26.1xxx（またはそれ以降）にアップグレードするには、中間ファームウェアバージョンとして16.23.1xxxまたは16.24.1xxxまたは16.25.1xxxを使用してください。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（ESXi 8.0）for HPE Mellanox VPI（EthernetおよびInfinibandモード）ConnectX4およびConnectX5デバイス - VMware ESXi 8.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T12:25:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.5"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c27e7b6a7ce048418c000ae5896267d9"}]},{"ProductId":"7e6f42aebfdb4390968da43b36518880","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3246976","DateModified":"2025-01-10T10:32:14","FileList":["cp065028.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXe0HPD8.REL"],"MD5Sum":"bfa1dc6b862ab131e51dd7020011de3f","Name":"cp065028.exe","Release":"2025-01-10T10:27:31","Revision":"D","SHA1Sum":"a616b0e25a88cadad3585d900d262b598ec2e7ff","SHA256Sum":"f597b941a776ccfadaca4d7273f879f0ec84b50ce625841a2fe5d8e543b3b401","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"},{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:17:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"edf000709f074a1fbe494396102a5993"}]},{"ProductId":"d152e4f9638d4a6a962a3424ad625ef5","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17908828","DateModified":"2025-03-24T03:36:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/A41_3.50_03_21_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/CP066443.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.50_2025_03_21-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066443.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066443.scexe"],"MD5Sum":"06d7c27930f7c4543872a0bb9d6a39b9","Name":"firmware-system-a41-3.50_2025_03_21-1.1.x86_64.rpm","Release":"2025-03-24T08:27:54","Revision":"","SHA1Sum":"c2ce516bc4e250e1ce725a198ba110d708a38cd9","SHA256Sum":"3ef16f9193b8fdded72dbb9ecaa7915b288d01437ad11a00099f055ab6867e0d","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプすることにより、hpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL325 Gen10 (A41)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:27:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b0493928a85b48aba125332060683d8b"}]},{"ProductId":"eb66fafd28ff4c39a42b91395104bd05","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4926008","DateModified":"2025-06-10T09:22:15","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"MD5Sum":"44e7818b481796683330901dc72eb192","Name":"qlgc-qla2xxx-kmp-default-10.02.14.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-06-10T07:23:03","Revision":"","SHA1Sum":"8d3f98b5cd6dd3892337a302979c3610c39623e6","SHA256Sum":"6619fe737ad2578fa17b719c74d1e1f94155e1cf0756f86470132278a172ed9e","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.14.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.14.21_150400.22-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br /><br />                    # rpm -Uvh qlgc-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.14.21_150400.22-1.sles15sp5.x86_64.rpm</p><p>4.  インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br /><br />                    セットアップが完了しました。コンピューターをただちに再起動してください。</p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                    # rpm -e qlgc-qla2xxx-<version>.<OSupdate>.x86_64</p><p>同じドライバーバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります</p><p>例：rpm –Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm --reinstall</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p> </p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.14.21_150400.22-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:54:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.13.03-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーをバージョン10.02.13.03-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.13.03-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.13.03-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"}],"SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"80e5ba3fa3874c0ebbc4c25180551fbd"}]},{"ProductId":"564f69c570d840a495455ed14f4ea38f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 8.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"QLogic driver for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"870027","DateModified":"2024-08-01T07:39:02","FileList":["/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip","/cp062113.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.82.1-1OEM.800.1.0.20613240.vib","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/vibs/qlnativefc--6796046031387820499.xml","/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240_24023049.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.82.1-1OEM.800.1.0.20613240.xml"],"MD5Sum":"cf9c5d965b4a9eb599507f6e8bbbff2d","Name":"cp062113.zip","Release":"2024-08-01T07:37:51","Revision":"","SHA1Sum":"5b3dfb4c9f1bec7ccd3e23813083c8beb7725dbf","SHA256Sum":"01f39a96b78b7f3b26b690dd18333ccf4d93d3334d6582e53241ccf8b55396fe","Size":"849KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2024.09.01","VibList":[{"Name":"qlnativefc","Version":"5.4.82.1-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-04T06:25:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.82.1</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Driver version 5.4.82.1</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.82.1</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2024.09.01"}],"SWKeys":[{"Name":"qlnativefc:5.4.82.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.82.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2be6fee6bf3d4f7d99b86151f18b3b5f"}]},{"ProductId":"a6fc6d419cd14563aeefb1d3f50c589e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17437456","DateModified":"2025-05-20T12:16:58","FileList":["cp067161.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U61_2.40_05_16_2025.signed.flash"],"MD5Sum":"0d3b51517b11ab17b735467d47e0c822","Name":"cp067161.exe","Release":"2025-05-20T12:13:54","Revision":"","SHA1Sum":"80903679900ded578e98842c38accbc0d2317d0b","SHA256Sum":"3d26400ce8ba09541dd1583b39fee87c6f2d38afc3a6c4e937258c2a85c757bc","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:29:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a1427232ff1d4c0ba936b0aec7c2e924"}]},{"ProductId":"1d54c8dcf99741aabe78b8a4e54d84f8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6203170","DateModified":"2025-05-14T07:44:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/CP066573.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066573.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066573.scexe"],"MD5Sum":"1632152aeca56bda4c511746ebecc1e2","Name":"firmware-hdd-10385ef3e6-HPD2-14.1.x86_64.rpm","Release":"2025-05-14T12:33:43","Revision":"N","SHA1Sum":"23865a5852e91b2f9c52e9b9576ec8a762bc790c","SHA256Sum":"e272063295743613cd1992b48e178e9e67404d20101ab48ca9046d396824fda0","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041452.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:56:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9d08a0ade192465ca089f5f2bbc4d87c"}]},{"ProductId":"cd1eb2802ed24b6aa04d98effb166b0e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD4"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD4"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD4"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD4"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD4"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD4"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD4"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD4"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD4"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD4"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD4"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19584870","DateModified":"2025-03-06T05:54:44","FileList":["/CP065931_BUILD_4.data","/CP065931.vmexe64","/CP065931.vmfile","/CP065931_VMw.zip","/CP065931.xml","/payload.json","/CP065931_VMw.zip/index.xml","/CP065931_VMw.zip/vendor-index.xml","/CP065931_VMw.zip/metadata.zip","/CP065931_VMw.zip/vib20/CP065931/HPE_bootbank_CP065931_HPD4.4-1OEM.800.1.0.20613240.vib","/CP065931_VMw.zip/metadata.zip/vendor-index.xml","/CP065931_VMw.zip/metadata.zip/vmware.xml","/CP065931_VMw.zip/metadata.zip/vibs/CP065931--2946736449188951223.xml","/CP065931_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065931_HPD4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"75706007483265908df8c962975ea99c","Name":"CP065931.zip","Release":"2025-03-06T05:53:52","Revision":"B","SHA1Sum":"36815e04fcb08c23afd857764e74430d054cdc67","SHA256Sum":"8c93f95a1b4a58ea6507cdfd29c7fcb8bcb38e41de8e77f15b5e2d1889318d25","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065931","Version":"HPD4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:09:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"69fa4a593266475d820dd2aa8799727f"}]},{"ProductId":"a07f8ac11b4a440d99aa61ea5fb0b63f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"ja","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"},{"Lang":"cn","Value":"<p>This product contains NIC driver version&nbsp;233.0.156.0 and RoCE driver version&nbsp;233.0.156.0.</p>"}],"Files":[{"Bytes":"457219","DateModified":"2025-04-09T02:03:22","FileList":["/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip","/cp066625.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_233.0.156.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_233.0.156.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vibs/bnxtroce--7165695560035088176.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/vibs/bnxtnet--3231861591349352780.xml","/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240_24674977.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_233.0.256.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"9f714502627bae07b0a7cc3b5f0a091d","Name":"cp066625.zip","Release":"2025-04-09T02:03:12","Revision":"","SHA1Sum":"c34b48c48271970c1fa6dffc4a9f516ad7ec4a2a","SHA256Sum":"e20d7c6c29b41b37a0918822dc914777eabd3b2fb6a7ccdec73c73db44e7ea22","Size":"446KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"bnxtroce","Version":"233.0.156.0-1OEM.800.1.0.20613240"},{"Name":"bnxtnet","Version":"233.0.156.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to add support for Tunnel based TPA (TCP Packet Aggregation).</li><li>This product enhances the coredump feature for generating the summary of a coredump file.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>この製品は、トンネルベースのTPA (TCP パケット集約) のサポートを追加するように強化されています。</li><li>この製品は、コアダンプファイルの概要を生成するためのコアダンプ機能を強化します。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to add support for Tunnel based TPA (TCP Packet Aggregation).</li><li>This product enhances the coredump feature for generating the summary of a coredump file.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:233.0.256.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:233.0.156.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:233.0.156.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bf90c15126a5436c885e1096952f2557"}]},{"ProductId":"4de9a363a422456faca983d193ca352a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612216","DateModified":"2025-04-18T11:39:55","FileList":["payload.json","U31_3.50_04_17_2025.signed.flash","U31_3.50_04_17_2025.xml"],"MD5Sum":"f2d5e2bce7569b2958910a5b04478721","Name":"U31_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"3391a0c261acd952db80bb3c7c729b9f49bd2ff5","SHA256Sum":"fa9ea2fb788ae56763088d3e61e75af86d5ce37695b4fd2855941f1f54e3b224","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"aca561b575c64b9ebd864d508122c62a"}]},{"ProductId":"cfe4c5a213fb4be397a8b588efd29cc1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p><p><strong>Previous Version of Firmware:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp; &nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p><p><strong>Previous Version of Firmware:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp; &nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20646243","DateModified":"2025-03-07T06:34:19","FileList":["/CP065934_BUILD_3.data","/CP065934.vmexe64","/CP065934.vmfile","/CP065934_VMw.zip","/CP065934.xml","/payload.json","/CP065934_VMw.zip/index.xml","/CP065934_VMw.zip/vendor-index.xml","/CP065934_VMw.zip/metadata.zip","/CP065934_VMw.zip/vib20/CP065934/HPE_bootbank_CP065934_HPG1.3-1OEM.800.1.0.20613240.vib","/CP065934_VMw.zip/metadata.zip/vendor-index.xml","/CP065934_VMw.zip/metadata.zip/vmware.xml","/CP065934_VMw.zip/metadata.zip/vibs/CP065934-3814721435429991454.xml","/CP065934_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065934_HPG1.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4d5e9f6a15c48055215cc5bb33c07b5b","Name":"CP065934.zip","Release":"2025-03-07T06:33:27","Revision":"K","SHA1Sum":"ae4a522d8ed9bf8e0bbade4c1e50c1b8868ce67a","SHA256Sum":"e12b0c594afc4648294df325e6dede07d52755397a4108bf57b72f3f37c2c414","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065934","Version":"HPG1.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041520.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p><br /><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p><br /><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWKGR ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:48:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8ac58cbcb5c54055b4aeda91c2755e86"}]},{"ProductId":"e485f42530b84989a3373bff82088143","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Operating System - Enhancements"},{"Lang":"ja","Value":"オペレーティング システム - 拡張"},{"Lang":"cn","Value":"操作系统 - 增强功能"}],"Description":[{"Lang":"en","Value":"This components installs the AMD PSHED service"},{"Lang":"ja","Value":"このコンポーネントはAMD PSHEDサービスをインストールします"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"628408","DateModified":"2024-07-12T14:43:14","FileList":["cp062258.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"MD5Sum":"c18738b151b4c5a957f9ff5c76f181ae","Name":"cp062258.exe","Release":"2024-07-12T14:41:28","Revision":"","SHA1Sum":"037c342252a6b1686f4d87dc6f51a9a6cd376340","SHA256Sum":"578e150ca930f79eebfb0b661ce30e48c971f62ef37fa9b753c52d9f812d9fcb","Size":"613KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"AMD PSHED Plug-in service for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"AMD PSHEDプラグインサービスfor Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-12T14:29:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Driver update</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>ドライバーアップデート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Driver update</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.50"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Driver update</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Driver update</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Driver update</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"}],"SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Cray XD295v"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b9cc1c533a1a4a64afbf1649fefcd8dc"}]},{"ProductId":"c101b138be5d4ee79271a6725d6813d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp; &nbsp; &nbsp; &nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ<br /> <br /><strong>リリースバージョンおよび/または日付：</strong><br />      GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />         GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />         GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの依存関係：<br />       </strong>なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>機能強化/新しい機能：</strong></p><p>       なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点：</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     </strong>なし</p>"}],"Files":[{"Bytes":"20418203","DateModified":"2025-03-06T05:28:54","FileList":["/CP065953_BUILD_3.data","/CP065953.vmexe64","/CP065953.vmfile","/CP065953_VMw.zip","/CP065953.xml","/payload.json","/CP065953_VMw.zip/index.xml","/CP065953_VMw.zip/vendor-index.xml","/CP065953_VMw.zip/metadata.zip","/CP065953_VMw.zip/vib20/CP065953/HPE_bootbank_CP065953_GPK7.3-1OEM.800.1.0.20613240.vib","/CP065953_VMw.zip/metadata.zip/vendor-index.xml","/CP065953_VMw.zip/metadata.zip/vmware.xml","/CP065953_VMw.zip/metadata.zip/vibs/CP065953-2079051419382020176.xml","/CP065953_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065953_GPK7.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b3b3d389b3405016c55f2cf1c6d7a13a","Name":"CP065953.zip","Release":"2025-03-06T05:28:07","Revision":"C","SHA1Sum":"1ba98f25cc33db7aeb62585f0b5f558eca9f23b0","SHA256Sum":"90ae9e5ebe8820edc3ec917667dbb2508c1316350eace1dbf6dcdc60176f3b3b","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK7","VibList":[{"Name":"CP065953","Version":"GPK7.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9,0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9,0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:38:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"839fbb262e4b4880914a769c2c486850"}]},{"ProductId":"824707fd6d4844feaef370452b0a3a3e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9021315","DateModified":"2025-05-20T20:52:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/CP067185.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/U44_3.60_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.60_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067185.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067185.scexe"],"MD5Sum":"a771b6793e149e39f4fca4d92250d8a0","Name":"firmware-system-u44-3.60_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-21T01:42:34","Revision":"","SHA1Sum":"4c2eefa391b64e1dea09ccb5ab80fef25a601a62","SHA256Sum":"927d7d6bcdbdb3f6afd4ff947d51df18d1a5a604ddfb0cc0fb90f4d1060f92a5","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:48:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d7c272a7ecd44c2c8a207d1e6c7aaad9"}]},{"ProductId":"6aac2d7fdad54ca7910ee0bb1e81d6f3","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200 1p OSFP MCX75310AAS Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_45_1200-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30074","Version":"28.45.1200"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ for HPE InfiniBand NDR200 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B21およびP45642-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported NDR200 cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>NDR200 HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>NDR200 HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるNDR200ケーブルおよびトランシーバー：</strong></p><p> </p><p><strong>NDR200 HCA対スイッチ：</strong></p><ul><li>P45698-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B24        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B25        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B26        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B23        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B21        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P49766-B21        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード3mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B22        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード5mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B23        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード10mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B24        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード15mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B25        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード20mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B26        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード30mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li></ul><p><strong>NDR200 HCA側トランシーバー：</strong></p><ul><li>P49764-B21        HPE InfiniBand NDR/Ethernet 1x400Gb OSFPマルチモード50m HCA側トランシーバー（HCAマルチモード光ファイバートランシーバー）</li></ul><p><br />注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported NDR200 cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>NDR200 HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>NDR200 HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"9062653","DateModified":"2025-06-10T09:52:16","FileList":["28_45_1200-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","28_45_1200-MCX75310AAS-HEAT_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"314fa7890b0698b3f6172cf4331c3743","Name":"28_45_1200-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","Release":"2025-06-10T09:49:50","Revision":"","SHA1Sum":"14757d845cb9db87d470edcb67c431c348869cce","SHA256Sum":"3f59f0e85f7c123f5842c2d0dc0f832a76c39efad475629c8097f40a98b28ded","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30074"],"TypeOfChange":"1","Version":"28.45.1200"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG) for HPE InfiniBand NDR200 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B21およびP45642-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1021","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30074","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-02T07:01:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.44.1036:</strong></p><ul><li>Increased the RX lossless buffer size to delay the transmission of Pause/PFC frames during NIC congestion.</li><li>Added a new mechanism for allocations and deallocations flows to enhance parallelism.</li><li>When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Added support for a new synchronized flow, including a tool and driver, to perform a fwreset on setups with a PCIe switch configuration.</li><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added support for new MADs: PortRecoveryPolicyConfig and PortRecoveryPolicyCounters . During the PHY recovery process, the firmware core will indicate the &nbsp;port_logical_state as Active.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 28.44.1036:</strong></p><ul><li>Cable info semaphore deadlock.</li><li>Improper error handling for the TLV full list, which caused the TLV mechanism to hang.</li><li>The SPDM GET_CERTIFICATE operation did not support all certificate chain offsets and chunk sizes.</li><li>An issue in VDPA where destroying a virtq would cause a health buffer syndrome with ext_synd=0x8f33 if the virtq was created without an mkey or with unmanned and mapped mkeys during live migration.</li><li>The VDPA feature bits GUEST_TSO4 and GUEST_TSO6 were unexpectedly set by default, leading to traffic interruptions.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン28.44.1036には、以下の新機能と変更が含まれます。</strong></p><ul><li>NIC輻輳時にPause/PFCフレームの送信を遅延させるために、RXロスレスバッファーサイズを増やしました。</li><li>並列処理を強化するために、割り当てフローと割り当て解除フローの新しいメカニズムを追加しました。</li><li>マルチホスト展開を使用する場合、各ホストには固有のポートとPFが割り当てられ、独自のLAGを管理します。</li><li>PCIeスイッチ構成のセットアップでfwresetを実行するためのツールとドライバーを含む新しい同期フローのサポートが追加されました。</li><li>同じPF上の異なるVF間で統合PTPがサポートされるようになりました。</li><li>新しいMADのサポートが追加されました: PortRecoveryPolicyConfigおよび PortRecoveryPolicyCounters 。PHY 回復プロセス中、ファームウェアコアはport_logical_stateをActiveとして示します。</li><li>新しいNV構成 (SM_DISABLE、デフォルト0) が追加されました。これを有効にすると、SMから発信されていないSMPトラフィックがブロックされます。</li><li>PFCCアクセスレジスターのパラメーターとしてケーブル長を設定する機能を追加しました。ケーブルの長さは、サイズ、Xoff、Xon しきい値などの RXロスレスバッファーパラメーターの計算に使用されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン28.44.1036で修正されました。</strong></p><ul><li>ケーブル情報セマフォのデッドロック。</li><li>TLV完全リストのエラー処理が不適切だったため、TLVメカニズムがハングしました。</li><li>SPDM GET_CERTIFICATE操作は、すべての証明書チェーンのオフセットとチャンクサイズをサポートしていませんでした。</li><li>VDPAにおける問題で、virtqがmkeyなしで作成された場合、またはライブマイグレーション中に人を介さずマッピングされたmkeyで作成された場合、virtqを破棄するとext_synd=0x8f33でヘルスバッファー症候群が発生します。</li><li>VDPA機能ビットGUEST_TSO4およびGUEST_TSO6が予期せずデフォルトで設定され、トラフィックの中断が発生しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.44.1036:</strong></p><ul><li>Increased the RX lossless buffer size to delay the transmission of Pause/PFC frames during NIC congestion.</li><li>Added a new mechanism for allocations and deallocations flows to enhance parallelism.</li><li>When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Added support for a new synchronized flow, including a tool and driver, to perform a fwreset on setups with a PCIe switch configuration.</li><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added support for new MADs: PortRecoveryPolicyConfig and PortRecoveryPolicyCounters . During the PHY recovery process, the firmware core will indicate the &nbsp;port_logical_state as Active.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 28.44.1036:</strong></p><ul><li>Cable info semaphore deadlock.</li><li>Improper error handling for the TLV full list, which caused the TLV mechanism to hang.</li><li>The SPDM GET_CERTIFICATE operation did not support all certificate chain offsets and chunk sizes.</li><li>An issue in VDPA where destroying a virtq would cause a health buffer syndrome with ext_synd=0x8f33 if the virtq was created without an mkey or with unmanned and mapped mkeys during live migration.</li><li>The VDPA feature bits GUEST_TSO4 and GUEST_TSO6 were unexpectedly set by default, leading to traffic interruptions.</li></ul>","Lang":"cn"}],"Version":"28.44.1036"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"cn"}],"Version":"28.45.1200"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"cd1831139a214326bb39c8b766008701"}]},{"ProductId":"6f77f9ef4381482fb9f00a79ce325ab3","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33598676","DateModified":"2025-03-24T08:27:48","FileList":["A40_3.50_03_21_2025.signed.flash","A40_3.50_03_21_2025.xml","payload.json"],"MD5Sum":"2a7d64bde3beb32e3ce573b5b52f659b","Name":"A40_3.50_03_21_2025.fwpkg","Release":"2025-03-24T08:24:22","Revision":"","SHA1Sum":"5298ea66563a210cccc304c74e6970e643ba9ce6","SHA256Sum":"e88ca1421de25274f03d9105d8a199669f06041e7d88e2898753bea4547ac428","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL385 Gen10（A40）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:24:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"abc4f0a644ef4d80b19b48c06d657bc1"}]},{"ProductId":"23c569ea92fb47f091a7a0c891acff72","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_44_1036-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.44.1036"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor Mellanox MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.44.1036</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.44.1036</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE&nbsp;(P25960-B21)</td><td>22.44.1036</td><td>MT_0000000437</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7695554","DateModified":"2025-04-11T07:16:14","FileList":["22_44_1036-MCX623106AS-CDA_Ax.pldm.signed","22_44_1036-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"MD5Sum":"6aec27a982b31746ef63d8f322ed2610","Name":"22_44_1036-MCX623106AS-CDA_Ax.pldm.fwpkg","Release":"2025-04-11T07:14:06","Revision":"","SHA1Sum":"3a0f5442ecc003b44b9570921c1bbc917660fbf4","SHA256Sum":"d844db0e07713381efbaadfa734a4c8eaa69a5db2c725bb468288bb8c2572e28","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"TypeOfChange":"1","Version":"22.44.1036"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）- MCX623106AS-CDAT Ethernet 100Gb 2ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-17T09:09:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry .</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action reduces the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li><li>Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Increased the maximum number of supported &quot;ARC-IN&quot; from 1 to 8 and &quot;ARCOUT&quot; from 3 to 8 for the dynamic flex parser.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>An upgrade issue that required firmware v22.36.1010 as an intermediate version when upgrading the firmware from v22.33.0428 or below to versions above 22.36.1010.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン22.43.1014には、以下の新機能と変更が含まれます。</strong></p><ul><li>VF移行中にCQドアベルが失われた場合に備えて回復手順を追加しました。</li><li>eSwitchマネージャーごとに選択されたすべての機能でエラーCQEイベントを示すオプションが追加されました。この表示は、エラーに関する関連情報 (シンドローム、function_id、タイムスタンプ、QP番号など) を含む新しいWQEとして定義されます。この機能は、新しい一般オブジェクトであるRDMA-Telemetryオブジェクトを使用して構成され、次の新しいキャップに依存します。</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_typesおよびHCA_CAP.rdma_telemetry。</p><ul><li>拡張カーネルロックダウン権限セット。新しいHCA機能ビットマスクフィールドtool_partial_capを使用して、ツール (権限TOOLS_RESORCES) によって次のサブ操作を呼び出すことができるようになりました。</li></ul><p style=\"margin-left:80px\">5つのサブ操作は次のとおりです。</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAPと他の機能</li><li>QUERY_VUIDと直接データ</li><li>QUERY_ROCE_ADDRESSと他のvport</li><li>SET_HCA_CAPと他の機能</li><li>POSTPONE_CONNECTED_QP_TIMEOUTと他のvport</li></ul><p style=\"margin-left:80px\">新しく追加された機能は次のとおりです。</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>ステアリングアクション (STC) の\"Jump To Flow\"テーブルパラメーターに'table_type_valid'および'table_type'フィールドが追加され、ユーザーがNIC_TXからFDB_TXにジャンプしてACLテーブルをバイパスできるようになりました。</li><li>さまざまなユースケースでNICドメインをバイパスすることでホップ削減を可能にしました。このようなアクションにより、大量のフローとデバイスを処理するためのホップ数が削減されます (PPSが向上します)。この新しい機能を有効にするために、テーブルのRX側にジャンプできるようにする新しいSTCアクションタイプ\"JUMP_TO_FDB_RX\"が追加されました。</li><li>LAGにグループ化された複数のE-SwitchにわたるQoSスケジューリングのサポートが追加されました。ある物理機能のVPortメンバーを、別の物理機能からのレートグループに追加することができ、グループのレート制限はそれらのVPortメンバーにも適用されます。</li><li>動的フレックスパーサーでサポートされる\"ARC-IN\"の最大数を1から8に、\"ARC-OUT\"の最大数を3から8に増やしました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン22.43.1014で修正されました：</strong></p><ul><li>create_sqが無効なmboxを使用した場合、セットアップがクラッシュする。これで、無効なmboxが有効なDBに置き換えられました。</li><li>ファームウェアをv22.33.0428以下から22.36.1010以上のバージョンにアップグレードするときに、中間バージョンとしてファームウェアv22.36.1010が必要になるアップグレードの問題。</li><li>FACTORYのデフォルトのNV構成値のクエリを修正しました。ファームウェアは常に適用される「次」値を返しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry .</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action reduces the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li><li>Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Increased the maximum number of supported &quot;ARC-IN&quot; from 1 to 8 and &quot;ARCOUT&quot; from 3 to 8 for the dynamic flex parser.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>An upgrade issue that required firmware v22.36.1010 as an intermediate version when upgrading the firmware from v22.33.0428 or below to versions above 22.36.1010.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"cn"}],"Version":"22.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"cn"}],"Version":"22.44.1036"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7f83057f63894465b43afc28bd847389"}]},{"ProductId":"6b2dbf58581246349103e902007d06c0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4051952","DateModified":"2025-01-11T12:21:13","FileList":["cp065088.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKETG3.rel"],"MD5Sum":"e4e72d1ff058b184bf9884d312f0582d","Name":"cp065088.exe","Release":"2025-01-11T12:16:53","Revision":"B","SHA1Sum":"3e523172209c92004162c36bc0681405e5e847dd","SHA256Sum":"cba8b3512d412a4ee02675b8ba7efdade6b961019674b0a164d3c643ff8e67c2","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:39:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"eb721bc9a6e6423e8e9b0917a2d244ec"}]},{"ProductId":"2b01702f6be343c09f8208f8aab17afb","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-a_Gen10P_52.32.3-6118_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.32.3-6118"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR216i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7507587","DateModified":"2025-06-13T14:12:16","FileList":["HPE_MR216i-a_Gen10P_52.32.3-6118_A.HPb","HPE_MR216i-a_Gen10P_52.32.3-6118_A.xml","payload.json"],"MD5Sum":"7f6cf425377ec47aaed237fe5c579927","Name":"HPE_MR216i-a_Gen10P_52.32.3-6118_A.fwpkg","Release":"2025-06-13T14:08:59","Revision":"","SHA1Sum":"5a6762335347916b7745c6de5304c87d0f4fde8c","SHA256Sum":"6421e9cd2809ee723889162092da4a89ec109140418c85684052c48a8175666f","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.32.3-6118"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR216i-a Gen10 Plusトライモードコントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The&nbsp;algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and arenot applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfishデバイス有効化機能強化: Redfish暗号化のサポートを追加(POST&PATCH）</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">注記: MRコントローラーはSEDのみをサポートします。したがって、Volume[EncryptionTypes]はPOST(作成)またはPATCH(アップデート)中に書き込みできません。それに応じて、次の注釈は入力されません。</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o 注記:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted]は、適格なボリュームに対してオプション「true」を指定してのみ発行できます。MRファームウェアではセキュアボリュームを非セキュアボリュームに変更できないため、オプション 'false' を指定した PATCH Volume[Encrypted] は失敗します。</li><li>POST (作成) 中に、RAIDType=Noneのボリュームを作成する場合、「暗号化」オプションは使用できません。これは、MRが1ステップで安全なJBODを作成することをサポートしていないためです。JBODを作成した後、PATCH Volume [Encrypted = true] を発行して安全なJBODを作成できます。</li><li>ユーザーがEKMへの変更を要求するたびに、UEFIドライバー経由でキーを取得するために再起動が必須になります。</li></ul><ul><li>MR408i-pのサポートを追加</li><li>UBM10バックプレーンのサポートを追加しました</li><li>FWアップデート中に中断が発生した場合、UBMコントローラーがブートローダ状態にあるときに、UBM バックプレーンFWバージョン表示とFWアップデートをサポートします。</li><li>マップ解除可能な論理ドライブ用の NVMe SSDをサポートします。SATA SSDは、マップ解除可能な論理ドライブではサポートされないことに注意してください。</li><li>NANDフラッシュリフレッシュの改善</li></ul><p style=\"margin-left:80px\">o 指定された日数後に「System reset required」というイベントを投稿するアルゴリズムが削除されました。更新は同じ指定された時間後に行われ、新しいイベントが以下のように入力されます。</p><ul><li style=\"margin-left: 80px;\">NANDフラッシュのリフレッシュを開始する前に: 「NAND refresh in progress:changing WB Logical Drives to WT」</li><li style=\"margin-left: 80px;\">NAND フラッシュのリフレッシュが完了したら、「NAND refresh complete:changing WT virtual disks to WB」</li><li style=\"margin-left: 80px;\">上記の動作はMR400コントローラーにのみ適用され、MR200コントローラーには適用されません。</li><li>RAID1整合性チェックイベント文字列の変更</li></ul><p style=\"margin-left:80px\">o イベント文字列が「Consistency Check found inconsistent parity on LD <Ld Id> at strip <Strip Number>」から「Consistency Check found inconsistency on LD <Ld Id> at strip <Strip Number>」に変更されました。</p><ul><li>シャットダウン時に構成されたドライブのスピンダウンを制御するための新しいコントローラープロパティ「Spin Down Drives At Shutdown」をサポートします。</li><li>SCSI NVMe変換レイヤー仕様バージョン1.14のサポート</li></ul>","Fixes":"<ul><li>修正 a00143232en_us: HPE MR Gen11 コントローラー - AMD EPYC 9xx5 2P構成のHPE ProLiant DL365/DL385 Gen11 サーバーでコンポーネント整合性ステータスがサポートされていないと表示される</li><li>修正 a00144054en_us: HPE MR Gen10 PlusおよびGen11ストレージコントローラー - システムが VMware ESXiオペレーティング システムを起動すると、SAS/SATA/NVMe ドライブファームウェアのアップデートが成功しない場合があります</li><li>修正 a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - 大量のI/OがアクティブなときにHPE MRSAに予期しない情報が表示される</li><li>CM7 FIPSドライブがSED対応ドライブとして識別されない問題を修正しました。CM7 FIPSドライブモデル番号: VO001920YXUHU、VO003840YXUHV、VO007680YXUJA、MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VV007680LYJKF、VV015360LYXMT、MV003200LYJKH、MV006400LYJKK。</li><li>無効なセキュリティキーを使用して外部ドライブをインポートすると、5回試行してもコントローラーが無限ループに陥る問題を修正しました。</li><li>PCI BARアップデートの進行中に MCTPトラフィックがあるとコントローラーがアサートする可能性がある問題を修正しました。</li><li>Redfish Drive.CapableSpeedGbsがSAS4ドライブに対して22.5ではなく22と表示される問題を修正しました。</li><li>ReuseTargetIdオプションを使用して同じコマンドで複数の論理ドライブを作成すると、作成される論理ドライブの数が予想よりも少なくなる問題を修正しました。</li><li>複数の論理ドライブ構成で固定キャッシュが生成されないことがある断続的な問題を修正</li><li>ホストのタスク管理によりオフライン ドライブ ファームウェアのダウンロードがタイムアウトしたにもかかわらず、ダウンロード完了イベントが生成されるというまれな問題を修正しました。</li><li>サーバーの起動前にキャッシュオフロードが発生すると、RAID5/50/6/60論理ドライブのパフォーマンスが低下する可能性がある問題を修正しました。</li><li>NVMeドライブでパトロール読み取りを実行しているときにコントローラーに障害が発生し、OCR (オンラインコントローラーリセット) で回復する可能性がある問題を修正しました。</li><li>NVMe JBODドライブの最大書き込み同一長または最大アンマップブロック記述子数が上書きされ、SCSI UNMAPまたはWRITE SAMEコマンドが失敗する問題を修正しました。</li><li>ホストが実行時に PCIe BARを構成すると、PCIeメモリ読み取りのUR(サポートされていない要求) が発生する可能性があるというまれな問題を修正しました。</li><li>0より大きく8より小さいパラメーターリストの長さを使用するSCSI UNMAPコマンドが、SCSIセンス キーの不正な要求とパラメーターリスト内の無効なフィールドの追加センスデータで失敗する問題を修正しました。</li><li>PCI bar初期化がブートメッセージ処理を待機してタイムアウトしたためにコントローラーがアサートされる可能性があるというまれな問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The&nbsp;algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and arenot applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"cn"}],"Version":"52.30.3-5917"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"cn"}],"Version":"52.32.3-6118"}],"SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"cd3679816f4245f5b73d4f4f5600d71d"}]},{"ProductId":"b1381f6ec67b40269898593ac27aca95","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"19973771","DateModified":"2025-03-06T09:05:10","FileList":["/CP066009_BUILD_4.data","/CP066009.vmexe64","/CP066009.vmfile","/CP066009_VMw.zip","/CP066009.xml","/payload.json","/CP066009_VMw.zip/index.xml","/CP066009_VMw.zip/vendor-index.xml","/CP066009_VMw.zip/metadata.zip","/CP066009_VMw.zip/vib20/CP066009/HPE_bootbank_CP066009_HPD8.4-1OEM.800.1.0.20613240.vib","/CP066009_VMw.zip/metadata.zip/vendor-index.xml","/CP066009_VMw.zip/metadata.zip/vmware.xml","/CP066009_VMw.zip/metadata.zip/vibs/CP066009--3345376133589604648.xml","/CP066009_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066009_HPD8.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f83b10a8d86623a241356502055d77ef","Name":"CP066009.zip","Release":"2025-03-06T09:04:26","Revision":"C","SHA1Sum":"ce8036397855a0b2eaecb7bc357ed7b45eb92ca2","SHA256Sum":"83ca550aac24808cb416370db6d31d2ad28fa91812aa41dadab37b785c45f9d7","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP066009","Version":"HPD8.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043266.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:07:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"671351a63ae9400183e592bce3be61ad"}]},{"ProductId":"ff242e39c275472185612592300114ce","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE QLogic FastLinQ 10/25/50 GbEサーバーアダプタードライバーfor Microsoft Windows Server 2022およびMicrosoft Windows Server 2025を含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>Marvell Windows FastLinQ Ethernet VBD, 8.72.21.0</li><li>Marvell Windows FastLinQ Ethernet VBD Client, 8.72.21.0&nbsp;</li><li>Marvell Windows FCoE Offload Driver, 8.70.3.0</li><li>Marvell Windows FCoE Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Offload Driver, 8.70.2.0</li></ul>"},{"Lang":"ja","Value":"<p>This component contains the following drivers:</p><ul><li>Marvell Windows FastLinQ Ethernet VBD, 8.72.21.0</li><li>Marvell Windows FastLinQ Ethernet VBD Client, 8.72.21.0&nbsp;</li><li>Marvell Windows FCoE Offload Driver, 8.70.3.0</li><li>Marvell Windows FCoE Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Offload Driver, 8.70.2.0</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>Marvell Windows FastLinQ Ethernet VBD, 8.72.21.0</li><li>Marvell Windows FastLinQ Ethernet VBD Client, 8.72.21.0&nbsp;</li><li>Marvell Windows FCoE Offload Driver, 8.70.3.0</li><li>Marvell Windows FCoE Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Crash-dump Driver, 8.58.2.0</li><li>Marvell Windows iSCSI Offload Driver, 8.70.2.0</li></ul>"}],"Files":[{"Bytes":"3575104","DateModified":"2025-03-19T10:17:15","FileList":["cp066297.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"MD5Sum":"33723fd687f8ea46920e51e377087bdb","Name":"cp066297.exe","Release":"2025-03-19T10:01:58","Revision":"B","SHA1Sum":"68793ee1d7bd925bca425cbafd085d5156abb63c","SHA256Sum":"675c4a6065a199613a212474c815bde7bebf3de529088699c9e5acb25642d685","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"Windows Server x64 Edition用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bf","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002be","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002c0","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021f","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021f","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021a","Type":"pci","Ven":"1077"},{"Dev":"8080","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80801590021b","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021a","Type":"pci","Ven":"1077"},{"Dev":"8084","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80841590021b","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021a","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T10:00:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Add Windows Server 2025 support.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"},{"ReleaseNotes":[{"Enhancements":"<p>Add Azure&nbsp;support.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Add Azure&nbsp;support.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Add Azure&nbsp;support.</p>","Fixes":"","Lang":"cn"}],"Version":"8.72.21.0"}],"SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2e40be73ca9441de949652bc7f259323"}]},{"ProductId":"4502e15e8e6c48d58b299fb45b3d1658","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.40 (05/16/2025)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16811155","DateModified":"2025-05-20T12:17:10","FileList":["payload.json","U64_2.40_05_16_2025.signed.flash","U64_2.40_05_16_2025.xml"],"MD5Sum":"4dac1e411f75331cb4aba0618a9d68ff","Name":"U64_2.40_05_16_2025.fwpkg","Release":"2025-05-20T12:13:57","Revision":"","SHA1Sum":"845720c70e1f304f5ed6535029649896e2a1ac60","SHA256Sum":"56d6e9442ecd2a8a0dfd861cb8e7d124f758996d4562735179da5fce8aad3e59","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant MicroServer Gen10 Plus v2 (U64)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:33:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"3298a6cb93f34849b91732757aaa5e47"}]},{"ProductId":"5e67b3914b754070a44558f816a7dbab","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1657672","DateModified":"2024-06-12T06:44:21","FileList":["cp061669.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","manifest_icea68.man","nicdrvr.dll"],"MD5Sum":"ca958b7ac00d286880fea60eb293641c","Name":"cp061669.exe","Release":"2024-06-12T06:28:55","Revision":"","SHA1Sum":"50b3efb9568646e0fcf46accbcf64c98b6d686c1","SHA256Sum":"6bbcbad8fa2d25e39b3b7523c9f8290828a1ff8bb2ff3f98889abeccf1afe860","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"TypeOfChange":"1","Version":"1.15.121.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel iceaドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel icea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-03T06:02:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Columbiaville 4.4.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Columbiaville 4.4のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Columbiaville 4.4.</p>","Fixes":"","Lang":"cn"}],"Version":"1.14.104.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.15.121.0"}],"SWKeys":[{"Name":"icea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"00cd9a0dfbc1457ea8fa7652f2810d78"}]},{"ProductId":"ccde97956825448f97ee8427bc2eccdb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."},{"Lang":"ja","Value":"HPE SmartアレイイSRベント通知サービスは、HPE SmartアレイSRコントローラードライバーを使用しているシステムで、64ビットMicrosoft Windows Serverシステムイベントログへのイベント通知をサポートします。"},{"Lang":"cn","Value":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"741784","DateModified":"2025-04-14T07:33:13","FileList":["cp066258.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"MD5Sum":"ab753042682006542c75cea6e8c6e9e5","Name":"cp066258.exe","Release":"2025-04-14T07:29:00","Revision":"C","SHA1Sum":"ec307549431f5ed8f83bea4c92af803d32403671","SHA256Sum":"4aae61e3bc1c8c5aa76b51bf2653a6ab4d780f00cbaed0a31b3e28f9ac52a8d6","Size":"724KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"TypeOfChange":"1","Version":"1.2.1.69"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/verbose_log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","SWKey":"SmartDQa.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"62.0.28.64"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"},{"Lang":"ja","Value":"HPE SmartアレイSRイベント通知サービス for Windows Server 64ビットEditions"},{"Lang":"cn","Value":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0655","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0655","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0701","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0701","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-17T10:21:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Azure Stack HCI 23H2 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Azure Stack HCI 23H2 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.1.69"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Fixed online force flash issue on OneView.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Fixed online force flash issue on OneView.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Fixed online force flash issue on OneView.</p>","Lang":"cn"}],"Version":"1.2.1.69"}],"SWKeys":[{"Name":"hpepqiesrv.exe","SWKeyExpectedPath":"%programfiles%\\hpe\\hpepqiesrv"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fa20d89096b14cd19137e51a191c98dc"}]},{"ProductId":"3e44af8bcf3140b3bef280f7e913e5b4","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58554a54","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58554a55","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58554a56","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58554b41","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58554a4e","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58554a50","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58554a51","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58554a52","Version":"HPK2"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b59475a51","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR, VO015360KYGZQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; -<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2125020","DateModified":"2024-05-22T12:21:14","FileList":["Kioxia_CD8_KACD8ALSHPK2.HPb","Kioxia_CD8_KACD8ALSHPK2.xml","payload.json"],"MD5Sum":"4d77aed5c56943877c8dbb93f253f639","Name":"Kioxia_CD8_KACD8ALSHPK2.fwpkg","Release":"2024-05-22T12:17:16","Revision":"","SHA1Sum":"161d5e6c35207d4d2116a654b641a66199a9c95c","SHA256Sum":"05cfb76092d81ad7955109b6463156b6bc52fd93d868246de9d783f855aace5f","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000800KXUJT","TargetGUID":"4d2340a5-304f-3030-3830-304b58554a54","Type":"nvme"},{"Id":"MO001600KXUJU","TargetGUID":"4d2340a5-304f-3130-3630-304b58554a55","Type":"nvme"},{"Id":"MO003200KXUJV","TargetGUID":"4d2340a5-304f-3330-3230-304b58554a56","Type":"nvme"},{"Id":"MO006400KXUKA","TargetGUID":"4d2340a5-304f-3630-3430-304b58554b41","Type":"nvme"},{"Id":"VO000960KXUJN","TargetGUID":"562340a5-304f-3030-3936-304b58554a4e","Type":"nvme"},{"Id":"VO001920KXUJP","TargetGUID":"562340a5-304f-3130-3932-304b58554a50","Type":"nvme"},{"Id":"VO003840KXUJQ","TargetGUID":"562340a5-304f-3330-3834-304b58554a51","Type":"nvme"},{"Id":"VO007680KXUJR","TargetGUID":"562340a5-304f-3730-3638-304b58554a52","Type":"nvme"},{"Id":"VO015360KYGZQ","TargetGUID":"562340a5-304f-3531-3336-304b59475a51","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-06-22T11:34:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This version of FW now supports the 15.36TB model and FW fixes of drive time-out/failures.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"MO000800KXUJT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXUJU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXUJV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXUKA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXUJN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXUJP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXUJQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXUJR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYGZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"38bbc6322f054a4b9d684698cc19c086"}]},{"ProductId":"e6ce1a91bd5b4f829c98f53210189206","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GWTFEおよびMB014000GWTFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18159022","DateModified":"2025-03-06T11:24:24","FileList":["/CP065997_BUILD_3.data","/CP065997.vmexe64","/CP065997.vmfile","/CP065997_VMw.zip","/CP065997.xml","/payload.json","/CP065997_VMw.zip/index.xml","/CP065997_VMw.zip/vendor-index.xml","/CP065997_VMw.zip/metadata.zip","/CP065997_VMw.zip/vib20/CP065997/HPE_bootbank_CP065997_HPG8.3-1OEM.800.1.0.20613240.vib","/CP065997_VMw.zip/metadata.zip/vendor-index.xml","/CP065997_VMw.zip/metadata.zip/vmware.xml","/CP065997_VMw.zip/metadata.zip/vibs/CP065997--6289260116304155993.xml","/CP065997_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065997_HPG8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"91449a3a0ef1b2c57a960a14353aaecc","Name":"CP065997.zip","Release":"2025-03-06T11:23:34","Revision":"C","SHA1Sum":"c5b2d48f2e6b42ee2ff1ee4900ae1b4029c1fc19","SHA256Sum":"0c29f91cacfdc8ced9b53f4d8247c128aaf5299dea34fd9114db2ef8d90bdccd","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"TypeOfChange":"1","Version":"HPG8","VibList":[{"Name":"CP065997","Version":"HPG8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042459.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000GWTFF","TargetGUID":"4d2340a5-3042-3431-3030-304757544646","Type":"sata"},{"Id":"MB012000GWTFE","TargetGUID":"4d2340a5-3042-3231-3030-304757544645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:33:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB012000GWTFE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWTFF","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a7b6d297e2744431a5a1d38a6c7ad857"}]},{"ProductId":"01e0939311154208bbd5b8d9e5157a9c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"cn","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"ja","Value":"Smart Storage Administrator CLI（SSACLI）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p><p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p><p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>SSA CLIコンソールに入るには、ssacliとタイプします。</p><p>SSA CLIコンソール以外からでも、構文ssacliを使用してコマンドを実行することができます。</p><p>使用方法について詳しくは、\"ssacli help\"とタイプするか、CLIプロンプト内で\"help\"とタイプしてください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p><p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p><p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"9130776","DateModified":"2025-04-09T07:57:13","FileList":["cp066718.xml","cpqsetup.exe","genericmsi.dll","SSACLI64580_X64.msi","SSACLI_RELNOTES.txt"],"MD5Sum":"d94a386c8e4077da15322ffd6339e99d","Name":"cp066718.exe","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"f92590fb703c33f22d68846faaf4ee6e3d16bf28","SHA256Sum":"427eedfe216c3a6adb7b108378a52d052b8fa4d68d3da6f809c8b68c3c726010","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI for Windows 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:34:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssacli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"72fa0e1d12dc41df90daddb7c56d33a7"}]},{"ProductId":"1188e33080924486b998a030d43acf6f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1544784","DateModified":"2025-04-01T02:21:17","FileList":["cp065291.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"a9237b03a77165fd8ad4f45a106bf492","Name":"cp065291.exe","Release":"2025-04-01T02:06:07","Revision":"B","SHA1Sum":"f9498b85e8c97cf8395e4ae3e11bdefa5f2119d2","SHA256Sum":"bbb6d964892b3f2c65eee11c15ce9f779ed0df6718050898d754cfc1800a8d85","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:39:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"41d34f66fae5472b9825cdeb5e4539fd"}]},{"ProductId":"509f54411aaa488d8ade3254836debf4","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58565948","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58565a44","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58565a45","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58565946","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58565a41","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58565a42","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b58565a43","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2384696","DateModified":"2024-11-12T08:15:20","FileList":["Kioxia_CM7_KACM7ALSHPK3.HPb","Kioxia_CM7_KACM7ALSHPK3.xml","payload.json"],"MD5Sum":"98a379c48127e2bb36ad4f1a8611a80e","Name":"Kioxia_CM7_KACM7ALSHPK3.fwpkg","Release":"2024-11-12T08:12:47","Revision":"","SHA1Sum":"c2b0b92ee247bc77c3227b8f16f0b9a0925803d4","SHA256Sum":"710416287f355e40f37946933b17e71eee3298fcf2fd0886ffa685bcc6e05314","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600KXVYH","TargetGUID":"4d2340a5-304f-3130-3630-304b58565948","Type":"nvme"},{"Id":"MO003200KXVZD","TargetGUID":"4d2340a5-304f-3330-3230-304b58565a44","Type":"nvme"},{"Id":"MO006400KXVZE","TargetGUID":"4d2340a5-304f-3630-3430-304b58565a45","Type":"nvme"},{"Id":"VO001920KXVYF","TargetGUID":"562340a5-304f-3130-3932-304b58565946","Type":"nvme"},{"Id":"VO003840KXVZA","TargetGUID":"562340a5-304f-3330-3834-304b58565a41","Type":"nvme"},{"Id":"VO007680KXVZB","TargetGUID":"562340a5-304f-3730-3638-304b58565a42","Type":"nvme"},{"Id":"VO015360KXVZC","TargetGUID":"562340a5-304f-3531-3336-304b58565a43","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-12T07:41:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"MO001600KXVYH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXVZD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXVZE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXVYF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXVZA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXVZB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KXVZC","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"3057a02626624a6b8dc331ea2b6655a8"}]},{"ProductId":"0a96bc740aee4364b774edfa452ca9a4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3247352","DateModified":"2025-01-10T10:11:15","FileList":["cp065027.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXn0HPD8.REL"],"MD5Sum":"badfc75b274bfef8dce58a308f6659e0","Name":"cp065027.exe","Release":"2025-01-10T10:05:54","Revision":"D","SHA1Sum":"e438a9598a0da45212b00556b85477c9a780d4b5","SHA256Sum":"35cb07bebcae8b10c7405ac5dbded4dcbb022c1f2f55c653c0ac87b773010de9","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:15:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ef72f30306c0422d8d29b83faf9f4af6"}]},{"ProductId":"27053985f2354572a6633cc6a63bb7ef","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_44_1036-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.44.1036"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージ - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.44.1036</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.44.1036</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td><td>26.44.1036</td><td>MT_0000000551</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7124137","DateModified":"2025-04-11T07:09:21","FileList":["26_44_1036-MCX631432AS-ADA_Ax.pldm.signed","26_44_1036-MCX631432AS-ADA_Ax.pldm.xml","payload.json"],"MD5Sum":"b2b9f673df4048eec7a4e9c92c41a55e","Name":"26_44_1036-MCX631432AS-ADA_Ax.pldm.fwpkg","Release":"2025-04-11T07:06:43","Revision":"","SHA1Sum":"46c3864b79b8a22adb2c063ab21bb35a9e2e6b6c","SHA256Sum":"14cdc3e6dda39f94b03bb2f5ffe9bbb591521469f614b99d2e2e19282452d488","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"TypeOfChange":"1","Version":"26.44.1036"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3.  iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）- Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-17T08:50:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry.</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action r educes the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。<br /> </p><p><strong>バージョン26.43.1014には、以下の新機能と変更が含まれます。</strong></p><ul><li>VF移行中にCQドアベルが失われた場合に備えて回復手順を追加しました。</li><li>eSwitchマネージャーごとに選択されたすべての機能でエラーCQEイベントを示すオプションが追加されました。この表示は、エラーに関する関連情報 (シンドローム、function_id、タイムスタンプ、QP番号など) を含む新しいWQEとして定義されます。この機能は、新しい一般オブジェクトであるRDMA-Telemetryオブジェクトを使用して構成され、次の新しいキャップに依存します。</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_typesおよびHCA_CAP.rdma_telemetry。</p><ul><li>拡張カーネルロックダウン権限セット。新しいHCA機能ビットマスクフィールドtool_partial_capを使用して、ツール (権限TOOLS_RESORCES) によって次のサブ操作を呼び出すことができるようになりました。</li></ul><p style=\"margin-left:80px\">5つのサブ操作は次のとおりです。</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAPと他の機能</li><li>QUERY_VUIDと直接データ</li><li>QUERY_ROCE_ADDRESSと他のvport</li><li>SET_HCA_CAPと他の機能</li><li>POSTPONE_CONNECTED_QP_TIMEOUTと他のvport</li></ul><p style=\"margin-left:80px\">新しく追加された機能は次のとおりです。</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>ステアリングアクション (STC) の\"Jump To Flow\"テーブルパラメーターに'table_type_valid'および'table_type'フィールドが追加され、ユーザーがNIC_TXからFDB_TXにジャンプしてACLテーブルをバイパスできるようになりました。</li><li>さまざまなユースケースでNICドメインをバイパスすることでホップ削減を可能にしました。このようなアクションにより、大量のフローとデバイスを処理するためのホップ数が削減されます (PPSが向上します)。この新しい機能を有効にするために、テーブルのRX側にジャンプできるようにする新しいSTCアクションタイプ\"JUMP_TO_FDB_RX\"が追加されました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン26.43.1014で修正されました：</strong></p><ul><li>create_sqが無効なmboxを使用した場合、セットアップがクラッシュする。これで、無効なmboxが有効なDBに置き換えられました。</li><li>FACTORYのデフォルトのNV構成値のクエリを修正しました。ファームウェアは常に適用される「次」値を返しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry.</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action r educes the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.<br />&nbsp;</p><p><strong>New features and changes included in version 26.44.1036:</strong></p><ul><li>Enabled the get_pf_mac_address function for all available PFs.</li><li>Enhanced traffic management of PTP packets to reduce their impact on regular network traffic.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 26.44.1036:</strong></p><ul><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"26.44.1036"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631432AS-ADAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"1c5dae6a3f044f1abd61c73dbd869087"}]},{"ProductId":"38437d438933420e8063d6e963ffd91f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5745028","DateModified":"2025-05-14T07:45:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/CP066574.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/SAVGRTG9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG9-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066574.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066574.scexe"],"MD5Sum":"5eb8358b9d594fc9baa0264aaa541ba4","Name":"firmware-hdd-ec908c3650-HPG9-6.1.x86_64.rpm","Release":"2025-05-14T12:34:03","Revision":"F","SHA1Sum":"33388224c3735a7b5b306758f5243c5932b05b39","SHA256Sum":"215d28d27ef86361147e79651cde651e141fe5bb0e1443f47311c5cc868941ae","Size":"5MB","TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9"}],"Installation":{"Command":"CP040273.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:58:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6ef23300d2f94eb5963698088cae87a4"}]},{"ProductId":"4c108242693848129dadc44c03c82865","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10Plus_1.0.0.22.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPS Innovation Engineファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8409359","DateModified":"2022-07-29T03:15:36","FileList":["IEGen10Plus_1.0.0.22.signed.bin","IEGen10Plus_1.0.0.22.xml","payload.json"],"MD5Sum":"65fee9d87a847901be74f8252583943b","Name":"IEGen10Plus_1.0.0.22.fwpkg","Release":"2022-07-29T03:11:54","Revision":"B","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ -  HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2022-08-14T09:31:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>なし</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(B) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"5ba2fe62306d406aae00e2995213020e"}]},{"ProductId":"d2753039facd45788d8eb7892e214eed","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD9"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JWTFD and MB012000JWTFC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JWTFD and MB012000JWTFC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5184233","DateModified":"2025-05-15T10:45:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/CP066515.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/TAMG07scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD9-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066515.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066515.scexe"],"MD5Sum":"4255ec9b387a45d8ec5a2b4753aff21e","Name":"firmware-hdd-4ba9615f90-HPD9-3.1.x86_64.rpm","Release":"2025-05-15T15:35:07","Revision":"C","SHA1Sum":"7a560c6a17542f6b011e62709516607043fde8a7","SHA256Sum":"c4845a1a27ba3bf2431f7eb94454334caeb9c3c82cd76574a5fd86daf262e8b8","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWTFD","TargetGUID":"4d2340a5-3042-3431-3030-304a57544644","Type":"sas"},{"Id":"MB012000JWTFC","TargetGUID":"4d2340a5-3042-3231-3030-304a57544643","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T04:04:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。 このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。 </li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB014000JWTFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWTFC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"74601a1ea2da4cf7b34522876cd96046"}]},{"ProductId":"a88170da558d4ca79c0a5aa7982152c5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19899653","DateModified":"2025-03-06T12:40:23","FileList":["/CP065964_BUILD_6.data","/CP065964.vmexe64","/CP065964.vmfile","/CP065964_VMw.zip","/CP065964.xml","/payload.json","/CP065964_VMw.zip/index.xml","/CP065964_VMw.zip/vendor-index.xml","/CP065964_VMw.zip/metadata.zip","/CP065964_VMw.zip/vib20/CP065964/HPE_bootbank_CP065964_HPG1.6-8.0.0.20613240.vib","/CP065964_VMw.zip/metadata.zip/vendor-index.xml","/CP065964_VMw.zip/metadata.zip/vmware.xml","/CP065964_VMw.zip/metadata.zip/vibs/CP065964-4772671323534759563.xml","/CP065964_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065964_HPG1.6-8.0.0.20613240.xml"],"MD5Sum":"ce46d261fa05e83eca120b09b006fbd6","Name":"CP065964.zip","Release":"2025-03-06T12:39:35","Revision":"E","SHA1Sum":"79eda59b2ca24878d51e49c9a86b71149198a8b8","SHA256Sum":"762429956e3644404daa1e6333e61b33d7d20b8af87cacd92a86a976bef9e84e","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065964","Version":"HPG1.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:21:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ea988c1bdb0e488ea2464583c089174e"}]},{"ProductId":"6d1e58e8f89340958bf7818046e9b7c7","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2343696","DateModified":"2025-03-25T06:40:19","FileList":["cp066448.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"0e2ee04dfb05ef0ab0491d136e5092df","Name":"cp066448.exe","Release":"2025-03-25T06:26:05","Revision":"","SHA1Sum":"d655aad553ec4b8bc949a9803c2287b771e0553a","SHA256Sum":"cb2db4ddce0083f3afca586802d374984dba868980d594041c088d07073206f8","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7f183d5e3e9b4b91b5341e107b63956c"}]},{"ProductId":"17b00802f88a41f591cee6102caaf9d2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;&nbsp; Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;&nbsp; Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4500640","DateModified":"2025-01-10T12:08:20","FileList":["cp065045.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512EDA.rel"],"MD5Sum":"575d5553f51bc725ad829596bd32b466","Name":"cp065045.exe","Release":"2025-01-10T12:03:52","Revision":"D","SHA1Sum":"d652017d04f9f4f86f16d37e95968dd202d26bfd","SHA256Sum":"68f05dd93197b04117e5483641f3218c40797afd5bb220076308c3ebfeec3366","Size":"4MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T10:54:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"27d5e68a43874e2bae8e23cde47408a9"}]},{"ProductId":"6973afa059034a93b5842e17d11d1b46","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssATFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB012000GWDFE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GWDFE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20476328","DateModified":"2025-03-07T08:17:31","FileList":["/CP065936_BUILD_5.data","/CP065936.vmexe64","/CP065936.vmfile","/CP065936_VMw.zip","/CP065936.xml","/payload.json","/CP065936_VMw.zip/index.xml","/CP065936_VMw.zip/vendor-index.xml","/CP065936_VMw.zip/metadata.zip","/CP065936_VMw.zip/vib20/CP065936/HPE_bootbank_CP065936_HPG5.5-1OEM.800.1.0.20613240.vib","/CP065936_VMw.zip/metadata.zip/vendor-index.xml","/CP065936_VMw.zip/metadata.zip/vmware.xml","/CP065936_VMw.zip/metadata.zip/vibs/CP065936-1947059978306613635.xml","/CP065936_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065936_HPG5.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"230f9d42487b7ba18790e8b49dab4bd2","Name":"CP065936.zip","Release":"2025-03-07T08:16:36","Revision":"C","SHA1Sum":"66f1c35d054202e0a368ac5e60b15e6df0825e9e","SHA256Sum":"ec692691bb8d7de091808dbf20426b14952c06b2e0427a7ecbbad49f288f6cd6","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP065936","Version":"HPG5.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042747.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWDFEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000GWDFE","TargetGUID":"4d2340a5-3042-3231-3030-304757444645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:53:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fede14675b304e50949cd7916c7f0ba3"}]},{"ProductId":"91adee7c0766499184ce8d25a925669e","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16802814","DateModified":"2022-07-14T09:25:35","FileList":["IEGen10_0.2.3.0.signed.bin","IEGen10_0.2.3.0.xml","IEGen10_0.2.3.0_B.signed.bin","payload.json"],"MD5Sum":"110d8fc38adb8d242bb703af9f537e4e","Name":"IEGen10_0.2.3.0.fwpkg","Release":"2022-07-14T09:22:01","Revision":"B","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","Size":"16MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2022-08-14T09:18:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>なし</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし        </p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になる可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"40c0e7a8438342b484e5d401d21392eb"}]},{"ProductId":"4bdcb7d3fc5c4d14af793003b89e365b","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33610522","DateModified":"2025-04-18T14:21:16","FileList":["payload.json","U45_3.50_04_17_2025.signed.flash","U45_3.50_04_17_2025.xml"],"MD5Sum":"ed484400c028ebf039212a07f6b1d212","Name":"U45_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"bed15662762994772964e4522177a990e13dc109","SHA256Sum":"e60632253751daac4626c6d14408f3bc9a4f35366221cc0eb3e04ceba3d03593","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"9c66fef2a5e24444810eda416e975afe"}]},{"ProductId":"f22e031456d1410688940c3efe38cf1d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.60 (05/16/2025)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9047880","DateModified":"2025-05-21T01:53:19","FileList":["cp067175.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_3.60_05_16_2025.signed.flash"],"MD5Sum":"ccefbd5a202b455f821c62824eed61c6","Name":"cp067175.exe","Release":"2025-05-21T01:51:36","Revision":"","SHA1Sum":"fe0beee3571c3b458e5364c80f052cf8b90b4105","SHA256Sum":"1e393fc4f90d0a2da32fa6ff7f6f34b95833dd8f49331d5697695ba05f614487","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:38:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"ba9108add0d643d88bd951b946d3ed53"}]},{"ProductId":"8bd617958fd64494b0066602dc57ff65","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064844.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2635144","DateModified":"2025-02-10T07:56:19","FileList":["cp064844.compsig","cp064844.zip","cp065605.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"e7cab34b599bc7ec44aedb7fb540fae1","Name":"cp065605.exe","Release":"2025-02-10T07:54:20","Revision":"B","SHA1Sum":"4842e85708197ff0c22db83d6b9596d9fd2e25bf","SHA256Sum":"6dce7ce78cbebcd1a811aceedd03f52cbe0e89371c9e3d802738b70c22e34a14","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:51:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e22c339103ae403aa80a57006327e9a3"}]},{"ProductId":"0a8a267d13ac4d5588a19d1f0bcc2f5d","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_4030-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.35.4030"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHTアダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.4030</td><td>MT_0000000416</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet専用アダプター</strong></td><td><strong>ファームウェアバージョン</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.4030</td><td>MT_0000000416</td></tr></tbody></table><p> </p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td><td>16.35.4030</td><td>MT_0000000416</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"5335280","DateModified":"2024-09-10T10:32:14","FileList":["16_35_4030-MCX512F-ACH_Ax_Bx.pldm.signed","16_35_4030-MCX512F-ACH_Ax_Bx.pldm.xml","payload.json"],"MD5Sum":"bebb2a18682c364ef1d6525f61fe72ad","Name":"16_35_4030-MCX512F-ACH_Ax_Bx.pldm.fwpkg","Release":"2024-11-13T00:00:00","Revision":"","SHA1Sum":"f89d09bc1eebd8b1d8fa632c1d43d304eb8b1d53","SHA256Sum":"01dff74793c7d26b8d80f0f657df3fb37d9412b9f6846ed56b452a0821c078da","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30116"],"TypeOfChange":"1","Version":"16.35.4030"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動し -> 左側の[ファームウェア&OSソフトウェア]をクリック、 -> [ファームウェアのアップデート]をクリック、 -> [Choose File]をクリックして、サポートされているPLDMファイルを参照し、 -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHTアダプター用Mellanoxファームウェアパッケージ（FWPKG）"},{"Lang":"cn","Value":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-03T10:32:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御の非PFドライバー構成 (SET_HCA_CAP.sw_r_roce_src_udp_portで設定) を無視したときに、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"16.35.4030"},{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御の非PFドライバー構成 (SET_HCA_CAP.sw_r_roce_src_udp_portで設定) を無視したときに、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"16.35.4030"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX512F-ACHT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"42c6e06f00424a398bd9a095db068d19"}]},{"ProductId":"36877a0ed97d40a29cfe6cb469a6e72f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11797952","DateModified":"2025-04-18T11:47:22","FileList":["cp066808.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_3.50_04_17_2025.signed.flash"],"MD5Sum":"1a8dcc09524881b1b7f4dfe91726ceae","Name":"cp066808.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"f99f2822812e48e5abce29172b9154208cbf6344","SHA256Sum":"6c9580261f573a5054cdfda42176c7bfcae605072e8009726539d0e6b0113472","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"22ee112e0b4d453ea9aa6e0e39cc022c"}]},{"ProductId":"cd4b5a9c9ed9405abbc5be7a9f037870","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5, 6 and 7 (iLO 5,6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7451081","DateModified":"2025-07-29T07:03:15","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/101163431a0dde9410ebdb550103741b91996a","./usr/lib/.build-id/00/101163431a0dde9410ebdb550103741b91996a.1","./usr/lib/.build-id/32","./usr/lib/.build-id/32/6e10f2eddaff40e8a9864c55a06e7c3d19793e","./usr/lib/.build-id/32/6e10f2eddaff40e8a9864c55a06e7c3d19793e.1","./usr/lib/.build-id/34","./usr/lib/.build-id/34/1d37eac8148a76a79c9dc7069d0342ac4fc594","./usr/lib/.build-id/34/1d37eac8148a76a79c9dc7069d0342ac4fc594.1","./usr/lib/.build-id/38","./usr/lib/.build-id/38/9956a8b12496568d502a240a11f8d2e4975654","./usr/lib/.build-id/41","./usr/lib/.build-id/41/5fbeb4fead9344ceeebd33e7b079886013943d","./usr/lib/.build-id/41/5fbeb4fead9344ceeebd33e7b079886013943d.1","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/3f71d87e8cbdec67af3507021e320fab6c3815","./usr/lib/.build-id/81","./usr/lib/.build-id/81/4652840663c6aa1d0e55963925402b75bc96e0","./usr/lib/.build-id/81/4652840663c6aa1d0e55963925402b75bc96e0.1","./usr/lib/.build-id/81/bf49f26a7329e6d95cc02b5b56fc712a916221","./usr/lib/.build-id/81/bf49f26a7329e6d95cc02b5b56fc712a916221.1","./usr/lib/.build-id/db","./usr/lib/.build-id/db/126b4bd171ebdde3b46bc1f00d4adbe7a1bbac","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"8b4717beb0576c84b942b284de5e7ddc","Name":"amsd-4.2.0-2061.10.sles15.x86_64.rpm","Release":"2025-07-29T11:58:08","Revision":"","SHA1Sum":"8be881baa22f7651eb5fe6395e70c6418ccf942d","SHA256Sum":"74c0f67de56eadba69fac3a28f4d226f16ede7d4ec43e9967b32b11a34cec5b2","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.2.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"Agentless Management Service (iLO5、iLO6、iLO7) for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"Agentless Management Service (iLO5, iLO6, iLO7) for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T10:05:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.1.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"4.2.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"dbecb0f8fd1e4cee981fe7110f77fcb2"}]},{"ProductId":"eaf211f134ef40ba8eea9bd4163e6e57","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb) to (igb). Now we revert this change from (igb) to (<strong>hp</strong>-igb).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-igb and kmod-igb are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-igb and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-igb-5.14.16-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-igb）から（igb）に変更されました。この変更を（igb）から（<strong>hp</strong>-igb）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-igbとkmod-igbはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-igb-5.14.16-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-igbによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb) to (igb). Now we revert this change from (igb) to (<strong>hp</strong>-igb).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-igb and kmod-igb are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-igb-5.14.16-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-igb and then install the updated RPM.</p>"}],"Files":[{"Bytes":"183123","DateModified":"2025-04-01T09:06:21","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-igb","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/11","./usr/lib/.build-id/11/fa0dda497785258c0077276c01632961339846","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"MD5Sum":"b092d8c132e1fd733fc35f71249c46c9","Name":"kmod-hp-igb-5.18.7-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T08:56:05","Revision":"","SHA1Sum":"ee448d51b12518c7a62d879e41a30d8f5c75f1f3","SHA256Sum":"c91c3ffb415bdb9a9e17d502883013e5f2f194a552fa29f2ff6414676be61aef","Size":"178KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.18.7-1"},{"Bytes":"182981","DateModified":"2025-04-01T09:02:06","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-igb","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/62","./usr/lib/.build-id/62/322372fd08437596efe59e3c4c3ce959cd70df","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"MD5Sum":"5ccdd6dfcb38de620b554d93ceffbb27","Name":"kmod-hp-igb-5.18.7-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T08:56:05","Revision":"","SHA1Sum":"5d10f4275e91ea1b4c6f6d2650b79d44a2e53c8f","SHA256Sum":"0c4f696b05d9e71ce377ec757a8ad84347a7d2815f460ca7cf2704ef2c037912","Size":"178KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.18.7-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel igbドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:11:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、カーネルのコンパイルの問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"5.17.4-1"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"5.18.7-1"}],"SWKeys":[{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7d17f7591d05448c9862cdd80d224da9"}]},{"ProductId":"8adb99f8960b4849ba6664217211b8d2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルにファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; 4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><ul><li>Added support for RHEL10.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li><li>Fixed CA <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00126514en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5379559","DateModified":"2025-05-14T04:42:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/CP066566.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066566.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066566.scexe"],"MD5Sum":"7536477b0411b7f0baa9dfaea20e5d6c","Name":"firmware-hdd-92d876cfea-4ICRHPK3-14.1.x86_64.rpm","Release":"2025-05-14T09:30:44","Revision":"N","SHA1Sum":"7db6ddcd94ee751f1d474c72226eb6d1657ace21","SHA256Sum":"3f75e10bce2d0d480fc8328799064d1c6f2898d998e2883e694c39db40336b3d","Size":"5MB","TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報:</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:07:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e1e201bcb935409388c5a8bdcdd831c1"}]},{"ProductId":"31e3c0de86a045739aadd70ea35e114f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16814308","DateModified":"2025-05-21T02:44:17","FileList":["payload.json","U60_2.40_05_16_2025.signed.flash","U60_2.40_05_16_2025.xml"],"MD5Sum":"415d120d4997f9366576f66e8892d33e","Name":"U60_2.40_05_16_2025.fwpkg","Release":"2025-05-21T02:40:26","Revision":"","SHA1Sum":"c14355642fc1f68c2b47918f162b2d86d2812b48","SHA256Sum":"4e09711089498ae825cee8e25696cab74f37f52069502adf6714cd31a6da2993","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10 Plus サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:30:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"77ad76a0a5624d6083c3d808089ac344"}]},{"ProductId":"8f93dddcb15744aab6bb426d5e84dee8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improve the FW about data mismatch after SPL</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0.</li></ul>"}],"Files":[{"Bytes":"10042137","DateModified":"2025-05-14T05:39:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/CP066571.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066571.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066571.scexe"],"MD5Sum":"48318a6b11479d581c1a1c1713e4a8a5","Name":"firmware-hdd-befd42bd64-HPG3-5.1.x86_64.rpm","Release":"2025-05-14T10:28:14","Revision":"E","SHA1Sum":"396ca0f6ccba5b827abc722c31002e6d5afcaab9","SHA256Sum":"b4e83eec678a497756f581bdfc5fb6c063d8fd02d2cf3904b6f39d8ea63631d2","Size":"9MB","TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:54:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"622cac7b41c94bcf806e30dfba395f5c"}]},{"ProductId":"fcf6b49416e1460393e2103c04483878","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware release provides additional protection against command timeouts.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5157351","DateModified":"2025-05-15T10:43:35","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/CP066514.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066514.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066514.scexe"],"MD5Sum":"3d5b70e50769e237c63f3602305ba6dd","Name":"firmware-hdd-faf39e0ff7-HPD9-9.1.x86_64.rpm","Release":"2025-05-15T15:32:05","Revision":"I","SHA1Sum":"9a8d7cf7ddf5c3f6d201d4fc69f623ab0e7f595c","SHA256Sum":"1b1970a5a83a1ccedd35a85eb210e93643b512251d2106c295c1871bd9e9fa21","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000JWJRQおよびMB006000JWJRPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T03:50:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"26904f3e7b6f43158d547a46e629ac5b"}]},{"ProductId":"cca7377cd12644cab41f5bd7e94cc2bd","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p><strong>HDR / 200GbEケーブル：</strong></p><ul><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6264234","DateModified":"2025-06-16T05:35:14","FileList":["20_43_2566-MCX653105A-ECA_HPE_Ax.pldm.signed","20_43_2566-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"ff9bb32c6661ae9833d895d2c3ba24f9","Name":"20_43_2566-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:33:07","Revision":"","SHA1Sum":"c93d8e7b70e7394d8907dd0d5c7ea317ae83953e","SHA256Sum":"067beaa41f9c0b3701a210cfd67aa1f22a15cc7aae980a59ad8f802870513833","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T05:26:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e1ef68263f2345449fb9be393d817587"}]},{"ProductId":"b24f5415c77d43548ef3f4466312e507","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD9"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JWTFD and MB012000JWTFC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JWTFD and MB012000JWTFC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3313264","DateModified":"2025-01-10T10:43:12","FileList":["cp065032.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG07scHPD9.REL"],"MD5Sum":"516521316cf2ff7b5cd9a8ef38a19191","Name":"cp065032.exe","Release":"2025-01-10T10:37:40","Revision":"B","SHA1Sum":"0fe19396bdfe071b0da726f2a53b890fe8d1a71d","SHA256Sum":"914b2f6a5897358d7ad2e56aa9c1ac517beaf6fa6550ae17ff3b078ca20cb9e4","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JWTFD","TargetGUID":"4d2340a5-3042-3431-3030-304a57544644","Type":"sas"},{"Id":"MB012000JWTFC","TargetGUID":"4d2340a5-3042-3231-3030-304a57544643","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:26:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。 このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。 </li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。 このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。 </li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB014000JWTFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWTFC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"30d8634119a042d5a3ce6f61217d78e4"}]},{"ProductId":"862d36dd920c478ca6dcfdb5f392893a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Optimize thermal&nbsp;maximum continuous operation temperature values</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5884751","DateModified":"2025-05-14T08:01:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/CP066505.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066505.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066505.scexe"],"MD5Sum":"d4f1d777799b1cdb1ff877ef12197612","Name":"firmware-hdd-18e328f036-HPG8-5.1.x86_64.rpm","Release":"2025-05-14T12:49:04","Revision":"E","SHA1Sum":"131af50355deabca8bbe07439caecf5e5b64a5e8","SHA256Sum":"ae26ad2f1d40b5e3911c36787acb81f1661914c0b5d0e63bada37606bb9ce7fe","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T19:52:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0d25c3febd0a4e3993627b8686d1f967"}]},{"ProductId":"ae807ea8d44943a3b60bbbbd54cd062d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"}],"Files":[{"Bytes":"139597","DateModified":"2025-03-05T03:44:06","FileList":["/cp066049.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vib20/igbn/INT_bootbank_igbn_1.12.2.0-1OEM.800.1.0.20613240.vib","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vmware.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vibs/igbn--4585876958502114762.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/bulletins/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4018cf8896862bf89918583c02379f02","Name":"cp066049.zip","Release":"2025-03-05T03:10:51","Revision":"","SHA1Sum":"2594f52a4c2d9e9a0c4af2c3dbe6f37a03477fd1","SHA256Sum":"50e063d2e5a0069ecc45ac61db78d113f1b915f6bbfa4b764ae29a89222494a0","Size":"136KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"igbn","Version":"1.12.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel igbn Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-03T05:14:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Intel-igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"211921c70c1543d6babbf9cbd87892c3"}]},{"ProductId":"81500ed23ae94776ba24fd962d1f8bd1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor."},{"Lang":"ja","Value":"This component installs driverless INFs to identify devices in the processor."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"621616","DateModified":"2024-07-16T09:26:22","FileList":["cp062273.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"MD5Sum":"1f570c5c20a17932d21c5b5d5d87713f","Name":"cp062273.exe","Release":"2024-07-16T09:24:27","Revision":"","SHA1Sum":"788b42b351bbfac4c5c94205a22c9b7d9bd4454c","SHA256Sum":"bb4d17c437e490849ddb0737aa977415c94a573f133402ff983f8b2f862ce83b","Size":"607KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"1","Version":"6.4.8.206"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-15T08:54:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.4.8.206"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b85d3135475a417b921ccef7a253225f"}]},{"ProductId":"7a409aa1e5444a57b8b10f884c98ae5f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"844312","DateModified":"2024-06-13T04:42:22","FileList":["cp061746.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"MD5Sum":"639d9332993167fcd0b0959d025271c2","Name":"cp061746.exe","Release":"2024-06-13T04:26:53","Revision":"","SHA1Sum":"71a8c5d6864e5b57ea0726ec81ed04475add99db","SHA256Sum":"44b7ce0abd18ffc171e00151b0b03b85a221bf338e160d211348d52be7b5eaab","Size":"824KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"TypeOfChange":"1","Version":"2.1.252.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxn Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel vxnドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel vxn Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"211B","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c211b","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-12T07:21:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product updated the copyright information and compatibility with firmware</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は著作権情報とファームウェアの互換性をアップデートしました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product updated the copyright information and compatibility with firmware</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.249.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.1.252.0"}],"SWKeys":[{"Name":"vxn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"61ea1d640329469cbfd27fd265d2dca4"}]},{"ProductId":"b902adf94cea4a0abb9a86aae94c9318","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58505256","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58505452","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58505454","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58505455","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58505255","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5850544e","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58505450","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58505451","Version":"HPK2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK2</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK0</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"6260888","DateModified":"2024-06-25T10:53:19","FileList":["payload.json","SKHynix_PE81X0_KPE81X0AHPK2.HPb","SKHynix_PE81X0_KPE81X0AHPK2.xml"],"MD5Sum":"86491cdfad6f25c2c6eaf885646357af","Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","Release":"2024-06-25T10:50:12","Revision":"","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"TypeOfChange":"1","Version":"HPK2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000800KXPRV","TargetGUID":"4d2340a5-304f-3030-3830-304b58505256","Type":"nvme"},{"Id":"MO001600KXPTR","TargetGUID":"4d2340a5-304f-3130-3630-304b58505452","Type":"nvme"},{"Id":"MO003200KXPTT","TargetGUID":"4d2340a5-304f-3330-3230-304b58505454","Type":"nvme"},{"Id":"MO006400KXPTU","TargetGUID":"4d2340a5-304f-3630-3430-304b58505455","Type":"nvme"},{"Id":"VO000960KXPRU","TargetGUID":"562340a5-304f-3030-3936-304b58505255","Type":"nvme"},{"Id":"VO001920KXPTN","TargetGUID":"562340a5-304f-3130-3932-304b5850544e","Type":"nvme"},{"Id":"VO003840KXPTP","TargetGUID":"562340a5-304f-3330-3834-304b58505450","Type":"nvme"},{"Id":"VO007680KXPTQ","TargetGUID":"562340a5-304f-3730-3638-304b58505451","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-25T10:26:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>&nbsp;This is an initial FW.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p> これは初期FWです。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>&nbsp;This is an initial FW.</p>","Lang":"cn"}],"Version":"HPK0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a maintenance release that contains code improvements for CAP.TO and LED behavior.</li></ul>","Lang":"cn"}],"Version":"HPK2"}],"SWKeys":[{"Name":"MO000800KXPRV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXPTR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPTT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPTU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXPRU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXPTN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXPTP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXPTQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"b3ac2dd86a7d4e9aa3340410288c5fcb"}]},{"ProductId":"d313ecbde1f54151bf42ad357e6b94ad","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18002190","DateModified":"2025-03-24T03:36:35","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/A40_3.50_03_21_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/CP066444.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.50_2025_03_21-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066444.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066444.scexe"],"MD5Sum":"85caf9b2a2ad2243fc52ceccf966aa84","Name":"firmware-system-a40-3.50_2025_03_21-1.1.x86_64.rpm","Release":"2025-03-24T08:28:39","Revision":"","SHA1Sum":"782ea55f90d9de841e1490b33199ddf21e63222e","SHA256Sum":"ab89449c3d3f100aea95d282f88f25ec6a9bce63f7464c230034f8e5b274153f","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプすることにより、hpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL385 Gen10 (A40) サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:28:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4c748ed27834a0d8a9deb80a73921f3"}]},{"ProductId":"d5dd0878f5bc46a1b2bda19d450bbffe","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-3050584d544e","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-3050584d5456","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-3050584d5541","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3050584d544c","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3050584d5452","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-3050584d5454","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-3050584d5455","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO001600PXMTN、MO003200PXMTV、MO006400PXMUA、VO001920PXMTL、VO003840PXMTR、VO007680PXMTT、およびVO015360PXMTU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1573059","DateModified":"2025-03-17T11:11:20","FileList":["Kioxia_PM7_KAPM7ALSHPD3.HPb","Kioxia_PM7_KAPM7ALSHPD3.xml","payload.json"],"MD5Sum":"0304273022b990a9a4c189138ec525d7","Name":"Kioxia_PM7_KAPM7ALSHPD3.fwpkg","Release":"2025-03-17T11:08:37","Revision":"B","SHA1Sum":"e4eab4a2d9778f0dc3dd003814827fa34b2c9bde","SHA256Sum":"7d0c93da2cba8bb367bd249c3ffc0862cccc15aa8122ad6dfd84487404172be1","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-3050584d544e","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3630-3430-3050584d5541","562340a5-304f-3130-3932-3050584d544c","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3531-3336-3050584d5455"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO001600PXMTN、MO003200PXMTV、MO006400PXMUA、VO001920PXMTL、VO003840PXMTR、VO007680PXMTT、およびVO015360PXMTU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO015360PXMTU","TargetGUID":"562340a5-304f-3531-3336-3050584d5455","Type":"sas"},{"Id":"VO007680PXMTT","TargetGUID":"562340a5-304f-3730-3638-3050584d5454","Type":"sas"},{"Id":"VO003840PXMTR","TargetGUID":"562340a5-304f-3330-3834-3050584d5452","Type":"sas"},{"Id":"VO001920PXMTL","TargetGUID":"562340a5-304f-3130-3932-3050584d544c","Type":"sas"},{"Id":"MO006400PXMUA","TargetGUID":"4d2340a5-304f-3630-3430-3050584d5541","Type":"sas"},{"Id":"MO003200PXMTV","TargetGUID":"4d2340a5-304f-3330-3230-3050584d5456","Type":"sas"},{"Id":"MO001600PXMTN","TargetGUID":"4d2340a5-304f-3130-3630-3050584d544e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-03T11:37:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 19-Mar-2025.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 19-Mar-2025.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li><li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us\" id=\"menur2cjc\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00146367en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00146367en_us</a> which will be active on 19-Mar-2025.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MO001600PXMTN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PXMTV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PXMUA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PXMTL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXMTR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXMTT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PXMTU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"fadd667fd8d54d92a41dc3cdbe15df89"}]},{"ProductId":"ffc5db5b28504df99cd08b4bf08ccc7d","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp065000.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.105"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3781264","DateModified":"2025-02-10T07:28:21","FileList":["cp065000.compsig","cp065000.zip","cp065595.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"02489ea54ca8a4ff45383eebd45980b2","Name":"cp065595.exe","Release":"2025-02-10T07:26:44","Revision":"B","SHA1Sum":"e7cfeae5c794149a9796b9eaef3a59ddeed14bd7","SHA256Sum":"5e2991cfcfb2106036cb1b99bfb9c2a5eeb73387665966ba3dff95843b55e824","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.105"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Gen10サーバー向けServer Platform Services(SPS)ファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:06:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3af3ff7548aa4d79aa67bb0e0fa7daaa"}]},{"ProductId":"d00882018d64492aa4a5bc81f394c4dc","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34225456","DateModified":"2025-05-21T12:29:58","FileList":["A46_3.72_05_16_2025.signed.flash","cp067151.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"203961cbb32a68169f8085e96f42315b","Name":"cp067151.exe","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"ebd17b8c2a579bf6904e17c1fbd5e027f2f9efb6","SHA256Sum":"cf67cf2fad8dc80eb998416e95a9e26ad355fd61a28652314c4e4f1938eae602","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5a440780f30643cdb209cecba7cda643"}]},{"ProductId":"ab1694a2c3b34d68b6e9d41c15960bf5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1031144","DateModified":"2024-06-12T10:48:20","FileList":["cp061743.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"c71f3434cedf8170c5f488449e592083","Name":"cp061743.exe","Release":"2024-06-12T10:33:04","Revision":"","SHA1Sum":"7a48dbdc0fad353832273cd32222b6be8a8535f3","SHA256Sum":"1e3b8ff2a6241b25d03f04da7d05e31b077c3737c7fc67c03b533d5d9e7824f3","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2019"},{"Lang":"ja","Value":"Windows Server 2019用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-12T07:18:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new&nbsp;firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the new&nbsp;firmware.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new&nbsp;firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.251.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"accc2576452743ab8b8c3bd27b53b7b4"}]},{"ProductId":"fb9faa50a5034cfe8c3861f763b25770","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064971.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2919000","DateModified":"2025-02-10T08:02:14","FileList":["cp064971.compsig","cp064971.zip","cp065602.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"7f0287f00529696df27b51fbb3cd41e6","Name":"cp065602.exe","Release":"2025-02-10T08:00:24","Revision":"B","SHA1Sum":"24cf0ecfbaaf953ffccab2af8ea7317fa3b20b7e","SHA256Sum":"29d05db943a800c645c2a538dc6ce0ebdc31c04026ac2d45618a48a7a61d85bd","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:45:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f2e37074fdfa4ce991c844227f0f4eae"}]},{"ProductId":"c94eb717d55e4213952a8c5723962404","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11786696","DateModified":"2025-04-18T13:30:13","FileList":["cp066834.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_3.50_04_17_2025.signed.flash"],"MD5Sum":"54625f761254f61f80f369b79023a906","Name":"cp066834.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"9b811ec039656aa2b964d51f5c45b74dd0561e17","SHA256Sum":"1b6288df89607905dc61a18b7fffd589f54f8bc5f8394a2112289a697c875560","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"65a0ebbebcff40cbb4c1a5be9c4ace7c"}]},{"ProductId":"e94dfd89626f4fc992d59a1c00e08f54","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB006000GWJRRおよびMB008000GWJRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"3274800","DateModified":"2025-01-10T10:13:20","FileList":["cp065034.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06ACHPG6.REL"],"MD5Sum":"22050342db0e98f587e7f02f15c36e18","Name":"cp065034.exe","Release":"2025-01-10T10:07:47","Revision":"D","SHA1Sum":"c267d3261465f022a1cfec087885c5bc21532b49","SHA256Sum":"6b68d15b80c3b2a1aaeb6ccd5f26d165c668746ef536a5d1ce327e3f8fd1697b","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:32:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"17a9fe4ec86a42e0a69fddf1bc1783a3"}]},{"ProductId":"ce9f91a90e53444d84d0e7a4367d6fd4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 8.0"},{"Lang":"ja","Value":"このコンポーネントパッケージには、VMware vSphere 8.0で動作するHPE Intel icen Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"}],"Files":[{"Bytes":"724575","DateModified":"2025-04-01T06:37:11","FileList":["/cp064886.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/vendor-index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/vib20/icen/INT_bootbank_icen_1.15.4.0-1OEM.800.1.0.20613240.vib","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vendor-index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vmware.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vibs/icen-1474514971385702191.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/bulletins/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"dc7f04036e3b0d1edb2d152f858ab275","Name":"cp064886.zip","Release":"2025-04-01T06:36:59","Revision":"","SHA1Sum":"07b6e4cf0239940a709274c7d7141ed79dea8c84","SHA256Sum":"8dbc7212453e16a9ad2f283d285674001e42e79d7797d6892d6418affd338673","Size":"707KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"icen","Version":"1.15.4.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icen Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"Intel icenドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"Intel icen Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:19:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Intel-icen:1.15.4.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:1.15.4.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"267c88992ae24d528bc292e1a24614c3"}]},{"ProductId":"02a1f5d0f0e244c0b4c2ace636d0f60b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6381445","DateModified":"2025-05-14T08:39:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/CP066563.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066563.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066563.scexe"],"MD5Sum":"09ab7bce35498441cca9e04f98f10aa4","Name":"firmware-hdd-ca21e169e2-HPG1-13.1.x86_64.rpm","Release":"2025-05-14T13:28:29","Revision":"M","SHA1Sum":"3891b2f5a9fafa2a64f7cc06b0ee34bf9fd6119a","SHA256Sum":"9baf97c98c1962452767b71ad78f11d80f870870d537f786fd12ad63c918c64b","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041494.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000GWKGV ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T19:10:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b23e0a903bf244f1a64152ac37ba8eb9"}]},{"ProductId":"f74d68169f04405fb74a2820e48df6f5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Video"},{"Lang":"ja","Value":"ドライバ - ビデオ"},{"Lang":"cn","Value":"驱动程序 - 视频"}],"Description":[{"Lang":"en","Value":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"Lang":"ja","Value":"このコンポーネントは、Matrox G200eH3ビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1611560","DateModified":"2024-08-28T02:48:18","FileList":["cp062289.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"MD5Sum":"9044970263f6d94b4a1818ec3f122d88","Name":"cp062289.exe","Release":"2024-08-28T02:45:43","Revision":"F","SHA1Sum":"e6ecc31e3e90f6a240df5427aeebca81514b2230","SHA256Sum":"f206862ee8f6038e1f4590f9e7911cdeef4432ed05dc8091ec233f544130ffdf","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.248"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P><P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P><P>Click the \"Install\" button to perform the driver installation.</P>"},{"Lang":"ja","Value":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P><P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P><P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Matrox G200eH3ビデオコントローラードライバーfor Microsoft Windows 64ビット"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"0538","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-0538159000e4","Type":"pci","Ven":"102B"},{"Dev":"0538","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-05381590027f","Type":"pci","Ven":"102B"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-17T03:09:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.248"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.248"}],"SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"929e3933ac1c4923801a2e624c30c5ab"}]},{"ProductId":"87b9a1c22150406cbf61d6b300753282","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>&nbsp; Added support for RHEL10.&nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>&nbsp; Added support for RHEL10.&nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improvement in mixed READ/WRITE performance, which was causing a field issue at an HPE customer -&nbsp;Improve random mix performance in TL=2048k and 512k</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5134956","DateModified":"2025-05-15T10:30:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/CP066599.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066599.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066599.scexe"],"MD5Sum":"e9638e98e732949e9b670e5b234a52ca","Name":"firmware-hdd-c993b31232-HPG6-6.1.x86_64.rpm","Release":"2025-05-15T15:19:07","Revision":"F","SHA1Sum":"59c81277ece739febcddc2127a18ec19427bffff","SHA256Sum":"610f57288879127c45b434555aca9b0e9b3822dee7e4891afaf3fb6d95de6571","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP041676.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T18:26:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"71b30ddb8a744382b3412132d4df4518"}]},{"ProductId":"d09d3bc174174ab69b229c1370a5ce48","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3252920","DateModified":"2025-01-10T10:45:17","FileList":["cp065026.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEn0HPD5.REL"],"MD5Sum":"24f84663b4660306605d5b0e315e8c24","Name":"cp065026.exe","Release":"2025-01-10T10:40:29","Revision":"E","SHA1Sum":"e34faaf7b09a6f563aeb0a1a838257e3e97ae110","SHA256Sum":"87b9efaa118053dc2d541200311f0e3552cf01105f5bc06b4a9d540b6ff6b404","Size":"3MB","TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:13:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Sever 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Sever 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bc236833822b4c6ba01e8efacf99b583"}]},{"ProductId":"4fd1e8e4a27347cd8d83d1e63d9eb38e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:&nbsp; &nbsp;&nbsp;</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:&nbsp; &nbsp;&nbsp;</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4538344","DateModified":"2025-01-11T11:16:16","FileList":["cp065090.xml","cpqsetup.exe","HVLAeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"91bba410f07e8c5a01974ce37fbc7327","Name":"cp065090.exe","Release":"2025-01-11T11:11:35","Revision":"J","SHA1Sum":"5912612ee4acde358deb4a3386a75b5409fc19b3","SHA256Sum":"aab54cbc56113df7e57ac2f139e9a4c423fcde8134e6f1668f8c4a8a9a851ad8","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000GWKGRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T11:05:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c1f741e6a2dc474395fc0f73b2d0d8e5"}]},{"ProductId":"d473378e1f2847f48383c6be4c105511","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0 and ESXi 9.0"},{"Lang":"ja","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0およびESXi 9.0"},{"Lang":"cn","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0 and ESXi 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"6003744","DateModified":"2025-07-21T15:55:29","FileList":["/cp067424.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip","/sutComponent_800.6.2.0.8-0-signed_component.zip/index.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/vendor-index.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip","/sutComponent_800.6.2.0.8-0-signed_component.zip/vib20/sut/HPE_bootbank_sut_800.6.2.0.8-1OEM.802.0.0.22380479.vib","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip/vendor-index.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip/vmware.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip/vibs/sut-489462034556518779.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip/bulletins/sutComponent_800.6.2.0.8-0.xml","/sutComponent_800.6.2.0.8-0-signed_component.zip/metadata.zip/configSchemas/sut-800.6.2.0.8-1OEM.802.0.0.22380479-schema.json"],"MD5Sum":"0f05c0bbf07d000e3778151b8ea66dfb","Name":"cp067424.zip","Release":"2025-07-21T15:54:51","Revision":"","SHA1Sum":"cb2f71c1eff03bb409d9ed96230d3fec02ffa3d5","SHA256Sum":"9f928899c6bf0728befc02d486c43817e3f8e3dff7f944ebbdf5172431f32e67","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"TypeOfChange":"1","Version":"2025.07.00","VibList":[{"Name":"sut","Version":"800.6.2.0.8-1OEM.802.0.0.22380479"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":150,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li><li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li><li>Enter the iLO credentials (root or administrator username and password).</li><li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li></ol><p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p><p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&amp;docLocale=en_US&amp;page=index.html\">SUM User Guide</a></p><p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the component bundle.</li><li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiant (SPP)からHPE Smart Update Manager（SUM）を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p><ol><li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li><li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/packages</em>ディレクトリにコピーします。</li><li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li>ディレクトリを<em>/packages</em>に変更し、./smartupdate.batまたは./smartupdateを実行します。</li><li>「次へ」ボタンを選択します。</li><li>「シングルターゲットの追加」をクリックします。</li><li>アップデート対象のESXiホストのiLOのIPまたはDNSアドレスを入力します。</li><li>iLO認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li><li>Smart Update Managerの手順に従って、コンポーネントのアップデートを完了します。</li></ol><p>この方法は、このコンポーネントがすでにESXiホストにインストールされていて、自動モードで実行されている場合に機能します。</p><p>『<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&docLocale=en_US&page=index.html\">SUMユーザーガイド</a>』でiLO 5によるサーバーのアップデートを参照してください。</p><p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>コンポーネントバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>コンポーネントバンドルをインストールするには、\"esxcli software component apply\"コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li><li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li><li>Enter the iLO credentials (root or administrator username and password).</li><li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li></ol><p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p><p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00112955en_us&amp;docLocale=en_US&amp;page=index.html\">SUM User Guide</a></p><p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the component bundle.</li><li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0 and ESXi 9.0"},{"Lang":"ja","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0およびESXi 9.0"},{"Lang":"cn","Value":"Integrated Smart Update Tools 6.2.0 for ESXi 8.0 and ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T05:48:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"2025.05.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>See the <a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes</a> for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"2025.07.00"}],"SWKeys":[{"Name":"sutComponent:800.6.2.0.8-0","SWKeyExpectedPath":"software.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3b6b193512cf468dbcb000e245ef0940"}]},{"ProductId":"d780ef43938c40d3a6628583fe2200f7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This firmware revision improves data integrity and reliability by optimizing adjacent track refresh parameters and management of emergency power loss table structure.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in emergency power loss events.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide some minor performance improvements.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5830693","DateModified":"2025-05-15T10:47:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/CP066517.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/TAMG08acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066517.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066517.scexe"],"MD5Sum":"adb858fb51eca086e54cd5f5bda0c14a","Name":"firmware-hdd-e4f147cdd2-HPG4-5.1.x86_64.rpm","Release":"2025-05-15T15:35:04","Revision":"E","SHA1Sum":"97beb865f8de8febfe6ec55f2f84d46cfde1eb65","SHA256Sum":"62ebaf37df02d95b13cd7044a240609725bf34a94f6040b4836051ececd7660f","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T04:39:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"310a7ad382c14ff1a10b35fec7f90267"}]},{"ProductId":"d026cab87ecf46f4a70676c4643d63f0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFPおよびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5421984","DateModified":"2025-01-10T23:54:18","FileList":["cp064802.xml","cpqsetup.exe","KPE60X1GHPK3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"46ee644a996fdaf84f5a91bb824dd911","Name":"cp064802.exe","Release":"2025-01-10T23:49:24","Revision":"H","SHA1Sum":"31a69e904446017f8fbedbbadc10f12b7ed34c4c","SHA256Sum":"d8d9691fb824bb3646dbda7f0f77d64822b135938a6db84f593d8aa91781f67d","Size":"5MB","TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-17T03:58:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e3c99f383993414c861d07819e41a904"}]},{"ProductId":"b8b6b31789ce4119a48876ba4b89c81f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.60 (05/16/2025)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16815652","DateModified":"2025-05-21T01:57:13","FileList":["payload.json","U48_3.60_05_16_2025.signed.flash","U48_3.60_05_16_2025.xml"],"MD5Sum":"8101e538f65987013a8f9ac32cce44e9","Name":"U48_3.60_05_16_2025.fwpkg","Release":"2025-05-21T01:53:22","Revision":"","SHA1Sum":"c29216e2c796308e9ad9d7583136a254910cb996","SHA256Sum":"a824e1344e6cd27037cc4408706afb260562ce5db24f47ece1b8d82c5deaa487","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - MicroServer Gen10 Plus (U48) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:41:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"9b0521eb852f45d4b097828e97857ae3"}]},{"ProductId":"dab6093d4d7545e892501476a1f6d448","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;</p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p>&nbsp;</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;</p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p>&nbsp;</p><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3634504","DateModified":"2025-01-10T11:40:22","FileList":["cp065052.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCPssssASFD4.rel"],"MD5Sum":"5fe79d571642c98f3c4539e8de42c3ad","Name":"cp065052.exe","Release":"2025-01-10T11:35:48","Revision":"B","SHA1Sum":"c1be791aa8d0dfe0dd3e2162e12c722c88645ac7","SHA256Sum":"3c97ed6a92e041e8d1b0dd7504c8c35f1bcfef3fa2a0ff463a91faab46c78bfb","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:11:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b172fd70d0564d65af3fe4502861fe67"}]},{"ProductId":"da6c398c130f48f9a5a32bd3c9213a90","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"9808924","DateModified":"2025-04-22T08:44:01","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/CP066776.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066776.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066776.scexe"],"MD5Sum":"3e278fc603ad117f88f25ced3841092a","Name":"firmware-hca-mellanox-vpi-connectx4-1.0.18-1.1.x86_64.rpm","Release":"2025-04-22T13:40:06","Revision":"","SHA1Sum":"eb48d4833f245ee44fa5f35959ee37a4568e7f9c","SHA256Sum":"f7c0a3cf55eb037cca5d5e38ae22641f74eb627fa9e8238d8fe73b35f4aba47e","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.18"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64)for HPE Mellanox VPI(EthernetおよびInfinibandモード)ConnectX4デバイス - Linux x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T12:23:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.17"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.18"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"37565247caeb422ab6cd3d6026a49663"}]},{"ProductId":"2ed4fb56e81f45b0b8ae601a61b78e6c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1019433","DateModified":"2025-04-02T07:51:17","FileList":["./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/bnxt_en.ko","./lib/modules/5.14.21-150500.53-default/updates/drivers","./lib/modules/5.14.21-150500.53-default/updates/drivers/infiniband","./lib/modules/5.14.21-150500.53-default/updates/drivers/infiniband/hw","./lib/modules/5.14.21-150500.53-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.21-150500.53-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"MD5Sum":"f9c5d8547ade886183fbcb754a3cac25","Name":"bnxt_en-kmp-default-1.10.3_k5.14.21_150500.53-233.0.152.2.sles15sp5.x86_64.rpm","Release":"2025-04-02T07:40:04","Revision":"","SHA1Sum":"166eb28a759f7a3aae1dac3b1cb8117eeee838f2","SHA256Sum":"ab49621ebf57154e7e3c31a17a70a47840358d2241813a488a2ee8135d92a469","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-233.0.152.2"},{"Bytes":"1109056","DateModified":"2025-04-02T07:55:34","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"MD5Sum":"8a57f4ef313233d70aab80deda74338b","Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-233.0.152.2.sles15sp6.x86_64.rpm","Release":"2025-04-02T07:40:04","Revision":"","SHA1Sum":"0bb2ead3e696401dbbfb6afb3a8cfc959b8b82cf","SHA256Sum":"be6f926908864276aac12d95eaf6795fcf6acb72f7c7943b863907c7a17b62ea","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-233.0.152.2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to update the installation location for nicclilom to the correct path.</li><li>This product enhances functionality by querying DCB settings when the NETDEV_CHANGE event occurs.</li></ul>","Fixes":"<ul><li>This product has fixed the ETS validation issue to prevent traffic class (TC) starvation caused by incorrect bandwidth allocation.</li><li>This product fixes the issue where debugfs qp_info displays the UDP source port value incorrectly.</li><li>This product fixes the issue where the device fails to unregister from PTP during shutdown or suspend.</li><li>This product fixes the issue where IPv6 VXLAN decapsulation was not properly supported.</li><li>This product fixes the issue where out-of-sequence (OOS) packets were being dropped.</li><li>This product fixes the issue where flow priority levels 0&ndash;3 were not handled correctly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating a coredump summary.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、nicclilomのインストール場所を正しいパスにアップデートするように強化されています。</li><li>この製品は、NETDEV_CHANGEイベントが発生したときにDCB設定を照会することで機能を強化します。</li></ul>","Fixes":"<ul><li>この製品では、不正な帯域幅割り当てによるトラフィッククラス(TC)の枯渇を防ぐために、ETS検証の問題を修正しました。</li><li>この製品は、debugfs qp_infoがUDP送信元ポート値を正しく表示しない問題を修正します。</li><li>この製品は、シャットダウンまたはサスペンド中にデバイスがPTPから登録解除できない問題を修正します。</li><li>この製品は、IPv6 VXLANカプセル化解除が適切にサポートされていなかった問題を修正しました。</li><li>この製品は、順序外(OOS)パケットがドロップされる問題を修正します。</li><li>この製品は、フロー優先度レベル0 ～ 3が正しく処理されない問題を修正します。</li><li>この製品は、コアダンプサマリーを生成するときにコアダンプファイルデコーダーがクラッシュする問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to update the installation location for nicclilom to the correct path.</li><li>This product enhances functionality by querying DCB settings when the NETDEV_CHANGE event occurs.</li></ul>","Fixes":"<ul><li>This product has fixed the ETS validation issue to prevent traffic class (TC) starvation caused by incorrect bandwidth allocation.</li><li>This product fixes the issue where debugfs qp_info displays the UDP source port value incorrectly.</li><li>This product fixes the issue where the device fails to unregister from PTP during shutdown or suspend.</li><li>This product fixes the issue where IPv6 VXLAN decapsulation was not properly supported.</li><li>This product fixes the issue where out-of-sequence (OOS) packets were being dropped.</li><li>This product fixes the issue where flow priority levels 0&ndash;3 were not handled correctly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating a coredump summary.</li></ul>","Lang":"cn"}],"Version":"1.10.3-232.0.155.5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.10.3-233.0.152.2"}],"SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3f12803836424e7e9e65fa5698f6421b"}]},{"ProductId":"aacf76bfa7674de086e8a84063eadb98","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"DL20ML30Gen10SPS_05.01.05.005.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2004523","DateModified":"2025-01-17T07:51:16","FileList":["DL20ML30Gen10SPS_05.01.05.005.signed.bin","DL20ML30Gen10SPS_05.01.05.005.xml","payload.json"],"MD5Sum":"158487c45610fa400c9428d7f92746e6","Name":"DL20ML30Gen10SPS_05.01.05.005.fwpkg","Release":"2025-01-17T07:50:23","Revision":"","SHA1Sum":"daf32d9af9ea41959924da474d746638a8bb9315","SHA256Sum":"0ec1bbcc31f8569e818c1e587243de86ea1c491d61469977a2361217a54ccccf","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"0","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-01-18T01:32:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS)ファームウェアには、インテル製品アップデート(IPU)バージョンIPU.2023.3ガイダンスに沿ったアップデートが含まれています。<p><strong>ファームウェアの依存関係：</strong></p>なし        <p><strong>改善点/新しい機能：</strong></p><p>このバージョンは、IPU.2023.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし        ","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.04.913"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"c67032ddacfb4f86a77f18f8bd3756cf"}]},{"ProductId":"b57ffa2f7fe942a89e589fe3043c5ffa","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE 12Gb/s SASエキスパンダーのファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3624336","DateModified":"2025-01-16T14:24:20","FileList":["cp065150.xml","cpqsetup.exe","firmware-Signed-5.15-build-000.bin.fw","payload.json","setup.dll"],"MD5Sum":"a251e06b738d239c4b123a363c525d13","Name":"cp065150.exe","Release":"2025-01-16T14:14:38","Revision":"D","SHA1Sum":"bb9ef80573c09436d1a4553701917489777d545a","SHA256Sum":"b775eb4471406aa601ded4908cf6b8b92e9a648585606583b7dc5b2a755a282d","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant&nbsp;</a>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant&nbsp;</a>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant</a></strong>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"面向 Windows (x64) 的在线 ROM 刷新组件 – 适用于 HPE 智能阵列控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 扩展器固件"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-16T06:54:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Microsoft Windows Server 2025をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<p>Support Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"641cc0733124443380110ad92ce3802a"}]},{"ProductId":"ccd2fccdbff94b0ab75d085d46522784","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.473.14"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.473.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12946119","DateModified":"2025-05-07T02:13:33","FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/CP066300.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/elxflashStandalone-linux-14.4.473.14-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/firmware/B14447314.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/firmware/P14447314.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2025.03.01-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066300.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066300.scexe"],"MD5Sum":"15135a32643d8b625c814fcf67175fe9","Name":"firmware-fc-emulex-2025.03.01-2.1.x86_64.rpm","Release":"2025-05-07T07:00:30","Revision":"b","SHA1Sum":"4a0e5a4a52391cebea46190bd9df5938314c5ebb","SHA256Sum":"1298dbaec1afdd015dbd243c1ed83326d86cf531b9478cde82d9740c593ab6be","Size":"12MB","TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.03.01"}],"Installation":{"Command":"installer","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />&nbsp;<br />&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />&nbsp;<br />&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />&nbsp;<br />&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>"},{"Lang":"ja","Value":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br /> <br /> 1. ファームウェアインストレーションツール：rpm -Uvh <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64ビットシステム）。<br /> <br /> 2. 使用するシステムの適切な場所へcdし、./setupを実行してファームウェアをアップデートします<br /> <br /> ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"},{"Lang":"ja","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:11:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a3e31e1494d746f1b386261abca7444b"}]},{"ProductId":"d1880357890d41959529b109e2a869e4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp;</p><ul><li>&nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5335024","DateModified":"2025-01-10T09:43:13","FileList":["cp065020.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2B3.bin","setup.dll"],"MD5Sum":"609de34f7c4ca0f83ea34882cf3fc977","Name":"cp065020.exe","Release":"2025-01-10T09:39:28","Revision":"C","SHA1Sum":"49d8d9116aaece57f28503b57c48fefd308241b8","SHA256Sum":"87802c708ae194d8f2778af1d1794524ff58e5ec57b09e01a03180381942938a","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB016000JXLBAおよび MB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T08:15:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"783bec52c5a04b30b9cf367984f6aeab"}]},{"ProductId":"7a0e2103ab3d449ea173c873ce94c871","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"cn","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされているドライブのSmartSSD Wear Gauge情報の提供を含む、SmartアレイおよびSmartRAIDコントローラーとサポートされているデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"3647459","DateModified":"2025-04-03T05:45:52","FileList":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"MD5Sum":"d3f58358e17710d92d9bbd2828eb5560","Name":"ssaducli-6.45-8.0.x86_64.rpm","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"26c52377cc51a833fe63eece29da1e55562b095d","SHA256Sum":"17f0640bd89978b17cbdc60a3902a7a597a29b7a01716f9b9aa4bbf6a3ef8aa1","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li><li>古いバージョンのSSAがシステムにインストールされている場合、\"rpm -e ssa\"を使用して最初にそれを削除してください。</li><li>\"rpm -Uvh --oldpackage --replacefiles –replacepkgs <file name>\"を使用してアプリケーションをインストールします。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssaにあり、実行可能ファイル名は/usr/sbinに配置されているssaです。</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:35:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"eaf46305a0f0411ca0438bd239ff502c"}]},{"ProductId":"5ace706167bb418f8ac30077c43e3171","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"7.43"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"7.43"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"7.43"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"7708648","DateModified":"2025-02-06T05:12:13","FileList":["cp062900.xml","cpqsetup.exe","HPE_luxor_7.43.bin.fw","payload.json","setup.dll"],"MD5Sum":"246c0d007f5833d2a1db1dfb6e009e5b","Name":"cp062900.exe","Release":"2025-02-06T05:01:51","Revision":"","SHA1Sum":"f2cd2a12ad0c705e0d884d7e258c1154fb3c3718","SHA256Sum":"ae0924a626fd2a298bf0f8adff474c4d9deca02b81b1485f3390303c382ab897","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"7.43"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-09-22T07:47:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for saving Managed SED master key and reset key in cipher text in controller NVRAM instead of clear text.</li><li>Changed temperature polling period from 1 minute to 5 minutes for HBA mode drives that are in low power state.</li><li>Added support for clearing UREs in unmapped LBA range of fault tolerant logical drives.</li><li>Improved random write and mixed read-write performance.</li><li>Added support for SED encryption configuration through Redfish interface.</li><li>Added support of Redfish Chassis implementation for UBM Backplanes.</li><li>Added Redfish ACTION:<ul><li>Storage.SetEncryptionKey</li></ul></li><li>Added support for Redfish property PATCH:<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>Added support for Redfish Status.Conditions property to resources:<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Added support for Redfish properties:<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS only)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>Added support for PLDM Type5 UBM PIC firmware flashing behind expander.</li></ul>","Fixes":"<ul><li>Fixed an issue where the host experienced BSOD while clearing the controller configuration.</li><li>Fixed controller lockups caused by incorrect address reads and partial RAM initialization for PCIe functions, leading to ECC errors.</li><li>Fixed issues with external storage.</li><li>Fixed issues with the SATA drive.</li><li>Fixed issues with the SED drive.</li><li>Fixed issues with the spare drive.</li><li>Corrected MCTP-related issues.</li><li>Fixed surface scan issues on the RAID 50.</li><li>Fixed issues encountered during heavy I/O operations.</li><li>Fixed volume issues on the failed drive.</li><li>Fixed issues for incorrect Severity reported in Redfish events.</li><li>Fixed issues for incorrect Status reported in Redfish resources.</li><li>Fixed an issue with improper capacity information in Redfish drive Name.</li><li>Fixed an issue where Redfish long running task status is not reported.</li><li>Fixed an issue where DurableNameFormat for RAID volumes are reported as UUID in RDE READ operations, but should be NAA.</li><li>Fixed an issue where failed to take ownership of, or to revert, a SED through Redfish.</li><li>Fixed an issue when a drive hosting a RAID 0 Volume is removed and reinserted, a VolumeOK event is not generated.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>マネージドSEDマスターキーとリセットキーを、クリアテキストではなく暗号化テキストでコントローラーNVRAMに保存するためのサポートが追加されました。</li><li>低電力状態にあるHBAモードドライブの温度ポーリング期間を1分から5分に変更しました。</li><li>フォールトトレラント論理ドライブのマップされていないLBA範囲のUREをクリアするためのサポートが追加されました。</li><li>ランダム書き込みと混合読み取り/書き込みのパフォーマンスが向上しました。</li><li>Redfishインターフェースを介したSED暗号化構成のサポートが追加されました。</li><li>UBMバックプレーンのRedfishシャーシ実装のサポートが追加されました。</li><li>Redfish ACTIONを追加しました：<ul><li>Storage.SetEncryptionKey</li></ul></li><li>RedfishプロパティPATCHのサポートが追加されました：<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>リソースにRedfish Status.Conditionsプロパティのサポートを追加しました：<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Redfishプロパティのサポートが追加されました：<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS のみ)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>エクスパンダーの背後でフラッシュするPLDM Type5 UBM PICファームウェアのサポートが追加されました。</li></ul>","Fixes":"<ul><li>ホストがコントローラーの設定をクリアしている際にブルースクリーンが発生する問題を修正しました。</li><li>不正なアドレス読み取りやPCIe機能のための部分的なRAM初期化が原因で発生するECCエラーによるコントローラーのロックアップを修正しました。</li><li>外部ストレージに関する問題を修正しました。</li><li>SATAドライブに関する問題を修正しました。</li><li>SEDドライブに関する問題を修正しました。</li><li>スペアドライブに関する問題を修正しました。</li><li>MCTP関連の問題を修正しました。</li><li>RAID 50の表面スキャンの問題を修正しました。</li><li>負荷の高いI/O操作中に発生した問題を修正しました。</li><li>故障したドライブのボリュームの問題を修正しました。</li><li>Redfishイベントで報告される重大度が誤っている問題を修正しました。</li><li>Redfishリソースで報告されるステータスが正しくない問題を修正しました。</li><li>Redfishドライブ名の容量情報が不適切である問題を修正しました。</li><li>Redfishの長時間実行タスクのステータスが報告されない問題を修正しました。</li><li>RAIDボリュームのDurableNameFormatがRDE READ操作でUUIDとして報告されるが、NAAであるべきである問題を修正しました。</li><li>Redfish経由でSEDの所有権を取得または元に戻すことができなかった問題を修正しました。</li><li>RAID 0ボリュームをホストしているドライブを取り外して再挿入すると、VolumeOKイベントが生成されない問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for saving Managed SED master key and reset key in cipher text in controller NVRAM instead of clear text.</li><li>Changed temperature polling period from 1 minute to 5 minutes for HBA mode drives that are in low power state.</li><li>Added support for clearing UREs in unmapped LBA range of fault tolerant logical drives.</li><li>Improved random write and mixed read-write performance.</li><li>Added support for SED encryption configuration through Redfish interface.</li><li>Added support of Redfish Chassis implementation for UBM Backplanes.</li><li>Added Redfish ACTION:<ul><li>Storage.SetEncryptionKey</li></ul></li><li>Added support for Redfish property PATCH:<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>Added support for Redfish Status.Conditions property to resources:<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Added support for Redfish properties:<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS only)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>Added support for PLDM Type5 UBM PIC firmware flashing behind expander.</li></ul>","Fixes":"<ul><li>Fixed an issue where the host experienced BSOD while clearing the controller configuration.</li><li>Fixed controller lockups caused by incorrect address reads and partial RAM initialization for PCIe functions, leading to ECC errors.</li><li>Fixed issues with external storage.</li><li>Fixed issues with the SATA drive.</li><li>Fixed issues with the SED drive.</li><li>Fixed issues with the spare drive.</li><li>Corrected MCTP-related issues.</li><li>Fixed surface scan issues on the RAID 50.</li><li>Fixed issues encountered during heavy I/O operations.</li><li>Fixed volume issues on the failed drive.</li><li>Fixed issues for incorrect Severity reported in Redfish events.</li><li>Fixed issues for incorrect Status reported in Redfish resources.</li><li>Fixed an issue with improper capacity information in Redfish drive Name.</li><li>Fixed an issue where Redfish long running task status is not reported.</li><li>Fixed an issue where DurableNameFormat for RAID volumes are reported as UUID in RDE READ operations, but should be NAA.</li><li>Fixed an issue where failed to take ownership of, or to revert, a SED through Redfish.</li><li>Fixed an issue when a drive hosting a RAID 0 Volume is removed and reinserted, a VolumeOK event is not generated.</li></ul>","Lang":"cn"}],"Version":"7.11"},{"ReleaseNotes":[{"Enhancements":"<p>SR 2.9.2 patch 1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>SR 2.9.2 patch 1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>SR 2.9.2 patch 1</p>","Fixes":"","Lang":"cn"}],"Version":"7.43"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a107a6172775450aada829c057565d4e"}]},{"ProductId":"c47b4b11bb744418a62b9ae668fd0ea6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC およびMO001920JWWWV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5132520","DateModified":"2025-05-14T06:10:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/CP066532.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066532.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066532.scexe"],"MD5Sum":"1c5af7d834eb4a1646d3a29a14f45160","Name":"firmware-hdd-9ad359dac1-HPDB-4.1.x86_64.rpm","Release":"2025-05-14T10:58:17","Revision":"D","SHA1Sum":"1ccfcba6b6a27f44ae43eb6db661f73f4bb7a537","SHA256Sum":"abb6cb174b6c343241917e228e73e6d43dcffbf933ab827258d08ba18442a2f1","Size":"4MB","TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040601.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、 MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、 MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:05:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c076e824f52e44158dfd6bdf8dcb2911"}]},{"ProductId":"07a5f3ddb9bd4168818fb38406e49473","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Added support for RHEL10.&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Added support for RHEL10.&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5520430","DateModified":"2025-05-15T10:15:17","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/CP066593.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066593.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066593.scexe"],"MD5Sum":"5ea15e905b327e8652b4ed13446b3efb","Name":"firmware-hdd-ef93133161-HPD4-3.1.x86_64.rpm","Release":"2025-05-15T15:04:09","Revision":"C","SHA1Sum":"71c4c4f099d19b162c83cd9ed6ce0618ab6e0e72","SHA256Sum":"519948707bf3a72d29e538c17473d84385b8dec6ac03c14f0e2741e7641b243b","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"CP040353.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T17:49:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"eb5d85635815487389c7cbf3556450fc"}]},{"ProductId":"8be880867f274999951d42eb0e3b0aa8","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Linux operating systems."},{"Lang":"cn","Value":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Linux operating systems."},{"Lang":"ja","Value":"このパッケージは、LinuxオペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"22574","DateModified":"2025-04-23T10:49:24","FileList":["./opt/hpe/ql_smartsan/ql_ss_enablement","./opt/hpe/ql_smartsan/qlssen.sh","./opt/hpe/ql_smartsan/qlssen.txt","./usr/share/smartupdate/hpe-qlogic-smartsan-enablement-kit/component.xml"],"MD5Sum":"34e58861c1b85feddf2c353cfaff4147","Name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","Release":"2025-04-23T10:46:44","Revision":"r","SHA1Sum":"e51cb714b199e9f60949140b74f72108aacff8ee","SHA256Sum":"c92c07edd7f58f594c8d5008130a856d58a03b2e8f58431cf8495af685d0b430","Size":"22KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd61cbbea"],"TypeOfChange":"0","Version":"3.3-3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p><p style=\"margin-left:40px\">To uninstall the QLogic Smart SAN enablement RPM use the following command:</p><p style=\"margin-left:40px\"># rpm -e hpe-qlogic-smartsan-enablement-&lt;version&gt;.noarch.rpm</p><p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p><p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-qlogic-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p><p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>"},{"Lang":"ja","Value":"<p>SmartSANは64ビット固有のキットです。 このコンポーネントをインストールする前に以前のキットをアンインストールすることをお勧めします。</p><p style=\"margin-left:40px\">QLogic Smart SANイネーブルメントRPMをアンインストールするには、次のコマンドを使用します：</p><p style=\"margin-left:40px\"># rpm -e hpe-qlogic-smartsan-enablement-<version>.noarch.rpm</p><p>これは構成可能コンポーネントです。  Smart SAN機能を有効/無効にするための構成ファイルが必要です。  実行される構成がない場合は、現在のSmart SANステータスが提示され、実行が完了します。  それ以上のアクションは行われません。</p><p> </p><p>構成可能コンポーネントについて詳しくは、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00106063en_us\"><em>Smart Update Managerユーザーガイド</em></a>を参照してください。</p><p> </p><p><strong>HPE Service Pack for ProLiantの外部コンポーネントの実行</strong>:</p><p style=\"margin-left:40px\">1. システム管理者（root）としてログインします。</p><p style=\"margin-left:40px\">2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p style=\"margin-left:40px\">3. インストールするには、プロンプトで以下のコマンドを入力してください：<br />                    # rpm -ivh hpe-qlogic-smartsan-enablement-kit-<version>.x86_64.rpm<br />                    例：# rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p><p style=\"margin-left:40px\">4.  インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />                    Installation complete</p>"},{"Lang":"cn","Value":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p><p style=\"margin-left:40px\">To uninstall the QLogic Smart SAN enablement RPM use the following command:</p><p style=\"margin-left:40px\"># rpm -e hpe-qlogic-smartsan-enablement-&lt;version&gt;.noarch.rpm</p><p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p><p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-qlogic-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p><p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Smart SAN enablement kit for Linux"},{"Lang":"cn","Value":"HPE QLogic Smart SAN enablement kit for Linux"},{"Lang":"ja","Value":"HPE QLogic Smart SAN イネーブルメントキット（Linux）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-23T10:09:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 3.3-3</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"en"},{"Enhancements":"<p>バージョン3.3-3にアップデートしました</p><p>このコンポーネントはFIPSが有効になっています。</p>","Fixes":"<p>このコンポーネントはFIPSが有効になっています。</p>","Lang":"ja"},{"Enhancements":"<p>Updated to version 3.3-3</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"cn"}],"Version":"3.3-3"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 3.3-3</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"en"},{"Enhancements":"<p>バージョン3.3-3にアップデートしました</p><p>このコンポーネントはFIPSが有効になっています。</p>","Fixes":"<p>このコンポーネントはFIPSが有効になっています。</p>","Lang":"ja"},{"Enhancements":"<p>Updated to version 3.3-3</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"cn"}],"Version":"3.3-3"}],"SWKeys":[{"Name":"hpe-qlogic-smartsan-enablement-kit","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c5ec7a8df92342eb922c1ef6133c4f2b"}]},{"ProductId":"2b1131d5128b46ff8528f19d5b030560","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"28910128","DateModified":"2025-03-05T01:46:48","FileList":["/CP064970.vmexe64","/CP064970.vmfile","/CP064970.xml","/CP064970_VMw.zip","/payload.json","/README.txt","/CP064970_VMw.zip/index.xml","/CP064970_VMw.zip/vendor-index.xml","/CP064970_VMw.zip/metadata.zip","/CP064970_VMw.zip/vib20/CP064970/HPE_bootbank_CP064970_1.0.2-1OEM.900.0.24580437.vib","/CP064970_VMw.zip/metadata.zip/vendor-index.xml","/CP064970_VMw.zip/metadata.zip/vmware.xml","/CP064970_VMw.zip/metadata.zip/vibs/CP064970-8647428254991213125.xml","/CP064970_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064970_1.0.2-1OEM.900.0.24580437.xml"],"MD5Sum":"ab1e6649cf5b86108455ab2080731493","Name":"CP064970.zip","Release":"2025-03-05T01:50:15","Revision":"","SHA1Sum":"d87c2a726935ec9eb3055a525d296b4ab04baa71","SHA256Sum":"636f0d9c2b9973b11d3dd89ed7c15df839d05063c5b2dbe8f72aeb66ec15635c","Size":"27MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.0","VibList":[{"Name":"CP064970","Version":"1.0.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for Mellanox Open Ethernet cards"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-08T13:34:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f91adc82d1fb4651be71571419b2d861"}]},{"ProductId":"7ead0459ae26493fa240dac6ad17d606","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 8.0上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"28922994","DateModified":"2024-10-29T09:46:55","FileList":["/CP063122.vmexe64","/CP063122.vmfile","/CP063122.xml","/CP063122_VMw.zip","/payload.json","/README.txt","/CP063122_VMw.zip/index.xml","/CP063122_VMw.zip/vendor-index.xml","/CP063122_VMw.zip/metadata.zip","/CP063122_VMw.zip/vib20/CP063122/HPE_bootbank_CP063122_1.0.2-8.0.0.20613240.vib","/CP063122_VMw.zip/metadata.zip/vendor-index.xml","/CP063122_VMw.zip/metadata.zip/vmware.xml","/CP063122_VMw.zip/metadata.zip/vibs/CP063122--6577144768080150656.xml","/CP063122_VMw.zip/metadata.zip/bulletins/Smart-Component-CP063122_1.0.2-8.0.0.20613240.xml"],"MD5Sum":"c3d0d5edcc43c05ddc16b7a5be0b8feb","Name":"CP063122.zip","Release":"2024-10-29T09:49:48","Revision":"","SHA1Sum":"99d381631d1d34ed2730b0b6a7c6abc2f60d5331","SHA256Sum":"31fa8a4052cfcb158b6d350afe58baa6bfadf474b8ab82315471a134c5a3ae9c","Size":"27MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.5","VibList":[{"Name":"CP063122","Version":"1.0.2-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカード用オンラインファームウェアアップグレードユーティリティ（ESXi 8.0）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-03T09:23:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.3502:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.<br />&nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.<br />&nbsp;</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.3502にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p> </p><p><strong>ファームウェアバージョン14.32.1010には新機能の追加も変更もありません。</strong></p><ul><li>3つの新しいアサートフィルター(ヘルスバッファー、NVlog、FWトレース)が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ(rate_limitに接続し、そのレート制限を共有するレート制限要素)へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。有効にするには、PF_NUM_OF_VF_VALIDをtrueにし、PF_NUM_OF_VFをゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。<br /> </li></ul><p><strong>ファームウェアバージョン16.35.3502には新機能の追加も変更もありません。</strong></p><ul><li>TCP IPv4フローを変更し、ステアリングTIR rx_hash_symmetricフィールドが、SRCフィールドとDST フィールドの両方がゼロに設定されていない場合にのみ有効になるようになりました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアバージョン14.32.1010で修正されました。</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。<br /> </li></ul><p><strong>ファームウェアバージョン16.35.3502には修正が含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.3502:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.<br />&nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.<br />&nbsp;</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"cn"}],"Version":"1.0.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.5"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2be34b80f8064dcfb76b59eb46f0311b"}]},{"ProductId":"5b139cd72d0b4c89818f276c3a1dce8c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problem Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"9889713","DateModified":"2025-05-14T05:43:49","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/CP066572.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/MPK78H5Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066572.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066572.scexe"],"MD5Sum":"71abb366400e5985ce036bdb0ae5b81f","Name":"firmware-hdd-e320db791d-MPK78H5Q-5.1.x86_64.rpm","Release":"2025-05-14T10:29:18","Revision":"E","SHA1Sum":"1d88fae7312cbc4e00ec45c5f037ce7edf3712f3","SHA256Sum":"0096186b00cd5682b22881117fa03e65d088f54519c8d897572a6e06a8d6e14c","Size":"9MB","TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報:</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:55:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c6fba112306145eb968f45929aec2ab9"}]},{"ProductId":"bce1dc60182942cc938b19de857de7fd","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5140408","DateModified":"2025-03-24T06:45:18","FileList":["Config.xml","cp066423.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"MD5Sum":"bc677de03730b0304fa8d765ffaa3e72","Name":"cp066423.exe","Release":"2025-03-24T06:43:48","Revision":"L","SHA1Sum":"b74f20fb7b96dea62c535036e2a028a11f5027c0","SHA256Sum":"2a585dead907cf726e14c39123bef470f2fc4d1dad90be745f0f8740b278912f","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD3600 /tD3700 /tD3610 /tD3710 /v5.04 /iReveille-Release-5.04-build-000.bin /lD3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"Windows (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T05:59:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">リリースノート<u></u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v264144/20-D3000-Gen10RN504L_ED12.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6fc4bd1f0b50483eaf9a14b955730fd4"}]},{"ProductId":"c9a4232d8cb349049f544bcc6d02e97f","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-a_Gen10P_52.32.3-6118_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.32.3-6118"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR416i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7507548","DateModified":"2025-06-16T03:25:13","FileList":["HPE_MR416i-a_Gen10P_52.32.3-6118_A.HPb","HPE_MR416i-a_Gen10P_52.32.3-6118_A.xml","payload.json"],"MD5Sum":"a0376ce2c811ca9f21f498b9bdcc4d81","Name":"HPE_MR416i-a_Gen10P_52.32.3-6118_A.fwpkg","Release":"2025-06-16T03:21:58","Revision":"","SHA1Sum":"00560b13407073971dd20cdf2fcf0eab5b5990b2","SHA256Sum":"f79fa7c89f300c67f12a0b611c60ef622bf49d6c37a8d385760a449e233554eb","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.32.3-6118"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR416i-a Gen10 Plusトライモードコントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and are not applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfishデバイス有効化機能強化: Redfish暗号化のサポートを追加(POST&PATCH）</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">注記: MRコントローラーはSEDのみをサポートします。したがって、Volume[EncryptionTypes]はPOST(作成)またはPATCH(アップデート)中に書き込みできません。それに応じて、次の注釈は入力されません。</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o 注記:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted]は、適格なボリュームに対してオプション「true」を指定してのみ発行できます。MRファームウェアではセキュアボリュームを非セキュアボリュームに変更できないため、オプション 'false' を指定した PATCH Volume[Encrypted] は失敗します。</li><li>POST (作成) 中に、RAIDType=Noneのボリュームを作成する場合、「暗号化」オプションは使用できません。これは、MRが1ステップで安全なJBODを作成することをサポートしていないためです。JBODを作成した後、PATCH Volume [Encrypted = true] を発行して安全なJBODを作成できます。</li><li>ユーザーがEKMへの変更を要求するたびに、UEFIドライバー経由でキーを取得するために再起動が必須になります。</li></ul><ul><li>MR408i-pのサポートを追加</li><li>UBM10バックプレーンのサポートを追加しました</li><li>FWアップデート中に中断が発生した場合、UBMコントローラーがブートローダ状態にあるときに、UBM バックプレーンFWバージョン表示とFWアップデートをサポートします。</li><li>マップ解除可能な論理ドライブ用の NVMe SSDをサポートします。SATA SSDは、マップ解除可能な論理ドライブではサポートされないことに注意してください。</li><li>NANDフラッシュリフレッシュの改善</li></ul><p style=\"margin-left:80px\">o 指定された日数後に「System reset required」というイベントを投稿するアルゴリズムが削除されました。更新は同じ指定された時間後に行われ、新しいイベントが以下のように入力されます。</p><ul><li style=\"margin-left: 80px;\">NANDフラッシュのリフレッシュを開始する前に: 「NAND refresh in progress:changing WB Logical Drives to WT」</li><li style=\"margin-left: 80px;\">NAND フラッシュのリフレッシュが完了したら、「NAND refresh complete:changing WT virtual disks to WB」</li><li style=\"margin-left: 80px;\">上記の動作はMR400コントローラーにのみ適用され、MR200コントローラーには適用されません。</li><li>RAID1整合性チェックイベント文字列の変更</li></ul><p style=\"margin-left:80px\">o イベント文字列が「Consistency Check found inconsistent parity on LD <Ld Id> at strip <Strip Number>」から「Consistency Check found inconsistency on LD <Ld Id> at strip <Strip Number>」に変更されました。</p><ul><li>シャットダウン時に構成されたドライブのスピンダウンを制御するための新しいコントローラープロパティ「Spin Down Drives At Shutdown」をサポートします。</li><li>SCSI NVMe変換レイヤー仕様バージョン1.14のサポート</li></ul>","Fixes":"<ul><li>修正 a00143232en_us: HPE MR Gen11 コントローラー - AMD EPYC 9xx5 2P構成のHPE ProLiant DL365/DL385 Gen11 サーバーでコンポーネント整合性ステータスがサポートされていないと表示される</li><li>修正 a00144054en_us: HPE MR Gen10 PlusおよびGen11ストレージコントローラー - システムが VMware ESXiオペレーティング システムを起動すると、SAS/SATA/NVMe ドライブファームウェアのアップデートが成功しない場合があります</li><li>修正 a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - 大量のI/OがアクティブなときにHPE MRSAに予期しない情報が表示される</li><li>CM7 FIPSドライブがSED対応ドライブとして識別されない問題を修正しました。CM7 FIPSドライブモデル番号: VO001920YXUHU、VO003840YXUHV、VO007680YXUJA、MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VV007680LYJKF、VV015360LYXMT、MV003200LYJKH、MV006400LYJKK。</li><li>無効なセキュリティキーを使用して外部ドライブをインポートすると、5回試行してもコントローラーが無限ループに陥る問題を修正しました。</li><li>PCI BARアップデートの進行中に MCTPトラフィックがあるとコントローラーがアサートする可能性がある問題を修正しました。</li><li>Redfish Drive.CapableSpeedGbsがSAS4ドライブに対して22.5ではなく22と表示される問題を修正しました。</li><li>ReuseTargetIdオプションを使用して同じコマンドで複数の論理ドライブを作成すると、作成される論理ドライブの数が予想よりも少なくなる問題を修正しました。</li><li>複数の論理ドライブ構成で固定キャッシュが生成されないことがある断続的な問題を修正</li><li>ホストのタスク管理によりオフライン ドライブ ファームウェアのダウンロードがタイムアウトしたにもかかわらず、ダウンロード完了イベントが生成されるというまれな問題を修正しました。</li><li>サーバーの起動前にキャッシュオフロードが発生すると、RAID5/50/6/60論理ドライブのパフォーマンスが低下する可能性がある問題を修正しました。</li><li>NVMeドライブでパトロール読み取りを実行しているときにコントローラーに障害が発生し、OCR (オンラインコントローラーリセット) で回復する可能性がある問題を修正しました。</li><li>NVMe JBODドライブの最大書き込み同一長または最大アンマップブロック記述子数が上書きされ、SCSI UNMAPまたはWRITE SAMEコマンドが失敗する問題を修正しました。</li><li>ホストが実行時に PCIe BARを構成すると、PCIeメモリ読み取りのUR(サポートされていない要求) が発生する可能性があるというまれな問題を修正しました。</li><li>0より大きく8より小さいパラメーターリストの長さを使用するSCSI UNMAPコマンドが、SCSIセンス キーの不正な要求とパラメーターリスト内の無効なフィールドの追加センスデータで失敗する問題を修正しました。</li><li>PCI bar初期化がブートメッセージ処理を待機してタイムアウトしたためにコントローラーがアサートされる可能性があるというまれな問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and are not applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"cn"}],"Version":"52.30.3-5917"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"cn"}],"Version":"52.32.3-6118"}],"SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"757ded2e2d3b468a8d987bd4f3ede897"}]},{"ProductId":"aa3d4b3746e2485289f458134b1187cd","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /><br /><strong>改善点/新しい機能：</strong></p><ul><li>最初のリリース</li></ul><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"17579607","DateModified":"2025-03-07T08:34:11","FileList":["/CP064920_BUILD_17.data","/CP064920.vmexe","/CP064920.vmexe64","/CP064920.vmfile","/CP064920_VMw.zip","/CP064920.xml","/payload.json","/CP064920_VMw.zip/index.xml","/CP064920_VMw.zip/vendor-index.xml","/CP064920_VMw.zip/metadata.zip","/CP064920_VMw.zip/vib20/CP064920/HPE_bootbank_CP064920_1.27.17-8.0.0.20613240.vib","/CP064920_VMw.zip/metadata.zip/vendor-index.xml","/CP064920_VMw.zip/metadata.zip/vmware.xml","/CP064920_VMw.zip/metadata.zip/vibs/CP064920--5826758252216142537.xml","/CP064920_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064920_1.27.17-8.0.0.20613240.xml"],"MD5Sum":"e9f01041a6480a5b3f146fff648f59b1","Name":"CP064920.zip","Release":"2025-03-07T08:28:31","Revision":"C","SHA1Sum":"f3c397dc352176d2775da2312117cc0a4f74b513","SHA256Sum":"80483b9383a35bd539adfc944c0debebe2f1dcc62360ac5307cbf0159f2d0c2b","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27","VibList":[{"Name":"CP064920","Version":"1.27.17-8.0.0.20613240"}]}],"Installation":{"Command":"CP064920.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":240,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&nbsp; &nbsp; &nbsp; &lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"17000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-06T03:53:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SHA384でカーネル生成環境をアップデートします</li><li>OSをアップデートします</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support ESXi9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"114f2e8b6d9e4deea39e74ff427c00e2"}]},{"ProductId":"f8437d6127664644832d2cd688d58903","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18191944","DateModified":"2025-03-25T02:47:05","FileList":["A40_3.50_03_21_2025.signed.flash","cp066440.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"97f4e403d5b79c25f306d5fba6981dde","Name":"cp066440.exe","Release":"2025-03-25T02:44:43","Revision":"","SHA1Sum":"7c4ac3fc2fa574d66b23995e76eac1f709c629a7","SHA256Sum":"9e21bd0f900a74a349cd5afb6b609429c45fd55284d724934425fc9f2db20b5d","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL385 Gen10 (A40) サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:20:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"461d8ca301d04ea8894607bd81ab3c74"}]},{"ProductId":"3b6a8a58b8154bb1b3a7b5b4416448b8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4011248","DateModified":"2025-01-10T10:51:15","FileList":["cp065031.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08scHPDC.REL"],"MD5Sum":"4d7242cf253da26ecaed99c7a34fe218","Name":"cp065031.exe","Release":"2025-01-10T10:46:32","Revision":"B","SHA1Sum":"3977d34dd0b7795eddbbe868e940d58000c3b852","SHA256Sum":"925ba4d3ff51ca5980dc6c6a8a7c1697da2c577bd78f30a7e5c3f24a95019a67","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:23:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"10b97c7bf5a34a379206aabbc4ecd9d4"}]},{"ProductId":"05f0508175404d989c50e4f9a4e09a23","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6478734","DateModified":"2025-05-15T01:09:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/CP067246.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/cp051154.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/cp051154.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/cp051155.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/cp051155.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067246.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067246.scexe"],"MD5Sum":"3aa989501eb933f5d5c1a1acb1a8dcd8","Name":"firmware-iegen10-0.2.3.0-7.1.x86_64.rpm","Release":"2025-05-15T06:02:31","Revision":"G","SHA1Sum":"33d67e76aa6fd91c3f62c956f86c33c2fc138c8d","SHA256Sum":"9f58f8eb81879db936c7972e1ef2a8e6d6a43285dbca269e239afe244e9bc711","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p><br />ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p><p> </p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T06:00:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver. 0.2.3.0(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver. 0.2.3.0と同等です。ファームウェアをバージョン0.2.3.0にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になったりする可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver. 0.2.3.0(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver. 0.2.3.0と同等です。ファームウェアをバージョン0.2.3.0にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になったりする可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(F) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4cdbdc30522a43f29cce39e54de01af8"}]},{"ProductId":"a6a815c1e19641d7b77e2e862e63ca3a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_4030-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.35.4030"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><p>&nbsp;</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</td><td>16.35.4030</td><td>MT_0000000241</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><p> </p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet専用アダプター</strong></td><td><strong>ファームウェアバージョン</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE (P10112-B21)</td><td>16.35.4030</td><td>MT_0000000241</td></tr></tbody></table><p> </p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><p>&nbsp;</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</td><td>16.35.4030</td><td>MT_0000000241</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"5640268","DateModified":"2024-09-10T10:05:16","FileList":["16_35_4030-MCX562A-ACA_Ax_Bx.pldm.signed","16_35_4030-MCX562A-ACA_Ax_Bx.pldm.xml","payload.json"],"MD5Sum":"54395b89367cd63d696cf12ea9f89472","Name":"16_35_4030-MCX562A-ACA_Ax_Bx.pldm.fwpkg","Release":"2024-11-13T00:00:00","Revision":"","SHA1Sum":"8a8990141ba8dd24c9619d1549bd63c8e8340ad2","SHA256Sum":"c7da6151fe00cd603c9394c17044f9108b4487335a372b651fdcdf3f42030870","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30052"],"TypeOfChange":"1","Version":"16.35.4030"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動し -> 左側の[ファームウェア&OSソフトウェア]をクリック、 -> [ファームウェアのアップデート]をクリック、 -> [Choose File]をクリックして、サポートされているPLDMファイルを参照し、 -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) for  Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）for  Mellanox MCX562A-ACAI Ethernet 10/25Gb 2ポートSFP28 OCP3アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) for  Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-02T06:33:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御の非PFドライバー構成 (SET_HCA_CAP.sw_r_roce_src_udp_portで設定) を無視したときに、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"16.35.4030"},{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御の非PFドライバー構成 (SET_HCA_CAP.sw_r_roce_src_udp_portで設定) を無視したときに、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic directed at specific destinations. This new capability prevents broken connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"16.35.4030"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX562A-ACAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"99251f5455fc47e08673e58bb29ea710"}]},{"ProductId":"1cadb74f384743de9dfa8d9d6bc9f7b5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"18119791","DateModified":"2025-03-06T12:52:59","FileList":["/CP066013_BUILD_8.data","/CP066013.vmexe64","/CP066013.vmfile","/CP066013_VMw.zip","/CP066013.xml","/payload.json","/CP066013_VMw.zip/index.xml","/CP066013_VMw.zip/vendor-index.xml","/CP066013_VMw.zip/metadata.zip","/CP066013_VMw.zip/vib20/CP066013/HPE_bootbank_CP066013_HPG6.8-1OEM.800.1.0.20613240.vib","/CP066013_VMw.zip/metadata.zip/vendor-index.xml","/CP066013_VMw.zip/metadata.zip/vmware.xml","/CP066013_VMw.zip/metadata.zip/vibs/CP066013-4129019086507507800.xml","/CP066013_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066013_HPG6.8-1OEM.800.1.0.20613240.xml"],"MD5Sum":"78e224992e9c50a6c9997e155400829a","Name":"CP066013.zip","Release":"2025-03-06T12:52:11","Revision":"C","SHA1Sum":"8ec9637ba2c4b2d2a09f2b419b59da21a7aafca0","SHA256Sum":"c2c0c6521c01ce6c24f3d1ef11e3b72e2f12e8bf5cac24c3a85865d6aaa22522","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066013","Version":"HPG6.8-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041677.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWJRT","TargetGUID":"4d2340a5-3042-3830-3030-3047574a5254","Type":"sata"},{"Id":"MB006000GWJRR","TargetGUID":"4d2340a5-3042-3630-3030-3047574a5252","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:41:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d7a555d818942488b362fa21fb30dcf"}]},{"ProductId":"05aa24e5db0c41fc91f79deb60685a31","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3797832","DateModified":"2025-01-10T14:18:18","FileList":["cp065064.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGNSD5.rel","setup.dll"],"MD5Sum":"28ea8393813eec1797cfc59f7de685fa","Name":"cp065064.exe","Release":"2025-01-10T14:14:16","Revision":"E","SHA1Sum":"9f947e08b09fd21cef67011bdfd9c57937a2048f","SHA256Sum":"ce62291d60c790024b44d5e1d2d5b9ea97c8898a59f8f8d9ae824e505b4d40aa","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:12:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6045b6b150344af29ac9c978e3235400"}]},{"ProductId":"ae57ff279aab4e628b9d7923b0985d81","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSSD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3432-3030-304a59455645","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB24000JYEVE"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB24000JYEVE"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB24000JYEVE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Improve random read/write perfomance.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付:<br />     </strong>HPD1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>ランダム読み取り/書き込みパフォーマンスを向上します。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Improve random read/write perfomance.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3767426","DateModified":"2025-02-19T17:34:17","FileList":["payload.json","Seagate_Summit_SUMMITSUSSD1.HPb","Seagate_Summit_SUMMITSUSSD1.xml"],"MD5Sum":"c1403bae13651813db1db37d14670994","Name":"Seagate_Summit_SUMMITSUSSD1.fwpkg","Release":"2025-02-19T17:31:37","Revision":"B","SHA1Sum":"3eeaa05dd62bfe2a0d07371c283ad2ce53930afa","SHA256Sum":"487bfdfa259f8267fb7b638ef1570b46ae3768410d53776db4a6eb7077c721d9","Size":"3MB","TargetGUIDs":["002340a5-424d-3432-3030-304a59455645"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB24000JYEVE"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB24000JYEVE"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB24000JYEVE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB24000JYEVE","TargetGUID":"002340a5-424d-3432-3030-304a59455645","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T19:34:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improve random read/write perfomance.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ランダム読み取り/書き込みパフォーマンスを向上します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improve random read/write perfomance.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"MB24000JYEVE","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0102a46c531c47fabb25126f64d65f3b"}]},{"ProductId":"97b8f64d84c04c1a9c4048cae29b4037","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22256851","DateModified":"2025-03-07T06:43:51","FileList":["/CP065993_BUILD_4.data","/CP065993.vmexe64","/CP065993.vmfile","/CP065993_VMw.zip","/CP065993.xml","/payload.json","/CP065993_VMw.zip/index.xml","/CP065993_VMw.zip/vendor-index.xml","/CP065993_VMw.zip/metadata.zip","/CP065993_VMw.zip/vib20/CP065993/HPE_bootbank_CP065993_HPD3.4-1OEM.800.1.0.20613240.vib","/CP065993_VMw.zip/metadata.zip/vendor-index.xml","/CP065993_VMw.zip/metadata.zip/vmware.xml","/CP065993_VMw.zip/metadata.zip/vibs/CP065993--5394737546929750152.xml","/CP065993_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065993_HPD3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"21d1a5ea703a30c1f156a174533d380f","Name":"CP065993.zip","Release":"2025-03-07T06:43:04","Revision":"C","SHA1Sum":"98d1aafdcbf371db3c3d13550fd008bdee4fee5a","SHA256Sum":"2b8d53a2965e857b934eab7d2ec8126f5a8094b3764d8c2b4cd064d0a304340f","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065993","Version":"HPD3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000JXLBAおよびMB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:10:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2c7206dd3d23401086d8b25ae4891eaa"}]},{"ProductId":"8e3928e62813480eab785be8f1d93fd8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"Lang":"ja","Value":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18125941","DateModified":"2025-03-06T12:26:13","FileList":["/CP066012_BUILD_13.data","/CP066012.vmexe64","/CP066012.vmfile","/CP066012_VMw.zip","/CP066012.xml","/payload.json","/CP066012_VMw.zip/index.xml","/CP066012_VMw.zip/vendor-index.xml","/CP066012_VMw.zip/metadata.zip","/CP066012_VMw.zip/vib20/CP066012/HPE_bootbank_CP066012_HPD4.13-8.0.0.20613240.vib","/CP066012_VMw.zip/metadata.zip/vendor-index.xml","/CP066012_VMw.zip/metadata.zip/vmware.xml","/CP066012_VMw.zip/metadata.zip/vibs/CP066012--366548957544949651.xml","/CP066012_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066012_HPD4.13-8.0.0.20613240.xml"],"MD5Sum":"ef141b57374701860c1c6fafccaeb7f4","Name":"CP066012.zip","Release":"2025-03-06T12:25:28","Revision":"M","SHA1Sum":"1c9b666a586bcdc2b1eea8ad022c6a9f31e7d7c1","SHA256Sum":"792cf4c6e23bdf22865dbe62567146150e12f7ded0b80cadab2bd36db5cd273c","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP066012","Version":"HPD4.13-8.0.0.20613240"}]}],"Installation":{"Command":"CP040513.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFDSL and MB4000JFDSN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB2000JFDSL","TargetGUID":"002340a5-4d00-3242-3030-304a4644534c","Type":"sas"},{"Id":"MB4000JFDSN","TargetGUID":"002340a5-4d00-3442-3030-304a4644534e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:32:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB2000JFDSL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB4000JFDSN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f7dcdb37be9743b1b240ff29655c8201"}]},{"ProductId":"8ae644bee0c14cc0b7aad5521f061ad1","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Windows Server 2022, and Windows Server 2025 Only."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2022およびWindows Server 2025のみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7152512","DateModified":"2025-04-07T07:08:14","FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp066650.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"302a96e515f90b80c22ef537674b288e","Name":"cp066650.exe","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"b11cf95b808b568a64f9d7645c6bb25155cc70f5","SHA256Sum":"df5d5eb92691b62b5322aa0d355329d4fc834c704ff126af6642c4698b604369","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"5.4.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 1Gb Driver is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","SWKey":"b57nd60a.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Windows Server x64 Editions for HPE ProLiant Gen10 server series Only"},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Windows Server x64 Editions（HPE ProLiant Gen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:35:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"}],"SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"b2a8f95ae4144eb3a87ab38ecf2bb22d"}]},{"ProductId":"a77901ff235c43f18df58616eefb654e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Eth 10/25Gb 2p Sec Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f159003fe","Version":"26.45.1020"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor HPE向けNVIDIA Ethernet 10/25Gb 2ポートSFP28 NVMe-oF暗号アダプター"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE</td><td>26.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7172243","DateModified":"2025-07-24T04:54:16","FileList":["26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","26_45_1020-S2A69-63001_Ax_header.pldm.xml","payload.json"],"MD5Sum":"dfe472c139cf306152a43e16c6462fd0","Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","Release":"2025-07-24T04:52:14","Revision":"","SHA1Sum":"193a4343f5779fda246fd1d743eb567b8987a10e","SHA256Sum":"979b65d9f162dafbd4025fedc8f3625cc10a9bf73abe8225f1a17690d6a8cf1a","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"TypeOfChange":"1","Version":"26.45.1020"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ (FWPKG) for HPE向けNVIDIA Ethernet 10/25Gb 2ポートSFP28 NVMe-oF暗号アダプター"},{"Lang":"cn","Value":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101F","SubDev":"03FE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f159003fe","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-30T05:15:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.43.1014にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.45.1020</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.45.1020にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.45.1020</p>","Fixes":"","Lang":"cn"}],"Version":"26.45.1020"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_PA_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"e2fbadb5ead3419e9adfd4a63f824341"},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE NV60100M 100Gb 2p Strg Offload Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d1590037d","Version":"22.45.1020"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor HPE向けNVIDIA Ethernet 100Gb 2ポートNVMe-oFオフロードアダプター"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE</td><td>22.45.1020</td><td>HPE0000000062</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7728938","DateModified":"2025-06-30T06:11:22","FileList":["22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","22_45_1020-R8M41-63001_Ax_header.pldm.xml","payload.json"],"MD5Sum":"f40e268156b69aebda0a4da1be91248a","Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","Release":"2025-06-30T06:08:44","Revision":"","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"TypeOfChange":"1","Version":"22.45.1020"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c04774995#N10048\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\"><strong>USB Key Creator Utility</strong></a>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ (FWPKG) for HPE向けHPE NVIDIA Ethernet 100Gb 2ポートNVMe-oFオフロードアダプター"},{"Lang":"cn","Value":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"037D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d1590037d","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-30T05:23:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン26.43.1014にアップグレードされました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;26.43.1014</p>","Fixes":"","Lang":"cn"}],"Version":"26.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Upgraded to version&nbsp;22.45.1020</p>","Fixes":"","Lang":"cn"}],"Version":"22.45.1020"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7319fd82a07c4804b3f42bdb8e099c29"}]},{"ProductId":"8ebc8805a4344ec4a24a5c7109c6e07f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"7661952","DateModified":"2025-01-11T09:14:16","FileList":["cp065061.xml","cpqsetup.exe","K503HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"bda732183fb942ceffc56b6dcbe54c93","Name":"cp065061.exe","Release":"2025-01-11T09:10:30","Revision":"C","SHA1Sum":"dd61ef385d9c371c10dd00197b4e524fe263c5fc","SHA256Sum":"31bf1754a50ac3bbad71c047e55b85a0519c2bc1b4b58cc20db80565058810dc","Size":"7MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:57:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ce5e8120b98f46689afdf5157ada423c"}]},{"ProductId":"5829ee37bc994558baa6a98dd52b6154","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD8"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD8"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD8"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD8"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20258592","DateModified":"2025-03-06T07:10:52","FileList":["/CP065996_BUILD_2.data","/CP065996.vmexe64","/CP065996.vmfile","/CP065996_VMw.zip","/CP065996.xml","/payload.json","/CP065996_VMw.zip/index.xml","/CP065996_VMw.zip/vendor-index.xml","/CP065996_VMw.zip/metadata.zip","/CP065996_VMw.zip/vib20/CP065996/HPE_bootbank_CP065996_HPD8.2-1OEM.800.1.0.20613240.vib","/CP065996_VMw.zip/metadata.zip/vendor-index.xml","/CP065996_VMw.zip/metadata.zip/vmware.xml","/CP065996_VMw.zip/metadata.zip/vibs/CP065996-1046987780545298029.xml","/CP065996_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065996_HPD8.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"59c1be4b135f9d2d79feb47097992886","Name":"CP065996.zip","Release":"2025-03-06T07:09:59","Revision":"C","SHA1Sum":"b01430b49f636aa2c9f254aea2fc87c1b0fa748a","SHA256Sum":"ab15bd13d4c5662a95ac53f0ac2c6f3747d660082bb26e8ebcf6e502cca144b4","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP065996","Version":"HPD8.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041692.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000600JWJNP、EG001200JWJNQ、EG000600JXLVV、EG001200JXLWA、およびEG001200MXJQUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001200JWJNQ","TargetGUID":"452340a5-3047-3130-3230-304a574a4e51","Type":"sas"},{"Id":"EG000600JWJNP","TargetGUID":"452340a5-3047-3030-3630-304a574a4e50","Type":"sas"},{"Id":"EG001200MXJQU","TargetGUID":"452340a5-3047-3130-3230-304d584a5155","Type":"sas"},{"Id":"EG000600JXLVV","TargetGUID":"452340a5-3047-3030-3630-304a584c5656","Type":"sas"},{"Id":"EG001200JXLWA","TargetGUID":"452340a5-3047-3130-3230-304a584c5741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:29:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"025ff32032524897b703ad63972d6a09"}]},{"ProductId":"9adece559a5e4fcf8de67cd47aa7d7c7","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505a57534c","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30505a57534e","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30505a575350","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30505a584642","Version":"HPD3"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-30505a584555","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960PZWSL、VO001920PZWSN、VO003840PZWSP、VO007680PZXFB、およびVO015360PZXEU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; It has fix code for V6 Read disturb issue and other issue.<br />&nbsp;&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; It has fix code for V6 Read disturb issue and other issue.<br />&nbsp;&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; It has fix code for V6 Read disturb issue and other issue.<br />&nbsp;&nbsp;&nbsp;&nbsp; For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00136659en_us<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1981648","DateModified":"2025-02-19T16:03:19","FileList":["payload.json","Samsung_PM165X_GPM1653SAMD3.HPb","Samsung_PM165X_GPM1653SAMD3.xml"],"MD5Sum":"4c13d4393cf4a89dafd7703d22ed8ab0","Name":"Samsung_PM165X_GPM1653SAMD3.fwpkg","Release":"2025-02-19T16:01:22","Revision":"B","SHA1Sum":"38ead25b3bb4007ec30f6c19966cf60411bc6bca","SHA256Sum":"47dcbfde9fd400fdedafc60db4b6a8e98cf0c6fde655db611a4184f38a137a17","Size":"1MB","TargetGUIDs":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960PZWSL、VO001920PZWSN、VO003840PZWSP、VO007680PZXFB、およびVO015360PZXEU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO000960PZWSL","TargetGUID":"562340a5-304f-3030-3936-30505a57534c","Type":"sas"},{"Id":"VO001920PZWSN","TargetGUID":"562340a5-304f-3130-3932-30505a57534e","Type":"sas"},{"Id":"VO003840PZWSP","TargetGUID":"562340a5-304f-3330-3834-30505a575350","Type":"sas"},{"Id":"VO007680PZXFB","TargetGUID":"562340a5-304f-3730-3638-30505a584642","Type":"sas"},{"Id":"VO015360PZXEU","TargetGUID":"562340a5-304f-3531-3336-30505a584555","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T13:39:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>It has fix code for V6 Read disturb issue and other issue</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>It has fix code for V6 Read disturb issue and other issue</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>It has fix code for V6 Read disturb issue and other issue</p>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"VO000960PZWSL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PZWSN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PZWSP","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PZXFB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PZXEU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"d03b979005d741c397e716fd188f48dd"}]},{"ProductId":"1b2f6dbb532f4c6ca53c07209cbe6b16","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"ja","Value":"<p>この製品には、以下のドライバーが含まれています。</p><ul><li>qfle3バージョン1.4.51.0</li><li>qcnicバージョン2.0.67.0</li><li>qfle3iバージョン2.1.14.0</li><li>qfle3fバージョン2.1.34.0</li></ul>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"}],"Files":[{"Bytes":"1522712","DateModified":"2024-12-10T08:29:53","FileList":["/cp064345.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"MD5Sum":"c6481811688f848dde4e7262f1788016","Name":"cp064345.zip","Release":"2024-12-10T08:29:31","Revision":"","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","Size":"1MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:04:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product corrects an issue which fix TSO (TCP Segmentation Offload) issue when single segment is larger than pkt length.</li><li>This product corrects an issue which PSOD while freeing DMA during &#39;esxcli qlfastlinq qcc&#39; command execution.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、単一のセグメントがパケット長より大きい場合に発生するTSO (TCP セグメンテーションオフロード)の問題を修正します。</li><li>この製品は、「esxcli qlfastlinq qcc」コマンドの実行中にDMAを解放すると PSODが発生する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product corrects an issue which fix TSO (TCP Segmentation Offload) issue when single segment is larger than pkt length.</li><li>This product corrects an issue which PSOD while freeing DMA during &#39;esxcli qlfastlinq qcc&#39; command execution.</li></ul>","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"efd45025f131446c8a82a2b5fbf98968"}]},{"ProductId":"df6ba3c2e569412ab3999b9575ddb1d8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"19400506","DateModified":"2025-03-06T07:33:30","FileList":["/CP066007_BUILD_3.data","/CP066007.vmexe64","/CP066007.vmfile","/CP066007_VMw.zip","/CP066007.xml","/payload.json","/CP066007_VMw.zip/index.xml","/CP066007_VMw.zip/vendor-index.xml","/CP066007_VMw.zip/metadata.zip","/CP066007_VMw.zip/vib20/CP066007/HPE_bootbank_CP066007_HPG6.3-1OEM.800.1.0.20613240.vib","/CP066007_VMw.zip/metadata.zip/vendor-index.xml","/CP066007_VMw.zip/metadata.zip/vmware.xml","/CP066007_VMw.zip/metadata.zip/vibs/CP066007-2964671944557029632.xml","/CP066007_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066007_HPG6.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0c4557952434c869c0207ac2d9a87f78","Name":"CP066007.zip","Release":"2025-03-06T07:32:46","Revision":"C","SHA1Sum":"9fcf0cb698c6d7a2ed2ea572fbf015a075a59a58","SHA256Sum":"5e444f3f784500015d3688437849f391d7251799e831a01cfaf755051420c532","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066007","Version":"HPG6.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043256.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:06:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b900be4b099045c3a7fa9b0424ade33a"}]},{"ProductId":"7eb6e3adc2094748b6a18ae2e5daf1e0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Windows 64 bit operating systems."},{"Lang":"cn","Value":"该软件包提供的套件，在 Windows 64 位操作系统上的 QLogic 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"Lang":"ja","Value":"このパッケージは、Windows 64ビット オペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1568464","DateModified":"2025-05-07T09:10:16","FileList":["cp066952.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"MD5Sum":"f39754ac1f4b4da82ca763e622bb63f3","Name":"cp066952.exe","Release":"2025-05-07T09:07:14","Revision":"p","SHA1Sum":"06e6f8c85a8020d5c4bdcf13db6d845ca4aa7e45","SHA256Sum":"34e4e09a6d1ac277b45edb9dda5e823a8c3ad7ba1f18be704afc8bbe50a6c582","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"TypeOfChange":"0","Version":"1.0.0.1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>This is a configurable component.&nbsp;It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp;If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp;No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><ul><li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>これは構成可能コンポーネントです。 Smart SAN機能を有効/無効にするための構成ファイルが必要です。 実行される構成がない場合は、現在のSmart SANステータスが提示され、実行が完了します。 それ以上のアクションは行われません。</p><p> </p><p>構成可能コンポーネントについて詳しくは、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00106063en_us\"><em>Smart Update Managerユーザーガイド</em></a>を参照してください。</p><p> </p><p><strong>HPE Service Pack for Proliantの外部コンポーネントの実行</strong>:</p><ul><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始します。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p>This is a configurable component.&nbsp;It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp;If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp;No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><ul><li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"cn","Value":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"ja","Value":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-23T10:25:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン1.0.0.1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン1.0.0.1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.1"}],"SWKeys":[{"Name":"QLSMARTSANVer.exe","SWKeyExpectedPath":"%SystemDrive%\\StorageWorks\\Version"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1d3865cb5ec6429dab8f1264deb31ed0"}]},{"ProductId":"365d207e25654d61b3829f731965d204","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6015118","DateModified":"2025-05-14T07:10:37","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/CP066552.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066552.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066552.scexe"],"MD5Sum":"27c403f15df753ee8885b325b288ff3d","Name":"firmware-hdd-a05f29cef3-HPDD-3.1.x86_64.rpm","Release":"2025-05-14T11:59:05","Revision":"C","SHA1Sum":"e663840d7eeedd6efaf41fbb3a746c743f4c64d3","SHA256Sum":"91cdc047fd5c5195fd042b412a8f6dfad56a0cbbb25af5432e4433c0392f3a69","Size":"5MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"Installation":{"Command":"CP040712.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T14:58:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"900220780b604d868392d1ac449defec"}]},{"ProductId":"e951bbca527f4f9f8a089c23c99574fe","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"849744","DateModified":"2025-01-06T07:43:19","FileList":["cp064930.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"MD5Sum":"c524a5900d759d3f1c5b91def242141b","Name":"cp064930.exe","Release":"2025-01-06T07:28:18","Revision":"B","SHA1Sum":"b215a5e73e62dd0f895587000e15048bc6de573e","SHA256Sum":"2d8ed1ee8886e62e8ee99fce5f2d50fbac3781943ec64fa7429540009814a1fe","Size":"829KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.1.252.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2022"},{"Lang":"ja","Value":"Windows Server 2022用HPE Intel vxsドライバー"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-06T06:01:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、新しいファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.252.0"}],"SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"cd02663ccc924a72a399b86dad8b8d94"}]},{"ProductId":"58e30c6460374d34ab64c2a8547dafe2","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p71_PLDMoMCTP_80020037.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-2CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020037</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>80020037</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>80020037</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524495","DateModified":"2025-04-01T06:31:58","FileList":["HPE_E810_2CQDA2_O_SEC_4p71_PLDMoMCTP_80020037.HPb","HPE_E810_2CQDA2_O_SEC_4p71_PLDMoMCTP_80020037.xml","payload.json"],"MD5Sum":"b3004c1c79eb8adef73cbd27705daeda","Name":"HPE_E810_2CQDA2_O_SEC_4p71_PLDMoMCTP_80020037.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"3683c0d27ecd33eef334125a2ef86a712f3d05e1","SHA256Sum":"e2f66478c6483a362b1399ab64ff529b6755958e07a8af7e3bfb06547baa48e3","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:39:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"8c1c80938d4045c08dce59f0193203cb"}]},{"ProductId":"ae6b2b73e1ee45bc9e25c451f9dd6d2f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4143416","DateModified":"2025-01-10T09:51:20","FileList":["cp065022.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09acHPG4.REL"],"MD5Sum":"dbbc46a9d7fa5c364be2d590633c8ee5","Name":"cp065022.exe","Release":"2025-01-10T09:46:48","Revision":"C","SHA1Sum":"15bc56a61c710442abc4a6f9e653fbc6f75ee5ae","SHA256Sum":"3c24fda4570dd5f632e8e1cd97c81f6203581b7816a433abdd5a02bf90a58747","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVVおよびMB018000GYCLL ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T08:42:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0491985370564855a46c53fc71569de0"}]},{"ProductId":"a96fcafbb6d4411b8c5383684726a0e9","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16814178","DateModified":"2025-05-20T12:25:08","FileList":["payload.json","U61_2.40_05_16_2025.signed.flash","U61_2.40_05_16_2025.xml"],"MD5Sum":"3ffced0279cd37db0e9839cfd05a4402","Name":"U61_2.40_05_16_2025.fwpkg","Release":"2025-05-20T12:21:56","Revision":"","SHA1Sum":"3d574003d0820e3fbdee07edefb52f0afd15a353","SHA256Sum":"91003a6cdc4b1b3cd219a985738ac04a5c4d86fb262c65460f91f8b514821725","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:31:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"c39f2bff73b642e2b52bd6ced12061f2"}]},{"ProductId":"bf6c1988a6474823969dd84808070288","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11790136","DateModified":"2025-04-18T13:48:10","FileList":["cp066840.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_3.50_04_17_2025.signed.flash"],"MD5Sum":"783edcc8cb4fcc25d1699b6d2e6c2f6c","Name":"cp066840.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"e9c081a45c5f91d62d9f32bef761710c30659898","SHA256Sum":"5e65ee17ac76ca08761c1ab3caa935bb2b20e2ae99de4128adba1dc471ea2262","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe&nbsp;to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;</p><p>2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファイルをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 </p><p>2.    計算された値を、HPEサポートセンターのダウンロードページにあるインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの完全性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe&nbsp;to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;</p><p>2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"f3512aa578b34f299641d796d51b7362"}]},{"ProductId":"f66d2f40fe3b49a2ae22ce155e429f5c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an issue in previous version where the Inquiry model number is reported incorrectly for first few seconds after the drive is powered on</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6187181","DateModified":"2025-05-14T08:01:16","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/CP066507.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066507.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066507.scexe"],"MD5Sum":"ae063b5bc8fb33aed974be04863a24c5","Name":"firmware-hdd-ae6b41e855-HPD8-7.1.x86_64.rpm","Release":"2025-05-14T12:49:08","Revision":"G","SHA1Sum":"92f99b3e5ce519c1023894fb8cf6cf59e5e3085a","SHA256Sum":"7d37eafbd0735e386205bee82052dc8053cc1848d53d2dbeddcc965e534e9507","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP043258.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:16:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2c253ad9c23c4bb1b90ac566e1061483"}]},{"ProductId":"c3e42591dc7346b48d6b9ae18a9810a3","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34228232","DateModified":"2025-06-16T07:10:18","FileList":["cp067581.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U50_2.42_06_13_2025.signed.flash"],"MD5Sum":"e999340d290907e28695cec0201c491d","Name":"cp067581.exe","Release":"2025-06-16T07:07:54","Revision":"","SHA1Sum":"3acd895a7b33b5bcbd2cfe3a763b728e8f57aeca","SHA256Sum":"3ded4f502e7c2be1411492753991deedc7204bb9b25845237fe62126fc031265","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:07:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"aa52227feb564647a7928cd6a7ac6372"}]},{"ProductId":"e1ccea24a14a427dabc2aadd846feea9","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"571960","DateModified":"2024-03-19T01:03:14","FileList":["cp060558.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"2850be81dc78f672e10ed0ea3e32eee5","Name":"cp060558.exe","Release":"2024-03-19T01:01:17","Revision":"E","SHA1Sum":"797047c9ef09c7d9531b57f2e79ab181815690a2","SHA256Sum":"85d590e75144f7698c5cbeb9903cdac20abf41dbd601a44fc127fa56425e9122","Size":"558KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and 2019"},{"Lang":"ja","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-04-18T16:18:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added supported_platforms tag</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1f4c9a2df6554218adf6c3f194864d69"}]},{"ProductId":"6114e7f77ac240e69cf280b518ec5e27","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"},{"Lang":"ja","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"6162447","DateModified":"2025-05-14T09:07:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/CP066538.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/WRH620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066538.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066538.scexe"],"MD5Sum":"e875eb3f6751d5eb0d7c7cb7b38d6b69","Name":"firmware-hdd-bfc4af697b-HPG6-13.1.x86_64.rpm","Release":"2025-05-14T13:43:06","Revision":"M","SHA1Sum":"6cfc7c611a735f7fa17bd83791836dd8bfdd01e4","SHA256Sum":"4b22d70da168b31926caf1da3ad06a3237a120f44e2aeaf5f0ab18babc91993c","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP040778.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB001000GWFWK","TargetGUID":"4d2340a5-3042-3130-3030-30475746574b","Type":"sata"},{"Id":"MB002000GWFWL","TargetGUID":"4d2340a5-3042-3230-3030-30475746574c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:29:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWFWK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7623e8263668475faf0b510f095be71d"}]},{"ProductId":"45e734b674094fd09fe52836988b3440","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System"},{"Lang":"ja","Value":"ドライバ - システム"},{"Lang":"cn","Value":"驱动程序 - 系统"}],"Description":[{"Lang":"en","Value":"This component provides drivers for HPE NVDIMM-N devices and HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory) installed on systems running Microsoft Windows Server 2016."},{"Lang":"ja","Value":"このコンポーネントは、Microsoft Windows Server 2016を実行しているシステムにインストールされているHPE NVDIMM-NデバイスおよびHPE Persistent Memoryデバイス(Intel Optane DC Persistent Memoryを搭載)のドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1015800","DateModified":"2024-03-18T15:47:13","FileList":["cp060551.xml","cpqsetup.exe","hpenvmbus.cat","HpeNvmBus.inf","HpeNvmBus.pdb","HpeNVMBus.sys","HpeNvmBusApi.h","HpeNVMdisk0101.cat","HpeNvmDisk0101.inf","HpeNvmDisk0101.pdb","Hpenvmdisk0101.sys","HpeNvmDsm.h","HpeNvmInstaller.dll","install.xml"],"MD5Sum":"75ce9bef5318541d4ac75842f76ab1ff","Name":"cp060551.exe","Release":"2024-03-18T15:45:07","Revision":"E","SHA1Sum":"f454e1451e763ef0ff806ca8a7b39f14d75662a2","SHA256Sum":"6efacf56f29ed72448e670f391fb46a19b86c97cab53b46d4bb7d671614702d8","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"TypeOfChange":"0","Version":"3.0.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Steps to install this Smart Component:</p><ul><li>If a previous version is already installed, it is recommended to first stop all use of the Persistent Memory devices and disks, and uninstall&nbsp;it from the Control Panel, Uninstall a Program.</li><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the Install button to proceed with the installation.</li></ul>"},{"Lang":"ja","Value":"<p>このSmartコンポーネントをインストールする手順：</p><ul><li>以前のバージョンがすでにインストールされている場合は、最初にPersistent Memoryデバイスとディスクの使用をすべて停止し、[コントロールパネル]の[プログラムのアンインストール]からアンインストールすることをお勧めします。</li><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始してください。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE不揮発性メモリドライバーfor Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4096"},"SupportedDevices":[{"Id":"ACPI\\VEN_ACPI&DEV_0012","TargetGUID":"","Type":"pnp"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-04-18T13:52:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated installation time</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>アップデートされたインストール時間</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated installation time</li></ul>","Fixes":"","Lang":"cn"}],"Version":"3.0.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"3.0.2.0"}],"SWKeys":[{"Name":"HpeNvmInstaller.dll","SWKeyExpectedPath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"20015faacfff4d009860a489fb8cfc18"}]},{"ProductId":"7ff6f17e72894f4e8c910355a9fb9992","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 9.0上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>"},{"Lang":"ja","Value":"<p>この製品には、以下のドライバーが含まれています。</p><ul><li>qedfバージョン2.74.1.0</li><li>qedrntvバージョン3.71.62.0</li><li>qedentvバージョン3.71.73.0</li><li>qediバージョン2.74.1.0</li></ul><p><strong>既知の問題</strong>: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul><p><strong>Known issue</strong>: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>"}],"Files":[{"Bytes":"5829683","DateModified":"2025-04-10T07:01:10","FileList":["/cp066737.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.80.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedi-1100237886221730174.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedentv--5062932650923935948.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedrntv--1300904974122159212.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/vibs/qedf--7068176324000061616.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240_24647792.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.410.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"52b4936e6c906e0e6e15727394404f3b","Name":"cp066737.zip","Release":"2025-04-10T07:00:59","Revision":"","SHA1Sum":"77a502a20a040a8fc5fee78454b29b1ab09f5667","SHA256Sum":"d404056f1ddb5d1b7fef5f569b4fbc34b3e74404e1634cf240d7b64fb1b46d81","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.80.0-1OEM.800.1.0.20613240"},{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-10T06:54:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在VMware vSphere 9.0をサポートしています。</p><p>既知の問題: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在VMware vSphere 9.0をサポートしています。</p><p>既知の問題: ドライバーのリセットを引き起こす操作を行うと、EnsNetWorldsのCPU使用率が高くなる可能性があります。次のドライバーリリースで完全なソリューションを提供することを目標とします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports VMware vSphere ESXi&nbsp;9.0.</p><p>Known issue: When any operations that cause the driver reset may result subsequently in high EnsNetWorlds CPU utilization. Target to have full solutoin in next driver release</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.410.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.80.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"891f2ffc824a4cc49041d895d19d7c6d"}]},{"ProductId":"a6c377914cad4568810f0a24fc0faa52","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"26882820","DateModified":"2025-03-06T08:43:09","FileList":["/CP065978_BUILD_6.data","/CP065978.vmexe64","/CP065978.vmfile","/CP065978_VMw.zip","/CP065978.xml","/payload.json","/CP065978_VMw.zip/index.xml","/CP065978_VMw.zip/vendor-index.xml","/CP065978_VMw.zip/metadata.zip","/CP065978_VMw.zip/vib20/CP065978/HPE_bootbank_CP065978_HPG3.6-1OEM.800.1.0.20613240.vib","/CP065978_VMw.zip/metadata.zip/vendor-index.xml","/CP065978_VMw.zip/metadata.zip/vmware.xml","/CP065978_VMw.zip/metadata.zip/vibs/CP065978-6737174474719407004.xml","/CP065978_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065978_HPG3.6-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ebdefb9ff926f12ec38050e85c165f3d","Name":"CP065978.zip","Release":"2025-03-06T08:42:23","Revision":"C","SHA1Sum":"574df1184a8b9e8b5571bb54506c68ba5ff73a02","SHA256Sum":"d9fce4e1bcb13e29f8558436bd33af5ae670cf25cf58f9907a53eb226864f977","Size":"25MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065978","Version":"HPG3.6-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043281.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=service%20pack%20for%20proliant%20spp&amp;t=DriversandSoftware&amp;sort=relevancy&amp;numberOfResults=25\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=service%20pack%20for%20proliant%20spp&amp;t=DriversandSoftware&amp;sort=relevancy&amp;numberOfResults=25\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWXFF、MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK003840GWXFL","TargetGUID":"4d2340a5-304b-3330-3834-30475758464c","Type":"sata"},{"Id":"MK001920GWXFK","TargetGUID":"4d2340a5-304b-3130-3932-30475758464b","Type":"sata"},{"Id":"MK000960GWXFH","TargetGUID":"4d2340a5-304b-3030-3936-304757584648","Type":"sata"},{"Id":"MK000480GWXFF","TargetGUID":"4d2340a5-304b-3030-3438-304757584646","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:15:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"828713c2b35a4640b56377bf5971b97b"}]},{"ProductId":"707f07cb4d404d119f2788d168e17586","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34232472","DateModified":"2025-05-21T12:30:45","FileList":["A43_3.72_05_16_2025.signed.flash","cp067146.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"c03549df078e78ec354f1a6beff55f42","Name":"cp067146.exe","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"63e42204bb18fbdf3d47d2e9766da6fa94912951","SHA256Sum":"60cfe1243cb125dac129996ff8dc17cf825eb8479d84abd7920599771d4183c6","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"5ee48f0aa9284b27ab61f4f628dd67d4"}]},{"ProductId":"0f3487315f10473a903e3c353d754526","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"622104","DateModified":"2024-08-03T07:30:14","FileList":["cp062270.xml","cpqsetup.exe","installer.dll","pnp/","pnp/NULL_HECI.cat","pnp/NULL_HECISystem.inf","pnp/RocketLake.cat","pnp/RocketLakeSystem.inf","pnp/TigerLakePCH-H.cat","pnp/TigerLakePCH-HSystem.inf"],"MD5Sum":"9029eacf1aef90b88658d5476ff41944","Name":"cp062270.exe","Release":"2024-08-03T07:27:41","Revision":"C","SHA1Sum":"a7e0a9c8f2edce2630c28af2ae74c9afca0953fe","SHA256Sum":"178dfcac50ed4aff983e6acddc8cc48aa22a9b62de8b7bbbf4ea719eb2d84e82","Size":"607KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19886.8592"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeon E-23xxプロセッサーの識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-08-15T07:25:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SBOM要件をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.18807.8279"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19886.8592"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"face9ded467b4920bb57a17e35fae531"}]},{"ProductId":"8085229a62d8443d85751340431d38d5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.393.20 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4290872","DateModified":"2025-03-10T12:17:21","FileList":["cp063483.xml","cpqsetup.exe","elxdrvr-fc-14.4.393.20-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"5eba6ae97a4c4460188ed8e714a00032","Name":"cp063483.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"7ffe66a65bfb4347bae0bc3c26adafb1567b3c07","SHA256Sum":"1c306fbbd5e70ff869d0bd219ee93ae9abdb438aac5085cf46f250f0c2c3bbc7","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.393.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>    C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2022</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"30ae2e511d3e4e14ab35fa01b5767023"}]},{"ProductId":"189fb9052e994ac694bd5d6fb410f76a","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for MicroServerv2 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_MicroServerv2GEN10Plus_ME_06.00.03.700.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283474","DateModified":"2025-01-19T02:39:17","FileList":["payload.json","SC_MicroServerv2GEN10Plus_ME_06.00.03.700.signed.bin","SC_MicroServerv2GEN10Plus_ME_06.00.03.700.xml"],"MD5Sum":"df2a0b6d36c2ffb4d3eecd3cf8f9660d","Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.700.fwpkg","Release":"2025-01-19T02:37:34","Revision":"","SHA1Sum":"4fd82156e35ff11016de35d0a0b7e342fe3b6679","SHA256Sum":"4a9f520e617ed534d421d1a07cd1b8dc5d6a0202004ffd92660982e0c613bd2a","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"0","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services (SPS)ファームウェアfor HPE ProLiant MicroServer Gen10 Plus v2サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-09T05:27:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services(SPS)ファームウェアには、Intel製品アップデート(IPU)バージョンIPU.2024.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPSは、システムROM 2.00（02/01/2024）以降と組み合わせる必要があります。<p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU.2024.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.604"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"504921384b134492ad7af4ad9b03abcf"}]},{"ProductId":"7db6f792355b49a58fc4f82d6bbbdd99","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612724","DateModified":"2025-04-18T11:40:21","FileList":["payload.json","U32_3.50_04_17_2025.signed.flash","U32_3.50_04_17_2025.xml"],"MD5Sum":"5d273a192fa726447cda639b74dd9866","Name":"U32_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"ba0f81703cb903b4cc53d6a7a5021a09567ed564","SHA256Sum":"b10f205e0cd9a8a2e0f596e23ded636e9fc986212462e2a7985e33744935cf31","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL360 Gen10（U32）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4d93b2498b974df0829d7f866552c246"}]},{"ProductId":"a32bfc6464f84b51997e9a09f493113b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."},{"Lang":"ja","Value":"HPEのサポートされるファイバーチャネルホストバスアダプタードライバーのサポートに各種ユーティリティを提供します。"},{"Lang":"cn","Value":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"30788","DateModified":"2024-10-24T04:25:54","FileList":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"MD5Sum":"8ddb1a53d3b5fd0d40a6be443d6e8854","Name":"fibreutils-4.2-1_sles.x86_64.rpm","Release":"2024-10-24T04:24:04","Revision":"h","SHA1Sum":"720b2c8232dccea3b2537c535ca097d960601f9d","SHA256Sum":"78250c7d8f7e8ff221672739dc382b1b46590f89514ddaeefdb75074e17135a3","Size":"30KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"TypeOfChange":"0","Version":"4.2-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."},{"Lang":"ja","Value":"fibreutils RPMをダウンロードしました。<BR>RPMをインストール/アップグレードするには、rpm -Uvhコマンドを使用します。"},{"Lang":"cn","Value":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)"},{"Lang":"ja","Value":"Fibreutils for HPE Storageファイバーチャネルホストバスアダプター for Linux - SuSE Linux Enterprise Server(SLES)"},{"Lang":"cn","Value":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-03-14T06:48:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"en"},{"Enhancements":"<p>このパッケージでは、SuSE Linux Enterprise Server（SLES）ディストリビューションのみがサポートされています</p><p>このコンポーネントはFIPSが有効になっています。</p>","Fixes":"<p>このコンポーネントはFIPSが有効になっています。</p>","Lang":"ja"},{"Enhancements":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"cn"}],"Version":"4.2-1"},{"ReleaseNotes":[{"Enhancements":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"cn"}],"Version":"4.2-1"}],"SWKeys":[{"Name":"fibreutils","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d76ea60ae7e648c88a52e39902b4937c"}]},{"ProductId":"139d2679780d42b2a020c2a6176ac11b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD4"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD4"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD4"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD4"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD4"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD4"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD4"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD4"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD4"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD4"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD4"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4014672","DateModified":"2025-01-11T08:46:13","FileList":["cp065078.xml","cpqsetup.exe","KAPM6ALSHPD4.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"531d22648f535a486aa4c94d1835a38b","Name":"cp065078.exe","Release":"2025-01-11T08:41:07","Revision":"B","SHA1Sum":"8cdf90a07c2562e822624e5ead60e84f06cb1a80","SHA256Sum":"0cb38826f09c4bd9db28bb0beb15485b52f9266f87cb92bbf016afbf3dcd00d8","Size":"3MB","TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T05:51:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4c19f0e833784a33b6cba21d152c3408"}]},{"ProductId":"62fc8de385854321919207903df8d568","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5228439","DateModified":"2025-05-24T07:42:32","FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"f14e8faca32a5edc16c2ae1cb173ea5a","Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-1.rhel9u6.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"45e203d4ba02ac5723eee1169313c9079d26dd2c","SHA256Sum":"5e054ea33ef954c4abc1b2916c179f037faf902e3a2cf15cb21d814f81c01865","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.14.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />                   <br />                    # rpm -Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.  インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。  </p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                      # rpm -e kmod-qla2xxx-<version>.<OSupdate>.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Update 6 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Update 6 Serverファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプター"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Update 6 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"34ca4717df694227ae59cb8da7f7cd06"}]},{"ProductId":"10b8cebc40fb4b69b234ff81bd7e1d1f","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064979.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2918920","DateModified":"2025-02-10T05:31:16","FileList":["cp064979.compsig","cp064979.zip","cp065577.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"1afcc81b80c6d3f3bd5384fb05833cd8","Name":"cp065577.exe","Release":"2025-02-10T05:29:27","Revision":"B","SHA1Sum":"c56d552e947e2146bd640b23d5673e5cbf0c26f8","SHA256Sum":"ddd470ad3ec9efeb6cbbaa0103c494379d2de87b275fee20777abcd3c72a5fc3","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &nbsp;&lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T05:26:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f01f7319145545cb8b3a036cdcc75b16"}]},{"ProductId":"228e6aefb0ce46a0a7e230319e326d29","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.9.21 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"cn","Value":"This component contains version 9.4.9.21 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"This component contains version 9.4.9.21 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1743984","DateModified":"2023-11-07T09:08:17","FileList":["cp058499.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"c78ef73ae47ce6762a10f86501140efa","Name":"cp058499.exe","Release":"2023-11-07T09:05:29","Revision":"","SHA1Sum":"1889a2aa4bec830b3617807a3db774be2e8c3557","SHA256Sum":"0860fa48e3bd8e95230763ade8055811dba14970c3f367a762117028e969b7a7","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.9.21"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-10-08T10:25:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.8.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.8.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.8.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.8.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.9.21</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.9.21</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.9.21</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.9.21"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5b37c95077cd4ec283667430951de6c1"}]},{"ProductId":"51c52bf006bd4c60b09797563ff886bf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"Lang":"cn","Value":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. SSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"Lang":"ja","Value":"Smart Storage Administrator CLI（SSACLI）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。SSASCRIPTING - スクリプトは、オフラインまたはオンライン環境で実行することができます。SSAスクリプティングアプリケーションは、2つのスクリプティングモード - CaptureおよびInputを持っています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"13158723","DateModified":"2025-04-03T05:41:47","FileList":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.45-8.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"MD5Sum":"0e2e3bb1bcff025a04e6b834f6a342de","Name":"ssacli-6.45-8.0.x86_64.rpm","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"75f36fd3f7d977dbdad85acdbb03a14e558cfaea","SHA256Sum":"488347441a8b6533d7f1ca51f5ff481868336bf0d23fb76a46136540043d4797","Size":"12MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li><li>古いバージョンのSSAがシステムにインストールされている場合、\"rpm -e ssa\"を使用して最初にそれを削除してください。</li><li>\"rpm -Uvh --oldpackage --replacefiles –replacepkgs <file name>\"を使用してアプリケーションをインストールします。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssaにあり、実行可能ファイル名は/usr/sbinに配置されているssaです。</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI for Linux 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:33:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d7db6433534b4431af0282776d796e91"}]},{"ProductId":"b94490ecb4854ca6989ed2491e061c4b","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>Support FIPS enable mode.</p><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：<br />     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの依存関係:</strong><br />     なし<br /><br /><strong>機能強化/新しい機能：</strong></p><p>FIPS有効化モードをサポートします。</p><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><p>Support FIPS enable mode.</p><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5065890","DateModified":"2025-05-14T06:44:28","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/CP066641.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066641.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066641.scexe"],"MD5Sum":"82b1c4d3aefb4ff656812ecd89672d79","Name":"firmware-smartarray-7b5e8400dd-1.27-5.1.x86_64.rpm","Release":"2025-05-14T11:28:30","Revision":"E","SHA1Sum":"7da169abaf81d099ac8e5346fd2c8a82ef7f97d9","SHA256Sum":"c086f0154b286ae3c1fbc3f77a583cdfcc6e4dee25dcc6c72312bd1455e53cdb","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"Installation":{"Command":"CP066641.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-02T02:23:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"21ceab93a88b4ed6bedc7237f1e7b689"}]},{"ProductId":"001e7fbaf67f420ebcb746aae6b4aee2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ<br /><br /><strong>リリースバージョンおよび/または日付：</strong><br />      HPD5<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      HPD4<br /><br /><strong>前のファームウェアバージョン：</strong><br />      HPD4<br /><br /><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：<br />      </strong>なし</p>"}],"Files":[{"Bytes":"18458926","DateModified":"2025-03-07T06:58:26","FileList":["/CP065943_BUILD_1.data","/CP065943.vmexe64","/CP065943.vmfile","/CP065943_VMw.zip","/CP065943.xml","/payload.json","/CP065943_VMw.zip/index.xml","/CP065943_VMw.zip/metadata.zip","/CP065943_VMw.zip/vendor-index.xml","/CP065943_VMw.zip/vib20/CP065943/HPE_bootbank_CP065943_HPD5.1-1OEM.900.0.24580437.vib","/CP065943_VMw.zip/metadata.zip/vendor-index.xml","/CP065943_VMw.zip/metadata.zip/vmware.xml","/CP065943_VMw.zip/metadata.zip/vibs/CP065943--8168030897915548776.xml","/CP065943_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065943_HPD5.1-1OEM.900.0.24580437.xml"],"MD5Sum":"0e127e4bb6a79b62339a4382c15fea01","Name":"CP065943.zip","Release":"2025-03-07T06:57:37","Revision":"C","SHA1Sum":"d9877083724fa72dfbcc2de53637b48694d3ecee","SHA256Sum":"d9104e809dc5c165946f213338a5350e30e328b6579efce26e87a2e02cbd0888","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065943","Version":"HPD5.1-1OEM.900.0.24580437"}]}],"Installation":{"Command":"CP040556.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on 7.0/8.0/9,0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on 7.0/8.0/9,0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:26:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"40e0ce11db3743dc8166e4a30a532fbc"}]},{"ProductId":"e9a45a84fc5a4ae9bee13ee0419530ca","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34033763","DateModified":"2025-06-16T03:31:57","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/CP067584.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/U47_2.42_06_13_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.42_2025_06_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067584.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067584.scexe"],"MD5Sum":"fbc0b9091cabaa9aa90fd306b06ccb8b","Name":"firmware-system-u47-2.42_2025_06_13-1.1.x86_64.rpm","Release":"2025-06-16T08:21:36","Revision":"","SHA1Sum":"fba5624571529edd6c3c1b312ce182d88b97afd4","SHA256Sum":"8166a4d98786bb52d5a9bc3f0efb9dba3e6ebcc8ddde87a78c764c5eb94eb3a5","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:11:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"24ac1d0af5734096a1a6c252a29b7919"}]},{"ProductId":"e760dc1509734b53830053c8a8b00097","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"767898","DateModified":"2025-05-24T09:14:31","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"0c5d310a172c2dcb9f5d1785909c03ac","Name":"kmod-elx-lpfc-14.4.473.24-1.rhel9u5.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"d27c0f68436ce3b62122350c764112e90c7bfe01","SHA256Sum":"24d80298d3f13bc24e88cd57aaf85a8f1e347505dcb82ee69a3e66a52d0858a0","Size":"749KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.473.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1. システム管理者 (root) としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />                    例：# rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p><p> </p><p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p><p> </p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.559.0-1.rhel9u2.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Server Update 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Server Update 5ファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプター"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Server Update 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"073cc30642e344b08af7bce7041b3707"}]},{"ProductId":"4273bdba1b2e4a8c9b15a6a2a834ba78","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK3"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK3"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK3"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK3"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK3"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK3"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK3"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK3"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDU、MO006400KWUDVドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3904224","DateModified":"2025-01-11T00:56:13","FileList":["cp064863.xml","cpqsetup.exe","KACM5ALSHPK3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"7ffea8486b363d5ac19f4d034d2c8868","Name":"cp064863.exe","Release":"2025-01-11T00:51:48","Revision":"B","SHA1Sum":"343ee3b6270c52fc6395c8931402e72a40d95501","SHA256Sum":"6882de5996e7845bf3b34a2462e6eaf6d4a14d4a31136cc3d1b36b3dcb3df07f","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDUおよびMO006400KWUDVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO000960KWUEA","TargetGUID":"562340a5-304f-3030-3936-304b57554541","Type":"nvme"},{"Id":"VO001920KWUEB","TargetGUID":"562340a5-304f-3130-3932-304b57554542","Type":"nvme"},{"Id":"VO003840KWUEC","TargetGUID":"562340a5-304f-3330-3834-304b57554543","Type":"nvme"},{"Id":"VO007680KWUED","TargetGUID":"562340a5-304f-3730-3638-304b57554544","Type":"nvme"},{"Id":"VO015360KWUEE","TargetGUID":"562340a5-304f-3531-3336-304b57554545","Type":"nvme"},{"Id":"MO000800KWUDR","TargetGUID":"4d2340a5-304f-3030-3830-304b57554452","Type":"nvme"},{"Id":"MO001600KWUDT","TargetGUID":"4d2340a5-304f-3130-3630-304b57554454","Type":"nvme"},{"Id":"MO003200KWUDU","TargetGUID":"4d2340a5-304f-3330-3230-304b57554455","Type":"nvme"},{"Id":"MO006400KWUDV","TargetGUID":"4d2340a5-304f-3630-3430-304b57554456","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T10:16:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWUEA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWUEB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWUEC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KWUED","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KWUEE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KWUDR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWUDT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWUDU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWUDV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9c21d4ef34874c3284e1dbd96ab732b3"}]},{"ProductId":"0d61334622ba44aeb0c163514d9f57b9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4515160","DateModified":"2025-01-11T11:04:15","FileList":["cp065089.xml","cpqsetup.exe","HVLAnAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"c52d28c667e40041c6beacf80dbd22f3","Name":"cp065089.exe","Release":"2025-01-11T11:00:11","Revision":"J","SHA1Sum":"e35934ee155915ab97513222121a5a7e34e6ef24","SHA256Sum":"837d477603a3adef06c0add0386e8c98710f277b9505e932e989ad765427f2de","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000GWKGVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T10:47:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2..</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2..</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2..</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"825f8f70031e41b6b87a9ca3c7e76052"}]},{"ProductId":"1359633a2c01457995b30369968ffed3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK3"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK3"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK3"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK3"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK3"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK3"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK3"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK3"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDU、MO006400KWUDV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19366939","DateModified":"2025-03-06T07:01:14","FileList":["/CP065994_BUILD_6.data","/CP065994.vmexe64","/CP065994.vmfile","/CP065994_VMw.zip","/CP065994.xml","/payload.json","/CP065994_VMw.zip/index.xml","/CP065994_VMw.zip/vendor-index.xml","/CP065994_VMw.zip/metadata.zip","/CP065994_VMw.zip/vib20/CP065994/HPE_bootbank_CP065994_HPK3.6-8.0.0.20613240.vib","/CP065994_VMw.zip/metadata.zip/vendor-index.xml","/CP065994_VMw.zip/metadata.zip/vmware.xml","/CP065994_VMw.zip/metadata.zip/vibs/CP065994--6913741902609280633.xml","/CP065994_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065994_HPK3.6-8.0.0.20613240.xml"],"MD5Sum":"adeea09459c3aee184ccca2c5dd9b0e9","Name":"CP065994.zip","Release":"2025-03-06T07:00:22","Revision":"B","SHA1Sum":"65ff36c7edf4327e73e4e9d441e3c4568e6eedf0","SHA256Sum":"e7add12e8089f3ab9fdeeb95d82f6a2518df528724ecf52dfaa077388817c02e","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"TypeOfChange":"1","Version":"HPK3","VibList":[{"Name":"CP065994","Version":"HPK3.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP040631.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe64&nbsp;is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPXXXXXX.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe64&nbsp;is executable by using the command:</li></ul><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPXXXXXX.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp;./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi  - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDU、MO006400KWUDVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO000960KWUEA","TargetGUID":"562340a5-304f-3030-3936-304b57554541","Type":"nvme"},{"Id":"VO001920KWUEB","TargetGUID":"562340a5-304f-3130-3932-304b57554542","Type":"nvme"},{"Id":"VO003840KWUEC","TargetGUID":"562340a5-304f-3330-3834-304b57554543","Type":"nvme"},{"Id":"VO007680KWUED","TargetGUID":"562340a5-304f-3730-3638-304b57554544","Type":"nvme"},{"Id":"VO015360KWUEE","TargetGUID":"562340a5-304f-3531-3336-304b57554545","Type":"nvme"},{"Id":"MO000800KWUDR","TargetGUID":"4d2340a5-304f-3030-3830-304b57554452","Type":"nvme"},{"Id":"MO001600KWUDT","TargetGUID":"4d2340a5-304f-3130-3630-304b57554454","Type":"nvme"},{"Id":"MO003200KWUDU","TargetGUID":"4d2340a5-304f-3330-3230-304b57554455","Type":"nvme"},{"Id":"MO006400KWUDV","TargetGUID":"4d2340a5-304f-3630-3430-304b57554456","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:21:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWUEA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWUEB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWUEC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KWUED","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KWUEE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KWUDR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWUDT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWUDU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWUDV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cba9f17f0d1d4a0bad974e39adc53f48"}]},{"ProductId":"a905a1ce40514e0aba7f765d4f2557ae","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves data integrity.&nbsp;</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs and provide a minor performance improvement.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5988859","DateModified":"2025-05-15T10:59:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/CP066528.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/TAMG09acHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066528.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066528.scexe"],"MD5Sum":"2c62d8528167def50db9f86ab0764b20","Name":"firmware-hdd-e0171a2936-HPG4-4.1.x86_64.rpm","Release":"2025-05-15T15:47:04","Revision":"D","SHA1Sum":"02ab0c172498cab61105f201e3948eacd67a7751","SHA256Sum":"87cdccfe24e73c6e3cd0e65bfb82e12a4c32fa0623a6fde422eae6ba3216c6b5","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"CP042460.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、およびMB018000GYCLLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:44:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"29490c1919014fd5acd7110b6ce7300e"}]},{"ProductId":"b271ca95088c47b0b57cf56bd9562a4c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD3"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD3"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD3"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5952707","DateModified":"2025-05-14T06:52:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/CP066522.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/KAPM6ALFHPD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066522.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066522.scexe"],"MD5Sum":"cb2147d0cc498ba726a6d97c00107049","Name":"firmware-hdd-8f501d6cf1-HPD3-3.1.x86_64.rpm","Release":"2025-05-14T11:29:53","Revision":"C","SHA1Sum":"d39e6f99a8d6e4cf3d7e787df6d34b1b33740b0f","SHA256Sum":"2100f659989d31c141ab176019afa01579840c713417a139d84c01e79d1f5d20","Size":"5MB","TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン:</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T08:04:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6d2cc028a6634968b95285c47072c535"}]},{"ProductId":"0094fb3b638e464a8e8862430ee704a7","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 driver."},{"Lang":"ja","Value":"このRPMには、HPEによるテストと承認済みのLinuxベースMellanox RoCE ConnectX-4、ConnectX-5、ConnectX-6、およびConnectX-7ドライバーが含まれます。"},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />​​​​​​​</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)</li></ul></li></ul><ul><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />​​​​​​​</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)</li></ul></li></ul><ul><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />​​​​​​​</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)</li></ul></li></ul><ul><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"}],"Files":[{"Bytes":"1724314","DateModified":"2025-05-19T17:25:08","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/09","./usr/lib/.build-id/09/1088dda5aabb87f35e5b8be743868725114eb3","./usr/lib/.build-id/16","./usr/lib/.build-id/16/a7a212912eec2587143b441f99644a36a01d49","./usr/lib/.build-id/20","./usr/lib/.build-id/20/8ca293a395692e9ed062a40e8d0524c7c3f6dd","./usr/lib/.build-id/27","./usr/lib/.build-id/27/e158b4578fd220b48f3ee2e54fb007585538dd","./usr/lib/.build-id/28","./usr/lib/.build-id/28/83dd989601db7f8e949b1c044e3278b06d5234","./usr/lib/.build-id/30","./usr/lib/.build-id/30/5e7111d66e4e43510d0855f3b7b374597f8188","./usr/lib/.build-id/38","./usr/lib/.build-id/38/b6961cfaed05d05ba03a2caa7e1e931e431c7c","./usr/lib/.build-id/52","./usr/lib/.build-id/52/7e60c93ddb0253f233e06da1c330b1b00c4cc9","./usr/lib/.build-id/58","./usr/lib/.build-id/58/c59329e9f4872732807d2f145d98f0a5ac5415","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/27b560541d46f57c9180a9e9aff3afccc1f461","./usr/lib/.build-id/6e","./usr/lib/.build-id/6e/b166f3bb992c1917d11d599caf923a8f445eda","./usr/lib/.build-id/77","./usr/lib/.build-id/77/78a2ce38f00e0e1e4cd2627cb69f5ff23f0c53","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/fba235fea1fa0d8c2f4868d279537f400fc8d2","./usr/lib/.build-id/81","./usr/lib/.build-id/81/4e63a405eaf8e0720a4d97035839f234a02c9a","./usr/lib/.build-id/94","./usr/lib/.build-id/94/8941eae1cbfc9be2087590fc42935430a3ff35","./usr/lib/.build-id/98","./usr/lib/.build-id/98/6ed701d84b0170b3262e0666237eac4639defe","./usr/lib/.build-id/9d","./usr/lib/.build-id/9d/b4efd9c8c7cf9adcff84e85fccdc6b568b392e","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/e4daa16f2c79a9699079fa6178e8a4d160226e","./usr/lib/.build-id/d2","./usr/lib/.build-id/d2/2e4821cffe5a66291e1d449d1437a925921dae","./usr/lib/.build-id/df","./usr/lib/.build-id/df/d094e043d0413c10a5ce6bc71a1a9ba2be3f90","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/8e30d1245fc346b603ea05cabb35b3e430e1e3","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.56.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.3.56.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.56.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.56.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.56.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.56.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"95fef38ae84435d5cbe27d76a7bcaea8","Name":"mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm","Release":"2025-05-19T15:45:02","Revision":"","SHA1Sum":"242440ec419dd499887905048d2bfacd58a300ef","SHA256Sum":"9be120609903adec12539bb97e2e3837cfcef5b8af6fcde40d9385ef271b5089","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"25.01-0.6.0.1"},{"Bytes":"2463863","DateModified":"2025-05-19T17:20:51","FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-testmod.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"MD5Sum":"2e2ae925f92c1944b8f26bcdfb11c599","Name":"kmod-mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm","Release":"2025-05-19T15:45:02","Revision":"","SHA1Sum":"fe8c22a43fb2ff1249e2e0cf959ba9501cff6cde","SHA256Sum":"6ebe2967986eb18ab11fb16a64833abac4eca13355c3a0e9b75443769f4f17ef","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"25.01-0.6.0.1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm</strong>&nbsp;<strong>&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm</strong>&nbsp;<strong>&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br /><br />To install or upgrade the driver:<br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp;or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm&nbsp;kmod-mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.rhel9u5.x86_64.rpm</strong>&nbsp;<strong>&nbsp;</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 Driver for Red Hat Enterprise Linux 9 Update 5 (x86_64)"},{"Lang":"ja","Value":"HPE Mellanox RoCE ConnectX-4、ConnectX-5、ConnectX-6、およびConnectX-7ドライバーfor Red Hat Enterprise Linux 9 Update 5 (x86_64)"},{"Lang":"cn","Value":"HPE Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 Driver for Red Hat Enterprise Linux 9 Update 5 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0086","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30086","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T12:31:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 24.10-1.1.4.1</strong><strong>:</strong></p><ul><li>Enhanced firmware reset flow for Sync1 utilizing community-accepted hot reset kernel flow.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 24.10-1.1.4.1:</strong></p><ul><li>rte_eth_dev_start()&nbsp;performed unnecessary recreation of mlx5 control flow rules, resulting in increased delay of&nbsp;rte_eth_dev_start().</li><li>Firefly was not compliant with &quot;SyncE to 1pps Class B/C Transient response&quot; while using ConnectX7 FHHL adapter card.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン24.10-1.1.4.1には、次の新機能と変更が含まれています</strong><strong>。</strong></p><ul><li>コミュニティで承認されたホットリセットカーネルフローを活用したSync1のファームウェアリセットフローが強化されました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン24.10-1.1.4.1で修正されました。</strong></p><ul><li>rte_eth_dev_start() はmlx5制御フロールールの不要な再作成を実行し、その結果 rte_eth_dev_start() の遅延が増加しました。</li><li>Fireflyは、ConnectX7 FHHLアダプターカードを使用している間、「SyncEから 1ppsクラスB/C過渡応答」に準拠していませんでした。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 24.10-1.1.4.1</strong><strong>:</strong></p><ul><li>Enhanced firmware reset flow for Sync1 utilizing community-accepted hot reset kernel flow.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 24.10-1.1.4.1:</strong></p><ul><li>rte_eth_dev_start()&nbsp;performed unnecessary recreation of mlx5 control flow rules, resulting in increased delay of&nbsp;rte_eth_dev_start().</li><li>Firefly was not compliant with &quot;SyncE to 1pps Class B/C Transient response&quot; while using ConnectX7 FHHL adapter card.</li></ul>","Lang":"cn"}],"Version":"24.10-1.1.4.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"cn"}],"Version":"25.01-0.6.0.1"}],"SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"43f4fadf81fc466bbcac3412d321f4c6"}]},{"ProductId":"d7a820130b1346d2a8d4377d479232cf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18850575","DateModified":"2025-03-06T13:48:25","FileList":["/CP065958_BUILD_5.data","/CP065958.vmexe64","/CP065958.vmfile","/CP065958_VMw.zip","/CP065958.xml","/payload.json","/CP065958_VMw.zip/index.xml","/CP065958_VMw.zip/vendor-index.xml","/CP065958_VMw.zip/metadata.zip","/CP065958_VMw.zip/vib20/CP065958/HPE_bootbank_CP065958_HPD4.5-1OEM.800.1.0.20613240.vib","/CP065958_VMw.zip/metadata.zip/vendor-index.xml","/CP065958_VMw.zip/metadata.zip/vmware.xml","/CP065958_VMw.zip/metadata.zip/vibs/CP065958--6752308024534835670.xml","/CP065958_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065958_HPD4.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ae49d96f6a339f27b9dccef6175a470c","Name":"CP065958.zip","Release":"2025-03-06T13:47:37","Revision":"B","SHA1Sum":"2ed99a1c49f426e19c12fecaa486770ef1f03c41","SHA256Sum":"f56b49310d895eaa06200e158a95115e7502cc764aba495d11cccd3389b77d87","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"2","Version":"HPD4","VibList":[{"Name":"CP065958","Version":"HPD4.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040692.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO006400JWUGB","TargetGUID":"4d2340a5-304f-3630-3430-304a57554742","Type":"sas"},{"Id":"MO003200JWUGA","TargetGUID":"4d2340a5-304f-3330-3230-304a57554741","Type":"sas"},{"Id":"MO001600JWUFV","TargetGUID":"4d2340a5-304f-3130-3630-304a57554656","Type":"sas"},{"Id":"EO001600JWUGE","TargetGUID":"452340a5-304f-3130-3630-304a57554745","Type":"sas"},{"Id":"MO000800JWUFU","TargetGUID":"4d2340a5-304f-3030-3830-304a57554655","Type":"sas"},{"Id":"EO000800JWUGD","TargetGUID":"452340a5-304f-3030-3830-304a57554744","Type":"sas"},{"Id":"MO000400JWUFT","TargetGUID":"4d2340a5-304f-3030-3430-304a57554654","Type":"sas"},{"Id":"EO000400JWUGC","TargetGUID":"452340a5-304f-3030-3430-304a57554743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:44:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</a></li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"de5f63eab149463783b82001b23764bb"}]},{"ProductId":"b0d91a06dd9c4473a208b93b1c088e41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4428096","DateModified":"2025-01-11T00:32:15","FileList":["cp064858.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TACD6ALLGPK7.rel"],"MD5Sum":"7feea1fac71ef3fcabdd5ce72138d024","Name":"cp064858.exe","Release":"2025-01-11T00:27:54","Revision":"C","SHA1Sum":"66ad998c940fe6659011eec7ff0fea292c4d160b","SHA256Sum":"f55c9c31d8d2225e3a75c9d2a9c92961c24e37b37859cae279a1302bed86fb02","Size":"4MB","TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK7"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:36:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bd84dd8f923649f298b07b431857d1d1"}]},{"ProductId":"57a91e286d3e413c8468376551e64001","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWFWKおよびMB002000GWFWL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4250280","DateModified":"2025-01-11T12:54:12","FileList":["cp065095.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WRH620G6.rel"],"MD5Sum":"9e469f5fa071f38ec6d276ec9f542f19","Name":"cp065095.exe","Release":"2025-01-11T12:50:11","Revision":"J","SHA1Sum":"32e1a4030f145b751e2741d219b919a9258ace20","SHA256Sum":"9a6a92bbc584ec9cdf027ad76cf7ed4b1220bd92ba845aacb455adddabef1de5","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB001000GWFWK","TargetGUID":"4d2340a5-3042-3130-3030-30475746574b","Type":"sata"},{"Id":"MB002000GWFWL","TargetGUID":"4d2340a5-3042-3230-3030-30475746574c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T12:21:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWFWK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"abd55f024dad4770a6b1f8ab350a2fd7"}]},{"ProductId":"ce8ca413963e4458ade3268c0f9831f6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"QLogicドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"880161","DateModified":"2025-04-09T09:11:02","FileList":["/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip","/cp066315.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.85.0-1OEM.803.0.0.24022510.vib","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/vibs/qlnativefc--4967580275396612799.xml","/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510_24611039.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.85.0-1OEM.803.0.0.24022510.xml"],"MD5Sum":"039b875c214228f28a90f21f5f85834c","Name":"cp066315.zip","Release":"2025-04-09T09:10:01","Revision":"","SHA1Sum":"a5e52b2072e3238f218e3d83a3f4e2b506922803","SHA256Sum":"830fcfc58e810147b4b619ae06b30f7aaf6132d485176115f0e3bdbab8f12eec","Size":"859KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.3"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"qlnativefc","Version":"5.4.85.0-1OEM.803.0.0.24022510"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ul><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li><li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルドライバーコンポーネント for VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:54:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.83.1<br />このドライバーは、VMware ESXi 8.0u3でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2024.09.01"},{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.85.0-1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.85.0-1<br />このドライバーは、VMware ESXi 8.0u3でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.85.0-1<br />This driver is only supported on VMware ESXi&nbsp;8.0u3</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"qlnativefc:5.4.85.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.85.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e6307a46904e4adc8214e64498f63d2b"}]},{"ProductId":"074cd65cf284444dbd64a63e5f809ff6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB014000GWUDA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4664480","DateModified":"2025-01-10T09:06:15","FileList":["cp065017.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssATFG3.rel"],"MD5Sum":"733dd43cb0ff91460f3a5f304742db4c","Name":"cp065017.exe","Release":"2025-01-10T09:02:07","Revision":"C","SHA1Sum":"b0066916dd2bc42e6103263c2ffb604049b6e1f6","SHA256Sum":"6a9171e561d02b6e1929d35e0f3a17839aa46b1e7e93cee32ef9a261f71a849a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T08:11:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2a3cb2c333614f13ab550c9532b37c85"}]},{"ProductId":"78667359eec84fc9af9066672db940e0","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp065007.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.702"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8577809","DateModified":"2025-05-15T00:43:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/CP067244.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/cp065007.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/cp065007.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.702-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067244.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067244.scexe"],"MD5Sum":"fa265632fa134c05c5a092596882d495","Name":"firmware-spsgen10plus-04.04.04.702-2.1.x86_64.rpm","Release":"2025-05-15T05:34:30","Revision":"B","SHA1Sum":"138999d4cd5ba56bf995771bf62fa8ae463a81f0","SHA256Sum":"661194bee97b6f5e5324477ff08c6c807d885ca663ce99d4b2d2c4beea689a94","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.702"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p><p> </p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T05:33:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.702 (2.30_01_06_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.04.04.702 (2.30_01_06_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bd50dc1d0a974f47843139494885fec7"}]},{"ProductId":"b00b4afad66b4dd386d098e91550601d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP6."},{"Lang":"ja","Value":"この製品は、SUSE Linux Enterprise Server 15 SP6下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP6."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"38553","DateModified":"2025-04-24T09:48:39","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-233.0.152.2.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"ec3dc9f666f19c1cdb12eb927ea38f97","Name":"libbnxt_re-233.0.152.2-sles15sp6.x86_64.rpm","Release":"2025-04-24T09:47:04","Revision":"","SHA1Sum":"2c3f93916822dad8c98e17638313d91b05a656ed","SHA256Sum":"c4a95bea1c1dd856b9f5d5b8a6ffd2897e60078a775ffa9f3d7fe264aa444c01","Size":"37KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"233.0.152.2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCEライブラリfor SUSE Linux Enterprise Server 15 SP6"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhances RDMA functionality by enabling the RDMA flag update based on firmware capability.</p>","Fixes":"<ul><li>This product fixes the issue where Dynamic Interrupt Moderation fails to shut down properly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating the summary of a coredump file.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、ファームウェアの機能に基づいてRDMAフラグのアップデートを有効にすることで、RDMA機能を強化します。</p>","Fixes":"<ul><li>この製品は、ダイナミック割り込みモデレーションが適切にシャットダウンできない問題を修正します。</li><li>この製品は、コアダンプファイルを生成するときにコアダンプファイルデコーダーがクラッシュする問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhances RDMA functionality by enabling the RDMA flag update based on firmware capability.</p>","Fixes":"<ul><li>This product fixes the issue where Dynamic Interrupt Moderation fails to shut down properly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating the summary of a coredump file.</li></ul>","Lang":"cn"}],"Version":"232.0.155.5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.152.2"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"db0e704fada44715a9f7673595f93c13"}]},{"ProductId":"6d1ce52e0d6c4c48a4cc6f903852d87d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"},{"Lang":"ja","Value":"BIOS - ????ROM"},{"Lang":"cn","Value":"BIOS - ?? ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34226848","DateModified":"2025-06-16T08:25:10","FileList":["cp067580.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U47_2.42_06_13_2025.signed.flash"],"MD5Sum":"6c20dde5f68d96c65191507b91c21224","Name":"cp067580.exe","Release":"2025-06-16T08:22:43","Revision":"","SHA1Sum":"8225403de9be7fd44d1e76be19f5b0f1b106cd3e","SHA256Sum":"b758b40d5f0a12209fd10a9bab594dad237969a467046781cec6dd373f8b7bd0","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー(U47) "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:06:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.04.04.702 (2.30_01_06_2025) と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"09dd4d40b1b64f9e98c36b86d4921159"}]},{"ProductId":"4f319faf890642fc80a3d8719760c121","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"7.43"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"7.43"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"7.43"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"7.43"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_7.43.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"7.43"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のストレージコントローラー用のファームウェアを提供します。 HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10 コントローラー"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"25439811","DateModified":"2025-03-07T06:56:52","FileList":["/CP062902_BUILD_27.data","/CP062902.vmexe64","/CP062902.vmfile","/CP062902_VMw.zip","/CP062902.xml","/payload.json","/CP062902_VMw.zip/index.xml","/CP062902_VMw.zip/vendor-index.xml","/CP062902_VMw.zip/metadata.zip","/CP062902_VMw.zip/vib20/CP062902/HPE_bootbank_CP062902_7.43.27-8.0.0.20613240.vib","/CP062902_VMw.zip/metadata.zip/vendor-index.xml","/CP062902_VMw.zip/metadata.zip/vmware.xml","/CP062902_VMw.zip/metadata.zip/vibs/CP062902-8257824330434921899.xml","/CP062902_VMw.zip/metadata.zip/bulletins/Smart-Component-CP062902_7.43.27-8.0.0.20613240.xml"],"MD5Sum":"5e60fe305bac4d50ad5eed533be26241","Name":"CP062902.zip","Release":"2025-03-07T06:47:04","Revision":"","SHA1Sum":"d936649c4774b5d9b4dc48ed2f40a770e740a23c","SHA256Sum":"40badf0a2fe204f19feace3843b0fef118e62c106b5f3d282f4bb3977f4897d3","Size":"24MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"7.43","VibList":[{"Name":"CP062902","Version":"7.43.27-8.0.0.20613240"}]}],"Installation":{"Command":"CP062902.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10コントローラー"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-17T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for saving Managed SED master key and reset key in cipher text in controller NVRAM instead of clear text.</li><li>Changed temperature polling period from 1 minute to 5 minutes for HBA mode drives that are in low power state.</li><li>Added support for clearing UREs in unmapped LBA range of fault tolerant logical drives.</li><li>Improved random write and mixed read-write performance.</li><li>Added support for SED encryption configuration through Redfish interface.</li><li>Added support of Redfish Chassis implementation for UBM Backplanes.</li><li>Added Redfish ACTION:<ul><li>Storage.SetEncryptionKey</li></ul></li><li>Added support for Redfish property PATCH:<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>Added support for Redfish Status.Conditions property to resources:<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Added support for Redfish properties:<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS only)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>Added support for PLDM Type5 UBM PIC firmware flashing behind expander.</li></ul>","Fixes":"<ul><li>Fixed an issue where the host experienced BSOD while clearing the controller configuration.</li><li>Fixed controller lockups caused by incorrect address reads and partial RAM initialization for PCIe functions, leading to ECC errors.</li><li>Fixed issues with external storage.</li><li>Fixed issues with the SATA drive.</li><li>Fixed issues with the SED drive.</li><li>Fixed issues with the spare drive.</li><li>Corrected MCTP-related issues.</li><li>Fixed surface scan issues on the RAID 50.</li><li>Fixed issues encountered during heavy I/O operations.</li><li>Fixed volume issues on the failed drive.</li><li>Fixed issues for incorrect Severity reported in Redfish events.</li><li>Fixed issues for incorrect Status reported in Redfish resources.</li><li>Fixed an issue with improper capacity information in Redfish drive Name.</li><li>Fixed an issue where Redfish long running task status is not reported.</li><li>Fixed an issue where DurableNameFormat for RAID volumes are reported as UUID in RDE READ operations, but should be NAA.</li><li>Fixed an issue where failed to take ownership of, or to revert, a SED through Redfish.</li><li>Fixed an issue when a drive hosting a RAID 0 Volume is removed and reinserted, a VolumeOK event is not generated.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>マネージドSEDマスターキーとリセットキーを、クリアテキストではなく暗号化テキストでコントローラーNVRAMに保存するためのサポートが追加されました。</li><li>低電力状態にあるHBAモードドライブの温度ポーリング期間を1分から5分に変更しました。</li><li>フォールトトレラント論理ドライブのマップされていないLBA範囲のUREをクリアするためのサポートが追加されました。</li><li>ランダム書き込みと混合読み取り/書き込みのパフォーマンスが向上しました。</li><li>Redfishインターフェースを介したSED暗号化構成のサポートが追加されました。</li><li>UBMバックプレーンのRedfishシャーシ実装のサポートが追加されました。</li><li>Redfish ACTIONを追加しました：<ul><li>Storage.SetEncryptionKey</li></ul></li><li>RedfishプロパティPATCHのサポートが追加されました：<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>リソースにRedfish Status.Conditionsプロパティのサポートを追加しました：<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Redfishプロパティのサポートが追加されました：<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS のみ)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>エクスパンダーの背後でフラッシュするPLDM Type5 UBM PICファームウェアのサポートが追加されました。</li></ul>","Fixes":"<ul><li>ホストがコントローラーの設定をクリアしている際にブルースクリーンが発生する問題を修正しました。</li><li>不正なアドレス読み取りやPCIe機能のための部分的なRAM初期化が原因で発生するECCエラーによるコントローラーのロックアップを修正しました。</li><li>外部ストレージに関する問題を修正しました。</li><li>SATAドライブに関する問題を修正しました。</li><li>SEDドライブに関する問題を修正しました。</li><li>スペアドライブに関する問題を修正しました。</li><li>MCTP関連の問題を修正しました。</li><li>RAID 50の表面スキャンの問題を修正しました。</li><li>負荷の高いI/O操作中に発生した問題を修正しました。</li><li>故障したドライブのボリュームの問題を修正しました。</li><li>Redfishイベントで報告される重大度が誤っている問題を修正しました。</li><li>Redfishリソースで報告されるステータスが正しくない問題を修正しました。</li><li>Redfishドライブ名の容量情報が不適切である問題を修正しました。</li><li>Redfishの長時間実行タスクのステータスが報告されない問題を修正しました。</li><li>RAIDボリュームのDurableNameFormatがRDE READ操作でUUIDとして報告されるが、NAAであるべきである問題を修正しました。</li><li>Redfish経由でSEDの所有権を取得または元に戻すことができなかった問題を修正しました。</li><li>RAID 0ボリュームをホストしているドライブを取り外して再挿入すると、VolumeOKイベントが生成されない問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for saving Managed SED master key and reset key in cipher text in controller NVRAM instead of clear text.</li><li>Changed temperature polling period from 1 minute to 5 minutes for HBA mode drives that are in low power state.</li><li>Added support for clearing UREs in unmapped LBA range of fault tolerant logical drives.</li><li>Improved random write and mixed read-write performance.</li><li>Added support for SED encryption configuration through Redfish interface.</li><li>Added support of Redfish Chassis implementation for UBM Backplanes.</li><li>Added Redfish ACTION:<ul><li>Storage.SetEncryptionKey</li></ul></li><li>Added support for Redfish property PATCH:<ul><li>Storage.EncryptionMode</li><li>Storage.HotspareActivationPolicy</li><li>Drive.HostspareReplacementMode</li><li>Drive.HotspareType</li><li>Volume.Encrypted</li></ul></li><li>Added support for Redfish Status.Conditions property to resources:<ul><li>Drive</li><li>Port</li><li>StorageController</li><li>StorageController.CacheSummary</li><li>Volume</li></ul></li><li>Added support for Redfish properties:<ul><li>Drive.DriveFormFactor</li><li>Drive.FirmwareVersion</li><li>Drive.Manufacture (SAS only)</li><li>Drive.SlotCapableProtocols</li><li>StorageController.AssetTag</li><li>StorageController.Links.PCIeFunction</li><li>Volume.BlockSizeBytes</li><li>Volume.LogicalUnitNumber</li></ul></li><li>Added support for PLDM Type5 UBM PIC firmware flashing behind expander.</li></ul>","Fixes":"<ul><li>Fixed an issue where the host experienced BSOD while clearing the controller configuration.</li><li>Fixed controller lockups caused by incorrect address reads and partial RAM initialization for PCIe functions, leading to ECC errors.</li><li>Fixed issues with external storage.</li><li>Fixed issues with the SATA drive.</li><li>Fixed issues with the SED drive.</li><li>Fixed issues with the spare drive.</li><li>Corrected MCTP-related issues.</li><li>Fixed surface scan issues on the RAID 50.</li><li>Fixed issues encountered during heavy I/O operations.</li><li>Fixed volume issues on the failed drive.</li><li>Fixed issues for incorrect Severity reported in Redfish events.</li><li>Fixed issues for incorrect Status reported in Redfish resources.</li><li>Fixed an issue with improper capacity information in Redfish drive Name.</li><li>Fixed an issue where Redfish long running task status is not reported.</li><li>Fixed an issue where DurableNameFormat for RAID volumes are reported as UUID in RDE READ operations, but should be NAA.</li><li>Fixed an issue where failed to take ownership of, or to revert, a SED through Redfish.</li><li>Fixed an issue when a drive hosting a RAID 0 Volume is removed and reinserted, a VolumeOK event is not generated.</li></ul>","Lang":"cn"}],"Version":"7.11"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support ESXi&nbsp;9</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support ESXi&nbsp;9</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support ESXi&nbsp;9</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.43"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8b9e6674e08f45ae9d3cbce47825d4ca"}]},{"ProductId":"C8510","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.2.537.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.2.537.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.2.537.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4366872","DateModified":"2024-07-30T03:13:20","FileList":["cp058604.xml","cpqsetup.exe","elxdrvr-fc-14.2.537.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"37e9dd1641b1df66f1af2b684c5fc015","Name":"cp058604.exe","Release":"2024-07-30T03:10:38","Revision":"b","SHA1Sum":"2bc8dcd51c4387dffde3b99dbd5cb949417ed0e4","SHA256Sum":"00d5522746f05af5bf17e862321f839d19a50ad0175f04f812cd90014015d22e","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.2.537.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2016"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-10-22T05:10:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.2.537.0にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>","Fixes":"","Lang":"cn"}],"Version":"14.2.537.0"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p><p>&nbsp;</p><p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Fixes":"<p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Lang":"en"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p><p>&nbsp;</p><p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Fixes":"<p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.2.537.0</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p><p>&nbsp;</p><p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Fixes":"<p>Fixed the following:</p><p>Apps AutoPilot installer Windows (from 14.2.555.0 to 14.2.589.31),<br />APInstall fails on Win 2019 Server Core. unable to find library oledlg.dll</p>","Lang":"cn"}],"Version":"14.2.537.0"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"97280984c2244463bd328b630122b3ca"}]},{"ProductId":"594618f566cc4fbca055e8866278e53d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"cn","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"Lang":"ja","Value":"Smart Storage Administrator（SSA）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p><p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p><p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p><p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p><p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p><p><strong>The following are known issues:</strong></p><ul><li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li></ul>"},{"Lang":"ja","Value":"<p>SSAを使用するとき、ユーザーは、定義されている期間使用していなかった場合、自動的にログアウトされ、再ログインが必要になります。</p><p>SSAを使用する場合、Webベースのマネジメントデバイスホームページ上で、\"オプション\"にある\"匿名アクセス\"を有効にする必要があります。</p><p>別のSSAセッション上の現在設定されているコントローラーをクリックすると、他のSSAセッションを上書きするかキャンセルするかのメッセージが表示されます。他のSSAセッションを上書きすると、他のセッションでの保存されていない変更は、廃棄されます。</p><p>SSAをアンインストールするには、Windowsのコントロールパネルのアプリケーションの追加と削除を使用します。</p><p>Windows上のローカルアプリケーションモードでSSAを動作させるには、Internet Explorerがデフォルトのブラウザーでなければなりません。</p><p><strong>既知の問題について</strong></p><ul><li>デバイスホームページのログインが初回時に動作しない場合があります。デバイスホームページリンクをクリックし、再度ログインしてください。</li></ul>"},{"Lang":"cn","Value":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p><p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p><p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p><p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p><p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p><p><strong>The following are known issues:</strong></p><ul><li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li></ul>"}],"Files":[{"Bytes":"10384200","DateModified":"2025-04-09T07:43:17","FileList":["cp066717.xml","cpqsetup.exe","genericmsi.dll","SSA64580_X64.msi","SSA_RELNOTES.txt"],"MD5Sum":"3bc5a8cdeed57decf1d06d8267bf993b","Name":"cp066717.exe","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"d787f00305c3b879cf5d6b2d9b182fc1cf150a28","SHA256Sum":"2cc63138518cf07883aeb05180da6e6408378539dbd186a4c433d41d2a12dc66","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <P>From that drive and directory, execute the downloaded file. <P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<P>[インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</P>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <P>From that drive and directory, execute the downloaded file. <P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) for Windows 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:32:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssa.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"72b60c0935f34af89709615a8b32cffb"}]},{"ProductId":"c19eee3c7a1046a4aeaff35e462fce56","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19268026","DateModified":"2025-03-06T05:49:38","FileList":["/CP066001_BUILD_4.data","/CP066001.vmexe64","/CP066001.vmfile","/CP066001_VMw.zip","/CP066001.xml","/payload.json","/CP066001_VMw.zip/index.xml","/CP066001_VMw.zip/vendor-index.xml","/CP066001_VMw.zip/metadata.zip","/CP066001_VMw.zip/vib20/CP066001/HPE_bootbank_CP066001_HPG9.4-1OEM.800.1.0.20613240.vib","/CP066001_VMw.zip/metadata.zip/vendor-index.xml","/CP066001_VMw.zip/metadata.zip/vmware.xml","/CP066001_VMw.zip/metadata.zip/vibs/CP066001--7218200217336899870.xml","/CP066001_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066001_HPG9.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"abe72ced5c923a4b757e10750df2192d","Name":"CP066001.zip","Release":"2025-03-06T05:48:52","Revision":"E","SHA1Sum":"5b91b5533419833250abd88f2487b550ca7bd866","SHA256Sum":"d834932ff51f4036b9704c3fccefcff6fde525327f922bf2e074ea81f93cddc1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9","VibList":[{"Name":"CP066001","Version":"HPG9.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040658.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:59:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"082b90a7fe714b2dba1a8cee129c9946"}]},{"ProductId":"f3f8a4081d78499e9a2dd9c8d9fb4059","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_4p71_PLDMoMCTP_8002003C.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>8002003C</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td><td>8002003C</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td><td>8002003C</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524447","DateModified":"2025-03-28T06:37:48","FileList":["HPE_E810_CQDA2_4p71_PLDMoMCTP_8002003C.HPb","HPE_E810_CQDA2_4p71_PLDMoMCTP_8002003C.xml","payload.json"],"MD5Sum":"f9f7c4b09d3924cfb4271649f5f9e712","Name":"HPE_E810_CQDA2_4p71_PLDMoMCTP_8002003C.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"8b871527dd9866c2d5862ad52257fb626e3c0a53","SHA256Sum":"a685f4bf2c22b8ebcf61ae328bc66865ebad4e9e1024865e4e2e8ef89749b220","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:33:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"c548e51f97194a5cac22a4bc37aa4bcb"}]},{"ProductId":"96853662d13b4def814a5c153a747271","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"4537608","DateModified":"2025-01-11T10:49:19","FileList":["cp065047.xml","cpqsetup.exe","HVLAnAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"78dcb82722aa4e6dfea374f54463c6ed","Name":"cp065047.exe","Release":"2025-01-11T10:45:31","Revision":"F","SHA1Sum":"db4e7e16d1877d40284b51c285968f6ceff55029","SHA256Sum":"9cc8a884b56512a4d851e07d4c70130806654082c51a983a2882672a656d114e","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000JWKGUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:02:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"211977b6d5a44c7db30905f765e7d4e7"}]},{"ProductId":"3a4168637f45404b864aa9e998210305","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SuSE Linux Enterprise Server 15 for Emulex Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージには、SUSE Linux Enterprise Server 15上でEmulexホストバスアダプターに対してHPE Storageファイバーチャネルアレイ接続を有効にするためのユーティリティとライブラリが含まれています。"},{"Lang":"cn","Value":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SuSE Linux Enterprise Server 15 for Emulex Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"810723","DateModified":"2025-06-12T05:17:10","FileList":["./opt/emulex/sles15sp6/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp6/x86_64/lib64/libdfc.so.14","./opt/emulex/sles15sp6/x86_64/lib64/libdfc.so.14.4.473","./opt/emulex/sles15sp6/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp6/x86_64/lib64/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.14","./usr/lib64/libdfc.so.14.4.473","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"MD5Sum":"e5917d2855aef890e0f74033fdd6250f","Name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.4.473.25-1.sles15sp6.x86_64.rpm","Release":"2025-06-12T05:14:27","Revision":"b","SHA1Sum":"193d0118c7c9e0c8e421b3ccf40f3ddda1d4aad7","SHA256Sum":"4df151a63dd2d67d89fa49b85264e477f0333c085f91a8cbe6e16c8853fc8d24","Size":"791KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"TypeOfChange":"1","Version":"14.4.473.25"},{"Bytes":"810728","DateModified":"2025-06-12T05:22:16","FileList":["./opt/emulex/sles15sp7/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp7/x86_64/lib64/libdfc.so.14","./opt/emulex/sles15sp7/x86_64/lib64/libdfc.so.14.4.473","./opt/emulex/sles15sp7/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp7/x86_64/lib64/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.14","./usr/lib64/libdfc.so.14.4.473","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"MD5Sum":"ad9a33f10fd6c639ee5167f060c67945","Name":"HPE-CNA-FC-Emulex-Enablement-Kit-14.4.473.25-1.sles15sp7.x86_64.rpm","Release":"2025-06-12T05:14:27","Revision":"b","SHA1Sum":"45fac1e58b7e5a8899bdc2c254828f8af06668ff","SHA256Sum":"54c1fdd7456ad4ddb5f014e651e697fd9ca30003a28d8ab261a69cf4b2ffc644","Size":"791KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"TypeOfChange":"1","Version":"14.4.473.25"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p><p>&nbsp;</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server&nbsp;15 service pack 5 and&nbsp;SuSE Linux Enterprise Server&nbsp;15 service pack 6&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --reinstall &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>イネーブルメントキットのインストール前にターゲット環境にlibHBAAPIパッケージをインストールしておく必要があります。（存在していない場合、libHBAAPIパッケージはオペレーティングシステムのインストールメディアから取得することができます。）</p><p> </p><p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>同じイネーブルメントキットバージョンの再インストールは、SuSE Linux Enterprise Server 15 Service Pack5およびSuSE Linux Enterprise Server 15 Service Pack6で--reinstallオプションを使用して実行する必要があります。</p><p>例：rpm –Uvh HPE-CNA-FC-Emulex-Enablement-Kit-<version>.<OS>.<architecture>.rpm --reinstall              </p><p> 詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p><p>&nbsp;</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server&nbsp;15 service pack 5 and&nbsp;SuSE Linux Enterprise Server&nbsp;15 service pack 6&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --reinstall &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p><p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters for SuSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Emulexファイバーチャネルイネーブルメントキットforホストバスアダプター -  SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters for SuSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-12T04:56:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.25</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.25にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.25</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.25"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:<br /><br />SUSE Linux Enterprise 15.7</p><p>Updated to&nbsp;version14.4.473.25</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support For:<br /><br />SUSE Linux Enterprise 15.7</p><p>Updated to&nbsp;version14.4.473.25</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:<br /><br />SUSE Linux Enterprise 15.7</p><p>Updated to&nbsp;version14.4.473.25</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.25"}],"SWKeys":[{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit","SWKeyExpectedPath":"software:rpm"},{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit","SWKeyExpectedPath":"software:rpm"},{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit","SWKeyExpectedPath":"software:rpm"},{"Name":"HPE-CNA-FC-Emulex-Enablement-Kit","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c9dc9c6017004bd4a0a28c5e58d4706a"}]},{"ProductId":"6d5b098230e341e9881e9381bf19ba96","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-iavf) to (iavf). Now we revert this change from (iavf) to (<strong>hp</strong>-iavf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-iavf and kmod-iavf are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-iavf and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-iavf-4.9.1-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-iavf）から（iavf）に変更されました。この変更を（iavf）から（<strong>hp</strong>-iavf）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-iavfとkmod-iavfはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-iavf-4.9.1-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-iavfによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-iavf) to (iavf). Now we revert this change from (iavf) to (<strong>hp</strong>-iavf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-iavf and kmod-iavf are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-iavf-4.9.1-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-iavf and then install the updated RPM.</p>"}],"Files":[{"Bytes":"179917","DateModified":"2025-04-01T08:18:06","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-iavf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/f44b832c5b4a2fd3e7a2f3bb544391eb900104","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"MD5Sum":"e7bdf5189751f6b57b179b1c2117c225","Name":"kmod-hp-iavf-4.13.4-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T08:12:05","Revision":"B","SHA1Sum":"4422960dc7250f3af2826e7fea09cb3cbcddf588","SHA256Sum":"5de5361084049c12acc9095f03899d464e802cff4a3caa674c29fac0584336d5","Size":"175KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.4-1"},{"Bytes":"180110","DateModified":"2025-04-01T08:22:22","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-iavf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/a73b6b9e656255cc3b8d5399bfd5c659f28718","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"MD5Sum":"8a9f086a63f80c7cf9118066202b7fe2","Name":"kmod-hp-iavf-4.13.4-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T08:12:05","Revision":"B","SHA1Sum":"8763eec6bf5fdb237b4be52e0177fea737469c17","SHA256Sum":"5fb0e6108ec8fa85f5bf7c76cae2b3504a4ce707e3fc514ec1d680d6cac7c098","Size":"175KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel iavf ドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"15FF","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15ff8086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37cd","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"0dd5","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:17:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"4.12.5-1"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"4.13.4-1"}],"SWKeys":[{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"04f238a593334138862984cf5972ae52"}]},{"ProductId":"e774fea9b642407a9f2687df296d352e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1412896","DateModified":"2025-03-28T08:26:18","FileList":["cp065360.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"MD5Sum":"a4c6d2d2a9346f087585dcac3ea4aa2e","Name":"cp065360.exe","Release":"2025-03-28T08:12:11","Revision":"","SHA1Sum":"63a697e5d2d2b898f4ae01b5ae17637c88b79830","SHA256Sum":"f5dd8b07f4f21aeb9fa76a32ca3fbbf2817c552ab072d404c4be730b9ae3816d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T08:22:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"1.14.203.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes the registry of RdmaRoceFrameSize, changing the default value from 1 to 1024.</li><li>This product fixes an issue wher the Large Send Offload(LSO) is not working.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the registry of RdmaRoceFrameSize, changing the default value from 1 to 1024.</li><li>This product fixes an issue wher the Large Send Offload(LSO) is not working.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes the registry of RdmaRoceFrameSize, changing the default value from 1 to 1024.</li><li>This product fixes an issue wher the Large Send Offload(LSO) is not working.</li></ul>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ba6070dd4fe74a3a9ce556ab65af395e"}]},{"ProductId":"a162b7594d8d4a02bf2f3f7d9fe2609d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel NICs Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;(This generic binary RPM is the same with hp-igb-kmp-default version 6.14.16）<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb-kmp-default) to (igb-kmp-default). Now we revert this change from (igb-kmp-default) to (<strong>hp</strong>-igb-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-igb-kmp-default and igb-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e igb-kmp-default and then install the updated RPM.<br />&nbsp;&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースigb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません (この汎用バイナリRPMはhp-igb-kmp-defaultバージョン6.14.16と同じです)<br />    - RPMパッケージ名は（<strong>hp</strong>-igb-kmp-default）から（igb-kmp-default）に変更されました。この変更を（igb-kmp-default）から（<strong>hp</strong>-igb-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-igb-kmp-defaultとigb-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにigb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e igb-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。<br />  </p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;(This generic binary RPM is the same with hp-igb-kmp-default version 6.14.16）<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-igb-kmp-default) to (igb-kmp-default). Now we revert this change from (igb-kmp-default) to (<strong>hp</strong>-igb-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-igb-kmp-default and igb-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install igb-kmp-default-5.14.16_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e igb-kmp-default and then install the updated RPM.<br />&nbsp;&nbsp;</p>"}],"Files":[{"Bytes":"155120","DateModified":"2025-04-01T08:32:58","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/hp-igb","./lib/modules/5.14.21-150500.53-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"MD5Sum":"a7ba55be0945fbfb78ce985d0e2edbda","Name":"hp-igb-kmp-default-6.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T08:26:06","Revision":"","SHA1Sum":"ccca25e564abacd5c4135a7e6e5c02fa6c746189","SHA256Sum":"b8e88bda5f1cbf6d1cbba42284c40df15b9541cf90c88ab13abec58ead8f47ac","Size":"151KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.18.7-1"},{"Bytes":"180147","DateModified":"2025-04-01T08:38:03","FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-igb","./lib/modules/6.4.0-150600.21-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"MD5Sum":"85bf7606f2372d270abf280390de93a6","Name":"hp-igb-kmp-default-6.18.7_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T08:26:06","Revision":"","SHA1Sum":"9ba01bf0dd51fd2ed46ec1d89b53660b2801ab8e","SHA256Sum":"42c4c587368105ff65f133444f126680f51f84398af782e85e9c0bffd1acbed1","Size":"175KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.18.7-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel igbドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:12:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"cn"}],"Version":"6.17.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"6.18.7-1"}],"SWKeys":[{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"753411979d734eb19ab05458b72b4aba"}]},{"ProductId":"e4dd84a160cc43f1b620391e92c1a737","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK4</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK4</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK4</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK4</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK4</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK4</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6533725","DateModified":"2025-05-14T06:59:50","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/CP066545.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/TACM6ALFGPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066545.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066545.scexe"],"MD5Sum":"fa6513865c91d44b6d5fb58ced8d5025","Name":"firmware-hdd-1a541ed00d-GPK5-8.1.x86_64.rpm","Release":"2025-05-14T11:34:09","Revision":"H","SHA1Sum":"bbca7a4dc7bc1390a412355c77bd79560a87a5cb","SHA256Sum":"d202ef3a6a8633d357a9cc58f314fbda11d2383326290e6040aac7d5ebd3f802","Size":"6MB","TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK5"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor Linux（x64）- KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T13:21:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"GPK5"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4a29c09aacf43838832ec7d2367b751"}]},{"ProductId":"ed78d2df04834204b8977e0aaa96c64a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1544352","DateModified":"2025-03-28T08:02:18","FileList":["cp065359.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"cbaaf16d39e571404eac724d8726cd62","Name":"cp065359.exe","Release":"2025-03-28T07:48:04","Revision":"","SHA1Sum":"0d5a856e4a7b3e648cb7848a40ce216229bb777d","SHA256Sum":"1140241b1e9d96fa6fa278f245cf6f1858fc7d54b0e12cc3f46b287a0cdb8abb","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T08:22:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40eb68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"08a951b693a542e6a6176cef7005c7f1"}]},{"ProductId":"95cd675c9c4947eda03bc921bfff84c3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-3047575a564c","Version":"HPG3"},{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-3047575a564e","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB006000GWZVL and MB008000GWZVN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1281827","DateModified":"2024-07-09T04:20:19","FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAeG3.HPb","Toshiba_MG08Air_TAMG08ADAeG3.xml"],"MD5Sum":"30dd23d4e1b0b2985979edc5276ab653","Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","Release":"2024-07-09T04:16:07","Revision":"","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"TypeOfChange":"2","Version":"HPG3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000GWZVL","TargetGUID":"4d2340a5-3042-3630-3030-3047575a564c","Type":"sata"},{"Id":"MB008000GWZVN","TargetGUID":"4d2340a5-3042-3830-3030-3047575a564e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T03:43:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>&nbsp;which will be active on&nbsp;24-April-2024.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li><li>詳しくは、HPEカスタマーアドバイザリ: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>（2024年4月24日に有効になります）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00138902en_us</a>&nbsp;which will be active on&nbsp;24-April-2024.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity. &nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB006000GWZVL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GWZVN","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"22b25cb7056247fca6f226ad387ab8a6"}]},{"ProductId":"d3e8a053234f49d9a3735931f34c77c7","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9007966","DateModified":"2025-05-20T20:33:36","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/CP067184.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/U43_3.60_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.60_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067184.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067184.scexe"],"MD5Sum":"cdf88a511ef425c1d9486b8c16e164f6","Name":"firmware-system-u43-3.60_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-21T01:26:04","Revision":"","SHA1Sum":"fd90f5d0c76487e2c85c35f5556ff529edda0d3b","SHA256Sum":"d7b8fb01dd219f1c0af51557af710889cbf31ace3ee4926336c46fc2cc908acf","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:47:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance.ThisÂ version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア05.01.05.005と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance.ThisÂ version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"282e2c21ad294d829e332e8a233d2cec"}]},{"ProductId":"8fe22752c5324386870794853904b4ba","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"24825000","DateModified":"2025-07-10T10:55:00","FileList":["CHIF/","CHIF/X64/","cp039984.exe","cp039985.exe","cp040013.exe","cp041932.exe","cp049467.exe","cp053254.exe","cp053256.exe","cp061694.exe","cp061730.exe","cp067430.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"MD5Sum":"8e02224936529237e13c8fafa2b22f11","Name":"cp067430.exe","Release":"2025-07-10T10:51:46","Revision":"","SHA1Sum":"2558dc7b5419dc8f433e251f2b75d3c753151db3","SHA256Sum":"fc5a0f18355bca4b1e2dde95154e1d00b0419c08c0282fb0162bcc6ef8f8f6f2","Size":"23MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5f36672a","20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"TypeOfChange":"1","Version":"6.2.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ol><li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li><li>Change to the directory.</li><li>Run the .exe file by double-clicking it. A dialog box will display.</li><li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li></ol>"},{"Lang":"ja","Value":"<ol><li>Smartコンポーネント (cpxxxxxx.exe)ファイルをサーバー上のソフトウェアをインストールしたいローカルディレクトリにダウンロードします。</li><li>ディレクトリに移動します。</li><li>.exeファイルをダブルクリックすることで実行します。ダイアログボックスが表示されます。</li><li>インストールボタンをクリックしてSmart Update Toolsをインストールします。</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Windows x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Windows x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T08:51:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.1.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.2.0.0"}],"SWKeys":[{"Name":"hpsut.exe","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett-Packard\\HPSUT\\bin"},{"Name":"sut.exe","SWKeyExpectedPath":"%ProgramFiles%\\SUT\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"67362ac752ab407d8f4bf8809227fd55"}]},{"ProductId":"38d3787c49804ab1b404f61b3cd58354","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"3441392","DateModified":"2025-01-11T07:07:19","FileList":["cp065065.xml","cpqsetup.exe","GPM1645ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"3b6d49971f40e5249ef02cfcbd4ada37","Name":"cp065065.exe","Release":"2025-01-11T07:03:09","Revision":"C","SHA1Sum":"97144cd928f8d4380685c85b31bced0e7d6487c4","SHA256Sum":"2c3c1ea0225ec4d86a5680214d474c01e8d954f192035018a67eaeb59db2dabd","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:14:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6d790f894e5f478fa1f5f02962010122"}]},{"ProductId":"dc0fcbf999ba4988aa8b4eae8e8c9889","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />      </strong>HPG1<br /><br /><strong>最新の推奨またはクリティカルバージョン：<br />      </strong>なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"21446233","DateModified":"2025-03-06T04:53:54","FileList":["/CP065949_BUILD_2.data","/CP065949.vmexe64","/CP065949.vmfile","/CP065949_VMw.zip","/CP065949.xml","/payload.json","/CP065949_VMw.zip/index.xml","/CP065949_VMw.zip/vendor-index.xml","/CP065949_VMw.zip/metadata.zip","/CP065949_VMw.zip/vib20/CP065949/HPE_bootbank_CP065949_HPG1.2-1OEM.800.1.0.20613240.vib","/CP065949_VMw.zip/metadata.zip/vendor-index.xml","/CP065949_VMw.zip/metadata.zip/vmware.xml","/CP065949_VMw.zip/metadata.zip/vibs/CP065949--1036886056504614711.xml","/CP065949_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065949_HPG1.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"369669fe0af73a1a3c7b0e628482c47d","Name":"CP065949.zip","Release":"2025-03-06T04:53:03","Revision":"C","SHA1Sum":"0815a37a220d6eef63435ebdf6ca112c9b69f540","SHA256Sum":"685d6193676c04c7ec5604a22f20d0eced849a8e01f7da433b34f7eaa5d82037","Size":"20MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065949","Version":"HPG1.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040671.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives."},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GZXRU、VK000480GZXRF、VK000960GZXQU、VK001920GZXQV、VK003840GZXRH、およびVK007680GZXRTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK001920GZXQV","TargetGUID":"562340a5-304b-3130-3932-30475a585156","Type":"sata"},{"Id":"VK003840GZXRH","TargetGUID":"562340a5-304b-3330-3834-30475a585248","Type":"sata"},{"Id":"VK007680GZXRT","TargetGUID":"562340a5-304b-3730-3638-30475a585254","Type":"sata"},{"Id":"VK000960GZXQU","TargetGUID":"562340a5-304b-3030-3936-30475a585155","Type":"sata"},{"Id":"VK000480GZXRF","TargetGUID":"562340a5-304b-3030-3438-30475a585246","Type":"sata"},{"Id":"VK000240GZXRU","TargetGUID":"562340a5-304b-3030-3234-30475a585255","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:34:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3b34a42dbd6f4c9aa3887be86849e669"}]},{"ProductId":"4ecda510f4cf4aef9ac80ad782d1c36e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.50_03_21_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.50 (03/21/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"18150120","DateModified":"2025-03-24T08:22:46","FileList":["A41_3.50_03_21_2025.signed.flash","cp066439.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"0aa3a1a25de1f0eedf3f9c0090c8ecb8","Name":"cp066439.exe","Release":"2025-03-24T08:20:23","Revision":"","SHA1Sum":"e34d766064fe6daac68cd5bb5d051b79f0ff9bbf","SHA256Sum":"6eb42d69ac1fc778d21ce09c0898f9d260128e9eecfbe5812f9188b43b2f518a","Size":"17MB","TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"1","Version":"3.50_03-21-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325 Gen10 (A41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:19:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Lが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>機能強化/新しい機能：</strong></p><p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.L for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"3.42_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>This revision of the System ROM includes AMD reference code NaplesPI 1.0.0.Q for AMD 1st Generation EPYC processors.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"3.50_03-21-2025"}],"SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"da6c9845084147d7b1be8cb4c5082633"}]},{"ProductId":"bca5397d7ba147ddbb0eb4fee4d4d567","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.01"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.01"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.01"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.01"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4270029","DateModified":"2025-06-24T05:43:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/CP067637.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/bk020501.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/create_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/libHBAAPI.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/libHBAAPI.so.2","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/libqlcoutil.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/libqlsdm.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/mh021101.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/qlafwupdate.sub","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/remove_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2025.05.02-1.1/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067637.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067637.scexe"],"MD5Sum":"834ca982905c05b1455475ed455612e2","Name":"firmware-fc-qlogic-2025.05.02-1.1.x86_64.rpm","Release":"2025-06-24T10:31:36","Revision":"","SHA1Sum":"381a6e1f07c26fbe435af695deecb97ec2e97454","SHA256Sum":"868ec1774ac7d2854273fed7726eedfa6be57c7437c424b6a420c708849252bc","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.05.02"}],"Installation":{"Command":"installer","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Action prior to the installation/upgrade of qlafwupdate on RHEL 10.x</strong></p><p>qlafwupdate utility depends on libcrypt.so.1 library. This library is not installed by default on RHEL 10.x. Please install libxcrypt-compat RPM to install libcrypt.so.1 library before using qlafwupdate utility.</p><p>&nbsp;</p><p>&nbsp;</p><p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />&nbsp;<br />1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />&nbsp;<br />2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />&nbsp;<br />When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.</p><p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p><p>&nbsp;</p><ul><li><p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p></li></ul>"},{"Lang":"ja","Value":"<p><strong>RHEL 10.xでのqlafwupdateのインストール/アップグレード前のアクション</strong></p><p>qlafwupdateユーティリティはlibcrypt.so.1ライブラリに依存します。このライブラリはRHEL 10.xではデフォルトでインストールされません。qlafwupdateユーティリティを使用する前に、libxcrypt-compat RPMをインストールしてlibcrypt.so.1ライブラリをインストールしてください。</p><p> </p><p> </p><p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br /> <br />1. ファームウェアインストレーションツール：rpm -Uvh <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールがfirmware-*フォルダーの/usr/lib/x86_64-linux-gnuに抽出されます（64ビットシステム）。<br /> <br />2. 使用するシステムの適切な場所へcdし、./setupを実行してファームウェアをアップデートします<br /> <br />ファームウェアインストレーションの完了後は、rpm -eコマンドを使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p><p>注記：フラッシュ操作中に\"No Adapter Found!\"というメッセージが ログに記録されることがあります。これらのメッセージは、ファームウェアフラッシュ操作の問題を示していないため、無視してかまいません。</p><p> </p><ul><li><p>/var/tmpフォルダーに読み取り/書き込み権限を付与することをお勧めします。/tmpまたは/var/tmpディレクトリで読み取り/書き込み(rw)権限が有効になっていない場合、Service Pack for ProLiant(SPP)を介したファームウェアの展開が失敗する場合があります。</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)"},{"Lang":"ja","Value":"QLogicファイバーチャネルホストバスアダプター用HPEファームウェアフラッシュ - Linux (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-24T08:56:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.02"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"840d82bb470f45dcbef9c8396b8a5ccb"}]},{"ProductId":"e79fad26938d4b788f99ac1b9d5aa529","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインROMフラッシュコンポーネントfor Windows - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p><p><strong>リリースバージョンおよび/または日付:</strong><br />     NA<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     NA<br /><br /><strong>前のファームウェアバージョン：</strong><br />     NA<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /><br /><strong>改善点/新しい機能：</strong></p><ul><li>最初のリリース</li></ul><p><strong>修正された問題点：</strong></p><p><strong>     </strong>なし</p><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p><p><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; NA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Initial Release</li></ul><p><strong>Problems Fixed:</strong></p><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3746928","DateModified":"2025-01-16T13:56:20","FileList":["Capitola-Release-1.27.bin.fw","cp065148.xml","cpqsetup.exe","payload.json","setup.dll"],"MD5Sum":"351cc17feee149c36090ca33712a073f","Name":"cp065148.exe","Release":"2025-01-16T13:45:19","Revision":"E","SHA1Sum":"2a964e72572dd815086bbc1c875fe860d05e9573","SHA256Sum":"9886133130e48ab77f92586d69016723d169751544c74f07939ddf2cd88552d6","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><p>&nbsp;</p><ul><li>Place the desired firmware to be updated in the directory, \\SPPxxxxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant</a></strong>から以下の手順に従ってください：</p><p> </p><ul><li>アップデートに必要なファームウェアを\\SPPxxxxxxx\\packagesディレクトリにコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><p>&nbsp;</p><ul><li>Place the desired firmware to be updated in the directory, \\SPPxxxxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware Windows (x64) - HPE Apollo 2000 Gen10 PlusバックプレーンエキスパンダーFW"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Id":"Apollon2800Gen10Plus","TargetGUID":"","Type":"agp"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-16T06:51:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Microsoft Windows Server 2025.&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Microsoft Windows Server 2025をサポートします。 </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Microsoft Windows Server 2025.&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"1.27"},{"ReleaseNotes":[{"Enhancements":"<p>Support Azure Stack HCI 23H2.&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support Azure Stack HCI 23H2.&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Azure Stack HCI 23H2.&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"1.27"}],"SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4a3ee2fcc92b4240b2b09f9b5fb44a25"}]},{"ProductId":"84d998355c4f4bc6997437e9a6c61fba","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp065000.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.105"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3342456","DateModified":"2025-05-15T00:37:19","FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/CP067242.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/cp065000.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/cp065000.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.105-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067242.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067242.scexe"],"MD5Sum":"abc02878d7ebf9dd48e0030366edf5f5","Name":"firmware-spsgen10-04.01.05.105-2.1.x86_64.rpm","Release":"2025-05-15T05:29:49","Revision":"B","SHA1Sum":"7525fe0780c3dbf085f9d915a3cdde425289bbe8","SHA256Sum":"44ec04cd5944202bd36fa6e9a3ff57293090b2fba1014c652d3db3c4360cb9b4","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.105"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T05:28:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.105は、システムROM 3.40 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 04.01.05.105は、システムROM 3.40 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d24d95b6be5b42679f82bd43de48a53b"}]},{"ProductId":"cdfe3840d6074900a4d11b774d3e5307","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作) ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"29748696","DateModified":"2025-04-22T13:47:58","FileList":["cp066777.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"3bee1e35614d63d80bf1bd154367b022","Name":"cp066777.exe","Release":"2025-04-22T13:45:47","Revision":"A","SHA1Sum":"514e4f4ac7dadf791418381344b92b544e1a1c07","SHA256Sum":"0e41f14c3a0170cd2a71d0074f2a6a77b9b7890388040295e1d7f2281c69b655","Size":"28MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.0.17"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - Windows x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T12:24:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>Changes included in component version 1.0.0.16(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>コンポーネントバージョン1.0.0.16(A)に含まれる変更：</strong></p><ul><li>コンポーネントメタデータに Azure Stack HCI 23H2のサポートが追加されました。</li></ul><p> </p><p><strong>バージョン12.28.2302には新機能や変更は含まれていません。</strong></p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>Changes included in component version 1.0.0.16(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.16"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.17"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fab8d90d6d734949ad99dd08071b4056"}]},{"ProductId":"7998b80f937f47828d4693eb2d620eec","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1242920","DateModified":"2025-03-28T09:09:19","FileList":["cp065282.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"4c15daffb817fb0efabe48ac9fc296e5","Name":"cp065282.exe","Release":"2025-03-28T08:54:43","Revision":"","SHA1Sum":"c3d48b897b75f91f0842bbcf40a9ac335bb932f8","SHA256Sum":"57e0e4256cef61ec5c3c988d424cd146ab999d536b7b369cd5f9a5470470c10b","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2025"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:05:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.267.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"76eb83a73c664b0c9e93bdd8ff3b21d5"}]},{"ProductId":"63976963938d4f79be04f7b652abb966","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4329464","DateModified":"2025-01-10T13:04:18","FileList":["cp065054.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"MD5Sum":"7afcc1b111a1b5eaf11a45ca385ac920","Name":"cp065054.exe","Release":"2025-01-10T13:00:23","Revision":"I","SHA1Sum":"cd8ba02f7fde9144a8c63c0f6898d47bfb3bbf4f","SHA256Sum":"0fadfc39f282f857218491408b65ccdef15769b81c1ac0f20591273962baa217","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:18:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.<br />&nbsp;</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.<br />&nbsp;</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.<br />&nbsp;</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c35a12155a584e44b0c05562951dde53"}]},{"ProductId":"29456540dcc74eaf9f223e63cf50eff7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li><li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li><li>The new drive bootloader code will be activated after the next drive power cycle.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4512908","DateModified":"2025-05-14T04:47:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/CP066497.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-12.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066497.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066497.scexe"],"MD5Sum":"4db1856fe27630322c7da747fc39c6be","Name":"firmware-hdd-aef2a690c9-HPG5-12.1.x86_64.rpm","Release":"2025-05-14T09:35:27","Revision":"L","SHA1Sum":"15d8800c6be06f4abba153e4c45c8ea0730d6730","SHA256Sum":"5620c34809709ca681a3ad21eb6f6ec9dce705b6924c893b0f96591ab6f5a05d","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP040776.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T13:59:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6a76cd63c54044e0b983d1a765d11f88"}]},{"ProductId":"d7cf155e76584b1f8fb8e3c7c222c90d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6273263","DateModified":"2025-05-15T10:00:06","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/CP066541.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066541.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066541.scexe"],"MD5Sum":"25b63edb2b9aab63eaebb1de39c550d3","Name":"firmware-hdd-82894b9e0a-HPG1-13.1.x86_64.rpm","Release":"2025-05-15T14:48:06","Revision":"M","SHA1Sum":"bc6be9bf460dda524ea18518cb4af38babbc0dcc","SHA256Sum":"44f6c9292d075e9243526ffadb6cfe4208fca57a0006e8bf29bdf1747da50811","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041482.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWRTC ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:32:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7f127a30827c40f2bf459c13df58ebcb"}]},{"ProductId":"6cc89934ad1740b582b096e05315f04a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Corrective actions to fix potential background media scan issue.</li></ul><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6501771","DateModified":"2025-05-15T09:59:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/CP066543.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066543.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066543.scexe"],"MD5Sum":"3c8d934b4ced7a24480a320ffd352710","Name":"firmware-hdd-cfd7436fcc-HPD4-4.1.x86_64.rpm","Release":"2025-05-15T14:48:41","Revision":"D","SHA1Sum":"471d55c0dc9d64a99baf774805df2b7beb6a7b96","SHA256Sum":"307e3e915ead1e0c3d95107966c7a3bf50076c55eebdbc85a468a10b379ba14f","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041518.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWUDBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JWUDB","TargetGUID":"4d2340a5-3042-3431-3030-304a57554442","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:36:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c0d031c28dd24a87ac47ffc4f2879dd3"}]},{"ProductId":"d1014161143144dea5631e9b65f9f0d4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18080535","DateModified":"2025-03-07T11:20:52","FileList":["/CP065968_BUILD_4.data","/CP065968.vmexe64","/CP065968.vmfile","/CP065968_VMw.zip","/CP065968.xml","/payload.json","/CP065968_VMw.zip/index.xml","/CP065968_VMw.zip/vendor-index.xml","/CP065968_VMw.zip/metadata.zip","/CP065968_VMw.zip/vib20/CP065968/HPE_bootbank_CP065968_HPD5.4-1OEM.800.1.0.20613240.vib","/CP065968_VMw.zip/metadata.zip/vendor-index.xml","/CP065968_VMw.zip/metadata.zip/vmware.xml","/CP065968_VMw.zip/metadata.zip/vibs/CP065968-6188334408085004066.xml","/CP065968_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065968_HPD5.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ea0d80224586688cac2bce65ebbeb1c5","Name":"CP065968.zip","Release":"2025-03-07T11:20:05","Revision":"E","SHA1Sum":"5b2141952fa9f3a335a618f518214cb8e65f132f","SHA256Sum":"fcce195f2935b350e3ffb707b771bfa50b9f5659f2562cb68334fabf73068654","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065968","Version":"HPD5.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041560.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:37:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"236ab9557d1a40f590bd1a3fb3c0a893"}]},{"ProductId":"c02f997871554705a1c6e597965673df","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11656004","DateModified":"2025-04-18T08:00:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/CP066825.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/U37_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.50_2025_04_17-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066825.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066825.scexe"],"MD5Sum":"57643b54f337f662354cde59456aecef","Name":"firmware-system-u37-3.50_2025_04_17-1.1.x86_64.rpm","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"ed4b51625fee3e7b1348d367175c5e824216287e","SHA256Sum":"00f283bb7a33211f58ec736d9a92f4f6264d8ff3aa35b8aef255699f38be7e5c","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>RPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230k Gen10 (U37)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bc124d2779ba4d83baa4b4a092bd2859"}]},{"ProductId":"d9b51eadf7e440fc88f26963aec59690","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064851.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2633504","DateModified":"2025-02-10T08:02:16","FileList":["cp064851.compsig","cp064851.zip","cp065607.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"07011cecd839524d7802b263c359b263","Name":"cp065607.exe","Release":"2025-02-10T07:59:48","Revision":"B","SHA1Sum":"ea65fb501f953b93d96fa5993cbf5edb6801b61d","SHA256Sum":"5597f3bb75549a2a87eb57d7d918e64f51682ffbed12a0ec76e42e95b3d3f27b","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:56:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bffaa737741b41878092a3c32ffba815"}]},{"ProductId":"4106b2f5d7c1411c95e94d52dff63df7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3803184","DateModified":"2025-03-14T05:07:15","FileList":["cp065060.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGNTG6.rel","setup.dll"],"MD5Sum":"ccea14271d43818f4e596d8c8ee6a012","Name":"cp065060.exe","Release":"2025-03-14T05:01:41","Revision":"D","SHA1Sum":"3a6dc2767924bf2f12ffad552f54d1a2353a3f00","SHA256Sum":"f4ab9cd92b85518cf4d2c85779b23157bc721386f5a9774de97c2b07883e5a32","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:36:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"292651a9b46e48c4ba5741942314a6b9"}]},{"ProductId":"56422dc0cdb64171addc0c9909a7019a","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp065007.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.702"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9044448","DateModified":"2025-02-10T07:32:14","FileList":["cp065007.compsig","cp065007.zip","cp065597.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"7e10b9232eca24ec55476b1dd8b71582","Name":"cp065597.exe","Release":"2025-02-10T07:31:05","Revision":"B","SHA1Sum":"4f62b095873b09960391f86f3a023c74d56593bc","SHA256Sum":"301e95956fa4992755685d1dabf67f3adba4baead3539afef7fc4788c781839d","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.702"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:28:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d5e8290846824f9db5ef0276c59eb3e9"}]},{"ProductId":"d33174a587ab4b3ea4d5e4e22de786d1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000GWKGR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6405734","DateModified":"2025-05-14T08:47:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/CP066520.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066520.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066520.scexe"],"MD5Sum":"9b5e6dbb0bff83aef168108c49b1385c","Name":"firmware-hdd-7f2a26e6d0-HPG1-13.1.x86_64.rpm","Release":"2025-05-14T13:35:08","Revision":"M","SHA1Sum":"46900e8db030263e09b0b61587e97f3d273f1eb1","SHA256Sum":"e1645023d4df296a71b52716952cbebc65a343250570420572a9758c7022b7df","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP041521.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWKGRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000GWKGR","TargetGUID":"4d2340a5-3042-3630-3030-3047574b4752","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T06:42:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10.</p>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e758ba908a834c6394a32bd2a2b9fc34"}]},{"ProductId":"8f4fd902230c4076905c23b7ab80bfdf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2022で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1243536","DateModified":"2025-04-01T02:00:17","FileList":["cp065283.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"ec9d3b1f98e65c7768917fa9933977ec","Name":"cp065283.exe","Release":"2025-04-01T01:45:40","Revision":"B","SHA1Sum":"708694417fe39bfdcb715202c9687effbc225b04","SHA256Sum":"1bde06f00688df5fcf2bc565419f0937cb744267ee3a2eb7244ed6d0342b3a7d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40ea Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel i40eaドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel i40ea Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:06:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.165.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2afdacbb67de47c5b45bc737cb9d4aae"}]},{"ProductId":"a745e380a94147888b60792dcbb594a8","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33604036","DateModified":"2025-05-21T12:34:06","FileList":["A42_3.72_05_16_2025.signed.flash","A42_3.72_05_16_2025.xml","payload.json"],"MD5Sum":"79557b3c9b9b0aefb68e4fb21fa8ec5a","Name":"A42_3.72_05_16_2025.fwpkg","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"f5b03a16640424259c410e03db9d16ac41b26d4c","SHA256Sum":"bd044ef16bf07e6217c082706a154cf81a5731cfec319de62e6fe63185404085","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"2ff8dd25bd2c4e49aaaef28ceb88dcc0"}]},{"ProductId":"fe217a349ea5432eb992dea833e5cc7b","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージには、ESXi 8.0上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"17566366","DateModified":"2024-11-04T05:41:22","FileList":["/CP063146.vmexe64","/CP063146.vmfile","/CP063146.xml","/CP063146_VMw.zip","/payload.json","/README.txt","/CP063146_VMw.zip/index.xml","/CP063146_VMw.zip/vendor-index.xml","/CP063146_VMw.zip/metadata.zip","/CP063146_VMw.zip/vib20/CP063146/HPE_bootbank_CP063146_1.0.2-8.0.0.20613240.vib","/CP063146_VMw.zip/metadata.zip/vendor-index.xml","/CP063146_VMw.zip/metadata.zip/vmware.xml","/CP063146_VMw.zip/metadata.zip/vibs/CP063146--461032880889672727.xml","/CP063146_VMw.zip/metadata.zip/bulletins/Smart-Component-CP063146_1.0.2-8.0.0.20613240.xml"],"MD5Sum":"00314bc280f6b49c393cb682c9642bf3","Name":"CP063146.zip","Release":"2024-11-04T05:42:09","Revision":"","SHA1Sum":"03f051fe5768e142a7532338f31f0120bd6787a9","SHA256Sum":"ccb866171a8fb9118d922417b9e52e0463bbe46ed9552ae8d9a16195cdd3763b","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.1","VibList":[{"Name":"CP063146","Version":"1.0.2-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ(ESXi 8.0)"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-05T06:41:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>バージョン14.32.1010には、以下の新機能と変更が含まれます。</strong></p><ul><li>3つの新しいアサートフィルター(ヘルスバッファー、NVlog、FWトレース)が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ(rate_limitに接続し、そのレート制限を共有するレート制限要素)へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。有効にするには、PF_NUM_OF_VF_VALIDをtrueにし、PF_NUM_OF_VFをゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン14.32.1010で修正されました：</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul>","Lang":"cn"}],"Version":"1.0.0"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"cn"}],"Version":"1.0.1"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d3c13232dc0145eba7a616305103d5a9"}]},{"ProductId":"d05a1433339f497faa2734fb31c015eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3971136","DateModified":"2025-01-10T10:57:15","FileList":["cp065030.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08acHPG4.REL"],"MD5Sum":"d755db0c016f5e9e2914d1f0b5893748","Name":"cp065030.exe","Release":"2025-01-10T10:53:17","Revision":"C","SHA1Sum":"f2f5ba25f28dfcd315e6b720ecfa622040ad926e","SHA256Sum":"10d534e2aaef9bbbec8d2e2a52731b3fe9aece0d4f2307e809c244d04ae49ec2","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:21:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"69cbde52ac6c497191b3b8ddeae80484"}]},{"ProductId":"6e357a862ebf4f379b5f531a7eb46680","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10Plus_04.04.04.702.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.702"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8410368","DateModified":"2025-01-17T05:46:15","FileList":["payload.json","SPSGen10Plus_04.04.04.702.signed.bin","SPSGen10Plus_04.04.04.702.xml"],"MD5Sum":"e50401eeab15cedae85dbae52d54c11f","Name":"SPSGen10Plus_04.04.04.702.fwpkg","Release":"2025-01-17T05:43:26","Revision":"","SHA1Sum":"3dae792410e69972adf7977adbfbec28dcabd8fe","SHA256Sum":"59e688fe0dfcb5c2444edc45847f0b80965d51f9d558e163aa5e46b56bf9cece","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"0","Version":"04.04.04.702"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-10T06:09:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This version is in compliance with IPU.2024.1 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/22/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2023-35191. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>このバージョンは、IPU.2024.1ガイダンスに準拠しています。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services(SPS)ファームウェアには、Intel製品アップデート(IPU)バージョンIPU.2024.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPSは、システムROM 2.00（02/22/2024）と組み合わせる必要があります。<p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>Server Platform Servicesファームウェアのこのリビジョンは、CVE-2023-35191としてドキュメント化されているセキュリティ上の脆弱性を緩和します。この問題は、HPEサーバーに固有のものではありません。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>This version is in compliance with IPU.2024.1 guidance.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/22/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2023-35191. This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"04.04.04.603"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.04.04.702 (2.30_01_06_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.04.04.702"}],"SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"21a9d63886a74bd2b8f222218e178c46"}]},{"ProductId":"cf7cb50c769b4b00ab89aa81d9fac797","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br />&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFEおよびVO003840RWUFFドライブ</p><p><strong>リリースバージョンおよび/または日付：</strong><br />     HPD8<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD7<br /><br /><strong>前のファームウェアバージョン：</strong><br />     HPD7<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし<br /> </p><p><strong>機能強化/新しい機能：</strong></p><p>     なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"19027854","DateModified":"2025-03-06T05:40:36","FileList":["/CP065957_BUILD_5.data","/CP065957.vmexe64","/CP065957.vmfile","/CP065957_VMw.zip","/CP065957.xml","/payload.json","/CP065957_VMw.zip/index.xml","/CP065957_VMw.zip/vendor-index.xml","/CP065957_VMw.zip/metadata.zip","/CP065957_VMw.zip/vib20/CP065957/HPE_bootbank_CP065957_HPD8.5-1OEM.800.1.0.20613240.vib","/CP065957_VMw.zip/metadata.zip/vendor-index.xml","/CP065957_VMw.zip/metadata.zip/vmware.xml","/CP065957_VMw.zip/metadata.zip/vibs/CP065957-1607623874845420466.xml","/CP065957_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065957_HPD8.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"9181fd91585914c8d615c847ed1191a6","Name":"CP065957.zip","Release":"2025-03-06T05:39:47","Revision":"C","SHA1Sum":"ad98f982776e3c603f88c12a73b80dc3d16a7c51","SHA256Sum":"42f70bab19b837073efad03725fb725e210fe89b3a0cdc893442a510ac9ec3b1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP065957","Version":"HPD8.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041554.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:43:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fe40c9bdbd145d3bc4d739f464f1c54"}]},{"ProductId":"6847395ba4ef4b018475096e40729a70","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"},{"Lang":"cn","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"},{"Lang":"ja","Value":"VMware ESXi 9 Update 0 Mellanox mst driver for Mellanox devices"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"33093","DateModified":"2025-03-19T09:02:34","FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp066257.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"MD5Sum":"a2f1b309047483e90e11b2b580ebbe8f","Name":"cp066257.zip","Release":"2025-03-19T09:01:33","Revision":"","SHA1Sum":"044d3c4713c741ec8c17712e956f495c185f97ec","SHA256Sum":"82d6e7f70f1109ab25782f90a65439c727fe9c4d877a5cc59f6b1c2575b286fc","Size":"32KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"cn","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"ja","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"},{"Lang":"cn","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"},{"Lang":"ja","Value":"net-mst kernel module driver component for VMware ESXi 9 Update 0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"8020","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c8020","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"801F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c801f","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F4","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f4","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F2","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f2","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f3","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"22F5","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f5","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f1","Type":"pci","Ven":"15b3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"0221","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101315900221","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-17T09:48:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 9&nbsp;Update 0&nbsp;only.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.17"}],"SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"","Model":"HPE Apollo sx40 Server"},{"Family":"","Model":"HPE Apollo pc40 Server"},{"Family":"","Model":"HPE Apollo kl20 Server"},{"Family":"","Model":"HPE Apollo am35 Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"54ee325a61e84639be6b288cef1e89ee"}]},{"ProductId":"423cc31f15944616b9452d63683a53fd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD3"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD3"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD3"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19762758","DateModified":"2025-03-06T06:08:20","FileList":["/CP065962_BUILD_2.data","/CP065962.vmexe64","/CP065962.vmfile","/CP065962_VMw.zip","/CP065962.xml","/payload.json","/CP065962_VMw.zip/index.xml","/CP065962_VMw.zip/vendor-index.xml","/CP065962_VMw.zip/metadata.zip","/CP065962_VMw.zip/vib20/CP065962/HPE_bootbank_CP065962_HPD3.2-1OEM.800.1.0.20613240.vib","/CP065962_VMw.zip/metadata.zip/vendor-index.xml","/CP065962_VMw.zip/metadata.zip/vmware.xml","/CP065962_VMw.zip/metadata.zip/vibs/CP065962-3828144449314861785.xml","/CP065962_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065962_HPD3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"6ea2537121136f3d018582c9be151267","Name":"CP065962.zip","Release":"2025-03-06T06:07:36","Revision":"B","SHA1Sum":"525bc7847cb253315171a626b50db100770014c6","SHA256Sum":"68004633e2e29e37acda90de765413ab53f0db563a71d6fef63ccb92922defdf","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065962","Version":"HPD3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9,0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9,0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:11:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2a3d0186209540c38458e0ca34d601e8"}]},{"ProductId":"5aad4922b5f54198b1d9a8e400dcfdda","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built for SUSE LINUX Enterprise Server 15 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMを使用して、HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plus、およびMR416i-p、MR416i-o、MR216i-o、MR408i-o、MR216i-p、MR408i-p Gen11コントローラーを有効にする、64ビットSUSE Linux Enterprise Server 15用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"865523","DateModified":"2025-04-25T05:15:13","FileList":["./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"MD5Sum":"eb4f544c5009694a7118c247e04c48d8","Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp5-1.x86_64.rpm","Release":"2025-04-25T05:10:46","Revision":"B","SHA1Sum":"5fc4b2ed98e85765f07b6e44ba943cffdbae08fd","SHA256Sum":"bc0bb2e2af74221d3e8ebf72ab0c859bf4ffe2bc0041fa3a87b95f5b80bf8ca5","Size":"845KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.732.03.00"},{"Bytes":"954358","DateModified":"2025-04-25T05:21:12","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"MD5Sum":"69f059e434fa7d0c6bc1ee8f33c8d913","Name":"lsi-megaraid_sas-kmp-default-07.732.03.00_sles15sp6-1.x86_64.rpm","Release":"2025-04-25T05:10:46","Revision":"B","SHA1Sum":"334a0009e89a261967ab6cc4c311bb89767f34b8","SHA256Sum":"f8eaacab591ec4f933bfcf0d6540df327ee5d957ccf50819d7a3b7fe12a3224d","Size":"931KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.732.03.00"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To install the driver, type the following command:<br /># rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br /><br />To upgrade the driver, type the following command:<br /># rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br /><br />A REBOOT is required for your computer when the setup is complete.</p>"},{"Lang":"ja","Value":"<p>To install the driver, type the following command:<br /># rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br /><br />To upgrade the driver, type the following command:<br /># rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br /><br />A REBOOT is required for your computer when the setup is complete.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"LSI Logic Corporation"},{"Lang":"ja","Value":"LSI Logic Corporation"},{"Lang":"cn","Value":"LSI Logic Corporation"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 15"},{"Lang":"ja","Value":"HPE MR416i-p、MR216i-p、MR416i-a、MR216i-a Gen10 plusおよびMR416i-p、MR416i-o、MR216i-o、 MR408i-o、MR216i-p、MR408i-p Gen11コントローラードライバーfor 64ビットSUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-24T10:51:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Handle IOMMU restore at exit boot services</li><li>Support Ubuntu 24.04 LTS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>終了ブートサービスでIOMMUの復元を処理する</li><li>Ubuntu 24.04 LTSをサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Handle IOMMU restore at exit boot services</li><li>Support Ubuntu 24.04 LTS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"07.730.01.00"},{"ReleaseNotes":[{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>MR208e-p Gen12コントローラーのサポートを削除しました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"cn"}],"Version":"07.732.03.00"}],"SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"24b6b1f981844df785c055d4910ae5ed"}]},{"ProductId":"f56420e1793d48958fc061b802e973db","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200/EN 200G 1p OSFP Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_45_1200-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30085","Version":"28.45.1200"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"},{"Lang":"ja","Value":"NVIDIA HPE署名済みPLDMファームウェアパッケージ for HPE InfiniBand NDR200/Ethernet 200Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B22およびP45642-H22"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported NDR200 / 200 GbE cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるNDR200 / 200 GbEケーブルおよびトランシーバー：</strong></p><p> </p><p><strong>HCA対スイッチ：</strong></p><ul><li>P45698-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B24        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B25        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B26        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P45698-B23        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5mスプリッターダイレクトアタッチ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B21        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P50397-B22        HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5mスプリッターアクティブ銅線ケーブル    （HCA対スイッチ）</li><li>P49766-B21        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード3mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B22        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード5mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B23        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード10mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B24        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード15mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B25        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード20mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li><li>P49766-B26        HPE InfiniBand NDR200/Ethernet 8ファイバーMPO to 2x4ファイバーMPOマルチモード30mスプリッターケーブル（HCA側マルチモード光ファイバートランシーバー対スイッチ側マルチモード光ファイバートランシーバー）</li></ul><p><strong>HCA側トランシーバー：</strong></p><ul><li>P49764-B21        HPE InfiniBand NDR/Ethernet 1x400Gb OSFPマルチモード50m HCA側トランシーバー（HCAマルチモード光ファイバートランシーバー）</li></ul><p><br />注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported NDR200 / 200 GbE cables and transceivers:</strong></p><p>&nbsp;</p><p><strong>HCA to Switch:</strong></p><ul><li>P45698-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 2.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 3m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P45698-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 1.5m Splitter Direct Attach Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 4m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P50397-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet OSFP to 4xOSFP 5m Splitter Active Copper Cable&nbsp;&nbsp; &nbsp;(HCA to Switch)</li><li>P49766-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 3m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B22&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 5m Splitter Cable&nbsp; &nbsp; &nbsp; (HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B23&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 10m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B24&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 15m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B25&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 20m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li><li>P49766-B26&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR200/Ethernet 8 Fiber MPO to 2x4 Fiber MPO Multi-mode 30m Splitter Cable&nbsp;&nbsp; &nbsp;(HCA-side&nbsp;Multi-mode optical fiber transceiver to Switch-side&nbsp;Multi-mode optical fiber transceiver)</li></ul><p><strong>HCA side transceiver:</strong></p><ul><li>P49764-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE InfiniBand NDR/Ethernet 1x400Gb OSFP Multi-mode 50m HCA-side Transceiver&nbsp;&nbsp; &nbsp;(HCA Multi-mode optical fiber transceiver)</li></ul><p><br />Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"9046774","DateModified":"2025-06-10T11:08:15","FileList":["28_45_1200-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","28_45_1200-MCX75310AAS-HEAT_HPE2_Ax.pldm.xml","payload.json"],"MD5Sum":"04cb36d457ae3d76136cdabec0d1f1b4","Name":"28_45_1200-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","Release":"2025-06-10T11:05:56","Revision":"","SHA1Sum":"90ea9a463d41fe74613d12da115a269b29846e4c","SHA256Sum":"4f01c4583c42524dcf3f9bf51470c2797d68b2651e4ac50d34aef5f7e7fe23ef","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30085"],"TypeOfChange":"1","Version":"28.45.1200"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"},{"Lang":"ja","Value":"NVIDIAファームウェアパッケージ(FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1ポートOSFP PCIe5 x16 MCX75310AAS-HEATアダプター。HPE部品番号P45642-B22およびP45642-H22"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1021","SubDev":"0085","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30085","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-02T10:17:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.44.1036:</strong></p><ul><li>Increased the RX lossless buffer size to delay the transmission of Pause/PFC frames during NIC congestion.</li><li>Added support for SyncE at 1G link speed.</li><li>Added a new mechanism for allocations and deallocations flows to enhance parallelism.</li><li>When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Added support for a new synchronized flow, including a tool and driver, to perform a fwreset on setups with a PCIe switch configuration.</li><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added support for new MADs: PortRecoveryPolicyConfig and PortRecoveryPolicyCounters . During the PHY recovery process, the firmware core will indicate the &nbsp;port_logical_state as Active.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 28.44.1036:</strong></p><ul><li>Cable info semaphore deadlock.</li><li>Improper error handling for the TLV full list, which caused the TLV mechanism to hang.</li><li>The SPDM GET_CERTIFICATE operation did not support all certificate chain offsets and chunk sizes.</li><li>An issue in VDPA where destroying a virtq would cause a health buffer syndrome with ext_synd=0x8f33 if the virtq was created without an mkey or with unmanned and mapped mkeys during live migration.</li><li>The VDPA feature bits GUEST_TSO4 and GUEST_TSO6 were unexpectedly set by default, leading to traffic interruptions.</li><li>Enabling PCC NP and setting the link type to one port as IB and the other as Ethernet could cause an assert to appear in dmesg with ext_synd 0x8309.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン28.44.1036には、以下の新機能と変更が含まれます。</strong></p><ul><li>NIC輻輳時にPause/PFCフレームの送信を遅延させるために、RXロスレスバッファーサイズを増やしました。</li><li>1Gリンク速度でのSyncEのサポートが追加されました。</li><li>並列処理を強化するために、割り当てフローと割り当て解除フローの新しいメカニズムを追加しました。</li><li>マルチホスト展開を使用する場合、各ホストには固有のポートとPFが割り当てられ、独自のLAGを管理します。</li><li>PCIeスイッチ構成のセットアップでfwresetを実行するためのツールとドライバーを含む新しい同期フローのサポートが追加されました。</li><li>同じPF上の異なるVF間で統合PTPがサポートされるようになりました。</li><li>新しいMADのサポートが追加されました: PortRecoveryPolicyConfigおよび PortRecoveryPolicyCounters 。PHY回復プロセス中、ファームウェアコアはport_logical_stateをActiveとして示します。</li><li>新しいNV構成 (SM_DISABLE、デフォルト0) が追加されました。これを有効にすると、SMから発信されていないSMPトラフィックがブロックされます。</li><li>PFCCアクセスレジスターのパラメーターとしてケーブル長を設定する機能を追加しました。ケーブルの長さは、サイズ、Xoff、Xon しきい値などの RXロスレスバッファーパラメーターの計算に使用されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン28.44.1036で修正されました。</strong></p><ul><li>ケーブル情報セマフォのデッドロック。</li><li>TLV完全リストのエラー処理が不適切だったため、TLVメカニズムがハングしました。</li><li>SPDM GET_CERTIFICATE操作は、すべての証明書チェーンのオフセットとチャンクサイズをサポートしていませんでした。</li><li>VDPAにおける問題で、virtqがmkeyなしで作成された場合、またはライブマイグレーション中に人を介さずマッピングされたmkeyで作成された場合、virtqを破棄するとext_synd=0x8f33でヘルスバッファー症候群が発生します。</li><li>VDPA機能ビットGUEST_TSO4およびGUEST_TSO6が予期せずデフォルトで設定され、トラフィックの中断が発生しました。</li><li>PCC NPを有効にし、リンクタイプを1つのポートにIB、もう1つのポートにEthernetを設定すると、dmesgにext_synd 0x8309のアサートが表示される可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.44.1036:</strong></p><ul><li>Increased the RX lossless buffer size to delay the transmission of Pause/PFC frames during NIC congestion.</li><li>Added support for SyncE at 1G link speed.</li><li>Added a new mechanism for allocations and deallocations flows to enhance parallelism.</li><li>When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Added support for a new synchronized flow, including a tool and driver, to perform a fwreset on setups with a PCIe switch configuration.</li><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added support for new MADs: PortRecoveryPolicyConfig and PortRecoveryPolicyCounters . During the PHY recovery process, the firmware core will indicate the &nbsp;port_logical_state as Active.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 28.44.1036:</strong></p><ul><li>Cable info semaphore deadlock.</li><li>Improper error handling for the TLV full list, which caused the TLV mechanism to hang.</li><li>The SPDM GET_CERTIFICATE operation did not support all certificate chain offsets and chunk sizes.</li><li>An issue in VDPA where destroying a virtq would cause a health buffer syndrome with ext_synd=0x8f33 if the virtq was created without an mkey or with unmanned and mapped mkeys during live migration.</li><li>The VDPA feature bits GUEST_TSO4 and GUEST_TSO6 were unexpectedly set by default, leading to traffic interruptions.</li><li>Enabling PCC NP and setting the link type to one port as IB and the other as Ethernet could cause an assert to appear in dmesg with ext_synd 0x8309.</li></ul>","Lang":"cn"}],"Version":"28.44.1036"},{"ReleaseNotes":[{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>New features and changes included in version 28.45.1200:</strong></p><ul><li>Introduced a 1ms delay for SPDM responses.</li></ul>","Fixes":"<p><strong>The following fixes have been included&nbsp;in version 28.45.1200:</strong></p><ul><li>Fixed DC InfiniBand functionality.</li></ul>","Lang":"cn"}],"Version":"28.45.1200"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT_VPI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6c78946b9648457aa05fb443b115ce09"}]},{"ProductId":"66a1346762c14adc98a81649c4277c93","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19656591","DateModified":"2025-03-06T13:03:19","FileList":["/CP065972_BUILD_1.data","/CP065972.vmexe64","/CP065972.vmfile","/CP065972_VMw.zip","/CP065972.xml","/payload.json","/CP065972_VMw.zip/index.xml","/CP065972_VMw.zip/vendor-index.xml","/CP065972_VMw.zip/metadata.zip","/CP065972_VMw.zip/vib20/CP065972/HPE_bootbank_CP065972_HPG2.1-1OEM.800.1.0.20613240.vib","/CP065972_VMw.zip/metadata.zip/vendor-index.xml","/CP065972_VMw.zip/metadata.zip/vmware.xml","/CP065972_VMw.zip/metadata.zip/vibs/CP065972--1267489814980660359.xml","/CP065972_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065972_HPG2.1-1OEM.800.1.0.20613240.xml"],"MD5Sum":"59e437c70059497ebf354f7923ccbcb6","Name":"CP065972.zip","Release":"2025-03-06T13:02:26","Revision":"C","SHA1Sum":"113de87441890db536b1a21a21d3d5dc4669202b","SHA256Sum":"35dd272093847ba981cf07bfaef21d7e61e1e334d5c6b74d97b2ab9485772d4b","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG2","VibList":[{"Name":"CP065972","Version":"HPG2.1-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:45:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"34731ffbed904cd2b0f1fce85be60590"}]},{"ProductId":"0e268c49682a427da167d2f123ccafaf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWFVKおよびMB006000JWFVL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWFVK and MB006000JWFVL Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWFVK and MB006000JWFVL Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18135660","DateModified":"2025-03-06T13:42:59","FileList":["/CP065961_BUILD_2.data","/CP065961.vmexe64","/CP065961.vmfile","/CP065961_VMw.zip","/CP065961.xml","/payload.json","/CP065961_VMw.zip/index.xml","/CP065961_VMw.zip/vendor-index.xml","/CP065961_VMw.zip/metadata.zip","/CP065961_VMw.zip/vib20/CP065961/HPE_bootbank_CP065961_HPD4.2-1OEM.800.1.0.20613240.vib","/CP065961_VMw.zip/metadata.zip/vendor-index.xml","/CP065961_VMw.zip/metadata.zip/vmware.xml","/CP065961_VMw.zip/metadata.zip/vibs/CP065961--8220774013519912696.xml","/CP065961_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065961_HPD4.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c1c8463f7acc8cbac18105f7eef1a2ec","Name":"CP065961.zip","Release":"2025-03-06T13:42:10","Revision":"F","SHA1Sum":"e97eb4e8eeb7d7651d0ed4d3ce9ed40606d6209f","SHA256Sum":"e6875b57a2b20c6afc806499bd9ce83a65a60fbdab0172d8f4c7b0d6fc974bf0","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065961","Version":"HPD4.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041749.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB004000JWFVK and MB006000JWFVL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -MB004000JWFVKおよびMB006000JWFVLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JWFVK","TargetGUID":"4d2340a5-3042-3430-3030-304a5746564b","Type":"sas"},{"Id":"MB006000JWFVL","TargetGUID":"4d2340a5-3042-3630-3030-304a5746564c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:11:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB004000JWFVK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWFVL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2b24794bc5944b7380c4d0cd633563bd"}]},{"ProductId":"c5274a8d3e3e40d790c226da85bd84aa","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"18400976","DateModified":"2025-03-06T14:35:54","FileList":["/CP065970_BUILD_4.data","/CP065970.vmexe64","/CP065970.vmfile","/CP065970_VMw.zip","/CP065970.xml","/payload.json","/CP065970_VMw.zip/index.xml","/CP065970_VMw.zip/vendor-index.xml","/CP065970_VMw.zip/metadata.zip","/CP065970_VMw.zip/vib20/CP065970/HPE_bootbank_CP065970_HPG7.4-8.0.0.20613240.vib","/CP065970_VMw.zip/metadata.zip/vendor-index.xml","/CP065970_VMw.zip/metadata.zip/vmware.xml","/CP065970_VMw.zip/metadata.zip/vibs/CP065970-1680710732244043349.xml","/CP065970_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065970_HPG7.4-8.0.0.20613240.xml"],"MD5Sum":"ba1ed029a493c7db63e66fb9814b826f","Name":"CP065970.zip","Release":"2025-03-06T14:35:09","Revision":"D","SHA1Sum":"d2eb2c278f6486df0269bb49661e7c1500e4c44a","SHA256Sum":"ecbf6bfeb6278d052578be6ee27d6fa89990434ab1101cac024fa9c089959827","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7","VibList":[{"Name":"CP065970","Version":"HPG7.4-8.0.0.20613240"}]}],"Installation":{"Command":"CP040790.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWTSV、 VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:41:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9ca3dd9ecb244e43acb9e5fe9d0ec0cb"}]},{"ProductId":"3c5ca1f7884d46278989b90e474b83e1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4548960","DateModified":"2025-01-10T10:22:22","FileList":["cp065038.xml","cpqsetup.exe","HVLAeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"698b616937812d9e0b2e06169fed9dda","Name":"cp065038.exe","Release":"2025-01-10T10:17:00","Revision":"F","SHA1Sum":"c6b37e5b9c64a48b66f05002eaf7e7fb28ca0f29","SHA256Sum":"036775ae618287efbe68009d3dc6b132e2cb50d1b0c72d48d373c67eb8ba2964","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000JWKGN ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:40:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"21953a197a564d96a90ac765cb067606"}]},{"ProductId":"000bfbde35e84381b78976b2c1748662","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するIntel Ethernet NIC用のiavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1415688","DateModified":"2025-04-01T06:08:16","FileList":["cp065296.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"eeb655f17333b3be1891a93b69ab6a1b","Name":"cp065296.exe","Release":"2025-04-01T05:54:06","Revision":"C","SHA1Sum":"ab8667f825a7a9d23492d0cf1574d492f2af3695","SHA256Sum":"9e49fcd399520aa7865696a30acbf144a37352626688b8b96668ea10d714c816","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel iavfドライバーfor Windows Server 2022"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:47:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"1.14.203.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"59e38000703848e5945b59577afa4ed6"}]},{"ProductId":"c549eb5726da4e0ab54cbcdd6abecebd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1106892","DateModified":"2025-04-02T07:50:58","FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/7d9387a0a25e8ffec0792672cfcfadc3fdb56b","./usr/lib/.build-id/bc","./usr/lib/.build-id/bc/99d164c42343cb3286cf9b6d5f09829ef512b3","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"MD5Sum":"da0fb83ec4ceaef88d6542d29d44ee6e","Name":"kmod-bnxt_en-1.10.3-233.0.152.2.rhel9u4.x86_64.rpm","Release":"2025-04-02T07:38:56","Revision":"","SHA1Sum":"ee9156c844ceef975df9f73e840a3cf4594f0eae","SHA256Sum":"f161f5514a305237d2c6ee19c6e7df31f0f368fcdd73e85020f46b9386a56599","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-233.0.152.2"},{"Bytes":"1113470","DateModified":"2025-04-02T07:56:03","FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/a5","./usr/lib/.build-id/a5/57c3e7f3d24ab606e40bace8b548e9581d4bee","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/d645be152bf7c6ed2ca20ca856d20f787ded76","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"MD5Sum":"9e1e0c375a1a3416e2c99182f7db42b0","Name":"kmod-bnxt_en-1.10.3-233.0.152.2.rhel9u5.x86_64.rpm","Release":"2025-04-02T07:38:56","Revision":"","SHA1Sum":"586a0d97b2b082722a39ed52ffc3a30198a49845","SHA256Sum":"34e96c657c52a2efb9277cb65d0d11536ba53615971e6c90c82bd70580a69e40","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-233.0.152.2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待どおりにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to update the installation location for nicclilom to the correct path.</li><li>This product enhances functionality by querying DCB settings when the NETDEV_CHANGE event occurs.</li></ul>","Fixes":"<ul><li>This product has fixed the ETS validation issue to prevent traffic class (TC) starvation caused by incorrect bandwidth allocation.</li><li>This product fixes the issue where debugfs qp_info displays the UDP source port value incorrectly.</li><li>This product fixes the issue where the device fails to unregister from PTP during shutdown or suspend.</li><li>This product fixes the issue where IPv6 VXLAN decapsulation was not properly supported.</li><li>This product fixes the issue where out-of-sequence (OOS) packets were being dropped.</li><li>This product fixes the issue where flow priority levels 0&ndash;3 were not handled correctly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating a coredump summary.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、nicclilomのインストール場所を正しいパスにアップデートするように強化されています。</li><li>この製品は、NETDEV_CHANGEイベントが発生したときにDCB設定を照会することで機能を強化します。</li></ul>","Fixes":"<ul><li>この製品では、不正な帯域幅割り当てによるトラフィッククラス(TC)の枯渇を防ぐために、ETS検証の問題を修正しました。</li><li>この製品は、debugfs qp_infoがUDP送信元ポート値を正しく表示しない問題を修正します。</li><li>この製品は、シャットダウンまたはサスペンド中にデバイスがPTPから登録解除できない問題を修正します。</li><li>この製品は、IPv6 VXLANカプセル化解除が適切にサポートされていなかった問題を修正しました。</li><li>この製品は、順序外(OOS)パケットがドロップされる問題を修正します。</li><li>この製品は、フロー優先度レベル0 ～ 3が正しく処理されない問題を修正します。</li><li>この製品は、コアダンプサマリーを生成するときにコアダンプファイルデコーダーがクラッシュする問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to update the installation location for nicclilom to the correct path.</li><li>This product enhances functionality by querying DCB settings when the NETDEV_CHANGE event occurs.</li></ul>","Fixes":"<ul><li>This product has fixed the ETS validation issue to prevent traffic class (TC) starvation caused by incorrect bandwidth allocation.</li><li>This product fixes the issue where debugfs qp_info displays the UDP source port value incorrectly.</li><li>This product fixes the issue where the device fails to unregister from PTP during shutdown or suspend.</li><li>This product fixes the issue where IPv6 VXLAN decapsulation was not properly supported.</li><li>This product fixes the issue where out-of-sequence (OOS) packets were being dropped.</li><li>This product fixes the issue where flow priority levels 0&ndash;3 were not handled correctly.</li><li>This product fixes the issue where the coredump file decoder crashes when generating a coredump summary.</li></ul>","Lang":"cn"}],"Version":"1.10.3-232.0.155.5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.10.3-233.0.152.2"}],"SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6a072d3d9c654382b1076084b956d04a"}]},{"ProductId":"84e7c2b1f88e4ba3ad8fe3ec63fe5a60","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"27172890","DateModified":"2025-03-05T01:10:27","FileList":["/CP064939.vmexe64","/CP064939.vmfile","/CP064939.xml","/CP064939_VMw.zip","/payload.json","/README.txt","/CP064939_VMw.zip/index.xml","/CP064939_VMw.zip/vendor-index.xml","/CP064939_VMw.zip/metadata.zip","/CP064939_VMw.zip/vib20/CP064939/HPE_bootbank_CP064939_1.0.2-1OEM.900.0.24580437.vib","/CP064939_VMw.zip/metadata.zip/vendor-index.xml","/CP064939_VMw.zip/metadata.zip/vmware.xml","/CP064939_VMw.zip/metadata.zip/vibs/CP064939-3183264575836906926.xml","/CP064939_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064939_1.0.2-1OEM.900.0.24580437.xml"],"MD5Sum":"4357ecf6f3e78a9f7d770d3ba7a90879","Name":"CP064939.zip","Release":"2025-03-05T01:17:08","Revision":"","SHA1Sum":"90aa1bc5c2b79e302ae6bae116bcf529ff5de9dc","SHA256Sum":"9e65b0850e5e8bdbe787d1715a4a5aded2644ffe76473044b7940a13950693ce","Size":"25MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.0","VibList":[{"Name":"CP064939","Version":"1.0.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox Ethernet only adapters"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox Ethernet only adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-07T09:58:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3b1c718ef1b648f69d52e15b0a96a050"}]},{"ProductId":"2433baff8f4443ed8ddae6e9a115bc4d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1075752","DateModified":"2025-04-01T03:44:16","FileList":["cp065269.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"a71337a265adc011d85831fc10809fc9","Name":"cp065269.exe","Release":"2025-04-01T03:30:38","Revision":"C","SHA1Sum":"b38e7abb28e724d613f1c2f8e6020eb2290328aa","SHA256Sum":"def5de0a42f3e31a50001b30815cb7477bd30e63e9fbe19318600ff31a515466","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2022"},{"Lang":"ja","Value":"Intel i350ドライバー for Windows Server 2022"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:32:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"14.0.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"14.0.5.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"76402b75677d4c258cfc388969d9a716"}]},{"ProductId":"630e644160fa42ef980745ef1697fa39","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Improves performance in certain file systems and implements fixes for several of the previous firmware&rsquo;s shortcomings.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li><li>Several maintenance items are included in this firmware revision that reduce the probability of hangs.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6019843","DateModified":"2025-05-15T10:59:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/CP066527.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/TAMG09scHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066527.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066527.scexe"],"MD5Sum":"51b73d8a45bf7e225bbe96a70da4a5bd","Name":"firmware-hdd-87b796d9ae-HPD4-4.1.x86_64.rpm","Release":"2025-05-15T15:49:09","Revision":"D","SHA1Sum":"0c301e3edc8c53a48b03398fddab6caaba6040c9","SHA256Sum":"c290337ebf8bae815a2b90457f0bea19bb7e69fff6a30f75de7ccc455485c47e","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:38:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1ba9c1ea08be45cc8bb840bf7a2d0da9"}]},{"ProductId":"3ab4de78da484144892d6ddcd8fd9b97","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe-kmp-default) to (igb-ixgbe-default). Now we revert this change from (ixgbe-kmp-default) to (<strong>hp</strong>-ixgbe-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbe-kmp-default and ixgbe-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbe-kmp-default and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません <br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbe-kmp-default）から（igb-ixgbe-default）に変更されました。この変更を（ixgbe-kmp-default）から（<strong>hp</strong>-ixgbe-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-ixgbe-kmp-defaultとixgbe-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbe-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished&nbsp;<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe-kmp-default) to (igb-ixgbe-default). Now we revert this change from (ixgbe-kmp-default) to (<strong>hp</strong>-ixgbe-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbe-kmp-default and ixgbe-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbe-kmp-default-5.19.6_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbe-kmp-default and then install the updated RPM.</p>"}],"Files":[{"Bytes":"372931","DateModified":"2025-04-01T07:53:11","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"MD5Sum":"eba9e3ef21a27816b5d787a60ec9684f","Name":"hp-ixgbe-kmp-default-5.22.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T07:13:08","Revision":"","SHA1Sum":"90ab395bbc5bce14828d7e229a32560294a030e2","SHA256Sum":"662c3057a19a866b2f574fda341d8eef92a3a0328778dde34f8077d272655628","Size":"364KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"5.22.25-1"},{"Bytes":"325863","DateModified":"2025-04-01T07:48:07","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/hp-ixgbe","./lib/modules/5.14.21-150500.53-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"MD5Sum":"e7ef9b3f3524551bdc56e86f75c32fa8","Name":"hp-ixgbe-kmp-default-5.22.25_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T07:13:08","Revision":"","SHA1Sum":"72c7c0059c19b3add51b9bd4c3b0805a5b124e10","SHA256Sum":"516d1523ea7804b4028c29b7c3059420d819e7e118eb5ba82e3c78b726433a23","Size":"318KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"5.22.25-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:02:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"cn"}],"Version":"5.21.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"5.22.25-1"}],"SWKeys":[{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4becb267edcd49a3820aa03003cc811a"}]},{"ProductId":"d65fb45f0327449eb7763d2d9cb7bf3e","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"28490039","DateModified":"2025-05-15T06:50:08","FileList":["/CP066430_BUILD_10.data","/CP066430.vmcfg","/CP066430.vmexe64","/CP066430.vmfile","/CP066430_VMw.zip","/CP066430.xml","/payload.json","/CP066430_VMw.zip/index.xml","/CP066430_VMw.zip/vendor-index.xml","/CP066430_VMw.zip/metadata.zip","/CP066430_VMw.zip/vib20/CP066430/HPE_bootbank_CP066430_0130.10-8.0.0.20613240.vib","/CP066430_VMw.zip/metadata.zip/vendor-index.xml","/CP066430_VMw.zip/metadata.zip/vmware.xml","/CP066430_VMw.zip/metadata.zip/vibs/CP066430-992899833893569282.xml","/CP066430_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066430_0130.10-8.0.0.20613240.xml"],"MD5Sum":"20d39479e2fd1965d5908385d3fc5e44","Name":"CP066430.zip","Release":"2025-05-15T06:46:43","Revision":"G","SHA1Sum":"61549967a9445fdf89a98c5ca33da64a98bc19ac","SHA256Sum":"0951a082087e6eb3930ce3dd8ff24d9c90399e25bec56c3b1ca220be0ef6c462","Size":"27MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130","VibList":[{"Name":"CP066430","Version":"0130.10-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D8000 -v 0130 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff -l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D8000 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:16:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v266657/20-D8000-Gen10RN0130H_ED9.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"acde336247b04c929931baaca6b17520"}]},{"ProductId":"fbb53cf22a594dbb99b8c7f89e562124","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p71_NCSIwPLDMoMCTP_8002003D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>8002003D</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in&nbsp;<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター</td><td>8002003D</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td><td>8002003D</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in&nbsp;<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524750","DateModified":"2025-04-01T02:54:20","FileList":["HPE_E810_XXVDA2_SD_OCP_4p71_NCSIwPLDMoMCTP_8002003D.HPb","HPE_E810_XXVDA2_SD_OCP_4p71_NCSIwPLDMoMCTP_8002003D.xml","payload.json"],"MD5Sum":"b55b98f117244012d5e13cb7d7fc087c","Name":"HPE_E810_XXVDA2_SD_OCP_4p71_NCSIwPLDMoMCTP_8002003D.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"72b79fb90e758b4eb070d943bc5c3e8d3e291324","SHA256Sum":"1268aeddb2b649afb6559403b9b7b27d4f03154f421f1da8803c59c52cf60754","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:37:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a0dfe3fe6cd2438a867fcd6b1bbf7f86"}]},{"ProductId":"865064fe88324b7ea65c940d300f10de","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000JXMTH and MB020000JXMTP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000JXMTH and MB020000JXMTP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20315487","DateModified":"2025-03-06T13:25:52","FileList":["/CP065976_BUILD_4.data","/CP065976.vmexe64","/CP065976.vmfile","/CP065976_VMw.zip","/CP065976.xml","/payload.json","/CP065976_VMw.zip/index.xml","/CP065976_VMw.zip/vendor-index.xml","/CP065976_VMw.zip/metadata.zip","/CP065976_VMw.zip/vib20/CP065976/HPE_bootbank_CP065976_HPD3.4-1OEM.800.1.0.20613240.vib","/CP065976_VMw.zip/metadata.zip/vendor-index.xml","/CP065976_VMw.zip/metadata.zip/vmware.xml","/CP065976_VMw.zip/metadata.zip/vibs/CP065976-8794686904810807406.xml","/CP065976_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065976_HPD3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"40ce2f39bf93879fda6b19cce64c8e9d","Name":"CP065976.zip","Release":"2025-03-06T13:25:09","Revision":"B","SHA1Sum":"53f9bbde5fce39eb4911e0a02fccaa7f8301ab5a","SHA256Sum":"43ef7c98bc16e5528361ebb1e14577c22a86625cc79b67bd9ee4a93c38dffa01","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065976","Version":"HPD3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"},{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:01:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2e40f73a1fb54c0abb55aa2da3f59574"}]},{"ProductId":"f5b93810cc2347bb802707c26e414376","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_44_1036-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.44.1036"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"Mellanox HPE署名済みPLDMファームウェアパッケージfor MCX623105AS-VDAT Ethernet 200Gb 1ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.44.1036</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.44.1036</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE&nbsp;(P10180-B21)</td><td>22.44.1036</td><td>MT_0000000435</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"7684597","DateModified":"2025-04-11T07:18:17","FileList":["22_44_1036-MCX623105AS-VDA_Ax.pldm.signed","22_44_1036-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"MD5Sum":"c4d3603fd58e32ee7fcab8ae33fd6773","Name":"22_44_1036-MCX623105AS-VDA_Ax.pldm.fwpkg","Release":"2025-04-11T07:15:47","Revision":"","SHA1Sum":"8c95c2f927897786195727173140f0878199a4b3","SHA256Sum":"0a788e867096534a97d46d78d85c1107f5bab55fff09533e8ef8450351801b9a","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"TypeOfChange":"1","Version":"22.44.1036"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1ポートQSFP56アダプターfor HPE"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-17T09:10:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry .</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action reduces the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li><li>Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Increased the maximum number of supported &quot;ARC-IN&quot; from 1 to 8 and &quot;ARCOUT&quot; from 3 to 8 for the dynamic flex parser.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>An upgrade issue that required firmware v22.36.1010 as an intermediate version when upgrading the firmware from v22.33.0428 or below to versions above 22.36.1010.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"en"},{"Enhancements":"<p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン22.43.1014には、以下の新機能と変更が含まれます。</strong></p><ul><li>VF移行中にCQドアベルが失われた場合に備えて回復手順を追加しました。</li><li>eSwitchマネージャーごとに選択されたすべての機能でエラーCQEイベントを示すオプションが追加されました。この表示は、エラーに関する関連情報 (シンドローム、function_id、タイムスタンプ、QP番号など) を含む新しいWQEとして定義されます。この機能は、新しい一般オブジェクトであるRDMA-Telemetryオブジェクトを使用して構成され、次の新しいキャップに依存します。</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_typesおよびHCA_CAP.rdma_telemetry。</p><ul><li>拡張カーネルロックダウン権限セット。新しいHCA機能ビットマスクフィールドtool_partial_capを使用して、ツール (権限TOOLS_RESORCES) によって次のサブ操作を呼び出すことができるようになりました。</li></ul><p style=\"margin-left:80px\">5つのサブ操作は次のとおりです。</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAPと他の機能</li><li>QUERY_VUIDと直接データ</li><li>QUERY_ROCE_ADDRESSと他のvport</li><li>SET_HCA_CAPと他の機能</li><li>POSTPONE_CONNECTED_QP_TIMEOUTと他のvport</li></ul><p style=\"margin-left:80px\">新しく追加された機能は次のとおりです。</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>ステアリングアクション (STC) の\"Jump To Flow\"テーブルパラメーターに'table_type_valid'および'table_type'フィールドが追加され、ユーザーがNIC_TXからFDB_TXにジャンプしてACLテーブルをバイパスできるようになりました。</li><li>さまざまなユースケースでNICドメインをバイパスすることでホップ削減を可能にしました。このようなアクションにより、大量のフローとデバイスを処理するためのホップ数が削減されます (PPSが向上します)。この新しい機能を有効にするために、テーブルのRX側にジャンプできるようにする新しいSTCアクションタイプ\"JUMP_TO_FDB_RX\"が追加されました。</li><li>LAGにグループ化された複数のE-SwitchにわたるQoSスケジューリングのサポートが追加されました。ある物理機能のVPortメンバーを、別の物理機能からのレートグループに追加することができ、グループのレート制限はそれらのVPortメンバーにも適用されます。</li><li>動的フレックスパーサーでサポートされる\"ARC-IN\"の最大数を1から8に、\"ARC-OUT\"の最大数を3から8に増やしました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン22.43.1014で修正されました：</strong></p><ul><li>create_sqが無効なmboxを使用した場合、セットアップがクラッシュする。これで、無効なmboxが有効なDBに置き換えられました。</li><li>ファームウェアをv22.33.0428以下から22.36.1010以上のバージョンにアップグレードするときに、中間バージョンとしてファームウェアv22.36.1010が必要になるアップグレードの問題。</li><li>FACTORYのデフォルトのNV構成値のクエリを修正しました。ファームウェアは常に適用される「次」値を返しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.43.1014:</strong></p><ul><li>Added a recovery step in case of CQ doorbell getting lost during VF migration.</li><li>Added the option to indicate an error CQE event on every selected function per eSwitch manager. This indication is defined as a new WQE including the relevant information about the error (such as: syndrome, function_id, timestamp, QPs num etc.). The feature is configured using a new general object: RDMA-Telemetry object, and depends on the following new caps:</li></ul><p style=\"margin-left:80px\">HCA_CAP.rdma_telemetry_notification_types and HCA_CAP.rdma_telemetry .</p><ul><li>Extended kernel lockdown permission set. The following sub-operations can now be called by tools (permission TOOLS_RESORCES) using new HCA capability bitmask field: tool_partial_cap.</li></ul><p style=\"margin-left:80px\">The 5 sub-operations are:</p><ul style=\"margin-left:80px\"><li>QUERY_HCA_CAP with other function</li><li>QUERY_VUID with direct data</li><li>QUERY_ROCE_ADDRESS with other vport</li><li>SET_HCA_CAP with other function</li><li>POSTPONE_CONNECTED_QP_TIMEOUT with other vport</li></ul><p style=\"margin-left:80px\">The new added caps are:</p><ul style=\"margin-left:80px\"><li>tool_partial_cap.postpone_conn_qp_timeout_other_vport,</li><li>tool_partial_cap.set_hca_cap_other_func</li><li>tool_partial_cap.query_roce_addr_other_vport</li><li>tool_partial_cap.query_vuid_direct_data</li><li>tool_partial_cap.query_hca_cap_other_func</li></ul><ul><li>Added &#39;table_type_valid&#39; and &#39;table_type&#39; fields to the steering action (STC) &quot;Jump To Flow&quot; table parameters to enable the user to jump from NIC_TX to FDB_TX and bypass the ACL table.</li><li>Enabled hop reduction by bypassing NIC domain in various use cases. Such action reduces the number of hops (improves PPS) to deal with mass number of flows and devices. To enable this new capability, a new STC action type &quot;JUMP_TO_FDB_RX&quot; was added to allow jumping into the RX side of a table.</li><li>Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Increased the maximum number of supported &quot;ARC-IN&quot; from 1 to 8 and &quot;ARCOUT&quot; from 3 to 8 for the dynamic flex parser.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.43.1014:</strong></p><ul><li>Setup crash would occur when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB.</li><li>An upgrade issue that required firmware v22.36.1010 as an intermediate version when upgrading the firmware from v22.33.0428 or below to versions above 22.36.1010.</li><li>Fixed the query for FACTORY default NV configuration values. The firmware always returned the &quot;next&quot; value to be applied.</li></ul>","Lang":"cn"}],"Version":"22.43.1014"},{"ReleaseNotes":[{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"en"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 22.44.1036:</strong></p><ul><li>Unified PTP is now supported across different VFs on the same PF.</li><li>Added a new NV config (SM_DISABLE, default 0) which, when enabled, blocks SMP traffic that does not originate from the SM.</li><li>Added the ability to set cable length as a parameter in the PFCC access register. The cable length is used in the calculation of RX lossless buffer parameters, including size, Xoff, and Xon thresholds.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 22.44.1036:</strong></p><ul><li>Traffic would&nbsp;halt and recovery would be prevented when the emulation doorbell malfunctioned.</li></ul>","Lang":"cn"}],"Version":"22.44.1036"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"ca0efb5f527a4effad0254cffd6d944d"}]},{"ProductId":"a294766010e4496a9a5cf2711f22fa84","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"},{"Lang":"ja","Value":"BIOS - ????ROM"},{"Lang":"cn","Value":"BIOS - ?? ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33601479","DateModified":"2025-06-16T08:22:18","FileList":["payload.json","U47_2.42_06_13_2025.signed.flash","U47_2.42_06_13_2025.xml"],"MD5Sum":"24cefa276d3e6665d65200d76abaea3f","Name":"U47_2.42_06_13_2025.fwpkg","Release":"2025-06-16T08:19:03","Revision":"","SHA1Sum":"e4e57d53a4858423b1eb8bd6e1eb104a8c583cbd","SHA256Sum":"27ceb4bd469a96c5b0ee2e1fcd785019ebaa75e4fd8857ace2791d5208df82e1","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:08:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"91ee6f429bbf4a57b913d12f6024346e"}]},{"ProductId":"0e95d953f6c341e2ab45544cad6adaa1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11517544","DateModified":"2025-04-18T11:34:54","FileList":["cp066819.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_3.50_04_17_2025.signed.flash"],"MD5Sum":"965cc59b57df0cffb64cecefb488279b","Name":"cp066819.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"0716c49508043a0372ee6f38555832f424b30b5e","SHA256Sum":"a7b651b5d732e70d64304929dd529e9c7cb013eb0ce3253a501cb7a625b9d705","Size":"10MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> </p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML110 Gen10 (U33)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"f5fe2372ea3b42058cb56673a96b5674"}]},{"ProductId":"923bb6bba3254a6d80257c1bf056f39d","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM6 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM6_1.04_C.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901506000000","Version":"1.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM6 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM6ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM6 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"130733","DateModified":"2025-02-14T06:45:15","FileList":["HPE_UBM6_1.04_C.HPb","HPE_UBM6_1.04_C.xml","payload.json"],"MD5Sum":"f3b698458d2d40ebab31191b8eb67e6f","Name":"HPE_UBM6_1.04_C.fwpkg","Release":"2025-02-14T06:42:22","Revision":"C","SHA1Sum":"5cb04d82ad926b9fe3dd3ba8ef20b276c1e8aba0","SHA256Sum":"7a3ba98289b4099a34f1039390b6d09effb050ce8e4310f30f77b170e03dad15","Size":"127KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901506000000"],"TypeOfChange":"1","Version":"1.04"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage"},{"Lang":"ja","Value":"ファームウェアパッケージ - UBM6バックプレーンPIC PLDMファームウェアfor Gen10/Gen10P/Gen11/Gen12サーバーの使用"},{"Lang":"cn","Value":"Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901506000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-14T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support RL300 Gen11 server and Gen12 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>RL300 Gen11サーバーおよびGen12サーバーをサポート</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support RL300 Gen11 server and Gen12 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.04"},{"ReleaseNotes":[{"Enhancements":"<p>Support SY480 Gen12 server.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support SY480 Gen12 server.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support SY480 Gen12 server.</p>","Fixes":"","Lang":"cn"}],"Version":"1.04"}],"SWKeys":[{"Name":"UBM6PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"96ab565fa9d9472197e8151242b94100"}]},{"ProductId":"3f4d9eceae63421389745abdf06f001a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6264918","DateModified":"2025-06-16T05:54:14","FileList":["20_43_2566-MCX653436A-HDA_HPE_Ax.pldm.signed","20_43_2566-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"915cbc1d2dd2e4834d4a9ee710bd72e3","Name":"20_43_2566-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:51:36","Revision":"","SHA1Sum":"67b044b99362a7c49edeb71e57b108fa050fba10","SHA256Sum":"8b7b46322dc3132953a98692bdc19da4a19272577542b4bcae060350670d98bf","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900348"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T07:21:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"18b949b5ca454f8ca429e432693e3356"}]},{"ProductId":"3b83490f55194800be58721a957dd6a1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000GWTFEおよびMB014000GWTFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3292072","DateModified":"2025-01-11T03:25:14","FileList":["cp065069.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG07abHPG8.REL"],"MD5Sum":"4626ec29f9dc7e87182368baaaff1d3a","Name":"cp065069.exe","Release":"2025-01-11T03:21:29","Revision":"D","SHA1Sum":"afe37e5006a7a06bfbcc8ef5825be6d26577fe7f","SHA256Sum":"46a17cac9a6fb9591bb3d68d1c590807095f22176373ff6b7147c7a8ee4c1290","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- MB012000GWTFEおよびMB014000GWTFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000GWTFF","TargetGUID":"4d2340a5-3042-3431-3030-304757544646","Type":"sata"},{"Id":"MB012000GWTFE","TargetGUID":"4d2340a5-3042-3231-3030-304757544645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:35:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB012000GWTFE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWTFF","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1a83dd24e90b43148e98ce2733b64821"}]},{"ProductId":"75dd01ca72594b0686b5c281ad30ac2a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2302-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2302"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4506-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 9.0"},{"Lang":"ja","Value":"このパッケージは、VMware ESXi 9.0上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td><td>12.28.2302</td><td>HP_2180110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td><td>12.28.2302</td><td>HP_2190110032</td></tr><tr><td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td><td>16.35.4506</td><td>HPE0000000009</td></tr><tr><td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td><td>16.35.4506</td><td>HPE0000000022</td></tr></tbody></table>"}],"Files":[{"Bytes":"25561507","DateModified":"2025-04-23T09:21:05","FileList":["/CP066779.vmexe64","/CP066779.vmfile","/CP066779.xml","/CP066779_VMw.zip","/payload.json","/CP066779_VMw.zip/index.xml","/CP066779_VMw.zip/vendor-index.xml","/CP066779_VMw.zip/metadata.zip","/CP066779_VMw.zip/vib20/CP066779/HPE_bootbank_CP066779_1.0.2-1OEM.900.0.24580437.vib","/CP066779_VMw.zip/metadata.zip/vendor-index.xml","/CP066779_VMw.zip/metadata.zip/vmware.xml","/CP066779_VMw.zip/metadata.zip/vibs/CP066779-5894610824560407061.xml","/CP066779_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066779_1.0.2-1OEM.900.0.24580437.xml"],"MD5Sum":"66344a772646b9aa26f8eac6761960b1","Name":"CP066779.zip","Release":"2025-04-23T09:22:28","Revision":"","SHA1Sum":"25043f59398f99a7d494b8ef5db6e0f75e61a376","SHA256Sum":"9e769365e5f2d13c291b0d670e1d6742dc58eb96285a3784b4a499426a2e2c8b","Size":"24MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.1","VibList":[{"Name":"CP066779","Version":"1.0.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記</strong>：SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションにアダプターの正確な名前が表示されません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください： </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します  <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。<br /> </p><p><strong>注記：</strong>CX5ネットワークアダプターファームウェアを16.21.1xxxまたは16.22.1xxx（またはそれ以前）から16.26.1xxx（またはそれ以降）にアップグレードするには、中間ファームウェアバージョンとして16.23.1xxxまたは16.24.1xxxまたは16.25.1xxxを使用してください。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p>&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.<br />&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.0"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(ESXi 9.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 9.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T12:26:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1ポート840QSFP28アダプター)</li><li>825111-B21(HPE InfiniBand EDR/Ethernet 100Gb 2ポート840QSFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>879482-B21(HPE InfiniBand FDR/Ethernet 40/50Gb 2ポート547FLR-QSFPアダプター)</li><li>872726-B21（HPE InfiniBand EDR/Ethernet 100Gb 2ポート 841QSFP28アダプター）</li></ul><p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p><strong>バージョン12.28.2302には新機能の追加も変更もありません。</strong></p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302に追加された新しい修正はありません。</strong></p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li><li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)</li></ul><p><strong>Firmware for the following devices has been&nbsp;updated to 16.35.4506:</strong></p><ul><li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li><li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li></ul><p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No new Features and changes included in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new fixes have been added in version 12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><p>&nbsp;</p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.1"}],"SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"df2562496c8f4269a1d39aa8f6df8cf1"}]},{"ProductId":"87a7eb56c25b4c4c98ceb5ea24664524","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-p_Gen10P_52.32.3-6118_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.32.3-6118"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR216i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7507596","DateModified":"2025-06-13T15:48:13","FileList":["HPE_MR216i-p_Gen10P_52.32.3-6118_A.HPb","HPE_MR216i-p_Gen10P_52.32.3-6118_A.xml","payload.json"],"MD5Sum":"03689c5f85acbd6e52e66150be4ff069","Name":"HPE_MR216i-p_Gen10P_52.32.3-6118_A.fwpkg","Release":"2025-06-13T15:45:01","Revision":"","SHA1Sum":"5636a2143c403a7d9ed8158cef989e978e286e30","SHA256Sum":"f1b7b1ad6d8e0b9468384b0bfaeb92d8760fcd8dfd70cfe1e88736209fffcd51","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.32.3-6118"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller "},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR216i-p Gen10 Plusトライモードコントローラー "},{"Lang":"cn","Value":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The&nbsp;algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and are not applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfishデバイス有効化機能強化: Redfish暗号化のサポートを追加(POST&PATCH）</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">注記: MRコントローラーはSEDのみをサポートします。したがって、Volume[EncryptionTypes]はPOST(作成)またはPATCH(アップデート)中に書き込みできません。それに応じて、次の注釈は入力されません。</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o 注記:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted]は、適格なボリュームに対してオプション「true」を指定してのみ発行できます。MRファームウェアではセキュアボリュームを非セキュアボリュームに変更できないため、オプション 'false' を指定した PATCH Volume[Encrypted] は失敗します。</li><li>POST (作成) 中に、RAIDType=Noneのボリュームを作成する場合、「暗号化」オプションは使用できません。これは、MRが1ステップで安全なJBODを作成することをサポートしていないためです。JBODを作成した後、PATCH Volume [Encrypted = true] を発行して安全なJBODを作成できます。</li><li>ユーザーがEKMへの変更を要求するたびに、UEFIドライバー経由でキーを取得するために再起動が必須になります。</li></ul><ul><li>MR408i-pのサポートを追加</li><li>UBM10バックプレーンのサポートを追加しました</li><li>FWアップデート中に中断が発生した場合、UBMコントローラーがブートローダ状態にあるときに、UBM バックプレーンFWバージョン表示とFWアップデートをサポートします。</li><li>マップ解除可能な論理ドライブ用の NVMe SSDをサポートします。SATA SSDは、マップ解除可能な論理ドライブではサポートされないことに注意してください。</li><li>NANDフラッシュリフレッシュの改善</li></ul><p style=\"margin-left:80px\">o 指定された日数後に「System reset required」というイベントを投稿するアルゴリズムが削除されました。更新は同じ指定された時間後に行われ、新しいイベントが以下のように入力されます。</p><ul><li style=\"margin-left: 80px;\">NANDフラッシュのリフレッシュを開始する前に: 「NAND refresh in progress:changing WB Logical Drives to WT」</li><li style=\"margin-left: 80px;\">NAND フラッシュのリフレッシュが完了したら、「NAND refresh complete:changing WT virtual disks to WB」</li><li style=\"margin-left: 80px;\">上記の動作はMR400コントローラーにのみ適用され、MR200コントローラーには適用されません。</li><li>RAID1整合性チェックイベント文字列の変更</li></ul><p style=\"margin-left:80px\">o イベント文字列が「Consistency Check found inconsistent parity on LD <Ld Id> at strip <Strip Number>」から「Consistency Check found inconsistency on LD <Ld Id> at strip <Strip Number>」に変更されました。</p><ul><li>シャットダウン時に構成されたドライブのスピンダウンを制御するための新しいコントローラープロパティ「Spin Down Drives At Shutdown」をサポートします。</li><li>SCSI NVMe変換レイヤー仕様バージョン1.14のサポート</li></ul>","Fixes":"<ul><li>修正 a00143232en_us: HPE MR Gen11 コントローラー - AMD EPYC 9xx5 2P構成のHPE ProLiant DL365/DL385 Gen11 サーバーでコンポーネント整合性ステータスがサポートされていないと表示される</li><li>修正 a00144054en_us: HPE MR Gen10 PlusおよびGen11ストレージコントローラー - システムが VMware ESXiオペレーティング システムを起動すると、SAS/SATA/NVMe ドライブファームウェアのアップデートが成功しない場合があります</li><li>修正 a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - 大量のI/OがアクティブなときにHPE MRSAに予期しない情報が表示される</li><li>CM7 FIPSドライブがSED対応ドライブとして識別されない問題を修正しました。CM7 FIPSドライブモデル番号: VO001920YXUHU、VO003840YXUHV、VO007680YXUJA、MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VV007680LYJKF、VV015360LYXMT、MV003200LYJKH、MV006400LYJKK。</li><li>無効なセキュリティキーを使用して外部ドライブをインポートすると、5回試行してもコントローラーが無限ループに陥る問題を修正しました。</li><li>PCI BARアップデートの進行中に MCTPトラフィックがあるとコントローラーがアサートする可能性がある問題を修正しました。</li><li>Redfish Drive.CapableSpeedGbsがSAS4ドライブに対して22.5ではなく22と表示される問題を修正しました。</li><li>ReuseTargetIdオプションを使用して同じコマンドで複数の論理ドライブを作成すると、作成される論理ドライブの数が予想よりも少なくなる問題を修正しました。</li><li>複数の論理ドライブ構成で固定キャッシュが生成されないことがある断続的な問題を修正</li><li>ホストのタスク管理によりオフライン ドライブ ファームウェアのダウンロードがタイムアウトしたにもかかわらず、ダウンロード完了イベントが生成されるというまれな問題を修正しました。</li><li>サーバーの起動前にキャッシュオフロードが発生すると、RAID5/50/6/60論理ドライブのパフォーマンスが低下する可能性がある問題を修正しました。</li><li>NVMeドライブでパトロール読み取りを実行しているときにコントローラーに障害が発生し、OCR (オンラインコントローラーリセット) で回復する可能性がある問題を修正しました。</li><li>NVMe JBODドライブの最大書き込み同一長または最大アンマップブロック記述子数が上書きされ、SCSI UNMAPまたはWRITE SAMEコマンドが失敗する問題を修正しました。</li><li>ホストが実行時に PCIe BARを構成すると、PCIeメモリ読み取りのUR(サポートされていない要求) が発生する可能性があるというまれな問題を修正しました。</li><li>0より大きく8より小さいパラメーターリストの長さを使用するSCSI UNMAPコマンドが、SCSIセンス キーの不正な要求とパラメーターリスト内の無効なフィールドの追加センスデータで失敗する問題を修正しました。</li><li>PCI bar初期化がブートメッセージ処理を待機してタイムアウトしたためにコントローラーがアサートされる可能性があるというまれな問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The&nbsp;algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and are not applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"cn"}],"Version":"52.30.3-5917"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"cn"}],"Version":"52.32.3-6118"}],"SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b67872fae91a4ce59cd901fe1f0a74c8"}]},{"ProductId":"8d2bd99747b540d2a364efef8e58a91c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"233.1.135007"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135007.Optimized.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"233.1.135007"}]},"MinimumActiveVersion":"226.1.107000","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Broadcom NetXtreme-E Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td><td colspan=\"1\" rowspan=\"7\"><p>233.0.151.0</p></td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td><td colspan=\"1\" rowspan=\"7\"><p>233.0.151.0</p></td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td><td colspan=\"1\" rowspan=\"7\"><p>233.0.151.0</p></td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table></li></ul><p>&nbsp;</p>"}],"Files":[{"Bytes":"8489024","DateModified":"2025-04-22T07:08:19","FileList":["bcm233.1.135007.Optimized.pup.HPb","bcm233.1.135007.Optimized.pup.xml","payload.json"],"MD5Sum":"9c55cf5c35404628dd6e82761bce883e","Name":"bcm233.1.135007.Optimized.pup.fwpkg","Release":"2025-04-22T07:05:34","Revision":"","SHA1Sum":"60a26bde53c10fae9a1ac29b07a74fc2e86d01d4","SHA256Sum":"aa8035e9931c2f45b4f8327bc1440f1459a4bee8a0afb740f267a5b4931b9282","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"TypeOfChange":"1","Version":"233.1.135007"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong>IMPORTANT ADDITIONAL INFORMATION<em>:</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Please be noted that firmware package has the minimum version (NVM Image version 216.0.333011).</p></li><li><p>To update to NVM Image version 216.0.333011 (or later), use the &quot;<em>Online Firmware Upgrade Utility</em>&quot; either from the Service Pack for ProLiant (SPP), or download and install the &quot;<em>Online Firmware Upgrade Utility</em>&quot; manually:</p></li><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Service Pack for ProLiant (SPP): </strong><ul style=\"list-style-type:circle\"><li>The Service Pack for ProLiant (SPP) contains the &quot;<em>Online Firmware Upgrade Utility</em>&quot; and the SPP can run in either offline mode or online mode. The firmware update can be performed either by booting from the SPP to update in offline mode or by running the SPP from the current running operating system and update the firmware in online mode.</li></ul></li></ul><p>OR</p><ul><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Online firmware update utility manually: </strong><ul style=\"list-style-type:circle\"><li>Download and install any of the following &quot;Online Firmware Upgrade Utility&quot; component versions (or later):<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_c9c99d62694e4a6aa418b0a781&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions Version 5.2.3.0 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_2502ce87e3ba481081daea7a6c&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64 Version 1.9.3 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_0d5f5f72693848838710781e5e&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware Version 5.11.6 (or later)</a></li></ul></li></ul></li></ul><p><strong>Note:</strong> After updating to NVM Image version 216.0.333011 (or later) using the &quot;<em>Online Firmware Upgrade Utility</em>&quot;, a reboot is required to enable the new firmware. Once the network adapter has NVM Image version 216.0.333011 (or later) installed and running, the Platform Level Data Model (PLDM) firmware update method (&quot;firmware package&quot; or &quot;fwpkg&quot; file) can be used to update to the latest version.</p><p>&nbsp;</p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, to avoid issues caused by jumping too many versions at once.</li></ul><p style=\"margin-left:40px\">Please refer to the following link.</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong>IMPORTANT ADDITIONAL INFORMATION<em>:</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Please be noted that firmware package has the minimum version (NVM Image version 216.0.333011).</p></li><li><p>To update to NVM Image version 216.0.333011 (or later), use the &quot;<em>Online Firmware Upgrade Utility</em>&quot; either from the Service Pack for ProLiant (SPP), or download and install the &quot;<em>Online Firmware Upgrade Utility</em>&quot; manually:</p></li><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Service Pack for ProLiant (SPP): </strong><ul style=\"list-style-type:circle\"><li>The Service Pack for ProLiant (SPP) contains the &quot;<em>Online Firmware Upgrade Utility</em>&quot; and the SPP can run in either offline mode or online mode. The firmware update can be performed either by booting from the SPP to update in offline mode or by running the SPP from the current running operating system and update the firmware in online mode.</li></ul></li></ul><p>OR</p><ul><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Online firmware update utility manually: </strong><ul style=\"list-style-type:circle\"><li>Download and install any of the following &quot;Online Firmware Upgrade Utility&quot; component versions (or later):<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_c9c99d62694e4a6aa418b0a781&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions Version 5.2.3.0 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_2502ce87e3ba481081daea7a6c&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64 Version 1.9.3 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_0d5f5f72693848838710781e5e&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware Version 5.11.6 (or later)</a></li></ul></li></ul></li></ul><p><strong>Note:</strong> After updating to NVM Image version 216.0.333011 (or later) using the &quot;<em>Online Firmware Upgrade Utility</em>&quot;, a reboot is required to enable the new firmware. Once the network adapter has NVM Image version 216.0.333011 (or later) installed and running, the Platform Level Data Model (PLDM) firmware update method (&quot;firmware package&quot; or &quot;fwpkg&quot; file) can be used to update to the latest version.</p><p>&nbsp;</p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, to avoid issues caused by jumping too many versions at once.</li></ul><p style=\"margin-left:40px\">Please refer to the following link.</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong>IMPORTANT ADDITIONAL INFORMATION<em>:</em></strong></p><p><strong><em>(1.)</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Please be noted that firmware package has the minimum version (NVM Image version 216.0.333011).</p></li><li><p>To update to NVM Image version 216.0.333011 (or later), use the &quot;<em>Online Firmware Upgrade Utility</em>&quot; either from the Service Pack for ProLiant (SPP), or download and install the &quot;<em>Online Firmware Upgrade Utility</em>&quot; manually:</p></li><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Service Pack for ProLiant (SPP): </strong><ul style=\"list-style-type:circle\"><li>The Service Pack for ProLiant (SPP) contains the &quot;<em>Online Firmware Upgrade Utility</em>&quot; and the SPP can run in either offline mode or online mode. The firmware update can be performed either by booting from the SPP to update in offline mode or by running the SPP from the current running operating system and update the firmware in online mode.</li></ul></li></ul><p>OR</p><ul><li><strong>Update to NVM Image version 216.0.333011 (or later) using the Online firmware update utility manually: </strong><ul style=\"list-style-type:circle\"><li>Download and install any of the following &quot;Online Firmware Upgrade Utility&quot; component versions (or later):<ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_c9c99d62694e4a6aa418b0a781&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions Version 5.2.3.0 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_2502ce87e3ba481081daea7a6c&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64 Version 1.9.3 (or later)</a></li><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_0d5f5f72693848838710781e5e&amp;tab=releaseNotes\" style=\"color:#467886; text-decoration:underline\" target=\"_blank\">HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware Version 5.11.6 (or later)</a></li></ul></li></ul></li></ul><p><strong>Note:</strong> After updating to NVM Image version 216.0.333011 (or later) using the &quot;<em>Online Firmware Upgrade Utility</em>&quot;, a reboot is required to enable the new firmware. Once the network adapter has NVM Image version 216.0.333011 (or later) installed and running, the Platform Level Data Model (PLDM) firmware update method (&quot;firmware package&quot; or &quot;fwpkg&quot; file) can be used to update to the latest version.</p><p>&nbsp;</p><p><strong><em>(2.)</em></strong></p><ul style=\"list-style-type:square\"><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, to avoid issues caused by jumping too many versions at once.</li></ul><p style=\"margin-left:40px\">Please refer to the following link.</p><p style=\"margin-left:40px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\" title=\"https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83\">https://www.hpe.com/global/swpublishing/MTX-dd6fb2ccd23c4884a8aae66c83</a></p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eファームウェアパッケージfor BCM5741xアダプター"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-01T09:12:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanIdプロパティを削除します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断を向上させます。</li><li>この製品は、よりクリーンなインターフェイスを実現するために、HII MBAメニューを抑制するドライバーのアップデートを強化しています。</li></ul>","Fixes":"<ul><li>この製品は、RDMA接続が確立されない問題を修正します。</li><li>この製品は、RoCEおよびTX/RXパスコアダンプのデコードが失敗する問題を修正します。</li><li>この製品は、ESXiでポート1がブロードキャストパケットを受信できない問題を修正します。</li><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、VLAN構成でPXEブートが機能しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"cn"}],"Version":"232.1.132008"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.1.135007"}],"SWKeys":[{"Name":"NIC_NXE_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"f9f6c8d4f7714e8e85d4276f664f48dd"}]},{"ProductId":"ad3fba5acbb54355b6ab78730e8d2635","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1415136","DateModified":"2025-04-01T05:50:16","FileList":["cp065297.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"6a63f66a256e13f68139d7a0dab4e1d6","Name":"cp065297.exe","Release":"2025-04-01T05:36:15","Revision":"B","SHA1Sum":"07d4de9b075b4c9cf5be6a7a736783807ca06f26","SHA256Sum":"137f1e4fbcb7e42b5a40fe3a8a9f1406eb4e1a8664fd4e22ab5740f4e6e78930","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel iavf Driver for Windows Server 2025"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:48:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.316.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7f76976e07a54576b8e018fa2fd129a5"}]},{"ProductId":"0c95f7c054f047b69fbfe7c93264a982","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3278296","DateModified":"2025-01-10T10:19:21","FileList":["cp065033.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"MD5Sum":"92cc49395abc8a1f23659d5074aa3242","Name":"cp065033.exe","Release":"2025-01-10T10:14:56","Revision":"G","SHA1Sum":"c0a8df4563245f3c7dc7170615b0e0b8212dd7c0","SHA256Sum":"a7316681efcac7f1d666e41e451590e02881faac89bbb74476aa8e1fdcec3b21","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000JWJRQおよび MB006000JWJRPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:29:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b3c2b4c403c3491c8fba712a8c254a5c"}]},{"ProductId":"1174220fe8354722a040071980d1eb37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2025用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2339328","DateModified":"2025-03-25T09:14:19","FileList":["cp066447.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"d6c9c154ce450e74012fcc010e0cfd86","Name":"cp066447.exe","Release":"2025-03-25T09:00:43","Revision":"","SHA1Sum":"2277bcb60630eafb77419ac6b6e4ae25bc82d2ee","SHA256Sum":"0884bc9087b8705545bbf221e145d13102d19e5244378cad7d6ac21f518a23de","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"927d2f75e08f4b78ad4231a8b92b10d8"}]},{"ProductId":"dac1034844fb4856950db71b5b2c959d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1242832","DateModified":"2025-04-01T02:00:18","FileList":["cp065358.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"c91419479a4100adc9b3c75f38646357","Name":"cp065358.exe","Release":"2025-04-01T01:45:49","Revision":"","SHA1Sum":"8b5e7f053001841ca2e90c30ef9ed1069945910c","SHA256Sum":"041d49d1f0eef07b8542b6fd66b3b89f960185e1616a1de974af647cb117a5dd","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40ea Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel i40eaドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel i40ea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103C0000","Type":"pci","Ven":"8086"},{"Dev":"158A","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-158A15900000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T08:21:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5104ee92a3724161bb39d8e94e7f7bbc"}]},{"ProductId":"968a9e036afd4092af43608fa1a5a87c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4362072","DateModified":"2025-01-11T12:10:12","FileList":["cp065087.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKESD3.rel"],"MD5Sum":"e1fbc0beeb3f1b4331d5beb438a994bd","Name":"cp065087.exe","Release":"2025-01-11T12:06:13","Revision":"B","SHA1Sum":"0d33aa94fec5e23c730e14d5eacdf3f90221a0fb","SHA256Sum":"7ccd789ec67fbf80eae02b7cdd141f0a130daf41b3407b20bd7f768d5bb4f22c","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"},{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:38:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"338e51f3673543e4a0e92ad7a9f40137"}]},{"ProductId":"7dbb2b9a498c4df1a461e7b3079cc8f5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"233.1.135007"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 233.1.135007&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"7990727","DateModified":"2025-04-08T21:48:18","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/CP066632.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/CP066632.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.24.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066632.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066632.scexe"],"MD5Sum":"49547de6d9512cc071c0aa59b62421fc","Name":"firmware-nic-bcm-nxe-1.24.0-1.1.x86_64.rpm","Release":"2025-04-09T02:41:00","Revision":"","SHA1Sum":"34680695804c08cfad3f7f1da5d79457f97e45a6","SHA256Sum":"eb478c338146e0227a3e1980a987173daa81a42d9aac8aedd4ce0d74520024a4","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.24.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command: <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em></li></ul><p style=\"margin-left:80px\">This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>インストールされたrpmによるアダプターファームウェアのアップデート。</strong></em></p><ul><li>コマンド<em>rpm -ivh <rpm_filename>.rpmを使用して、このNICファームウェアrpmをインストールします。  </em></li></ul><p style=\"margin-left:80px\">このコマンドは、\"/usr/lib/x86_64-linux-gnu\"へコンテンツを抽出します。<br />CPXXXXXX.scexeスクリプトは、\"scexe-compat''フォルダーにあります。詳細については、\"firmware-nic-*\"フォルダーのCPXXXXXX.txtファイルを参照してください。\"firmware-nic-*\"フォルダーの実際の名前は、インストールされるrpmのバージョンに基づきます。  </p><ul><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します。<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>（\"/usr/lib/x86_64-linux-gnu/scexe-compat\"内）。</li><li>firmware-nic-*ロケーションの<em>./setup</em>   </li></ul></li><br /><li>このrpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li></ul><p><em><strong>rpmのインストールなしでのアダプターファームウェアのアップデート。</strong></em></p><ul><li>rpmの内容を次のコマンドを入力して抽出します：<em>rpm2cpio <rpm_filename>.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</p><ul><li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-nic-フォルダーの実際の名前は、rpmのバージョンに基づきます。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアアップグレードの結果は、\"/var/cpq/\"にあるCPXXXXXX.logに保存されます。</li><li>NPAR（NICパーティショニング）モードを有効化すると、デバイスIDが変更されます。これに従い、NPARを有効化すると、DID 0x16D7および0x16D8を使用するアダプターが、0x16ECおよび0x16EEにそれぞれ変更されますが、NPARを有効化し、RoCEも有効化すると、0x16EDおよび0x16EFに変更されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアrpmパッケージのインストール (rpm -ivh)は、アダプターのファームウェアをアップデートしません。rpmのインストールは、単にローカルシステムへrpmの内容を解凍するだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップグレードする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップグレードしていきます。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command: <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em></li></ul><p style=\"margin-left:80px\">This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p style=\"margin-left:80px\">This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-01T09:12:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanIdプロパティを削除します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断を向上させます。</li><li>この製品は、よりクリーンなインターフェイスを実現するために、HII MBAメニューを抑制するドライバーのアップデートを強化しています。</li></ul>","Fixes":"<ul><li>この製品は、RDMA接続が確立されない問題を修正します。</li><li>この製品は、RoCEおよびTX/RXパスコアダンプのデコードが失敗する問題を修正します。</li><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、VLAN構成でPXEブートが機能しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"cn"}],"Version":"1.23.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.24.0"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"0269876a1583462b91a9e5019d2583a8"}]},{"ProductId":"5f4b3c5f1985447a820cdfec1e7b0bb1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1036952","DateModified":"2025-04-01T02:55:17","FileList":["cp065355.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"e4555d9fa4a1a2e08ffc2236df31011c","Name":"cp065355.exe","Release":"2025-04-01T02:41:36","Revision":"B","SHA1Sum":"e85dd1c11d82007df4dead112738eb8bb40d1133","SHA256Sum":"ea8960cf2afef4fb6f7005f0bc293ba23cb1ff5324bf430007d280f49ca6a602","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.2.6.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2025"},{"Lang":"ja","Value":"Windows Server 2025用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T07:37:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"4.2.6.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.2.6.0"}],"SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a4d6893352c4492680ca1df4f865180e"}]},{"ProductId":"d36b5614c00b4d00b66a58209cc5bffb","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11626055","DateModified":"2025-05-14T21:37:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/CP067213.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/U41_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067213.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067213.scexe"],"MD5Sum":"8d02dd8c9434c8c7178b33748b9b9299","Name":"firmware-system-u41-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T02:29:05","Revision":"B","SHA1Sum":"07ece9297f1745f5785676b91a5756b8ecce137f","SHA256Sum":"e913ff46de22fa60cad002bf5003d04278ef8f69215ae30e8a053d6b92e7211a","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML350 Gen10 (U41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T02:20:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e2b2c3c3b83469abadd65dc7e0102bb"}]},{"ProductId":"be56d38accd045cca89d446f2db8440b","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3772.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains utilities and firmware for HPE ProLiant Gen9 and Gen10 server series the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2019, Windows Server 2022 and Windows Server 2025"},{"Lang":"ja","Value":"This component contains utilities and firmware for HPE ProLiant Gen9 and Gen10 server series the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2019, Windows Server 2022 and Windows Server 2025"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12672664","DateModified":"2025-04-01T07:21:52","FileList":["cp065265.xml","cpqsetup.exe","for_Gen9/","for_Gen9/install.bat","for_Gen9/iqvw64e.cat","for_Gen9/iqvw64e.inf","for_Gen9/iqvw64e.sys","for_Gen9/uninstall.bat","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_366FLR_G41713-00x_800011A1.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_800011F1.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","FW/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","FW/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","FW/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"d4c944a569b14570889b9589ce669a15","Name":"cp065265.exe","Release":"2025-04-01T07:14:00","Revision":"B","SHA1Sum":"b33ddff0343874f2e83f6f60a5eaeb943303f02f","SHA256Sum":"53ae16fce55636bc4e4760b05cd694b376b43e2472199039dfe667fe9cafb2f4","Size":"12MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"5.4.4.1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1800,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 2-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_usを参照してください。</li><li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後にAC電源を再投入する必要があります。<br />HPE Ethernet 1Gb 2ポート 368iアダプター<br />HPE Ethernet 1Gb 2ポート369iアダプター<br />HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター <br />HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor Windows Server x64 Editions（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4100"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:20:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"5.4.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"5.4.4.1"}],"SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"59d68ed4847143f2b56bcc8f6f1969f0"}]},{"ProductId":"d3fcc87b38304a8db3d98d71c7c32227","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"},{"Lang":"cn","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"},{"Lang":"ja","Value":"VMware ESXi 8.0 Update 3 Mellanox mst driver for Mellanox devices"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"33088","DateModified":"2025-03-19T08:50:54","FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp052054.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"MD5Sum":"34dc15abf72ecba71284150a2c32fd45","Name":"cp052054.zip","Release":"2025-03-19T08:49:53","Revision":"","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","Size":"32KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"cn","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"},{"Lang":"ja","Value":"<p><strong>Remote Online:&nbsp;</strong></p><ol><li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li><li>Mount the USB key on a remote server running Windows or Linux .</li><li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li><li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li><li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li><li>Click, &quot;Add Node&quot;.<ul><li>If adding a Gen9 server,<ul><li>Provide IP address of the ESXi host.</li><li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li></ul></li><li>If adding a Gen10 and above server,<ul><li>Provide iLO IP address of the ESXi host server.</li><li>Enter the iLO credentials of the ESXi host server.</li></ul></li></ul></li><li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware VUM or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"},{"Lang":"cn","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"},{"Lang":"ja","Value":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"8020","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c8020","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"801F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c801f","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F4","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f4","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F2","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f2","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f3","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"1007","SubDev":"22F5","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f5","Type":"pci","Ven":"15b3"},{"Dev":"1007","SubDev":"22F1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-15b3-1007103c22f1","Type":"pci","Ven":"15b3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"0221","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101315900221","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2022-06-09T04:27:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>NMST version&nbsp;4.31.0.150</p><p>&nbsp;</p><p>This version is supported on VMware ESXi 8.0 Update 3&nbsp;only.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.17"}],"SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"","Model":"HPE Apollo sx40 Server"},{"Family":"","Model":"HPE Apollo pc40 Server"},{"Family":"","Model":"HPE Apollo kl20 Server"},{"Family":"","Model":"HPE Apollo am35 Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"710b214b710b478db82f6f2cc0c9f094"}]},{"ProductId":"ccbfcdbdc47644e7ab18a371d4af9d7a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11825936","DateModified":"2025-04-18T12:59:08","FileList":["cp066831.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_3.50_04_17_2025.signed.flash"],"MD5Sum":"511cc169f0b15a542b10b4e219c4e9b2","Name":"cp066831.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"6e63a565709481f69f70c8e0f56fdf3e04d23225","SHA256Sum":"0edb5d566509b1a38d06b33db751ceba17e1f0fa1914b861ba81f58693385729","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"f3aea5705c5041648ac218de904b8e77"}]},{"ProductId":"a5b53b4bfa36450dafe72d3912e27c73","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1074234","DateModified":"2025-04-01T08:05:04","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.39.1.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/ice","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/db8ce1d055ed3de1f4bfad56f3ddf970247e14","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"MD5Sum":"8274781c8c88425be59529a4769a8ffb","Name":"kmod-ice-1.16.4-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T07:58:04","Revision":"B","SHA1Sum":"cb0f16d4c7ea777a01180413e4c7da22fbc91590","SHA256Sum":"74dc4bbdc2198492556bbb7669e1dcfd4e56ba22061a6b8b28715e6dbf6d6115","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"1.16.4-1"},{"Bytes":"1075580","DateModified":"2025-04-01T08:10:11","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.39.1.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/ice","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/49","./usr/lib/.build-id/49/889fe084a20e4f0f86beca1bbca9b47ebb18bb","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"MD5Sum":"2c74c909eccaca5182b696b6a9a4b9ce","Name":"kmod-ice-1.16.4-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T07:58:04","Revision":"B","SHA1Sum":"42fa25fff58368f432da394653c372fb08cb782a","SHA256Sum":"7207d30b45893fdb3b6ea12cee5a4a0bd1327d9160ceee238420a379ddca0a07","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"1.16.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel ice Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"Intel iceドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"Intel ice Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T06:54:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"cn"}],"Version":"1.16.4-1"}],"SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fb00fd55e60c4887bd3a930235a5ab2f"}]},{"ProductId":"bafc8d47aead420a9621e8d49861aa9b","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33605191","DateModified":"2025-05-21T12:34:48","FileList":["A43_3.72_05_16_2025.signed.flash","A43_3.72_05_16_2025.xml","payload.json"],"MD5Sum":"d17a644b7182caefb675b90dcdc14aca","Name":"A43_3.72_05_16_2025.fwpkg","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"813cd96f5f5a4f37bd813aea73c96b407b0167d2","SHA256Sum":"269e73b8b48acfb178afe7abb2c064cb6e8c3b91b8c5c1488b97cda153bed7bf","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"467b3c64de644d70b2e88eae3f7244e6"}]},{"ProductId":"2ef4b1fccb0b4e4aa4c8281327ada522","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4890377","DateModified":"2025-05-24T07:32:04","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"MD5Sum":"8b3685ec9acdafec87595af6d1a636aa","Name":"qlgc-qla2xxx-kmp-default-10.02.14.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"defd452d23b75ea01d39a202bf6a5d0d31a816b2","SHA256Sum":"7153dcbd8877ba472f113182c0c669d00fc28947ccf696e66e72a002184781af","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.14.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.3.18_57-2.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br /><br />                    # rpm -Uvh qlgc-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.3.18_57-2.sles15sp4.x86_64.rpm</p><p>4.  インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br /><br />                    セットアップが完了しました。コンピューターをただちに再起動してください。</p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                    # rpm -e qlgc-qla2xxx-<version>.<OSupdate>.x86_64</p><p>同じドライバーバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります</p><p>例：rpm –Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm --reinstall</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.10.00_k1_k5.3.18_57-2.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 6ファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプター"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーをバージョン10.02.14.00-k1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"}],"SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8482fa2bf1c34b14bb1dde5a7ea729a3"}]},{"ProductId":"fa3afb08b69b4eb3ac32d9088c68d3a9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Addresses a hot plug reporting concern.</li><li>Increased the buffer memory size used for sequential write data to resolve performance degradation seen in a RAID60 configuration.</li><li>Remove Background Media Scan (BMS) with Super parity and Directed Offline Scan (DOS).</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6239099","DateModified":"2025-05-14T08:01:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/CP066509.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066509.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066509.scexe"],"MD5Sum":"38ff708133eff1cdd10b7b0d0737c972","Name":"firmware-hdd-cf0b6cabe1-HPD4-6.1.x86_64.rpm","Release":"2025-05-14T12:50:04","Revision":"F","SHA1Sum":"81bf3414f62b574d86bcead397ef4cc34e29a0ee","SHA256Sum":"693a745cf050e10c54fe80e5c31083d113b0d87a5b5a63763f4ef2ce182eb0fc","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64） - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:32:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"20535a82fb3540f4b28c1aadb59ee7cf"}]},{"ProductId":"8e8482d9e6e6494a8e54ec40143d190a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"125550","DateModified":"2025-04-23T02:05:09","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"MD5Sum":"113f1dbb90c0e3bb7b1966ba1c3dc15b","Name":"tg3-kmp-default-3.139t_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","Release":"2025-04-23T01:59:20","Revision":"","SHA1Sum":"abcb83207ad0017c783f645778bfea0aa2cac8ac","SHA256Sum":"029aa7b9083415db644b8690a84c294e60eb606f9fdb0780e7bf22dfebcdd837","Size":"122KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139t-2"},{"Bytes":"120782","DateModified":"2025-04-23T02:08:34","FileList":["./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"MD5Sum":"d611b96a6e86c0f46597691e8bfcc7b2","Name":"tg3-kmp-default-3.139t_k5.14.21_150500.53-2.sles15sp5.x86_64.rpm","Release":"2025-04-23T01:59:20","Revision":"","SHA1Sum":"722181ae5d1be03c4e8884f049d7adce2c6fbee3","SHA256Sum":"65bc099a8f44f66e1e1bea387394cc8740b0fadfb62ff5eab832f00b7d040ca7","Size":"117KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.139t-2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download README for installation instructions.</p>"},{"Lang":"ja","Value":"<p>インストール手順についてのREADMEをダウンロードします。</p>"},{"Lang":"cn","Value":"<p>Download README for installation instructions.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T03:12:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fix issue where tg3 driver doesn&#39;t report correct tg3 driver name in dmesg.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、tg3ドライバーがdmesgで正しいtg3ドライバー名を報告しない問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fix issue where tg3 driver doesn&#39;t report correct tg3 driver name in dmesg.</p>","Lang":"cn"}],"Version":"3.139q-2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.139t-2"}],"SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b7369d1a8a734e8fb6e03985f2673c85"}]},{"ProductId":"e6fc00ad6a3e4c539778e7419a9fafa6","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6264542","DateModified":"2025-06-16T05:52:16","FileList":["20_43_2566-MCX653435A-HDA_HPE_Ax.pldm.signed","20_43_2566-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"0ef750828780a41cfe9f4ab9d104ff35","Name":"20_43_2566-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:50:19","Revision":"","SHA1Sum":"bd2950e1ab44c352c970994986c137504b3f5ce7","SHA256Sum":"684a63ab2be6900f40f56d61f43d369572b83ce65215744941bdb36ce1403370","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900347"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T06:56:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"7dfe5a924aae4c9f83d18e91ab938d50"}]},{"ProductId":"aa62b707fef04bb99492053e558daffb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5868109","DateModified":"2025-05-15T10:45:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/CP066516.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/TAMG08scHPDC.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066516.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066516.scexe"],"MD5Sum":"62d1ffed1772740ddc84f62d4b5c7132","Name":"firmware-hdd-8a0371a425-HPDC-2.1.x86_64.rpm","Release":"2025-05-15T15:33:04","Revision":"B","SHA1Sum":"b1da0c5e6b7fb7c824343642f13c61dcbaa92b7d","SHA256Sum":"7a35ed21d8940c53fd77092ce1be178779f4fb46939081bb4702393542d1443b","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T04:19:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。</li><li>このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5f7c07702a8741cbb71faac1d8ea0595"}]},{"ProductId":"dd83343964ed4806840a86595ee2254d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3734992","DateModified":"2025-01-11T08:29:15","FileList":["cp065077.xml","cpqsetup.exe","KARM5ALSHPD8.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"4768f20fbbe95d23f09cc6115fd1da73","Name":"cp065077.exe","Release":"2025-01-11T08:25:26","Revision":"C","SHA1Sum":"3d364c23c86e6220a1184e67e47b3f25c8f6f2de","SHA256Sum":"1d7af94be1b34da049a8a43186ba5e1e13188caf2ff76376019907bc59fafe56","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T05:51:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9dc081801c834a77aff4e4ab311333bf"}]},{"ProductId":"ae86717eaef841a7919ea42f85ca3fe7","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2025 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"},{"Lang":"ja","Value":"This driver, MegaSAS35, provides Windows 2025 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"903288","DateModified":"2025-04-25T04:34:13","FileList":["cp064820.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","megasas35.inf","megasas35.pdb","megasas35.RttMeta","megasas35.sys","nodev.inf"],"MD5Sum":"f157f2375def524be5a38a2c2a668be4","Name":"cp064820.exe","Release":"2025-04-25T04:32:01","Revision":"B","SHA1Sum":"f659a2582bc02f511945791c078a29c6aaab1912","SHA256Sum":"851bf44519ec6fca8a2ae1425cdc682efbaaa292c2d30f525b139771c42bdb84","Size":"882KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition"},{"Lang":"ja","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいGen12 サーバーをサポートします。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.730.2.0"},{"ReleaseNotes":[{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"df05d5e27fe2442bbc0ca33e6318e933"}]},{"ProductId":"9f1ff08535434ba0ad3d9924079f9908","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-305958554a42","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-305958554a43","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-305958554a44","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-305958554855","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-305958554856","Version":"HPK3"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-305958554a41","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2514517","DateModified":"2024-11-12T08:41:16","FileList":["Kioxia_CM7_KACM7ALFHPK3.HPb","Kioxia_CM7_KACM7ALFHPK3.xml","payload.json"],"MD5Sum":"d082497c539576f7bcb536cf3cf165cf","Name":"Kioxia_CM7_KACM7ALFHPK3.fwpkg","Release":"2024-11-12T08:38:55","Revision":"","SHA1Sum":"7d9b39dfad661cbd0ff744324d4d500c5d2674bc","SHA256Sum":"2f7ba0097a06722113509819e811b9c4bd943e37012ae6b6acf91af9f94b50ee","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600YXUJB","TargetGUID":"4d2340a5-304f-3130-3630-305958554a42","Type":"nvme"},{"Id":"MO003200YXUJC","TargetGUID":"4d2340a5-304f-3330-3230-305958554a43","Type":"nvme"},{"Id":"MO006400YXUJD","TargetGUID":"4d2340a5-304f-3630-3430-305958554a44","Type":"nvme"},{"Id":"VO001920YXUHU","TargetGUID":"562340a5-304f-3130-3932-305958554855","Type":"nvme"},{"Id":"VO003840YXUHV","TargetGUID":"562340a5-304f-3330-3834-305958554856","Type":"nvme"},{"Id":"VO007680YXUJA","TargetGUID":"562340a5-304f-3730-3638-305958554a41","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-12T08:08:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Fix 1) PCIe link length drop in AMD x2 system configuration<br />&nbsp;&nbsp;&nbsp; 2) Drive detection after hot re-insert on Windows<br />&nbsp;&nbsp;&nbsp; 3) Other regular FW patch release.</p>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"MO001600YXUJB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200YXUJC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400YXUJD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920YXUHU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840YXUHV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680YXUJA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"1e716f77e5834081b2f12ab399b85ff2"}]},{"ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"https://www.hpe.com/info/ilo-docs\">www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"https://www.hpe.com/info/ilo-docs\">www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"33588606","DateModified":"2025-06-16T10:46:11","FileList":["ilo5_314.bin","ilo5_314.xml","payload.json","readme.txt"],"MD5Sum":"b8e8cd992a83102f0bad2346e4ab0bd2","Name":"ilo5_314.fwpkg","Release":"2025-06-16T10:42:17","Revision":"","SHA1Sum":"bb62b20347275de287285ef6356dc688b747bbc4","SHA256Sum":"19a4a6aca7e55720ef707982dbab737dbeb6710a23e4653ad5eb2a159d0df103","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.14"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュファームウェアパッケージ - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32801"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-28T04:49:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"en"},{"Enhancements":"<p>公開キー認証方式によるHPE iLO SSHへのログインでSHA2アルゴリズムをサポートし、すべてのセキュリティモードに適用できます。</p>","Fixes":"<p>• ディスク障害時にHPE Gen10サーバーのヘルスLEDの点滅がHPE iLO v3.01とHPE iLO v3.02とで異なる動作を示す問題を修正しました。</p><p>• イベントサブスクリプションでmTLSが使用されている場合にRedfishイベントが正しく送信されない問題を修正しました。</p><p>• DHE-RSA暗号が<strong>弱い暗号を無効化</strong>かつ<strong>高セキュリティ</strong>モードの設定で有効になっているとHPE iLOが脆弱になる問題を修正しました。</p><p>• Zabbixモリタリングソフトウェアで監視されている場合にHPE iLO 5 v3.10が<strong>snmpwalk timeout</strong>を返す問題を修正しました。</p><p>• ユーザーのドメイン名に<strong>\\</strong>文字が含まれているとget_email_detailsが失敗する問題を修正しました。</p><p>• 一部のサーバーで証明書のインポートが失敗して<strong>SSL certificate could not be imported since the input certificate is not intended for this server</strong>エラーになる問題を修正しました。</p><p>• HPE iLO6のシステム情報のストレージタブにドライブが順序なしで表示される問題を修正しました。</p><p>• ドライブの検出で、ドライブの取り外しまたは挿入を誤って報告するIMLメッセージがトリガーされる問題を修正しました。</p><p>• HPE Apolloサーバーの電源装置の冗長化の状態に関する問題を修正しました。</p><p>• m750サーバーブレードがクリティカル状態になり、HPE iLOに接続できなくなる問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"cn"}],"Version":"3.13"},{"ReleaseNotes":[{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"en"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"ja"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"cn"}],"Version":"3.14"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"2fc444a8965c494eaa0d5ff790004e14"}]},{"ProductId":"5156ee2ce74d4685bd9c2931c6170220","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (hp-iavf-kmp-default) to (iavf-kmp-default). Now we revert this change from (iavf-kmp-default) to (<strong>hp</strong>-iavf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-iavf-kmp-default and iavf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e iavf-kmp-default and then install the updated RPM.</li></ul>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。<br />* 以前のWebリリースiavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（hp-iavf-kmp-default）から（iavf-kmp-default）に変更されました。この変更を（iavf-kmp-default）から（<strong>hp</strong>-iavf-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-iavf-kmp-defaultとiavf-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにiavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e iavf-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</li></ul>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (hp-iavf-kmp-default) to (iavf-kmp-default). Now we revert this change from (iavf-kmp-default) to (<strong>hp</strong>-iavf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-iavf-kmp-default and iavf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install iavf-kmp-default-4.9.1_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e iavf-kmp-default and then install the updated RPM.</li></ul>"}],"Files":[{"Bytes":"157205","DateModified":"2025-04-01T08:34:11","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/hp-iavf","./lib/modules/5.14.21-150500.53-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"MD5Sum":"f11c482e18e1bae07aeb4c3c9f0ae08f","Name":"hp-iavf-kmp-default-4.13.4_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T08:28:04","Revision":"B","SHA1Sum":"ce48f322d488254c66420d230d7481196cf3ca49","SHA256Sum":"a926d4d46bf4c105d5831884b23d7bb05815e9ed8e33a904d2306ef1c511efd2","Size":"153KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.4-1"},{"Bytes":"186597","DateModified":"2025-04-01T08:38:26","FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"MD5Sum":"7119352354eaa214b035583a638d31b9","Name":"hp-iavf-kmp-default-4.13.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T08:28:04","Revision":"B","SHA1Sum":"262cc8103a34d6e490c7da33ff6d0869f29eb7d1","SHA256Sum":"69a419e00c859b2d2eecc2c673f358a7007e574ec778ab82330965344672db17","Size":"182KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"15FF","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15ff8086000c","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"37cd","Type":"pci","Ven":"8086"},{"Dev":"0dd5","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:17:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"4.12.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"4.13.4-1"}],"SWKeys":[{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b1189f681d5a42949cac7ad8da749295"}]},{"ProductId":"e1df01bf9927457096858061671e6c6b","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.473.14"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.473.14"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.473.14"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.473.14"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14447314.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.473.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4812195","DateModified":"2025-03-10T11:53:47","FileList":["/CP064176_BUILD_13.data","/CP064176.vmexe","/CP064176.vmexe64","/CP064176.vmfile","/CP064176_VMw.zip","/CP064176.xml","/payload.json","/CP064176_VMw.zip/index.xml","/CP064176_VMw.zip/vendor-index.xml","/CP064176_VMw.zip/metadata.zip","/CP064176_VMw.zip/vib20/CP064176/HPE_bootbank_CP064176_CP064176.13-1OEM.900.0.24580437.vib","/CP064176_VMw.zip/metadata.zip/vendor-index.xml","/CP064176_VMw.zip/metadata.zip/vmware.xml","/CP064176_VMw.zip/metadata.zip/vibs/CP064176-8354935045549477043.xml","/CP064176_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064176_CP064176.13-1OEM.900.0.24580437.xml"],"MD5Sum":"dce786ed40cc73baa83aa959e2cb46f5","Name":"CP064176.zip","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"362232ea5af77f3bf30839023d3a5179a7253d57","SHA256Sum":"ece1799fdfd439e4d06363267e2557c8a01fa41894654b96d9014ae10f92c442","Size":"4MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2025.03.01","VibList":[{"Name":"CP064176","Version":"CP064176.13-1OEM.900.0.24580437"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  9.0"},{"Lang":"ja","Value":"HPE ファームウェアフラッシュ for Emulex ファイバーチャネルホストバスアダプターfor VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"20000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>アダプター</strong></p></td><td><p dir=\"LTR\"><strong>速度</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>ファームウェア</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>ブートBIOS</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE SN1700E 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE SN1700E 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><p dir=\"LTR\"><strong>Adapter</strong></p></td><td><p dir=\"LTR\"><strong>Speed</strong></p></td><td><p dir=\"LTR\"><strong>Universal Boot Image</strong></p></td><td><p dir=\"LTR\"><strong>Firmware</strong></p></td><td><p dir=\"LTR\"><strong>UEFI</strong></p></td><td><p dir=\"LTR\"><strong>Boot Bios</strong></p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.14</p></td><td><p dir=\"LTR\">14.4.473.8</p></td><td><p dir=\"LTR\">14.4.469.0</p></td></tr><tr><td>HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr><tr><td>HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>14.4.473.14</td><td>14.4.473.14</td><td>14.4.473.8</td><td>14.4.469.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"}],"SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3b2772bb95114a73a40b1b23736ad535"}]},{"ProductId":"92d52e2161c24f8f9ff633da842f814c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ<br /> <br /><strong>リリースバージョンおよび/または日付：</strong><br />      GPK7</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />         GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />         GPK6</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの依存関係：<br />      </strong>なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点：</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     </strong>なし</p>"}],"Files":[{"Bytes":"20417183","DateModified":"2025-03-06T05:14:02","FileList":["/CP065951_BUILD_3.data","/CP065951.vmexe64","/CP065951.vmfile","/CP065951_VMw.zip","/CP065951.xml","/payload.json","/CP065951_VMw.zip/index.xml","/CP065951_VMw.zip/vendor-index.xml","/CP065951_VMw.zip/metadata.zip","/CP065951_VMw.zip/vib20/CP065951/HPE_bootbank_CP065951_GPK7.3-1OEM.800.1.0.20613240.vib","/CP065951_VMw.zip/metadata.zip/vendor-index.xml","/CP065951_VMw.zip/metadata.zip/vmware.xml","/CP065951_VMw.zip/metadata.zip/vibs/CP065951-1213375781779043581.xml","/CP065951_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065951_GPK7.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0c02b10d0358a7e3f7aff9c2ca661da5","Name":"CP065951.zip","Release":"2025-03-06T05:13:18","Revision":"C","SHA1Sum":"294ebf6e5d33d8b51e4d974a615880baea62d0e0","SHA256Sum":"027e13f4a78e1514d71affb5bb77009c162689d936eca5c86a23cce0c6a11286","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK7","VibList":[{"Name":"CP065951","Version":"GPK7.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:37:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2b4c0646f81a4caaa9e5e1f7aac8a0ae"}]},{"ProductId":"5e76fbf672b8432aa6436d748dacb463","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWJRQおよびMB006000JWJRP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18129037","DateModified":"2025-03-07T10:44:47","FileList":["/CP065930_BUILD_7.data","/CP065930.vmexe64","/CP065930.vmfile","/CP065930_VMw.zip","/CP065930.xml","/payload.json","/CP065930_VMw.zip/index.xml","/CP065930_VMw.zip/vendor-index.xml","/CP065930_VMw.zip/metadata.zip","/CP065930_VMw.zip/vib20/CP065930/HPE_bootbank_CP065930_HPD9.7-8.0.0.20613240.vib","/CP065930_VMw.zip/metadata.zip/vendor-index.xml","/CP065930_VMw.zip/metadata.zip/vmware.xml","/CP065930_VMw.zip/metadata.zip/vibs/CP065930--1350340004423881024.xml","/CP065930_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065930_HPD9.7-8.0.0.20613240.xml"],"MD5Sum":"ce0e829ab90e239455f8c0a330096412","Name":"CP065930.zip","Release":"2025-03-07T10:43:50","Revision":"G","SHA1Sum":"3e2018e725bbc2be281e65d99657c3e8bd2c7392","SHA256Sum":"44d1209e8831d63a8ef9ee7b5d5267ee61c694a2de7804b56e0629e1bf3ae4a5","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP065930","Version":"HPD9.7-8.0.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br /><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWJRQおよび MB006000JWJRP ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000JWJRQ","TargetGUID":"4d2340a5-3042-3830-3030-304a574a5251","Type":"sas"},{"Id":"MB006000JWJRP","TargetGUID":"4d2340a5-3042-3630-3030-304a574a5250","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T09:33:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e55788193b7641ea9c26ad4ae15c77bc"}]},{"ProductId":"90a21d24fe854b07a035a8e7bf0e3602","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b59445a4b","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b59445a52","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b59445a54","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b59445a55","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b59445a48","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3533-364b59445a51","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b59445a4c","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b59445a4e","Version":"HPK1"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_Micron_7500_M7500ALLHPK1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b59445a50","Version":"HPK1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します: MO000800KYDZK、MO001600KYDZR、MO003200KYDZT、MO006400KYDZU、VO000960KYDZH、VO001920KYDZL、VO003840KYDZN、VO001536KYDZQ、VO007680KYDZP"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Changes and improvements made in HPK1 are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：<br />     </strong>HPK1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPK1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Changes and improvements made in HPK1 are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2256111","DateModified":"2024-04-24T04:35:15","FileList":["Micron_7500_Micron_7500_M7500ALLHPK1.HPb","Micron_7500_Micron_7500_M7500ALLHPK1.xml","payload.json"],"MD5Sum":"861573162c1915d9fba73550d82ed8fe","Name":"Micron_7500_Micron_7500_M7500ALLHPK1.fwpkg","Release":"2024-06-04T00:00:00","Revision":"","SHA1Sum":"b30a9dd549c0c527a638bdcdbe3d3cfcd4b3e63d","SHA256Sum":"46aeb5ac6f3b0acaf1d03687c838b2d49ed9b309226789972b031c909404b772","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b59445a4b","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3630-3430-304b59445a55","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3730-3638-304b59445a50"],"TypeOfChange":"1","Version":"HPK1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000800KYDZK、MO001600KYDZR、MO003200KYDZT、MO006400KYDZU、VO000960KYDZH、VO001920KYDZL、VO003840KYDZN、VO001536KYDZQ、VO007680KYDZP"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO006400KYDZU","TargetGUID":"4d2340a5-304f-3630-3430-304b59445a55","Type":"nvme"},{"Id":"MO003200KYDZT","TargetGUID":"4d2340a5-304f-3330-3230-304b59445a54","Type":"nvme"},{"Id":"MO001600KYDZR","TargetGUID":"4d2340a5-304f-3130-3630-304b59445a52","Type":"nvme"},{"Id":"MO000800KYDZK","TargetGUID":"4d2340a5-304f-3030-3830-304b59445a4b","Type":"nvme"},{"Id":"VO007680KYDZP","TargetGUID":"562340a5-304f-3730-3638-304b59445a50","Type":"nvme"},{"Id":"VO003840KYDZN","TargetGUID":"562340a5-304f-3330-3834-304b59445a4e","Type":"nvme"},{"Id":"VO001920KYDZL","TargetGUID":"562340a5-304f-3130-3932-304b59445a4c","Type":"nvme"},{"Id":"VO000960KYDZH","TargetGUID":"562340a5-304f-3030-3936-304b59445a48","Type":"nvme"},{"Id":"VO001536KYDZQ","TargetGUID":"562340a5-304f-3130-3533-364b59445a51","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-07T09:24:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"cn"}],"Version":"HPK1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPK1では、変更点および改善点として、Gen11 x2直接接続システムでドライブの内部PHYレジスタ値を変更することにより、受信信号を強化しています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Changes and improvements made in HPK1&nbsp;are to enhance receiver signals by changing the drive&rsquo;s internal PHY register values on Gen11 x2 direct attached system.</li></ul>","Lang":"cn"}],"Version":"HPK1"}],"SWKeys":[{"Name":"MO000800KYDZK","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KYDZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYDZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYDZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KYDZH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYDZL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYDZN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYDZP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001536KYDZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"738d3ecbd42b4b8d832987815cfae4d4"}]},{"ProductId":"7fe88b20c8c948e29d704473f3133fee","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33598813","DateModified":"2025-06-16T07:12:48","FileList":["payload.json","U50_2.42_06_13_2025.signed.flash","U50_2.42_06_13_2025.xml"],"MD5Sum":"97b6b362818d5eb9f50e2eaa3a91a929","Name":"U50_2.42_06_13_2025.fwpkg","Release":"2025-06-16T07:10:15","Revision":"","SHA1Sum":"37a79c5216d4ac3a99d2c8ce2ea928e2d0a76dc3","SHA256Sum":"7f3a41faabc00db8a6733dbda93a102b176116e7aad38126a1b18f479362168f","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:09:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"95a65967f82646d782c98dd904596bbb"}]},{"ProductId":"54856ac460a544e2985eadac24abf907","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGRTG9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM2000GEFRA"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM2000GEFRA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features&nbsp;for:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MM2000GEFRA Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br /><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features&nbsp;for:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3843688","DateModified":"2025-01-10T13:39:19","FileList":["cp065057.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVGRTG9.rel","setup.dll"],"MD5Sum":"75a1ecfded0a7bcc9a76da38ba7bae86","Name":"cp065057.exe","Release":"2025-01-10T13:35:35","Revision":"D","SHA1Sum":"d576e7561b9f6bc674cd573d52b767dd6ae6f719","SHA256Sum":"0d2d0c4a48d44249b4c4c2e859aa71827117d07f18f4f157bdaabb5193c5e81c","Size":"3MB","TargetGUIDs":["002340a5-4d00-324d-3030-304745465241"],"TypeOfChange":"1","Version":"HPG9"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM2000GEFRA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM2000GEFRAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM2000GEFRA","TargetGUID":"002340a5-4d00-324d-3030-304745465241","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:23:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG9"}],"SWKeys":[{"Name":"MM2000GEFRA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a56644069bc04f4091ec00136bf08f37"}]},{"ProductId":"b9dda486435f4c78a30de5b1c831c135","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3767400","DateModified":"2025-01-16T14:12:13","FileList":["cp065149.xml","cpqsetup.exe","Eaglescanyon-Release-0.39.bin.fw","payload.json","setup.dll"],"MD5Sum":"06b2c0593a489f2747103257b7e40297","Name":"cp065149.exe","Release":"2025-01-16T14:06:39","Revision":"E","SHA1Sum":"22f46d326ccff87cd2f466487a7982dbce5b6ecf","SHA256Sum":"db9c2ac8042af18af1d6e0325f1c8a418da2db2ccdeb920ceecec19c794fc75e","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p><ul><li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.aspx?version=\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-16T06:53:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support&nbsp;Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Microsoft Windows Server 2025をサポートします。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support&nbsp;Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<p>Support&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"da8ccf4d6e9b4059a21d60c802b20a3e"}]},{"ProductId":"660aa31b4e5e4c7fa47517faf21f93a1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB016000GWXKK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000GWXKK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19500510","DateModified":"2025-03-07T11:17:13","FileList":["/CP065948_BUILD_4.data","/CP065948.vmexe64","/CP065948.vmfile","/CP065948_VMw.zip","/CP065948.xml","/payload.json","/CP065948_VMw.zip/index.xml","/CP065948_VMw.zip/vendor-index.xml","/CP065948_VMw.zip/metadata.zip","/CP065948_VMw.zip/vib20/CP065948/HPE_bootbank_CP065948_HPG4.4-1OEM.800.1.0.20613240.vib","/CP065948_VMw.zip/metadata.zip/vendor-index.xml","/CP065948_VMw.zip/metadata.zip/vmware.xml","/CP065948_VMw.zip/metadata.zip/vibs/CP065948-5843835157085481538.xml","/CP065948_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065948_HPG4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"408d81d072da9ce24ddf32e0e5e32420","Name":"CP065948.zip","Release":"2025-03-07T11:16:24","Revision":"C","SHA1Sum":"9f9d347e952a2a5a343835bedcf135c8ea25ca0c","SHA256Sum":"9c7c9394a9a24cb9b21128af1b680f67c5f25852b93011fefed9aff19ac88782","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP065948","Version":"HPG4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000GWXKKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000GWXKK","TargetGUID":"4d2340a5-3042-3631-3030-304757584b4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:34:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f71d0aa764ae4c37b94b0a977af328e9"}]},{"ProductId":"260b73b77b824e60a7231a400ce24c25","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3906896","DateModified":"2025-01-11T09:53:22","FileList":["cp065079.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNTG6.rel","setup.dll"],"MD5Sum":"02b64bf895728d66b05112c66415d8d0","Name":"cp065079.exe","Release":"2025-01-11T09:48:56","Revision":"C","SHA1Sum":"3d9a74f6a0eb62e5c2c0cd905726add77f2f0845","SHA256Sum":"a53b88e3254710ba19dd8eacaaf7faa1bb25040e2142f5f2869b9f8ce0e3477d","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:19:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"15f5c75b81104174b2aabc9a5bfc68f5"}]},{"ProductId":"dcd60b858b6c4ac298dc49b61299aeb5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2022 and Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3129784","DateModified":"2025-02-13T07:54:22","FileList":["cp064340.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.65.23.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"9488405d5016a5801b414a851b6dd9aa","Name":"cp064340.exe","Release":"2025-02-13T07:45:48","Revision":"","SHA1Sum":"f88a8b072b72f3b73597d15c73a13691b3d6e979","SHA256Sum":"8b320da24427dc857a85b7722c6e591d2b53e73246e8a115cacc5cce08a53681","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"5.3.7.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR><P>From that drive and directory, execute the downloaded file. <BR><P>Click the \"Install\" button to proceed with the installation.</P><P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<BR><P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR><P>［インストール］ボタンをクリックして、インストールを開始します。</P><P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"5.3.6.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.3.7.0"}],"SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"37f4e45347274f90b807bba74f66b67f"}]},{"ProductId":"9fd1abd8973f4c09aa450e541dc4ee41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p><ul><li>Fix for unrecovered errors which may occur on the targeted Blocks of Wear-leveling process when host issues Read command.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5604360","DateModified":"2025-05-14T06:24:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/CP066535.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066535.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066535.scexe"],"MD5Sum":"d1dcb60b2edaa30277efe3ebc0733f67","Name":"firmware-hdd-8fafc9efb2-HPD8-4.1.x86_64.rpm","Release":"2025-05-14T10:58:08","Revision":"D","SHA1Sum":"bf66ed9df34a3d28ef2ddab7384b1850b048b4da","SHA256Sum":"70f627236a878fb1dd50ec4bc5c0608d67a3b8041f104ccccceb57564c13b554","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041555.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO007680RWUFC","TargetGUID":"562340a5-304f-3730-3638-305257554643","Type":"sas"},{"Id":"VO003840RWUFF","TargetGUID":"562340a5-304f-3330-3834-305257554646","Type":"sas"},{"Id":"VO003840RWUFB","TargetGUID":"562340a5-304f-3330-3834-305257554642","Type":"sas"},{"Id":"VO001920RWUFE","TargetGUID":"562340a5-304f-3130-3932-305257554645","Type":"sas"},{"Id":"VO001920RWUFA","TargetGUID":"562340a5-304f-3130-3932-305257554641","Type":"sas"},{"Id":"VO000960RWUFD","TargetGUID":"562340a5-304f-3030-3936-305257554644","Type":"sas"},{"Id":"VO000960RWUEV","TargetGUID":"562340a5-304f-3030-3936-305257554556","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:12:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"47b6d734ca17469da8d7f53f8ed57529"}]},{"ProductId":"a08198f75ae64d5f81f313aee3e10a81","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p53_CFGID7p2_K97342_8000F8E2.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3755.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p53_CFGID7p2_K97470_8000F8EE.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, vSphere 8.0 and vSphere 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, vSphere 8.0 and vSphere 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, vSphere 8.0 and vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"6585120","DateModified":"2025-04-01T08:32:31","FileList":["/CP065266_BUILD_22.data","/CP065266_VMw.zip","/CP065266.xml","/payload.json","/CP065266_VMw.zip/index.xml","/CP065266_VMw.zip/vendor-index.xml","/CP065266_VMw.zip/metadata.zip","/CP065266_VMw.zip/vib20/CP065266/HPE_bootbank_CP065266_3.26.1.22-8.0.0.20613240.vib","/CP065266_VMw.zip/metadata.zip/vendor-index.xml","/CP065266_VMw.zip/metadata.zip/vmware.xml","/CP065266_VMw.zip/metadata.zip/vibs/CP065266-763674270390408393.xml","/CP065266_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065266_3.26.1.22-8.0.0.20613240.xml"],"MD5Sum":"61f11178f44823884f392f174c4bd171","Name":"CP065266.zip","Release":"2025-04-01T08:31:58","Revision":"B","SHA1Sum":"252e9cc258f19d56cd68399afe0fb645155b108b","SHA256Sum":"7c0483847e23399617e2adb0a0904b363c41befbbe42242adbdae8e356b7f8ce","Size":"6MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"3.26.1","VibList":[{"Name":"CP065266","Version":"3.26.1.22-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Online Firmware Upgrade Utility for VMware "},{"Lang":"ja","Value":"Intelオンラインファームウェアアップグレードユーティリティfor VMware "},{"Lang":"cn","Value":"Intel Online Firmware Upgrade Utility for VMware "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:21:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product now supports VMware 9.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、現在VMware 9.0をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports VMware 9.0</p>","Fixes":"","Lang":"cn"}],"Version":"3.25.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"3.26.1"}],"SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9e01a07a1e5a426e961dc7a6cfce916a"}]},{"ProductId":"64511cd7ad8d42fea109336ca7a083a0","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 8.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 8.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"30833489","DateModified":"2025-06-16T12:12:24","FileList":["/CP067552.vmexe64","/CP067552.vmfile","/CP067552.xml","/CP067552_VMw.zip","/payload.json","/CP067552_VMw.zip/index.xml","/CP067552_VMw.zip/vendor-index.xml","/CP067552_VMw.zip/metadata.zip","/CP067552_VMw.zip/vib20/CP067552/HPE_bootbank_CP067552_1.0.0-8.0.0.21495797.vib","/CP067552_VMw.zip/metadata.zip/vendor-index.xml","/CP067552_VMw.zip/metadata.zip/vmware.xml","/CP067552_VMw.zip/metadata.zip/vibs/CP067552-4589084990299190335.xml","/CP067552_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067552_1.0.0-8.0.0.21495797.xml"],"MD5Sum":"ec892c27a830f65363c47ddfc07d9ad7","Name":"CP067552.zip","Release":"2025-06-16T12:29:04","Revision":"","SHA1Sum":"a4bee88e686b32f0dc2b30a96215fc1954b1edae","SHA256Sum":"45b1634d5f05e6d27589992d19a60caa64a46d3559fd6e62d4c2757885557274","Size":"29MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.8","VibList":[{"Name":"CP067552","Version":"1.0.0-8.0.0.21495797"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T11:51:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2026にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"1.0.7"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.8"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5397303bc0924471a4fb13298ee68845"}]},{"ProductId":"5e23a12643374784bca02e8442853ff7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4350672","DateModified":"2025-01-11T11:57:12","FileList":["cp063922.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPSD3.rel"],"MD5Sum":"0978f508b0594b5cbb969549b91b1f8f","Name":"cp063922.exe","Release":"2025-01-11T11:52:21","Revision":"C","SHA1Sum":"5806f24b4e372546882a92be5260287c3b27a29b","SHA256Sum":"2e9380ae1041f65bfdca2db36eb1f13ba31399998bc6f425731384310e523cfb","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-10T11:24:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"03c3e74c021b40b2a14f0c5cbbbd4f1c"}]},{"ProductId":"1d14b3fb06db4e8a9306176914f7f80d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWUEA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57554541","Version":"HPK3"},{"DeviceName":"VO001920KWUEB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57554542","Version":"HPK3"},{"DeviceName":"VO003840KWUEC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57554543","Version":"HPK3"},{"DeviceName":"VO007680KWUED","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57554544","Version":"HPK3"},{"DeviceName":"VO015360KWUEE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b57554545","Version":"HPK3"},{"DeviceName":"MO000800KWUDR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b57554452","Version":"HPK3"},{"DeviceName":"MO001600KWUDT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57554454","Version":"HPK3"},{"DeviceName":"MO003200KWUDU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57554455","Version":"HPK3"},{"DeviceName":"MO006400KWUDV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57554456","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following NVMe drive models: VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDU、MO006400KWUDVドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p style=\"text-align:left\"><strong>Known Issues:</strong></p><p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p style=\"text-align:left\"><strong>Known Issues:</strong></p><p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5758009","DateModified":"2025-05-14T06:47:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/CP066547.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/KACM5ALSHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-726d5ec795-HPK3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066547.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066547.scexe"],"MD5Sum":"51b39ed68b7f28f3bffbc7b1e77b135a","Name":"firmware-hdd-726d5ec795-HPK3-5.1.x86_64.rpm","Release":"2025-05-14T11:35:04","Revision":"E","SHA1Sum":"b1aa0b58bfe1dc8e87457c0ff049bd48745dfeed","SHA256Sum":"70c157d5ed025a18bb00d7ef8a305effa912c58033b97d18681ff2c15bc17c5a","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304b57554541","562340a5-304f-3130-3932-304b57554542","562340a5-304f-3330-3834-304b57554543","562340a5-304f-3730-3638-304b57554544","562340a5-304f-3531-3336-304b57554545","4d2340a5-304f-3030-3830-304b57554452","4d2340a5-304f-3130-3630-304b57554454","4d2340a5-304f-3330-3230-304b57554455","4d2340a5-304f-3630-3430-304b57554456"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"CP041863.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p><p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p><p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン:</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KWUEA, VO001920KWUEB, VO003840KWUEC, VO007680KWUED, VO015360KWUEE, MO000800KWUDR, MO001600KWUDT, MO003200KWUDU and MO006400KWUDV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KWUEA、VO001920KWUEB、VO003840KWUEC、VO007680KWUED、VO015360KWUEE、MO000800KWUDR、MO001600KWUDT、MO003200KWUDU、MO006400KWUDVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO000960KWUEA","TargetGUID":"562340a5-304f-3030-3936-304b57554541","Type":"nvme"},{"Id":"VO001920KWUEB","TargetGUID":"562340a5-304f-3130-3932-304b57554542","Type":"nvme"},{"Id":"VO003840KWUEC","TargetGUID":"562340a5-304f-3330-3834-304b57554543","Type":"nvme"},{"Id":"VO007680KWUED","TargetGUID":"562340a5-304f-3730-3638-304b57554544","Type":"nvme"},{"Id":"VO015360KWUEE","TargetGUID":"562340a5-304f-3531-3336-304b57554545","Type":"nvme"},{"Id":"MO000800KWUDR","TargetGUID":"4d2340a5-304f-3030-3830-304b57554452","Type":"nvme"},{"Id":"MO001600KWUDT","TargetGUID":"4d2340a5-304f-3130-3630-304b57554454","Type":"nvme"},{"Id":"MO003200KWUDU","TargetGUID":"4d2340a5-304f-3330-3230-304b57554455","Type":"nvme"},{"Id":"MO006400KWUDV","TargetGUID":"4d2340a5-304f-3630-3430-304b57554456","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T13:54:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWUEA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWUEB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWUEC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KWUED","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KWUEE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KWUDR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWUDT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWUDU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWUDV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"de84cd483dce4e64ac53b30e6f3f6f77"}]},{"ProductId":"17ae190412f049ff80b7f941eb9e3732","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33595852","DateModified":"2025-05-21T12:43:18","FileList":["A46_3.72_05_16_2025.signed.flash","A46_3.72_05_16_2025.xml","payload.json"],"MD5Sum":"29606d8a93cb8300e93ec5f655cb86e3","Name":"A46_3.72_05_16_2025.fwpkg","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"5387ddafbfab73476937e6b0b89703afd7e842cf","SHA256Sum":"58a7e42925e9a474ebe0fe05967ca5cb83a3677592e2dec6c234c7e388c50626","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"96a88056b00f4e43bdf0c62c849c201e"}]},{"ProductId":"fc90f99dec3d4432a73ac738a336cdc1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7407761","DateModified":"2025-07-29T06:51:06","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/21","./usr/lib/.build-id/21/79776695b0e7b150e5cc6039b2b418697897f8","./usr/lib/.build-id/21/79776695b0e7b150e5cc6039b2b418697897f8.1","./usr/lib/.build-id/26","./usr/lib/.build-id/26/52eedaa7c0629ae317efe3c838fc88b76a406f","./usr/lib/.build-id/26/52eedaa7c0629ae317efe3c838fc88b76a406f.1","./usr/lib/.build-id/44","./usr/lib/.build-id/44/2fd4fe878bb78b501c132f3a3526f668d7a9b0","./usr/lib/.build-id/44/2fd4fe878bb78b501c132f3a3526f668d7a9b0.1","./usr/lib/.build-id/95","./usr/lib/.build-id/95/73e777fc5cae7e45111c2c96efdb1c4af9f1ff","./usr/lib/.build-id/98","./usr/lib/.build-id/98/d1b5b04506a603da4653a2e7ec11d5e57fe6c6","./usr/lib/.build-id/98/d1b5b04506a603da4653a2e7ec11d5e57fe6c6.1","./usr/lib/.build-id/a6","./usr/lib/.build-id/a6/6e84ebbffd1bbdfb7786ef34f3b62ee5c489a3","./usr/lib/.build-id/a6/6e84ebbffd1bbdfb7786ef34f3b62ee5c489a3.1","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/8c62d32dad0ba9223de34dc9901cd82ecb4bf0","./usr/lib/.build-id/c0/8c62d32dad0ba9223de34dc9901cd82ecb4bf0.1","./usr/lib/.build-id/ce","./usr/lib/.build-id/ce/000544ca560294309b6df867360fde398d6f8e","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/14b461d2c962ee121d541d4f5bd636e473173c","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"9aaf680e2a42c341f43be92acd529e6a","Name":"amsd-4.2.0-2039.8.rhel10.x86_64.rpm","Release":"2025-07-29T11:46:07","Revision":"","SHA1Sum":"fc02f3b2eb67327a883b13e4239e9cf9d0888b97","SHA256Sum":"6d84f3ed6b78d2d2acd99c95661464625de255b3639f6140a3de1c997239bbc2","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.2.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 10 Server"},{"Lang":"ja","Value":"Agentless Management Service (iLO 5、iLO 6およびiLO 7) for Red Hat Enterprise Linux 10 Server"},{"Lang":"cn","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 10 Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T10:05:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.1.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.2.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2a3799c1b42e45c0a52cfe294c20cbe2"}]},{"ProductId":"e528a2af212b4bb09bfd3cb54b985653","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5093197","DateModified":"2025-05-14T06:56:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/CP066642.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066642.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066642.scexe"],"MD5Sum":"ca0c950d4d16f0f9d609b1c4505ce054","Name":"firmware-smartarray-f36d4ef431-0.39-7.1.x86_64.rpm","Release":"2025-05-14T11:44:05","Revision":"G","SHA1Sum":"6d72d62ea2cc4259a45a7c3bb7471fb8887082fe","SHA256Sum":"21c1779c778c3d48f2f97c9a0ddbbd4b57d5c73ef0a7e1fe5e69eacdf0ec7ffb","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"Installation":{"Command":"CP066642.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p><p><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPPxxxxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-02T02:24:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"958d8f91bb5d41cd9d929ecdf1576fd8"}]},{"ProductId":"e8a7c3696813408f916249b859b6b722","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following SATA drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes an intermittent issue where the incorrect model number can be reported during spin-up.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5696489","DateModified":"2025-05-14T07:47:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/CP066499.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/SAVGNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066499.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066499.scexe"],"MD5Sum":"beab68ee01dd3b93282f8b9c3ce2195f","Name":"firmware-hdd-95af9a555e-HPG6-6.1.x86_64.rpm","Release":"2025-05-14T12:34:22","Revision":"F","SHA1Sum":"af8854d2bcb32f5c50d1c389fe8e23695beaa6aa","SHA256Sum":"80ea2b21481b9d2b75dc9b5f5a8e7b3703342c7e8f0e8a1ab45fc17124c72231","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP040344.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T17:41:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b945c98a835b499e8f68dafbb0b7a039"}]},{"ProductId":"170e9646d84b43c984c43d017aedc665","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33612948","DateModified":"2025-04-18T12:28:55","FileList":["payload.json","U34_3.50_04_17_2025.signed.flash","U34_3.50_04_17_2025.xml"],"MD5Sum":"c0fedd9e0d08e7c5a7fcb95a3fcb7ad2","Name":"U34_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"42b8f9adf0ec53eef3ca22f59d6835c1d032aadf","SHA256Sum":"a0e91ba0f889d40cffb1df8d1a3532d2bbcebb04d7b5471bd987714bf6f3da90","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"50dbd5a98a4e49109f996810bc3a916f"}]},{"ProductId":"e5d8389759aa4832a8475a2ff763f16b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Reommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Reommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3441736","DateModified":"2025-01-11T07:20:22","FileList":["cp065070.xml","cpqsetup.exe","GPM1643ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"49f94256b4c0114e3cf031e8fb613ba2","Name":"cp065070.exe","Release":"2025-01-11T07:15:38","Revision":"C","SHA1Sum":"7b297c219e9b27955795ee112d0e89ebea1d1346","SHA256Sum":"48c38374f635e7937633c28fd5a777002fa830fb7f4a5bfc345e66793a5a3a8c","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:38:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dc8a95ccb989492b910a7a8f79e83bc3"}]},{"ProductId":"575b91de95af482eb3a08ed94402e2c3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUASG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3432-3030-30475945564b","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB24000GYEVK"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB24000GYEVK"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB24000GYEVK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; FW assert fix and other regular maintenance release.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3294480","DateModified":"2024-10-25T07:57:21","FileList":["payload.json","Seagate_Summit_SUMMITSUASG1.HPb","Seagate_Summit_SUMMITSUASG1.xml"],"MD5Sum":"781c1a56c20ac0769586fded47d59180","Name":"Seagate_Summit_SUMMITSUASG1.fwpkg","Release":"2024-10-25T07:55:19","Revision":"","SHA1Sum":"75b1ded20aa896a35f0dbd57b2847c586030963e","SHA256Sum":"13d8c5df5e9044081ad690380aa1de044c4a4e0d627b3ee3174321c58f1fdff5","Size":"3MB","TargetGUIDs":["002340a5-424d-3432-3030-30475945564b"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB24000GYEVK"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MB24000GYEVK"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB24000GYEVK"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB24000GYEVK","TargetGUID":"002340a5-424d-3432-3030-30475945564b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-25T06:15:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>FW assert fix and other regular maintenance release.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB24000GYEVK","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"675c69d416134f789231a11d446f13a9"}]},{"ProductId":"66cb80b1d5d040ff8edbcf313b0e2f9d","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAnD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a575a5655","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB004000JWZVU"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB004000JWZVU"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB004000JWZVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; N/A</strong><br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"1290647","DateModified":"2025-02-19T20:47:20","FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAnD3.HPb","Toshiba_MG08Air_TAMG08SDAnD3.xml"],"MD5Sum":"36ff098bf468f4587388f9c032120ee3","Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","Release":"2025-02-19T20:45:01","Revision":"B","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a575a5655"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB004000JWZVU"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ -  MB004000JWZVU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB004000JWZVU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB004000JWZVU","TargetGUID":"4d2340a5-3042-3430-3030-304a575a5655","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T21:03:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p>&nbsp;</p>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul><p> </p>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p>&nbsp;</p>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB004000JWZVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"cb947df2b7494b02a1ae11bb036e5d53"}]},{"ProductId":"7a882d320d3b437c96a87679f2b6ee8f","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.01"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.01"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.01"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.01"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6901558","DateModified":"2025-07-04T09:13:20","FileList":["/CP067636_BUILD_1.data","/CP067636.vmexe","/CP067636.vmexe64","/CP067636.vmfile","/CP067636_VMw.zip","/CP067636.xml","/payload.json","/CP067636_VMw.zip/index.xml","/CP067636_VMw.zip/vendor-index.xml","/CP067636_VMw.zip/metadata.zip","/CP067636_VMw.zip/vib20/CP067636/HPE_bootbank_CP067636_CP067636.1-1OEM.900.0.24580437.vib","/CP067636_VMw.zip/metadata.zip/vendor-index.xml","/CP067636_VMw.zip/metadata.zip/vmware.xml","/CP067636_VMw.zip/metadata.zip/vibs/CP067636-7268741696145478916.xml","/CP067636_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067636_CP067636.1-1OEM.900.0.24580437.xml"],"MD5Sum":"3e03051ebbbbf9456a82426d4dd0ca89","Name":"CP067636.zip","Release":"2025-07-04T09:09:18","Revision":"","SHA1Sum":"6037a02d3af18f3c811e802681fa6b2f0a531afa","SHA256Sum":"1c20e64acc07ef003c2db579cccbd82b10f14101b9ace9b0f1f22a674cf79843","Size":"6MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.05.02","VibList":[{"Name":"CP067636","Version":"CP067636.1-1OEM.900.0.24580437"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用する場合：</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 9.0"},{"Lang":"ja","Value":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 9.0用HPEファームウェアフラッシュ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-24T08:56:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.02"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"895b3c616f16488f9f137a19d5550aca"}]},{"ProductId":"8dad994cacb24e87b613f12e36f4c8c5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 64-bit support for HPE Smart Array MR controllers"},{"Lang":"ja","Value":"このドライバーMegaSAS35は、HPE SmartアレイMRコントローラー用のWindows 64-bitサポートを提供します"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"892600","DateModified":"2022-09-30T07:35:10","FileList":["cp054321.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"3dbe7b9ba0ccca4bb61cc44f9b54c955","Name":"cp054321.exe","Release":"2022-09-30T07:32:42","Revision":"D","SHA1Sum":"426d3730acdafe37cc0a687aaa789ec25245d494","SHA256Sum":"efa1f49aae58b8506f67d1ba7274d2f1acafd27faeaf39110644fe9926f3e76f","Size":"871KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.716.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p,MR416i-a, MR216i-p, MR216i-a 64-bit controller driver for Microsoft Windows 2016 edition."},{"Lang":"ja","Value":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a 64-bitコントローラードライバーfor Microsoft Windows 2016 edition。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2022-10-07T19:38:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"cn"}],"Version":"7.716.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support SHA384</p>","Fixes":"","Lang":"cn"}],"Version":"7.716.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ecf8cab070b24650ba98c6d26cb25ed0"}]},{"ProductId":"b75caf763a204707bef1840fcde5be6a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."},{"Lang":"ja","Value":"このコンポーネントは、Microchip/Microsemi PCIe Gen4スイッチのドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"567752","DateModified":"2024-03-18T16:19:16","FileList":["cp060555.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"MD5Sum":"028edff2c3575f1eb38e149c3fe191c3","Name":"cp060555.exe","Release":"2024-03-18T16:17:06","Revision":"B","SHA1Sum":"b0458b47c4a90cbc0bfde1ba079a742ad8f13b6b","SHA256Sum":"f9803e08e077f036b81b1f222918aac03d7b5a022b066f5b40f2effe4fcf3418","Size":"554KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<br />インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。<br />インストールボタンをクリックしてドライバーインストールを実行します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Microsoft Windows Server 2022用のSwitchtec PCIeスイッチ管理ドライバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedDevices":[{"Dev":"4000","SubDev":"4000","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-400011f84000","Type":"pci","Ven":"11F8"},{"Dev":"4052","SubDev":"4052","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-405211f84052","Type":"pci","Ven":"11F8"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-04-18T16:03:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update version</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>アップデートバージョン</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update version</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"}],"SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7326920731fb4fbe8fc5c1297853e3f2"}]},{"ProductId":"cc96bd351eff4426bf37f3da741a7623","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB004000GWKGV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWKGV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20603112","DateModified":"2025-03-06T16:46:27","FileList":["/CP065987_BUILD_3.data","/CP065987.vmexe64","/CP065987.vmfile","/CP065987_VMw.zip","/CP065987.xml","/payload.json","/CP065987_VMw.zip/index.xml","/CP065987_VMw.zip/vendor-index.xml","/CP065987_VMw.zip/metadata.zip","/CP065987_VMw.zip/vib20/CP065987/HPE_bootbank_CP065987_HPG1.3-1OEM.800.1.0.20613240.vib","/CP065987_VMw.zip/metadata.zip/vendor-index.xml","/CP065987_VMw.zip/metadata.zip/vmware.xml","/CP065987_VMw.zip/metadata.zip/vibs/CP065987-2652008018376451013.xml","/CP065987_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065987_HPG1.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5cd504e016a9b599a0efd88001cfc5d1","Name":"CP065987.zip","Release":"2025-03-06T16:45:43","Revision":"K","SHA1Sum":"ed881d89631edd69c1afa5257bd5b5c0cdd76ed8","SHA256Sum":"762a7c29e6eea34db2bcb008f2c7ad3a6d91de0466b3a922aaf4a53b0a2c0db3","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065987","Version":"HPG1.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041493.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000GWKGVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWKGV","TargetGUID":"4d2340a5-3042-3430-3030-3047574b4756","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:34:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2e372effed5940ee9e19594f3202980c"}]},{"ProductId":"dc41774861a945f28d388059e656b2ca","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_OCP_4p71_NCSIwPLDMoMCTP_80020036.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-CQDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80020036</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター</td><td>80020036</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td><td>80020036</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524635","DateModified":"2025-04-01T03:33:19","FileList":["HPE_E810_CQDA2_OCP_4p71_NCSIwPLDMoMCTP_80020036.HPb","HPE_E810_CQDA2_OCP_4p71_NCSIwPLDMoMCTP_80020036.xml","payload.json"],"MD5Sum":"0638ca3115c6af0bee0c929c94c429d9","Name":"HPE_E810_CQDA2_OCP_4p71_NCSIwPLDMoMCTP_80020036.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"90eef370f43464d51a6b913ce3e94c5a87ebcafc","SHA256Sum":"5c251874515ad56d45fd635846de05fcdfa7e7b9f6a7e61ba71010f495edbb29","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:36:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6177a06c1b2c4c6ab5c51b78fd9f2509"}]},{"ProductId":"0f2b8614c6ab40aea6c15cd633ff1402","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18843809","DateModified":"2025-03-06T10:53:00","FileList":["/CP065995_BUILD_2.data","/CP065995.vmexe64","/CP065995.vmfile","/CP065995_VMw.zip","/CP065995.xml","/payload.json","/CP065995_VMw.zip/index.xml","/CP065995_VMw.zip/vendor-index.xml","/CP065995_VMw.zip/metadata.zip","/CP065995_VMw.zip/vib20/CP065995/HPE_bootbank_CP065995_HPG1.2-1OEM.800.1.0.20613240.vib","/CP065995_VMw.zip/metadata.zip/vendor-index.xml","/CP065995_VMw.zip/metadata.zip/vmware.xml","/CP065995_VMw.zip/metadata.zip/vibs/CP065995--7969129075819612975.xml","/CP065995_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065995_HPG1.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"a00accef6240fc0e9dd765b5b4ae6248","Name":"CP065995.zip","Release":"2025-03-06T10:52:13","Revision":"K","SHA1Sum":"4be86ef24938cc396257bee3c50fea78b26cc36c","SHA256Sum":"7847597d43089fa4b2c97a2768321327e8bf38003dfb1cc1c7e18ed5460df2ab","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065995","Version":"HPG1.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040691.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:23:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fff860ffbd24a8098156de57480237f"}]},{"ProductId":"7a38c76de8ff4383970907d2998b1740","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1033712","DateModified":"2024-06-13T04:42:19","FileList":["cp061745.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"MD5Sum":"3ed3318f05b80e29bd9abb513e069c6e","Name":"cp061745.exe","Release":"2024-06-13T04:27:04","Revision":"","SHA1Sum":"444b04660f080cb913c90d57a0a409f88e207650","SHA256Sum":"84a5c6ec4cb8de4b93c2d1589e963a5dd2579c1155eacbf987df6d766ebdb7ba","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixn Driver for Windows Server 2019"},{"Lang":"ja","Value":"HPE Intel ixnドライバー for Windows Server 2019"},{"Lang":"cn","Value":"HPE Intel ixn Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-12T07:20:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the new firmware.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.251.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"301e079f71814412bbc686a6a7b00750"}]},{"ProductId":"421cc08cc7bc4143866089180c719d3f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JWDFD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Mitigates the potential drive FW halt issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Mitigates the potential drive FW halt issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6310432","DateModified":"2025-05-14T08:54:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/CP066536.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/WLEAsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066536.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066536.scexe"],"MD5Sum":"7dc29495b9f875fde720f456afa089a9","Name":"firmware-hdd-aaf1014ede-HPD4-4.1.x86_64.rpm","Release":"2025-05-14T13:43:04","Revision":"D","SHA1Sum":"4071cee497389de3a47a44cf8e3963121c7e7a7c","SHA256Sum":"5dee447f130a41ef14eb7208e8d5d331b94a714e737c593ad20f1aebf1944181","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040338.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000JWDFDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000JWDFD","TargetGUID":"4d2340a5-3042-3231-3030-304a57444644","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:26:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ce0c8b931dc944eba16ec625f8c05959"}]},{"ProductId":"52c884546e0a44fb8cddfd654ad71e81","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17125002","DateModified":"2025-05-20T21:51:12","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/CP067165.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/U60_2.40_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.40_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067165.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067165.scexe"],"MD5Sum":"16803f7c4e63b6723dfe0c16690d919b","Name":"firmware-system-u60-2.40_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-21T02:41:42","Revision":"","SHA1Sum":"587a2259c89adadc4544405e840f43bb56b18da4","SHA256Sum":"a78fe1de28ece7d6b1938d8dfbf51c840fdb69396b7d132257cc590ce4ff24c5","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL20 Gen10 Plus サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:32:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c6ae859b972e4052b9275806e29e42c2"}]},{"ProductId":"e33bb1d2f7324af98ab1d5f7897ec4b5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2022用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2341472","DateModified":"2025-03-25T09:15:20","FileList":["cp066449.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"1de85bf39ce7968531a6a7fd04af9885","Name":"cp066449.exe","Release":"2025-03-25T09:00:55","Revision":"","SHA1Sum":"aa9ddeb09cd9605de357f28995ad671b21fba240","SHA256Sum":"223487eed737671f0d2ea65345cca82982cfa6dfd19d72357b628dd83b9f6244","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"f9274c317c5d4c95adf53aaddcd99bb3"}]},{"ProductId":"d6cef3e7c9484a989ca5a04fc11b29f2","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"219887","DateModified":"2025-05-15T01:26:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/CP067251.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/PICGen10_v1.1.4_hdr.signed.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067251.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067251.scexe"],"MD5Sum":"ac71d994f5fe2e1f8a9c2b303eb59a66","Name":"firmware-powerpic-gen10-1.1.4-6.1.x86_64.rpm","Release":"2025-05-15T06:19:17","Revision":"F","SHA1Sum":"fce989e828dd691e8ac5366dd7952e1dcc3dc26d","SHA256Sum":"dd76a2998abd8ee10aa1ce8da086d6014675f4914e67eac4f10e3d506585876c","Size":"214KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュ for Linux - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 PlusおよびML30 Gen11サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T06:14:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>Ver. 1.1.4(E) contains updates to the firmware packaging and is functionally equivalent to ver. 1.1.4. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 1.1.4.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意:</strong></p><p>Ver 1.1.4(E)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver  1.1.4. ファームウェアをバージョン1.1.4にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンEにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>Ver. 1.1.4(E) contains updates to the firmware packaging and is functionally equivalent to ver. 1.1.4. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 1.1.4.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DX360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e17dcb3b519845f7b31f35d0fd0ee576"}]},{"ProductId":"6d4e51e8b4c040cc80275ae447831403","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P ,Gen11 and Gen12 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P ,Gen11 and Gen12 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10P ,Gen11 and Gen12 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3120464","DateModified":"2025-06-03T14:14:19","FileList":["cp064824.xml","cpqsetup.exe","cp_data.xml","install.xml","multisetup.dll","StorCLI.msi"],"MD5Sum":"219bcb4f7474ec3036c37408c59df6ca","Name":"cp064824.exe","Release":"2025-06-03T14:11:36","Revision":"C","SHA1Sum":"54c7287caf81ce4bb7efe3c3107a74e1e83bcaa3","SHA256Sum":"d51aad347195134a8ac84e7420b6e6ea1b1f640a721b654ccdcd3fafea4ac708","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"TypeOfChange":"1","Version":"7.3210.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p><p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>"},{"Lang":"ja","Value":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p><p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>"},{"Lang":"cn","Value":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p><p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.3011.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"cn"}],"Version":"7.3210.0.0"}],"SWKeys":[{"Name":"storcli64.exe","SWKeyExpectedPath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7fbb1bdc104742a299d7ad41138dc31a"}]},{"ProductId":"261c2f9a8f584fd69c7ae5c1643322e4","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF,V K001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"16649800","DateModified":"2025-03-06T11:10:39","FileList":["/CP065971_BUILD_13.data","/CP065971.vmexe64","/CP065971.vmfile","/CP065971_VMw.zip","/CP065971.xml","/payload.json","/CP065971_VMw.zip/index.xml","/CP065971_VMw.zip/vendor-index.xml","/CP065971_VMw.zip/metadata.zip","/CP065971_VMw.zip/vib20/CP065971/HPE_bootbank_CP065971_HPG5.13-8.0.0.20613240.vib","/CP065971_VMw.zip/metadata.zip/vendor-index.xml","/CP065971_VMw.zip/metadata.zip/vmware.xml","/CP065971_VMw.zip/metadata.zip/vibs/CP065971--7373643190641160641.xml","/CP065971_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065971_HPG5.13-8.0.0.20613240.xml"],"MD5Sum":"6b95fffbb63e29b1240e054fdf497251","Name":"CP065971.zip","Release":"2025-03-06T11:09:51","Revision":"J","SHA1Sum":"3479f3079ebe99841d2ed0a6837124cf16fa7e14","SHA256Sum":"fed8e9fef663c7702dd17aa56e5c2c9230b005d9c19b9c2e3eed0a0b3bd122fb","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP065971","Version":"HPG5.13-8.0.0.20613240"}]}],"Installation":{"Command":"CP042736.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:44:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5bda8aab3a0f4794810c9b2b92732953"}]},{"ProductId":"5f7dae044b3b4d97823b1cfc69305837","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v7.19.27&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>UEFI Version</strong></td><td><strong>iSCSI Version</strong></td><td><strong>FCoE Version</strong></td><td><strong>CCM Version</strong></td><td><strong>L2 Version</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 530SFP+ Adapter<br />HPE Ethernet 10Gb 2-port 530T Adapter</td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>n/a</td><td>n/a</td><td>7.14.4</td><td>7.12.25</td></tr><tr><td><p>HPE Ethernet 10Gb 2-port 533FLR-T Adapter<br />HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />HPE FlexFabric 10Gb 4-port 536FLR-T Adapter</p></td><td>7.16.15</td><td>7.14.13</td><td>8.9.3</td><td>7.14.0</td><td>7.14.3</td><td>7.14.4</td><td>7.12.25</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"3279090","DateModified":"2024-12-11T03:26:28","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/CP064333.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/nic_fw/hp_mbi_7.19.27.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.37.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064333.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064333.scexe"],"MD5Sum":"3c205ad09bbb41cdfb3eb86e1c91cbb6","Name":"firmware-nic-qlogic-nx2-2.37.0-1.1.x86_64.rpm","Release":"2024-12-11T09:18:57","Revision":"","SHA1Sum":"90068aa562bf394f76ab6fa8ec346bb0e3a326c0","SHA256Sum":"e384f4928f9eaebe951691a70ef7285fcd9eb472087f3e12b108311f188e5c7e","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"2.37.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"适用于 Linux x86_64 的 HPE QLogic NX2 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T03:48:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixed to prevent BSOD issue.</p>","Lang":"cn"}],"Version":"2.36.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.37.0"}],"SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"67291762a5054079aef09cf140b67273"}]},{"ProductId":"9a74de9c33bb4afeafe66492b230f37e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"584208","DateModified":"2025-07-03T09:41:14","FileList":["cp067694.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"284f19df77adea9de925957f58e9ff73","Name":"cp067694.exe","Release":"2025-07-03T09:39:40","Revision":"B","SHA1Sum":"c6677f8b68c144eec889f23662df766b9f9c6314","SHA256Sum":"5575ce20d874fd34410f62274f5e3c1e4b70935d34123430c3d0d0846e2bbd05","Size":"570KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーfor Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-01T09:06:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li><li>サポートされるプラットフォームをアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li><li>Updated supported platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\necheschif.inf_amd64_e49bd7dc444fc00f"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3f85cd35cf90442f80873947db78ad39"}]},{"ProductId":"f85aacf9018c4fbdadcdb2b9bbf03fed","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584e5845","Version":"HPK4"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-304b584e5a55","Version":"HPK4"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3053-3130-3932-304b584e5846","Version":"HPK4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します:"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp; &nbsp; &nbsp;Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：</strong><br />     HPK4<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPK1<br /><strong>前のファームウェアバージョン：</strong><br />     HPK1<br /><strong>機能強化/新しい機能：</strong><br />     なし<br /><strong>修正された問題:</strong><br />     ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりもPCIe VDM上のMCTPが無効になります。</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp; &nbsp; &nbsp;Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2385020","DateModified":"2024-10-08T11:08:14","FileList":["Micron_7450_M7450ALLHPK4.HPb","Micron_7450_M7450ALLHPK4.xml","payload.json"],"MD5Sum":"f3ad8c9c23aa5389ec6f1a0bba7f00ca","Name":"Micron_7450_M7450ALLHPK4.fwpkg","Release":"2024-10-28T00:00:00","Revision":"","SHA1Sum":"f535fc8adfc20c73163cf5e5c2d97a7455156995","SHA256Sum":"7212abcb9de057f2c3fd7c87b8fe038846875b91c34cd56ef6679a09c9452edb","Size":"2MB","TargetGUIDs":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"TypeOfChange":"1","Version":"HPK4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":" Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"},{"Lang":"ja","Value":" ユニバーサルファームウェアパッケージforドライブ - VR000480KXNXE、VR000960KXNZU、およびVS001920KXNXF"},{"Lang":"cn","Value":" Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000480KXNXE","TargetGUID":"562340a5-3052-3030-3438-304b584e5845","Type":"nvme"},{"Id":"VR000960KXNZU","TargetGUID":"562340a5-3052-3030-3936-304b584e5a55","Type":"nvme"},{"Id":"VS001920KXNXF","TargetGUID":"562340a5-3053-3130-3932-304b584e5846","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-04T09:44:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりも PCIe VDM上のMCTPが無効になります。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"cn"}],"Version":"HPK4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>ファームウェアHPK4で行われた変更と改善により、以前のファームウェアよりもPCIe VDM上のMCTPが無効になります。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Changes and improvements that have been made in the firmware HPK4 which disable MCTP over PCIe VDM over the previous firmware.</p>","Lang":"cn"}],"Version":"HPK4"}],"SWKeys":[{"Name":"VR000480KXNXE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KXNZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VS001920KXNXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"b8cf44de46d94ae9b0f6781016022a00"}]},{"ProductId":"cf3d0ea161014094b2ae4ebd26456a93","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains optimization to increase the time for Recovery operation and few checks for maintenance.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"6774281","DateModified":"2025-05-14T05:58:49","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/CP066530.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/HPG1_PM897.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066530.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066530.scexe"],"MD5Sum":"df348fa31670c908253826098d0b724d","Name":"firmware-hdd-9475583fb5-HPG1-5.1.x86_64.rpm","Release":"2025-05-14T10:46:04","Revision":"E","SHA1Sum":"e81790b2bc3e3a9620dd41c285789b4f7b768a54","SHA256Sum":"a0ebef9688d6c0dbd9f4adbf0ee445c4600ada8d826be676848638d11c18c8f3","Size":"6MB","TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040346.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:52:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8913f08ab2ed4d3292440bce70484eae"}]},{"ProductId":"15c5494e659e4865b78e60077bae7860","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXF"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features:&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"}],"Files":[{"Bytes":"5809928","DateModified":"2025-01-11T00:09:13","FileList":["85032G00_mp.bin","cp064855.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"f93e00eadbc113c690eecf1390dccbc4","Name":"cp064855.exe","Release":"2025-01-11T00:03:29","Revision":"F","SHA1Sum":"0fdeaaa5836e7ed537e960752999c95daf2bc4ff","SHA256Sum":"ac1cb90b083d4a9bdaa34062ac7f4194b9c8a2f072169024400cee668120e2b1","Size":"5MB","TargetGUIDs":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"TypeOfChange":"1","Version":"85032G00"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"},{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:17:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6fce20ea135b4db1a64e2164c723438e"}]},{"ProductId":"bba1d0334a5f4b5fbc1a282af5290868","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD3"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD3"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4654152","DateModified":"2025-01-11T11:19:13","FileList":["cp065084.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPESD3.rel","setup.dll"],"MD5Sum":"9c5c838bb11127f4a22702da33e809ac","Name":"cp065084.exe","Release":"2025-01-11T11:14:37","Revision":"B","SHA1Sum":"42042ccfdd75f87393a0d1f56a82597fec1bab68","SHA256Sum":"77b3b14a88aa8f958af7dbe8abccd5e940c090aa1c31264e75bd97713d0839cb","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:27:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"62dc5e8dc509469e808d518e7d1d8f9d"}]},{"ProductId":"1f91b74faf084255b33a9e102dcf221d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11565992","DateModified":"2025-05-14T21:51:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/CP067217.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/U45_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067217.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067217.scexe"],"MD5Sum":"b0f8f477d8caec3c7edaff5e0fa26f4d","Name":"firmware-system-u45-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T02:43:04","Revision":"B","SHA1Sum":"a34233444c33ba9702a10fbc714e1afa9faf6ee0","SHA256Sum":"457ea83a233ae026830524849442b7b57b5c47e2136cab6881eb6cf17c61572e","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>RPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T02:25:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1b95820a5abc4a94bc5151bdc792f5d7"}]},{"ProductId":"9681dd7da3ad4cfa8b9f5d2fa3efb5ac","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1076880","DateModified":"2025-04-01T03:44:19","FileList":["cp065274.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"e61cb019d2f83e1369021b99fe6bdd40","Name":"cp065274.exe","Release":"2025-04-01T03:30:31","Revision":"B","SHA1Sum":"7ff6e7119714846f7059813d7608872ee3b69c15","SHA256Sum":"07bb95a630aabc4bd1d4e9f22f73a41c8f8ce857fd8e9dcb598d7143f9b6d705","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i350 Driver for Windows Server 2025"},{"Lang":"ja","Value":"Intel i350 Driver for Windows Server 2025"},{"Lang":"cn","Value":"Intel i350 Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:35:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"14.1.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"14.1.5.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5f13811951474126a5c096ee9ec6acff"}]},{"ProductId":"39b3bcd8f8b243ad9879002d6ba846cc","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"17287799","DateModified":"2024-12-11T07:57:01","FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.21-150500.53-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"MD5Sum":"eb78e33b0c99880a456a306b1213eb4a","Name":"qlgc-fastlinq-kmp-default-8.74.6.0_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2024-12-11T07:32:17","Revision":"","SHA1Sum":"dbb763ce12d5b0ce40148eee6ab19776afd5e0e0","SHA256Sum":"147d9e5430a8e84481ed1315bc91ca674f0ccec4e18f1f4aea510008e9f1a579","Size":"16MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.74.6.0-1"},{"Bytes":"18139189","DateModified":"2024-12-11T08:02:27","FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"MD5Sum":"3f9e580740ed7a5132125dd233c7c051","Name":"qlgc-fastlinq-kmp-default-8.74.6.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2024-12-11T07:32:17","Revision":"","SHA1Sum":"16cae559de529928035f8e608d3a21307e7693ab","SHA256Sum":"0583934d5813b7365c0ebc51413877168cc31fedf07c7b15490392a8d674185c","Size":"17MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.74.6.0-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15用HPE QLogic FastLinQ 10/25/50 GbEドライバー"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"cn"}],"Version":"8.74.4.0-8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.74.6.0-1"}],"SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e31cd0e58aa644a495b75c3dacb3d5c6"}]},{"ProductId":"85a59acb7d634eb691745a6c9906ad03","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."},{"Lang":"ja","Value":"Smart Storage Administrator CLIは、SmartアレイコントローラーおよびSmartRAIDコントローラー用のコマンドラインベースのディスク構成プログラムです。"},{"Lang":"cn","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"12768308","DateModified":"2025-03-12T04:17:38","FileList":["/cp064903.xml","/MIS_bootbank_ssacli2_6.50.8.0-1OEM.900.0.24580437.vib","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/index.xml","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/vendor-index.xml","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/metadata.zip","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.50.8.0-1OEM.900.0.24580437.vib","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/metadata.zip/vmware.xml","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/metadata.zip/vibs/ssacli2--4828373022870144517.xml","/ssacli2-component_6.50.8.0-1OEM.900.0_24630237.zip/metadata.zip/bulletins/ssacli2-component_6.50.8.0-1OEM.900.0.xml"],"MD5Sum":"59f4bda86ffffd2ac5363c032cd2038c","Name":"cp064903.zip","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"f24d817b6070dd7197c1b95c1438d1c8c08e575c","SHA256Sum":"85c46b17a003ce011cc776ee9784990e8032d1108349be6a4f67d8b98bbfe96b","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2025.03.01","VibList":[{"Name":"ssacli2","Version":"6.50.8.0-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI Smartコンポーネントfor ESXi 9.0 for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"7100"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:36:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial Release.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>最初のリリースです。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial Release.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial Release.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>最初のリリースです。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial Release.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"}],"SWKeys":[{"Name":"ssacli2-component:6.50.8.0-1OEM.900.0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.50.8.0-1OEM.900.0.24580437","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fe0a1d7408354dc58ff1d13feaf02324"}]},{"ProductId":"b27e4086749b43a09022b1ccf9b6e0c0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe) to (ixgbe). Now we revert this change from (ixgbe) to (<strong>hp</strong>-ixgbe).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbe and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbe and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbe）から（ixgbe）に変更されました。この変更を（ixgbe）から（<strong>hp</strong>-ixgbe）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-ixgbeとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbeによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbe) to (ixgbe). Now we revert this change from (ixgbe) to (<strong>hp</strong>-ixgbe).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbe and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbe-5.19.6-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbe and then install the updated RPM.</p>"}],"Files":[{"Bytes":"359954","DateModified":"2025-04-01T07:54:09","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/371bf675e035e93d83e688181532abae872dcf","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"MD5Sum":"1ce49d60149546ef4313e3e47a0dcf45","Name":"kmod-hp-ixgbe-5.22.25-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T07:13:07","Revision":"","SHA1Sum":"3a8f70502e1d301081fb57dc2de8b3a7ba8bb643","SHA256Sum":"ebd7d2ab0e29ada2934734f6ac4fc889ac620dca0e2e662fce0b1e97359c20c9","Size":"351KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"5.22.25-1"},{"Bytes":"360176","DateModified":"2025-04-01T07:49:04","FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/98","./usr/lib/.build-id/98/05fb7f22471e364c0ee289a0cda951bbce8c73","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"MD5Sum":"5180da7d41b6852963ed585182cd02b2","Name":"kmod-hp-ixgbe-5.22.25-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T07:13:07","Revision":"","SHA1Sum":"e47d7204c5ac52826a3fcf9a213829b2316abcdf","SHA256Sum":"fae77409905facf3a7f616ca34977631bffaaba6de857969db49b8c09abb1301","Size":"351KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"5.22.25-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:02:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、カーネルのコンパイルの問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"5.21.5-1"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"5.22.25-1"}],"SWKeys":[{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"150fe52eb75d494da70a129e75f16e63"}]},{"ProductId":"5d8c4ca5e9ce4b8ab296e754f4544502","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD4"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4507384","DateModified":"2025-01-11T11:30:16","FileList":["cp065085.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPNSD4.rel","setup.dll"],"MD5Sum":"0762874c8a6c5a0a1ef146ab7b446cd0","Name":"cp065085.exe","Release":"2025-01-11T11:26:31","Revision":"B","SHA1Sum":"b25ce05fe93952c65d40ec447f6572803c302b07","SHA256Sum":"74a2c889290d8c8fd3adee3b13b87c5d7462b0e4fa8dae72f50124610cbe9eb3","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:28:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"19f19c66bfec4a3c8005e3d4506f8f14"}]},{"ProductId":"cf36f8009ed4464f93a208bf9c35b47b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"795982","DateModified":"2025-05-24T09:06:32","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"MD5Sum":"9255b87f5d53bbe7afc1be608dd10a15","Name":"elx-lpfc-kmp-default-14.4.473.24_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"ef5e9ebfefe293cd5f3bebb5dc2f5c7140fa81e3","SHA256Sum":"71f362c978d8e42591953a2fbe0c8dfcf3900d3ae1d83adf5dec5d2dd0d65117","Size":"777KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.473.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1. システム管理者 (root) としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br /><br />                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p><p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p><p>同じドライバーバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります</p><p>例：rpm –Uvh elx-lpfc-kmp-default-<version>.<OSupdate>.x86_64.rpm --reinstall</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.589.5_k5.14.21_150400.22-1.sles15sp4.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15 Service Pack 6ファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプター"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"}],"SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bbde0afedb0c4c1095cfce2f5b2b2527"}]},{"ProductId":"f4d3c3f0b12d4c1da09c3d11188e06cf","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p><p><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Implements FW-based VPD.</li><li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li><li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li></ul>"}],"Files":[{"Bytes":"7703517","DateModified":"2025-05-14T05:36:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/CP066570.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066570.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066570.scexe"],"MD5Sum":"8b725b5a1fbc2653f32f133c0ec1b892","Name":"firmware-hdd-805abb7e9c-85032G00-11.1.x86_64.rpm","Release":"2025-05-14T10:25:00","Revision":"K","SHA1Sum":"d38499e515c75794497add70eeda738cff64dbfc","SHA256Sum":"b5a4c5b29868dff844409e58c492499c1ddddd5e193dd1ddf071c6130a648ded","Size":"7MB","TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"Installation":{"Command":"CP042967.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"},{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:52:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"7feb2261c8eb4f31b117addcbfaf153b"}]},{"ProductId":"8bfd6c84c6a049339ae439f038925df1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17439232","DateModified":"2025-05-21T02:42:16","FileList":["cp067160.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U60_2.40_05_16_2025.signed.flash"],"MD5Sum":"d2b59292355f909398e8c0b90d57c233","Name":"cp067160.exe","Release":"2025-05-21T02:39:11","Revision":"","SHA1Sum":"37acbf8998deee6d66c376e99207bd2c3ef24aee","SHA256Sum":"c3f3fbbfd6c7e7a6d5501247f3c26cd4929839f82ed0507051906f0263f53b4b","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL20 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:28:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"ce40944e526a4e0a9170988b76af587a"}]},{"ProductId":"953566d3c1ab4efe9b762b361100a259","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b5a595755","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b5a595842","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b5a595843","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5a595754","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b5a595756","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b5a595841","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[],"Files":[{"Bytes":"1596760","DateModified":"2023-12-03T22:38:13","FileList":["payload.json","Solidigm_P5x20_4IAAHPK5.HPb","Solidigm_P5x20_4IAAHPK5.xml"],"MD5Sum":"a9abe39a27df6cdc0a4b03bf19445629","Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","Release":"2023-12-03T22:34:54","Revision":"","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO001600KZYWU","TargetGUID":"4d2340a5-304f-3130-3630-304b5a595755","Type":"nvme"},{"Id":"MO003200KZYXB","TargetGUID":"4d2340a5-304f-3330-3230-304b5a595842","Type":"nvme"},{"Id":"MO006400KZYXC","TargetGUID":"4d2340a5-304f-3630-3430-304b5a595843","Type":"nvme"},{"Id":"VO001920KZYWT","TargetGUID":"562340a5-304f-3130-3932-304b5a595754","Type":"nvme"},{"Id":"VO003840KZYWV","TargetGUID":"562340a5-304f-3330-3834-304b5a595756","Type":"nvme"},{"Id":"VO007680KZYXA","TargetGUID":"562340a5-304f-3730-3638-304b5a595841","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-01-03T17:01:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware provides bug fixes for the P5620/P5520.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"MO001600KZYWU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KZYXB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KZYXC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KZYWT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KZYWV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KZYXA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"4412e3e7c98649b3bd32cc53ac661f12"}]},{"ProductId":"624ecf606d7d4d2c94cae219a5491b9e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"850672","DateModified":"2024-11-20T08:10:16","FileList":["cp064585.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"MD5Sum":"7484540ef8ec4fe8ef5a6c9aa979c25f","Name":"cp064585.exe","Release":"2024-11-20T07:56:06","Revision":"","SHA1Sum":"9239c100c3472afcca20c6c94b6716bba2586779","SHA256Sum":"958c6a1f46ea5c21dd873c2f3bdc22ddc281312274ac82fa4507c804f6f8bdf6","Size":"830KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.2.10.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel vxs Driver for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-20T01:39:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.2.10.0"}],"SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d1dddee027b34405847b0900c621181d"}]},{"ProductId":"308794285e444711a0eb3833d54eb10e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000600JWCPFおよびEH000900JWCPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDD<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDC<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"4119264","DateModified":"2025-01-11T08:59:21","FileList":["cp064865.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTEDD.rel"],"MD5Sum":"3957950c286452a8372df2c76f1336fa","Name":"cp064865.exe","Release":"2025-01-11T08:54:53","Revision":"B","SHA1Sum":"ba9b4f8f1cdfc5c11470974753b1d704bfe9580f","SHA256Sum":"d54986a92022f8d631ccfdcd88af6518c3d596a36121ad377bef168326094544","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000600JWCPF","TargetGUID":"452340a5-3048-3030-3630-304a57435046","Type":"sas"},{"Id":"EH000900JWCPH","TargetGUID":"452340a5-3048-3030-3930-304a57435048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T10:17:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixing Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDD"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDD"}],"SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"08598475db86417ebc7f27be3c58cddb"}]},{"ProductId":"dd0182917bf14543bf436162a2a05331","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000JXMTH and MB020000JXMTP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000JXMTHおよびMB020000JXMTP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000JXMTH and MB020000JXMTP&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6215789","DateModified":"2025-05-14T08:31:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/CP066559.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066559.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066559.scexe"],"MD5Sum":"051818c3953fbadf7bd4695be4018cb2","Name":"firmware-hdd-020fc874ad-HPD3-2.1.x86_64.rpm","Release":"2025-05-14T13:19:04","Revision":"B","SHA1Sum":"f9e2d7f72952006160a8d5c31bb21da11aca1384","SHA256Sum":"1323ab1145ed6954fc51e0cf8b245994d0da4534a5210f137aebf4241ea0e37b","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB018000JXMTHおよびMB020000JXMTPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000JXMTP","TargetGUID":"4d2340a5-3042-3032-3030-304a584d5450","Type":"sas"},{"Id":"MB018000JXMTH","TargetGUID":"4d2340a5-3042-3831-3030-304a584d5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:54:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"271d84d3d5984385bdf27d26a6cf2848"}]},{"ProductId":"93312d51d8f7459ba48a2a8cbf6722a2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."},{"Lang":"ja","Value":"Smart Storage Administrator CLIは、SmartアレイコントローラーおよびSmartRAIDコントローラー用のコマンドラインベースのディスク構成プログラムです。"},{"Lang":"cn","Value":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"16392999","DateModified":"2024-11-18T11:53:43","FileList":["/cp062924.xml","/MIS_bootbank_ssacli2_6.45.8.0-8.0.0.20613240.oem.vib","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/index.xml","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/vendor-index.xml","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/metadata.zip","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.45.8.0-8.0.0.20613240.oem.vib","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/metadata.zip/vmware.xml","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/metadata.zip/vibs/ssacli2--1651489824927522070.xml","/ssacli2-component_6.45.8.0-8.0.0_24383802.zip/metadata.zip/bulletins/ssacli2-component_6.45.8.0-8.0.0.xml"],"MD5Sum":"fd27b0bd58605e95d9e89cf4b5e1a5cb","Name":"cp062924.zip","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"9e40e35d68374fd013a44018edc3543e631d3b80","SHA256Sum":"6d6b0c9cfdae4ca7d0225796aada2805db1c6c8e07398fd8d053127107a96ce9","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2025.02.01","VibList":[{"Name":"ssacli2","Version":"6.45.8.0-8.0.0.20613240.oem"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li><li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li></ol><p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) CLI Smartコンポーネントfor ESXi 8.0 for Gen10/Gen10 Plus/Gen11コントローラー"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"7100"},"SupportedDevices":[{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:34:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Write Cache Status field to the info page for physical drives when &quot;pd all show detail&quot; is used.</li></ul>","Fixes":"<ul><li>Corrected wrong wording of Parity Initialization messages.</li><li>Fixed vulnerability CVE-2023-45853.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>「pd all show detail」が使用される場合、物理ドライブの情報ページに書き込みキャッシュステータスフィールドが追加されました。</li></ul>","Fixes":"<ul><li>パリティ初期化メッセージの誤った表現を修正しました。</li><li>脆弱性CVE-2023-45853を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added Write Cache Status field to the info page for physical drives when &quot;pd all show detail&quot; is used.</li></ul>","Fixes":"<ul><li>Corrected wrong wording of Parity Initialization messages.</li><li>Fixed vulnerability CVE-2023-45853.</li></ul>","Lang":"cn"}],"Version":"2025.02.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Write Cache Status field to the info page for physical drives when &quot;pd all show detail&quot; is used.</li></ul>","Fixes":"<ul><li>Corrected wrong wording of Parity Initialization messages.</li><li>Fixed vulnerability CVE-2023-45853.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>「pd all show detail」が使用される場合、物理ドライブの情報ページに書き込みキャッシュステータスフィールドが追加されました。</li></ul>","Fixes":"<ul><li>パリティ初期化メッセージの誤った表現を修正しました。</li><li>脆弱性CVE-2023-45853を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added Write Cache Status field to the info page for physical drives when &quot;pd all show detail&quot; is used.</li></ul>","Fixes":"<ul><li>Corrected wrong wording of Parity Initialization messages.</li><li>Fixed vulnerability CVE-2023-45853.</li></ul>","Lang":"cn"}],"Version":"2025.02.01"}],"SWKeys":[{"Name":"ssacli2-component:6.45.8.0-8.0.0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.45.8.0-8.0.0.20613240.oem","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4504b100d29c416ab225d299c2a646cc"}]},{"ProductId":"96fe9c5a9b9741d5bcf4ae73623359e0","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_4506-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"},{"Lang":"ja","Value":"HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ：HPE部品番号P31246-B21およびP31246-H21"},{"Lang":"cn","Value":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported 1/10GbE Cables:</strong></p><ul><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; &nbsp;HPE BLc 10Gb SR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BLc 10Gb LR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adapter Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487649-B21 &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 0.5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487652-B21 &nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487658-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 7m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP785A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP818A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP819A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9150A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC SR Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9151A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;J9152A&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LRM Transceiver&nbsp;</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9281B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ to SFP+ 1m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9283B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ SFP+ 3m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;JD096B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD097C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 3m DAD Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD096C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD095C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 0.65m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ839A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 50m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ838A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 30m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ836A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ834A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ833A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 0.5m Multi-mode OM3 LC/LC FC Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;487652-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;AP820A&nbsp;&nbsp; &nbsp; &nbsp;&nbsp; &nbsp;HPE 5m B-series Active Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D93A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1.5m Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D94A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 2m B-series Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;JG329A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE&nbsp;&nbsp; &nbsp;JG330A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li></ul><p><strong>Validated and Supported 25 GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21 &nbsp;&nbsp; &nbsp;HPE QSFP 28 to SFP28 Adaptor</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844471-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844474-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844477-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844480-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 15m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ SR4 100m (40G)</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG326A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 1m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG327A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 3m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG328A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 5m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG331A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ 40Gb Bi-Directional XCVR&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720205-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 7m AOC Cable &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720208-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 10m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721070-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721073-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt&nbsp;&nbsp;</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 7m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B21&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 1m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B22&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 2m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B23 &nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B23&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 10m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B26&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 15m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B27&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 20m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B28&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 30m</li><li>40GB/S&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720190-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ LC LR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp; &nbsp;HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Q7F11A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 40GbE QSFP28 SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670759-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP passive copper cable, 1.5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B21&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 3m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B22&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 7m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B24&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 10m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B25&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 12m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B26&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 15m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B27&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 20m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 30m</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B21&nbsp;&nbsp; &nbsp;HPE 3 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B22&nbsp;&nbsp; &nbsp;HPE 5 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B23&nbsp;&nbsp; &nbsp;HPE 7 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B24&nbsp;&nbsp; &nbsp;HPE 10 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B25&nbsp;&nbsp; &nbsp;HPE 12 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B26&nbsp;&nbsp; &nbsp;HPE 15 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B27&nbsp;&nbsp; &nbsp;HPE 20 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B28&nbsp;&nbsp; &nbsp;HPE 30 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>40GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JL251A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845966-B21 &nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845418-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;JL273A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 5M DAC Cable - 5m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL271A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 1M DAC Cable - 1m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL272A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 3M DAC Cable - 3m</li><li>100GbE&nbsp;&nbsp; &nbsp;845404-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 1m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845402-B21&nbsp; &nbsp; HPE 100Gb QSFP28 to QSFP28 0.5m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;882251-B21&nbsp;&nbsp; &nbsp;HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>Note:&nbsp;</strong>Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされる1/10GbEケーブル：</strong></p><ul><li>1GbE/10GbE 455883-B21 HPE BLc 10Gb SR SFP+オプション</li><li>1GbE/10GbE 455886-B21 HPE BLc 10Gb LR SFP+オプション</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE 537963-B21 HPE BLc SFP+ 5m 10GbE銅線ケーブル</li><li>1GbE/10GbE    655874-B21        HPE QSFP/SFP+アダプターキット</li><li>10GbE        813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE        838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li><li>1GbE/10GbE    487649-B21         HPE BLc SFP+ 0.5m 10GbE銅ケーブル</li><li>1GbE/10GbE 487652-B21 HPE BLc SFP+ 1m 10GbE銅線ケーブル</li><li>1GbE/10GbE 487658-B21 HPE BLc SFP+ 7m 10GbE銅線ケーブル</li><li>1GbE/10GbE AP784A         HPE 3m CシリーズSFP+パッシブ銅線ケーブル</li><li>1GbE/10GbE AP785A        HPE 5m CシリーズSFP+パッシブ銅線ケーブル</li><li>1GbE/10GbE AP818A        HPE 1m BシリーズSFP+アクティブ銅線ケーブル</li><li>1GbE/10GbE AP819A        HPE 3m BシリーズSFP+アクティブ銅線ケーブル</li><li>1GbE/10GbE J9150A        HPE X132 10G SFP+ LC SRトランシーバー</li><li>1GbE/10GbE   J9151A        HPE X132 10G SFP+ LC LRトランシーバー</li><li>10GbE        J9152A         HPE X132 10G SFP+ LC LRMトランシーバー </li><li>1GbE/10GbE   J9281B        HPE X242 10G SFP+ to SFP+ 1m直接接続銅線ケーブル</li><li>1GbE/10GbE   J9283B        HPE X242 10G SFP+ SFP+ 3m DACケーブル</li><li>1GbE/10GbE   JD096B        HPE X240 10G SFP+ SFP+ 1.2m DACケーブル</li><li>10GbE        JD097C        HPE X240 10G SFP+ SFP+ 3m DADケーブル</li><li>10GbE        JD096C        HPE X240 10G SFP+ SFP+ 1.2m DACケーブル</li><li>10GbE        JD095C        HPE X240 10G SFP+ SFP+ 0.65m DACケーブル</li><li>1GbE/10GbE AJ839A        HPE 50mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ838A        HPE 30mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ836A        HPE 5mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ834A        HPE 1mマルチモードOM3 LC/LC FCケーブル</li><li>1GbE/10GbE AJ833A        HPE 0.5mマルチモードOM3 LC/LC FCケーブル</li><li>10GBE        487652-B21    HPE BLc SFP+ 1m 10GbE銅ケーブル</li><li>10GBE        AP820A         HPE 5m BシリーズSFP+アクティブ銅線ケーブル</li><li>10GBE    E3D93A            HPE 1.5m SFP+銅線ケーブル</li><li>10GBE    E3D94A            HPE 2m BシリーズSFP+銅線ケーブル</li><li>10GBE    JG329A            HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE    JG330A            HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE AP784A        HPE 3m CシリーズSFP+パッシブ銅線ケーブル</li></ul><p><strong>検証済みおよびサポートされる25 GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター</li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE    844471-B21    HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE    844474-B21    HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE    844477-B21    HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE    844480-B21    HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー</li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE        720211-B21    HPE BLc 40G QSFP+ QSFP+ 15m AOCケーブル  </li><li>40GbE        721076-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE        720187-B21    HPE QSFP+ SR4 100m (40G)</li><li>40GbE        JG325B        HPE X140 40G QSFP+ MPO SR4トランシーバー</li><li>40GbE        JG325A        HPE X140 40G QSFP+ MPO SR4トランシーバー</li><li>40GbE        JG326A        HPE X240 40G QSFP+ QSFP+ 1m DACケーブル</li><li>40GbE        JG327A        HPE X240 40G QSFP+ QSFP+ 3m DACケーブル</li><li>40GbE        JG328A        HPE X240 40G QSFP+ QSFP+ 5m DACケーブル</li><li>40GbE        JG331A        HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE        841716-B21    HPE QSFP+ 40Gb双方向XCVR  </li><li>40GbE        720205-B21    HPE BLc 40G QSFP+ QSFP+ 7m AOCケーブル  </li><li>40GbE        720208-B21    HPE BLc 40G QSFP+ QSFP+ 10m AOCケーブル  </li><li>40GbE        721070-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt  </li><li>40GbE        721073-B21    HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt  </li><li>QDR/FDR10    498385-B25    QDR/FDR10 InfiniBand QSFP銅ケーブル、7m</li><li>QDR/FDR10    498385-B24    QDR/FDR10 InfiniBand QSFP銅ケーブル、5m</li><li>QDR/FDR10    498385-B21    QDR/FDR10 InfiniBand QSFP銅ケーブル、1m</li><li>QDR/FDR10    498385-B22    QDR/FDR10 InfiniBand QSFP銅ケーブル、2m</li><li>QDR/FDR10    498385-B23     QDR/FDR10 InfiniBand QSFP銅ケーブル、3m</li><li>QDR/FDR10    498386-B23    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、3m</li><li>QDR/FDR10    498386-B24    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、5m</li><li>QDR/FDR10    498386-B25    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、10m</li><li>QDR/FDR10    498386-B26    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、15m</li><li>QDR/FDR10    498386-B27    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、20m</li><li>QDR/FDR10    498386-B28    QDR/FDR10 InfiniBand QSFPアクティブファイバーケーブル、30m</li><li>40GB/S        720190-B21    HPE BladeSystem c-Class 40Gb QSFP+ LC LR4トランシーバー</li><li>40GbE        670760-B28 HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand光ケーブル</li><li>40GbE        Q7F11A        HPE Mシリーズ40GbE QSFP28 SR4 100mトランシーバー</li><li>40GbE        670759-B23    FDR InfiniBand QSFPパッシブ銅線ケーブル、1.5m</li><li>40GbE        670760-B21    FDR InfiniBand QSFPアクティブファイバーケーブル、3m</li><li>40GbE        670760-B22    FDR InfiniBand QSFPアクティブファイバーケーブル、5m</li><li>40GbE        670760-B23    FDR InfiniBand QSFPアクティブファイバーケーブル、7m</li><li>40GbE        670760-B24    FDR InfiniBand QSFPアクティブファイバーケーブル、10m</li><li>40GbE        670760-B25    FDR InfiniBand QSFPアクティブファイバーケーブル、12m</li><li>40GbE        670760-B26    FDR InfiniBand QSFPアクティブファイバーケーブル、15m</li><li>40GbE        670760-B27    FDR InfiniBand QSFPアクティブファイバーケーブル、20m</li><li>40GbE        670760-B28     FDR InfiniBand QSFPアクティブファイバーケーブル、30m</li><li>FDR        808722-B21 HPE 3 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B22 HPE 5 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B23 HPE 7 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B24 HPE 10 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B25 HPE 12 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B26 HPE 15 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B27 HPE 20 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>FDR        808722-B28 HPE 30 Meter InfiniBand FDR QSFP Vシリーズ光ケーブル</li><li>40GBE        JL251A         HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE        841716-B21   HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21        HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21        HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3mダイレクトアタッチ銅線ケーブル</li><li>100GbE    845972-B21        HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GbE    845414-B21        HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GbE 845966-B21  HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GbE    845418-B21        HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE    JL273A        HPE X240 100G QSFP28 5M DACケーブル - 5m</li><li>100GBE    JL271A         HPE X240 100G QSFP28 1M DACケーブル - 1m</li><li>100GBE    JL272A        HPE X240 100G QSFP28 3M DACケーブル - 3m</li><li>100GbE    845404-B21    HPE 100Gb QSFP28 to QSFP28 1mダイレクトアタッチ銅線ケーブル</li><li>100GBE    845402-B21    HPE 100Gb QSFP28 to QSFP28 0.5mダイレクトアタッチ銅線ケーブル</li><li>100GbE    882251-B21        HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>注記：</strong>このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported 1/10GbE Cables:</strong></p><ul><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; &nbsp;HPE BLc 10Gb SR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BLc 10Gb LR SFP+ Opt</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adapter Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487649-B21 &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 0.5m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487652-B21 &nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487658-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 7m 10GbE Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP785A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m C-series Passive Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP818A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP819A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m B-series Active Copper SFP+ Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9150A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC SR Transceiver</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9151A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;J9152A&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X132 10G SFP+ LC LRM Transceiver&nbsp;</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9281B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ to SFP+ 1m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;J9283B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X242 10G SFP+ SFP+ 3m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;JD096B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD097C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 3m DAD Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD096C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 1.2m DAC Cable</li><li>10GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JD095C&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 10G SFP+ SFP+ 0.65m DAC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ839A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 50m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ838A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 30m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ836A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 5m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ834A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1m Multi-mode OM3 LC/LC FC Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AJ833A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 0.5m Multi-mode OM3 LC/LC FC Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;487652-B21&nbsp;&nbsp; &nbsp;HPE BLc SFP+ 1m 10GbE Copper Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;AP820A&nbsp;&nbsp; &nbsp; &nbsp;&nbsp; &nbsp;HPE 5m B-series Active Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D93A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 1.5m Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;E3D94A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 2m B-series Copper SFP+ Cable</li><li>10GBE&nbsp;&nbsp; &nbsp;JG329A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 1m</li><li>10GBE&nbsp;&nbsp; &nbsp;JG330A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 3m</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;AP784A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 3m C-series Passive Copper SFP+ Cable</li></ul><p><strong>Validated and Supported 25 GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21 &nbsp;&nbsp; &nbsp;HPE QSFP 28 to SFP28 Adaptor</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844471-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 0.5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844474-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 1m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844477-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 3m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844480-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 5m DAC</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 15m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ SR4 100m (40G)</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325B&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG325A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ MPO SR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG326A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 1m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG327A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 3m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG328A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ QSFP+ 5m DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JG331A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 40G QSFP+ to 4x10G SFP+ 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE QSFP+ 40Gb Bi-Directional XCVR&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720205-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 7m AOC Cable &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720208-B21&nbsp;&nbsp; &nbsp;HPE BLc 40G QSFP+ QSFP+ 10m AOC Cable&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721070-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 7m Opt&nbsp;&nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;721073-B21&nbsp;&nbsp; &nbsp;HPE BLc QSFP+ to 4x10G SFP+ AOC 10m Opt&nbsp;&nbsp;</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 7m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B21&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 1m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B22&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 2m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498385-B23 &nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP copper cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B23&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 3m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B24&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 5m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B25&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 10m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B26&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 15m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B27&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 20m</li><li>QDR/FDR10&nbsp;&nbsp; &nbsp;498386-B28&nbsp;&nbsp; &nbsp;QDR/FDR10 InfiniBand QSFP active fiber cable, 30m</li><li>40GB/S&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;720190-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ LC LR4 Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp; &nbsp;HPE 30M FDR Quad Small Form Factor Pluggable InfiniBand Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Q7F11A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 40GbE QSFP28 SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670759-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP passive copper cable, 1.5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B21&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 3m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B22&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 5m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B23&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 7m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B24&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 10m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B25&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 12m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B26&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 15m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B27&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 20m</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;670760-B28&nbsp;&nbsp;&nbsp; &nbsp;FDR InfiniBand QSFP active fiber cable, 30m</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B21&nbsp;&nbsp; &nbsp;HPE 3 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B22&nbsp;&nbsp; &nbsp;HPE 5 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B23&nbsp;&nbsp; &nbsp;HPE 7 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B24&nbsp;&nbsp; &nbsp;HPE 10 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B25&nbsp;&nbsp; &nbsp;HPE 12 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B26&nbsp;&nbsp; &nbsp;HPE 15 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B27&nbsp;&nbsp; &nbsp;HPE 20 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>FDR&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;808722-B28&nbsp;&nbsp; &nbsp;HPE 30 Meter InfiniBand FDR QSFP V-series Optical Cable</li><li>40GBE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;JL251A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X140 40G QSFP+ LC BiDi 100m MM XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40GbE QSFP+ BiDi XCVR</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845966-B21 &nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 MPO SR4 100m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845418-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;JL273A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 5M DAC Cable - 5m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL271A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 1M DAC Cable - 1m</li><li>100GBE&nbsp;&nbsp; &nbsp;JL272A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X240 100G QSFP28 3M DAC Cable - 3m</li><li>100GbE&nbsp;&nbsp; &nbsp;845404-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 1m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;845402-B21&nbsp; &nbsp; HPE 100Gb QSFP28 to QSFP28 0.5m Direct Attach Copper Cable</li><li>100GBE&nbsp;&nbsp; &nbsp;882251-B21&nbsp;&nbsp; &nbsp;HPE SY 100GE/4x25GE/4x32GFC QSFP28 XCVR</li></ul><p><strong>Note:&nbsp;</strong>Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"5653649","DateModified":"2025-04-11T10:01:16","FileList":["16_35_4506-MCX515A-CCA_HPE_Ax.pldm.signed","16_35_4506-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"5f8a7433514f82a2bad97a73cf5a3e94","Name":"16_35_4506-MCX515A-CCA_HPE_Ax.pldm.fwpkg","Release":"2025-04-11T09:59:06","Revision":"","SHA1Sum":"f348dd9cccfd2d3242bc93a22ff34018948a74c1","SHA256Sum":"e44167949aee6e1d45959ccdcab4e6227b1e0781521f3586930b03c7046acfca","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715900346"],"TypeOfChange":"1","Version":"16.35.4506"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li style=\"margin-left: 80px;\"><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li style=\"margin-left: 80px;\"><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li style=\"margin-left: 80px;\"><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li style=\"margin-left: 80px;\"><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"},{"Lang":"ja","Value":"Mellanoxファームウェアパッケージ（FWPKG）for HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター：HPE部品番号P31246-B21およびP31246-H21"},{"Lang":"cn","Value":"Mellanox Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-11T09:36:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p>重要：セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのバージョンにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御の非PFドライバー構成 (SET_HCA_CAP.sw_r_roce_src_udp_portで設定) を無視したときに、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"16.35.4030"},{"ReleaseNotes":[{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p>Important : Security Hardening Enhancements - This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device firmware to this version to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"16.35.4506"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX515A-CCAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"49f2e767ba6342678d0b40e538791173"}]},{"ProductId":"ae7662457b594bb08733bceba6635c72","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssATFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB012000GWDFE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Mitigates the potential drive FW halt issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB012000GWDFE Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG3</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Mitigates the potential drive FW halt issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"6328566","DateModified":"2025-05-14T08:54:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/CP066537.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/WLEAsssATFG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066537.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066537.scexe"],"MD5Sum":"a42397d9acec1231fca28e3f9d71ac43","Name":"firmware-hdd-059b8654a6-HPG5-4.1.x86_64.rpm","Release":"2025-05-14T13:42:05","Revision":"D","SHA1Sum":"b8adbf1d534c521ed101feb89ca813ad6e6f532d","SHA256Sum":"2e9eeb6fb3489a37781ed9ee2c5c5b2af48930ac8998acb7d310d3f21567e2c2","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP040337.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWDFEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB012000GWDFE","TargetGUID":"4d2340a5-3042-3231-3030-304757444645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:28:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a2169e0248ae43efb588a8ff1cda63ac"}]},{"ProductId":"628a576c95694de3aab72daab877bb47","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20314881","DateModified":"2025-03-06T09:17:56","FileList":["/CP066010_BUILD_5.data","/CP066010.vmexe64","/CP066010.vmfile","/CP066010_VMw.zip","/CP066010.xml","/payload.json","/CP066010_VMw.zip/index.xml","/CP066010_VMw.zip/vendor-index.xml","/CP066010_VMw.zip/metadata.zip","/CP066010_VMw.zip/vib20/CP066010/HPE_bootbank_CP066010_HPD4.5-8.0.0.20613240.vib","/CP066010_VMw.zip/metadata.zip/vendor-index.xml","/CP066010_VMw.zip/metadata.zip/vmware.xml","/CP066010_VMw.zip/metadata.zip/vibs/CP066010-2648125330980124201.xml","/CP066010_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066010_HPD4.5-8.0.0.20613240.xml"],"MD5Sum":"95c8fbe95e5176d7ba9ea233ca7cc3ed","Name":"CP066010.zip","Release":"2025-03-06T09:17:12","Revision":"C","SHA1Sum":"0d428abe43450494d42563a02c9542cfea92ef9b","SHA256Sum":"6092c1c4056fa54750c4e6c7970781f8a1e65eacecc73985aa6cbf9b8dd8104d","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP066010","Version":"HPD4.5-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:08:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6025ac4d83194e2c9c1ebd2935c8df60"}]},{"ProductId":"3f857d7b01734aa494f8146516002d2e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-p_Gen10P_52.32.3-6118_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.32.3-6118"}]},"MinimumActiveVersion":"52.26.3.5487","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"HPE MR416i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"ja","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"},{"Lang":"cn","Value":"<p>One-Button Secure Erase (OBSE) and Online Firmware Activation (OFA) are not supported on HPE Gen10 servers so MR Gen10 plus controller doesn&#39;t support online firmware update on Gen10 server.<br />If there is a necessary to install FWPKG on HPE Gen10 servers, please expect that reboot is required after flash FWPKG.</p>"}],"Files":[{"Bytes":"7507615","DateModified":"2025-06-13T14:32:16","FileList":["HPE_MR416i-p_Gen10P_52.32.3-6118_A.HPb","HPE_MR416i-p_Gen10P_52.32.3-6118_A.xml","payload.json"],"MD5Sum":"4ca6fe9ae1f9979b726cff1cedb731d8","Name":"HPE_MR416i-p_Gen10P_52.32.3-6118_A.fwpkg","Release":"2025-06-13T14:29:10","Revision":"","SHA1Sum":"dadc7d52d803a50adba00e0710378808cb71953c","SHA256Sum":"f4dcc78f2439029881f233068ccc84fd9e185c28109ead3330db1f5f8dafbba7","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.32.3-6118"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p><p>Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller "},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE MR416i-p Gen10 Plusトライモードコントローラー "},{"Lang":"cn","Value":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and arenot applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>DMTF PLDM Redfishデバイス有効化機能強化: Redfish暗号化のサポートを追加(POST&PATCH）</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">注記: MRコントローラーはSEDのみをサポートします。したがって、Volume[EncryptionTypes]はPOST(作成)またはPATCH(アップデート)中に書き込みできません。それに応じて、次の注釈は入力されません。</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o 注記:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted]は、適格なボリュームに対してオプション「true」を指定してのみ発行できます。MRファームウェアではセキュアボリュームを非セキュアボリュームに変更できないため、オプション 'false' を指定した PATCH Volume[Encrypted] は失敗します。</li><li>POST (作成) 中に、RAIDType=Noneのボリュームを作成する場合、「暗号化」オプションは使用できません。これは、MRが1ステップで安全なJBODを作成することをサポートしていないためです。JBODを作成した後、PATCH Volume [Encrypted = true] を発行して安全なJBODを作成できます。</li><li>ユーザーがEKMへの変更を要求するたびに、UEFIドライバー経由でキーを取得するために再起動が必須になります。</li></ul><ul><li>MR408i-pのサポートを追加</li><li>UBM10バックプレーンのサポートを追加しました</li><li>FWアップデート中に中断が発生した場合、UBMコントローラーがブートローダ状態にあるときに、UBM バックプレーンFWバージョン表示とFWアップデートをサポートします。</li><li>マップ解除可能な論理ドライブ用の NVMe SSDをサポートします。SATA SSDは、マップ解除可能な論理ドライブではサポートされないことに注意してください。</li><li>NANDフラッシュリフレッシュの改善</li></ul><p style=\"margin-left:80px\">o 指定された日数後に「System reset required」というイベントを投稿するアルゴリズムが削除されました。更新は同じ指定された時間後に行われ、新しいイベントが以下のように入力されます。</p><ul><li style=\"margin-left: 80px;\">NANDフラッシュのリフレッシュを開始する前に: 「NAND refresh in progress:changing WB Logical Drives to WT」</li><li style=\"margin-left: 80px;\">NAND フラッシュのリフレッシュが完了したら、「NAND refresh complete:changing WT virtual disks to WB」</li><li style=\"margin-left: 80px;\">上記の動作はMR400コントローラーにのみ適用され、MR200コントローラーには適用されません。</li><li>RAID1整合性チェックイベント文字列の変更</li></ul><p style=\"margin-left:80px\">o イベント文字列が「Consistency Check found inconsistent parity on LD <Ld Id> at strip <Strip Number>」から「Consistency Check found inconsistency on LD <Ld Id> at strip <Strip Number>」に変更されました。</p><ul><li>シャットダウン時に構成されたドライブのスピンダウンを制御するための新しいコントローラープロパティ「Spin Down Drives At Shutdown」をサポートします。</li><li>SCSI NVMe変換レイヤー仕様バージョン1.14のサポート</li></ul>","Fixes":"<ul><li>修正 a00143232en_us: HPE MR Gen11 コントローラー - AMD EPYC 9xx5 2P構成のHPE ProLiant DL365/DL385 Gen11 サーバーでコンポーネント整合性ステータスがサポートされていないと表示される</li><li>修正 a00144054en_us: HPE MR Gen10 PlusおよびGen11ストレージコントローラー - システムが VMware ESXiオペレーティング システムを起動すると、SAS/SATA/NVMe ドライブファームウェアのアップデートが成功しない場合があります</li><li>修正 a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - 大量のI/OがアクティブなときにHPE MRSAに予期しない情報が表示される</li><li>CM7 FIPSドライブがSED対応ドライブとして識別されない問題を修正しました。CM7 FIPSドライブモデル番号: VO001920YXUHU、VO003840YXUHV、VO007680YXUJA、MO001600YXUJB、MO003200YXUJC、MO006400YXUJD、VV007680LYJKF、VV015360LYXMT、MV003200LYJKH、MV006400LYJKK。</li><li>無効なセキュリティキーを使用して外部ドライブをインポートすると、5回試行してもコントローラーが無限ループに陥る問題を修正しました。</li><li>PCI BARアップデートの進行中に MCTPトラフィックがあるとコントローラーがアサートする可能性がある問題を修正しました。</li><li>Redfish Drive.CapableSpeedGbsがSAS4ドライブに対して22.5ではなく22と表示される問題を修正しました。</li><li>ReuseTargetIdオプションを使用して同じコマンドで複数の論理ドライブを作成すると、作成される論理ドライブの数が予想よりも少なくなる問題を修正しました。</li><li>複数の論理ドライブ構成で固定キャッシュが生成されないことがある断続的な問題を修正</li><li>ホストのタスク管理によりオフライン ドライブ ファームウェアのダウンロードがタイムアウトしたにもかかわらず、ダウンロード完了イベントが生成されるというまれな問題を修正しました。</li><li>サーバーの起動前にキャッシュオフロードが発生すると、RAID5/50/6/60論理ドライブのパフォーマンスが低下する可能性がある問題を修正しました。</li><li>NVMeドライブでパトロール読み取りを実行しているときにコントローラーに障害が発生し、OCR (オンラインコントローラーリセット) で回復する可能性がある問題を修正しました。</li><li>NVMe JBODドライブの最大書き込み同一長または最大アンマップブロック記述子数が上書きされ、SCSI UNMAPまたはWRITE SAMEコマンドが失敗する問題を修正しました。</li><li>ホストが実行時に PCIe BARを構成すると、PCIeメモリ読み取りのUR(サポートされていない要求) が発生する可能性があるというまれな問題を修正しました。</li><li>0より大きく8より小さいパラメーターリストの長さを使用するSCSI UNMAPコマンドが、SCSIセンス キーの不正な要求とパラメーターリスト内の無効なフィールドの追加センスデータで失敗する問題を修正しました。</li><li>PCI bar初期化がブートメッセージ処理を待機してタイムアウトしたためにコントローラーがアサートされる可能性があるというまれな問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>DMTF PLDM Redfish Device Enablement enhancements: Add support for Redfish Encryption (POST &amp; PATCH)</li></ul><p style=\"margin-left:80px\">o POST Storage.SetEncryptionKey</p><p style=\"margin-left:80px\">o PATCH Storage[EncryptionMode]</p><p style=\"margin-left:80px\">o PATCH/POST Volume[Encrypted]</p><ul><li style=\"margin-left: 80px;\">Note: MR controller support SED only. Therefore, Volume[EncryptionTypes] is not writeable during POST (Create) or PATCH (Update). Correspondingly the following Annotations are not populated:</li></ul><p style=\"margin-left:120px\">a. EncryptionTypes@Redfish.AllowableValues (Volume Schema)</p><p style=\"margin-left:120px\">b. @Redfish.WriteableProperties[EncryptionTypes] (Volume Schema)</p><p style=\"margin-left:120px\">c. EncryptionTypes@Redfish.OptionalOnCreate (Volume Capabilities)</p><p style=\"margin-left:120px\">d. EncryptionTypes@Redfish.AllowableValues (Volume Capabilities)</p><p style=\"margin-left:120px\">e. EncryptionTypes@Redfish.UpdatableAfterCreate (Volume Capabilities)</p><p style=\"margin-left:80px\">o POST Volume.ForceEnable</p><p style=\"margin-left:80px\">o POST Drive.RevertToOriginalFactoryState</p><p style=\"margin-left:80px\">o Note:</p><ul style=\"margin-left:80px\"><li>PATCH Volume[Encrypted] can be issued only with option &lsquo;true&rsquo; on eligible volumes. PATCH Volume[Encrypted] with option &lsquo;false&rsquo; will befailed because a secure volume cannot be changed to an unsecurevolume in MR firmware.</li><li>During POST (Create) &lsquo;Encrypted&rsquo; option is not allowed for creating a volume with RAIDType=None. This is because MR does not support creating a secure JBOD in one step. After creating the JBOD, PATCH Volume [Encrypted = true] can be issued to create a secure JBOD.</li><li>Whenever user requests to change to EKM, a reboot is a must to obtain the key via UEFI driver.</li></ul><ul><li>Add MR408i-p support</li><li>Added support for UBM10 backplanes</li><li>Support UBM backplane FW version display and FW update when UBM controller is in bootloader state if there is an interruption during FW update</li><li>Support NVMe SSD for Unmap capable Logical Drive. Please note that SATA SSD is not supported for Unmap capable Logical Drive.</li><li>NAND flash refresh improvements</li></ul><p style=\"margin-left:80px\">o The algorithm that posts the event &quot;System reset required&quot; after a specified&nbsp; number of days has been removed. The refresh happens after the same specified time and the new events are populated as below:</p><ul><li style=\"margin-left: 80px;\">Before starting the Nand flash refresh: &ldquo;NAND refresh in progress:changing WB Logical Drives to WT&rdquo;</li><li style=\"margin-left: 80px;\">After the completion of Nand flash refresh: &ldquo;NAND refresh complete:changing WT virtual disks to WB&rdquo;</li><li style=\"margin-left: 80px;\">The above behaviors are applicable only to MR400 controllers and arenot applicable to MR200 controllers</li><li>RAID1 Consistency Check Event String Change</li></ul><p style=\"margin-left:80px\">o The Event String has been changed from &quot;Consistency Check found inconsistent parity on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot; to &quot;Consistency Check found inconsistency on LD &lt;Ld Id&gt; at strip &lt;Strip Number&gt;&quot;.</p><ul><li>Support a new controller property, &quot;Spin Down Drives At Shutdown&quot;, to control spindown of configured drives during shutdown</li><li>Support for SCSI NVMe Translation Layer Specification version 1.14</li></ul>","Fixes":"<ul><li>Fix a00143232en_us: HPE MR Gen11 Controllers - The Component Integrity Status Is Shown As Not Supported in HPE ProLiant DL365/DL385 Gen11 Servers With AMD EPYC 9xx5 2P Configurations</li><li>Fix a00144054en_us: HPE MR Gen10 Plus and Gen11 Storage Controllers - Updating the SAS/SATA/NVMe Drive Firmware May Not Succeed When the System Boots to the VMware ESXi Operating System</li><li>Fix a00142857en_us: HPE MegaRAID Storage Administrator (MRSA) - Unexpected Information Displays in the HPE MRSA When Heavy I/Os Are Active</li><li>Fix an issue that CM7 FIPS drives are not identified as SED capable drives. CM7 FIPSdrive Model Number: VO001920YXUHU,VO003840YXUHV,VO007680YXUJA,MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VV007680LYJKF,VV015360LYXMT, MV003200LYJKH, MV006400LYJKK.</li><li>Fix an issue that foreign drives import with invalid security key with 5 attempts causing controller into infinite loop</li><li>Fix an issue that controller may assert when there is MCTP traffic when PCI BAR update&nbsp;is in progress</li><li>Fix an issue that Redfish Drive.CapableSpeedGbs shows as 22 instead of 22.5 for SAS4 drive</li><li>Fix an issue that the number of logical drives created is less than the expected when creating multiple Logical Drive in the same command with ReuseTargetId option</li><li>Fix an intermittent issue that pinned cache may not generate in multiple logical drive Config</li><li>Fix a rare issue that offline drive firmware download timed out due to host taskmanagement but still generate download complete event</li><li>Fix an issue that RAID5/50/6/60 logical drive performance may be lower when there is cache offload happened before server bootup</li><li>Fix an issue that controller may fault and recovery with OCR (online controller reset) while running Patrol Read on NVMe drives</li><li>Fix an issue that Maximum Write Same Length or Maximum Unmap Block Descriptor Count of NVMe JBOD drive may be overwritten and cause SCSI UNMAP or WRITE SAME command failed</li><li>Fix a rare issue that UR (Unsupported Request) for PCIe Memory Read may occur when host configure PCIe BAR at run-time</li><li>Fix an issue that SCSI UNMAP command using a parameter list length greater than 0 and less than 8 would fail with SCSI Sense key Illegal Request and Additional sense data of Invalid Field in Parameter List</li><li>Fix a rare issue that controller may assert because PCI bar initialization timeouts waiting for boot message processing</li></ul>","Lang":"cn"}],"Version":"52.30.3-5917"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 GCA Drop</p>","Fixes":"","Lang":"cn"}],"Version":"52.32.3-6118"}],"SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"35ac0112a59d4a3abf760d6d81afef11"}]},{"ProductId":"8a01a8f2913f46979fa6206b3faeb0eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp; &nbsp; &nbsp; Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK7825Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp; &nbsp; &nbsp; Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"8005680","DateModified":"2025-01-11T00:19:21","FileList":["cp064860.xml","cpqsetup.exe","mnv_cli.exe","MPK7825Q.bin","payload.json","setup.dll"],"MD5Sum":"f668493e3191a4e66897ccf6ff9b4211","Name":"cp064860.exe","Release":"2025-01-11T00:15:22","Revision":"B","SHA1Sum":"573d6f34e57c6559a4962a5b7d0fe37299f11698","SHA256Sum":"62422d6ef434735af81c007c9b48e9f94b5f91506433be9aa0f1521db354d393","Size":"7MB","TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"2","Version":"MPK7825Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-0 Drives"},{"Lang":"ja","Value":"Windows（x64）用オンラインNVMe SSDフラッシュコンポーネント - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-0ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:37:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa2b788e154f4502b57b29aa07a1201d"}]},{"ProductId":"81cb1e1fa07441fc9994562f591c5c30","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8251659","DateModified":"2024-12-11T07:15:23","FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"MD5Sum":"e7d27878a39c9c34c2649444564ebf92","Name":"kmod-netxtreme2-7.15.24-1.rhel9u4.x86_64.rpm","Release":"2024-12-11T06:51:07","Revision":"","SHA1Sum":"4ea4288bc5049eba97864298b41e99e91a59fb28","SHA256Sum":"74f1ce8bcb95a95eb29c26d265b9c9ee08f7bfb4244229664033d946c7dd2a12","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.24-5"},{"Bytes":"8318650","DateModified":"2024-12-11T07:18:57","FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"MD5Sum":"91a8eb069f69b3d9148b11cd4caaccbb","Name":"kmod-netxtreme2-7.15.24-5.rhel9u5.x86_64.rpm","Release":"2024-12-11T06:51:07","Revision":"","SHA1Sum":"73a41c952cbac8009cf0724df591ffcd451f1dea","SHA256Sum":"0fd4d85e8d7ce811eaa46b99be9ad5f9aab850e0d206e77c2cacafb3f3817c4c","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.24-5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1933","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1933","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"1917","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c1917","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"3382","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c3382","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9 update 4.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Red Hat Enterprise Linux 9 Update 4をサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9 update 4.</p>","Fixes":"","Lang":"cn"}],"Version":"7.15.23-2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"7.15.24-5"}],"SWKeys":[{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a0bbb83802fd4a7288e29c12e08a28c4"}]},{"ProductId":"f12cb892007944f694736d03ec00543c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"5304690","DateModified":"2025-05-14T05:54:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/CP066524.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066524.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066524.scexe"],"MD5Sum":"40c169a75837191380e3a5d3498d288e","Name":"firmware-hdd-a07a420ed1-HPD5-5.1.x86_64.rpm","Release":"2025-05-14T10:43:09","Revision":"E","SHA1Sum":"dc7d5614aa693a6bdf544a62b2215e82e7b6d7bb","SHA256Sum":"8723b56f84a2eadd49a2a917748a96d0bdd8dc268e44868aa858a3efb9f12358","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040349.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO006400JWZJT","TargetGUID":"562340a5-304f-3630-3430-304a575a4a54","Type":"sas"},{"Id":"VO003200JWZJR","TargetGUID":"562340a5-304f-3330-3230-304a575a4a52","Type":"sas"},{"Id":"VO001600JWZJQ","TargetGUID":"562340a5-304f-3130-3630-304a575a4a51","Type":"sas"},{"Id":"VO000800JWZJP","TargetGUID":"562340a5-304f-3030-3830-304a575a4a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:11:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2ec04dc8ea434c5ba27ba4f3f78884ed"}]},{"ProductId":"b81956d2c370432aad5ffc0ea6fc40b3","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"682608","DateModified":"2025-02-11T03:34:12","FileList":["cp062883.xml","cpqsetup.exe","LICENSE.txt","payload.json","PICGen10_v1.1.4_hdr.signed.hex","SecureFlash64.dll"],"MD5Sum":"fe48120d27ee289abd2a60f88e0cc3ac","Name":"cp062883.exe","Release":"2025-02-11T03:32:32","Revision":"C","SHA1Sum":"78cd5946d8d29fbd0f6733eaae53d32df565c9a8","SHA256Sum":"6272fbe159e6cd2f0859478520fc066ae6079488d89882ab4fe72d1c1ae8d127","Size":"666KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />&nbsp;</p><p>This component can only be executed on Windows x64.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br /> </p><p>このコンポーネントは、Windows x64上でのみ実行できます。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />&nbsp;</p><p>This component can only be executed on Windows x64.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-09-21T05:18:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DX360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fb72cae827014ad78019d52dc3356f9e"}]},{"ProductId":"96d916494e7148b08fda3030539ce372","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under VMware VMware vSphere 8.0 and VMware vSphere 9.0 Only."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0およびVMware vSphere 9.0のみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under VMware VMware vSphere 8.0 and VMware vSphere 9.0 Only."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"13654857","DateModified":"2025-04-07T08:16:10","FileList":["/CP066649_BUILD_6.data","/CP066649.vmexe64","/CP066649.vmfile","/CP066649_VMw.zip","/CP066649.xml","/payload.json","/CP066649_VMw.zip/index.xml","/CP066649_VMw.zip/vendor-index.xml","/CP066649_VMw.zip/metadata.zip","/CP066649_VMw.zip/vib20/CP066649/HPE_bootbank_CP066649_1.42.0.6-8.0.0.20613240.vib","/CP066649_VMw.zip/metadata.zip/vendor-index.xml","/CP066649_VMw.zip/metadata.zip/vmware.xml","/CP066649_VMw.zip/metadata.zip/vibs/CP066649--3309729203076289434.xml","/CP066649_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066649_1.42.0.6-8.0.0.20613240.xml"],"MD5Sum":"64df6255fb66651a0ac4f286be2580c0","Name":"CP066649.zip","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"0634ec6747c049da0636b317f439f290b6eb5616","SHA256Sum":"400a5abaeae08aefc0abaf0af27aae9d98ebe92e2dfc17ae1c4bfc97558e42b7","Size":"13MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"1.42.0","VibList":[{"Name":"CP066649","Version":"1.42.0.6-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only."},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor VMware（HPE ProLiant Gen10サーバーシリーズ専用）。"},{"Lang":"cn","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:34:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"}],"SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b028e57912074629a95b12ed19622619"}]},{"ProductId":"74085bfad3ea4badb1e5c0235f47c1ea","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD4"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD4"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD4"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD4"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD4"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD4"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD4"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD4"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD4"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD4"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD4"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD3<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5879995","DateModified":"2025-05-14T06:40:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/CP066513.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/KAPM6ALSHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066513.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066513.scexe"],"MD5Sum":"1219f8cf78b73bfea586afe0ce7b8205","Name":"firmware-hdd-42aff4675b-HPD4-3.1.x86_64.rpm","Release":"2025-05-14T11:29:33","Revision":"C","SHA1Sum":"dd45779443f2bc061b1c87aa753a3f04e4f0e7e9","SHA256Sum":"2b210e962d2b8824582d860c1468d4a490fb3275ed10fa960584775f1aac7399","Size":"5MB","TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041670.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64） - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EO000800PXDCK","TargetGUID":"452340a5-304f-3030-3830-30505844434b","Type":"sas"},{"Id":"MO000800PXDBP","TargetGUID":"4d2340a5-304f-3030-3830-305058444250","Type":"sas"},{"Id":"EO000400PXDBQ","TargetGUID":"452340a5-304f-3030-3430-305058444251","Type":"sas"},{"Id":"EO001600PXDCH","TargetGUID":"452340a5-304f-3130-3630-305058444348","Type":"sas"},{"Id":"MO001600PXDCC","TargetGUID":"4d2340a5-304f-3130-3630-305058444343","Type":"sas"},{"Id":"MO006400PXDCE","TargetGUID":"4d2340a5-304f-3630-3430-305058444345","Type":"sas"},{"Id":"VO007680PXDBU","TargetGUID":"562340a5-304f-3730-3638-305058444255","Type":"sas"},{"Id":"VO001920PXDBR","TargetGUID":"562340a5-304f-3130-3932-305058444252","Type":"sas"},{"Id":"MO003200PXDCD","TargetGUID":"4d2340a5-304f-3330-3230-305058444344","Type":"sas"},{"Id":"VO015300PXDBV","TargetGUID":"562340a5-304f-3531-3330-305058444256","Type":"sas"},{"Id":"VO000960PXDBN","TargetGUID":"562340a5-304f-3030-3936-30505844424e","Type":"sas"},{"Id":"VO003840PXDBT","TargetGUID":"562340a5-304f-3330-3834-305058444254","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T03:05:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1244430680b445fa915dfe402d412f3c"}]},{"ProductId":"0300daf553df4e699178bc1f12267a1f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16980855","DateModified":"2025-06-04T05:43:15","FileList":["/BCM-storcli_007.3210.0000.0000-01_24704405.zip","/BCM_bootbank_storcli_007.3210.0000.0000-01.vib","/cp064828.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/vendor-index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/vib20/storcli/BCM_bootbank_storcli_007.3210.0000.0000-01.vib","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vibs/storcli--326648933399290352.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/bulletins/BCM-storcli_007.3210.0000.0000-01.xml"],"MD5Sum":"ca12fdd1cce5134cf8b65f8b57c43eb8","Name":"cp064828.zip","Release":"2025-06-04T05:41:56","Revision":"B","SHA1Sum":"396db336fbe4d0faffd60ea1f9cb7434567921ce","SHA256Sum":"f81f47f9267c57cf239244b6eab18d494741bfd690dd6467b63a7ffb18602113","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"storcli","Version":"007.3210.0000.0000-01"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"cn","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"ja","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.01.01"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"BCM-storcli:007.3210.0000.0000-01","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3210.0000.0000-01","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a826f60ad51b480486995629f48b6cbb"}]},{"ProductId":"f61d4171b71b4f16a99210ceeba911f6","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8312562","DateModified":"2025-04-29T13:35:36","FileList":["/CP066424_BUILD_5.data","/CP066424.vmcfg","/CP066424.vmexe64","/CP066424.vmfile","/CP066424_VMw.zip","/CP066424.xml","/payload.json","/CP066424_VMw.zip/index.xml","/CP066424_VMw.zip/vendor-index.xml","/CP066424_VMw.zip/metadata.zip","/CP066424_VMw.zip/vib20/CP066424/HPE_bootbank_CP066424_6.00.5-8.0.0.20613240.vib","/CP066424_VMw.zip/metadata.zip/vendor-index.xml","/CP066424_VMw.zip/metadata.zip/vmware.xml","/CP066424_VMw.zip/metadata.zip/vibs/CP066424-7269589702858180476.xml","/CP066424_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066424_6.00.5-8.0.0.20613240.xml"],"MD5Sum":"1b402d40d0367e0698cdbc0b65d129ea","Name":"CP066424.zip","Release":"2025-04-29T13:32:28","Revision":"F","SHA1Sum":"f09c24e78f80b50f5bc5d173afc4154f026f303c","SHA256Sum":"22272ea66275aea85a41dd62e78ce907e2183d317c0219c2f539b9544bc6156e","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00","VibList":[{"Name":"CP066424","Version":"6.00.5-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D3600B -t D3610B -t D3700B -t D3710B -v 6.00 -i Reveille-Release-6.00-build-000.bin -l D3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:06:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v266655/20-D3000B-Gen10RN600G_ED8.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b2b8ad87726c498cbbe23394855509e4"}]},{"ProductId":"b0150fa8c3c74fa8a3415a136a3cc117","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2022およびWindows Server 2025で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"6255040","DateModified":"2025-04-07T07:08:14","FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp066653.xml","cpqsetup.exe","FW/","FW/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","FW/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","FW/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","FW/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"345dc7e249b624fcf3256088bb380996","Name":"cp066653.exe","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"d66705a7472e85102302cd9a078ef56340bf8a6f","SHA256Sum":"8f1a43644a87be98118d4bc08b8b89caa8c38b22ee4d12c749f959632f825604","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"5.4.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom NX1 Online Firmware Upgrade Utility version 20.22.41 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","SWKey":"BcmNicFwUpg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"20.22.41"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NX1 1Gb Driver is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","SWKey":"b57nd60a.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li>ファームウェアのインストール後、アップデートを有効にするためにはAC電源の再投入が必要です。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:34:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"5.4.5.0"}],"SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"69093a77f0cc4164a8217c19b9fc1d64"}]},{"ProductId":"d93273aa12774694887dc3aab21ae996","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul>"},{"Lang":"ja","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qedf version 2.74.1.0</li><li>qedrntv version 3.71.62.0</li><li>qedentv version 3.71.73.0</li><li>qedi version 2.74.1.0</li></ul>"}],"Files":[{"Bytes":"5825382","DateModified":"2024-12-10T08:33:34","FileList":["/cp064342.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.73.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.62.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/vib20/qedi/QLC_bootbank_qedi_2.74.1.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/vib20/qedf/QLC_bootbank_qedf_2.74.1.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vibs/qedentv-7560609623763860292.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vibs/qedrntv-3009854720711671895.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vibs/qedi--2638315647479570014.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/vibs/qedf--2326221905299481579.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240_24397670.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.402.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b269e9c90165ae5027b9280ba0e0bc9e","Name":"cp064342.zip","Release":"2024-12-10T08:33:07","Revision":"","SHA1Sum":"b248218a09620baac959fb3e5b3207279aef3ab7","SHA256Sum":"2a8ca100575b34dbf508e34bdddbbaf4b0475ee6b1415c10781afc525a409367","Size":"5MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qedi","Version":"2.74.1.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.73.0-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.1.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8090159002bd","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-809015900220","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021d","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80901590021f","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:04:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product corrects an issue which system crashed due to hardware error.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ハードウェアエラーによりシステムがクラッシュする問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product corrects an issue which system crashed due to hardware error.</p>","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.402.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedf:2.74.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.62.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.73.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedi:2.74.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"92ac4b046410404b80844efdf8efdaea"}]},{"ProductId":"25afa565c5cd4e359629eee44baf7e64","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11708212","DateModified":"2025-05-14T21:23:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/CP067209.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/U39_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067209.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067209.scexe"],"MD5Sum":"b095329769bd0e8dfe368eb9182a9964","Name":"firmware-system-u39-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T02:12:04","Revision":"B","SHA1Sum":"e28dc7c8915ee5f5dc2aa4a5b815250ec606d0f5","SHA256Sum":"049eda4515fc286b2655f5ac5ff15b3189185e7fed53153fe3d32455d7ad028a","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合:<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T02:07:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"832e2c91e3024c15a15f6477ba86a75f"}]},{"ProductId":"640faf1092b548cf896ce4ae4d6b3ae8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JWFVNおよびMB004000JWFVP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JWFVN and MB004000JWFVP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JWFVN and MB004000JWFVP Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18133519","DateModified":"2025-03-06T10:38:02","FileList":["/CP065988_BUILD_2.data","/CP065988.vmexe64","/CP065988.vmfile","/CP065988_VMw.zip","/CP065988.xml","/payload.json","/CP065988_VMw.zip/index.xml","/CP065988_VMw.zip/vendor-index.xml","/CP065988_VMw.zip/metadata.zip","/CP065988_VMw.zip/vib20/CP065988/HPE_bootbank_CP065988_HPD4.2-1OEM.800.1.0.20613240.vib","/CP065988_VMw.zip/metadata.zip/vendor-index.xml","/CP065988_VMw.zip/metadata.zip/vmware.xml","/CP065988_VMw.zip/metadata.zip/vibs/CP065988-2294160824856869925.xml","/CP065988_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065988_HPD4.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ed423bf1772f4528efa2c1a13a8a2980","Name":"CP065988.zip","Release":"2025-03-06T10:37:17","Revision":"G","SHA1Sum":"3f5a7c3ccecb1a855f127ee2275091f8b93159b5","SHA256Sum":"9ee25752f103fa37bae71111ada93d2cd78346bb31efc1ca19ec3511cd040c2c","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065988","Version":"HPD4.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041752.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JWFVN and MB004000JWFVP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB002000JWFVN","TargetGUID":"4d2340a5-3042-3230-3030-304a5746564e","Type":"sas"},{"Id":"MB004000JWFVP","TargetGUID":"4d2340a5-3042-3430-3030-304a57465650","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:57:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JWFVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JWFVP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dcbbdacfef1b408abd0ae116f7420620"}]},{"ProductId":"2180429b88ed4e24883a75dbd70724b0","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-i40e) to (i40e). Now we revert this change from (i40e) to (<strong>hp</strong>-i40e).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-i40e and kmod-i40e are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-i40e and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-i40e-2.23.17-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-i40e）から（i40e）に変更されました。この変更を（i40e）から（<strong>hp</strong>-i40e）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-i40eとkmod-i40eはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-i40e-2.23.17-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-i40eによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-i40e) to (i40e). Now we revert this change from (i40e) to (<strong>hp</strong>-i40e).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-i40e and kmod-i40e are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-i40e-2.23.17-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-i40e and then install the updated RPM.</p>"}],"Files":[{"Bytes":"424901","DateModified":"2025-04-01T08:51:28","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-i40e","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/ff","./usr/lib/.build-id/ff/2d3a475bc9053d5093aabced93b67d2784e7e3","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"MD5Sum":"d9443b167eb55a576a44310dc528cd1c","Name":"kmod-hp-i40e-2.27.8-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T08:41:08","Revision":"","SHA1Sum":"3c5d263a5af892cb0bba5e403889e82dbada531c","SHA256Sum":"9c08931e8f35a8b94cf5805ea2e2d11a304b068edd539005a9bcf2eca6e84cb7","Size":"414KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.27.8-1"},{"Bytes":"425094","DateModified":"2025-04-01T08:47:13","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-i40e","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/74","./usr/lib/.build-id/74/b33f23161e83293f163a0abd2f9099ac1ef199","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"MD5Sum":"ed08873ee0f4b7e84c0be22736d922f3","Name":"kmod-hp-i40e-2.27.8-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T08:41:08","Revision":"","SHA1Sum":"e699e06bc6c687692919f7c2fd4287e4476d6800","SHA256Sum":"95766e3efb0b17b35d0f9329d986139d597b922f91a06df7b96630c6cdbaf2bc","Size":"415KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.27.8-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:12:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes warning message: index 1 is out of range.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、警告メッセージ「インデックス1は範囲外です」を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes warning message: index 1 is out of range.</p>","Lang":"cn"}],"Version":"2.26.8-1"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"2.27.8-1"}],"SWKeys":[{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9dcd10fb337949639b128009ac1f4133"}]},{"ProductId":"9a8025d60954436ba6fa5cef6da3dd18","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.700.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283608","DateModified":"2025-01-19T09:41:13","FileList":["payload.json","SC_DL20GEN10Plus_ME_06.00.03.700.signed.bin","SC_DL20GEN10Plus_ME_06.00.03.700.xml"],"MD5Sum":"c51d23924478c2e68bfd71e928fa7be1","Name":"SC_DL20GEN10Plus_ME_06.00.03.700.fwpkg","Release":"2025-01-19T09:39:47","Revision":"","SHA1Sum":"a39bb1375fdc882b5a4990c61ac1f203a7371d96","SHA256Sum":"3832c661cd0f50ccaca2526b7c9bf5f6a192e282c1266416d6cd140461feb8c8","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"0","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant DL20 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-09T05:26:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services(SPS)ファームウェアには、Intel製品アップデート(IPU)バージョンIPU.2024.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPSは、システムROM 2.00（02/01/2024）以降と組み合わせる必要があります。<p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU.2024.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.604"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"45b94a781129401299ae3ce0df36f8e4"}]},{"ProductId":"cd81ec29d7e54f55ab77712a180c1fe2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4689056","DateModified":"2025-01-11T00:40:13","FileList":["cp064861.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TACM6ALFGPK5.rel"],"MD5Sum":"9c0456f2489656ca788a1ccd0bf1c424","Name":"cp064861.exe","Release":"2025-01-11T00:36:24","Revision":"C","SHA1Sum":"d6252517bb0bcf7637fbf3586727703c79323318","SHA256Sum":"7f37134cdbd05cc6d211ba279cf3b0a018deb0aa63445dc9fd72f0a882b48ba5","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor Windows（x64）- KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T10:16:24","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK5"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9d059727aa5c4643b637622d0406d773"}]},{"ProductId":"5525dd3ac4024adeb1f8ec72b9fd1236","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"5118424","DateModified":"2025-05-15T11:02:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/CP066523.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/TA15SEe0HPD5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066523.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066523.scexe"],"MD5Sum":"bc6ec2a7c3223ec0a1d26094ffabcd8f","Name":"firmware-hdd-852266afdf-HPD5-8.1.x86_64.rpm","Release":"2025-05-15T15:49:07","Revision":"H","SHA1Sum":"935881baaf9a2efd5f883ddce25eb0306f2f92df","SHA256Sum":"890c340ee6f833bbedaa540e6bb5b6597027535c561a565977d573cf12341e4e","Size":"4MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP041561.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T08:32:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e1830cb53054b61ac6112a3f7838f89"}]},{"ProductId":"a2d50341a55d404a82473ce007636a93","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"13769279","DateModified":"2025-07-27T12:35:03","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/CP067522.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067522.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067522.scexe"],"MD5Sum":"b7a15548feed8a8c7c87992ace4ab74f","Name":"firmware-d8000-0130-9.1.x86_64.rpm","Release":"2025-07-27T17:22:12","Revision":"I","SHA1Sum":"5983ba8547c2156add7806e9e954365fa630b892","SHA256Sum":"c28199437dd96b932f0c38819368a160cb90a8034b22ca445688b5c8f521bed6","Size":"13MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"Installation":{"Command":"setup","CommandParams":"-t D8000 -v 0130 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff -l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D800012 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"ven_0x1590&dev_0x02db","TargetGUID":"","Type":"pcie"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T06:29:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加しました </p></li><li><p>Rhel 8.2のサポートを追加しました </p></li><li><p>SLES15 SP2のサポートを追加しました</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support of RHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v271809/20-D8000-Gen10RN0130I_ED10.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f763fc68bfcb4abea8c4932b8e938820"}]},{"ProductId":"17666522baed46e695f28d4315d6fdb8","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Windowsオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet専用アダプター</strong></td><td><strong>ファームウェアバージョン</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"22608864","DateModified":"2025-01-21T08:23:50","FileList":["cp065368.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"3e2d7a946427eacf5edd14c85b9885c0","Name":"cp065368.exe","Release":"2025-01-21T08:21:41","Revision":"A","SHA1Sum":"f531dbd1f2cd141a132ed2b2b4e3bb9889f33a01","SHA256Sum":"052ba7b01afa06660dba0de246ae85fc3c5649328c9bd5403978983af796bfd3","Size":"21MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.0.7"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-20T17:55:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1900にアップデートされました。</strong></p><ul><li>P11338-B21(HPE Ethernet 10Gb 2ポート548SFP+アダプター)</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1900には、新機能や変更は含まれていません。</strong></p>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"cn"}],"Version":"1.0.0.7"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 1.0.0.7(A):</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 1.0.0.7(A):</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 1.0.0.7(A):</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"cn"}],"Version":"1.0.0.7"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4f9a2618ea174fa2846d628e738c8f12"}]},{"ProductId":"a4fb8dc02faf478a85519ccf77530c6a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for VMware 8.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li><li>Fix with SOULAPI/SSACLI to clear MnP data and reset the predictive failure count.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for VMware 8.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li><li>Fix with SOULAPI/SSACLI to clear MnP data and reset the predictive failure count.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"19818467","DateModified":"2025-03-06T08:30:19","FileList":["/CP066023_BUILD_6.data","/CP066023.vmexe64","/CP066023.vmfile","/CP066023_VMw.zip","/CP066023.xml","/payload.json","/CP066023_VMw.zip/index.xml","/CP066023_VMw.zip/vendor-index.xml","/CP066023_VMw.zip/metadata.zip","/CP066023_VMw.zip/vib20/CP066023/HPE_bootbank_CP066023_HPG5.6-1OEM.800.1.0.20613240.vib","/CP066023_VMw.zip/metadata.zip/vendor-index.xml","/CP066023_VMw.zip/metadata.zip/vmware.xml","/CP066023_VMw.zip/metadata.zip/vibs/CP066023-4780014556907800122.xml","/CP066023_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066023_HPG5.6-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b40c669393229da68f21a54847613811","Name":"CP066023.zip","Release":"2025-03-06T08:29:38","Revision":"C","SHA1Sum":"2646db2378fee9d3092b3e5fe8eb78b5b6d0299b","SHA256Sum":"1b649ff3975327f7fda1b05e2ac0e487a07c70d9f687646eaa8835849971823d","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP066023","Version":"HPG5.6-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041496.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T08:25:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正には、SMARTレポートのコードの改善が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3517de8f98024d459a4a29c680e11ef7"}]},{"ProductId":"a9e8e46bd6de460ea736a9be4499f26a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"20408387","DateModified":"2025-03-07T06:38:54","FileList":["/CP065989_BUILD_8.data","/CP065989.vmexe64","/CP065989.vmfile","/CP065989_VMw.zip","/CP065989.xml","/payload.json","/CP065989_VMw.zip/index.xml","/CP065989_VMw.zip/vendor-index.xml","/CP065989_VMw.zip/metadata.zip","/CP065989_VMw.zip/vib20/CP065989/HPE_bootbank_CP065989_HPD2.8-1OEM.800.1.0.20613240.vib","/CP065989_VMw.zip/metadata.zip/vendor-index.xml","/CP065989_VMw.zip/metadata.zip/vmware.xml","/CP065989_VMw.zip/metadata.zip/vibs/CP065989--774525207630488700.xml","/CP065989_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065989_HPD2.8-1OEM.800.1.0.20613240.xml"],"MD5Sum":"ea4a65538a4dd1dc4d27a709d773f3bf","Name":"CP065989.zip","Release":"2025-03-07T06:38:04","Revision":"G","SHA1Sum":"8f04bf6226081cc2a0a011a495e1dbd0e1a0dd8a","SHA256Sum":"ad8c041155f8a306855ccbca64497635c597c5b81b86a8df3341d69483e481b5","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065989","Version":"HPD2.8-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041478.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:07:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"81d8c5b2beeb482ba3508dee74c64ae1"}]},{"ProductId":"77057f17d85c42018e33e3454cf6ece5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This driver package updates OFED Storage Driver for Mellanox Adapters"},{"Lang":"ja","Value":"このドライバーパッケージは、Mellanoxアダプター用のOFEDストレージドライバーをアップデートします"},{"Lang":"cn","Value":"This driver package updates OFED Storage Driver for Mellanox Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"236583088","DateModified":"2025-06-18T04:44:56","FileList":["cp067608.xml","cpqsetup.exe","MlnxDriverInstaller.dll","MLNX_WinOF2-25_4_50020_All_x64.exe"],"MD5Sum":"aed675a71157262cea70b8b0d9b137f2","Name":"cp067608.exe","Release":"2025-06-18T04:41:46","Revision":"","SHA1Sum":"c310d021553a3b17160c515d7f0bb2a68c65de05","SHA256Sum":"a3c96399194512ca2a726d88afdbadf49229c977897b3495d5e72f5e7ae8dab8","Size":"225MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.4.50020.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025"},{"Lang":"ja","Value":"HPE Mellanox OFEDストレージドライバーfor Microsoft Windows Server x64- 2019/2022/2025"},{"Lang":"cn","Value":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"101D","SubDev":"037D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d1590037d","Type":"pci","Ven":"15B3"},{"Dev":"101F","SubDev":"03FE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f159003fe","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T04:03:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version 24.10.26603.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン24.10.26603.0にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version 24.10.26603.0</p>","Fixes":"","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version 25.4.50020.0</p>","Fixes":"","Lang":"cn"}],"Version":"25.4.50020.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"85d295ce776b4eeea7d3d3f86175e6ab"}]},{"ProductId":"c41c6d23d08b454ca2ee1c24f966683f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWCBCおよびMB002000GWCBD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)-&nbsp;&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)-&nbsp;&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"6154669","DateModified":"2025-05-14T08:54:54","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/CP066539.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/WRN620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066539.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066539.scexe"],"MD5Sum":"f2f676f999ba4ccac853cd09cd1bcef3","Name":"firmware-hdd-68b12e54d2-HPG6-13.1.x86_64.rpm","Release":"2025-05-14T13:43:09","Revision":"M","SHA1Sum":"90bf4731ab93ac346de837d32ef5227b407e8a81","SHA256Sum":"1b796222403ce6171669ac6026e69514dfbf90980722f907afe1fd30852a4f2e","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP040777.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB001000GWCBC","TargetGUID":"4d2340a5-3042-3130-3030-304757434243","Type":"sata"},{"Id":"MB002000GWCBD","TargetGUID":"4d2340a5-3042-3230-3030-304757434244","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:30:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWCBC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWCBD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9b39620d09c64ffa884ea81d739d9952"}]},{"ProductId":"459b31cbafbe408eaf0a96421248c984","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp; &nbsp; &nbsp; Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK78H5Q</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp; &nbsp; &nbsp; Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"8006608","DateModified":"2025-01-11T00:15:19","FileList":["cp064856.xml","cpqsetup.exe","mnv_cli.exe","MPK78H5Q.bin","payload.json","setup.dll"],"MD5Sum":"c55b9b16c2b57027851cdce05814ddfc","Name":"cp064856.exe","Release":"2025-01-11T00:10:12","Revision":"B","SHA1Sum":"8ffb06b5673e3042418f4d62acd56917d4911e39","SHA256Sum":"2cfd8f933e8b74d05a1db7fcf160bdd93bf5249be5e3027f8f9faa72bcf09750","Size":"7MB","TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"2","Version":"MPK78H5Q"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-0ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"},{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:31:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5beba73de79140f3a2f4db85642d1486"}]},{"ProductId":"683278c3722a411eb75e30e9eb4f543d","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するIntel Ethernet NIC用のiavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1413360","DateModified":"2025-04-01T06:48:14","FileList":["cp065379.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"MD5Sum":"a30ca558b0398fa9e41410c77d413bb2","Name":"cp065379.exe","Release":"2025-04-01T06:34:04","Revision":"","SHA1Sum":"8484e027b7a9ec6096701cfe3d895f07855b3a2a","SHA256Sum":"41ba70b1e69e2fc692f214eb5e395f3dcfa5e3a32a2a578a559973e62d01614a","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel iavf Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel iavfドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel iavf Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1889","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-154c80860000","Type":"pci","Ven":"8086"},{"Dev":"1889","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-188980860000","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-21T07:58:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5 and Columbiaville 4.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5およびColumbiaville 4.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5 and Columbiaville 4.5.</p>","Fixes":"","Lang":"cn"}],"Version":"1.14.203.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6d6ab4055aee4b8e9f7e05bd4f0e0671"}]},{"ProductId":"896b673e61904db68a62db4c589536af","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.700.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2283638","DateModified":"2025-01-19T09:41:16","FileList":["payload.json","SC_ML30GEN10Plus_ME_06.00.03.700.signed.bin","SC_ML30GEN10Plus_ME_06.00.03.700.xml"],"MD5Sum":"498da34f035c12838575f6804516a4c7","Name":"SC_ML30GEN10Plus_ME_06.00.03.700.fwpkg","Release":"2025-01-19T09:40:13","Revision":"","SHA1Sum":"f61f71308381d4b71d0f2c010a0b458b2d3c3687","SHA256Sum":"654d27295c7aba5208ed7440093fe4dca77c16c78c3fd4ce9ae5f64beedbc8f0","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"0","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-09T04:42:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services(SPS)ファームウェアには、Intel製品アップデート(IPU)バージョンIPU.2024.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPSは、システムROM 2.00（02/01/2024）以降と組み合わせる必要があります。<p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>機能強化/新しい機能：</strong></p><p>このバージョンは、IPU.2024.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2024.1 guidance.This version of the SPS should be paired with System ROM 2.00 (02/01/2024) or later.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2024.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.604"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"feccfbec705146c1bd7c4df6f00de744"}]},{"ProductId":"2e5a37814cc1401a951db2b5be91b6b3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK7"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK7"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK7"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK7"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK7"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACD6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6289218","DateModified":"2025-05-14T06:14:05","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/CP066533.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/TACD6ALLGPK7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK7-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066533.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066533.scexe"],"MD5Sum":"e3e8afcbf7d9c911afec2d0945c2dfc4","Name":"firmware-hdd-6fc985bd3b-GPK7-8.1.x86_64.rpm","Release":"2025-05-14T11:01:05","Revision":"H","SHA1Sum":"bcc675e604d256c3dc1e536ef04c653f360f674a","SHA256Sum":"29a7d7e2ea4fa2c371f9cef86cdf7e6eabcd6eb44c6ce560efdc1641cbf4dc54","Size":"5MB","TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK7"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCD6XLUL7T68","TargetGUID":"002340a5-434b-3644-584c-554c37543638","Type":"nvme"},{"Id":"KCD6XVUL6T40","TargetGUID":"002340a5-434b-3644-5856-554c36543430","Type":"nvme"},{"Id":"KCD6XVUL1T60","TargetGUID":"002340a5-434b-3644-5856-554c31543630","Type":"nvme"},{"Id":"KCD6XVUL800G","TargetGUID":"002340a5-434b-3644-5856-554c38303047","Type":"nvme"},{"Id":"KCD6XVUL3T20","TargetGUID":"002340a5-434b-3644-5856-554c33543230","Type":"nvme"},{"Id":"KCD6XLUL960G","TargetGUID":"002340a5-434b-3644-584c-554c39363047","Type":"nvme"},{"Id":"KCD6XLUL1T92","TargetGUID":"002340a5-434b-3644-584c-554c31543932","Type":"nvme"},{"Id":"KCD6XLUL3T84","TargetGUID":"002340a5-434b-3644-584c-554c33543834","Type":"nvme"},{"Id":"KCD6XVUL12T8","TargetGUID":"002340a5-434b-3644-5856-554c31325438","Type":"nvme"},{"Id":"KCD6XLUL15T3","TargetGUID":"002340a5-434b-3644-584c-554c31355433","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:08:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a339eb95e85748fab0c7ea97b45b345c"}]},{"ProductId":"7cb9f47fb1de402da9399ef94a8426a5","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a575a5651","Version":"HPD3"},{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a575a5652","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model:  MB006000JWZVQ and MB008000JWZVR"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB006000JWZVQおよびMB008000JWZVR"},{"Lang":"cn","Value":"This package provides firmware for the following drive model:  MB006000JWZVQ and MB008000JWZVR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPD3<br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;&nbsp; </strong>N/A<br /><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp;</strong>N/A<br /><strong>Enhancements/New Features:<br />&nbsp; &nbsp; &nbsp;</strong>None<br /><strong>Problems Fixed:<br />&nbsp; &nbsp; &nbsp;</strong>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong>None</p>"}],"Files":[{"Bytes":"1311475","DateModified":"2025-02-19T21:07:21","FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAeD3.HPb","Toshiba_MG08Air_TAMG08SDAeD3.xml"],"MD5Sum":"f523c1f7b1d48fd5037d45968bee5c6f","Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","Release":"2025-02-19T21:04:31","Revision":"B","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB006000JWZVQおよびMB008000JWZVR"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000JWZVQ","TargetGUID":"4d2340a5-3042-3630-3030-304a575a5651","Type":"sas"},{"Id":"MB008000JWZVR","TargetGUID":"4d2340a5-3042-3830-3030-304a575a5652","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T21:04:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions..</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。  このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp; The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions..</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB006000JWZVQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB008000JWZVR","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"6927e5439b7746e3bda2359045abc5bb"}]},{"ProductId":"8bf9eb4134cf48c2a7da72633124722f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1544112","DateModified":"2025-04-01T02:20:14","FileList":["cp065292.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"c9cead8a6ff7f55adb7fb9ccfca649f1","Name":"cp065292.exe","Release":"2025-04-01T02:06:04","Revision":"","SHA1Sum":"c8980230ed7ff56f4d4fa3b2ea49960dc23d6a5f","SHA256Sum":"a957aa43683a38e78bbcdfaf75fd23dbf2e3aa2e719243289475327329a0962d","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40eb Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel i40ebドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel i40eb Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:39:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.267.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"444ada6a3b8a405f83a72b466c583f05"}]},{"ProductId":"5410a19b6b464f26bd8935266bc1120d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33609089","DateModified":"2025-04-18T13:35:13","FileList":["payload.json","U39_3.50_04_17_2025.signed.flash","U39_3.50_04_17_2025.xml"],"MD5Sum":"892898646e9f84a893688a10faa101e4","Name":"U39_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"638c15d2e1280d94b0e5676189435ed450c28b43","SHA256Sum":"da481a38bf971394bd9197d301b3c676946ff4b6b12c8385bc2b23c8008a939b","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"2dbdccfe63fa4fd7b69a8b6f21d37159"}]},{"ProductId":"a2c850b33a31462c8693efedafbdd8b9","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.23"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.23.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.23"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"此软件包含有用于升级在Linux x86_64平台下运行的HPE ProLiant QLogic FastLinQ千兆以太网卡固件所需的实用程序和二进制文件。"},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2249949","DateModified":"2024-12-11T03:24:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/CP064336.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/CP064336.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/nic_fw/ql_hp_ah_mbi_8.65.23.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.25.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064336.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064336.scexe"],"MD5Sum":"dcae69d67ccc1e59457eb5915ec1c948","Name":"firmware-nic-qlogic-flq-1.25.0-1.1.x86_64.rpm","Release":"2024-12-11T09:17:07","Revision":"","SHA1Sum":"3ff8b8a1520bc549cf284e98cebedcd775e31567","SHA256Sum":"c42e85a088c9dc5a1bc5ec2aee46f5a6d45e67754c638ec5b43085046ff47a8b","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"1.25.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報:</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェア8.35.43は、'HPE Ethernet 10/25Gb 2ポート622FLR-SFP28コンバージドネットワークアダプター'の追加のネットワーク機能を実現することに注意してください。したがって、アダプターを8.35.43またはそれ以降にアップデートすると、バージョン8.35.43よりも古いバージョンにダウングレードすることはできません。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"适用于 Linux x86_64 的 HPE QLogic FastLinQ 在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.24.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"1.25.0"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"07e3ad2fd19e4089b75a0d065c01fba9"}]},{"ProductId":"c9a566daebdb4bd4a0f22d28877b9f3b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"cn","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"cn","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"},{"Lang":"ja","Value":"<p>This product contains the following drivers:</p><ul><li>qfle3 version 1.4.51.0</li><li>qcnic version 2.0.67.0</li><li>qfle3i version 2.1.14.0</li><li>qfle3f version 2.1.34.0</li></ul>"}],"Files":[{"Bytes":"1521204","DateModified":"2024-12-10T08:29:42","FileList":["/cp064706.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"MD5Sum":"a7a16c4d0961276292bc0a9f6a333f20","Name":"cp064706.zip","Release":"2024-12-10T08:29:21","Revision":"","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","Size":"1MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-09T05:38:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5b72663a36ec4ac2a8e3084a2ac63e87"}]},{"ProductId":"c6a4f7a1c0f14173802a4263b3ee7551","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG6<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes a false indication of rare capacitor test failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5299244","DateModified":"2025-05-14T04:45:30","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/CP066567.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066567.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066567.scexe"],"MD5Sum":"c14ef0c768d708967c177404cddc269a","Name":"firmware-hdd-c566d63ca0-HPG7-5.1.x86_64.rpm","Release":"2025-05-14T09:32:24","Revision":"E","SHA1Sum":"d8e4b20693a230c1e65ce76379919ef149b5cee2","SHA256Sum":"7b6555ca456c6f1e76482a20d430a45076a1c195bffe73e89070cf9f1b15bb38","Size":"5MB","TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"Installation":{"Command":"CP040783.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTTD","TargetGUID":"562340a5-304b-3330-3834-304757545444","Type":"sata"},{"Id":"MK003840GWTTN","TargetGUID":"4d2340a5-304b-3330-3834-30475754544e","Type":"sata"},{"Id":"VK001920GWTTC","TargetGUID":"562340a5-304b-3130-3932-304757545443","Type":"sata"},{"Id":"MK001920GWTTL","TargetGUID":"4d2340a5-304b-3130-3932-30475754544c","Type":"sata"},{"Id":"VK000960GWTTB","TargetGUID":"562340a5-304b-3030-3936-304757545442","Type":"sata"},{"Id":"MK000960GWTTK","TargetGUID":"4d2340a5-304b-3030-3936-30475754544b","Type":"sata"},{"Id":"VK000480GWTTA","TargetGUID":"562340a5-304b-3030-3438-304757545441","Type":"sata"},{"Id":"MK000480GWTTH","TargetGUID":"4d2340a5-304b-3030-3438-304757545448","Type":"sata"},{"Id":"VK000240GWTSV","TargetGUID":"562340a5-304b-3030-3234-304757545356","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:18:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG7"}],"SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1576a5d37927409fb8a4ff16f3f8236f"}]},{"ProductId":"6ee949809c8346d9b5134787ab827a8a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Assert fixes, logging enhancements and all current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Assert fixes, logging enhancements and all current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"6217272","DateModified":"2025-05-14T08:16:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/CP066558.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/SHPEEVSBPSD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD3-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066558.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066558.scexe"],"MD5Sum":"8357f27ff5bb63f7a616138fd7df9283","Name":"firmware-hdd-8173816d98-HPD3-4.1.x86_64.rpm","Release":"2025-05-14T13:05:04","Revision":"D","SHA1Sum":"51ffb86440419c8a69813a91e0f2873e690aecd6","SHA256Sum":"b85706ef418b20e8fca936a09f2740622dc880b715620df9bd4d339fad1382b0","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:53:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1455fcb709f34d93987be8eb07076918"}]},{"ProductId":"eafab624995d485096ba1119b617b464","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7936519","DateModified":"2024-12-11T07:44:22","FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/bnx2.ko","./lib/modules/5.14.21-150500.53-default/updates/bnx2fc.ko","./lib/modules/5.14.21-150500.53-default/updates/bnx2i.ko","./lib/modules/5.14.21-150500.53-default/updates/bnx2x.ko","./lib/modules/5.14.21-150500.53-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"MD5Sum":"b36dbeb88f1aea4f4ca383f39883d161","Name":"netxtreme2-kmp-default-7.15.24_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2024-12-11T07:20:05","Revision":"","SHA1Sum":"11d2d91118d546e34a6dbaf61ae725ebe47ed3e7","SHA256Sum":"5f5af0c771e179412201549a035ad0151433779df49a0c3a7ed0ed77b1874643","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.24-1"},{"Bytes":"8559120","DateModified":"2024-12-11T07:47:56","FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnx2.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2i.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2x.ko","./lib/modules/6.4.0-150600.21-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"MD5Sum":"c26901348f0c78a90676970302cb3c4e","Name":"netxtreme2-kmp-default-7.15.24_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2024-12-11T07:20:05","Revision":"","SHA1Sum":"f9c9a91e8e90506c37c800626392e47270e842f0","SHA256Sum":"aa8e49f794f9cd17dd0b16390c079ac22f5edc2cddceae266db5fc51003b6091","Size":"8MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.24-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AF","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AF","SubDev":"1933","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16af103c1933","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"1917","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ad103c1917","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"3382","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c3382","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"},{"Dev":"16AD","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16ad159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"cn"}],"Version":"7.15.23-2"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"7.15.24-1"}],"SWKeys":[{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d1db23105b874af7ae5e98a35c480f4c"}]},{"ProductId":"ed7a5d4d2f9c4a55ba7dea78369f1389","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Windows Server 2022用 HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1098832","DateModified":"2025-04-07T02:39:12","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp066623.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"4e9acaa6df372929c7e8a57e88a59f41","Name":"cp066623.exe","Release":"2025-04-07T02:24:59","Revision":"","SHA1Sum":"0249c8eea7980c4954f345eed9f1f572ac81cb50","SHA256Sum":"004b913cc9a0c800223d3b5e3412bd409b67a5346ab4a35b481e92ee36c7ff57","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"233.0.148.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、NXEファミリデバイスの一貫したPTPクロックのレポートを強化します。</li><li>この製品は、必要なPNP IDを追加することでデバイスの互換性を強化します。</li></ul>","Fixes":"<p>この製品は、未使用のrelease.txtファイルが削除されない問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"cn"}],"Version":"232.0.155.7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.148.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"847f832b27f24345ac1b3066536972b8"}]},{"ProductId":"b64e2e4187274c5798b3aa127c50ba6a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16821396","DateModified":"2025-05-21T01:26:44","FileList":["payload.json","U43_3.60_05_16_2025.signed.flash","U43_3.60_05_16_2025.xml"],"MD5Sum":"fbd4768c7ab5e0627d0e582038a44791","Name":"U43_3.60_05_16_2025.fwpkg","Release":"2025-05-21T01:23:27","Revision":"","SHA1Sum":"52efa779edc2187dd1e8eea52164ef05aa64405a","SHA256Sum":"9f1bf7f9baefd351b526e95106f6e29b0c9e5b906cb709c913d6ad28145b048a","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10(U43)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:44:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance.</p><p>&nbsp;</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p>&nbsp;</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。</p><p> </p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p> </p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance.</p><p>&nbsp;</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p>&nbsp;</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"11158899605f45818d289f127fdc6b83"}]},{"ProductId":"4899e6b54e3941a4b9c3090a539cf6db","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Controller"},{"Lang":"ja","Value":"ソフトウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"软件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Overview:</strong><br />==========<br />1. In ESXi8.0, Direct utility execution is not permitted because of mandatory security policy enforcement in ESXi 8.0.<br />2. ESXi8.0 mandates the usage of esxcli plugin for utilities. Hence esxcli plugins need to be created for all the corresponding StorCLI command set.&nbsp;</p><p>&nbsp;</p><p><strong>Existing command output/VIB behavior changes:</strong><br />==============================================<br />1. System reboot is required for changes to take effect post VIB installation. This is because of the esxcli plugin support. StorCLI namespace needs to be registered with esxcli and hence a system reboot is the mandatory step per VMware for changes to take effect.<br />2. If StorCLI utility is directly executed, Command output will be in XML format with XML encoded special characters in place.</p><p>&nbsp;</p><p><strong>Files access / permissions:</strong><br />============================<br />1. By default, CLI log file or any files, which are generated by plugin, will be created under /var/log/vmware/ directory.<br />2. An absolute file path needs to be provided for any plugins which take file as an input.</p><p>&nbsp;</p><p><strong>Limitations:</strong><br />=============<br />1. &nbsp;Memory and temp file reservation for storcli is restricted to 100MB in ESXi8.0. Hence if this memory / temp file reservation is exhausted, Plugin will not be able to parse the data correctly. Hence please make sure that the mentioned amount of memory is reserved.<br />2. &nbsp;Direct StorCLI utility command execution will yield a XML formatted output which aligns to XML rule set.<br />3. &nbsp;Command options / command / namespaces in ESXCLI plugin are case sensitive. Hence plugin should be executed based on the help mentioned for each of the esxcli plugin else esxcli plugin will error out.<br />4. &nbsp;ESXCLI plugin has a command output data limit. If this exceeds, Plugin will not parse and display the information. If the command output length is more, Please use the file option to store the data instead else please follow the below instructions from VMware to increase the data limit.</p><p>&nbsp;</p><p><strong>Steps to increase the command data limit:</strong><br />=========================================<br />1. Run the following command on the host in question: configstorecli config current get -c esx -g services -k hostd &gt; out.json<br />2. Try bumping the limits in the below in VMOMI adapter and see if it helps when running esxcli.</p><p>&nbsp; &nbsp; &nbsp; &quot;vmomi&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&quot;soap_request&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_elements&quot;: 500000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_depth&quot;: 1000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_unauthenticated_doc_size&quot;: 100000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_doc_size&quot;: 20000000<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;}<br />&nbsp; &nbsp; &nbsp; },<br />3. Then in the resulting out.json file find the entries above and bump the limits, e.g. double max_elements, max_depth and max_doc_size.<br />4. Finally, reapply:<br />&nbsp; &nbsp;configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. Reboot the server.</p><p>&nbsp;</p><p><strong>Additional notes:</strong><br />=================<br />1. For system namespace i.e., esxcli storcli system &lt;&gt;, except the esxcli storcli system file &lt;&gt; plugin, Options --json and --nolog are valid.&nbsp;<br />&nbsp; &nbsp;These options are not displayed in esxcli plugin help because these options are optional and there are no mandatory options for these set of commands.<br />2. The command options to the plugins are maintained in lower case as they are case sensitive. &nbsp;<br />3. The command options are presented in alphabetical order of the parameter name. It&#39;s per the esxcli plugin convention/rules.<br />4. Input value needs to be enclosed in double quotes if format of the value has a space.<br />5. Help command is not added as the esxcli plugin framework offers help based on the available namespaces and corresponding commands/command options can be queried accordingly.</p><p>&nbsp;</p><p><strong>ESXCLI Plugin format:</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>Example : esxcli storcli system show ctrlcount</p><p>&nbsp;</p><p><strong>ESXCLI plugin sample command output:</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"},{"Lang":"cn","Value":"<p><strong>Overview:</strong><br />==========<br />1. In ESXi8.0, Direct utility execution is not permitted because of mandatory security policy enforcement in ESXi 8.0.<br />2. ESXi8.0 mandates the usage of esxcli plugin for utilities. Hence esxcli plugins need to be created for all the corresponding StorCLI command set.&nbsp;</p><p>&nbsp;</p><p><strong>Existing command output/VIB behavior changes:</strong><br />==============================================<br />1. System reboot is required for changes to take effect post VIB installation. This is because of the esxcli plugin support. StorCLI namespace needs to be registered with esxcli and hence a system reboot is the mandatory step per VMware for changes to take effect.<br />2. If StorCLI utility is directly executed, Command output will be in XML format with XML encoded special characters in place.</p><p>&nbsp;</p><p><strong>Files access / permissions:</strong><br />============================<br />1. By default, CLI log file or any files, which are generated by plugin, will be created under /var/log/vmware/ directory.<br />2. An absolute file path needs to be provided for any plugins which take file as an input.</p><p>&nbsp;</p><p><strong>Limitations:</strong><br />=============<br />1. &nbsp;Memory and temp file reservation for storcli is restricted to 100MB in ESXi8.0. Hence if this memory / temp file reservation is exhausted, Plugin will not be able to parse the data correctly. Hence please make sure that the mentioned amount of memory is reserved.<br />2. &nbsp;Direct StorCLI utility command execution will yield a XML formatted output which aligns to XML rule set.<br />3. &nbsp;Command options / command / namespaces in ESXCLI plugin are case sensitive. Hence plugin should be executed based on the help mentioned for each of the esxcli plugin else esxcli plugin will error out.<br />4. &nbsp;ESXCLI plugin has a command output data limit. If this exceeds, Plugin will not parse and display the information. If the command output length is more, Please use the file option to store the data instead else please follow the below instructions from VMware to increase the data limit.</p><p>&nbsp;</p><p><strong>Steps to increase the command data limit:</strong><br />=========================================<br />1. Run the following command on the host in question: configstorecli config current get -c esx -g services -k hostd &gt; out.json<br />2. Try bumping the limits in the below in VMOMI adapter and see if it helps when running esxcli.</p><p>&nbsp; &nbsp; &nbsp; &quot;vmomi&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&quot;soap_request&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_elements&quot;: 500000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_depth&quot;: 1000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_unauthenticated_doc_size&quot;: 100000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_doc_size&quot;: 20000000<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;}<br />&nbsp; &nbsp; &nbsp; },<br />3. Then in the resulting out.json file find the entries above and bump the limits, e.g. double max_elements, max_depth and max_doc_size.<br />4. Finally, reapply:<br />&nbsp; &nbsp;configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. Reboot the server.</p><p>&nbsp;</p><p><strong>Additional notes:</strong><br />=================<br />1. For system namespace i.e., esxcli storcli system &lt;&gt;, except the esxcli storcli system file &lt;&gt; plugin, Options --json and --nolog are valid.&nbsp;<br />&nbsp; &nbsp;These options are not displayed in esxcli plugin help because these options are optional and there are no mandatory options for these set of commands.<br />2. The command options to the plugins are maintained in lower case as they are case sensitive. &nbsp;<br />3. The command options are presented in alphabetical order of the parameter name. It&#39;s per the esxcli plugin convention/rules.<br />4. Input value needs to be enclosed in double quotes if format of the value has a space.<br />5. Help command is not added as the esxcli plugin framework offers help based on the available namespaces and corresponding commands/command options can be queried accordingly.</p><p>&nbsp;</p><p><strong>ESXCLI Plugin format:</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>Example : esxcli storcli system show ctrlcount</p><p>&nbsp;</p><p><strong>ESXCLI plugin sample command output:</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"},{"Lang":"ja","Value":"<p><strong>Overview:</strong><br />==========<br />1. In ESXi8.0, Direct utility execution is not permitted because of mandatory security policy enforcement in ESXi 8.0.<br />2. ESXi8.0 mandates the usage of esxcli plugin for utilities. Hence esxcli plugins need to be created for all the corresponding StorCLI command set.&nbsp;</p><p>&nbsp;</p><p><strong>Existing command output/VIB behavior changes:</strong><br />==============================================<br />1. System reboot is required for changes to take effect post VIB installation. This is because of the esxcli plugin support. StorCLI namespace needs to be registered with esxcli and hence a system reboot is the mandatory step per VMware for changes to take effect.<br />2. If StorCLI utility is directly executed, Command output will be in XML format with XML encoded special characters in place.</p><p>&nbsp;</p><p><strong>Files access / permissions:</strong><br />============================<br />1. By default, CLI log file or any files, which are generated by plugin, will be created under /var/log/vmware/ directory.<br />2. An absolute file path needs to be provided for any plugins which take file as an input.</p><p>&nbsp;</p><p><strong>Limitations:</strong><br />=============<br />1. &nbsp;Memory and temp file reservation for storcli is restricted to 100MB in ESXi8.0. Hence if this memory / temp file reservation is exhausted, Plugin will not be able to parse the data correctly. Hence please make sure that the mentioned amount of memory is reserved.<br />2. &nbsp;Direct StorCLI utility command execution will yield a XML formatted output which aligns to XML rule set.<br />3. &nbsp;Command options / command / namespaces in ESXCLI plugin are case sensitive. Hence plugin should be executed based on the help mentioned for each of the esxcli plugin else esxcli plugin will error out.<br />4. &nbsp;ESXCLI plugin has a command output data limit. If this exceeds, Plugin will not parse and display the information. If the command output length is more, Please use the file option to store the data instead else please follow the below instructions from VMware to increase the data limit.</p><p>&nbsp;</p><p><strong>Steps to increase the command data limit:</strong><br />=========================================<br />1. Run the following command on the host in question: configstorecli config current get -c esx -g services -k hostd &gt; out.json<br />2. Try bumping the limits in the below in VMOMI adapter and see if it helps when running esxcli.</p><p>&nbsp; &nbsp; &nbsp; &quot;vmomi&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&quot;soap_request&quot;: {<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_elements&quot;: 500000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_depth&quot;: 1000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_unauthenticated_doc_size&quot;: 100000,<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &quot;max_doc_size&quot;: 20000000<br />&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;}<br />&nbsp; &nbsp; &nbsp; },<br />3. Then in the resulting out.json file find the entries above and bump the limits, e.g. double max_elements, max_depth and max_doc_size.<br />4. Finally, reapply:<br />&nbsp; &nbsp;configstorecli config current set -c esx -g services -k hostd -infile out.json<br />5. Reboot the server.</p><p>&nbsp;</p><p><strong>Additional notes:</strong><br />=================<br />1. For system namespace i.e., esxcli storcli system &lt;&gt;, except the esxcli storcli system file &lt;&gt; plugin, Options --json and --nolog are valid.&nbsp;<br />&nbsp; &nbsp;These options are not displayed in esxcli plugin help because these options are optional and there are no mandatory options for these set of commands.<br />2. The command options to the plugins are maintained in lower case as they are case sensitive. &nbsp;<br />3. The command options are presented in alphabetical order of the parameter name. It&#39;s per the esxcli plugin convention/rules.<br />4. Input value needs to be enclosed in double quotes if format of the value has a space.<br />5. Help command is not added as the esxcli plugin framework offers help based on the available namespaces and corresponding commands/command options can be queried accordingly.</p><p>&nbsp;</p><p><strong>ESXCLI Plugin format:</strong><br />======================</p><p>esxcli [options] {namespace}+ {cmd} [cmd options]</p><p>Example : esxcli storcli system show ctrlcount</p><p>&nbsp;</p><p><strong>ESXCLI plugin sample command output:</strong><br />=====================================<br />esxcli storcli system show ctrlcount<br />CLI Version = 007.2417.0000.0000 Apr 21, 2023<br />Operating system = VMkernel8.0.0<br />Status Code = 0<br />Status = Success<br />Description = None</p><p>Controller Count = 1</p>"}],"Files":[{"Bytes":"16984191","DateModified":"2025-06-04T05:53:32","FileList":["/BCM-storcli_007.3210.0000.0000-01_24704405.zip","/BCM_bootbank_storcli_007.3210.0000.0000-01.vib","/cp064826.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/vendor-index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/vib20/storcli/BCM_bootbank_storcli_007.3210.0000.0000-01.vib","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/vibs/storcli--326648933399290352.xml","/BCM-storcli_007.3210.0000.0000-01_24704405.zip/metadata.zip/bulletins/BCM-storcli_007.3210.0000.0000-01.xml"],"MD5Sum":"678c85f15dc3c27fa1f05fb1ed125d85","Name":"cp064826.zip","Release":"2025-06-04T05:52:15","Revision":"C","SHA1Sum":"46bddddd5c121aae6d51fc014996e2f3c18dcaa9","SHA256Sum":"a22199650260606212884afd307a791001ec63f08e3f69fcda473229b3702ac1","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"storcli","Version":"007.3210.0000.0000-01"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"cn","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"},{"Lang":"ja","Value":"<p><strong>Installing VIBs on the ESXi 9.0 host from the ESXi shell:</strong></p><ul><li>Transfer the VIB(s) onto the ESXi host local path</li><li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;</strong><strong> </strong></li><li>For unsigned binary&nbsp;--no-sig-check parameter to be passed with&nbsp;install command</li><li><strong># esxcli software vib install -d &lt;path&gt;&lt;componet_bundle&gt;&nbsp;--no-sig-check</strong></li></ul><p><strong>VIB Package can be removed using the command</strong></p><ul><li><strong># esxcli software vib remove -n&nbsp;&lt;filename&gt;</strong></li><li>Use the command to list the installed&nbsp;vib file name,<strong> # esxcli software vib list | grep storcli</strong></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいGen12 サーバーをサポートします。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.01.01"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"BCM-storcli:007.3210.0000.0000-01","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3210.0000.0000-01","SWKeyExpectedPath":"software:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6e6378231c4a4296811558adc81021ec"}]},{"ProductId":"eca7d77c8ba84ffe9014dfb5c3b6ee15","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWCPK、EH000600JWCPL、EH000300JWCPN、EH000300JXLVR、EH000600JXLVT、EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5929301","DateModified":"2025-05-14T07:03:26","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/CP066551.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066551.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066551.scexe"],"MD5Sum":"d10a3c37d715d76363a740db11d4f6d7","Name":"firmware-hdd-3d97759111-HPDB-3.1.x86_64.rpm","Release":"2025-05-14T11:50:24","Revision":"C","SHA1Sum":"d49843f260004e4956ea737d9bda39be16058734","SHA256Sum":"e3849088d580371ba39823a6c366329e6d9f4250290ce7cbacd0c1ce166d82ef","Size":"5MB","TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"CP040309.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EH000300JWCPK、EH000600JWCPL、EH000900JWCPN、EH000300JXLVR、EH000600JXLVT、およびEH000900JXLVUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T14:44:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"428ced0638264cb2b4d5c1e002477e97"}]},{"ProductId":"bc3fe657ed304b17aeeab14dfddb1656","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5138736","DateModified":"2025-04-04T06:47:13","FileList":["Config.xml","cp066426.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-6.00-build-000.bin","VDUFlash.dll"],"MD5Sum":"8b15a0f47f79b8701693c3823d9b8043","Name":"cp066426.exe","Release":"2025-04-04T06:45:51","Revision":"F","SHA1Sum":"3c7b0dd601e2955b22e926dc88cfcb276bf8cfd7","SHA256Sum":"d03d6b0d07f05c2ba94ba349eb4882065e51ca51312951e371937c0ad647ccb8","Size":"4MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD3600B /tD3700B /tD3610B /tD3710B /v6.00 /iReveille-Release-6.00-build-000.bin /lD3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:09:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v264145/20-D3000B-Gen10RN600F_ED7.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"006b6cc785d24386a71a557cafff41a1"}]},{"ProductId":"8796bf21e8204a0da4179cfbcd105e85","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 9 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 9 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 9 64-bit to enable the HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"123737","DateModified":"2025-04-25T05:37:51","FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"MD5Sum":"8068b3090bec029fe1d5a1cac83f5b7a","Name":"kmod-megaraid_sas-07.732.03.00_rhel9u4-1.x86_64.rpm","Release":"2025-04-25T05:31:10","Revision":"B","SHA1Sum":"7c45c35517750b08050386242a767a4484338af2","SHA256Sum":"dd854b791098d4dc01af1fd49d28d5b10ca6dc96c77f75cad2a38925f774ea42","Size":"120KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.732.03.00"},{"Bytes":"124526","DateModified":"2025-04-25T05:42:07","FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"MD5Sum":"ffa1bb3c4da392a63726c45d130f42c0","Name":"kmod-megaraid_sas-07.732.03.00_rhel9u5-1.x86_64.rpm","Release":"2025-04-25T05:31:10","Revision":"B","SHA1Sum":"0adaaedab1e68158f8f8fa936d52efb093d40a50","SHA256Sum":"b2cc7e403ae120a7ee9c00739ed85b004a2cc49e575e0bde84529d0759be69e1","Size":"121KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.732.03.00"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To install the driver, type the following command:<br /># rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel9uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p><p>A REBOOT is required for your computer when the setup is complete.</p>"},{"Lang":"ja","Value":"<p>To install the driver, type the following command:<br /># rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel9uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p><p>A REBOOT is required for your computer when the setup is complete.</p>"},{"Lang":"cn","Value":"<p>To install the driver, type the following command:<br /># rpm --Uvh&nbsp;--oldpackage --replacefiles --replacepkgs kmod-megaraid_sas-X.X.X.X-X.rhel9uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p><p>A REBOOT is required for your computer when the setup is complete.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"LSI Logic Corporation"},{"Lang":"ja","Value":"LSI Logic Corporation"},{"Lang":"cn","Value":"LSI Logic Corporation"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいGen12 サーバーをサポートします。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"07.730.01.00"},{"ReleaseNotes":[{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"cn"}],"Version":"07.732.03.00"}],"SWKeys":[{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a1c14ed9dbe14eae9f68734b59f20e91"}]},{"ProductId":"635ad6621b8d4c52b8b9de3325345e84","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.01"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.01"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.01"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021101.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.01"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters. "},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3840048","DateModified":"2025-06-24T11:48:19","FileList":["QLAFWUpdate.exe","adapters.properties","bk020501.bin","cp067638.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021101.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"MD5Sum":"ef41676853a1bd7d95262a858e6405ec","Name":"cp067638.exe","Release":"2025-06-24T11:33:11","Revision":"","SHA1Sum":"4ae3dcc4a1d18e28f9098e222bc9d71a7492d066","SHA256Sum":"7f32e84b60a4b7364a7cf42da310e2092abddf106806d5c5325926fc533b879e","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.05.02"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":250,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"ja","Value":"HPEファームウェアフラッシュfor QLogicファイバーチャネルホストバスアダプター - Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-24T08:56:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.02"}],"SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a73b64edfb434afe9def346412dd9d10"}]},{"ProductId":"e9b531c475a54ce6b287402b5c425933","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064844.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.005"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2177955","DateModified":"2025-01-17T01:42:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/CP064846.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/cp064844.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/cp064844.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.005-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064846.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064846.scexe"],"MD5Sum":"a7c7fb7de49d1e709f94c8c655dbd885","Name":"firmware-dl20ml30gen10sps-05.01.05.005-1.1.x86_64.rpm","Release":"2025-01-17T07:35:23","Revision":"","SHA1Sum":"922375e5ed0c7c791b0775797a21b96361dcd4e8","SHA256Sum":"bd14060712663a78a6d1e782af7535835130bd32603a6850fba50b94b1da7578","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"0","Version":"05.01.05.005"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-01-18T01:31:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS)ファームウェアには、インテル製品アップデート(IPU)バージョンIPU.2023.3ガイダンスに沿ったアップデートが含まれています。<p><strong>ファームウェアの依存関係：</strong></p>なし        <p><strong>改善点/新しい機能：</strong></p><p>このバージョンは、IPU.2023.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし        ","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with Intel IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.04.913"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 05.01.05.005 should be paired with System ROM 3.50 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"05.01.05.005"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8c22f1bdc3114f7e81eb9185eedc1670"}]},{"ProductId":"9141b4ee76c74b70a4eb2f021bfa217f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV "},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3236672","DateModified":"2025-01-11T08:21:14","FileList":["cp065076.xml","cpqsetup.exe","KAPM5ALSHPDB.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"8d5f71f98518b25c21d78b6d1204be88","Name":"cp065076.exe","Release":"2025-01-11T08:16:54","Revision":"C","SHA1Sum":"e2027ff4675e90209d7e047977662c5beccefeb0","SHA256Sum":"41f0210be914d6b888ad0ac59c89533a11072a67ab327db4c905c9a89b226d93","Size":"3MB","TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネントfor Windows (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T05:50:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9c3866d8a0c644ed9881effe46ffeb86"}]},{"ProductId":"23ed237c56c047b39f75b9977e930a45","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19902900","DateModified":"2025-03-07T11:22:00","FileList":["/CP065973_BUILD_3.data","/CP065973.vmexe64","/CP065973.vmfile","/CP065973_VMw.zip","/CP065973.xml","/payload.json","/CP065973_VMw.zip/index.xml","/CP065973_VMw.zip/vendor-index.xml","/CP065973_VMw.zip/metadata.zip","/CP065973_VMw.zip/vib20/CP065973/HPE_bootbank_CP065973_HPD4.3-1OEM.800.1.0.20613240.vib","/CP065973_VMw.zip/metadata.zip/vendor-index.xml","/CP065973_VMw.zip/metadata.zip/vmware.xml","/CP065973_VMw.zip/metadata.zip/vibs/CP065973--5253502155574354171.xml","/CP065973_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065973_HPD4.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5d11351acc23b4ddd891a86c645777a8","Name":"CP065973.zip","Release":"2025-03-07T11:21:04","Revision":"C","SHA1Sum":"ce68325d6bbd9b3cf3f4f05e42ccb53505d207a8","SHA256Sum":"1f0f83cf664bdde258edd8d0bea17306b03ef7ab5f2068902f63c4bfb8ebbf43","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065973","Version":"HPD4.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:47:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"442b737a911c4ce88402c62648838ae7"}]},{"ProductId":"58058fc7c39a49caa2844dbe139ab3f9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDA"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDA"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDA"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDA"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20589253","DateModified":"2025-03-06T07:25:03","FileList":["/CP065998_BUILD_7.data","/CP065998.vmexe64","/CP065998.vmfile","/CP065998_VMw.zip","/CP065998.xml","/payload.json","/CP065998_VMw.zip/index.xml","/CP065998_VMw.zip/vendor-index.xml","/CP065998_VMw.zip/metadata.zip","/CP065998_VMw.zip/vib20/CP065998/HPE_bootbank_CP065998_HPDA.7-8.0.0.20613240.vib","/CP065998_VMw.zip/metadata.zip/vendor-index.xml","/CP065998_VMw.zip/metadata.zip/vmware.xml","/CP065998_VMw.zip/metadata.zip/vibs/CP065998--4674513720126241536.xml","/CP065998_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065998_HPDA.7-8.0.0.20613240.xml"],"MD5Sum":"371d6b8fe6639712e6902f2192e289a3","Name":"CP065998.zip","Release":"2025-03-06T07:24:17","Revision":"D","SHA1Sum":"e5a7d153cc3f3c13ab6d731bf0bc459ed27e42c1","SHA256Sum":"8efcd4f8279569b81732e6ba095f97b1c6aaebe265193afaaf4ac8d80fa8258e","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDA","VibList":[{"Name":"CP065998","Version":"HPDA.7-8.0.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG001800JWJNR、EG002400JWJNT、EG001800JXLWB、EG002400JXLWC、およびEG002400MXJQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001800JWJNR","TargetGUID":"452340a5-3047-3130-3830-304a574a4e52","Type":"sas"},{"Id":"EG002400JWJNT","TargetGUID":"452340a5-3047-3230-3430-304a574a4e54","Type":"sas"},{"Id":"EG002400MXJQT","TargetGUID":"452340a5-3047-3230-3430-304d584a5154","Type":"sas"},{"Id":"EG001800JXLWB","TargetGUID":"452340a5-3047-3130-3830-304a584c5742","Type":"sas"},{"Id":"EG002400JXLWC","TargetGUID":"452340a5-3047-3230-3430-304a584c5743","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:41:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c83fb7f18f7b47368698ae0eac6d60fe"}]},{"ProductId":"eaadba373a2b4b7ab82c00e6e1f55628","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB014000GWUDA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000GWUDA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG2</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;&nbsp; Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20905222","DateModified":"2025-03-07T06:42:53","FileList":["/CP065991_BUILD_4.data","/CP065991.vmexe64","/CP065991.vmfile","/CP065991_VMw.zip","/CP065991.xml","/payload.json","/CP065991_VMw.zip/index.xml","/CP065991_VMw.zip/vendor-index.xml","/CP065991_VMw.zip/metadata.zip","/CP065991_VMw.zip/vib20/CP065991/HPE_bootbank_CP065991_HPG3.4-1OEM.800.1.0.20613240.vib","/CP065991_VMw.zip/metadata.zip/vendor-index.xml","/CP065991_VMw.zip/metadata.zip/vmware.xml","/CP065991_VMw.zip/metadata.zip/vibs/CP065991-2927407355464872258.xml","/CP065991_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065991_HPG3.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"523e6b9a3a246bc5c4b51702bf8fbd38","Name":"CP065991.zip","Release":"2025-03-07T06:42:07","Revision":"C","SHA1Sum":"957c0d9c30f9b7f0e94ccba7109c288094185176","SHA256Sum":"99a76c613c78638bd133d5056e9a4c7a6b32cd2e2f0743d3429e6bef5d1c8abc","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065991","Version":"HPG3.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041507.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000GWUDAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000GWUDA","TargetGUID":"4d2340a5-3042-3431-3030-304757554441","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:09:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ba3b6d5b24a24394ab8fb7f685fa7394"}]},{"ProductId":"01713b1febed4cc9a463023eeb2cf6ee","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"3072104","DateModified":"2025-01-11T09:33:20","FileList":["4IYVHPG5.rel","cp065041.xml","cpqsetup.exe","payload.json","setup.dll"],"MD5Sum":"60af272a63ba209c23acae259de2fc4a","Name":"cp065041.exe","Release":"2025-01-11T09:28:42","Revision":"H","SHA1Sum":"24e6c70a8c7542fe671c96cec5dfa1741d032b7a","SHA256Sum":"51eb94ecc940614ff1e22b3c6fdc89c6e1eaa1e0f42063a03d8f3afb331b36e6","Size":"2MB","TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK001920GWJPQ","TargetGUID":"4d2340a5-304b-3130-3932-3047574a5051","Type":"sata"},{"Id":"VK001920GWJPH","TargetGUID":"562340a5-304b-3130-3932-3047574a5048","Type":"sata"},{"Id":"MK000240GWKVK","TargetGUID":"4d2340a5-304b-3030-3234-3047574b564b","Type":"sata"},{"Id":"VK000240GWJPD","TargetGUID":"562340a5-304b-3030-3234-3047574a5044","Type":"sata"},{"Id":"VK003840GWJPK","TargetGUID":"562340a5-304b-3330-3834-3047574a504b","Type":"sata"},{"Id":"MK000480GWJPN","TargetGUID":"4d2340a5-304b-3030-3438-3047574a504e","Type":"sata"},{"Id":"VK000480GWJPE","TargetGUID":"562340a5-304b-3030-3438-3047574a5045","Type":"sata"},{"Id":"MK000960GWJPP","TargetGUID":"4d2340a5-304b-3030-3936-3047574a5050","Type":"sata"},{"Id":"VK000960GWJPF","TargetGUID":"562340a5-304b-3030-3936-3047574a5046","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T10:10:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"597fc3fbe51c4388b19cf861aaccc587"}]},{"ProductId":"33474bdb31ec42199bc00637b81a4d15","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"15224848","DateModified":"2025-03-25T06:56:57","FileList":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","Config.xml","cp066432.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"MD5Sum":"6d7bc916bc78c5d9e949a2b05b7cb223","Name":"cp066432.exe","Release":"2025-03-25T06:54:14","Revision":"G","SHA1Sum":"3b8abdcfd641dff5abbd2633f6f57081509e4cd3","SHA256Sum":"4fbbe07e4019c6e17d29afd87a748d096f008a6e92ef161a4c5611dbc776082e","Size":"14MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/t D8000 /v 0130 /i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff /i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff /l D8000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D8000 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"},{"Lang":"cn","Value":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D8000 12Gb Enclosure","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"},{"Id":"D8000 12Gb IO","TargetGUID":"b99dfb74-f0bc-464f-b418-cd1857b65875","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:18:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v218471/20-D8000-Gen10RN0130_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Smart Array reporting &quot;Storage Enclosure FW upgrade Problem Detected&quot;.</li><li>PSU version is showing as &quot;No Ver&quot; after inserted the New bel power PSU.</li><li>GEM_5_2 Coverity defect fix.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v264147/20-D8000-Gen10RN0130G_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"0130"}],"SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2c4a7e04c81c4328b73f692985c83551"}]},{"ProductId":"74593c8509e24398998a42d78a910462","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33593814","DateModified":"2025-05-21T13:15:44","FileList":["A47_3.72_05_16_2025.signed.flash","A47_3.72_05_16_2025.xml","payload.json"],"MD5Sum":"f8bd42ec676cd437216d2184d1137aca","Name":"A47_3.72_05_16_2025.fwpkg","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"96cd68382d72a3f6a03f593b4e13928754ad41ea","SHA256Sum":"8460d14de3e9273bdd1e3138f0b2c7a3799e76c291804ebd17390f4bcf347ba6","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus(A47) サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"5af2d32446844d94a1c48bb40a6accc1"}]},{"ProductId":"19d0fae1d2d44133a57fe6d71c8af4b7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7349688","DateModified":"2025-05-14T06:09:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/CP066529.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066529.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066529.scexe"],"MD5Sum":"4c3cefc576cd76ec1aba8a94620fce71","Name":"firmware-hdd-a27c95663d-HPK6-4.1.x86_64.rpm","Release":"2025-05-14T10:57:05","Revision":"D","SHA1Sum":"295f22dcbbe72193f31041df2f71dc5b4c49f008","SHA256Sum":"444478cbb03b11f5d2d9854db1d8fc4c00a65e2f04a0835187220df7ac7c11ff","Size":"7MB","TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"2","Version":"HPK6"}],"Installation":{"Command":"CP041864.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"},{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:50:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li><p>This component provides support only for VMD enabled Intel VROC platform.</p></li></ul>","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"<ul><li><p>このコンポーネントは、VMD対応Intel VROCプラットフォームのサポートのみを提供します。</p></li></ul>","Fixes":"<ul><li>以前のファームウェアバージョンHPK5では、修正不可能なマシンチェック例外 (UMCE) が発生する可能性があります。ファームウェアバージョンを少なくともHPK6へアップデートすることが推奨されます。</li><li>詳しくは、CAが次のURLで公開されています。<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li><p>This component provides support only for VMD enabled Intel VROC platform.</p></li></ul>","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA is published&nbsp;at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b86880ab06934af1ae10a1cd6b78b20f"}]},{"ProductId":"35cb34a457a347fd86df4f560cf6cf57","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Linuxオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"3347576","DateModified":"2024-10-21T03:20:21","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/CP063143.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.7-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063143.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063143.scexe"],"MD5Sum":"72350112f0980b0a0a66914d99a7088f","Name":"firmware-nic-mellanox-eth-only-mft-1.0.7-1.1.x86_64.rpm","Release":"2024-10-21T08:17:36","Revision":"C","SHA1Sum":"680e758610647ec3af4b5209adf558ea0c8bd42b","SHA256Sum":"9d52928dff10d98512c1053808e28dff866539524091a64dfb0f251850b901c6","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.7"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Linux x86_64）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-05T06:39:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in component sub-version 1.0.6(C):</strong></p><ul><li>Transaction test error was&nbsp;reported while deploying the component using SPP from HPE Linux SDR.</li></ul><p><strong>The following changes have been made&nbsp;in component sub-version 1.0.6(B):</strong></p><ul><li>Product rebuilt to support FIPS&nbsp;mode enabled OS environment.</li></ul><p><strong>The following changes have been made&nbsp;in component sub-version 1.0.6(A):</strong></p><ul><li>Product rebuilt to have the new SHA 384 signature.</li></ul><p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>P11338-B21（HPE Ethernet 10Gb 2ポート548SFP+アダプター）</li></ul><p><strong>バージョン14.32.1010には、以下の新機能と変更が含まれます。</strong></p><ul><li>3つの新しいアサートフィルター（ヘルスバッファー、NVlog、FWトレース）が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ（rate_limitに接続し、そのレート制限を共有するレート制限要素）へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。PF_NUM_OF_VF_VALIDはtrueである必要があり、PF_NUM_OF_VFはゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。</li></ul>","Fixes":"<p><strong>以下の問題点がコンポーネントのサブバージョン1.0.6(C)で修正されました：</strong></p><ul><li>HPE Linux SDRからSPPを使用したコンポーネントの展開中に、トランザクションテストエラーが報告されました。</li></ul><p><strong>以下の変更がコンポーネントのサブバージョン1.0.6(B)で行われました：</strong></p><ul><li>FIPSモード対応OS環境をサポートするように製品を再構築しました。</li></ul><p><strong>以下の変更がコンポーネントのサブバージョン1.0.6(A)で行われました：</strong></p><ul><li>新しいSHA384署名を持つように再構築された製品です。</li></ul><p><strong>以下の問題点がファームウェアバージョン14.32.1010で修正されました。</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>New features and changes included in version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in component sub-version 1.0.6(C):</strong></p><ul><li>Transaction test error was&nbsp;reported while deploying the component using SPP from HPE Linux SDR.</li></ul><p><strong>The following changes have been made&nbsp;in component sub-version 1.0.6(B):</strong></p><ul><li>Product rebuilt to support FIPS&nbsp;mode enabled OS environment.</li></ul><p><strong>The following changes have been made&nbsp;in component sub-version 1.0.6(A):</strong></p><ul><li>Product rebuilt to have the new SHA 384 signature.</li></ul><p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul>","Lang":"cn"}],"Version":"1.0.6"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"cn"}],"Version":"1.0.7"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"66f62624866e416e986ba16ccdc609f8"}]},{"ProductId":"da435657efe64ff1a664870254b46a1c","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6263926","DateModified":"2025-06-16T05:29:20","FileList":["20_43_2566-MCX653105A-HDA_HPE_Ax.pldm.signed","20_43_2566-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"899da23f67a7434fac27a98111fc3b4e","Name":"20_43_2566-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:26:52","Revision":"","SHA1Sum":"4b56fe783b93b5eacc92e747a86f8e32e099a7a5","SHA256Sum":"97e8d40181d3e6e719f9dcf86542ca1d6532d78882daf3c5d12dfc16fe114464","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T05:37:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"34fc42ff9f0545c7989842ba1700df27"}]},{"ProductId":"adefe97a484140f28ccdb1e9dfb3903c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"},{"Lang":"ja","Value":"This Component Package contains the driver for HPE Intel icen Gigabit Ethernet NICs running under VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.15.4.0.</p>"}],"Files":[{"Bytes":"722480","DateModified":"2025-03-28T07:56:55","FileList":["/cp065383.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/vendor-index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/vib20/icen/INT_bootbank_icen_1.15.4.0-1OEM.800.1.0.20613240.vib","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vendor-index.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vmware.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/vibs/icen-1474514971385702191.xml","/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240_24443371.zip/metadata.zip/bulletins/Intel-icen_1.15.4.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"dc376da5beea29ad4660fb80f3aa4e5b","Name":"cp065383.zip","Release":"2025-03-28T07:56:45","Revision":"","SHA1Sum":"61b3e0b458938218b3f79c40806bbd014076448a","SHA256Sum":"c575ac51d827704558be05f50990e54139091932b4ba92ebb907d32aab58569e","Size":"705KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"icen","Version":"1.15.4.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icen Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"Intel icen Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"Intel icen Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-22T02:46:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version for VMware 9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial&nbsp;version for VMware 9.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version for VMware 9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to align DDP with the new FW version and NVM 4.71.</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Intel-icen:1.15.4.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:1.15.4.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2e806e2923d446a290f0491501b7ccac"}]},{"ProductId":"ba1b35ce71154e9e8335778f038c2885","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.&nbsp; &nbsp; &nbsp;&nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.&nbsp; &nbsp; &nbsp;&nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7190494","DateModified":"2025-05-15T10:15:01","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/CP066590.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/PCHFA2BP.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066590.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066590.scexe"],"MD5Sum":"d13a9b028f93c5fe67b860382c7a67d5","Name":"firmware-hdd-017797f12e-HPD4-5.1.x86_64.rpm","Release":"2025-05-15T15:03:05","Revision":"E","SHA1Sum":"43ca1a1a5b84b9629237265614416d17b9372d76","SHA256Sum":"145be5b0bfad78643e8ecf7201ba7ca988c1fe8d653affc38057e00851a0fc00","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T16:51:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"05b8b1096d3d4808b9d24df13c3bfa9f"}]},{"ProductId":"f7d7f54393d44f66845199e26d4e5900","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD8"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPK および EH000600JWHPH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18063362","DateModified":"2025-03-07T11:18:07","FileList":["/CP065959_BUILD_4.data","/CP065959.vmexe64","/CP065959.vmfile","/CP065959_VMw.zip","/CP065959.xml","/payload.json","/CP065959_VMw.zip/index.xml","/CP065959_VMw.zip/vendor-index.xml","/CP065959_VMw.zip/metadata.zip","/CP065959_VMw.zip/vib20/CP065959/HPE_bootbank_CP065959_HPD8.4-1OEM.800.1.0.20613240.vib","/CP065959_VMw.zip/metadata.zip/vendor-index.xml","/CP065959_VMw.zip/metadata.zip/vmware.xml","/CP065959_VMw.zip/metadata.zip/vibs/CP065959-9022332701647601859.xml","/CP065959_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065959_HPD8.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"eaed05fa134b2055bdb22a3216313ab3","Name":"CP065959.zip","Release":"2025-03-07T11:17:18","Revision":"C","SHA1Sum":"906d84f3d1f18a1c31806ee248dc8b3cc9498fcc","SHA256Sum":"3c3a5a43344dda0ac731bc3d4d24cc68b222330525a1d457298cf10d7a8ecda5","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP065959","Version":"HPD8.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042550.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a U<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p></li><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li><li><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p></li><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p></li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li><li><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>SB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a U<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p></li><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li><li><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p></li><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p></li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li><li><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>SB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000900JWHPK","TargetGUID":"452340a5-3048-3030-3930-304a5748504b","Type":"sas"},{"Id":"EH000600JWHPH","TargetGUID":"452340a5-3048-3030-3630-304a57485048","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:49:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fd33709a37f14aa89a16abbab2f77522"}]},{"ProductId":"86420e4b9b414e61bd5c2f06d883ac98","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD4"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB002000JYDNE and MB004000JYDPB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JYDNEおよびMB004000JYDPB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JYDNE and MB004000JYDPB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JYDNE and MB004000JYDPB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20608623","DateModified":"2025-03-06T12:55:48","FileList":["/CP065967_BUILD_2.data","/CP065967.vmexe64","/CP065967.vmfile","/CP065967_VMw.zip","/CP065967.xml","/payload.json","/CP065967_VMw.zip/index.xml","/CP065967_VMw.zip/vendor-index.xml","/CP065967_VMw.zip/metadata.zip","/CP065967_VMw.zip/vib20/CP065967/HPE_bootbank_CP065967_HPD4.2-1OEM.800.1.0.20613240.vib","/CP065967_VMw.zip/metadata.zip/vendor-index.xml","/CP065967_VMw.zip/metadata.zip/vmware.xml","/CP065967_VMw.zip/metadata.zip/vibs/CP065967-3089980206084389239.xml","/CP065967_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065967_HPD4.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b129f2ee138ff755e45370953d2b334f","Name":"CP065967.zip","Release":"2025-03-06T12:54:54","Revision":"B","SHA1Sum":"2d3eed565bf16a880e8bea7c00eb7de61aa3758a","SHA256Sum":"d23a25e0662dcc0b04a2601298a2667887511ba23a48f26088ccfbcc0aa74cf4","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065967","Version":"HPD4.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JYDNE and MB004000JYDPB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB002000JYDNEおよびMB004000JYDPBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JYDPB","TargetGUID":"4d2340a5-3042-3430-3030-304a59445042","Type":"sas"},{"Id":"MB002000JYDNE","TargetGUID":"4d2340a5-3042-3230-3030-304a59444e45","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:36:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。</li><li>その他のログ機能とFW機能強化を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"737efac29c31429aac77c94f3b7974df"}]},{"ProductId":"31f49e59526b43cb994f293d4205e9e6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG4"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG4"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG4"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GZYVT、MB014000GZYVU、MB016000GZYVV、MB018000GYCLL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp; &nbsp; &nbsp;</strong>HPG4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG3<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19843305","DateModified":"2025-03-07T11:21:56","FileList":["/CP065980_BUILD_2.data","/CP065980.vmexe64","/CP065980.vmfile","/CP065980_VMw.zip","/CP065980.xml","/payload.json","/CP065980_VMw.zip/index.xml","/CP065980_VMw.zip/vendor-index.xml","/CP065980_VMw.zip/metadata.zip","/CP065980_VMw.zip/vib20/CP065980/HPE_bootbank_CP065980_HPG4.2-1OEM.800.1.0.20613240.vib","/CP065980_VMw.zip/metadata.zip/vendor-index.xml","/CP065980_VMw.zip/metadata.zip/vmware.xml","/CP065980_VMw.zip/metadata.zip/vibs/CP065980-7630158784340027244.xml","/CP065980_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065980_HPG4.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f53963d7ff3eefaa7078cc019c8336bc","Name":"CP065980.zip","Release":"2025-03-07T11:21:06","Revision":"C","SHA1Sum":"38c930877b64866a43cc258d1ae8868e9e3b1f78","SHA256Sum":"65b2ebfbdf6e0b5fca353a807178805ec3e3f8a0c2c5d7564778f666c54e0911","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP065980","Version":"HPG4.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042459.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVVおよびMB018000GYCLL ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000GZYVT","TargetGUID":"4d2340a5-3042-3231-3030-30475a595654","Type":"sata"},{"Id":"MB014000GZYVU","TargetGUID":"4d2340a5-3042-3431-3030-30475a595655","Type":"sata"},{"Id":"MB016000GZYVV","TargetGUID":"4d2340a5-3042-3631-3030-30475a595656","Type":"sata"},{"Id":"MB018000GYCLL","TargetGUID":"4d2340a5-3042-3831-3030-304759434c4c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:16:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"feef26afe3244381aacf3ac21b08abbc"}]},{"ProductId":"3fa689b1e0c54064af40f5128fac0e5b","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;</strong> None</p>"}],"Files":[{"Bytes":"20143593","DateModified":"2025-03-06T08:36:35","FileList":["/CP066011_BUILD_3.data","/CP066011.vmexe64","/CP066011.vmfile","/CP066011_VMw.zip","/CP066011.xml","/payload.json","/CP066011_VMw.zip/index.xml","/CP066011_VMw.zip/vendor-index.xml","/CP066011_VMw.zip/metadata.zip","/CP066011_VMw.zip/vib20/CP066011/HPE_bootbank_CP066011_HPG2.3-1OEM.800.1.0.20613240.vib","/CP066011_VMw.zip/metadata.zip/vendor-index.xml","/CP066011_VMw.zip/metadata.zip/vmware.xml","/CP066011_VMw.zip/metadata.zip/vibs/CP066011-8229392492772987063.xml","/CP066011_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066011_HPG2.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"8151e04ea795196fc8a3b0ea5035b80d","Name":"CP066011.zip","Release":"2025-03-06T08:35:46","Revision":"J","SHA1Sum":"ada8c11567f54026cd836c09600f3687e9d1e772","SHA256Sum":"e3b82881aa3456b96ecf36ae7e520762ff223de9507990ceceeda7faaf0cd940","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2","VibList":[{"Name":"CP066011","Version":"HPG2.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041453.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: . ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: . ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:10:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6fcc9abfdf734302bb9d64b076e28505"}]},{"ProductId":"f18fb22c5eab4952b3cc28771ba83857","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li><li>Assert fixes, logging enhancements and all current firmware improvements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li><li>Assert fixes, logging enhancements and all current firmware improvements.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5895976","DateModified":"2025-05-14T08:16:20","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/CP066557.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/SHPEEVSBPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066557.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066557.scexe"],"MD5Sum":"7260a779d593d6ba492c722afee38688","Name":"firmware-hdd-4fbb6d96e5-HPG2-4.1.x86_64.rpm","Release":"2025-05-14T13:05:09","Revision":"D","SHA1Sum":"c8d94f8ca780b21fd0dfa49a019aebb5eef01ecb","SHA256Sum":"9b3a99285291ba2f8842a883b2ab6188b81feb6acd078ed7d5665d1d9fc207fd","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:44:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6256b3099da14719a16230cd666e0945"}]},{"ProductId":"de51682518bb48a2bb985003f8a8df4e","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされるHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3610およびD3710BディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3610B and D3710B Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3620336","DateModified":"2025-07-27T12:30:33","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/CP067520.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067520.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067520.scexe"],"MD5Sum":"65057611465044ef4fbbf3fbc01d0b75","Name":"firmware-d3000-6.00-8.1.x86_64.rpm","Release":"2025-07-27T17:20:50","Revision":"H","SHA1Sum":"048062e9db295881de3555429ef3e07c0d043a9c","SHA256Sum":"67bfffa33316aec2eda6560d87290b34597dd794667316acabad342168e481a0","Size":"3MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"Installation":{"Command":"setup","CommandParams":"-t D3600B -t D3610B -t D3700B -t D3710B -v 6.00 -i Reveille-Release-6.00-build-000.bin -l D3000B.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p><ul style=\"list-style-type:square\"><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D3610B/D3710B 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Linux (x64)"},{"Lang":"cn","Value":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3610B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3710B","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T06:26:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 8.7&nbsp;</p></li><li><p>Added support of Rhel 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 8.7のサポートを追加 </p></li><li><p>Rhel 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 8.7&nbsp;</p></li><li><p>Added support of Rhel 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>Code optimization to save memory repo.</p></li><li><p>TLB exception seen while doing esp reset when expander reset was in progress.</p></li><li><p>Added the psoc 8.93 binary in peripheral images, updated the reveille version numbers.</p></li><li><p>Added whole new Delta PS-pmbus code , Updated the ESP version number.</p></li></ul><p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1808229885/v271807/20-D3000B-Gen10RN600H_ED9.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"6.00"}],"SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a928806887974621a6ecdffc37ec5b38"}]},{"ProductId":"0fb6a42a8b224caba8a145e0ac696d52","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11983078","DateModified":"2025-05-14T21:04:46","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/CP067205.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/U34_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067205.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067205.scexe"],"MD5Sum":"a9da935b324dd5d18b3a9a5ccc0962c9","Name":"firmware-system-u34-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T01:56:12","Revision":"B","SHA1Sum":"dbed012ecf9c6779891d1b1290b472f6be835b68","SHA256Sum":"4980973c69276161099f71d22a82e8063d93d77ba5377426acdf26af05b0109f","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上に見られるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10（U34）サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T01:55:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c98233b3e5b5465bb61b4751f26aae30"}]},{"ProductId":"C8691","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."},{"Lang":"cn","Value":"提供支持 HPE 支持的光纤通道主机总线适配器驱动程序的其他实用程序。"},{"Lang":"ja","Value":"HPEのサポートされるファイバーチャネルホストバスアダプタードライバーのサポートに各種ユーティリティを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"30765","DateModified":"2025-04-23T09:37:40","FileList":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"MD5Sum":"fdc589b209b96cbdbe0e383e8bd61a62","Name":"fibreutils-4.2-1_rhel.x86_64.rpm","Release":"2025-04-23T09:34:58","Revision":"k","SHA1Sum":"b674009f73f4347951e92bd2a8f5fab4a815a053","SHA256Sum":"8505422ca7c2f5a6f84fdd6584cac427d4165f38b2bd0d38b4412ffcecbcaf9f","Size":"30KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"TypeOfChange":"0","Version":"4.2-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."},{"Lang":"cn","Value":"下载 fibreutils RPM。 <BR>使用 rpm-Uvh 命令以安装/升级 RPM。"},{"Lang":"ja","Value":"fibreutils RPMをダウンロードします。 <BR>RPMをインストール/アップグレードするには、rpm -Uvhコマンドを使用してください"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Red Hat Enterprise Linux (RHEL)"},{"Lang":"cn","Value":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Red Hat Enterprise Linux (RHEL)"},{"Lang":"ja","Value":"Fibreutils for HPE Storageファイバーチャネルホストバスアダプター for Linux - Red Hat Enterprise Linux (RHEL)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-23T09:23:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>このパッケージでは、Red Hat Enterprise Linux（RHEL）ディストリビューションのみがサポートされています</p><p>アダプターサポートの変更 -- 16Gbアダプターサポートの追加 (1200E、1100Q シングルおよびデュアルアダプターサポート)</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"cn"}],"Version":"4.2-1"},{"ReleaseNotes":[{"Enhancements":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>このパッケージでは、Red Hat Enterprise Linux（RHEL）ディストリビューションのみがサポートされています</p><p>アダプターサポートの変更 -- 16Gbアダプターサポートの追加 (1200E、1100Q シングルおよびデュアルアダプターサポート)</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p><p>Modified adapter support -- added 16Gb adapter support ( 1200E,1100Q single and dual adapter support )</p>","Fixes":"","Lang":"cn"}],"Version":"4.2-1"}],"SWKeys":[{"Name":"fibreutils","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"44f35ee909f34a5184b0e66a309de883"}]},{"ProductId":"e8f02987fae14861a37eb27a43adf117","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"52804776","DateModified":"2025-06-03T13:37:01","FileList":["cp064823.xml","cpqsetup.exe","cp_data.xml","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"MD5Sum":"038fd44db4072ea249af37d24aa85cb9","Name":"cp064823.exe","Release":"2025-06-26T00:00:00","Revision":"","SHA1Sum":"22156f2a9853255640e3be51c248e8430f535902","SHA256Sum":"f483eb5100fb7a532e028ade082dbd6a24e1522697127e87e670ed3910a2e2de","Size":"50MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"TypeOfChange":"1","Version":"8.12.22.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>&nbsp;</p><p><strong>NOTE: </strong>If user tries to install the same version of the build again when the build is already installed, the behavior can be erratic. Recommendation would be to un-install and install the build to make any changes to the existing installer.</p>"},{"Lang":"ja","Value":"<p>HPE MRSAの古いバージョンがシステムにインストールされている場合、\"コントロールパネル ->プログラムのアンインストール\"からアンインストールを行った後に、\"LSA\"をアンインストールしてください。</p><p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>インストールボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p><p> </p><p><strong>注記：</strong>ビルドがすでにインストールされているときに、ユーザーが同じバージョンのビルドを再度インストールしようとすると、動作が不安定になる可能性があります。既存のインストーラーに変更を加えるには、ビルドをアンインストールしてから再インストールすることをお勧めします。</p>"},{"Lang":"cn","Value":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p><p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p><p>&nbsp;</p><p><strong>NOTE: </strong>If user tries to install the same version of the build again when the build is already installed, the behavior can be erratic. Recommendation would be to un-install and install the build to make any changes to the existing installer.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for Gen10 Plus and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator for Windows 64ビット（HPE MRSA for Gen10 PlusおよびGen11コントローラー）"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for Gen10 Plus and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T04:04:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li></ul>","Fixes":"<ul><li>Fix a00146775en_us: HPE MegaRAID Storage Administrator (MRSA) Software or&nbsp;Storage Command Line Interface (StorCLI) Tools on Servers Running Microsoft&nbsp;Windows - Blue Screen of Death (BSOD) and Unexpected&nbsp; Reboot if S100i Gen10 or&nbsp;SR100i Gen10 Plus is Enabled.</li><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>リンク分離による電力節約のサポート。phy が有効か無効かを通知する新しいイベントを追加します。</li><li>物理ドライブが正常に動作しない場合、物理ドライブの種類に不明を追加します。</li><li>より良い冷却を実現するために、NVMe ドライブの温度ポーリングの頻度を増やします。<ul><li>サポート ビット「supportNvmeThermalPoll」とコントローラー プロパティ「NVMeThermalPollIntervalInSec」。</li><li>コントローラー メニューの「その他のアクション」に「NVMeThermalPollInterval の設定」が追加されました。</li></ul></li></ul>","Fixes":"<ul><li>修正 a00146775en_us: Microsoft Windows を実行しているサーバー上の HPE MegaRAID Storage Administrator (MRSA) ソフトウェアまたはストレージコマンドラインインターフェイス (StorCLI) ツール - S100i Gen10またはSR100i Gen10 Plusが有効になっていると、ブルースクリーン (BSOD) と予期しない再起動が発生します。</li><li>LSA_MONITOR が同じイベントを繰り返し出力する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li></ul>","Fixes":"<ul><li>Fix a00146775en_us: HPE MegaRAID Storage Administrator (MRSA) Software or&nbsp;Storage Command Line Interface (StorCLI) Tools on Servers Running Microsoft&nbsp;Windows - Blue Screen of Death (BSOD) and Unexpected&nbsp; Reboot if S100i Gen10 or&nbsp;SR100i Gen10 Plus is Enabled.</li><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"cn"}],"Version":"8.12.22.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li><li>Upgrade Nginx to version 1.26.</li><li>Use Microsoft Visual C++ 2015 Redistributable exclusively.<br />Note: The Microsoft Visual C++ 2010 Redistributable, if previously installed on the&nbsp;Windows OS, will not be removed automatically. If there are any security or vulnerability&nbsp;concerns, please ensure it is manually uninstalled.</li></ul>","Fixes":"<ul><li>Fix a00146775en_us: HPE MegaRAID Storage Administrator (MRSA) Software or&nbsp;Storage Command Line Interface (StorCLI) Tools on Servers Running Microsoft&nbsp;Windows - Blue Screen of Death (BSOD) and Unexpected&nbsp; Reboot if S100i Gen10 or&nbsp;SR100i Gen10 Plus is Enabled.</li><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>リンク分離による電力節約のサポート。phy が有効か無効かを通知する新しいイベントを追加します。</li><li>物理ドライブが正常に動作しない場合、物理ドライブの種類に不明を追加します。</li><li>より良い冷却を実現するために、NVMeドライブの温度ポーリングの頻度を増やします。<ul><li>サポートビット「supportNvmeThermalPoll」とコントローラープロパティ「NVMeThermalPollIntervalInSec」。</li><li>コントローラーメニューの「その他のアクション」に「NVMeThermalPollInterval の設定」が追加されました。</li></ul></li><li>Nginxをバージョン1.26へアップグレード</li><li>Microsoft Visual C++ 2015 再配布可能パッケージのみを使用してください。<br />注記: Microsoft Visual C++ 2010 再頒布可能パッケージが Windows OS に以前にインストールされている場合、自動的に削除されません。セキュリティまたは脆弱性に関する懸念がある場合は、必ず手動でアンインストールしてください。</li></ul>","Fixes":"<ul><li>修正 a00146775en_us: Microsoft Windows を実行しているサーバー上の HPE MegaRAID Storage Administrator (MRSA) ソフトウェアまたはストレージコマンドラインインターフェイス (StorCLI) ツール - S100i Gen10またはSR100i Gen10 Plusが有効になっていると、ブルースクリーン (BSOD) と予期しない再起動が発生します。</li><li>LSA_MONITOR が同じイベントを繰り返し出力する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li><li>Upgrade Nginx to version 1.26.</li><li>Use Microsoft Visual C++ 2015 Redistributable exclusively.<br />Note: The Microsoft Visual C++ 2010 Redistributable, if previously installed on the&nbsp;Windows OS, will not be removed automatically. If there are any security or vulnerability&nbsp;concerns, please ensure it is manually uninstalled.</li></ul>","Fixes":"<ul><li>Fix a00146775en_us: HPE MegaRAID Storage Administrator (MRSA) Software or&nbsp;Storage Command Line Interface (StorCLI) Tools on Servers Running Microsoft&nbsp;Windows - Blue Screen of Death (BSOD) and Unexpected&nbsp; Reboot if S100i Gen10 or&nbsp;SR100i Gen10 Plus is Enabled.</li><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"cn"}],"Version":"8.12.22.0"}],"SWKeys":[{"Name":"lsa.exe","SWKeyExpectedPath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ea9ce03e8926458692d01e4b7aafc058"}]},{"ProductId":"be8e1065c14f4a6883e7804dae8c691e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34062332","DateModified":"2025-05-21T07:45:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/A43_3.72_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/CP067150.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-3.72_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067150.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067150.scexe"],"MD5Sum":"51517a9b9217f5f9e7453948e1f4e756","Name":"firmware-system-a43-3.72_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"1756af7b2e3ff5d0cad84c02dd2d09729a93251c","SHA256Sum":"9d07552881e63ba4eae4b04785feddd0f1683920c9627251d6bebcd5f0554c8b","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"08fe6a18f06e47fd86134f67f9fc3e94"}]},{"ProductId":"3f2f70c223354bc6b59b77123faa8545","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWCPK、EH000600JWCPL、EH000300JWCPN、EH000300JXLVR、EH000600JXLVT、EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"4026952","DateModified":"2025-01-10T12:33:21","FileList":["cp065048.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTNDB.rel"],"MD5Sum":"d208f330a7cb8409db02be68bbffbec0","Name":"cp065048.exe","Release":"2025-01-10T12:28:57","Revision":"C","SHA1Sum":"6ebe5815d9e94ee2725a5521847068d543873a13","SHA256Sum":"4db0e849350f1759307f4722b25d98e0af04abfaec1c57e65e54fe15324d59a1","Size":"3MB","TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000300JWCPK、EH000600JWCPL、EH000900JWCPN、EH000300JXLVR、EH000600JXLVT、およびEH000900JXLVUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:04:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"07a2bdf1f2614bdead26a08fcae71aa8"}]},{"ProductId":"5d636f95f482471a9bd020c928d3b4af","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.2.14.1018"},{"DeviceName":"HPE_NS204i_Gen10P_Gen11_1.2.14.1018","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.2.14.1018"}]},"MinimumActiveVersion":"1.0.14.1063","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"},{"Lang":"ja","Value":"HPE Gen11 Boot Controller NS204i-u, NS204i-dおよびHPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r用のユニバーサルファームウェアPLDMファイル"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7378966","DateModified":"2025-04-10T11:07:20","FileList":["HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.HPb","HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.xml","payload.json"],"MD5Sum":"a924aebbc494b214f0ffc017d5a7116f","Name":"HPE_NS204i_Gen10p_Gen11_1.2.14.1018_D.fwpkg","Release":"2025-04-10T11:04:53","Revision":"D","SHA1Sum":"33a80ba594dfa0a5869c81fcd2feaab0cf2c39dd","SHA256Sum":"cec12ce2090949b9ecc88c2811ae22ebe7655ec246c598bf555a8672f7bf4d31","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://buy.hpe.com/tw/zh/software/infrastructure-management-software/system-server-management-software/system-server-software-management-software/restful-interface-tool/p/7630408\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://buy.hpe.com/tw/zh/software/infrastructure-management-software/system-server-management-software/system-server-software-management-software/restful-interface-tool/p/7630408\">iLO Restfulインターフェイスツール</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://buy.hpe.com/tw/zh/software/infrastructure-management-software/system-server-management-software/system-server-software-management-software/restful-interface-tool/p/7630408\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE Gen11 Boot Controller NS204i-u, NS204i-dおよびHPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r "},{"Lang":"cn","Value":"Firmware Package - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0310","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"22","Minor":"04","Name":"Ubuntu 22.04 LTS","Platform":"ubuntu2204","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T03:21:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいサーバーのサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen 12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support new Gen 12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen 12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.2.14.1018"}],"SWKeys":[{"Name":"03791590","SWKeyExpectedPath":"firmware"},{"Name":"03801590","SWKeyExpectedPath":"firmware"},{"Name":"02F61590","SWKeyExpectedPath":"firmware"},{"Name":"030E1590","SWKeyExpectedPath":"firmware"},{"Name":"030F1590","SWKeyExpectedPath":"firmware"},{"Name":"03101590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"af9c7b4012e74690936756078f1b7f4b"}]},{"ProductId":"0134d053d49b43b1add04e5a51f6ff18","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_4p71_PLDMoMCTP_80020038.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>80020038</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター</td><td>80020038</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td><td>80020038</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524762","DateModified":"2025-04-01T02:49:09","FileList":["HPE_E810_XXVDA2_SD_4p71_PLDMoMCTP_80020038.HPb","HPE_E810_XXVDA2_SD_4p71_PLDMoMCTP_80020038.xml","payload.json"],"MD5Sum":"20824e51af8532bc0254f587d480f392","Name":"HPE_E810_XXVDA2_SD_4p71_PLDMoMCTP_80020038.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"dab7ec9f9b92db7bb6c04f4468e6cb167b7f5e32","SHA256Sum":"aed0aa9364afc9027ab16e91d70e6e47261bc4199ab304032691f651a2609efa","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:37:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"9dd38770e56547dc9630942d5edd3fc0"}]},{"ProductId":"8e8fd25144334177930f2db95d492320","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4111336","DateModified":"2025-01-13T05:37:15","FileList":["cp065098.xml","cpqsetup.exe","K401HPG5.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"d8f5e9ac67bbd4add8588eb9b8d97305","Name":"cp065098.exe","Release":"2025-01-13T05:32:03","Revision":"C","SHA1Sum":"3015e30ce33887d372063693d6f11c7ba702dcdf","SHA256Sum":"f74f410bcefa6662cd84c694407acadc2d808cd8542be6a4146523bfd658e2cb","Size":"3MB","TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000480GWTHA、VK000960GWTHB、VK001920GWTHC、およびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-13T04:41:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正には、SMARTレポートのコードの改善が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"932ac9bc70af480aa380dc7f288cb322"}]},{"ProductId":"f25420df1f7142d3a5eccbf213f27251","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34221208","DateModified":"2025-05-21T13:13:47","FileList":["A47_3.72_05_16_2025.signed.flash","cp067153.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"dcf97ffe5a2fb05ab968272f68a6e4f1","Name":"cp067153.exe","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"e8cef573ab8f4c92cdae21522e213ce283e0ac09","SHA256Sum":"484c1ae9108891a537d86913e64bbe9f93883648a0a6c74b88aa352063d937e1","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"a62f840a807641dcb200be80b5454887"}]},{"ProductId":"03a1d5d1c9c84f2b9c715674a729ac00","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG8"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07abHPG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GWTFEおよびMB014000GWTFF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for RHEL10. &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for potential hangs and timeouts, tuning fixes based on field experience and maintenance logging items</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for RHEL10. &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for potential hangs and timeouts, tuning fixes based on field experience and maintenance logging items</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5163412","DateModified":"2025-05-15T10:32:53","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/CP066597.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/TAMG07abHPG8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066597.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066597.scexe"],"MD5Sum":"e7aeb4a22e798518d078c11438b5ac79","Name":"firmware-hdd-b78255e146-HPG8-6.1.x86_64.rpm","Release":"2025-05-15T15:20:05","Revision":"F","SHA1Sum":"2cfc671569191af4880cfe1c8d57d88e32e3a64a","SHA256Sum":"f3bc04408ef797ba457438a3ca7df56bbc033166afa1a2d4143ae4580c56bb45","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"CP042460.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWTFF","TargetGUID":"4d2340a5-3042-3431-3030-304757544646","Type":"sata"},{"Id":"MB012000GWTFE","TargetGUID":"4d2340a5-3042-3231-3030-304757544645","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T18:14:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB012000GWTFE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWTFF","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e9726d1c16fd4a5abf1aa6bad71d9775"}]},{"ProductId":"3fba85b34f854c9b9b5bb51030ba5e41","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20671336","DateModified":"2025-03-06T16:28:04","FileList":["/CP065983_BUILD_3.data","/CP065983.vmexe64","/CP065983.vmfile","/CP065983_VMw.zip","/CP065983.xml","/payload.json","/CP065983_VMw.zip/index.xml","/CP065983_VMw.zip/vendor-index.xml","/CP065983_VMw.zip/metadata.zip","/CP065983_VMw.zip/vib20/CP065983/HPE_bootbank_CP065983_HPD2.3-1OEM.800.1.0.20613240.vib","/CP065983_VMw.zip/metadata.zip/vendor-index.xml","/CP065983_VMw.zip/metadata.zip/vmware.xml","/CP065983_VMw.zip/metadata.zip/vibs/CP065983-8248823532782371284.xml","/CP065983_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065983_HPD2.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"7ed2ba6e8a5acbeaa1f5a0750fb46bf6","Name":"CP065983.zip","Release":"2025-03-06T16:27:16","Revision":"F","SHA1Sum":"984a5a16236880aee2169a924f0a4e29ee1e4344","SHA256Sum":"ce723400c762662d23d9cd525b93983ae90cd6803d4e5639b6ec6c588fcbb00b","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065983","Version":"HPD2.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041489.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JWKGNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:18:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"22eb5327aa084ebaa74d6463bbe06c9d"}]},{"ProductId":"912bdc2895264227ab4d6d2895102ac1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following NVME drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK3<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5981184","DateModified":"2025-01-11T00:00:16","FileList":["cp064876.xml","cpqsetup.exe","KPE80X0AHPK5.rel","payload.json","setup.dll"],"MD5Sum":"40c89eb365c00165bf155253325afc77","Name":"cp064876.exe","Release":"2025-01-10T23:56:03","Revision":"F","SHA1Sum":"a436369d1ffbd0af9f1daa173c899b72f3bcc9dc","SHA256Sum":"66697af0cd4917e01b52825c7b64674ffba40db5765e9f06db9b2d991ad90241","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T05:02:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c9ac5ee291d045c1b384fcd49ca0c585"}]},{"ProductId":"3126d8d47de5417a878b30ed83f0673f","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2022 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"},{"Lang":"ja","Value":"This driver, MegaSAS35, provides Windows 2022 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"887256","DateModified":"2025-04-25T04:58:22","FileList":["cp064819.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"01a6210b8599b7cffa2f552fa89f0cde","Name":"cp064819.exe","Release":"2025-04-25T04:56:20","Revision":"B","SHA1Sum":"b1324bffc1772cbf39908711fa515440e4696227","SHA256Sum":"f8030efaf5e3d237da504925c4ae08d2e8d33ab2121ab28fc799dcd9b5ad5fa1","Size":"866KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2022 edition"},{"Lang":"ja","Value":"MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2022 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li><li>Support new OS <a href=\"javascript:showEditorPopup('/app/Editor-Summary.aspx?11596$8#',%20'ReferenceDataItem11596',%20false,%20true);\" id=\"SummaryContent_MajorSections_Column1Contents_3_Items_0_ctl01_1_DataGrid1_1_NameLink_1\">Azure Stack HCI 23H2</a>&nbsp;.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>新しいGen12サーバーをサポートします。</li><li>新しいOS <a href=\"javascript:showEditorPopup('/app/Editor-Summary.aspx?11596$8#',%20'ReferenceDataItem11596',%20false,%20true);\" id=\"SummaryContent_MajorSections_Column1Contents_3_Items_0_ctl01_1_DataGrid1_1_NameLink_1\">Azure Stack HCI 23H2</a>をサポートします。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li><li>Support new OS <a href=\"javascript:showEditorPopup('/app/Editor-Summary.aspx?11596$8#',%20'ReferenceDataItem11596',%20false,%20true);\" id=\"SummaryContent_MajorSections_Column1Contents_3_Items_0_ctl01_1_DataGrid1_1_NameLink_1\">Azure Stack HCI 23H2</a>&nbsp;.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.730.2.0"},{"ReleaseNotes":[{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"0875ab20031a4bbc8c9ada07ca0c52fe"}]},{"ProductId":"0b5ea35199d249309413cdf1ab404c23","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_OCP3_9p53_CFGID7p2_K97342_8000F8E2.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3755.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_9p53_CFGID7p2_K97470_8000F8EE.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains utilities and firmware for the online upgrade of Intel NIC firmware running under Microsoft Windows Server 2019, Microsoft Windows Server 2022 and Windows Server 2025"},{"Lang":"ja","Value":"This component contains utilities and firmware for the online upgrade of Intel NIC firmware running under Microsoft Windows Server 2019, Microsoft Windows Server 2022 and Windows Server 2025"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"7024968","DateModified":"2025-03-28T08:33:19","FileList":["cp065267.xml","cpqsetup.exe","FW/","FW/BootIMG_ISA.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP_ISA.txt","FW/HPE_i350T4_K68277_8000123F.txt","FW/HPE_i350T4_OCP_K53978_80001234.txt","FW/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","FW/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","FW/HPE_X710DA2_9p53_CFGID7p2_K97470_8000F8EE.bin","FW/HPE_X710DA2_OCP3_9p53_CFGID7p2_K97342_8000F8E2.bin","FW/HPE_X710_DA_OCP3_EEPROM_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"6556f3946ef1da69a20992cac6a204d0","Name":"cp065267.exe","Release":"2025-03-28T08:25:07","Revision":"B","SHA1Sum":"95926274a52f5657696484db00dea715c523c48c","SHA256Sum":"9078ed9e3da60893dc3f5b55ebeb310bb2838fcb2abb105a7ceebf872fea3712","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"5.4.4.1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_usを参照してください。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4100"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-17T07:22:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"5.4.3.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"5.4.4.1"}],"SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ae3e0d5a8d104784ac0a8346ce6b11d6"}]},{"ProductId":"182450d5bced417a85db3271254808a7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9</p><p><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9</p><p><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3671848","DateModified":"2025-01-10T14:09:12","FileList":["cp065063.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SAVNGSDA.rel","setup.dll"],"MD5Sum":"aebe72cf1a90567f5415c69041b68126","Name":"cp065063.exe","Release":"2025-01-10T14:04:47","Revision":"E","SHA1Sum":"879e0b0284c81b1d6b59a8374ce468d52d1d30f3","SHA256Sum":"cde82c8ffd9001ebdce80bb116c79a98a46d9640e3c043a2244934b1e00d42b5","Size":"3MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:06:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"56db2b4037ff4a1397ea10e3733b8a0a"}]},{"ProductId":"03d55b6f216746b88ddef311b0a8c1f9","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.27"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.27"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.27"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.27"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 8.0 and vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12763136","DateModified":"2025-03-07T08:18:12","FileList":["/CP064334_BUILD_14.data","/CP064334.vmexe64","/CP064334.vmfile","/CP064334_VMw.zip","/CP064334.xml","/payload.json","/CP064334_VMw.zip/index.xml","/CP064334_VMw.zip/vendor-index.xml","/CP064334_VMw.zip/metadata.zip","/CP064334_VMw.zip/vib20/CP064334/HPE_bootbank_CP064334_1.37.0.14-1OEM.900.0.24580437.vib","/CP064334_VMw.zip/metadata.zip/vendor-index.xml","/CP064334_VMw.zip/metadata.zip/vmware.xml","/CP064334_VMw.zip/metadata.zip/vibs/CP064334-5298665747733123646.xml","/CP064334_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064334_1.37.0.14-1OEM.900.0.24580437.xml"],"MD5Sum":"e5abc6b3607593ece897452d5d098bd1","Name":"CP064334.zip","Release":"2025-03-07T08:17:32","Revision":"","SHA1Sum":"cded85e6bf9048ea23ebc47b27e172b06946b2af","SHA256Sum":"d2f9a158a9dbe67e7fda9590b853fcfd2013675b81f3a48b12f6c421bb460643","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"1.37.0","VibList":[{"Name":"CP064334","Version":"1.37.0.14-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>手動によるインストール手順：</strong></p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>ESXi 7.0ターゲットの場合：esxcli  software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li><li>ESXi 6.xターゲットの場合：esxcli software vib install -d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します：./Execute_Component -s</li></ul></li><li>Smartコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>ESXi 7.0ターゲットの場合：esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>ESXi 6.xターゲットの場合：esxcli software vib remove -n CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Manual installation instructions:</strong></p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>For ESXi 7.0 targets: esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>For ESXi 6.x targets: esxcli software vib install -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install -d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>Clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>For ESXi 7.0 targets: esxcli software component remove -n Smart-Component-CPxxxxxx</li><li>For ESXi 6.x targets: esxcli software vib remove -n CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"VMware版HPE QLogic NX2在线固件升级实用程序"},{"Lang":"ja","Value":"HPE QLogic NX2オンライン ファームウェアアップグレードユーティリティ for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"168E","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c339d","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c1930","Type":"pci","Ven":"14E4"},{"Dev":"168E","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-168e103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16A1","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a1159000ec","Type":"pci","Ven":"1077"},{"Dev":"16A4","SubDev":"00EC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-16a4159000ec","Type":"pci","Ven":"1077"},{"Dev":"16AE","SubDev":"339D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c339d","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"18D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"193A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c193a","Type":"pci","Ven":"14E4"},{"Dev":"16AE","SubDev":"1930","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ae103c1930","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T03:49:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.35.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.37.0"}],"SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bd85de99f5db486e935b9e5b89d776e7"}]},{"ProductId":"dea19449209743ffa1d2262e07eafb25","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11555003","DateModified":"2025-05-14T21:00:29","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/CP067201.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/U33_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067201.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067201.scexe"],"MD5Sum":"af8dcf220cf0efc0cf50e2a2ded67eab","Name":"firmware-system-u33-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T01:50:58","Revision":"B","SHA1Sum":"0cd9d134ca6f4c3c69cc5b242f0512d431e99e00","SHA256Sum":"5e9fb7c92b444ee93685a073e75175c04e615475a1ae5e1d7f84a8faa91aebda","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上に見られるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML110 Gen10 (U33)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T01:49:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d7d38b9567034a38b2b8bfb6ca6f16d4"}]},{"ProductId":"e0019db6f6e24588a441b6cb4e743087","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."},{"Lang":"ja","Value":"このコンポーネントは、Microchip/Microsemi PCIe Gen4スイッチのドライバーを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"565296","DateModified":"2024-03-18T16:17:21","FileList":["cp060554.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"MD5Sum":"d16982d791cc5ecc478f2f8f5485b723","Name":"cp060554.exe","Release":"2024-03-18T16:15:01","Revision":"B","SHA1Sum":"ee98da90fcaee005bb7b8d5fdd26976dcc953dcf","SHA256Sum":"5aee61d04c746f249267193e68f66304fd687950606cbcec91b2cf574a48f673","Size":"552KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<br />インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。<br />インストールボタンをクリックしてドライバーインストールを実行します。</p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2016 and Server 2019"},{"Lang":"ja","Value":"Switchtec PCIeスイッチ管理ドライバーfor Microsoft Windows Server 2016およびServer 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedDevices":[{"Dev":"4000","SubDev":"4000","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-400011f84000","Type":"pci","Ven":"11F8"},{"Dev":"4052","SubDev":"4052","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-405211f84052","Type":"pci","Ven":"11F8"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-04-18T16:03:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update version</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>アップデートバージョン</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update version</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated SBOM requirement</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0"}],"SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fb8b975529bf4ee68a06d176cb2f9251"}]},{"ProductId":"972a94402aa14188aa7633893c7137b6","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33611478","DateModified":"2025-04-18T11:48:08","FileList":["payload.json","U33_3.50_04_17_2025.signed.flash","U33_3.50_04_17_2025.xml"],"MD5Sum":"22151aedacb1742a5bac44f7e4cc3b85","Name":"U33_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"31e4924374594c86c6dff620a816be7ce7a260ff","SHA256Sum":"b8032cf2c2bbfb50b00deb4bfe7078c531bbd10a0907d2685476dc2cf2a5057b","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"b77233ce1f044d458c15b1da70368422"}]},{"ProductId":"d04d5f721c2f4e7798db0b91a4b31687","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34056796","DateModified":"2025-06-15T21:46:14","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/CP067571.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/U56_2.42_06_13_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.42_2025_06_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067571.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067571.scexe"],"MD5Sum":"9cbef4cf43e45326e910ccc7854adde3","Name":"firmware-system-u56-2.42_2025_06_13-1.1.x86_64.rpm","Release":"2025-06-16T02:37:06","Revision":"","SHA1Sum":"cac21adf28ddaac6e7c6636a1c08776048c84a96","SHA256Sum":"029837c882692c177f059f0aaec0fda5bca83edff85d5b6d34c8131e23c97358","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE DL110 Gen10 Plus Telco（U56）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:36:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"25702fda728e4e2bac1bc885d146af15"}]},{"ProductId":"c65e02b4990e43eea4fa2402b45960eb","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000GWWQUおよびMB006000GWWQT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4019424","DateModified":"2025-01-10T14:36:13","FileList":["cp065067.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNETG8.rel","setup.dll"],"MD5Sum":"bd2a0de35de7c53c00c06a91026857ca","Name":"cp065067.exe","Release":"2025-01-10T14:32:00","Revision":"C","SHA1Sum":"386582a94a2b4d2fe6037f9ce00e24b10e529419","SHA256Sum":"6220ffc8096a5e67a3ed40d0cce331dfecd43393b191fcdf88142f46afa2fc22","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWWQU","TargetGUID":"4d2340a5-3042-3830-3030-304757575155","Type":"sata"},{"Id":"MB006000GWWQT","TargetGUID":"4d2340a5-3042-3630-3030-304757575154","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:18:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG8"}],"SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"10accc483b4c4a3d8b61217e4b477008"}]},{"ProductId":"5f5babdc8edb43cda68a851809a46823","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB014000JXUCC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JXUCC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JXUCC Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5335184","DateModified":"2025-01-10T10:32:12","FileList":["cp065036.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2BP.bin","setup.dll"],"MD5Sum":"41b4d7ef4ca4ae44eca8b98d7ae1ac9f","Name":"cp065036.exe","Release":"2025-01-10T10:27:10","Revision":"C","SHA1Sum":"9d999c38617d6c04c5a221395d25040974737699","SHA256Sum":"05183d74c20ca34680e513bd09eb4f1dd99469698caff89fa88b545ccff24a9e","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JXUCC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JXUCCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB014000JXUCC","TargetGUID":"4d2340a5-3042-3431-3030-304a58554343","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:37:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"dbb6acb2d72740cab9c41198362ab988"}]},{"ProductId":"8384f9a8878649da8d668b07fb30c48e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"Lang":"ja","Value":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"34260264","DateModified":"2025-06-16T10:31:47","FileList":["cp066993.xml","cpqsetup.exe","ilo5_314.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"MD5Sum":"083f00e69d078cf124b8ea0758594e50","Name":"cp066993.exe","Release":"2025-06-16T10:30:01","Revision":"","SHA1Sum":"1bff1a2a0ef4adf3a61082239079ebd9fa41388f","SHA256Sum":"1dcf1e57df5e3903275240b87ee05e1ca02854bddfe6c62c9a4f54153382a925","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.14"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"1","Name":"Microsoft Windows 7 (64-bit) - All Editions","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows 8.1 (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-28T04:50:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"en"},{"Enhancements":"<p>公開キー認証方式によるHPE iLO SSHへのログインでSHA2アルゴリズムをサポートし、すべてのセキュリティモードに適用できます。</p>","Fixes":"<p>• ディスク障害時にHPE Gen10サーバーのヘルスLEDの点滅がHPE iLO v3.01とHPE iLO v3.02とで異なる動作を示す問題を修正しました。</p><p>• イベントサブスクリプションでmTLSが使用されている場合にRedfishイベントが正しく送信されない問題を修正しました。</p><p>• DHE-RSA暗号が<strong>弱い暗号を無効化</strong>かつ<strong>高セキュリティ</strong>モードの設定で有効になっているとHPE iLOが脆弱になる問題を修正しました。</p><p>• Zabbixモリタリングソフトウェアで監視されている場合にHPE iLO 5 v3.10が<strong>snmpwalk timeout</strong>を返す問題を修正しました。</p><p>• ユーザーのドメイン名に<strong>\\</strong>文字が含まれているとget_email_detailsが失敗する問題を修正しました。</p><p>• 一部のサーバーで証明書のインポートが失敗して<strong>SSL certificate could not be imported since the input certificate is not intended for this server</strong>エラーになる問題を修正しました。</p><p>• HPE iLO6のシステム情報のストレージタブにドライブが順序なしで表示される問題を修正しました。</p><p>• ドライブの検出で、ドライブの取り外しまたは挿入を誤って報告するIMLメッセージがトリガーされる問題を修正しました。</p><p>• HPE Apolloサーバーの電源装置の冗長化の状態に関する問題を修正しました。</p><p>• m750サーバーブレードがクリティカル状態になり、HPE iLOに接続できなくなる問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"cn"}],"Version":"3.13"},{"ReleaseNotes":[{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"en"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"ja"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"cn"}],"Version":"3.14"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"02ff1fd529ec4d30aa63cf4a687faabe"}]},{"ProductId":"094c75ee866a4b1bb6f0e035ac316695","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"Lang":"ja","Value":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"572240","DateModified":"2025-01-14T05:47:21","FileList":["cp065109.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"MD5Sum":"b006675de15b77d45ab7894b2657511c","Name":"cp065109.exe","Release":"2025-01-14T05:44:50","Revision":"G","SHA1Sum":"eecea2618e40eb9aec1b8a15cd8603a05c3c2aa6","SHA256Sum":"ec81fdbe05b16baab720b3d72f12bce9b90472074b6c70d7e3df1b08c1440a14","Size":"558KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"iLO 5チャネルインターフェイスドライバーfor Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-14T05:40:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d59712827fd54795991986d325c19e08"}]},{"ProductId":"f74d125372264713b4a9d8ebea70260d","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34232128","DateModified":"2025-05-21T12:23:19","FileList":["A42_3.72_05_16_2025.signed.flash","cp067145.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"5e3c14a616957e4af886e88574fd0aaa","Name":"cp067145.exe","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"2a580805c0b5c3dd39b60982fb04ef733bc86418","SHA256Sum":"434fb6f4eb9129e157df27baeabfb5e02331fb7ba3f78b3e678ea607ad306f90","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7458216ea96c458091f5890547228ef5"}]},{"ProductId":"a583c05eda574560bf7c625d7e1d2b1c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5145205","DateModified":"2025-05-15T10:30:34","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/CP066598.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/TTMRNSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066598.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066598.scexe"],"MD5Sum":"2c68651c142f154e7aab97d07ad563d9","Name":"firmware-hdd-46fc43ab26-HPD4-15.1.x86_64.rpm","Release":"2025-05-15T15:19:05","Revision":"O","SHA1Sum":"cb0f19f7b2b03e3fc45f51f6ad09946445cf5b6b","SHA256Sum":"abcb840667e7f2c146b44a0532815d5366ad77248a9246ee78fbbf6e394bc8a6","Size":"4MB","TargetGUIDs":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP040290.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB2000JFDSL","TargetGUID":"002340a5-4d00-3242-3030-304a4644534c","Type":"sas"},{"Id":"MB4000JFDSN","TargetGUID":"002340a5-4d00-3442-3030-304a4644534e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T18:18:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB2000JFDSL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB4000JFDSN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fa66cd533976414988d342184574426e"}]},{"ProductId":"118ba074c4b3495fbd26210e14a17511","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33609288","DateModified":"2025-04-18T13:56:50","FileList":["payload.json","U40_3.50_04_17_2025.signed.flash","U40_3.50_04_17_2025.xml"],"MD5Sum":"880351fecbb2dff5e197b36e1de47f61","Name":"U40_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"078c6074cc4b9443c1e13604b912283e21c94d67","SHA256Sum":"4b4127ab0d5bdfbaa128b5522d3dc309dfdf962d2614640dfe7b9a18f846a67e","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"ce552811bda54316bdb5d3663a9cc6eb"}]},{"ProductId":"d3f65c2e0c364f4bb543e0989cd11684","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"33421757","DateModified":"2025-05-19T17:11:35","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/0e","./usr/lib/.build-id/0e/bd4c4b664cb62e7dc9282d03bed32f8d21dff0","./usr/lib/.build-id/10","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/11","./usr/lib/.build-id/11/1a69b05a09921c5a192e21cca0c48bf35b106e","./usr/lib/.build-id/12","./usr/lib/.build-id/12/f9e56dadad7c37843a91783aeaa76a00af2116","./usr/lib/.build-id/1d","./usr/lib/.build-id/1d/2c4719e03e2344af0b1967bfc48e2b1d594528","./usr/lib/.build-id/22","./usr/lib/.build-id/22/a8e35f956a078768a0d04a77c0fe7a4fe65ca3","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/e959ff3f94f22a98293c595ec0cbdc2b288087","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/4f47e77bbdac7220b8bdc8d50f363a2b1d4b28","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/1738cf87b97e794d94d28f05a3ccf7df85f528","./usr/lib/.build-id/4d","./usr/lib/.build-id/4d/1077c0e5529b03f90b9567386fa5503c6ecfa7","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/27669655382989d3f1a70d106fc9b7841625ae","./usr/lib/.build-id/53","./usr/lib/.build-id/53/d89996f81e5f68ea2479c0f3a2e97e3a96f846","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/80586696d19216ae4a343bea557eea2bfbcee5","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/66","./usr/lib/.build-id/66/d27ea82fe9fe174827b9bd3dab15aa559fee61","./usr/lib/.build-id/68","./usr/lib/.build-id/68/ec128992f5c24c6f298e00df166fd8b3e72ac4","./usr/lib/.build-id/69","./usr/lib/.build-id/69/25cde192badd01d8ea118a77ed86a2eebb59ce","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/5dbbb7a08e4d1686f3b5aa8139d102f551206d","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/555826078d26cbae2a89c1152664137ee63429","./usr/lib/.build-id/84","./usr/lib/.build-id/84/df3768b58b482899f8566ee837c90be819cb3b","./usr/lib/.build-id/93","./usr/lib/.build-id/93/976fe37b2391623f8c3e57603ffc9170c0244f","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/eb28ebdd103ad490c58bd5de00f9d150453f9d","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/e4acecfc6a4e3eb5a8ed58d54acb5c8208e71d","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/c040f69c0e4cb8aab2d2e4968b46a1073b6d52","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/bf/cae2285690113ce2cf6aaa4924a349bc09c19e","./usr/lib/.build-id/c2","./usr/lib/.build-id/c2/ca9737be10807c27a888bb709caa7ebec890d9","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/4922566d31db8561577311b93216b27e8a9201","./usr/lib/.build-id/c5","./usr/lib/.build-id/c5/b73af3e129bcf75a1da4118f32ebdd65c20805","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/b38b376d74e96dce65639e0eea6e5aca8cedb8","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/f4b34f43623963b071d083d86c821b2ebd7a49","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/c6ef576369fbbba64a5901f82bb44b4ae71bb1","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/5237dc4feeb829bdbe80da777e5644c3598411","./usr/lib/.build-id/e4","./usr/lib/.build-id/e4/17a6ee4ff040d2a623ab2ec56bdf3ca0e2dc1c","./usr/lib/.build-id/ef","./usr/lib/.build-id/ef/41de570485822b585c879df6c6b7b951711195","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/177b75a02f891ff177fc4d8f41a8ec8b157733","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/0c812722564a00697869be5a64e8556b15f212","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/lib64/mft/tcl","./usr/lib64/mft/tcl/bin","./usr/lib64/mft/tcl/bin/tclsh8.6","./usr/lib64/mft/tcl/lib","./usr/lib64/mft/tcl/lib/tcl8.6","./usr/lib64/mft/tcl/lib/tcl8.6/init.tcl","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x225.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"88df18e4bd7855893e3925995a1e53e2","Name":"mft-4.31.0-149.rhel9u5.x86_64.rpm","Release":"2025-05-19T17:00:04","Revision":"","SHA1Sum":"57f19a2247d3dfe76e436649f522f97a7b3f53a2","SHA256Sum":"612b4e74883eb1d5375df2ce3207edec2f9e7d81c8546ea1e22fba21f1fb805c","Size":"31MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.31.0-149"},{"Bytes":"69818","DateModified":"2025-05-19T17:06:11","FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/kernel-mft-mlnx","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"MD5Sum":"85685d4a530aafaa4c1c4fdbe6ec9c78","Name":"kmod-kernel-mft-mlnx-4.31.0-1.rhel9u5.x86_64.rpm","Release":"2025-05-19T17:00:04","Revision":"","SHA1Sum":"a4b6946339727c56f12c5190ea909ff78a839184","SHA256Sum":"e3b975125d9ed39aaf811e8371cf365255b265ce4a6566aa45cbe8b617416ff8","Size":"68KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.31.0-149"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.31.0-1.rhel9u5.x86_64.rpm&nbsp;&nbsp;mft-4.31.0-149.rhel9u5.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.31.0-1.rhel9u5.x86_64.rpm&nbsp;&nbsp;mft-4.31.0-149.rhel9u5.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />To install or upgrade the driver:<br /><br />If using kernel version 5.14.0-503.11.1.el9_5.x86_64&nbsp; &nbsp;or any future errata:<br /><strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.31.0-1.rhel9u5.x86_64.rpm&nbsp;&nbsp;mft-4.31.0-149.rhel9u5.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 5 (x86_64)"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Update 5 (x86_64)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 5 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T12:31:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.30.1-8"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.31.0-149"}],"SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"98c7673e6a94492bb625f537e66eb25b"}]},{"ProductId":"8e9f61780275418686c8b0a671e012c9","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"}],"Files":[{"Bytes":"27942847","DateModified":"2025-03-06T10:52:39","FileList":["/CP065982_BUILD_3.data","/CP065982.vmexe64","/CP065982.vmfile","/CP065982_VMw.zip","/CP065982.xml","/payload.json","/CP065982_VMw.zip/index.xml","/CP065982_VMw.zip/vendor-index.xml","/CP065982_VMw.zip/metadata.zip","/CP065982_VMw.zip/vib20/CP065982/HPE_bootbank_CP065982_HPG3.3-1OEM.800.1.0.20613240.vib","/CP065982_VMw.zip/metadata.zip/vendor-index.xml","/CP065982_VMw.zip/metadata.zip/vmware.xml","/CP065982_VMw.zip/metadata.zip/vibs/CP065982--2943951110476072958.xml","/CP065982_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065982_HPG3.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4ab74db02baaf82f9e0170eea5ef19b6","Name":"CP065982.zip","Release":"2025-03-06T10:51:53","Revision":"C","SHA1Sum":"6e0434a924b6470c6165dc7f44910cc4f05617c8","SHA256Sum":"d013f91302adc0d3beabe5fc4b96820642de24884e6b03ae900570d11384b7b2","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065982","Version":"HPG3.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043256.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:17:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b140902a90e9402ca1580bc2b9bc489b"}]},{"ProductId":"ed9a4b98eb61471ab66480b22d4e9c4f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4277592","DateModified":"2025-01-10T15:17:13","FileList":["cp065053.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"MD5Sum":"d8f2dbaa325a18fe38cd92b1dfe17ccb","Name":"cp065053.exe","Release":"2025-01-10T15:12:48","Revision":"I","SHA1Sum":"ff2d2211bb1b6e9948690bc0776c3fe7031de8b9","SHA256Sum":"e4aac41db5d20a9adde5b35e15d2708a8329e313bfde322ac5eaee37fe478e9b","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:14:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3fe416b8425542d19f0e447a80d18fe1"}]},{"ProductId":"f1a885eabd844ec18e0dab540c21f1c8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD3"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD3"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD3"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4102504","DateModified":"2025-01-10T13:57:18","FileList":["cp065042.xml","cpqsetup.exe","KAPM6ALFHPD3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"6baf1a20c4919b471b58bf97b2ea2aaf","Name":"cp065042.exe","Release":"2025-01-10T13:52:42","Revision":"B","SHA1Sum":"2f90326a6aa6d66b9bc82bf50a28fb476cfca709","SHA256Sum":"f1c172ca78e466428e42e67670e93e1834ff13926d3ac05d31ca837686f28a6a","Size":"3MB","TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VO003840XZCLT","TargetGUID":"562340a5-304f-3330-3834-30585a434c54","Type":"sas"},{"Id":"MO001600XZCLV","TargetGUID":"4d2340a5-304f-3130-3630-30585a434c56","Type":"sas"},{"Id":"MO000800XZCLQ","TargetGUID":"4d2340a5-304f-3030-3830-30585a434c51","Type":"sas"},{"Id":"VO007680XZCMB","TargetGUID":"562340a5-304f-3730-3638-30585a434d42","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T10:22:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4c7d25dc2717457284e66a55be1650cd"}]},{"ProductId":"a271f679286141d98830336f93a8205f","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"},{"Lang":"cn","Value":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17617990","DateModified":"2025-03-07T07:04:30","FileList":["/CP064921_BUILD_20.data","/CP064921.vmexe","/CP064921.vmexe64","/CP064921.vmfile","/CP064921_VMw.zip","/CP064921.xml","/payload.json","/CP064921_VMw.zip/index.xml","/CP064921_VMw.zip/vendor-index.xml","/CP064921_VMw.zip/metadata.zip","/CP064921_VMw.zip/vib20/CP064921/HPE_bootbank_CP064921_0.39.20-8.0.0.20613240.vib","/CP064921_VMw.zip/metadata.zip/vendor-index.xml","/CP064921_VMw.zip/metadata.zip/vmware.xml","/CP064921_VMw.zip/metadata.zip/vibs/CP064921--2304907022570380113.xml","/CP064921_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064921_0.39.20-8.0.0.20613240.xml"],"MD5Sum":"7bdc5e75c53cd688d3921f7b6c9df2ca","Name":"CP064921.zip","Release":"2025-03-07T06:58:55","Revision":"D","SHA1Sum":"92c172204866b9e2a62622288f519b212597a482","SHA256Sum":"4d904aee167e29b93775c553b186c0eac3bdea222bb2c9f4539f7c0bb10d1502","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39","VibList":[{"Name":"CP064921","Version":"0.39.20-8.0.0.20613240"}]}],"Installation":{"Command":"CP064921.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li><li>Boot from the newly created Service Pack for ProLiant USB key</li><li>Follow Smart Update Manager steps to complete firmware update</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP</li><li>Add the component to the SPP</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run SUM</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li><li>Follow Smart Update Manager Steps and complete the firmware update</li></ul><p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;<br /><strong>To use HP Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client</li><li>Select a server or cluster in the inventory tree</li><li>Click the HP Insight Management tab</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host</li><li>Login as root. (You must be root in order to apply the update)</li><li>Place the Smart Component zip file in a temporary directory</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-06T03:54:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>SHA384でカーネル生成環境をアップデートします</li><li>OSをアップデートします</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Update build environment with Rhel9 SHA384</li><li>Update OS</li></ul>","Fixes":"","Lang":"cn"}],"Version":"0.39"}],"SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5e1fddb843d64cc082b8f2361cbbfb50"}]},{"ProductId":"3ac61ed209fd49fb908341fa7b77c3ea","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"cn","Value":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされているドライブのSmartSSD Wear Gauge情報の提供を含む、SmartアレイおよびSmartRAIDコントローラーとサポートされているデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Running SSADUCLI<br />------------------------------------------------------------------------<br />To run the command-line application:&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p><p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />&nbsp;&nbsp;<br />&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />Additional Notes<br />----------------<br />Both the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />&nbsp; (ZIP) format.</p><p>The diagnostic report output archive contains the following files:</p><p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p><p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p><p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p><p>The SmartSSD wear gauge report output archive contains the following files:</p><p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p><p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p><p>Known Issues<br />------------<br />* When installing the 32-bit version of SSADUCLI on a system that has a<br />&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />&nbsp; installation to fail.</p>"},{"Lang":"ja","Value":"<p>SSADUCLIを実行します<br />------------------------------------------------------------------------<br />コマンド-ラインアプリケーションを実行します。   <br />   コマンドプロンプトを開いて<br />      SSADUCLIがインストールされているディレクトリに移動（cd）します。  これは通常<br />         C:\\Program Files\\Smart Storage Administrator\\ssaducli\\binです。<br />   * 診断レポートを生成するには、次のコマンドを実行します。</p><p>       ssaducli -f adu-report.zip</p><p>   SmartSSD Wear gaugeレポートを生成するには、次のコマンドを実行します。</p><p>       ssaducli -ssdrpt -f ssd-report.zip<br />  <br />   \"ssaducli -help\"によって、他のオプションを見つけることができます。<br />      <br />追加の注意<br />----------------<br />診断およびSmartSSD Wear gaugeは、圧縮（ZIP）形式でレポートを<br />  生成します。</p><p>診断レポート出力アーカイブには以下のファイルが含まれています。</p><p>   * ADUReport.txt          =>テキスト形式の診断レポート<br />   * ADUReport.xml          =>XML形式の診断レポート<br />   * ADUReport.htm          =>診断レポート用HTMLビューアー<br />   * report.checksum        =>チェックサムファイル<br />   * SlotX.txt (SlotX.old) =>コントローラーのシリアル出力ログ</p><p>   注記：シリアル出力ログファイルは\"HPE Smart <br />         Array SAS/SATA Event Notification service\"がインストールされ、実行されている場合のみ利用可能です。</p><p>   ブラウザーで診断レポートを参照するには、ADUReport.htmを抽出します。ブラウザーで<br />      ADUReport.htmを開きます。</p><p>SmartSSD wear gaugeレポート出力アーカイブには以下のファイルが含まれています。</p><p>   * SmartSSDWearGaugeReport.txt  =>テキスト形式のSmartSSD wear gaugeレポート<br />   * SmartSSDWearGaugeReport.json =>JSON形式のSmartSSD wear gaugeレポート<br />   * SmartSSDWearGaugeReport.htm  =>JSON wear gaugeレポート用のHTMLビューアー</p><p>   ブラウザーでSmartSSD Wear Gaugeレポートファイルを表示するには、<br />   SmartSSDWearGaugeReport.json,SmartSSDWearGaugeReport.htmファイルを<br />   ディレクトリに抽出します。（両方のファイルが同じディレクトリに存在する必要があります。）  ブラウザーで<br />   SmartSSDWearGaugeReport.htmを開きます。</p><p>既知の問題点<br />------------<br />* 32ビットバージョンのSSADUCLIを<br />  64ビットバージョン（x64）のSSADUCLIがインストールされたシステムにインストールする場合には、最初に<br />  64ビットバージョンをアンインストールします。64ビットバージョンのアンインストールに失敗すると、32ビットのインストールに<br />  失敗する原因となります。</p>"},{"Lang":"cn","Value":"<p>Running SSADUCLI<br />------------------------------------------------------------------------<br />To run the command-line application:&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p><p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />&nbsp;&nbsp;<br />&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />Additional Notes<br />----------------<br />Both the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />&nbsp; (ZIP) format.</p><p>The diagnostic report output archive contains the following files:</p><p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p><p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p><p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p><p>The SmartSSD wear gauge report output archive contains the following files:</p><p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p><p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p><p>Known Issues<br />------------<br />* When installing the 32-bit version of SSADUCLI on a system that has a<br />&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />&nbsp; installation to fail.</p>"}],"Files":[{"Bytes":"3546248","DateModified":"2025-04-09T08:11:21","FileList":["cp066719.xml","cpqsetup.exe","genericmsi.dll","SSADU64580_X64.msi","SSADU_RELNOTES.txt"],"MD5Sum":"78d8b3c93fb1a8ee1278f67cc85ccebb","Name":"cp066719.exe","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"c6ba12192011df96e2b31fe4cba82d3cf23b72d4","SHA256Sum":"7487c7d1311117a59079492f7c0821eb80196d4fde8591ad32753dfeaf22480c","Size":"3MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p> From that drive and directory, execute the downloaded file.</p><p> Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p> From that drive and directory, execute the downloaded file.</p><p> Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:35:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Smartコンポーネントのハングの問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix smart component hang issue.</li></ul>","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssaducli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"51f1e23f43dd4659a09f930bd429a555"}]},{"ProductId":"07117e80b64248dab9811a2280fcc85e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1726000","DateModified":"2025-03-05T07:09:18","FileList":["cp063825.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"db2181148726a5ea4b02049529c356dc","Name":"cp063825.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"5516c4722fec623d7516b737e23f6fe09282f2b6","SHA256Sum":"b6502da617ed85f057b8535c4e6371c0701cec691ce6f10828f771f5e5d1b1e1","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />[インストール]ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"HPE Storage ファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:57:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d3106165864446d5a69fc36f516838b3"}]},{"ProductId":"41b0e237fef743bfa73e14fb19e3c9ff","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、HPE Broadcom NetXtreme-Eデバイスfor Windows Server 2025のドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1094400","DateModified":"2025-04-07T01:53:12","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp066624.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"e83eb1b1fd1914256d4537386cbf1a40","Name":"cp066624.exe","Release":"2025-04-07T01:39:00","Revision":"","SHA1Sum":"0c5473cfeca41bcad8902d375433ed8a6c9ed384","SHA256Sum":"32b4d64900821a46e73afb74472d15350c0a9e5e22ec4e833fa6ce95b6eb262b","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"233.0.148.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、NXEファミリデバイスの一貫したPTPクロックのレポートを強化します。</li><li>この製品は、必要なPNP IDを追加することでデバイスの互換性を強化します。</li></ul>","Fixes":"<p>この製品は、未使用のrelease.txtファイルが削除されない問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"cn"}],"Version":"232.0.155.7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.148.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"58cc68ce8a124b5fae3fb54ba53543b5"}]},{"ProductId":"29921b6ba8e14e7cbeb3829f2308a0f5","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"03.01.33.044"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f1590032e","Version":"03.01.33.044"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900381","Version":"03.01.33.044"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"03.01.33.044"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"03.01.33.044"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the HPE SR932i-p Gen10, SR416i-a Gen10 Plus and SR932i-p, SR416ie-m Gen11 Controllers."},{"Lang":"ja","Value":"ユニバーサルファームウェアPLDMファイルfor HPE SR932i-p Gen10、SR416i-a Gen10 PlusおよびSR932i-p、SR416ie-m Gen11コントローラー"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the HPE SR932i-p Gen10, SR416i-a Gen10 Plus and SR932i-p, SR416ie-m Gen11 Controllers."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12466961","DateModified":"2024-11-28T12:30:46","FileList":["HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.HPb","HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.xml","payload.json"],"MD5Sum":"b7ec363f3fe99aaf0edfab871b5e7f43","Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.33.044_A.fwpkg","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"c96c52c5a4dbf0a3147dbc7afffc7e71c20bca6e","SHA256Sum":"ed6da1ec161f02b03f2acb31109f2d5b0b772ad66487584095b8d923f0a898ed","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"TypeOfChange":"1","Version":"03.01.33.044"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">iLO Restfulインターフェイスツール</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11コントローラー"},{"Lang":"cn","Value":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T06:04:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>SR 2.9.2/SR 3.4.2 RC2</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>SR 2.9.2/SR 3.4.2 RC2</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>SR 2.9.2/SR 3.4.2 RC2</p>","Fixes":"","Lang":"cn"}],"Version":"03.01.33.044"},{"ReleaseNotes":[{"Enhancements":"<ul><li><p>PLDM Base (Type 0) commands comply with v1.2.0 of the PLDM base specification (DSP0240).&nbsp;</p></li></ul><ul><li><p>PLDM Platform Monitoring and Control (Type 2) commands comply with v1.3.0 of the PLDM Platform Monitoring and Control Specification (DSP0248).&nbsp;</p></li></ul><ul><li><p>Long-running task support for volume creation/deletion using Redfish and storage resource RDE action operations.</p></li></ul>","Fixes":"<ul><li><p>Fixed an issue where a lockup occasionally occurs when RAID 0 Predictive Spare Rebuilding (PSR) starts.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the fault LED remains lit during the rebuild process of a replaced SSD drive.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the host was unable to retrieve new configuration updates after creating a logical drive on PF drives or slow drives.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the logical volume status was incorrectly reported as OK on a secured volume if a data drive was replaced with an Otherwise Owned SED drive before reboot.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the surface scan period was not reset to default after factory reset.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the predictive failure drive did no&euro;t fail even after the Predictive Spare Rebuild (PSR) was completed.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the Controller might have a potential lockup after a JBOD power cycle.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the offline replacement of a failed drive during a spare rebuild led to the failure of the replacement drive.&nbsp;</p></li></ul><ul><li><p>Fixed a possible lockup that could occur both during a transformation with an abrupt shutdown, and on subsequent bootup.&nbsp;</p></li></ul><ul><li><p>Fixed a potential issue where a good drive could be incorrectly marked as a predictive failure drive.&nbsp;</p></li></ul><ul><li><p>Fixed a lockup issue that could occur during I/O to a degraded volume using Smart Path.&nbsp;</p></li></ul><ul><li><p>Fixed a drive firmware update failure due to incorrect handling of sense data for specific SATA drives.&nbsp;</p></li></ul><ul><li><p>Fixed a Controller boot failure when inserted in PCIe Gen 6 systems.&nbsp;</p></li></ul><ul><li><p>Fixed issues for missing active dedicated hot spare member in HII logical drive information and failed drive part of a logical drive in the HII disk utilities.&nbsp;</p></li></ul><ul><li><p>Fixed an issue which threw wrong error code, &#39;InternalError&rsquo; when creating an array on controller that is waiting on adapter password.&nbsp;</p></li></ul><ul><li><p>Fixed an issue When server is powered on with no drives connected to Enclosure. Observe incorrect controller information in iLO Storage tab &amp; Redfish&nbsp;</p></li></ul><ul><li><p>Fixed an issue that enclosures Link is missing under Storage URI in Redfish.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which drive resource does not match with Chassis for empty bay.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which incorrect severity warning of drive when sanitize erase operation is in progress.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where HealthRollup shows warning during normal state.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where CacheSummary.Status.Health shows incorrect during WriteCache degraded.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which PLDM/RDE Read sometimes take longer than 6s during array deletion.&nbsp;</p></li></ul>","Lang":"en"},{"Enhancements":"<ul><li><p>PLDMベース (タイプ 0) コマンドは、PLDM ベース仕様 (DSP0240) の v1.2.0 に準拠しています。 </p></li></ul><ul><li><p>PLDM プラットフォーム監視および制御 (タイプ 2) コマンドは、PLDMプラットフォーム監視および制御仕様 (DSP0248) のv1.3.0に準拠しています。 </p></li></ul><ul><li><p>RedfishおよびストレージリソースRDEアクション操作を使用したボリュームの作成/削除の長期実行タスクのサポート。</p></li></ul>","Fixes":"<ul><li><p>RAID 0予測スペア再構築(PSR)の開始時にロックアップが発生することがある問題を修正しました。 </p></li></ul><ul><li><p>交換したSSDドライブの再構築プロセス中に障害LEDが点灯したままになる問題を修正しました。 </p></li></ul><ul><li><p>PFドライブまたは低速ドライブ上に論理ドライブを作成した後、ホストが新しい構成のアップデートを取得できない問題を修正しました。 </p></li></ul><ul><li><p>再起動前にデータドライブがその他の所有者のSEDドライブに置き換えられた場合、セキュリティ保護されたボリュームの論理ボリューム ステータスが誤ってOKと報告される問題を修正しました。 </p></li></ul><ul><li><p>工場出荷時の状態にリセットした後、表面スキャン期間がデフォルトにリセットされない問題を修正しました。 </p></li></ul><ul><li><p>予測スペア再構築 (PSR) が完了した後でも予測障害ドライブが障害にならない問題を修正しました。 </p></li></ul><ul><li><p>JBOD電源サイクル後にコントローラーがロックアップする可能性がある問題を修正しました。 </p></li></ul><ul><li><p>スペア再構築中に故障したドライブをオフラインで交換すると、交換ドライブが故障する問題を修正しました。 </p></li></ul><ul><li><p>突然のシャットダウンを伴う変換中とその後の起動時の両方で発生する可能性のあるロックアップを修正しました。 </p></li></ul><ul><li><p>正常なドライブが誤って予測障害ドライブとしてマークされる可能性がある問題を修正しました。 </p></li></ul><ul><li><p>Smart Pathを使用して劣化したボリュームへのI/Oを実行しているときに発生する可能性があるロックアップの問題を修正しました。 </p></li></ul><ul><li><p>特定のSATAドライブで、センスデータが正しく処理されないためにドライブファームウェアのアップデートが失敗する問題を修正しました。 </p></li></ul><ul><li><p>PCIe Gen 6システムに挿入されている場合にコントローラーの起動が失敗する問題を修正しました。 </p></li></ul><ul><li><p>HII論理ドライブ情報にアクティブな専用ホットスペアメンバーが見つからない問題と、HIIディスクユーティリティの論理ドライブのドライブ部分に障害が発生する問題を修正しました。 </p></li></ul><ul><li><p>アダプターパスワードを待機しているコントローラーでアレイを作成するときに、間違ったエラー コード「InternalError」が送られる問題を修正しました。 </p></li></ul><ul><li><p>エンクロージャーにドライブが接続されていない状態でサーバーの電源がオンになった場合の問題を修正しました。iLOのストレージタブとRedfishで不正なコントローラー情報を確認 </p></li></ul><ul><li><p>RedfishのストレージURIでエンクロージャーリンクが見つからない問題を修正しました。 </p></li></ul><ul><li><p>空のベイのドライブリソースがシャーシと一致しない問題を修正しました。 </p></li></ul><ul><li><p>サニタイズ消去操作の進行中にドライブの誤った重大度の警告が表示される問題を修正しました。 </p></li></ul><ul><li><p>通常の状態でHealthRollupが警告を表示する問題を修正しました。 </p></li></ul><ul><li><p>WriteCacheが劣化しているときにCacheSummary.Status.Healthが正しく表示されない問題を修正しました。 </p></li></ul><ul><li><p>アレイの削除中にPLDM/RDE読み取りに6秒以上かかることがある問題を修正しました。 </p></li></ul>","Lang":"ja"},{"Enhancements":"<ul><li><p>PLDM Base (Type 0) commands comply with v1.2.0 of the PLDM base specification (DSP0240).&nbsp;</p></li></ul><ul><li><p>PLDM Platform Monitoring and Control (Type 2) commands comply with v1.3.0 of the PLDM Platform Monitoring and Control Specification (DSP0248).&nbsp;</p></li></ul><ul><li><p>Long-running task support for volume creation/deletion using Redfish and storage resource RDE action operations.</p></li></ul>","Fixes":"<ul><li><p>Fixed an issue where a lockup occasionally occurs when RAID 0 Predictive Spare Rebuilding (PSR) starts.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the fault LED remains lit during the rebuild process of a replaced SSD drive.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the host was unable to retrieve new configuration updates after creating a logical drive on PF drives or slow drives.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the logical volume status was incorrectly reported as OK on a secured volume if a data drive was replaced with an Otherwise Owned SED drive before reboot.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the surface scan period was not reset to default after factory reset.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the predictive failure drive did no&euro;t fail even after the Predictive Spare Rebuild (PSR) was completed.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the Controller might have a potential lockup after a JBOD power cycle.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where the offline replacement of a failed drive during a spare rebuild led to the failure of the replacement drive.&nbsp;</p></li></ul><ul><li><p>Fixed a possible lockup that could occur both during a transformation with an abrupt shutdown, and on subsequent bootup.&nbsp;</p></li></ul><ul><li><p>Fixed a potential issue where a good drive could be incorrectly marked as a predictive failure drive.&nbsp;</p></li></ul><ul><li><p>Fixed a lockup issue that could occur during I/O to a degraded volume using Smart Path.&nbsp;</p></li></ul><ul><li><p>Fixed a drive firmware update failure due to incorrect handling of sense data for specific SATA drives.&nbsp;</p></li></ul><ul><li><p>Fixed a Controller boot failure when inserted in PCIe Gen 6 systems.&nbsp;</p></li></ul><ul><li><p>Fixed issues for missing active dedicated hot spare member in HII logical drive information and failed drive part of a logical drive in the HII disk utilities.&nbsp;</p></li></ul><ul><li><p>Fixed an issue which threw wrong error code, &#39;InternalError&rsquo; when creating an array on controller that is waiting on adapter password.&nbsp;</p></li></ul><ul><li><p>Fixed an issue When server is powered on with no drives connected to Enclosure. Observe incorrect controller information in iLO Storage tab &amp; Redfish&nbsp;</p></li></ul><ul><li><p>Fixed an issue that enclosures Link is missing under Storage URI in Redfish.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which drive resource does not match with Chassis for empty bay.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which incorrect severity warning of drive when sanitize erase operation is in progress.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where HealthRollup shows warning during normal state.&nbsp;</p></li></ul><ul><li><p>Fixed an issue where CacheSummary.Status.Health shows incorrect during WriteCache degraded.&nbsp;</p></li></ul><ul><li><p>Fixed an issue in which PLDM/RDE Read sometimes take longer than 6s during array deletion.&nbsp;</p></li></ul>","Lang":"cn"}],"Version":"03.01.33.044"}],"SWKeys":[{"Name":"02DB1590","SWKeyExpectedPath":"firmware"},{"Name":"032E1590","SWKeyExpectedPath":"firmware"},{"Name":"03811590","SWKeyExpectedPath":"firmware"},{"Name":"02941590","SWKeyExpectedPath":"firmware"},{"Name":"02DC1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"1c44c6db3e5745e5b284a591fdfd7b73"}]},{"ProductId":"84f4d8cbba034646b75e0fce6c455870","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントは、Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2022およびWindows Server 2025を含みます。"},{"Lang":"cn","Value":"This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"968656","DateModified":"2025-04-17T03:46:16","FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp066647.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"cf9134e0b940e38fccf1d5a1c3478342","Name":"cp066647.exe","Release":"2025-04-17T03:31:54","Revision":"B","SHA1Sum":"7df75c659cae7e3845aa7614ee86bbe43ca4f209","SHA256Sum":"8d94e93fd20a794499d2a8a2f0e83751e0de5241cd3aa79c3b6165551b89478b","Size":"945KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"},{"Lang":"ja","Value":"<ul><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始します。</li></ul>"},{"Lang":"cn","Value":"<ul><li>Download the Smart Component to a directory on your hard drive and change to that directory.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"ja","Value":"Broadcom NX1 1Gbドライバーfor Windows Server x64 Editions"},{"Lang":"cn","Value":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T03:12:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to enable RSS code to support systems with more than 256 CPU cores.</li><li>This product enhances to support Wake-on-LAN with 1G connection.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>この製品は、RSSコードが256個を超えるCPUコアを持つシステムをサポートできるように強化されています。</li><li>この製品は、1G接続でのWake-on-LANをサポートするように強化されています。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to enable RSS code to support systems with more than 256 CPU cores.</li><li>This product enhances to support Wake-on-LAN with 1G connection.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"221.0.7.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"221.0.8.0"}],"SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d010bd6c533b4e2492e6f02b08d461f8"}]},{"ProductId":"738515ca087c45c4b01b62883007bfb8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK7825Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000H3ドライブ<br /> <br /><strong>リリースバージョンおよび/または日付：</strong><br />      MPK7825Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />      MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />      MPK7625Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの依存関係：<br />      </strong>なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題点：</strong></p><ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点：</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     </strong>なし</p>"}],"Files":[{"Bytes":"27552301","DateModified":"2025-03-06T11:41:13","FileList":["/CP065945_BUILD_4.data","/CP065945.vmexe64","/CP065945.vmfile","/CP065945_VMw.zip","/CP065945.xml","/payload.json","/CP065945_VMw.zip/index.xml","/CP065945_VMw.zip/vendor-index.xml","/CP065945_VMw.zip/metadata.zip","/CP065945_VMw.zip/vib20/CP065945/HPE_bootbank_CP065945_MPK7825Q.4-1OEM.800.1.0.20613240.vib","/CP065945_VMw.zip/metadata.zip/vendor-index.xml","/CP065945_VMw.zip/metadata.zip/vmware.xml","/CP065945_VMw.zip/metadata.zip/vibs/CP065945--2221472532043157979.xml","/CP065945_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065945_MPK7825Q.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"0d8e8a3e65724dd9473652a3c34722ef","Name":"CP065945.zip","Release":"2025-03-06T11:40:26","Revision":"B","SHA1Sum":"d92fb51d78b9ded59f920ab0ee45357ca29c9efd","SHA256Sum":"b91f0305bcd2c3fa0cdea1e70aa68460a841b82d296d27061871fb9d42f79532","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"2","Version":"MPK7825Q","VibList":[{"Name":"CP065945","Version":"MPK7825Q.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H Drive"},{"Lang":"ja","Value":"VMware ESXi用オンラインNVMe SSDフラッシュコンポーネント - MZXLR800HBHQ-000H3、MZXLR1T6HBJR-000H3、MZXLR3T2HBLS-000H3、MZXLR6T4HALA-000H3、MZXLR12THALA-000H3、MZXLR960HBHQ-000H3、MZXLR1T9HBJR-000H3、MZXLR3T8HBLS-000H3、MZXLR7T6HALA-000H3、MZXLR15THALA-000Hドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXLR12THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3132-544869b8df72","Type":"nvme"},{"Id":"MZXLR15THALA-000H3","TargetGUID":"4d2340a5-585a-524c-3135-5448e88a517e","Type":"nvme"},{"Id":"MZXLR7T6HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3754-36484bc80db1","Type":"nvme"},{"Id":"MZXLR1T6HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Type":"nvme"},{"Id":"MZXLR800HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3830-3048c3876295","Type":"nvme"},{"Id":"MZXLR3T2HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3248a4bea716","Type":"nvme"},{"Id":"MZXLR6T4HALA-000H3","TargetGUID":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Type":"nvme"},{"Id":"MZXLR1T9HBJR-000H3","TargetGUID":"4d2340a5-585a-524c-3154-3948cda93afa","Type":"nvme"},{"Id":"MZXLR3T8HBLS-000H3","TargetGUID":"4d2340a5-585a-524c-3354-3848df400867","Type":"nvme"},{"Id":"MZXLR960HBHQ-000H3","TargetGUID":"4d2340a5-585a-524c-3936-3048d2d64915","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:30:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK7825Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK7825Q"}],"SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e038dbf393b4835a98f9e12bce3c8cc"}]},{"ProductId":"dcff0c4699e341cf85f18eb94d85147c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品は、Red Hat Enterprise Linux 9下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"124501","DateModified":"2025-04-23T02:01:08","FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/tg3","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/d2","./usr/lib/.build-id/d2/6bdf087830fe7f89fb4c4713938c1d2bc0f51a","./usr/share/smartupdate/kmod-tg3/component.xml"],"MD5Sum":"84efab4b615906f2b92b5c0db9bc8709","Name":"kmod-tg3-3.139t-1.rhel9u4.x86_64.rpm","Release":"2025-04-23T01:53:21","Revision":"","SHA1Sum":"02e29eb9b6c40a910e189d40d5b02e5186f8aca0","SHA256Sum":"4bb07525d7a40def687f2fd76de45c2bdbe98a9950d00cc37eaf748302acdb18","Size":"121KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139t-1"},{"Bytes":"125381","DateModified":"2025-04-23T02:06:13","FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/tg3","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/a0909e9de40f23fcfa5f47852bc93f6cdfb6a5","./usr/share/smartupdate/kmod-tg3/component.xml"],"MD5Sum":"5b0bf907205f874ec93a5ea59348ec49","Name":"kmod-tg3-3.139t-1.rhel9u5.x86_64.rpm","Release":"2025-04-23T01:53:21","Revision":"","SHA1Sum":"257043a50a1a2f71b62123743a112e34b2a634cf","SHA256Sum":"92c748fb361d0bea80de676ab2101013ce10e45835341862b88486b62be9259f","Size":"122KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.139t-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download README for installation notes.</p>"},{"Lang":"ja","Value":"<p>インストールのノートについてREADMEをダウンロードします。</p>"},{"Lang":"cn","Value":"<p>Download README for installation notes.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T03:12:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fix issue where tg3 driver doesn&#39;t report correct tg3 driver name in dmesg.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、tg3ドライバーがdmesgで正しいtg3ドライバー名を報告しない問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fix issue where tg3 driver doesn&#39;t report correct tg3 driver name in dmesg.</p>","Lang":"cn"}],"Version":"3.139q-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"3.139t-1"}],"SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d4762f8792f7437691b4a94ca92e4b53"}]},{"ProductId":"486d4489346f4ec8a160ad4ef3c94f99","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"18063446","DateModified":"2025-03-07T11:18:50","FileList":["/CP065963_BUILD_3.data","/CP065963.vmexe64","/CP065963.vmfile","/CP065963_VMw.zip","/CP065963.xml","/payload.json","/CP065963_VMw.zip/index.xml","/CP065963_VMw.zip/vendor-index.xml","/CP065963_VMw.zip/metadata.zip","/CP065963_VMw.zip/vib20/CP065963/HPE_bootbank_CP065963_HPD8.3-1OEM.800.1.0.20613240.vib","/CP065963_VMw.zip/metadata.zip/vendor-index.xml","/CP065963_VMw.zip/metadata.zip/vmware.xml","/CP065963_VMw.zip/metadata.zip/vibs/CP065963--3310246897150425730.xml","/CP065963_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065963_HPD8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"2f960fecf0feee9cb94f85dd720674ab","Name":"CP065963.zip","Release":"2025-03-07T11:18:00","Revision":"C","SHA1Sum":"f62e8e81477a355d44b5f39ee5e1f845783d360f","SHA256Sum":"cc6ea109a3318e9611313c9361e959b03180282b29bbb1448735bb329b6ff59d","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP065963","Version":"HPD8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041673.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:14:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bf355ff43d0c4e5d9f258788f8b3e569"}]},{"ProductId":"ae8b95207bc948489c851dd62c16f373","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3996344","DateModified":"2025-01-10T12:35:14","FileList":["BCHPC17M.bin","cp065037.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"3dee21d45418ede343c657afd07b9582","Name":"cp065037.exe","Release":"2025-01-10T12:30:48","Revision":"B","SHA1Sum":"a4621abd037504f4e689dde8d4de97adfd6b915e","SHA256Sum":"1afcef8f7b1cf1498a30d5851b4aee223a81ea4027d8b41b2a5ca531ef955867","Size":"3MB","TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"2","Version":"HPD3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:38:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\" style=\"color:#467886; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a11e2bedefd24f7380ad6b2cf91d1ae3"}]},{"ProductId":"fade5b11c713406a8e9c5f691c073fe5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 9.0."},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 9.0."},{"Lang":"ja","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.18.2.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.18.2.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.18.2.0</p>"}],"Files":[{"Bytes":"214801","DateModified":"2025-02-13T02:30:15","FileList":["/cp065456.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/vendor-index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/vib20/ixgben/INT_bootbank_ixgben_1.18.2.0-1OEM.800.1.0.20613240.vib","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vibs/ixgben--2922673856012024427.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/bulletins/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"34a1689d838b9e7b7e7184fb08597a76","Name":"cp065456.zip","Release":"2025-02-13T02:29:00","Revision":"","SHA1Sum":"11fa76c8ca2f575b56369470e7390034ad3817cc","SHA256Sum":"8abac551535dc72c4a2a1dd48bf229dbe705aba88d6e566acf4a22925781ab34","Size":"209KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"ixgben","Version":"1.18.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixgben Driver for VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE Intel ixgben Driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE Intel ixgben Driver for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-03T08:16:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Init. version for VMware 9.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Init. version for VMware 9.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Init. version for VMware 9.0</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"Intel-ixgben:1.18.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.18.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"522048d661c74fd699506db4f11012b7"}]},{"ProductId":"a8ea930bfde1449ab4444eb61f65be31","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Windows Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Windowsオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet専用アダプター</strong></td><td><strong>ファームウェアバージョン</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"28327304","DateModified":"2025-01-16T08:45:51","FileList":["cp065135.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"37e2310bf6302c8d16a836d67abbf3c2","Name":"cp065135.exe","Release":"2025-01-16T08:43:41","Revision":"A","SHA1Sum":"3bd8ed5a0cd4e4a7c9cc6f5ac44b6650b398bffb","SHA256Sum":"0dc40ea633b40564e87e6d53f25b94a6f9f08d299e6cd3207077b44309728f01","Size":"27MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.0.12"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p> From that drive and directory, execute the downloaded file.</p><p> Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> [インストール]ボタンをクリックして、インストールを開始してください。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-16T04:57:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1900にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.4030にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>ファームウェアバージョン14.32.1900には、新機能や変更は含まれていません。</strong></p><p> </p><p><strong>ファームウェアバージョン16.35.4030には新機能の追加も変更もありません。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong><br /> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4030で修正されました：</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.12"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.12(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.12(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>ファームウェアバージョン14.32.1900には修正は含まれていません。</strong><br /> </p><p><strong>以下の問題点がファームウェアのバージョン16.35.4030で修正されました：</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New changes included in component version 1.0.0.12(A):</strong></p><ul><li>Added support for&nbsp;Azure Stack HCI 23H2 in the component metadata.</li></ul><p>&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.12"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"770cbad3ff784b42b93a628974b5111f"}]},{"ProductId":"01cbc1be755b4243b92be8c9339313eb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."},{"Lang":"ja","Value":"セキュアブートモードでのHPE Mellanox MFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"69313","DateModified":"2025-05-19T18:30:33","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/mst_pci.ko","./lib/modules/6.4.0-150600.21-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"MD5Sum":"1630d99890135781f08be9f2776794f9","Name":"kernel-mft-mlnx-kmp-default-4.31.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-05-19T18:23:35","Revision":"","SHA1Sum":"7bd8e5337e6f6ce8a4caa874e7cba746eb591b7f","SHA256Sum":"46aaa50db8e8801bd46a6b48e29cd52902ad00607c351ad57b07eb19f26ecaf4","Size":"67KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.31.0-149"},{"Bytes":"33426763","DateModified":"2025-05-19T18:36:26","FileList":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/0e","./usr/lib/.build-id/0e/bd4c4b664cb62e7dc9282d03bed32f8d21dff0","./usr/lib/.build-id/10","./usr/lib/.build-id/10/c7a8c5696bd094204a596bce50b1ba1fb846cb","./usr/lib/.build-id/11","./usr/lib/.build-id/11/1a69b05a09921c5a192e21cca0c48bf35b106e","./usr/lib/.build-id/12","./usr/lib/.build-id/12/f9e56dadad7c37843a91783aeaa76a00af2116","./usr/lib/.build-id/1d","./usr/lib/.build-id/1d/2c4719e03e2344af0b1967bfc48e2b1d594528","./usr/lib/.build-id/22","./usr/lib/.build-id/22/a8e35f956a078768a0d04a77c0fe7a4fe65ca3","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/e959ff3f94f22a98293c595ec0cbdc2b288087","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/4f47e77bbdac7220b8bdc8d50f363a2b1d4b28","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/1738cf87b97e794d94d28f05a3ccf7df85f528","./usr/lib/.build-id/4d","./usr/lib/.build-id/4d/1077c0e5529b03f90b9567386fa5503c6ecfa7","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/27669655382989d3f1a70d106fc9b7841625ae","./usr/lib/.build-id/53","./usr/lib/.build-id/53/d89996f81e5f68ea2479c0f3a2e97e3a96f846","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/80586696d19216ae4a343bea557eea2bfbcee5","./usr/lib/.build-id/60","./usr/lib/.build-id/60/bfe2319a1267622d58682d4f739da72567e8f8","./usr/lib/.build-id/66","./usr/lib/.build-id/66/d27ea82fe9fe174827b9bd3dab15aa559fee61","./usr/lib/.build-id/68","./usr/lib/.build-id/68/ec128992f5c24c6f298e00df166fd8b3e72ac4","./usr/lib/.build-id/69","./usr/lib/.build-id/69/25cde192badd01d8ea118a77ed86a2eebb59ce","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/5dbbb7a08e4d1686f3b5aa8139d102f551206d","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/555826078d26cbae2a89c1152664137ee63429","./usr/lib/.build-id/84","./usr/lib/.build-id/84/df3768b58b482899f8566ee837c90be819cb3b","./usr/lib/.build-id/93","./usr/lib/.build-id/93/976fe37b2391623f8c3e57603ffc9170c0244f","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/eb28ebdd103ad490c58bd5de00f9d150453f9d","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/e4acecfc6a4e3eb5a8ed58d54acb5c8208e71d","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/c040f69c0e4cb8aab2d2e4968b46a1073b6d52","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/5eec04e20f7ffc87fc5b4375658c981df3ac11","./usr/lib/.build-id/bf/cae2285690113ce2cf6aaa4924a349bc09c19e","./usr/lib/.build-id/c2","./usr/lib/.build-id/c2/ca9737be10807c27a888bb709caa7ebec890d9","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/4922566d31db8561577311b93216b27e8a9201","./usr/lib/.build-id/c5","./usr/lib/.build-id/c5/b73af3e129bcf75a1da4118f32ebdd65c20805","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/b38b376d74e96dce65639e0eea6e5aca8cedb8","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/f4b34f43623963b071d083d86c821b2ebd7a49","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/c6ef576369fbbba64a5901f82bb44b4ae71bb1","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/5237dc4feeb829bdbe80da777e5644c3598411","./usr/lib/.build-id/e4","./usr/lib/.build-id/e4/17a6ee4ff040d2a623ab2ec56bdf3ca0e2dc1c","./usr/lib/.build-id/ef","./usr/lib/.build-id/ef/41de570485822b585c879df6c6b7b951711195","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/177b75a02f891ff177fc4d8f41a8ec8b157733","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/0c812722564a00697869be5a64e8556b15f212","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/ext_libs/libcrypto.so.3","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/lib64/mft/tcl","./usr/lib64/mft/tcl/bin","./usr/lib64/mft/tcl/bin/tclsh8.6","./usr/lib64/mft/tcl/lib","./usr/lib64/mft/tcl/lib/tcl8.6","./usr/lib64/mft/tcl/lib/tcl8.6/init.tcl","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/device_info","./usr/share/mft/device_info/json","./usr/share/mft/device_info/json/0x11.json","./usr/share/mft/device_info/json/0x19.json","./usr/share/mft/device_info/json/0x1e.json","./usr/share/mft/device_info/json/0x1f5.json","./usr/share/mft/device_info/json/0x1f7.json","./usr/share/mft/device_info/json/0x1ff.json","./usr/share/mft/device_info/json/0x209.json","./usr/share/mft/device_info/json/0x20b.json","./usr/share/mft/device_info/json/0x20d.json","./usr/share/mft/device_info/json/0x20f.json","./usr/share/mft/device_info/json/0x211.json","./usr/share/mft/device_info/json/0x212.json","./usr/share/mft/device_info/json/0x214.json","./usr/share/mft/device_info/json/0x216.json","./usr/share/mft/device_info/json/0x218.json","./usr/share/mft/device_info/json/0x21c.json","./usr/share/mft/device_info/json/0x21e.json","./usr/share/mft/device_info/json/0x220.json","./usr/share/mft/device_info/json/0x225.json","./usr/share/mft/device_info/json/0x247.json","./usr/share/mft/device_info/json/0x249.json","./usr/share/mft/device_info/json/0x24b.json","./usr/share/mft/device_info/json/0x24d.json","./usr/share/mft/device_info/json/0x24e.json","./usr/share/mft/device_info/json/0x250.json","./usr/share/mft/device_info/json/0x252.json","./usr/share/mft/device_info/json/0x253.json","./usr/share/mft/device_info/json/0x254.json","./usr/share/mft/device_info/json/0x256.json","./usr/share/mft/device_info/json/0x257.json","./usr/share/mft/device_info/json/0x259.json","./usr/share/mft/device_info/json/0x25b.json","./usr/share/mft/device_info/json/0x270.json","./usr/share/mft/device_info/json/0x274.json","./usr/share/mft/device_info/json/0x278.json","./usr/share/mft/device_info/json/0x282.json","./usr/share/mft/device_info/json/0x288.json","./usr/share/mft/device_info/json/0x2900.json","./usr/share/mft/device_info/json/0x3.json","./usr/share/mft/device_info/json/0x3000.json","./usr/share/mft/device_info/json/0x6b.json","./usr/share/mft/device_info/json/0x6e.json","./usr/share/mft/device_info/json/0x6f.json","./usr/share/mft/device_info/json/0x70.json","./usr/share/mft/device_info/json/0x71.json","./usr/share/mft/device_info/json/0x72.json","./usr/share/mft/device_info/json/0x73.json","./usr/share/mft/device_info/json/0x7e.json","./usr/share/mft/device_info/json/0x7f.json","./usr/share/mft/device_info/json/0x80.json","./usr/share/mft/device_info/json/0x82.json","./usr/share/mft/device_info/json/0x84.json","./usr/share/mft/device_info/json/0xd.json","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/gpu","./usr/share/mft/prm_dbs/gpu/ext","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers","./usr/share/mft/prm_dbs/retimers/ext","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"MD5Sum":"5b33c28bbdd174d6e17673ed6daeb2cc","Name":"mft-4.31.0-149.sles15sp6.x86_64.rpm","Release":"2025-05-19T18:23:35","Revision":"","SHA1Sum":"91c724c569f7abaa5ab0d23f2e517c101ac92531","SHA256Sum":"76e9069fd2448f7867717970182b8b3e4b8e669c4b860091e04bb18674f56f51","Size":"31MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.31.0-149"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.31.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.31.0-149.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.31.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.31.0-149.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.</p><p>To install or upgrade the driver:<br /><br />If using 6.4.0-150600.21-default kernel or any future errata:</p><p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.31.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm&nbsp;mft-4.31.0-149.sles15sp6.x86_64.rpm</strong></p><p>Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"ja","Value":"SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)のセキュアブートモードでのMellanoxアダプターのファームウェアアップデート用のHPE Mellanox MFT前提条件RPM"},{"Lang":"cn","Value":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T12:31:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Fixes":"<p>セキュアブートモードでのMFT前提条件RPM for Mellanoxアダプターファームウェアアップデート。</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.30.0-139"},{"ReleaseNotes":[{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"en"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"ja"},{"Enhancements":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Fixes":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>","Lang":"cn"}],"Version":"4.31.0-149"}],"SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"404e925237794c40bbd77e8873857543"}]},{"ProductId":"2b0745f5d1b9423aa88e57ad4cdfbe00","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB002000JWFVNおよびMB004000JWFVP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3280640","DateModified":"2025-01-11T03:12:20","FileList":["cp065058.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATRsnSD4.REL"],"MD5Sum":"801c475a1354131f44b724feffecb096","Name":"cp065058.exe","Release":"2025-01-11T03:07:33","Revision":"G","SHA1Sum":"c1eeb6e1b2cbe13f916ec63dbad46bcc206136df","SHA256Sum":"db900d174720329e478b8e566800f31c0b644d37a5c93b1925e822993d8f43e7","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB002000JWFVN","TargetGUID":"4d2340a5-3042-3230-3030-304a5746564e","Type":"sas"},{"Id":"MB004000JWFVP","TargetGUID":"4d2340a5-3042-3430-3030-304a57465650","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:27:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JWFVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JWFVP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1f2a2fd82b404d3cb31676729643b96d"}]},{"ProductId":"644b370c36714c6490fce699ffce22e9","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33607426","DateModified":"2025-04-18T12:48:00","FileList":["payload.json","U37_3.50_04_17_2025.signed.flash","U37_3.50_04_17_2025.xml"],"MD5Sum":"0926d16358cd16f62590269f059a0b03","Name":"U37_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"8250930c7d08a83b4a0edc4c01cb4a435364e60d","SHA256Sum":"8c954d31e98be17006f2f4d24ee6e0eadf523a19c8fa241fde75cbd7059a3db9","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d74e675b753a490b9e4ceccdc57c7424"}]},{"ProductId":"24ef5d7f7f9443c598148daa0f16246b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1414656","DateModified":"2025-03-28T08:13:12","FileList":["cp065298.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"17fb7a8eadf1ddacc92241b92d1d0cb7","Name":"cp065298.exe","Release":"2025-03-28T07:58:32","Revision":"","SHA1Sum":"cc2a2af408a8f14a113e43279a2de7f6bf5582ec","SHA256Sum":"0db81168ff2c8019fefbe166d8ce3fc3c5d56ceee6094ec3ca72f516a4685435","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:48:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.316.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"373d0c6dcdec4a6daacd282f5ff8c003"}]},{"ProductId":"8aa4f1e30dfc4417885cea85b551314e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.14"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_314.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.14"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"}],"Files":[{"Bytes":"34081118","DateModified":"2025-06-16T05:07:55","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/CP066992.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/ilo5_314.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.14-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066992.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066992.scexe"],"MD5Sum":"f9b03a03f761760a8b99f22a653397ed","Name":"firmware-ilo5-3.14-1.1.x86_64.rpm","Release":"2025-06-16T09:55:45","Revision":"","SHA1Sum":"84c1a6214488a05b75a3c24c377990a5dd25ba0b","SHA256Sum":"c02397297cc83b62355ed1c43375af32cb149cd2986ab756e3ee35445e2ab91e","Size":"32MB","TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.14"}],"Installation":{"Command":"sh CP0XXXXX.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Below are the steps to install/upgrade Linux Smart Component rpm files</strong></p><p style=\"margin-left:40px\">Extract the rpm file using the command &lsquo;rpm2cpio &lt;filename&gt; | cpio &ndash;idmv&rsquo;<br />Navigate to /usr/lib/x86_64-linux-gnu/firmware-ilo5-ri11-1.40-1.1<br />Run the &lsquo;hpsetup&rsquo; file using the command ./hpsetup or ./hpsetup &ndash;f when updating to same version</p><p style=\"margin-left:40px\">&nbsp;</p><p><strong>To install the Linux Smart Components perform the below steps</strong></p><p style=\"margin-left:40px\">Extract the RPM file and navigate to /usr/lib/x86_64-linux-gnu.<br />To use the Set up file, navigate to firmware-ilo5-2.xx-1.1 folder and run the same.<br />To use .scexe files, navigate to hp-scexe-compat or scexe-compat folders and run the same.</p>"},{"Lang":"ja","Value":"<p><strong>Below are the steps to install/upgrade Linux Smart Component rpm files</strong></p><p style=\"margin-left:40px\">Extract the rpm file using the command &lsquo;rpm2cpio &lt;filename&gt; | cpio &ndash;idmv&rsquo;<br />Navigate to /usr/lib/x86_64-linux-gnu/firmware-ilo5-ri11-1.40-1.1<br />Run the &lsquo;hpsetup&rsquo; file using the command ./hpsetup or ./hpsetup &ndash;f when updating to same version</p><p style=\"margin-left:40px\">&nbsp;</p><p><strong>To install the Linux Smart Components perform the below steps</strong></p><p style=\"margin-left:40px\">Extract the RPM file and navigate to /usr/lib/x86_64-linux-gnu.<br />To use the Set up file, navigate to firmware-ilo5-2.xx-1.1 folder and run the same.<br />To use .scexe files, navigate to hp-scexe-compat or scexe-compat folders and run the same.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-28T04:50:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"en"},{"Enhancements":"<p>公開キー認証方式によるHPE iLO SSHへのログインでSHA2アルゴリズムをサポートし、すべてのセキュリティモードに適用できます。</p>","Fixes":"<p>• ディスク障害時にHPE Gen10サーバーのヘルスLEDの点滅がHPE iLO v3.01とHPE iLO v3.02とで異なる動作を示す問題を修正しました。</p><p>• イベントサブスクリプションでmTLSが使用されている場合にRedfishイベントが正しく送信されない問題を修正しました。</p><p>• DHE-RSA暗号が<strong>弱い暗号を無効化</strong>かつ<strong>高セキュリティ</strong>モードの設定で有効になっているとHPE iLOが脆弱になる問題を修正しました。</p><p>• Zabbixモリタリングソフトウェアで監視されている場合にHPE iLO 5 v3.10が<strong>snmpwalk timeout</strong>を返す問題を修正しました。</p><p>• ユーザーのドメイン名に<strong>\\</strong>文字が含まれているとget_email_detailsが失敗する問題を修正しました。</p><p>• 一部のサーバーで証明書のインポートが失敗して<strong>SSL certificate could not be imported since the input certificate is not intended for this server</strong>エラーになる問題を修正しました。</p><p>• HPE iLO6のシステム情報のストレージタブにドライブが順序なしで表示される問題を修正しました。</p><p>• ドライブの検出で、ドライブの取り外しまたは挿入を誤って報告するIMLメッセージがトリガーされる問題を修正しました。</p><p>• HPE Apolloサーバーの電源装置の冗長化の状態に関する問題を修正しました。</p><p>• m750サーバーブレードがクリティカル状態になり、HPE iLOに接続できなくなる問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>Support for SHA2 algorithm with public key authentication method of logging into HPE iLO SSH and is applicable to all security modes.</p>","Fixes":"<p>&bull; Fixed an issue where an HPE Gen10 Server health LED blinks displayed different behavior between HPE iLO v3.01and HPE iLO v3.02 upon a disk failure.</p><p>&bull; Fixed an issue where a Redfish event not sent properly when event subscriptions used mTLS.</p><p>&bull; Fixed an issue where DHE-RSA ciphers are enabled with <strong>Disable Weak Ciphers </strong>and in <strong>High Security </strong>mode setting making HPE iLO vulnerable.</p><p>&bull; Fixed an issue where HPE iLO 5 v3.10 returned <strong>snmpwalk timeout </strong>when monitored by Zabbix monitoring software.</p><p>&bull; Fixed an issue where the get_email_details failed if the user domain name had a <strong>\\ </strong>character.</p><p>&bull; Fixed an issue where a certificate import failed on some servers with the <strong>SSL certificate could not be imported since the input certificate is not intended for this server </strong>error.</p><p>&bull; Fixed an issue where HPE iLO6 System Information Storage tab displayed drives without any order.</p><p>&bull; Fixed an issue with the drive discovery, where an incorrect reporting of a removal or inserted drive IML message was getting triggered.</p><p>&bull; Fixed an issue with HPE Apollo server power supply redundancy state.</p><p>&bull; Fixed an issue where m750 server blades go to a critical state and does not connect to HPE iLO.</p>","Lang":"cn"}],"Version":"3.13"},{"ReleaseNotes":[{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"en"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"ja"},{"Enhancements":"<p>Initial build</p>","Fixes":"<p>Initial build</p>","Lang":"cn"}],"Version":"3.14"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ab3fc24fcf8b465592a0f5bea3984e9c"}]},{"ProductId":"fcbfe734454648628f4d8c3848d7db3e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058565255","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058565252","Version":"HPD2"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058565254","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong></p><ul><li>&nbsp;&nbsp;&nbsp;&nbsp; Added fix to address a rare case where drive health queries can trigger false drive predictive failure</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1656680","DateModified":"2025-03-13T12:33:16","FileList":["Kioxia_PM7_KAPM7ALFHPD2.HPb","Kioxia_PM7_KAPM7ALFHPD2.xml","payload.json"],"MD5Sum":"9e822dc1ace4c96b83f315edcb901c8e","Name":"Kioxia_PM7_KAPM7ALFHPD2.fwpkg","Release":"2025-03-13T12:30:26","Revision":"","SHA1Sum":"1edcd499fc0fb24819097b63b0e1e557d27dee4b","SHA256Sum":"4c58887873fd34957c30364c356397ac207398a140c7901a04570bc1ebe27044","Size":"1MB","TargetGUIDs":["4d2340a5-304f-3130-3630-305058565255","562340a5-304f-3330-3834-305058565252","562340a5-304f-3730-3638-305058565254"],"TypeOfChange":"2","Version":"HPD2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO007680PXVRT","TargetGUID":"562340a5-304f-3730-3638-305058565254","Type":"sas"},{"Id":"VO003840PXVRR","TargetGUID":"562340a5-304f-3330-3834-305058565252","Type":"sas"},{"Id":"MO001600PXVRU","TargetGUID":"4d2340a5-304f-3130-3630-305058565255","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-12T09:56:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Added fix to address a rare case where drive health queries can trigger false drive predictive failure.</li></ul>","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO001600PXVRU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXVRR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXVRT","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"44f06c437022427688a3626804fd12c6"}]},{"ProductId":"c4ff2ade728c42bfb931931df173daf9","Versions":[{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10_04.01.05.105.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.105"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8413906","DateModified":"2025-01-17T05:58:13","FileList":["payload.json","SPSGen10_04.01.05.105.signed.bin","SPSGen10_04.01.05.105.xml"],"MD5Sum":"2f88541d026e4e92cf01c6f408d237ee","Name":"SPSGen10_04.01.05.105.fwpkg","Release":"2025-01-17T05:56:04","Revision":"","SHA1Sum":"66a91ad2b521e5408dc830a62f1353d957337856","SHA256Sum":"d2c2847dd82823dc4577a006c7f786ab6e7b3a6d1b8d194d8c1f6ba8b859fbe7","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"0","Version":"04.01.05.105"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"Lang":"ja","Value":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-10T03:19:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>このバージョンのServer Platform Services (SPS)ファームウェアには、インテル製品アップデート(IPU)バージョンIPU.2023.3ガイダンスに沿ったアップデートが含まれています。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし        </p><p><strong>改善点/新しい機能：</strong></p><p>このバージョンは、IPU.2023.3ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p><p>なし        </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2023.3 guidance.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2023.3 guidance.</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"04.01.05.002"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 04.01.05.105 should be paired with System ROM 3.40 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"04.01.05.105"}],"SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"VersionId":"c7576705f5fd47e6af7e58ac0c5a4a78"}]},{"ProductId":"cd60e68416444c61a56b3c63cb2d1ca3","Versions":[{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8322149","DateModified":"2025-04-29T14:50:14","FileList":["/CP066421_BUILD_10.data","/CP066421.vmcfg","/CP066421.vmexe64","/CP066421.vmfile","/CP066421_VMw.zip","/CP066421.xml","/payload.json","/CP066421_VMw.zip/index.xml","/CP066421_VMw.zip/vendor-index.xml","/CP066421_VMw.zip/metadata.zip","/CP066421_VMw.zip/vib20/CP066421/HPE_bootbank_CP066421_5.04.10-8.0.0.20613240.vib","/CP066421_VMw.zip/metadata.zip/vendor-index.xml","/CP066421_VMw.zip/metadata.zip/vmware.xml","/CP066421_VMw.zip/metadata.zip/vibs/CP066421-4502551030930541473.xml","/CP066421_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066421_5.04.10-8.0.0.20613240.xml"],"MD5Sum":"f597b3f57262d47662c2cf5a5bd926ca","Name":"CP066421.zip","Release":"2025-04-29T14:47:53","Revision":"L","SHA1Sum":"b66b22ce02d0287780b6ada82945f89aa84a3be8","SHA256Sum":"b47004f649b1a21f52b362eacde8fcca30db154965b5ae1caaf2647c6046647d","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04","VibList":[{"Name":"CP066421","Version":"5.04.10-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"cn","Value":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"VMware (ESXi)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D3600","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Type":"sas"},{"Id":"D3610","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18142a1148","Type":"sas"},{"Id":"D3700","TargetGUID":"b99dfb74-f0bc-464f-b418-cd186af467e1","Type":"sas"},{"Id":"D3710","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T05:54:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li><p>Enabled-ClusterS2Dコマンドは、NonStopソリューションのD3610ディスクエンクロージャー内のSATAドライブ上で実行すると正常に完了するようになりました。</p></li><li><p>SASドライブのドライブケースであるスマートキャリアは、D3610/D3710ドライブエンクロージャーで認証されるようになりました。</p></li><li><p>ファンモジュールAおよびBの問題を報告するために、新しい7セグメントエラーコードE0およびE1がそれぞれ追加されました。これらの新しいコードはD3610/D3710にのみ適用され、ファームウェア5.04を実行しているときにのみ表示されます。</p></li><li><p>I/Oモジュール内のストレージエンクロージャープロセッサーに障害が発生すると、プロセッサーを確実にオンラインに戻すために、ハードリセット（電源を切ってから電源を入れる）が実行されます。</p></li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li><p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p></li><li><p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p></li><li><p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p></li><li><p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p></li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v266654/20-D3000-Gen10RN504M_ED13.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"5.04"}],"SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"bc82ae4d00c64b929dd7aba43d1870f7"}]},{"ProductId":"39fa471cea234b3883e794de990ad252","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWCBCおよびMB002000GWCBD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4251016","DateModified":"2025-01-11T13:04:20","FileList":["cp065096.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WRN620G6.rel"],"MD5Sum":"8adf4d6c53361f99a267e6500d122706","Name":"cp065096.exe","Release":"2025-01-11T12:59:26","Revision":"I","SHA1Sum":"06528d55747fd50eed2d6f05bb5590de2c8f416e","SHA256Sum":"79b947173a62c17a503751834c543e1c6fc092c95ee676b52e31172d112db021","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB001000GWCBC","TargetGUID":"4d2340a5-3042-3130-3030-304757434243","Type":"sata"},{"Id":"MB002000GWCBD","TargetGUID":"4d2340a5-3042-3230-3030-304757434244","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T12:29:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWCBC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWCBD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2ec2a66e716b4680bc754489720fd561"}]},{"ProductId":"5521a7a96ce64d8a92b5aab1a6147b6e","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-3052584b5243","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-3052584b5248","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-3052584b524b","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-3052584b5242","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3052584b5244","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3052584b5245","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO000960RXKRC、MO001920RXKRH、MO003840RXKRK、VO000960RXKRB、VO001920RXKRD、およびVO003840RXKRE"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; N/A<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; This firmware version fixes a bug with the unmap command that may cause a drive hang<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2171292","DateModified":"2025-02-19T17:28:13","FileList":["payload.json","Seagate_LangeBP_SLNGBPHPESD5.HPb","Seagate_LangeBP_SLNGBPHPESD5.xml"],"MD5Sum":"8235c474155832e9fb1dea81d4556d0d","Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","Release":"2025-02-19T17:25:35","Revision":"B","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000960RXKRC、MO001920RXKRH、MO003840RXKRK、VO000960RXKRB、VO001920RXKRD、およびVO003840RXKRE"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000960RXKRC","TargetGUID":"4d2340a5-304f-3030-3936-3052584b5243","Type":"sas"},{"Id":"MO001920RXKRH","TargetGUID":"4d2340a5-304f-3130-3932-3052584b5248","Type":"sas"},{"Id":"MO003840RXKRK","TargetGUID":"4d2340a5-304f-3330-3834-3052584b524b","Type":"sas"},{"Id":"VO000960RXKRB","TargetGUID":"562340a5-304f-3030-3936-3052584b5242","Type":"sas"},{"Id":"VO001920RXKRD","TargetGUID":"562340a5-304f-3130-3932-3052584b5244","Type":"sas"},{"Id":"VO003840RXKRE","TargetGUID":"562340a5-304f-3330-3834-3052584b5245","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T18:26:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This firmware version fixes a bug with the unmap command that may cause a drive hang</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MO000960RXKRC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXKRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXKRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXKRB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXKRD","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXKRE","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"698b806535e54899a0d8cfa4fae3990c"}]},{"ProductId":"8d0bd1ce26004a9e8191551757cba42d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5547600","DateModified":"2025-05-15T10:17:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/CP066592.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066592.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066592.scexe"],"MD5Sum":"9497044c3c03de991f2d29cbeb3857bd","Name":"firmware-hdd-24384980ec-HPD2-3.1.x86_64.rpm","Release":"2025-05-15T15:04:08","Revision":"C","SHA1Sum":"16acbbaf5dd9d638a302bba688ced1cdf68d4061","SHA256Sum":"e72c0f422d6eaa0d5ca68c11087185791950561bbe244e8ed9fbd36726b0a255","Size":"5MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"2","Version":"HPD2"}],"Installation":{"Command":"CP040307.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T17:43:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、CBが次のURLで公開されています。https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a26b0a0152b74e779ad1c5913d900e5c"}]},{"ProductId":"d287970503c042a480f1860ec2c054c7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB016000JXLBAおよびMB018000JXLAU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; Added support for RHEL 10.</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; Added support for RHEL 10.</p><p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p><ul><li>Firmware contains fix for bug that may cause drive to perform self-initiated reset in systems where maximum queue depth of 128 is exceeded.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7202857","DateModified":"2025-05-15T10:03:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/CP066544.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/PCHFA2B3.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066544.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066544.scexe"],"MD5Sum":"efbab4e3747be86a9375f2388df9f394","Name":"firmware-hdd-d550523365-HPD3-5.1.x86_64.rpm","Release":"2025-05-15T14:49:28","Revision":"E","SHA1Sum":"5de7a079358c7545ec6ba4ec050f95974a283be7","SHA256Sum":"b4d24405886aa5f082fc43b51dff883825bf329ffbe4e9b0472878cef80f0071","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040352.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB016000JXLBAおよびMB018000JXLAUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB016000JXLBA","TargetGUID":"4d2340a5-3042-3631-3030-304a584c4241","Type":"sas"},{"Id":"MB018000JXLAU","TargetGUID":"4d2340a5-3042-3831-3030-304a584c4155","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:37:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"06d8587d6a554ef98b43d02cc7b1ac3a"}]},{"ProductId":"6a808075e9fa4bc19e7d11fd17511784","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK78H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;MPK78H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; MPK76H5Q</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>"}],"Files":[{"Bytes":"27553812","DateModified":"2025-03-06T10:57:47","FileList":["/CP065984_BUILD_12.data","/CP065984.vmexe64","/CP065984.vmfile","/CP065984_VMw.zip","/CP065984.xml","/payload.json","/CP065984_VMw.zip/index.xml","/CP065984_VMw.zip/vendor-index.xml","/CP065984_VMw.zip/metadata.zip","/CP065984_VMw.zip/vib20/CP065984/HPE_bootbank_CP065984_MPK78H5Q.12-8.0.0.20613240.vib","/CP065984_VMw.zip/metadata.zip/vendor-index.xml","/CP065984_VMw.zip/metadata.zip/vmware.xml","/CP065984_VMw.zip/metadata.zip/vibs/CP065984--20902355285946957.xml","/CP065984_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065984_MPK78H5Q.12-8.0.0.20613240.xml"],"MD5Sum":"f34ec795c48ebbc148de235c8008cafc","Name":"CP065984.zip","Release":"2025-03-06T10:56:56","Revision":"B","SHA1Sum":"9c5e5cfd0f2acb32b11c0353b31920dbd38d5ed4","SHA256Sum":"06689038d987ab449f67f46f4f960d6f20e4542be2f3398e60ed044940fd49cf","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"TypeOfChange":"2","Version":"MPK78H5Q","VibList":[{"Name":"CP065984","Version":"MPK78H5Q.12-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MZXL515THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3135-54486d0092b3","Type":"nvme"},{"Id":"MZXL512THALA-000H3","TargetGUID":"4d2340a5-585a-354c-3132-544895b51a17","Type":"nvme"},{"Id":"MZXL57T6HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3754-364820f1a5c1","Type":"nvme"},{"Id":"MZXL56T4HALA-000H3","TargetGUID":"4d2340a5-585a-354c-3654-34482ab7fb8f","Type":"nvme"},{"Id":"MZXL53T8HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-38483310a47b","Type":"nvme"},{"Id":"MZXL53T2HBLS-000H3","TargetGUID":"4d2340a5-585a-354c-3354-324884d9e9f5","Type":"nvme"},{"Id":"MZXL51T6HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-36487a9b1618","Type":"nvme"},{"Id":"MZXL5800HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3830-3048d90154e8","Type":"nvme"},{"Id":"MZXL51T9HBJR-000H3","TargetGUID":"4d2340a5-585a-354c-3154-3948e450274f","Type":"nvme"},{"Id":"MZXL5960HBHQ-000H3","TargetGUID":"4d2340a5-585a-354c-3936-304894dc03d2","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:18:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>発生する可能性がある修正不可能なマシンチェック例外(UMCE)の問題を修正しました。</li><li>詳しくは、HPEカスタマーアドバイザリ： <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix for Uncorrectable Machine Check Exception (UMCE) issue which might occur.</li><li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"MPK78H5Q"}],"SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"85cbb20de5d1424bacf3b788a8ce9163"}]},{"ProductId":"6510bb61b44e4df589649e5642d32bf1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作するIntel i40ea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1243432","DateModified":"2025-03-28T09:03:14","FileList":["cp065378.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"af9e4bb42cb85b3551e25fe3cb73d674","Name":"cp065378.exe","Release":"2025-03-28T08:48:54","Revision":"","SHA1Sum":"d1e323a03929b01894d2ae3fdf1b8d19b36abd3f","SHA256Sum":"c273add43ed7a4514cd8ab49567831854308e9ce17778f6e634980b9d85a6234","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.20.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel i40ea Driver for Windows Server 2019"},{"Lang":"ja","Value":"Intel i40eaドライバーfor Windows Server 2019"},{"Lang":"cn","Value":"Intel i40ea Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0000","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-21T07:57:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Fortville 9.5のファームウェアとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Fortville 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"1.19.164.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the wording of &quot;Ndis Poll Mode&quot; and &quot;Encapsulation Overhead,&quot; including both English and other translations.</p>","Lang":"cn"}],"Version":"1.20.100.0"}],"SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"15f3852d1d8a4a50884b2c308af82ade"}]},{"ProductId":"2e589cc6a48f40eaa0870785c3351832","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11574296","DateModified":"2025-04-18T12:44:06","FileList":["cp066820.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_3.50_04_17_2025.signed.flash"],"MD5Sum":"7658dee84a898c4da33ec08a322e810e","Name":"cp066820.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"985bd268bc982c9337db8bde1f4c18faae3a442d","SHA256Sum":"9410b50b099531a309eeee577323bb8c8ad6e129414255c131f54766e65f3c3b","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p><p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul style=\"list-style-type:square\"><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p> </p><p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul style=\"list-style-type:square\"><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p>&nbsp;</p><p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul style=\"list-style-type:square\"><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230k Gen10 (U37)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fb5c5efa11324bb49502cb4dae49cd6f"}]},{"ProductId":"75d8486987f7480b8e2a0459e1d59d0e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG2"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG2"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG2"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG2"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、MB018000GYDKR"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4035544","DateModified":"2025-01-11T11:43:16","FileList":["cp065086.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPTG2.rel"],"MD5Sum":"0da8f38ca7fc501bfaab5931801a6c68","Name":"cp065086.exe","Release":"2025-01-11T11:38:17","Revision":"C","SHA1Sum":"adc3db95e4758f51169286cc86a5100b2d779bbf","SHA256Sum":"29195af84acaecfc7c18612134b7d0442674fb7833d3b791ae1618303354ffbe","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000GYDKP、MB012000GYCJL、MB014000GYCJT、MB016000GYDKQ、およびMB018000GYDKRドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000GYDKP","TargetGUID":"4d2340a5-3042-3031-3030-304759444b50","Type":"sata"},{"Id":"MB016000GYDKQ","TargetGUID":"4d2340a5-3042-3631-3030-304759444b51","Type":"sata"},{"Id":"MB018000GYDKR","TargetGUID":"4d2340a5-3042-3831-3030-304759444b52","Type":"sata"},{"Id":"MB012000GYCJL","TargetGUID":"4d2340a5-3042-3231-3030-304759434a4c","Type":"sata"},{"Id":"MB014000GYCJT","TargetGUID":"4d2340a5-3042-3431-3030-304759434a54","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:31:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"33c4414c6bcf43e7a41622875654a722"}]},{"ProductId":"d1422347af3f4f888596c242a7fdb7a6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter"},{"Lang":"cn","Value":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter"},{"Lang":"ja","Value":"このパッケージには、Linuxサーバー上でQLogicホストバスアダプターに対してHPE Storageファイバーチャネル接続を有効にするためのユーティリティとライブラリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"866842","DateModified":"2025-05-22T03:44:09","FileList":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-aarch64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"MD5Sum":"29cc82a13768f92367b7075f557d09b6","Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","Release":"2025-05-22T03:42:17","Revision":"d","SHA1Sum":"eb15ab20231199694319166c1b71486308717235","SHA256Sum":"414f519154b20b5cd50aaf83897b3c51a7b3e4240c085ca676e2906e48d691db","Size":"846KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"TypeOfChange":"1","Version":"6.0.0.1-4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p><p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack 4&nbsp;and SuSE Linux Enterprise Server 15 service pack 5&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p><p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p><p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack 4&nbsp;and SuSE Linux Enterprise Server 15 service pack 5&nbsp;has to be performed using --reinstall option</p><p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p><p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>イネーブルメントキットは、OSインストールメディアからlibHBAAPIパッケージをインストールしたターゲット環境を必要とします。</p><p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p><p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p><p>SUSE Linux Enterprise Server 12サービスパック5での同じイネーブルメントキットバージョンの書き換えは、–forceまたは--replacepkgsと--nodepsオプションを使用して実行する必要があります。</p><p>例：rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --force --nodeps</p><p>                rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --replacepkgs --nodeps</p><p> SUSE Linux Enterprise Server 15サービスパック4およびSUSE Linux Enterprise Server 15サービスパック5での同じイネーブルメントキットバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります。</p><p>例：rpm –Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-<version>.noarch.rpm --force --nodeps</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p><p> </p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルイネーブルメントキットforホストバスアダプターfor Linux"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-07T10:42:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン6.0.0.1-4にキットをアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.1-4"},{"ReleaseNotes":[{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン6.0.0.1-4にキットをアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated the kit to version 6.0.0.1-4</p>","Fixes":"","Lang":"cn"}],"Version":"6.0.0.1-4"}],"SWKeys":[{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"67d5b946167f4f989c84ac75fcb085d4"}]},{"ProductId":"6adb26c5fc564f219877ab6a448e709b","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4_OCP_4p71_NCSIwPLDMoMCTP_80020035.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80020035</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3</td><td>80020035</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28&nbsp;OCP3</td><td>80020035</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524781","DateModified":"2025-03-28T06:39:54","FileList":["HPE_E810_XXV4_OCP_4p71_NCSIwPLDMoMCTP_80020035.HPb","HPE_E810_XXV4_OCP_4p71_NCSIwPLDMoMCTP_80020035.xml","payload.json"],"MD5Sum":"5fb816cdc29868a3ca95d51837e563ed","Name":"HPE_E810_XXV4_OCP_4p71_NCSIwPLDMoMCTP_80020035.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"d0cdfff7d778d61e850bd8f68e16bab6e34b81ae","SHA256Sum":"9d4cf9ca9289e9d32c2824fbf4a279bfd8cba45eaa9bc35162ed67e228062e6b","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:38:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"1e0432b93abb448db3c8a00614e74e53"}]},{"ProductId":"ffbc55840f92498790e9569c6abb14d8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4427816","DateModified":"2025-01-11T00:37:13","FileList":["cp064859.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TACM6ALLGPK7.rel"],"MD5Sum":"589a5d95aa0bae2016dac361cb18c833","Name":"cp064859.exe","Release":"2025-01-11T00:32:31","Revision":"C","SHA1Sum":"de48a3c7db6e31650f9bbd929fcfcd49c54f8661","SHA256Sum":"57c119e5a5ecbe74a5b1d8fd9ce60d5723224aea99337f41304d6c8e027d7f72","Size":"4MB","TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK7"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul style=\"list-style-type:square\"><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul style=\"list-style-type:square\"><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul style=\"list-style-type:square\"><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:36:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1a6fceeb80a34f2e9e9988800891cb41"}]},{"ProductId":"db808d6aa2e24648bcc5e3f46d635b1a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Lights-Out Management"},{"Lang":"ja","Value":"ソフトウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"软件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration utility is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the Linux operating system without requiring a reboot of the server."},{"Lang":"ja","Value":"HPE Lights-Outオンライン設定ユーティリティは、サーバーを再起動しないでLinux オペレーティングシステムから、ProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティです。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"63634","DateModified":"2025-06-19T09:52:18","FileList":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"MD5Sum":"5421536da7b6a75438388cf81f029a20","Name":"hponcfg-6.1.0-0.x86_64.rpm","Release":"2025-06-19T09:50:27","Revision":"A","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","Size":"62KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"TypeOfChange":"0","Version":"6.1.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><p>If a previous version of the Hponcfg utility has been installed, it must be removed before this package can be installed. To remove the previous version of the package, type the following :</p><ul><li>rpm -e hponcfg</li></ul><p>To install the package with dependency check, type:</p><ul><li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li></ul><p>To install the package withour dependency check, type:</p><ul><li>rpm -ivh --nodeps hponcfg-x.x.x.x86_64.rpm</li></ul><p>After installation, the executable for hponcfg utility can be found under the directory /sbin.</p>"},{"Lang":"ja","Value":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p><p>Hponcfgユーティリティの以前のバージョンをインストールしている場合は、削除しておかないと、このパッケージをインストールできません。パッケージの以前のバージョンを削除するには、次のように入力します：</p><ul><li>rpm -e hponcfg</li></ul><p>依存関係のチェックを行ってパッケージをインストールするには、次のように入力します。</p><ul><li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li></ul><p>依存関係のチェックを行わずにパッケージをインストールするには、次のように入力します。</p><ul><li>rpm -ivh --nodeps hponcfg-x.x.x.x86_64.rpm</li></ul><p>インストール後は、/sbinディレクトリにhponcfgの実行可能ファイルが見つかります。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)"},{"Lang":"ja","Value":"HPE Lights-Outオンライン設定ユーティリティfor Linux (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Id":"5219994","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3306103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3307103c3381","Type":"pci","Ven":"103C"},{"Dev":"3308","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3308103c3381","Type":"pci","Ven":"103C"},{"Dev":"3300","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3300103c3381","Type":"pci","Ven":"103C"},{"Dev":"3301","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3301103c3381","Type":"pci","Ven":"103C"},{"Dev":"3302","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-3302103c3381","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103c"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T05:23:45","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Fixed an issue where&nbsp;hponcfg was&nbsp;failing on Linux operating system with OpenSSL 3.X</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>OpenSSL 3.Xを搭載したLinuxオペレーティングシステムでhponcfgが失敗する問題を修正しました。</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Fixed an issue where&nbsp;hponcfg was&nbsp;failing on Linux operating system with OpenSSL 3.X</p>","Lang":"cn"}],"Version":"6.1.0-0"},{"ReleaseNotes":[{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"en"},{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"ja"},{"Enhancements":"<p>to be added</p>","Fixes":"<p>to be added</p>","Lang":"cn"}],"Version":"6.1.0.0"}],"SWKeys":[{"Name":"hponcfg","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I38","Model":"HPE ProLiant BL660c Gen9 Server"},{"Family":"I32","Model":"HP ProLiant BL660c Gen8 Server"},{"Family":"A26","Model":"HP ProLiant BL465c Gen8 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"I31","Model":"HP ProLiant BL460c Gen8 Server"},{"Family":"I30","Model":"HP ProLiant BL420c Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P79","Model":"HP ProLiant DL580 Gen8 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P77","Model":"HP ProLiant DL560 Gen8 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A28","Model":"HP ProLiant DL385p Gen8 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P70","Model":"HP ProLiant DL380p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL380e Gen8 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"P71","Model":"HP ProLiant DL360p Gen8 Server"},{"Family":"P73","Model":"HP ProLiant DL360e Gen8 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"P80","Model":"HP ProLiant DL320e Gen8 v2 Server"},{"Family":"J05","Model":"HP ProLiant DL320e Gen8 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"J03","Model":"HP ProLiant DL160 Gen8 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"P72","Model":"HP ProLiant ML350p Gen8 Server"},{"Family":"J02","Model":"HP ProLiant ML350e Gen8 Server"},{"Family":"P78","Model":"HP ProLiant ML310e Gen8 v2 Server"},{"Family":"J04","Model":"HP ProLiant ML310e Gen8 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"P88","Model":"HP ProLiant ML10 Server"},{"Family":"P74","Model":"HP ProLiant SL4540 Gen8 3 Node Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL270s Gen8 SE Server"},{"Family":"P75","Model":"HP ProLiant SL250s Gen8 Server"},{"Family":"P75","Model":"HP ProLiant SL230s Gen8 Server"},{"Family":"P83","Model":"HP ProLiant SL210t Gen8 Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"P94","Model":"HP ProLiant XL220a Gen8 v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL215n Gen10 Plus"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"J06","Model":"HP ProLiant MicroServer Gen8"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"I36","Model":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"Family":"I31","Model":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"6abdf231475c435c92bb558b96dfc97b"}]},{"ProductId":"92d9bf17d9ef471e842a80e42a41ec72","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4407776","DateModified":"2025-01-10T08:54:12","FileList":["cp065016.xml","cpqsetup.exe","HVLPeAaseFG1.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"5433b2a821a91980c6b298877b181bb6","Name":"cp065016.exe","Release":"2025-01-10T08:49:32","Revision":"J","SHA1Sum":"b7f2e24368a1866cd0077cbb19dafe6e58c9735b","SHA256Sum":"da97e16cdd76aa1e7eb1072a1393d9b73c5ffcd6da44dc74b5c34983e9fba73c","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000GWRTCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T08:10:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1681cbbe4697481384554f9ea69f1896"}]},{"ProductId":"9797527c9a7541debadf0b96aae4c9b3","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAnG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-3047575a5654","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB004000GWZVT"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MB004000GWZVT"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB004000GWZVT"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1271550","DateModified":"2024-07-09T03:49:16","FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAnG3.HPb","Toshiba_MG08Air_TAMG08ADAnG3.xml"],"MD5Sum":"11a12a97fdc85c0d5728dcf69363d995","Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","Release":"2024-07-09T03:45:20","Revision":"","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","Size":"1MB","TargetGUIDs":["4d2340a5-3042-3430-3030-3047575a5654"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  MB004000GWZVT"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB004000GWZVT","TargetGUID":"4d2340a5-3042-3430-3030-3047575a5654","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T00:59:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB004000GWZVT","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"9077ed7856b1465a8395a8ce4b5e9a97"}]},{"ProductId":"110c3bd2bca349b2ba7b9fec9e58ee8d","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v20.33.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-T Adptr</td><td><p>1.60</p></td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOM Adptr</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、下記のファームウェアバージョンを含むコンボイメージv20.33.41が含まれています：</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>ブートコードバージョン</strong></td><td><strong>PXEバージョン</strong></td><td><strong>NCSIバージョン</strong></td><td><strong>UEFIバージョン</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-Tアダプター</td><td><p>1.60</p></td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3アダプター</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOMアダプター</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOMアダプター</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains combo image v20.33.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>BCM 5719 1GbE 4p BASE-T Adptr</td><td><p>1.60</p></td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T OCP3 Adptr</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5719 1GbE 4p BASE-T LOM Adptr</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table>"}],"Files":[{"Bytes":"4683652","DateModified":"2025-04-07T01:03:52","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/CP066651.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/CP066651.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/nic_fw/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/nic_fw/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/nic_fw/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/nic_fw/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.41.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066651.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066651.scexe"],"MD5Sum":"303061b0e49aa8c54d17ea4b0d7fae1d","Name":"firmware-nic-bcm-open-2.41.0-1.1.x86_64.rpm","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"e8eb3b52d908385b9466479a70a4e75211d2ea34","SHA256Sum":"3f7e500134d1ff7c7f174fd117d181ae82aaf81044240d66358df41bff800823","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"2.41.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm </em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:33:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"}],"SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"cdbbe608b00b469b9aebcbf50c83a45b"}]},{"ProductId":"ac4d46dcda694f51abe34e6378a53487","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 8.0."},{"Lang":"ja","Value":"このパッケージは、ESXi 8.0.上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"27184959","DateModified":"2024-11-04T04:02:30","FileList":["/CP063098.vmexe64","/CP063098.vmfile","/CP063098.xml","/CP063098_VMw.zip","/payload.json","/README.txt","/CP063098_VMw.zip/index.xml","/CP063098_VMw.zip/vendor-index.xml","/CP063098_VMw.zip/metadata.zip","/CP063098_VMw.zip/vib20/CP063098/HPE_bootbank_CP063098_1.0.2-8.0.0.20613240.vib","/CP063098_VMw.zip/metadata.zip/vendor-index.xml","/CP063098_VMw.zip/metadata.zip/vmware.xml","/CP063098_VMw.zip/metadata.zip/vibs/CP063098--1262861673409423008.xml","/CP063098_VMw.zip/metadata.zip/bulletins/Smart-Component-CP063098_1.0.2-8.0.0.20613240.xml"],"MD5Sum":"6a097cee34d246dd2103f150b7068e36","Name":"CP063098.zip","Release":"2024-11-04T04:03:24","Revision":"","SHA1Sum":"20c004fd48e95ed44690dd507faa7c844d911b30","SHA256Sum":"1685f36601ffa72386e7a2544bffb09ed84aaef3cc5738757269136087a79488","Size":"25MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.5","VibList":[{"Name":"CP063098","Version":"1.0.2-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>オフライン：    </strong><br />    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p><p> </p><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />    適切なSPPをダウンロードします<br />    SPPにコンポーネントを追加します。   <br />    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />    SUMを実行します<br />    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p> </p><p><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  </strong><br />    vSphereクライアントにログインします。    <br />    インベントリツリーのサーバーまたはクラスターを選択します。 <br />    HPE Insight Managementタブをクリックします    <br />    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </p><p style=\"margin-left:40px\">ESXiホストでSSHを有効にします。<br />rootとしてログインします。（アップデートを適用するにはrootユーザーとしてログインする必要があります） <br />Smartコンポーネントを一時ディレクトリに置きます（例：/tmp/）<br />次のコマンドを使用して、nmstモジュールがすでにロードされているかどうかチェックします：vmkload_mod -l | grep nmst<br />モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします：vmkload_mod nmst<br /><br />コンポーネントを解凍します。</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">同じディレクトリから、vmexe64ファイルを実行して、レガシーSmartコンポーネントを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">または</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">以下の手順に従って、署名されたVIBを使用してファームウェアをアップデートします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">注記：署名チェックをスキップする必要がある場合は--no-sig-checkを追加します。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\"># コマンド\"./Execute_Component -s -f\"を実行して、ファームウェアをアップデートします<br /> </p><p style=\"margin-left:80px\">Smartコンポーネントの指示に従います。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ログアウトします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">ESXiホストでSSHを無効にします。</p><p style=\"margin-left:80px\"> </p><p style=\"margin-left:80px\">必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(ESXi 8.0) for HPE Mellanox Ethernetアダプター専用"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-02T11:33:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.3502:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.3502にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>ファームウェアバージョン14.32.1010には新機能の追加も変更もありません。</strong></p><ul><li>3つの新しいアサートフィルター(ヘルスバッファー、NVlog、FWトレース)が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ(rate_limitに接続し、そのレート制限を共有するレート制限要素)へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。有効にするには、PF_NUM_OF_VF_VALIDをtrueにし、PF_NUM_OF_VFをゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。                                                                                                                     </li></ul><p><strong>ファームウェアバージョン16.35.3502には新機能の追加も変更もありません。</strong></p><ul><li>TCP IPv4フローを変更し、ステアリングTIR rx_hash_symmetricフィールドが、SRCフィールドとDST フィールドの両方がゼロに設定されていない場合にのみ有効になるようになりました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアバージョン14.32.1010で修正されました。</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。</li></ul><p><strong>ファームウェアバージョン16.35.3502には修正が含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.3502:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"cn"}],"Version":"1.0.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.5"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"365827e1ff614a1cb13289323f593ff4"}]},{"ProductId":"83fed5e4a427414fb0792283dd57ec37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"800041","DateModified":"2025-06-03T11:14:28","FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"MD5Sum":"eeb61924a41cad3c603f37d0d7559255","Name":"elx-lpfc-kmp-default-14.4.473.26_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","Release":"2025-06-03T11:10:10","Revision":"","SHA1Sum":"bdc8554467f5abec909ca9e9039677ca38ecafc2","SHA256Sum":"0d47e44cc556d38f388265b6d5212ce8e09b20cfa7a20a0d7dcbab7def3b8d3b","Size":"781KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.473.26"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"ja","Value":"<p>1. システム管理者（root）としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br /><br />                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br /><br />                    例：# rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p><p><strong>重要：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br /><br />                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p><p>同じドライバーバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります</p><p>例：rpm –Uvh elx-lpfc-kmp-default-<version>.<OSupdate>.x86_64.rpm --reinstall</p><p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-14.2.520.3_k5.14.21_150500.37-1.sles15sp5.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>Rewrite of same Driver version has to be performed using --reinstall option</p><p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm --reinstall</p><p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"ja","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"},{"Lang":"cn","Value":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T12:12:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.7</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン14.4.473.7にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.7</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.7"},{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>SUSE Linux Enterprise 15 Service Pack 7</p><p>Updated to&nbsp;version 14.4.473.26</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>SUSE Linux Enterprise 15 Service Pack 7</p><p>Updated to&nbsp;version 14.4.473.26</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>SUSE Linux Enterprise 15 Service Pack 7</p><p>Updated to&nbsp;version 14.4.473.26</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.26"}],"SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"3f2193e2650146c4aa3a3ff8b1c516b3"}]},{"ProductId":"a1b0fb5619dd4bf685499171488aaaa2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000GXMTK and MB020000GXMTQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB018000GXMTK and MB020000GXMTQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19691219","DateModified":"2025-03-06T13:33:30","FileList":["/CP065977_BUILD_2.data","/CP065977.vmexe64","/CP065977.vmfile","/CP065977_VMw.zip","/CP065977.xml","/payload.json","/CP065977_VMw.zip/index.xml","/CP065977_VMw.zip/vendor-index.xml","/CP065977_VMw.zip/metadata.zip","/CP065977_VMw.zip/vib20/CP065977/HPE_bootbank_CP065977_HPG3.2-1OEM.800.1.0.20613240.vib","/CP065977_VMw.zip/metadata.zip/vendor-index.xml","/CP065977_VMw.zip/metadata.zip/vmware.xml","/CP065977_VMw.zip/metadata.zip/vibs/CP065977-6999833380529871258.xml","/CP065977_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065977_HPG3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"afdbf3fc20ce278ec1ff0f8ac34ea275","Name":"CP065977.zip","Release":"2025-03-06T13:32:35","Revision":"B","SHA1Sum":"cdcf72eea55f2627568cc99a63720dc0270d954f","SHA256Sum":"05295bb54a84bfb45039c64b6baed0c182d1236e433f15e1526af8990efef079","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP065977","Version":"HPG3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:11:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3997df854d184cccb8bf94004912f89b"}]},{"ProductId":"f5aa8733027b4498a80cd2e690d91986","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11580602","DateModified":"2025-05-14T04:11:33","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/CP067197.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/U31_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067197.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067197.scexe"],"MD5Sum":"598e102cbea8237f125b8aac14cc8ad3","Name":"firmware-system-u31-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-14T09:02:50","Revision":"B","SHA1Sum":"ec3818f1d6eb162bd7cc5e7eb9a95e78482b15c9","SHA256Sum":"de26e4f5baa19d53a304c543d73be9cfc34e033063ed4b5e819d72853527219c","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10（U31）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T09:01:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d639e5e4e65458ba7791a6f64b65c08"}]},{"ProductId":"67fb0d734fd248cca1eff5e7b321a8b6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Video"},{"Lang":"ja","Value":"ドライバ - ビデオ"},{"Lang":"cn","Value":"驱动程序 - 视频"}],"Description":[{"Lang":"en","Value":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"Lang":"ja","Value":"このコンポーネントは、Matrox G200eH3ビデオコントローラー対応の高度なビデオ機能を提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1631760","DateModified":"2025-06-30T08:18:21","FileList":["cp067682.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","mxg200eh.cat","MxG200eH.inf","MxG2hDO64.sys"],"MD5Sum":"aa15cc6da975c524874927eec2786891","Name":"cp067682.exe","Release":"2025-06-30T08:16:07","Revision":"C","SHA1Sum":"bf7f7eba7eb83e4744dc134dd8de8c03713c53d9","SHA256Sum":"c4c014ae7579012c21d0e1f8a98037c99f99fa69400969005c1b24d06fbcf2d1","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.268"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P><P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P><P>Click the \"Install\" button to perform the driver installation.</P>"},{"Lang":"ja","Value":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P><P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P><P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit"},{"Lang":"ja","Value":"Matrox G200eH3ビデオコントローラードライバーfor Microsoft Windows 64ビット"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"10000"},"SupportedDevices":[{"Dev":"0538","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-0538159000e4","Type":"pci","Ven":"102B"},{"Dev":"0538","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-102b-05381590027f","Type":"pci","Ven":"102B"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-07-30T08:14:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.268"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"9.15.1.268"}],"SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"16ea6f4c880e4feabd7c537e0d7d36d2"}]},{"ProductId":"eea0fcde2dfe4c0ebeb9ed47ea130474","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 8.0"},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;2.9.2.0.</p>"}],"Files":[{"Bytes":"309209","DateModified":"2024-09-06T02:42:33","FileList":["/cp063149.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/vendor-index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/vib20/i40en/INT_bootbank_i40en_2.9.2.0-1OEM.800.1.0.20613240.vib","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vmware.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/vibs/i40en-7395401369198326719.xml","/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240_24226995.zip/metadata.zip/bulletins/Intel-i40en_2.9.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"13d66d661146707e0c1a334343a0f9d7","Name":"cp063149.zip","Release":"2024-09-06T02:42:23","Revision":"","SHA1Sum":"3c3b5e4d762e20b6fdae73773db900f7e27221b7","SHA256Sum":"4a7cd388ff41903628a3bd6c241f7770e799c9386caadae6b6505efb8b217b9c","Size":"301KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2024.11.00","VibList":[{"Name":"i40en","Version":"2.9.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャ、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel i40en Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel i40enドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel i40en Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-05T07:36:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced to support log FW Failure Critical Data in Recovery Mode.</li><li>This product enhanced to support add module parameters pause_rx and pause_tx for Link Flow Control and enable it by default.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>この製品は、リカバリモードでFW障害のクリティカルデータのログ記録をサポートするように強化されました。</li><li>この製品は、リンクフロー制御用のモジュールパラメーターpause_rxおよびpause_txの追加をサポートし、デフォルトでそれを有効にするように強化されました。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced to support log FW Failure Critical Data in Recovery Mode.</li><li>This product enhanced to support add module parameters pause_rx and pause_tx for Link Flow Control and enable it by default.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2024.11.00"}],"SWKeys":[{"Name":"Intel-i40en:2.9.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.9.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"906179da97054dc693d9224a3452d494"}]},{"ProductId":"3d51e7d6b8674f16bd8f67bee278e11a","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900382","Version":"7.43"},{"DeviceName":"HPE_SR_Gen10_7.43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_7.43_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900383","Version":"7.43"}]},"MinimumActiveVersion":"5.61","Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Universal Firmware PLDM file for the Gen11 SR308i-o, SR308i-p controllers and Gen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-a and SR308i-o,SR308i-p Gen11 SR controllers"},{"Lang":"ja","Value":"ユニバーサルファームウェアPLDMファイルfor Gen11 SR308i-o, SR308i-pコントローラーおよびGen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-aおよびSR308i-o,SR308i-p Gen11 SRコントローラー"},{"Lang":"cn","Value":"Universal Firmware PLDM file for the Gen11 SR308i-o, SR308i-p controllers and Gen10 Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m, P816i-a and SR308i-o,SR308i-p Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"12107088","DateModified":"2025-02-06T05:49:50","FileList":["HPE_SR_Gen10_7.43_A.HPb","HPE_SR_Gen10_7.43_A.xml","payload.json"],"MD5Sum":"8bbb4dddc0997ff7b3a09d1d4933bbb1","Name":"HPE_SR_Gen10_7.43_A.fwpkg","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"e5d79079f0e00351c95871b49eabe99d1da65d36","SHA256Sum":"46ff24ab27a6d35ffe43fa56c299e7f96351b0f8507136bf793ae072675a3707","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f15900383"],"TypeOfChange":"1","Version":"7.43"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>&nbsp; &nbsp; Reboot the server for the firmware update to take effect.</p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://support.hpe.com/connect/s/product?language=en_US&kmpmoid=7630408&tab=driversAndSoftware&driversAndSoftwareFilter=8000078\">iLO Restfulインターフェイスツール</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>    ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>    ファームウェアアップデートを有効にするためにサーバーを再起動します。</p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>     アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://support.hpe.com/connect/s/product?language=en_US&amp;kmpmoid=7630408&amp;tab=driversAndSoftware&amp;driversAndSoftwareFilter=8000078\">iLO Restful Interface tool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>&nbsp; &nbsp; Reboot the server for the firmware update to take effect.</p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp; &nbsp; &nbsp;Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers"},{"Lang":"ja","Value":"ファームウェアパッケージ - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408e-m、P204i-c、P416ie-m、およびP816i-a SR Gen11コントローラー"},{"Lang":"cn","Value":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"12000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-15T05:24:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>SR 2.9.2 patch 1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>SR 2.9.2 パッチ 1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>SR 2.9.2 patch 1</p>","Fixes":"","Lang":"cn"}],"Version":"7.43"},{"ReleaseNotes":[{"Enhancements":"<ul><li>PLDM Base (Type 0) commands comply with v1.2.0 of the PLDM base specification (DSP0240).</li><li>PLDM Platform Monitoring and Control (Type 2) commands comply with v1.3.0 of the PLDM Platform Monitoring and Control Specification (DSP0248).</li><li>Long-running task support for volume creation/deletion using Redfish and storage resource RDE action operations.</li></ul>","Fixes":"<ul><li>Fixed an issue where a lockup occasionally occurs when RAID 0 Predictive Spare Rebuilding (PSR) starts.</li><li>Fixed an issue where the fault LED remains lit during the rebuild process of a replaced SSD drive.</li><li>Fixed an issue where the host was unable to retrieve new configuration updates after creating a logical drive on PF drives.</li><li>Fixed an issue where the logical volume status was incorrectly reported as OK on a secured volume if a data drive was replaced with an Otherwise Owned SED drive before reboot.</li><li>Fixed an issue where the surface scan period was not reset to default after factory reset.</li><li>Fixed an issue where the predictive failure drive did not fail even after the Predictive Spare Rebuild (PSR) was completed.</li><li>Fixed an issue where the Controller might have a potential lockup after a JBOD power cycle.</li><li>Fixed an issue where the offline replacement of a failed drive during a spare rebuild led to the failure of the replacement drive.</li><li>Fixed a lockup issue that could occur both during a transformation with an abrupt shutdown, and on subsequent bootup.</li><li>Fixed an intermittent MCTP communication issue during AC power cycle tests on specific configurations.</li><li>Fixed an MCTP communication issue in AMD Turin 2P configurations.</li><li>Fixed a lockup issue that could occur when a timeout occurs with expander attached SATA drives. &nbsp;</li><li>Fixed an issue with improper support checking for the secure erase command.</li><li>Fixed issues for missing active dedicated hot spare member in HII logical drive information and failed drive part of a logical drive in the HII disk utilities.</li><li>Fixed an issue which threw wrong error code, &#39;InternalError&rsquo; when creating an array on controller that is waiting on adapter password.</li><li>Fixed an issue When server is powered on with no drives connected to Enclosure. Observe incorrect controller information in iLO Storage tab &amp; Redfish</li><li>Fixed an issue that enclosures Link is missing under Storage URI in Redfish.</li><li>Fixed an issue in which drive resource does not match with Chassis for empty bay.</li><li>Fixed an issue in which incorrect severity warning of drive when sanitize erase operation is in progress.</li><li>Fixed an issue where HealthRollup shows warning during normal state.</li><li>Fixed an issue where CacheSummary.Status.Health shows incorrect during WriteCache degraded.</li><li>Fixed an issue in which PLDM/RDE Read sometimes take longer than 6s during array deletion.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>PLDMベース (タイプ 0) コマンドは、PLDM ベース仕様 (DSP0240) の v1.2.0 に準拠しています。</li><li>PLDM プラットフォーム監視および制御 (タイプ 2) コマンドは、PLDMプラットフォーム監視および制御仕様 (DSP0248) のv1.3.0に準拠しています。</li><li>RedfishおよびストレージリソースRDEアクション操作を使用したボリュームの作成/削除の長期実行タスクのサポート。</li></ul>","Fixes":"<ul><li>RAID 0予測スペア再構築(PSR)の開始時にロックアップが発生することがある問題を修正しました。</li><li>交換したSSDドライブの再構築プロセス中に障害LEDが点灯したままになる問題を修正しました。</li><li>PFドライブ上に論理ドライブを作成した後、ホストが新しい構成のアップデートを取得できない問題を修正しました。</li><li>再起動前にデータドライブがその他の所有者のSEDドライブに置き換えられた場合、セキュリティ保護されたボリュームの論理ボリューム ステータスが誤ってOKと報告される問題を修正しました。</li><li>工場出荷時の状態にリセットした後、表面スキャン期間がデフォルトにリセットされない問題を修正しました。</li><li>予測スペア再構築 (PSR) が完了した後でも予測障害ドライブが障害にならない問題を修正しました。</li><li>JBOD電源サイクル後にコントローラーがロックアップする可能性がある問題を修正しました。</li><li>スペア再構築中に故障したドライブをオフラインで交換すると、交換ドライブが故障する問題を修正しました。</li><li>突然のシャットダウンを伴う変換中とその後の起動時の両方で発生する可能性のあるロックアップの問題を修正しました。</li><li>特定の構成でのAC電源サイクルテスト中に断続的に発生するMCTP通信の問題を修正しました。</li><li>AMD Turin 2P構成におけるMCTP通信の問題を修正しました。</li><li>エキスパンダーが接続されたSATAドライブでタイムアウトが発生したときに発生する可能性のあるロックアップの問題を修正しました。 </li><li>セキュア消去コマンドの不適切なサポート チェックに関する問題を修正しました。</li><li>HII論理ドライブ情報にアクティブな専用ホットスペアメンバーが見つからない問題と、HIIディスクユーティリティの論理ドライブのドライブ部分に障害が発生する問題を修正しました。</li><li>アダプターパスワードを待機しているコントローラーでアレイを作成するときに、間違ったエラー コード「InternalError」が送られる問題を修正しました。</li><li>エンクロージャーにドライブが接続されていない状態でサーバーの電源がオンになった場合の問題を修正しました。iLOのストレージタブとRedfishで不正なコントローラー情報を確認</li><li>RedfishのストレージURIでエンクロージャーリンクが見つからない問題を修正しました。</li><li>空のベイのドライブリソースがシャーシと一致しない問題を修正しました。</li><li>サニタイズ消去操作の進行中にドライブの誤った重大度の警告が表示される問題を修正しました。</li><li>通常の状態でHealthRollupが警告を表示する問題を修正しました。</li><li>WriteCacheが劣化しているときにCacheSummary.Status.Healthが正しく表示されない問題を修正しました。</li><li>アレイの削除中にPLDM/RDE読み取りに6秒以上かかることがある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>PLDM Base (Type 0) commands comply with v1.2.0 of the PLDM base specification (DSP0240).</li><li>PLDM Platform Monitoring and Control (Type 2) commands comply with v1.3.0 of the PLDM Platform Monitoring and Control Specification (DSP0248).</li><li>Long-running task support for volume creation/deletion using Redfish and storage resource RDE action operations.</li></ul>","Fixes":"<ul><li>Fixed an issue where a lockup occasionally occurs when RAID 0 Predictive Spare Rebuilding (PSR) starts.</li><li>Fixed an issue where the fault LED remains lit during the rebuild process of a replaced SSD drive.</li><li>Fixed an issue where the host was unable to retrieve new configuration updates after creating a logical drive on PF drives.</li><li>Fixed an issue where the logical volume status was incorrectly reported as OK on a secured volume if a data drive was replaced with an Otherwise Owned SED drive before reboot.</li><li>Fixed an issue where the surface scan period was not reset to default after factory reset.</li><li>Fixed an issue where the predictive failure drive did not fail even after the Predictive Spare Rebuild (PSR) was completed.</li><li>Fixed an issue where the Controller might have a potential lockup after a JBOD power cycle.</li><li>Fixed an issue where the offline replacement of a failed drive during a spare rebuild led to the failure of the replacement drive.</li><li>Fixed a lockup issue that could occur both during a transformation with an abrupt shutdown, and on subsequent bootup.</li><li>Fixed an intermittent MCTP communication issue during AC power cycle tests on specific configurations.</li><li>Fixed an MCTP communication issue in AMD Turin 2P configurations.</li><li>Fixed a lockup issue that could occur when a timeout occurs with expander attached SATA drives. &nbsp;</li><li>Fixed an issue with improper support checking for the secure erase command.</li><li>Fixed issues for missing active dedicated hot spare member in HII logical drive information and failed drive part of a logical drive in the HII disk utilities.</li><li>Fixed an issue which threw wrong error code, &#39;InternalError&rsquo; when creating an array on controller that is waiting on adapter password.</li><li>Fixed an issue When server is powered on with no drives connected to Enclosure. Observe incorrect controller information in iLO Storage tab &amp; Redfish</li><li>Fixed an issue that enclosures Link is missing under Storage URI in Redfish.</li><li>Fixed an issue in which drive resource does not match with Chassis for empty bay.</li><li>Fixed an issue in which incorrect severity warning of drive when sanitize erase operation is in progress.</li><li>Fixed an issue where HealthRollup shows warning during normal state.</li><li>Fixed an issue where CacheSummary.Status.Health shows incorrect during WriteCache degraded.</li><li>Fixed an issue in which PLDM/RDE Read sometimes take longer than 6s during array deletion.</li></ul>","Lang":"cn"}],"Version":"7.43"}],"SWKeys":[{"Name":"03831590","SWKeyExpectedPath":"firmware"},{"Name":"03821590","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"1100103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"21b12f17270740e98bc0d546a55c851e"}]},{"ProductId":"0883e4abd7344c9b834b5e5585107933","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"ja","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"Lang":"cn","Value":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen11 controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2709311","DateModified":"2025-06-03T06:25:00","FileList":["./opt/MegaRAID/storcli/storcli","./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"MD5Sum":"db666ef4b75b07a72345da154e0cb47e","Name":"storcli-007.3210.0000.0000-1.noarch.rpm","Release":"2025-06-03T06:23:03","Revision":"C","SHA1Sum":"3eee45115800a9338222f9eb965ebb9e077c37bd","SHA256Sum":"51ba907758ef133575f85d749d774f1eca0dbdac3247752b90971160337408fb","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3210.0000.0000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li><li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li></ul>"},{"Lang":"ja","Value":"<ul><li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li><li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li></ul>"},{"Lang":"cn","Value":"<ul><li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li><li>To install the StorCLI RPM, run the rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/MegaRAID/storcli and the executable name is storcli64.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support new Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"007.3011.0000.0000"},{"ReleaseNotes":[{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>7.32 PR8 RC Drop</p>","Fixes":"","Lang":"cn"}],"Version":"007.3210.0000.0000"}],"SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4dfd7e5af5864f6ea849747f171f690f"}]},{"ProductId":"d8cf5e47a4564ba6bcb2ea1177a33ff1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33603576","DateModified":"2025-06-16T02:28:16","FileList":["payload.json","U46_2.42_06_13_2025.signed.flash","U46_2.42_06_13_2025.xml"],"MD5Sum":"e6a9ce855352f06cadbc665a3b48b6ce","Name":"U46_2.42_06_13_2025.fwpkg","Release":"2025-06-16T02:24:21","Revision":"","SHA1Sum":"05c9f0d14b9e93d99e06b679c06d81801d998e29","SHA256Sum":"955792c95bd8c705275da71823eda6baf5b3acee798d3281d24dd0bd6e377b4e","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:24:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"6b9f622899434c4285ba9886607fd35f"}]},{"ProductId":"cd7426f38f994cdda68f5e95f6cadf0f","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK3"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK3"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO000960KWVBR, VO001920KWVBT and VO003840KWVBU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p style=\"text-align:left\"><strong>Known Issues:</strong></p><p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li></ul><p style=\"text-align:left\"><strong>Known Issues:</strong></p><p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>"}],"Files":[{"Bytes":"5748729","DateModified":"2025-05-14T07:05:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/CP066546.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/KACD5ALSHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a9843986b0-HPK3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066546.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066546.scexe"],"MD5Sum":"cf6bf0b49fd01aea74ba1a30df604715","Name":"firmware-hdd-a9843986b0-HPK3-5.1.x86_64.rpm","Release":"2025-05-14T11:42:04","Revision":"E","SHA1Sum":"79c2f5efc1e114ce37fb35119b28e83f172a45f8","SHA256Sum":"a9d186b789945d3909c8469e502dea6b406ae8984c06ab76538b4a26ad9169ee","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"CP041863.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO000960KWVBR","TargetGUID":"562340a5-304f-3030-3936-304b57564252","Type":"nvme"},{"Id":"VO003840KWVBU","TargetGUID":"562340a5-304f-3330-3834-304b57564255","Type":"nvme"},{"Id":"VO001920KWVBT","TargetGUID":"562340a5-304f-3130-3932-304b57564254","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T13:43:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWVBR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWVBT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWVBU","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3628482546184f4db1d036f891e61189"}]},{"ProductId":"fde211973c7e4009ac1207f980953529","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix contains code improvements for SMART reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5997965","DateModified":"2025-05-14T05:27:12","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/CP066588.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066588.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066588.scexe"],"MD5Sum":"0b342d087ef7cdb4bcf0d447737e8fdd","Name":"firmware-hdd-492a9952f6-HPG5-4.1.x86_64.rpm","Release":"2025-05-14T10:14:24","Revision":"D","SHA1Sum":"e09080ebd3252788d8ecd63a7e28c2f99872dfa2","SHA256Sum":"7a3a2de8aad6b9355a308bda5f0bf2833513f9890057bca828cac0371c0d65a7","Size":"5MB","TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"Installation":{"Command":"CP041497.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK003840GWTHD","TargetGUID":"562340a5-304b-3330-3834-304757544844","Type":"sata"},{"Id":"VK001920GWTHC","TargetGUID":"562340a5-304b-3130-3932-304757544843","Type":"sata"},{"Id":"VK000960GWTHB","TargetGUID":"562340a5-304b-3030-3936-304757544842","Type":"sata"},{"Id":"VK000480GWTHA","TargetGUID":"562340a5-304b-3030-3438-304757544841","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T06:18:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正には、SMARTレポートのコードの改善が含まれています。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix contains code improvements for SMART reporting.</li></ul>","Lang":"cn"}],"Version":"HPG5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG5"}],"SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e130ff57fb12428e851927460d468897"}]},{"ProductId":"7ebf7b3b32234babb113c6746f09f68e","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11874318","DateModified":"2025-05-14T21:22:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/CP067207.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/U38_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067207.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067207.scexe"],"MD5Sum":"c102b036b8129649dbac7b1bb6faa218","Name":"firmware-system-u38-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T02:12:08","Revision":"B","SHA1Sum":"a898da1e08d180a42a0d648e0fd8f225871658b8","SHA256Sum":"c8bb6692c5ea6c943c7e70682d258407800ac2ab50cd36488c2d13f077e58df6","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T02:04:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"88ed60874ab34b78a5d733fdb9632ca1"}]},{"ProductId":"e99fcbdfe7054c0191086c267b0b5462","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17125412","DateModified":"2025-05-20T07:26:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/CP067166.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/U61_2.40_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.40_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067166.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067166.scexe"],"MD5Sum":"529e2f05a3f614352e9355e5c0e542a3","Name":"firmware-system-u61-2.40_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-20T12:16:37","Revision":"","SHA1Sum":"cd993f30fb5006fa59df540959535d68e62253a7","SHA256Sum":"deed1e4852a46742ef7e1b7e2fa36a7ad90dfeb0da8da8c0470d065842b5df2b","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML30 Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:33:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"224fa842e50c42a193a21ca70a75102d"}]},{"ProductId":"21c71338fdf2430b8b41f3737620822c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"614056","DateModified":"2025-07-01T08:02:14","FileList":["cp067691.xml","cpqsetup.exe","installer.dll","pnp/","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"MD5Sum":"bc02005bb0c24e42c66693a2daead47c","Name":"cp067691.exe","Release":"2025-07-01T08:00:11","Revision":"E","SHA1Sum":"911db84b186ec6e55b4ea34e4a7e06a810e3e4db","SHA256Sum":"dd16dba7e8ccfe77624a0d94a1cb59523094c87925445cdfb47e9ac351254fb5","Size":"599KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19006.8299"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第1および第2世代）識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-01T07:58:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19006.8299"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19006.8299"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d9ea672369d74105a09ca946a025357e"}]},{"ProductId":"bdb6e242313a47b89b69823cf9ad3729","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサー内のデバイスを識別するためのドライブなしのINFをインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"673968","DateModified":"2025-07-01T09:28:18","FileList":["cp067695.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/amddrtm.cat","pnp/amddrtm.dll","pnp/amddrtm.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"MD5Sum":"0df684c3b7734075e20b0b4e8dc3a6e4","Name":"cp067695.exe","Release":"2025-07-01T09:26:18","Revision":"C","SHA1Sum":"4dfe7625c67485c35b7d9fabb4a6a81268e63f94","SHA256Sum":"ff8930591caf9bd1d842473aa9b861424221e9db10224e272494b77bd8d5ef49","Size":"658KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"1","Version":"6.10.8.431"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows Server 2022 and 2025"},{"Lang":"ja","Value":"AMD EPYC プロセッサー（第3世代）識別子for Microsoft Windows Server 2022および2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-01T09:24:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.10.8.431"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.10.8.431"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c5f8aab8e5b44d3489812dc34e1945db"}]},{"ProductId":"957b79699cf847b3bc804b96d1108938","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Chipset"},{"Lang":"ja","Value":"ドライバ - チップセット"},{"Lang":"cn","Value":"驱动程序 - 芯片组"}],"Description":[{"Lang":"en","Value":"This component installs driverless INFs to identify devices in the processor and chipset."},{"Lang":"ja","Value":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"635720","DateModified":"2025-07-01T08:17:21","FileList":["cp067692.xml","cpqsetup.exe","installer.dll","pnp/","pnp/IceLakeX.cat","pnp/IceLakeXSystem.inf","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Server_Common.cat","pnp/Server_CommonSystem.inf","pnp/Server_CommonSystemNorthpeak.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"MD5Sum":"d3977da18c19f815d180718ac91aeba6","Name":"cp067692.exe","Release":"2025-07-01T08:15:19","Revision":"C","SHA1Sum":"0220c478394c125fb85fd7b2bfa6819e6978621e","SHA256Sum":"339dcb4dbf932ce889cd9cbf8d973a3b16223e0670012b80330779d4d4fe27b1","Size":"620KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19879.8585"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":3600,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<p>From that drive and directory, execute the downloaded file. <p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows"},{"Lang":"ja","Value":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第3世代）識別子"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-01T08:13:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19879.8585"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"10.1.19879.8585"}],"SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"495f8cb1681b441e8b227e05d2fc5892"}]},{"ProductId":"0e486c09859842e29ba327f60bd15f9a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD3"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD3"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"}],"Files":[{"Bytes":"6530840","DateModified":"2025-05-14T08:15:48","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/CP066555.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/SCIMARBPESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066555.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066555.scexe"],"MD5Sum":"8f12fe10edf85a2b532008f0e859b197","Name":"firmware-hdd-b04df66fe9-HPD3-3.1.x86_64.rpm","Release":"2025-05-14T13:04:04","Revision":"C","SHA1Sum":"b7f2e27e6e48931422453b9b5451dd15acf30191","SHA256Sum":"860373d3e5c9ee844ad47d9ea4b605f07596949e0b92410f4b5e1d916008921c","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD3"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000JYDNF、MB008000JYDPCおよびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:35:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。</li><li>その他のログ機能とFW機能強化を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9a1c6d265a394ca9a79b3d9f244b91d0"}]},{"ProductId":"33bf4058d2284d31ad166fd3619cf008","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD9"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG07scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD9"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWTFDおよびMB012000JWTFC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD8<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18204334","DateModified":"2025-03-07T11:15:41","FileList":["/CP065933_BUILD_4.data","/CP065933.vmexe64","/CP065933.vmfile","/CP065933_VMw.zip","/CP065933.xml","/payload.json","/CP065933_VMw.zip/index.xml","/CP065933_VMw.zip/vendor-index.xml","/CP065933_VMw.zip/metadata.zip","/CP065933_VMw.zip/vib20/CP065933/HPE_bootbank_CP065933_HPD9.4-1OEM.800.1.0.20613240.vib","/CP065933_VMw.zip/metadata.zip/vendor-index.xml","/CP065933_VMw.zip/metadata.zip/vmware.xml","/CP065933_VMw.zip/metadata.zip/vibs/CP065933--4425965417693300476.xml","/CP065933_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065933_HPD9.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c3e4e9c74554c9b7b37d1210a6ac6f88","Name":"CP065933.zip","Release":"2025-03-07T11:14:57","Revision":"B","SHA1Sum":"0a880564f8859dd22d91388d8b26bdb66ee28e9d","SHA256Sum":"615e0883ab2a46ded978cf7c8e14f6274da470138ef0cc1d26c9ed30f4da6b04","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP065933","Version":"HPD9.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JWTFD","TargetGUID":"4d2340a5-3042-3431-3030-304a57544644","Type":"sas"},{"Id":"MB012000JWTFC","TargetGUID":"4d2340a5-3042-3231-3030-304a57544643","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:46:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。 このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。 </li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.&nbsp;The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.&nbsp;</li></ul>","Lang":"cn"}],"Version":"HPD9"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD9"}],"SWKeys":[{"Name":"MB014000JWTFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWTFC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d0b0db6f4a2548e58abb55a12af0bf2a"}]},{"ProductId":"9ea83d5d4cdf449690664479d7c8538a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6412496","DateModified":"2025-05-14T08:39:40","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/CP066561.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066561.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066561.scexe"],"MD5Sum":"5af23488fe1393bb97d7bfbd37e10794","Name":"firmware-hdd-a886842a99-HPD2-9.1.x86_64.rpm","Release":"2025-05-14T13:27:52","Revision":"I","SHA1Sum":"c2950c03f7a4448d2f045ddf4816af38bcd8522f","SHA256Sum":"81b4019e2ebd3858823e481a018e0eb568467021bbbad9209cad39c7f92b1f17","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041488.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB006000JWKGN ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB006000JWKGN","TargetGUID":"4d2340a5-3042-3630-3030-304a574b474e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T19:09:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"293c2472d0e644839c5bb2975a3779ea"}]},{"ProductId":"fcc57b2588b04f54a01cb383a7a5a458","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWCBCおよびMB002000GWCBD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20090103","DateModified":"2025-03-07T06:38:06","FileList":["/CP065938_BUILD_3.data","/CP065938.vmexe64","/CP065938.vmfile","/CP065938_VMw.zip","/CP065938.xml","/payload.json","/CP065938_VMw.zip/index.xml","/CP065938_VMw.zip/vendor-index.xml","/CP065938_VMw.zip/metadata.zip","/CP065938_VMw.zip/vib20/CP065938/HPE_bootbank_CP065938_HPG6.3-1OEM.800.1.0.20613240.vib","/CP065938_VMw.zip/metadata.zip/vendor-index.xml","/CP065938_VMw.zip/metadata.zip/vmware.xml","/CP065938_VMw.zip/metadata.zip/vibs/CP065938-4188264763430447489.xml","/CP065938_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065938_HPG6.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"f3d2f4bd84301ce5d060357fbfc559cf","Name":"CP065938.zip","Release":"2025-03-07T06:37:20","Revision":"J","SHA1Sum":"042dfd9a6b60e92a476603b01ff25482b3632520","SHA256Sum":"7e46247c9fcba4ae0b5afc88222e9ea6a4b366bf0181f02fc351c555a8b5777a","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP065938","Version":"HPG6.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040784.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB001000GWCBC","TargetGUID":"4d2340a5-3042-3130-3030-304757434243","Type":"sata"},{"Id":"MB002000GWCBD","TargetGUID":"4d2340a5-3042-3230-3030-304757434244","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:55:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWCBC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWCBD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"221ac2d459d745f6aba61fbb6f98226a"}]},{"ProductId":"f0e80dda550e422981f666fd854cb6f6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3661872","DateModified":"2025-03-25T22:09:13","FileList":["cp066511.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCQssssASFD2.rel"],"MD5Sum":"88547ebb5e880c8a7641554887c40a01","Name":"cp066511.exe","Release":"2025-03-25T22:04:08","Revision":"B","SHA1Sum":"7ef8875f13baf4385d30aaf4f5a5fcf7c35c2f5c","SHA256Sum":"89d6105849fd51f4dc55a090da07e410464ea1a4f3b24a58825a01b6a5e322a7","Size":"3MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"2","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:50:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、CBが次のURLで公開されています。https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3496fbf9e27e44d29a09b5f37e69a7c7"}]},{"ProductId":"a3ac88993616476a8dcf9b3fac5ea67c","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"233.1.135007"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs firmware running under Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2022およびWindows Server 2025で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"10275288","DateModified":"2025-04-09T02:33:15","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp066634.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"62fa941c093ab37ce5b89469fd912a4a","Name":"cp066634.exe","Release":"2025-04-09T02:24:57","Revision":"","SHA1Sum":"aca974c000c242b13d598a4c28167eb513c1fd94","SHA256Sum":"1377451c618d69d667cf90315163a2e4da6947691db5a9fadfc3fb570aec4b02","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.4.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p> </p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p><p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p><p><strong><em>追加情報:</em></strong></p><ul><li>ファームウェアをアップグレードする場合は、リビジョン履歴を参照し、必要なバージョンまで一つずつアップグレードしていきます。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5400"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-01T09:12:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanIdプロパティを削除します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断を向上させます。</li><li>この製品は、よりクリーンなインターフェイスを実現するために、HII MBAメニューを抑制するドライバーのアップデートを強化しています。</li></ul>","Fixes":"<ul><li>この製品は、RDMA接続が確立されない問題を修正します。</li><li>この製品は、RoCEおよびTX/RXパスコアダンプのデコードが失敗する問題を修正します。</li><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、VLAN構成でPXEブートが機能しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"cn"}],"Version":"5.4.4.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.4.5.0"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"d80625c54c674329a1f7381d469fbc90"}]},{"ProductId":"a83500e26a4d4bb89a4eb5821b7b2ca6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Operating System - Enhancements"},{"Lang":"ja","Value":"オペレーティング システム - 拡張"},{"Lang":"cn","Value":"操作系统 - 增强功能"}],"Description":[{"Lang":"en","Value":"This components installs the AMD PSHED service"},{"Lang":"ja","Value":"このコンポーネントはAMD PSHEDサービスをインストールします"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"631488","DateModified":"2025-06-30T08:14:18","FileList":["cp067540.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"MD5Sum":"9a700f5ee21027b52e859a8dd37a9fa6","Name":"cp067540.exe","Release":"2025-06-30T08:12:27","Revision":"C","SHA1Sum":"43455ae32edd57f505b391732baa297a025e1c53","SHA256Sum":"c92e80a571a022925f6b6dc26dcea23e38fcf1d9664629c494b794555e4a5929","Size":"616KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>[インストール]ボタンをクリックして、インストールを開始します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"AMD PSHED Plug-in service for Microsoft Windows Server 2022 and 2025"},{"Lang":"ja","Value":"AMD PSHEDプラグインサービスfor Microsoft Windows Server 2022および2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-07-11T08:16:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated&nbsp;Supported Environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Supported Platforms</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポートされているプラットフォームを追加</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Supported Platforms</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.51"}],"SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ceee48d27fde4103906af6b3f8114b3c"}]},{"ProductId":"83f19a40734047f1a91d25f9cd465999","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.33.41"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under VMware VMware vSphere 8.0 and VMware vSphere 9.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 8.0およびVMware vSphere 9.0で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs firmware running under VMware VMware vSphere 8.0 and VMware vSphere 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"11877500","DateModified":"2025-04-07T08:16:16","FileList":["/CP066652_BUILD_3.data","/CP066652.vmexe64","/CP066652.vmfile","/CP066652_VMw.zip","/CP066652.xml","/payload.json","/CP066652_VMw.zip/index.xml","/CP066652_VMw.zip/vendor-index.xml","/CP066652_VMw.zip/metadata.zip","/CP066652_VMw.zip/vib20/CP066652/HPE_bootbank_CP066652_1.42.0.3-8.0.0.20613240.vib","/CP066652_VMw.zip/metadata.zip/vendor-index.xml","/CP066652_VMw.zip/metadata.zip/vmware.xml","/CP066652_VMw.zip/metadata.zip/vibs/CP066652-8235507153380860736.xml","/CP066652_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066652_1.42.0.3-8.0.0.20613240.xml"],"MD5Sum":"f98fd3877be245c4eec3c89e3bb35341","Name":"CP066652.zip","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"6661312e965583983f04de9ce7663b93261d418f","SHA256Sum":"207aa0735c6c6491843c1c0b7da2ca40ca588750ce93531f016af4de66e8c761","Size":"11MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"1.42.0","VibList":[{"Name":"CP066652","Version":"1.42.0.3-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"Broadcom NX1オンラインファームウェアアップグレードユーティリティfor VMware"},{"Lang":"cn","Value":"Broadcom NX1 Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1657","SubDev":"159D","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e4159d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1591","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41591","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"1590","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165714e41590","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"159C","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f14e4159c","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:33:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"1.42.0"}],"SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U47","Model":"HPE ProLiant DX220n Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DX380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DX385 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DX325 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant DX360 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0c5266fe33784696817b5c7a558e145d"}]},{"ProductId":"05a81ac262384916b1fa6e922a6cada6","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6154673","DateModified":"2025-05-14T07:19:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/CP066553.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066553.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066553.scexe"],"MD5Sum":"e0792e490aad9f4d4764f17774b7ac1b","Name":"firmware-hdd-6b7ce3da0e-HPG2-13.1.x86_64.rpm","Release":"2025-05-14T11:55:04","Revision":"M","SHA1Sum":"2e8b01ea77d22ca737889135b1d7ffed0527f7f6","SHA256Sum":"2c272ed50fd3c6b1ebb65e4ec46699242ac63945d401572a4b8ab5d9cef63b1e","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"CP041455.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB014000GWRTN","TargetGUID":"4d2340a5-3042-3431-3030-30475752544e","Type":"sata"},{"Id":"MB012000GWRTL","TargetGUID":"4d2340a5-3042-3231-3030-30475752544c","Type":"sata"},{"Id":"MB010000GWRTK","TargetGUID":"4d2340a5-3042-3031-3030-30475752544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T14:59:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2750331d1d3248c3af845c332d0282ff"}]},{"ProductId":"f6fccbc5aefd411688310b509bfaeaec","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB018000GXMTK and MB020000GXMTQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB018000GXMTKおよびMB020000GXMTQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB018000GXMTK and MB020000GXMTQ&nbsp;Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5905146","DateModified":"2025-05-14T08:38:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/CP066560.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066560.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066560.scexe"],"MD5Sum":"f5a9dd41207ac36797a6003baca9d420","Name":"firmware-hdd-3496cc4743-HPG3-2.1.x86_64.rpm","Release":"2025-05-14T13:27:27","Revision":"B","SHA1Sum":"4cae68a3f8e7c7e9a33c2823a9655a3768720a17","SHA256Sum":"cf119844bc504ef6a2a73cda2d0aeafb10c1b690995fe03ab465b76f00f5be2a","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"CP041696.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは'.rpm'拡張子なしのrpmファイル名です。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>rpmの内容を<em>rpm2cpio .rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB018000GXMTKおよびMB020000GXMTQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB020000GXMTQ","TargetGUID":"4d2340a5-3042-3032-3030-3047584d5451","Type":"sata"},{"Id":"MB018000GXMTK","TargetGUID":"4d2340a5-3042-3831-3030-3047584d544b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T18:55:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Assertの修正、現在のファームウェアの改善、およびバグ修正を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix to Assert fixes, current firmware improvements and bug fixes.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0029a52c5700479b9716d68ba90cb3ac"}]},{"ProductId":"fdb3892daac8474c8262b342acf8f35f","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"233.1.135007"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"233.1.135007"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"233.1.135007"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"233.1.135007"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet firmware running under VMware vSphere 8.0 and VMware vSphere 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet firmware running under VMware vSphere 8.0 and VMware vSphere 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet firmware running under VMware vSphere 8.0 and VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16426611","DateModified":"2025-04-09T03:42:19","FileList":["/CP066633_BUILD_5.data","/CP066633.vmexe64","/CP066633.vmfile","/CP066633_VMw.zip","/CP066633.xml","/payload.json","/CP066633_VMw.zip/index.xml","/CP066633_VMw.zip/vendor-index.xml","/CP066633_VMw.zip/metadata.zip","/CP066633_VMw.zip/vib20/CP066633/HPE_bootbank_CP066633_5.26.0.5-8.0.0.20613240.vib","/CP066633_VMw.zip/metadata.zip/vendor-index.xml","/CP066633_VMw.zip/metadata.zip/vmware.xml","/CP066633_VMw.zip/metadata.zip/vibs/CP066633-6595709260956685459.xml","/CP066633_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066633_5.26.0.5-8.0.0.20613240.xml"],"MD5Sum":"e02a51afe4aba774c00697c31604367e","Name":"CP066633.zip","Release":"2025-04-09T03:41:39","Revision":"","SHA1Sum":"a5a1dbcd2f5684df2c4b8ae7a52d6fba31b7816e","SHA256Sum":"bb3b02fd5e519faf3915584884ac01c3cae6dc975ac7934c6736c143e1250b68","Size":"15MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.26.0","VibList":[{"Name":"CP066633","Version":"5.26.0.5-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンライン ファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-01T09:12:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanIdプロパティを削除します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断を向上させます。</li><li>この製品は、よりクリーンなインターフェイスを実現するために、HII MBAメニューを抑制するドライバーのアップデートを強化しています。</li></ul>","Fixes":"<ul><li>この製品は、RDMA接続が確立されない問題を修正します。</li><li>この製品は、RoCEおよびTX/RXパスコアダンプのデコードが失敗する問題を修正します。</li><li>この製品は、ESXiでポート1がブロードキャストパケットを受信できない問題を修正します。</li><li>この製品は、システム内でOCPモジュールのリンク幅が低下する問題を修正します。</li><li>この製品は、VLAN構成でPXEブートが機能しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to streamline configuration.</li><li>This product enhances the coredump feature in the BNXT driver for improved diagnostics.</li><li>This product enhances to update the driver to suppress the HII MBA menu for a cleaner interface.</li></ul>","Fixes":"<ul><li>This product fixes the issue where RDMA connections are not getting connected.</li><li>This product fixes the issue where RoCE and TX/RX path core dump decoding failed.</li><li>This product fixes the issue where Port 1 was not receiving broadcast packets with ESXi.</li><li>This product fixes the issue where the OCP module experiences link width degradation in the system.</li><li>This product fixes the issue where PXE boot does not work with VLAN configurations.</li></ul>","Lang":"cn"}],"Version":"5.25.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"5.26.0"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1ae936910f9e439ca24742f29b3450a6"}]},{"ProductId":"fd79732b69c747a4ba4278e32ef12a49","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントには、Mircosoft Windows Server 2025用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"},{"Lang":"cn","Value":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1095304","DateModified":"2025-04-07T02:13:20","FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp066628.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"f65e91c6f2dbc9a906a77326427ce04d","Name":"cp066628.exe","Release":"2025-04-07T01:59:05","Revision":"","SHA1Sum":"493282ce33f6c12e32d91c4caa5b11651f08a7b1","SHA256Sum":"9bc88d180b7bae83808d5aada26c84aa4739b28613f1ef84c57fc15ab6b270ae","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"233.0.148.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41592","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e124","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181b14e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c514e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"1760","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e41760","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D6","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41593","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41592","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1819","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-181914e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41595","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41594","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41597","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c114e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc14e41596","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41599","Type":"pci","Ven":"14e4"},{"Dev":"1808","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180814e41598","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41599","Type":"pci","Ven":"14e4"},{"Dev":"1809","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180914e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1751","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41751","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41599","Type":"pci","Ven":"14e4"},{"Dev":"1806","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180614e41598","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41599","Type":"pci","Ven":"14e4"},{"Dev":"1807","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180714e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1808","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180800000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"},{"Dev":"1809","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-180900000000","Type":"pci","Ven":"14E4"},{"Dev":"181B","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-181B00000000","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、NXEファミリデバイスの一貫したPTPクロックのレポートを強化します。</li><li>この製品は、必要なPNP IDを追加することでデバイスの互換性を強化します。</li></ul>","Fixes":"<p>この製品は、未使用のrelease.txtファイルが削除されない問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances the reporting of a consistent PTP clock for NXE family devices.</li><li>This product enhances device compatibility by adding the necessary PNP ID.</li></ul>","Fixes":"<p>This product fixes the issue where an unused release.txt file was not removed.</p>","Lang":"cn"}],"Version":"232.0.155.7"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.148.0"}],"SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"8519d4c8f9834637a822cf2eaad01e46"}]},{"ProductId":"c0403221bbc14b609f9dc339f216be5e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM1000GFJTE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000GFJTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p><p><strong><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br /><br /><strong><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong>Previous Version of Firmware:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br /><br /><strong><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19186095","DateModified":"2025-03-06T06:07:03","FileList":["/CP066002_BUILD_3.data","/CP066002.vmexe64","/CP066002.vmfile","/CP066002_VMw.zip","/CP066002.xml","/payload.json","/CP066002_VMw.zip/index.xml","/CP066002_VMw.zip/vendor-index.xml","/CP066002_VMw.zip/metadata.zip","/CP066002_VMw.zip/vib20/CP066002/HPE_bootbank_CP066002_HPG6.3-1OEM.800.1.0.20613240.vib","/CP066002_VMw.zip/metadata.zip/vendor-index.xml","/CP066002_VMw.zip/metadata.zip/vmware.xml","/CP066002_VMw.zip/metadata.zip/vibs/CP066002-8352906547692875396.xml","/CP066002_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066002_HPG6.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5f7cbd5644245c700e5828ec381f004a","Name":"CP066002.zip","Release":"2025-03-06T06:06:14","Revision":"E","SHA1Sum":"91d3e1c35a3f8473f9626b05fde6c85dbe7beca7","SHA256Sum":"aa49d4039d92653428e9cb770a9b841c37e232d1eb399c3374caf0ac25b3d955","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-3047464a5445"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP066002","Version":"HPG6.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041026.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000GFJTEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000GFJTE","TargetGUID":"002340a5-4d00-314d-3030-3047464a5445","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:01:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MM1000GFJTE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f892951743024df2afb45434cce22ed5"}]},{"ProductId":"58f3059c65eb403984076353b9f058af","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-30525852514b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-305258525248","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-30525852524b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525852514c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525852524c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525852524e","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305259455744","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MO000960RXRQK、MO001920RXRRH、MO003840RXRRK、VO000960RXRQL、VO001920RXRRL、VO003840RXRRN、およびVO007680RYEWD"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD3</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2140748","DateModified":"2025-02-19T17:31:16","FileList":["payload.json","Seagate_Cooper_SCOOPRHPESD4.HPb","Seagate_Cooper_SCOOPRHPESD4.xml"],"MD5Sum":"5ff1a86b03cb98848d7a4184c30acfb8","Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","Release":"2025-02-19T17:29:17","Revision":"B","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"TypeOfChange":"2","Version":"HPD4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MO000960RXRQK、MO001920RXRRH、MO003840RXRRK、VO000960RXRQL、VO001920RXRRL、VO003840RXRRN、VO007680RYEWD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MO000960RXRQK","TargetGUID":"4d2340a5-304f-3030-3936-30525852514b","Type":"sas"},{"Id":"MO001920RXRRH","TargetGUID":"4d2340a5-304f-3130-3932-305258525248","Type":"sas"},{"Id":"MO003840RXRRK","TargetGUID":"4d2340a5-304f-3330-3834-30525852524b","Type":"sas"},{"Id":"VO000960RXRQL","TargetGUID":"562340a5-304f-3030-3936-30525852514c","Type":"sas"},{"Id":"VO001920RXRRL","TargetGUID":"562340a5-304f-3130-3932-30525852524c","Type":"sas"},{"Id":"VO003840RXRRN","TargetGUID":"562340a5-304f-3330-3834-30525852524e","Type":"sas"},{"Id":"VO007680RYEWD","TargetGUID":"562340a5-304f-3730-3638-305259455744","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T18:48:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</li></ul><p>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us&nbsp;</a></p>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>修正方法 - IO実行中に優先度の低いコマンドが頻繁に挿入されると、ドライブがランダムにオフラインになる可能性があります。</li></ul><p>詳しくは、HPEカスタマーアドバイザリ: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us </a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>To fix - Frequent insertion of low priority commands during IO execution may lead to drive offline randomly.</li></ul><p>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00141941en_us&nbsp;</a></p>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MO000960RXRQK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXRRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXRRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXRQL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXRRL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXRRN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680RYEWD","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Critical"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"351d50a2bba345ebbd72893c5d1e177f"}]},{"ProductId":"1e4f77062f4d48c8906f4212d8016a76","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33993990","DateModified":"2025-05-21T08:30:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/A48_3.72_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/CP067159.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-3.72_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067159.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067159.scexe"],"MD5Sum":"fe4b389793cfde1424f29508ecec7112","Name":"firmware-system-a48-3.72_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"cfd93143f2a1b031ee88b3634fc35913fb5830c3","SHA256Sum":"f0289b8ba0b660925574d5768e9ab43546cfc04acd3e89e9bb8d35f42f8a6f80","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0ed31a17a05440c6a4ecf338acf97e7c"}]},{"ProductId":"c5181c3bc0654e9db312aa6200639426","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9233336","DateModified":"2025-05-21T01:39:14","FileList":["cp067178.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_3.60_05_16_2025.signed.flash"],"MD5Sum":"06af529dcf74840ed420add159d1086b","Name":"cp067178.exe","Release":"2025-05-21T01:37:20","Revision":"","SHA1Sum":"14e450851575f2e12609ce903eda03e60d7fa5e6","SHA256Sum":"bbc81cdc106e4e472c5c0a2cdcd6ca6ef2ca7620e89b528fd7a50d9230cf2b47","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:41:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"1f6144b631ae4a278d4ebeb03344b3ff"}]},{"ProductId":"11f86ddaaa3742028089d7f3e7f71098","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE NVIDIA VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"23925274","DateModified":"2025-06-16T12:52:39","FileList":["/CP067551.vmexe64","/CP067551.vmfile","/CP067551.xml","/CP067551_VMw.zip","/payload.json","/CP067551_VMw.zip/index.xml","/CP067551_VMw.zip/vendor-index.xml","/CP067551_VMw.zip/metadata.zip","/CP067551_VMw.zip/vib20/CP067551/HPE_bootbank_CP067551_1.0.2-1OEM.900.0.24580437.vib","/CP067551_VMw.zip/metadata.zip/vendor-index.xml","/CP067551_VMw.zip/metadata.zip/vmware.xml","/CP067551_VMw.zip/metadata.zip/vibs/CP067551--760214194639140708.xml","/CP067551_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067551_1.0.2-1OEM.900.0.24580437.xml"],"MD5Sum":"513dad70332002ab0a1bc2bd8c17bd67","Name":"CP067551.zip","Release":"2025-06-16T12:53:56","Revision":"","SHA1Sum":"2003e0021be7f6b9c395ddeb0af27e0346a09267","SHA256Sum":"e88b05da67895cbf7df3d70c8aa74d80daa51fa6a7922aafe7524a9e7b5536bd","Size":"22MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.2","VibList":[{"Name":"CP067551","Version":"1.0.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.0"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.0"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"13000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T11:50:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2026にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"1.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.2"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2d3ded14cd644e28b76f26e6532a24fa"}]},{"ProductId":"96868d9680c84d50b81011a5d4811094","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3273432","DateModified":"2025-01-11T03:02:21","FileList":["cp065055.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TTMRNSD4.REL"],"MD5Sum":"979bf27ade4bddaa82c8a1dc0974342a","Name":"cp065055.exe","Release":"2025-01-11T02:57:36","Revision":"K","SHA1Sum":"cbb7831b206e0a41829d8a1f45c57ebe3bc9cc0e","SHA256Sum":"bd6b13e160fdb64fb3e572706bf6f5e54f41320b7ec37ab8e4964723d637c1dc","Size":"3MB","TargetGUIDs":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB2000JFDSL","TargetGUID":"002340a5-4d00-3242-3030-304a4644534c","Type":"sas"},{"Id":"MB4000JFDSN","TargetGUID":"002340a5-4d00-3442-3030-304a4644534e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:20:06","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB2000JFDSL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB4000JFDSN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8a6701a03c28432085e481e36d9a1c7e"}]},{"ProductId":"188f54d508794fafbb14f21866a0ffb5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6403487","DateModified":"2025-05-14T08:40:10","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/CP066562.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066562.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066562.scexe"],"MD5Sum":"b26fa11640bd8279ab25f8ac6b473525","Name":"firmware-hdd-2c27a7a9a4-HPD2-9.1.x86_64.rpm","Release":"2025-05-14T13:28:12","Revision":"I","SHA1Sum":"064f5d0f9fde3887fd2835aa2cc374dd03751a58","SHA256Sum":"54d1db6efd0ebfdeb87f6833fa8f71b638d3da11b452d00a13c441b0e3932cc1","Size":"6MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041491.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000JWKGU ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T19:10:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0e7b7692d1d246848d45444c7b033df3"}]},{"ProductId":"596340d3247946aaa109faeb065a7eab","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6284800","DateModified":"2025-05-15T09:58:25","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/CP066540.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066540.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066540.scexe"],"MD5Sum":"9232350f07813a8921c506a92e3e67c1","Name":"firmware-hdd-8b26d1ef02-HPD2-10.1.x86_64.rpm","Release":"2025-05-15T14:47:46","Revision":"J","SHA1Sum":"d37004d38354468b9263dce0279c47724ec4fd6d","SHA256Sum":"8a99f0b4279beefec881214319fedb42692bd9ee5d850493b1dee23076a6eaa2","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"CP041479.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:31:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support for RHEL 10</p>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"72438aa5f8824af8b15fb3db22e083d7"}]},{"ProductId":"8bcfdc333663490ba14bb0a7e2286062","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8266821","DateModified":"2025-04-29T12:28:30","FileList":["/CP066427_BUILD_5.data","/CP066427.vmcfg","/CP066427.vmexe64","/CP066427.vmfile","/CP066427_VMw.zip","/CP066427.xml","/payload.json","/CP066427_VMw.zip/index.xml","/CP066427_VMw.zip/vendor-index.xml","/CP066427_VMw.zip/metadata.zip","/CP066427_VMw.zip/vib20/CP066427/HPE_bootbank_CP066427_2.74.5-8.0.0.20613240.vib","/CP066427_VMw.zip/metadata.zip/vendor-index.xml","/CP066427_VMw.zip/metadata.zip/vmware.xml","/CP066427_VMw.zip/metadata.zip/vibs/CP066427-6270078346078038548.xml","/CP066427_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066427_2.74.5-8.0.0.20613240.xml"],"MD5Sum":"ce444f08c2c34afb2bfd540907312e0b","Name":"CP066427.zip","Release":"2025-04-29T12:25:22","Revision":"S","SHA1Sum":"5293dd881d79803e2aec4817f0277f83e88bc44d","SHA256Sum":"55a20e3699f7ff7635d509ce4c595de4a54a591b96f16938c0d848e77da98255","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74","VibList":[{"Name":"CP066427","Version":"2.74.5-8.0.0.20613240"}]}],"Installation":{"Command":"setup","CommandParams":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the Smart Component in a temporary directory.</li><li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li><li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li><li>Follow the directions given by the Smart Component.</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d, --discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e, --reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f, &nbsp;--force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g, --downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s, --silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p><p><strong>Remote Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"Lang":"ja","Value":"HPE D6020 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:11:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p>Added support of ESXi 9.0</p><p>Removed support of ESXi 7.0</p>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v266656/20-D6020-Gen10RN274T_ED18.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"21d47f962e094a4c94a38476a164a6b4"}]},{"ProductId":"4893b899f6404bf4b119e3e3a55be5b2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB012000JWDFD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB012000JWDFD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB012000JWDFD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"4425408","DateModified":"2025-01-11T12:18:16","FileList":["cp065093.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEAsssASFD4.rel"],"MD5Sum":"58cd50bc9590bbd753f8311fe2cd8396","Name":"cp065093.exe","Release":"2025-01-11T12:14:06","Revision":"C","SHA1Sum":"2695b64f1e78600c1aaa42cb4d96725c2cb96bec","SHA256Sum":"3df300db1c1a976aeb2e2bcb3d281e9eeb10291307abc4876e13f47d3f24079b","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000JWDFDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000JWDFD","TargetGUID":"4d2340a5-3042-3231-3030-304a57444644","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T11:58:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d7097370e49f4bb0859d4da747fe26b6"}]},{"ProductId":"f2f901fd357f4c6692fae66dcbbb15ed","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"16821851","DateModified":"2025-05-21T01:43:15","FileList":["payload.json","U44_3.60_05_16_2025.signed.flash","U44_3.60_05_16_2025.xml"],"MD5Sum":"7210baff7d2b3fecda9c38795ac219dc","Name":"U44_3.60_05_16_2025.fwpkg","Release":"2025-05-21T01:40:02","Revision":"","SHA1Sum":"7575f0a2f19a7f51c5c84aad927ce02a5253ab8b","SHA256Sum":"88ce3b7ddab8d0723eaca6901cb8886b39ab3f5f6a2d0767255e9f11575f1f50","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong>Service Pack for ProLiant</strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong>Service Pack for ProLiant</strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10(U44)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:45:15","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"58dfcf52b9a746a880d8a51db2b758f9"}]},{"ProductId":"ce7e63b5ed004965a0bc6af06ca584ef","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3656025","DateModified":"2025-07-27T12:46:36","FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/CP067521.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-21.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067521.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067521.scexe"],"MD5Sum":"3ddc5ff3fea9cdf3df758610b965f619","Name":"firmware-d6020-2.74-21.1.x86_64.rpm","Release":"2025-07-27T17:37:27","Revision":"U","SHA1Sum":"ca2cc45e846d1d3c86d83d846b3ed81b541d6d28","SHA256Sum":"0d3eafa1d85b6fe6038e7f407641f46a90cb5dd87ed97ddd10b1a3410f6878bc","Size":"3MB","TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"Installation":{"Command":"setup","CommandParams":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Linux Smart Component Installation Instructions:</strong></p><p><strong>Updating firmware with rpm installation:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p><ul><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>NOTES:</strong></p><p>OPTIONS for in band enclosure flash</p><table border=\"0\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td><td>Dumps discovery information in XML format to &lt;file&gt;</td></tr><tr><td>-e,&nbsp;--reflash</td><td>Flash even if the device is already up to date</td></tr><tr><td>-f,&nbsp; --force</td><td>Always flash applicable devices (same as -e -g)</td></tr><tr><td>-g,&nbsp;--downgrade</td><td>Flash if the device has a later firmware</td></tr><tr><td>-s,&nbsp;--silent</td><td>Do not display any text and no user interaction required</td></tr></tbody></table><p>&nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li><li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root (You must be root in order to apply the ROM update).</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li><li>Run the launch_sum.sh in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"Lang":"ja","Value":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T06:28:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>Rhel 7.8のサポートを追加しました </p></li><li><p>Rhel 8.2のサポートを追加しました </p></li><li><p>SLES15 SP2のサポートを追加しました</p></li></ul>","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of Rhel 7.8&nbsp;</p></li><li><p>Added support of Rhel 8.2&nbsp;</p></li><li><p>Added support of SLES15 SP2</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support ofRHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"<p><strong>このバージョンでは、以下の機能強化が追加されています。</strong></p><ul><li><p>RHEL 8.7のサポートを追加</p></li><li><p>RHEL 9.1のサポートを追加 </p></li><li><p>SLES15 SP4のサポートを追加</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p><ul><li><p>Added support of RHEL 8.7</p></li><li><p>Added support ofRHEL 9.1&nbsp;</p></li><li><p>Added support of SLES15 SP4</p></li></ul>","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v271808/20-D6020-Gen10RN274U_ED19.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8fbab50fa17e4b9282fec185dd4a95b7"}]},{"ProductId":"6ac4c1fb52734dc69d27fd9966ff92b4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.15.1.0</p>"},{"Lang":"ja","Value":"<p>この製品には、ドライバーバージョン1.15.1.0が含まれています。</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.15.1.0</p>"}],"Files":[{"Bytes":"216027","DateModified":"2024-01-12T03:34:38","FileList":["/cp058394.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/vendor-index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/vib20/ixgben/INT_bootbank_ixgben_1.18.2.0-1OEM.800.1.0.20613240.vib","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/vibs/ixgben--2922673856012024427.xml","/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240_22682220.zip/metadata.zip/bulletins/Intel-ixgben_1.18.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"36999d4326d7bd3718fd0291c12a2f09","Name":"cp058394.zip","Release":"2024-01-12T03:37:10","Revision":"","SHA1Sum":"cb691186c1b4272bd17bff8619736eb08873d8cc","SHA256Sum":"fdad7ac4c2b1f818e75b8af1201513c10c865e038d43796827120835a422003a","Size":"210KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2024.03.00","VibList":[{"Name":"ixgben","Version":"1.18.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixgben Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel ixgbenドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel ixgben Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-09-24T05:30:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product updated the copyright information and compatibility with firmware</p>","Fixes":"<p>This product fix an issue that TCP traffic on VMs might be interrupted if PF undergoes a reset.</p>","Lang":"en"},{"Enhancements":"<p>この製品は著作権情報とファームウェアの互換性をアップデートしました。</p>","Fixes":"<p>この製品は、PFがリセットされた場合にVM上のTCPトラフィックが中断される可能性がある問題を修正します。</p>","Lang":"ja"},{"Enhancements":"<p>This product updated the copyright information and compatibility with firmware</p>","Fixes":"<p>This product fix an issue that TCP traffic on VMs might be interrupted if PF undergoes a reset.</p>","Lang":"cn"}],"Version":"2023.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2024.03.00"}],"SWKeys":[{"Name":"Intel-ixgben:1.18.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.18.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b596876c814544fe8d905c525a92f4c4"}]},{"ProductId":"19810cc433a442df903276a4b0c34598","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"2342560","DateModified":"2025-03-25T06:20:18","FileList":["cp066445.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"c3beacd17e1f64364f723aaf0ca6d6c7","Name":"cp066445.exe","Release":"2025-03-25T06:06:42","Revision":"","SHA1Sum":"ec4cca0a8f8512ff01f8ae7f9fe03aecbb9c6735","SHA256Sum":"6018373dbf1e0bee1f3518d66e042fbdf21a4b0d4dc2f086128932c28f46d07c","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2019"},{"Lang":"cn","Value":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30117","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30040","Type":"pci","Ven":"15B3"},{"Dev":"101e","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30102","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101615b30047","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30116","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815b30052","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"101E","SubDev":"0007","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30007","Type":"pci","Ven":"15B3"},{"Dev":"101E","SubDev":"0012","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101e15b30012","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"49545129c4364737ade5f3abf92675b5"}]},{"ProductId":"990fcc25e986467fbdc6e3aae2e41a2c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK7"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK7"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK7"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK7"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK7"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK7"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK7"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALLGPK7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK7"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK7</p><p><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp;</strong>&nbsp; &nbsp;GPK6</p><p><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>GPK6</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for BSOD issue due to SRIS misdetection and FW Commit command via PCIe VDM (MCTP OVER PCIe) timed out.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"6284255","DateModified":"2025-05-14T06:10:29","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/CP066534.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/TACM6ALLGPK7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK7-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066534.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066534.scexe"],"MD5Sum":"0dbf1a5e869ed5085c72c56c0e4435c8","Name":"firmware-hdd-3815d4b024-GPK7-8.1.x86_64.rpm","Release":"2025-05-14T10:58:06","Revision":"H","SHA1Sum":"c53bc95ee852e09b08825fcc7d107971c8119117","SHA256Sum":"8ae13c2d05a56d6c31a825e00f19f246bb9e465642924c57c1a89eaf515820ec","Size":"5MB","TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK7"}],"Installation":{"Command":"CP043037.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong>追加情報：</strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p><strong>Additional Information:</strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"},{"Lang":"cn","Value":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6XRUL960G","TargetGUID":"002340a5-434b-364d-5852-554c39363047","Type":"nvme"},{"Id":"KCM6XRUL7T68","TargetGUID":"002340a5-434b-364d-5852-554c37543638","Type":"nvme"},{"Id":"KCM6XRUL1T92","TargetGUID":"002340a5-434b-364d-5852-554c31543932","Type":"nvme"},{"Id":"KCM6XVUL3T20","TargetGUID":"002340a5-434b-364d-5856-554c33543230","Type":"nvme"},{"Id":"KCM6XRUL3T84","TargetGUID":"002340a5-434b-364d-5852-554c33543834","Type":"nvme"},{"Id":"KCM6XVUL800G","TargetGUID":"002340a5-434b-364d-5856-554c38303047","Type":"nvme"},{"Id":"KCM6XVUL6T40","TargetGUID":"002340a5-434b-364d-5856-554c36543430","Type":"nvme"},{"Id":"KCM6XVUL1T60","TargetGUID":"002340a5-434b-364d-5856-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T10:10:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK7"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"GPK7"}],"SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5119c79be31943039be66699bbe8887f"}]},{"ProductId":"d4e991bf139c45c8a6f5a9b30e1a9d04","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34030474","DateModified":"2025-06-16T02:21:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/CP067585.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/U50_2.42_06_13_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.42_2025_06_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067585.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067585.scexe"],"MD5Sum":"9d7636730f5fd1f68f30a96f8d10422f","Name":"firmware-system-u50-2.42_2025_06_13-1.1.x86_64.rpm","Release":"2025-06-16T07:12:46","Revision":"","SHA1Sum":"839ab258d29135cac67982b9e72d439d78386352","SHA256Sum":"4100967021115f4a731c5dafb4d53404bd4780f5aacde670f471947bc28e7ac0","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T07:12:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5da107b072d149699819b76c0ae59878"}]},{"ProductId":"1e88e3b27b814bcdbc8dcf6390d324d1","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM4_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."},{"Lang":"ja","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM4 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"62652","DateModified":"2024-09-13T04:58:18","FileList":["HPE_UBM4_1.24_G.HPb","HPE_UBM4_1.24_G.xml","payload.json"],"MD5Sum":"028965ae0744c5bd9edba939bf775db9","Name":"HPE_UBM4_1.24_G.fwpkg","Release":"2024-09-13T04:53:37","Revision":"G","SHA1Sum":"f08bde255f56cfe95a4cb7cfb0c0c04754b9c24e","SHA256Sum":"21ad95f2ae46d3a5417a5bfa43832a676dde21e588070459bdfa5cf2778c62e1","Size":"61KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901504000000"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"},{"Lang":"ja","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"},{"Lang":"cn","Value":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901504000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-12T08:36:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>For Gen11 PR3 &amp; 2023 March MSB</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support Gen12 servers.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"UBM4PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"R11","Model":"HPE ProLiant RL300 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4e14138c4c714237bcc8bfb333533ccd"}]},{"ProductId":"6d5cd83fc05f4da0a652797154f87a4c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK5"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK5"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK5"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TACM6ALFGPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60およびKCM6FVUL3T20"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; GPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; GPK4</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"20938226","DateModified":"2025-03-06T06:17:03","FileList":["/CP065965_BUILD_4.data","/CP065965.vmexe64","/CP065965.vmfile","/CP065965_VMw.zip","/CP065965.xml","/payload.json","/CP065965_VMw.zip/index.xml","/CP065965_VMw.zip/vendor-index.xml","/CP065965_VMw.zip/metadata.zip","/CP065965_VMw.zip/vib20/CP065965/HPE_bootbank_CP065965_GPK5.4-1OEM.800.1.0.20613240.vib","/CP065965_VMw.zip/metadata.zip/vendor-index.xml","/CP065965_VMw.zip/metadata.zip/vmware.xml","/CP065965_VMw.zip/metadata.zip/vibs/CP065965--849390694784170641.xml","/CP065965_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065965_GPK5.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"5bff2a0a8a03d1ae2801afb6eb4e4426","Name":"CP065965.zip","Release":"2025-03-06T06:16:19","Revision":"C","SHA1Sum":"0f7924fd7221f5c843c0e1c3aa71a739d891f461","SHA256Sum":"9fe1918a598e915532f14e9d0a4674ca2a572f9b1b9d4079acc0782e740a0e4d","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK5","VibList":[{"Name":"CP065965","Version":"GPK5.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example:&nbsp; ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives"},{"Lang":"ja","Value":"オンラインNVMeSSDフラッシュコンポーネントfor VMware ESXi - KCM6FRUL1T92、KCM6FRUL3T84、KCM6FVUL1T60、およびKCM6FVUL3T20ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"KCM6FRUL1T92","TargetGUID":"002340a5-434b-364d-4652-554c31543932","Type":"nvme"},{"Id":"KCM6FRUL3T84","TargetGUID":"002340a5-434b-364d-4652-554c33543834","Type":"nvme"},{"Id":"KCM6FVUL3T20","TargetGUID":"002340a5-434b-364d-4656-554c33543230","Type":"nvme"},{"Id":"KCM6FVUL1T60","TargetGUID":"002340a5-434b-364d-4656-554c31543630","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:27:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"GPK5"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"GPK5"}],"SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"db3c3447749a47178b07d9d5b2df670b"}]},{"ProductId":"1d81dab4bd3149b19db9381601c1abce","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.33.41"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.33.41"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Linux x86_64 platform Only."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームのみで動作するHPE ProLiant Gen10サーバーシリーズのBroadcom NX1 Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen10 server series Broadcom NX1 Gigabit Ethernet NICs running under Linux x86_64 platform Only."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v20.33.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />HPE Ethernet 1Gb 4-port 331FLR Adapter<br />HPE Ethernet 1Gb 4-port 331T Adapter</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />HPE Ethernet 1Gb 2-port 332T Adapter</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table><p>For previous firmware versions prior to v20.19.51, please refer to the link :&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージには、下記のファームウェアバージョンを含むコンボイメージv20.33.41が含まれています：</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>ブートコードバージョン</strong></td><td><strong>PXEバージョン</strong></td><td><strong>NCSIバージョン</strong></td><td><strong>UEFIバージョン</strong></td></tr><tr><td>HPE Ethernet 1Gb 2ポート330iアダプター(22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 4ポート331iアダプター（22BE）<br />HPE Ethernet 1Gb 4ポート331FLRアダプター<br />HPE Ethernet 1Gb 4ポート331Tアダプター</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 2ポート332iアダプター（22E8）<br />HPE Ethernet 1Gb 2ポート332Tアダプター</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table><p>v20.19.51より前のファームウェアバージョンについては、次のリンクを参照してください。<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v20.33.41&nbsp;with the following firmware versions:</p><table border=\"1\" cellpadding=\"2\"><tbody><tr><td><strong>NIC</strong></td><td><strong>Boot Code Version</strong></td><td><strong>PXE Version</strong></td><td><strong>NCSI Version</strong></td><td><strong>UEFI Version</strong></td></tr><tr><td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td><td>2.10</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />HPE Ethernet 1Gb 4-port 331FLR Adapter<br />HPE Ethernet 1Gb 4-port 331T Adapter</td><td>1.60</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr><tr><td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />HPE Ethernet 1Gb 2-port 332T Adapter</td><td>1.43</td><td>21.6.4</td><td>1.5.61</td><td>21.6.90</td></tr></tbody></table><p>For previous firmware versions prior to v20.19.51, please refer to the link :&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c\">https://www.hpe.com/global/swpublishing/MTX-8670e218f6e948fe83fd64345c</a></p>"}],"Files":[{"Bytes":"5571075","DateModified":"2025-04-07T02:27:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/CP066648.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/CP066648.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.41.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066648.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066648.scexe"],"MD5Sum":"17f179e7c44afdcfdf0d7fe35c726d59","Name":"firmware-nic-bcm-2.41.0-1.1.x86_64.rpm","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"523db2deec0a532e03b424069f6b73ecc4d5d002","SHA256Sum":"7c6be5ada7fd03a6cc95966548ca6aadad0b125182218c10525b3f83aeb00806","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"2.41.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm</em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p><ul><li>ファームウェアrpmパッケージをインストールします。<br /><em>> rpm -ivh <rpm_filename>.rpm</em></li><li>ファイルを抽出する場所を確認します。<br /><em>> rpm -qlp <rpm_filename>.rpm</em></li><li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li></ul><p> </p><p><strong><em>追加情報：</em></strong></p><ul><li>詳細情報はCPxxxxxx.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCPxxxxxx.logに保存されます。</li><li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li><li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm</em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only."},{"Lang":"ja","Value":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティfor Linux x86_64（HPE ProLiant Gen10サーバーシリーズ専用）。"},{"Lang":"cn","Value":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-18T03:34:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアのアップデート後にMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes where MBA configuration reset to defaults after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、ファームウェアをアップデートした後に、BCM5719 4ポートアダプターのポート3および4でMBA構成がデフォルトにリセットされる問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where MBA configuration reset to defaults on port 3 and 4 for BCM5719&nbsp;4-port adapters after updating firmware.</p>","Lang":"cn"}],"Version":"2.41.0"}],"SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"dbaad443da764ee7a12d4c995ca78211"}]},{"ProductId":"98a183458fbc454a86f635797ce90db5","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"QLogic driver for VMware vSphere 9.0"},{"Lang":"ja","Value":"QLogicドライバーfor VMware vSphere 9.0"},{"Lang":"cn","Value":"QLogic driver for VMware vSphere 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"717832","DateModified":"2025-04-09T05:14:56","FileList":["/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip","/cp066316.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.5.85.0-1OEM.900.0.24580437.vib","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/vibs/qlnativefc--7359688079739690666.xml","/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437_24658432.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.5.85.0-1OEM.900.0.24580437.xml"],"MD5Sum":"8f6d0d53ff8ed5d2c8a88b1221f7405a","Name":"cp066316.zip","Release":"2025-04-09T05:13:54","Revision":"","SHA1Sum":"6dedf80bd3c5dc4ef1c6eceb3a1f125a61bfde5f","SHA256Sum":"b7b7a8a31d407600a9f149486ddfeaed5264e451726819880ea58d09d50c42d4","Size":"701KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"qlnativefc","Version":"5.5.85.0-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":380,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"cn","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"},{"Lang":"ja","Value":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0"},{"Lang":"ja","Value":"HPE QLogicファイバーチャネルドライバーコンポーネントfor VMware vSphere 9.0"},{"Lang":"cn","Value":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-19T14:54:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン5.4.83.1<br />このドライバーは、VMware ESXi 9.0でのみサポートされています。</p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.4.83.1<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Driver version 5.5.85.0<br />This driver is only supported on VMware ESXi 9.0</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"qlnativefc:5.5.85.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.5.85.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"b36a633ff667434295a5dcb82e072da5"}]},{"ProductId":"955cffa0d4fe4b76923c0ea7afeca0bf","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA4_FH_4p71_PLDMoMCTP_8002003E.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>8002003E</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター</td><td>8002003E</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td><td>8002003E</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10524703","DateModified":"2025-03-28T07:21:59","FileList":["HPE_E810_XXVDA4_FH_4p71_PLDMoMCTP_8002003E.HPb","HPE_E810_XXVDA4_FH_4p71_PLDMoMCTP_8002003E.xml","payload.json"],"MD5Sum":"84aa059da329fef2c558dac726ced4bc","Name":"HPE_E810_XXVDA4_FH_4p71_PLDMoMCTP_8002003E.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"4b89906425f044002d2888a0f9efbec5c9cc225d","SHA256Sum":"2444bd1fd8a9f92da69fa43bd2e4954ef6fdeef4ce6aa6ed21b0bdac64f3900f","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター"},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:38:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"d8ac3cc8e7004f38a04514ae385d41d7"}]},{"ProductId":"5c10ef42611f4cada08e038ec64fbce6","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.65.21"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.21_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.65.21"}]},"MinimumActiveVersion":"8.55.12","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.65.21.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.65.7.0, and UEFI: 6.1.8.2.</p>"}],"Files":[{"Bytes":"1951754","DateModified":"2024-12-11T01:46:22","FileList":["payload.json","ql_ah_mbi_open_8.65.21_pldm.HPb","ql_ah_mbi_open_8.65.21_pldm.xml"],"MD5Sum":"013a07faf6995d0bc4fe102a890f8937","Name":"ql_ah_mbi_open_8.65.21_pldm.fwpkg","Release":"2024-12-11T01:43:39","Revision":"","SHA1Sum":"4a5982651c781b8db0fb1829ec01a4bf335e0bb0","SHA256Sum":"93e258a0ddbb7ec12a6ed335ffe61e1ea0ca197c5aa212737b436c0dd2f94f0a","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-80f010770078"],"TypeOfChange":"1","Version":"8.65.21"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Firmware Package for Arrowhead adapters"},{"Lang":"ja","Value":"Arrowheadアダプター用Marvell FastLinQファームウェアパッケージ"},{"Lang":"cn","Value":"Marvell FastLinQ Firmware Package for Arrowhead adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:03:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"8.65.14"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.65.21"}],"SWKeys":[{"Name":"MARVELL_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"bc48d0c6a7274ea890d1070742ae9a44"}]},{"ProductId":"be910528f863487899cf62f353be4a46","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD3"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD3"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB006000JYDNF, MB008000JYDPC and MB010000JYDNH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul><p><strong>Known Issues:</strong></p><ul><li>For Drive Model &quot;MB010000JYDNH&quot; of 10TB,&nbsp;initial release FW is HPD3 and there is no downgrade support for this model to lower version HPD2.</li></ul>"}],"Files":[{"Bytes":"20903280","DateModified":"2025-03-06T12:47:58","FileList":["/CP065960_BUILD_3.data","/CP065960.vmexe64","/CP065960.vmfile","/CP065960_VMw.zip","/CP065960.xml","/payload.json","/CP065960_VMw.zip/index.xml","/CP065960_VMw.zip/vendor-index.xml","/CP065960_VMw.zip/metadata.zip","/CP065960_VMw.zip/vib20/CP065960/HPE_bootbank_CP065960_HPD3.3-1OEM.800.1.0.20613240.vib","/CP065960_VMw.zip/metadata.zip/vendor-index.xml","/CP065960_VMw.zip/metadata.zip/vmware.xml","/CP065960_VMw.zip/metadata.zip/vibs/CP065960-8029159976628610106.xml","/CP065960_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065960_HPD3.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"86c59529c78813b247cf6c3b30621e95","Name":"CP065960.zip","Release":"2025-03-06T12:47:14","Revision":"B","SHA1Sum":"6c0b2a98dae386d5695297ea9584a47735e4e0f1","SHA256Sum":"940d95a5b4fdd91d94e4132b44498c1b62ac0d6440d6bb4887fe60d72d4e2e73","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065960","Version":"HPD3.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JYDNF、MB008000JYDPC、およびMB010000JYDNHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JYDNF","TargetGUID":"4d2340a5-3042-3630-3030-304a59444e46","Type":"sas"},{"Id":"MB008000JYDPC","TargetGUID":"4d2340a5-3042-3830-3030-304a59445043","Type":"sas"},{"Id":"MB010000JYDNH","TargetGUID":"4d2340a5-3042-3031-3030-304a59444e48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:49:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ドライブがアサートを防ぐためにRequest Senseの前にR/Wコマンドを選択して実行する原因となった、メディアキャッシュクリーニングの中止処理のロジックバグを修正しました。</li><li>その他のログ機能とFW機能強化を追加します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.</li><li>Adding other&nbsp;logging and FW enhancements.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1985144b7a1a4fe793768a830390a68d"}]},{"ProductId":"b6cb1e645c374b3e92e6a0688121990e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added Support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18078774","DateModified":"2025-03-07T11:19:22","FileList":["/CP065966_BUILD_2.data","/CP065966.vmexe64","/CP065966.vmfile","/CP065966_VMw.zip","/CP065966.xml","/payload.json","/CP065966_VMw.zip/index.xml","/CP065966_VMw.zip/vendor-index.xml","/CP065966_VMw.zip/metadata.zip","/CP065966_VMw.zip/vib20/CP065966/HPE_bootbank_CP065966_HPD5.2-1OEM.800.1.0.20613240.vib","/CP065966_VMw.zip/metadata.zip/vendor-index.xml","/CP065966_VMw.zip/metadata.zip/vmware.xml","/CP065966_VMw.zip/metadata.zip/vibs/CP065966-8362333243778612089.xml","/CP065966_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065966_HPD5.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c33bd5dae687a90ecf8290d6fb17012f","Name":"CP065966.zip","Release":"2025-03-07T11:18:28","Revision":"E","SHA1Sum":"88a06961aabdc0d5cdd033b64521667be2f94db7","SHA256Sum":"21a06255a005a00c051ff12699b3a991c80d3afdcca183480dc9ecc234ae7ccd","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065966","Version":"HPD5.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041563.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EG001200JWJNK","TargetGUID":"452340a5-3047-3130-3230-304a574a4e4b","Type":"sas"},{"Id":"EG000600JWJNH","TargetGUID":"452340a5-3047-3030-3630-304a574a4e48","Type":"sas"},{"Id":"EG000300JWSJP","TargetGUID":"452340a5-3047-3030-3330-304a57534a50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:28:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added Support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1943010e21304beeac6d93db0b65cff5"}]},{"ProductId":"799e6d2dd6574724a67dc3ea392d2873","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"Lang":"cn","Value":"可升级 HPE ProLiant Gen9 扩展卡上机柜固件的补充更新/在线 ROM Flash 智能组件"},{"Lang":"ja","Value":"HPE ProLiant Gen9エキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5420336","DateModified":"2025-05-14T07:02:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/CP066643.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066643.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066643.scexe"],"MD5Sum":"e54dd49b8731fd018867e75104d8ada5","Name":"firmware-smartarray-1f19a4a64d-5.15-5.1.x86_64.rpm","Release":"2025-05-14T11:47:05","Revision":"E","SHA1Sum":"afbf4ce6b2a727407647b5685f318fc48db55651","SHA256Sum":"3d74fab5961435f55e43fba45a6dbbf19b30081ad98a8ed68a60e23f5beeb7e6","Size":"5MB","TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"Installation":{"Command":"CP066643.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the&nbsp;USB Key Utility for Windows.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the&nbsp;USB Key Utility for Windows.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1f19a4a64d-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the&nbsp;USB Key Utility for Windows.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"Lang":"cn","Value":"Linux (x64)版补充更新/在线ROM刷新组件 – 适用于HPE智能阵列控制器和HPE HBA控制器的HPE 12Gb/s SAS扩展器固件"},{"Lang":"ja","Value":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE 12 Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-02T02:26:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"5.15"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.15"}],"SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5aa7ee386fcc462f98821054e3dbf958"}]},{"ProductId":"58259b45dec7469580dfbddb76171768","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf-kmp-default) to (igb-ixgbevf-default). Now we revert this change from (ixgbevf-kmp-default) to (<strong>hp</strong>-ixgbevf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbevf-kmp-default and ixgbevf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbevf-kmp-default and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>  このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf-kmp-default）から（igb-ixgbevf-default）に変更されました。この変更を（ixgbevf-kmp-default）から（<strong>hp</strong>-ixgbevf-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-ixgbevf-kmp-defaultとixgbevf-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e ixgbevf-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf-kmp-default) to (igb-ixgbevf-default). Now we revert this change from (ixgbevf-kmp-default) to (<strong>hp</strong>-ixgbevf-kmp-default).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-ixgbevf-kmp-default and ixgbevf-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install ixgbevf-kmp-default-4.18.7_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e ixgbevf-kmp-default and then install the updated RPM.</p>"}],"Files":[{"Bytes":"81888","DateModified":"2025-04-01T08:48:06","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"MD5Sum":"e7ca7f66645dadba1160d2987afae06a","Name":"hp-ixgbevf-kmp-default-4.21.25_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T08:42:05","Revision":"","SHA1Sum":"f37e0753d2d8266b95e864efc4f39b00208bbbb7","SHA256Sum":"61a85eb5b2eb32b76fd7d578951bab80300cc38c60634866e4d86970a1c14841","Size":"79KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"4.21.25-1"},{"Bytes":"73221","DateModified":"2025-04-01T08:52:21","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/hp-ixgbevf","./lib/modules/5.14.21-150500.53-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"MD5Sum":"9f3c0f05504d6b65d037813ff41e3d8a","Name":"hp-ixgbevf-kmp-default-4.21.25_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T08:42:05","Revision":"","SHA1Sum":"714099a9262801eccde570d2a2999eded2d2960e","SHA256Sum":"881584af18b60b4d51757c4c8631a690e72e1095341ec575f9880e88d37c280c","Size":"71KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"4.21.25-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c192d","Type":"pci","Ven":"8086"},{"Dev":"1515","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1515103c211a","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:05:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"","Lang":"cn"}],"Version":"4.20.5-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"4.21.25-1"}],"SWKeys":[{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"85763af19287402f8cd33fde1111c9e1"}]},{"ProductId":"0b3bbfed90454334ba3331c2f9efa2ea","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN&nbsp;Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：<br />     </strong>オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />     </strong>HPD5</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD4</p><p><strong>前のファームウェアバージョン：</strong><br />     HPD4<br /><br /><strong>ファームウェアの関連性：  </strong></p><p>     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />      なし</p>"}],"Files":[{"Bytes":"18459509","DateModified":"2025-03-06T11:19:42","FileList":["/CP065944_BUILD_2.data","/CP065944.vmexe64","/CP065944.vmfile","/CP065944_VMw.zip","/CP065944.xml","/payload.json","/CP065944_VMw.zip/index.xml","/CP065944_VMw.zip/vendor-index.xml","/CP065944_VMw.zip/metadata.zip","/CP065944_VMw.zip/vib20/CP065944/HPE_bootbank_CP065944_HPD5.2-1OEM.800.1.0.20613240.vib","/CP065944_VMw.zip/metadata.zip/vendor-index.xml","/CP065944_VMw.zip/metadata.zip/vmware.xml","/CP065944_VMw.zip/metadata.zip/vibs/CP065944--8710370949825720746.xml","/CP065944_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065944_HPD5.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b6b34bc0fd854fe2766329a81018aaa9","Name":"CP065944.zip","Release":"2025-03-06T11:18:57","Revision":"C","SHA1Sum":"b1d48ce6b30dcaaff3187f21f9fb9d5b62bb100c","SHA256Sum":"e9b4ab42c30a066b3a028b5e64ead38480356eb0466aa8e70341734cabeb70d3","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP065944","Version":"HPD5.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043253.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:28:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8c3ce5786422481ca1e335852104a165"}]},{"ProductId":"ab42380273374a988dbcb1a25432ed96","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p style=\"margin-left:40px\"><strong>HDR / 200GbEケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR対NDRスイッチ相互運用ケーブル：</strong></p><ul><li>HDR    P45733-B21    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10mスプリッターアクティブ光ケーブル</li><li>HDR    P45733-B22    HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30mスプリッターアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p style=\"margin-left:40px\"><strong>HDR / 200GbE cables:</strong></p><ul style=\"margin-left:40px\"><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p style=\"margin-left:40px\"><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul style=\"margin-left:40px\"><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><p><strong>Validated and Supported&nbsp;HDR to NDR Switch interoperability cables:</strong></p><ul><li>HDR&nbsp; &nbsp; P45733-B21&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 10m Splitter Active Optical Cable</li><li>HDR&nbsp; &nbsp; P45733-B22&nbsp; &nbsp; HPE InfiniBand HDR/Ethernet OSFP to 2xQSFP56 30m Splitter Active Optical Cable</li></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6264512","DateModified":"2025-06-16T05:53:15","FileList":["20_43_2566-MCX653106A-HDA_HPE_Ax.pldm.signed","20_43_2566-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"9d03ceb1c58c7f41632baffb004c83e2","Name":"20_43_2566-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:51:05","Revision":"","SHA1Sum":"4bdb7e74cbed60589714959f009533a204c3a192","SHA256Sum":"171f38d4550b025225014ef82a7eb0c9f6632dcc3b2b09770a3741333113b1a8","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900345"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T06:37:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"c1f85c93b47b4286a27f78fea1b39e1c"}]},{"ProductId":"ff5a3639b5c744a8ac2e4611ce9482ea","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11904708","DateModified":"2025-05-14T04:35:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/CP067199.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/U32_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067199.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067199.scexe"],"MD5Sum":"769cfaf1cd1dd3a3065beb2afc9e3378","Name":"firmware-system-u32-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-14T09:24:33","Revision":"B","SHA1Sum":"e8237cc0736266b7cd14bde3cd6442cc146f010a","SHA256Sum":"fa67fdef14c0e24ec57b29ee8497e1b75d0edd06af60a967d53f413bcc53593d","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T09:23:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9d74ccf59c994c46acb41b5fc577a603"}]},{"ProductId":"6ca4dd262131408db10af90451555128","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_2566-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter  : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"ja","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter  : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"cn","Value":"NVIDIA HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter  : HPE part numbers P23666-B21 and P23666-H21"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"},{"Lang":"ja","Value":"<p><strong>検証済みおよびサポートされるHDRケーブル：</strong></p><ul><li>P28169-B21    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P28169-B22    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P28169-B23    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P28169-B24    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P28169-B25    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P28169-B26    HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>検証済みおよびサポートされるHDR / 200GbEケーブル：</strong></p><p> </p><p><strong>HDR / 200GbEケーブル：</strong></p><ul><li>P06149-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>P06149-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5mダイレクトアタッチ銅線ケーブル</li><li>P06149-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>P06153-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3mアクティブ光ケーブル</li><li>P06153-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>P06153-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>P06153-B24    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>P06153-B25    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20mアクティブ光ケーブル</li><li>P06153-B26    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30mアクティブ光ケーブル</li></ul><p><strong>2xHDR100 / 2x100GbEスプリッターケーブル：</strong></p><ul><li>P06248-B21    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B22    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P06248-B23    HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2mスプリッターダイレクトアタッチ銅線ケーブル</li><li>P26659-B21    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AOスプリッターケーブル</li><li>P26659-B22    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AOスプリッターケーブル</li><li>P26659-B23    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AOスプリッターケーブル</li><li>P26659-B24    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AOスプリッターケーブル</li><li>P26659-B25    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AOスプリッターケーブル</li><li>P26659-B26    HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AOスプリッターケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされるEDRケーブル：</strong></p><ul><li>EDR    834973-B22    HPE 1M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B24    HPE 2M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B25    HPE 3M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B21    HPE 0.5M IB EDR QSFP銅ケーブル</li><li>EDR    834973-B23    HPE 1.5M IB EDR QSFP銅ケーブル</li><li>EDR    834972-B24    HPE 10M IB EDR QSFP光ケーブル</li><li>EDR    834972-B21    HPE 3M IB EDR QSFP光ケーブル</li><li>EDR    834972-B22    HPE 5M IB EDR QSFP光ケーブル</li><li>EDR    834972-B23    HPE 7M IB EDR QSFP光ケーブル</li><li>EDR    834972-B25    HPE 12M IB EDR QSFP光ケーブル</li><li>EDR    834972-B26    HPE 15M IB EDR QSFP光ケーブル</li><li>EDR    834972-B27    HPE 20M IB EDR QSFP光ケーブル</li><li>EDR    834972-B28    HPE 30M IB EDR QSFP光ケーブル</li></ul><ul></ul><p><strong>検証済みおよびサポートされる10GbEケーブル：</strong></p><ul><li>10GbE    455883-B21    HPE BladeSystem c-Class 10Gb SFP+ SRトランシーバー</li><li>10GbE    455886-B21    HPE BladeSystem c-Class 10Gb SFP+ LRトランシーバー</li><li>10GbE    537963-B21    HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    487655-B21     HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3mダイレクトアタッチ銅線ケーブル</li><li>1GbE/10GbE    655874-B21    HPE QSFP/SFP+アダプターキット</li><li>10GbE    813874-B21        HPE 10GBase-T SFP+トランシーバー </li><li>10GbE    838327-B21        HPE Synergyデュアル10GBASE-T QSFP+ 30m RJ45トランシーバー</li></ul><p><strong>検証済みおよびサポートされる25GbEケーブル：</strong></p><ul><li>25GbE    845970-B21    HPE QSFP 28 to SFP28アダプター        </li><li>25GbE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC        </li><li>25GbE    845420-B21    HPE QSFP28 to 4x25G SFP28 7m AOC        </li><li>25GbE    845424-B21    HPE QSFP28 to 4x25Gb SFP28 15m AOC        </li><li>25GbE    844483-B21    HPE 25Gb SFP28 to SFP28 7m AOC        </li><li>25GbE    845396-B21    HPE 25Gb SFP28 to SFP28 15m AOC         </li><li>25GbE    845398-B21    HPE 25Gb SFP28 SR 100mトランシーバー   </li></ul><p><strong>検証済みおよびサポートされる40GbEケーブル：</strong></p><ul><li>40GbE    720211-B21    HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15mアクティブ光ケーブル</li><li>40GbE    721076-B21    HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt  </li><li>40GbE    720187-B21    HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100mトランシーバー</li><li>40GbE    720193-B21    HPE BladeSystem c-Class QSFP+ to SFP+アダプター</li><li>40GbE    817040-B21    HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+トランシーバー</li><li>40GbE    720199-B22    HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m ダイレクトアタッチ銅線ケーブル</li><li>40GbE    720202-B23    HPE HP BLC 40G QSFP+ QSFP+ 5M DACケーブル</li><li>40GbE    721064-B21    HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3mダイレクトアタッチ銅スプリッターケーブル</li><li>40GbE    841716-B21    HPE 40Gb QSFP+双方向トランシーバー</li><li>40GbE     JH232A         HPE X142 40G QSFP+ LC LR4 SMトランシーバー</li></ul><p><strong>検証済みおよびサポートされる100GbEケーブル：</strong></p><ul><li>100GBE    845408-B21    HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE    845416-B21    HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE    845406-B21    HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE    845972-B21    HPE 100Gb QSFP28双方向XCVR</li><li>100GBE    845410-B21    HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE    845412-B21    HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE    845414-B21    HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE    Q8J73A        HPE Mシリーズ100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE    Q2F19A        HPE Mシリーズ100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>検証済みおよびサポートされる200GbEケーブル：</strong></p><ul><li>200GBE  R5Z76A    HPE 200Gb QSFP56 to QSFP56 0.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z77A    HPE 200Gb QSFP56 to QSFP56 1mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z78A    HPE 200Gb QSFP56 to QSFP56 2mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z79A    HPE 200Gb QSFP56 to QSFP56 2.5mダイレクトアタッチ銅線ケーブル</li><li>200GBE  R5Z80A    HPE 200Gb QSFP56 to QSFP56 5mアクティブ光ケーブル</li><li>200GBE  R5Z81A    HPE 200Gb QSFP56 to QSFP56 10mアクティブ光ケーブル</li><li>200GBE  R5Z82A    HPE 200Gb QSFP56 to QSFP56 15mアクティブ光ケーブル</li><li>200GBE  R5Z83A    HPE 200Gb QSFP56 MPO SR4 100mトランシーバー</li><li>200GBE    R6F24A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 3mアクティブ光ケーブル</li><li>200GBE    R6F25A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 5mアクティブ光ケーブル</li><li>200GBE    R6F26A    HPE 200Gb QSFP56 to 2x100Gb QSFP56 15mアクティブ光ケーブル</li></ul><p>注記：このセクションに記載されているのは、HPE部品番号の付いたケーブルだけです。サポートされているケーブルの完全なリストについては、ファームウェアダウンロードにバンドルされているリリースノートを参照してください。</p>"},{"Lang":"cn","Value":"<p><strong>Validated and Supported HDR cables:</strong></p><ul><li>P28169-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P28169-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P28169-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P28169-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P28169-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P28169-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>Validated and Supported HDR / 200GbE cables:</strong></p><p>&nbsp;</p><p><strong>HDR / 200GbE cables:</strong></p><ul><li>P06149-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>P06149-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>P06149-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 1.5m Direct Attach Copper Cable</li><li>P06149-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>P06153-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 3m Active Optical Cable</li><li>P06153-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>P06153-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>P06153-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>P06153-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 20m Active Optical Cable</li><li>P06153-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to QSFP56 30m Active Optical Cable</li></ul><p><strong>2xHDR100 / 2x100GbE splitter cables:</strong></p><ul><li>P06248-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1m Splitter Direct Attach Copper Cable</li><li>P06248-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 1.5m Splitter Direct Attach Copper Cable</li><li>P06248-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR/Ethernet 200Gb QSFP56 to 2xQSFP56 2m Splitter Direct Attach Copper Cable</li><li>P26659-B21&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 3m AO Splitter Cable</li><li>P26659-B22&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 5m AO Splitter Cable</li><li>P26659-B23&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 10m AO Splitter Cable</li><li>P26659-B24&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 15m AO Splitter Cable</li><li>P26659-B25&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 20m AO Splitter Cable</li><li>P26659-B26&nbsp;&nbsp; &nbsp;HPE InfiniBand HDR 200Gb to HDR100/Ethernet 2x100Gb QSFP56 to 2xQSFP56 30m AO Splitter Cable</li></ul><ul></ul><p><strong>Validated and Supported EDR Cables:</strong></p><ul><li>EDR&nbsp;&nbsp;&nbsp; 834973-B22&nbsp;&nbsp;&nbsp; HPE 1M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B24&nbsp;&nbsp;&nbsp; HPE 2M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B25&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B21&nbsp;&nbsp;&nbsp; HPE 0.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834973-B23&nbsp;&nbsp;&nbsp; HPE 1.5M IB EDR QSFP Copper Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B24&nbsp;&nbsp;&nbsp; HPE 10M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B21&nbsp;&nbsp;&nbsp; HPE 3M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B22&nbsp;&nbsp;&nbsp; HPE 5M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B23&nbsp;&nbsp;&nbsp; HPE 7M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B25&nbsp;&nbsp;&nbsp; HPE 12M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B26&nbsp;&nbsp;&nbsp; HPE 15M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B27&nbsp;&nbsp;&nbsp; HPE 20M IB EDR QSFP Optical Cable</li><li>EDR&nbsp;&nbsp;&nbsp; 834972-B28&nbsp;&nbsp;&nbsp; HPE 30M IB EDR QSFP Optical Cable</li></ul><ul></ul><p><strong>Validated and Supported 10GbE Cables:</strong></p><ul><li>10GbE&nbsp;&nbsp; &nbsp;455883-B21 &nbsp;&nbsp; HPE BladeSystem c-Class 10Gb SFP+ SR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;455886-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10Gb SFP+ LR Transceiver</li><li>10GbE&nbsp;&nbsp; &nbsp;537963-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 5m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;487655-B21 &nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 10GbE SFP+ to SFP+ 3m Direct Attach Copper Cable</li><li>1GbE/10GbE&nbsp;&nbsp; &nbsp;655874-B21&nbsp;&nbsp; &nbsp;HPE QSFP/SFP+ Adaptor Kit</li><li>10GbE&nbsp;&nbsp; &nbsp;813874-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE 10GBase-T SFP+ Transceiver&nbsp;</li><li>10GbE&nbsp;&nbsp; &nbsp;838327-B21&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Synergy Dual 10GBASE-T QSFP+ 30m RJ45 Transceiver</li></ul><p><strong>Validated and Supported 25GbE Cables:</strong></p><ul><li>25GbE&nbsp;&nbsp; &nbsp;845970-B21&nbsp; &nbsp; HPE QSFP 28 to SFP28 Adaptor&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845420-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25G SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845424-B21&nbsp;&nbsp; &nbsp;HPE QSFP28 to 4x25Gb SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;844483-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 7m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845396-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 to SFP28 15m AOC&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;</li><li>25GbE&nbsp;&nbsp; &nbsp;845398-B21&nbsp;&nbsp; &nbsp;HPE 25Gb SFP28 SR 100m Transceiver&nbsp; &nbsp;</li></ul><p><strong>Validated and Supported 40GbE Cables:</strong></p><ul><li>40GbE&nbsp;&nbsp; &nbsp;720211-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40G QSFP+ to QSFP+ 15m Active Optical Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721076-B21&nbsp;&nbsp; &nbsp;HP BLc QSFP+ to 4x10G SFP+ AOC 15m Opt &nbsp;</li><li>40GbE&nbsp;&nbsp; &nbsp;720187-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720193-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c-Class QSFP+ to SFP+ Adapter</li><li>40GbE&nbsp;&nbsp; &nbsp;817040-B21&nbsp;&nbsp; &nbsp;HPE Synergy 40GbE/4x10GbE/4x8Gb FC QSFP+ Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp;720199-B22&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to QSFP+ 3m Direct Attach Copper Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;720202-B23&nbsp;&nbsp; &nbsp;HPE HP BLC 40G QSFP+ QSFP+ 5M DAC Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;721064-B21&nbsp;&nbsp; &nbsp;HPE BladeSystem c‑Class 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable</li><li>40GbE&nbsp;&nbsp; &nbsp;841716-B21&nbsp;&nbsp; &nbsp;HPE 40Gb QSFP+ Bidirectional Transceiver</li><li>40GbE&nbsp;&nbsp; &nbsp; JH232A &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE X142 40G QSFP+ LC LR4 SM Transceiver</li></ul><p><strong>Validated and Supported 100GbE Cables:</strong></p><ul><li>100GBE&nbsp;&nbsp; &nbsp;845408-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 5m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845416-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to 4x25Gb SFP28 3m DAC</li><li>100GbE&nbsp;&nbsp; &nbsp;845406-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 3m DAC</li><li>100GBE&nbsp;&nbsp; &nbsp;845972-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 Bidirectional XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;845410-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 7m AOC</li><li>100GbE&nbsp;&nbsp; &nbsp;845412-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 10m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;845414-B21&nbsp;&nbsp; &nbsp;HPE 100Gb QSFP28 to QSFP28 15m AOC</li><li>100GBE&nbsp;&nbsp; &nbsp;Q8J73A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE Mseries 100GbE QSFP28 PSM4 500m XCVR</li><li>100GBE&nbsp;&nbsp; &nbsp;Q2F19A&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;HPE M-series 100GbE QSFP28 SR4 100m XCVR</li></ul><p><strong>Validated and Supported 200GbE Cables:</strong></p><ul><li>200GBE &nbsp;R5Z76A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 0.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z77A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 1m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z78A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z79A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 2.5m Direct Attach Copper Cable</li><li>200GBE &nbsp;R5Z80A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 5m Active Optical Cable</li><li>200GBE &nbsp;R5Z81A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 10m Active Optical Cable</li><li>200GBE &nbsp;R5Z82A &nbsp; &nbsp;HPE 200Gb QSFP56 to QSFP56 15m Active Optical Cable</li><li>200GBE &nbsp;R5Z83A &nbsp; &nbsp;HPE 200Gb QSFP56 MPO SR4 100m Transceiver</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F24A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 3m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F25A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 5m Active Optical Cable</li><li>200GBE&nbsp;&nbsp; &nbsp;R6F26A&nbsp;&nbsp; &nbsp;HPE 200Gb QSFP56 to 2x100Gb QSFP56 15m Active Optical Cable</li></ul><p>Note: Only cables with HPE Part Numbers are listed in this section. Refer the Release Notes document bundled with the firmware download for a complete list of supported cables.</p>"}],"Files":[{"Bytes":"6264630","DateModified":"2025-06-16T05:34:18","FileList":["20_43_2566-MCX653106A-ECA_HPE_Ax.pldm.signed","20_43_2566-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"MD5Sum":"b89caf76e83b5541b59d3fc37e515d09","Name":"20_43_2566-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","Release":"2025-06-16T05:32:31","Revision":"","SHA1Sum":"fa85232965990d01874ef29fbc7dbf270d3c966d","SHA256Sum":"11ec608a2d3a698a505fb24975b8f71c4bb4e7119d69effdb978d891a5f1d133","Size":"5MB","TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"TypeOfChange":"1","Version":"20.43.2566"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"margin-left:40px\"><li><p><strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208&tab=revisionHistory\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"margin-left:40px\"><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208&amp;tab=revisionHistory\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"ja","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21"},{"Lang":"cn","Value":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"32000"},"SupportedDevices":[{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-03T06:17:42","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"20.43.2026"},{"ReleaseNotes":[{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"20.43.2566"}],"SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"bac9b9b7601b44fe97018729b37ae673"}]},{"ProductId":"614a0c688deb4def90dafbe34fab64bb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE SmartアレイおよびSmart RAIDコントローラードライバーコンポーネントfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 8.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"404226","DateModified":"2024-12-13T04:39:36","FileList":["/cp062918.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip","/MIS_bootbank_smartpqi_80.4704.0.108-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/index.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/vendor-index.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/metadata.zip","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/vib20/smartpqi/MIS_bootbank_smartpqi_80.4704.0.108-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/metadata.zip/vibs/smartpqi-8441234935956192661.xml","/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240_24402795.zip/metadata.zip/bulletins/Microchip-smartpqi_80.4704.0.108-1OEM.800.1.0.20613240.xml"],"MD5Sum":"52a840efe81529d3166dc3deec82d121","Name":"cp062918.zip","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"c25aa9a9973bece20ec78eae1ab16fa4726c85ef","SHA256Sum":"babebcb29a0e7aa84aa23fda97ad43f446cb068cd1be5a47fec0dd8676b23d0a","Size":"394KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2025.02.01","VibList":[{"Name":"smartpqi","Version":"80.4704.0.108-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p><p><strong>リモートオンライン：</strong></p><ul><li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li><li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li><li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li><li> CD /hp/swpackagesおよび./hpsum</li><li> 次へボタンを選択します。</li><li> シングルターゲットの追加をクリックします。</li><li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li><li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li> Smart Update Managerの指示に従ってアップデートを行います。</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p><ul><li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li><li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li></ul><p><br /> </p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p><p><strong>Remote Online: </strong></p><ul><li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li><li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li><li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li><li>&nbsp;CD /hp/swpackages and ./hpsum</li><li>&nbsp;Select the next button</li><li>&nbsp;Click Add Single Target</li><li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li><li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li><li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li><li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li><li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li></ul><p><br />&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component)."},{"Lang":"ja","Value":"HPE ProLiant Gen10 SmartアレイおよびGen10 PlusおよびGen11 Smart RAIDコントローラードライバーfor VMware vSphere 8.0 (ドライバーコンポーネント)"},{"Lang":"cn","Value":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component)."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:22:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Improve the tolerance of error handling.</li><li>Enhancement of DMA engine attributes to prevent PSOD.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>エラー処理の許容度を向上します。</li><li>PSODを防ぐためのDMAエンジン属性の強化。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Improve the tolerance of error handling.</li><li>Enhancement of DMA engine attributes to prevent PSOD.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.02.01"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Improve the tolerance of error handling.</li><li>Enhancement of DMA engine attributes to prevent PSOD.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>エラー処理の許容度を向上します。</li><li>PSODを防ぐためのDMAエンジン属性の強化。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Improve the tolerance of error handling.</li><li>Enhancement of DMA engine attributes to prevent PSOD.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"2025.02.01"}],"SWKeys":[{"Name":"Microchip-smartpqi:80.4704.0.108-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:80.4704.0.108-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"af871489e60b470ea50404d59023eba9"}]},{"ProductId":"14160fbfa3db428fb3e9bea4f7d651a7","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175014e4159a","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180214e4159a","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180514e4159a","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-175014e4159b","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180214e4159b","Version":"233.1.135.7"},{"DeviceName":"Broadcom NetXtreme-E BCM5750x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm233.1.135.7_Thor.pup.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-180514e4159b","Version":"233.1.135.7"}]},"MinimumActiveVersion":"226.1.107.0","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM5750x Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Broadcom NetXtreme-E BCM5750x Gigabit Ethernet NICのファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM5750x Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"7\">233.0.152.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"7\">233.0.152.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<ul><li>This software package contains NVM Image version 233.1.135.7&nbsp;with the following firmware versions:<table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE</td><td colspan=\"1\" rowspan=\"7\">233.0.152.6<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.146.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">233.0.151.0<br />&nbsp;</td></tr><tr><td>Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE&nbsp;</td></tr></tbody></table></li></ul><p>&nbsp;</p><ul><li>Recommend to upgrade to the NVM Image version 226.1.107.0 firmware first&nbsp;for this firmware package, please refer to the following link.</li></ul><p style=\"margin-left:80px\"><a href=\"https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3\" target=\"_blank\">https://www.hpe.com/global/swpublishing/MTX-99a59d3b36404166b10a37a3b3</a></p><p>&nbsp;</p>"}],"Files":[{"Bytes":"11087705","DateModified":"2025-04-09T03:53:19","FileList":["bcm233.1.135.7_Thor.pup.HPb","bcm233.1.135.7_Thor.pup.xml","payload.json"],"MD5Sum":"ad50e0c0b05a260e9f4136f867055087","Name":"bcm233.1.135.7_Thor.pup.fwpkg","Release":"2025-04-09T03:50:06","Revision":"","SHA1Sum":"27d728800d33fa0267bbb9407b2c109457a37edb","SHA256Sum":"d98778dfccf550c620822b8aeb9cd4dd5ad22feb148e3d842ba0e918fccbb5fb","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-175014e4159a","a6b1a447-382a-5a4f-14e4-180214e4159a","a6b1a447-382a-5a4f-14e4-180514e4159a","a6b1a447-382a-5a4f-14e4-175014e4159b","a6b1a447-382a-5a4f-14e4-180214e4159b","a6b1a447-382a-5a4f-14e4-180514e4159b"],"TypeOfChange":"1","Version":"233.1.135.7"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol style=\"list-style-type:decimal\"><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3. iLO GUIからのフラッシュ</p><ul style=\"list-style-type:square\"><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li></ul>"},{"Lang":"cn","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p><ol style=\"list-style-type:decimal\"><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul style=\"list-style-type:square\"><li><p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p></li><li><p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p><p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p><ul style=\"list-style-type:square\"><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Broadcom Firmware Package for BCM5750x adapters"},{"Lang":"ja","Value":"Broadcomファームウェアパッケージfor BCM5750xアダプター"},{"Lang":"cn","Value":"Broadcom Firmware Package for BCM5750x adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-01T09:12:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to simplify network configuration.</li><li>This product enhances system stability by adjusting MSI-X vector counts to prevent resource exhaustion.</li><li>This product enhances SPDM functionality by setting the MsgTag in the MCTP transport header.</li><li>This product enhances the coredump feature in the BNXT driver for better diagnostic capabilities.</li><li>This product enhances network performance by adding the RX rate profile and improving DPDK functionality.</li></ul>","Fixes":"<ul><li>This product fixes the issue where the firmware fails to send a reset notification to the driver during error recovery.</li><li>This product fixes the issue where the RDE bejString special character escape sequences were incorrectly encoded.</li><li>This product fixes the issue where the PLDM port link speed sensor reading and event values were reported as negative.</li><li>This product fixes the issue where the XDP/LPBK L2 context entry caused resource leaks.</li><li>This product fixes the issue where XDP flows were not properly freed by ensuring they are released only when the MAC address is non-zero.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>この製品は、ネットワーク構成を簡素化するために、Ethernet/LLDPTransmit/ManagementVlanId プロパティを削除します。</li><li>この製品は、MSI-Xベクトルカウントを調整してリソース枯渇を防ぐことで、システムの安定性を高めます。</li><li>この製品は、MCTPトランスポートヘッダーにMsgTagを設定することでSPDM機能を強化します。</li><li>この製品は、BNXTドライバーのコアダンプ機能を強化し、診断機能を向上させます。</li><li>この製品は、RXレートプロファイルを追加し、DPDK機能を改善することで、ネットワークパフォーマンスを強化します。</li></ul>","Fixes":"<ul><li>この製品は、エラー回復中にファームウェアがドライバーにリセット通知を送信できない問題を修正します。</li><li>この製品は、RDE bejString特殊文字エスケープ シーケンスが誤ってエンコードされる問題を修正します。</li><li>この製品は、PLDMポート リンク速度センサーの読み取り値とイベント値が負として報告される問題を修正します。</li><li>この製品は、XDP/LPBK L2コンテキストエントリによってリソース リークが発生する問題を修正します。</li><li>この製品は、MACアドレスがゼロ以外の場合にのみXDPフローが解放されるようにすることで、XDPフローが適切に解放されない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product removes the Ethernet/LLDPTransmit/ManagementVlanId property to simplify network configuration.</li><li>This product enhances system stability by adjusting MSI-X vector counts to prevent resource exhaustion.</li><li>This product enhances SPDM functionality by setting the MsgTag in the MCTP transport header.</li><li>This product enhances the coredump feature in the BNXT driver for better diagnostic capabilities.</li><li>This product enhances network performance by adding the RX rate profile and improving DPDK functionality.</li></ul>","Fixes":"<ul><li>This product fixes the issue where the firmware fails to send a reset notification to the driver during error recovery.</li><li>This product fixes the issue where the RDE bejString special character escape sequences were incorrectly encoded.</li><li>This product fixes the issue where the PLDM port link speed sensor reading and event values were reported as negative.</li><li>This product fixes the issue where the XDP/LPBK L2 context entry caused resource leaks.</li><li>This product fixes the issue where XDP flows were not properly freed by ensuring they are released only when the MAC address is non-zero.</li></ul>","Lang":"cn"}],"Version":"232.1.132.8"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.1.135.7"}],"SWKeys":[{"Name":"BCM_NXE_5750X_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"3a969920a470448d8f7afc77abc8e19f"}]},{"ProductId":"205e86b4ae1e4a28ae1e3cf39faf17ba","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPG5<br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Update maximum continuous operation temperature values for host thermal management and reporting.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5774042","DateModified":"2025-05-14T08:02:38","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/CP066506.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066506.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066506.scexe"],"MD5Sum":"00cc0a08bc68fe125c40429228f413be","Name":"firmware-hdd-12304c1aca-HPG6-5.1.x86_64.rpm","Release":"2025-05-14T12:49:06","Revision":"E","SHA1Sum":"4204c03381d558d97f8d6891dafd8fcdc6e93e08","SHA256Sum":"21e5e1fde00257d0bab846166d4006ffccbe95584b3a31d2275b2a1e96f39021","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"Installation":{"Command":"CP043255.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWWQH","TargetGUID":"4d2340a5-3042-3430-3030-304757575148","Type":"sata"},{"Id":"MB002000GWWQF","TargetGUID":"4d2340a5-3042-3230-3030-304757575146","Type":"sata"},{"Id":"MB001000GWWQE","TargetGUID":"4d2340a5-3042-3130-3030-304757575145","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:06:30","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b50d6617906e4a4280febde98b9dea4a"}]},{"ProductId":"0d3c26d8a354471c9de6f3f842c4e5d3","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."},{"Lang":"ja","Value":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"569296","DateModified":"2025-03-26T06:44:21","FileList":["cp066512.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"MD5Sum":"265ee7cdb78ef3e614a282215af8b3fb","Name":"cp066512.exe","Release":"2025-03-26T06:41:58","Revision":"","SHA1Sum":"77f2662d765dda2a74c14b4a5045918ff49c959a","SHA256Sum":"a85648b639834566107df7e76d3fd26d0079a1753e3bc90b979ca126c5cd2f5b","Size":"555KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.1.0.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />Click the &quot;Install&quot; button to perform the driver installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"100"},"SupportedDevices":[{"Dev":"4000","SubDev":"4000","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-400011f84000","Type":"pci","Ven":"11F8"},{"Dev":"4052","SubDev":"4052","SubVen":"11F8","TargetGUID":"a6b1a447-382a-5a4f-11f8-405211f84052","Type":"pci","Ven":"11F8"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-04-26T02:40:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial release</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.0.0"}],"SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1e6f365e9fd24516a483d8c998d61f49"}]},{"ProductId":"1368ab3d45fb40b799c33ccbe297c322","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11927906","DateModified":"2025-05-14T03:45:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/CP067195.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/U30_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067195.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067195.scexe"],"MD5Sum":"c7a2da2601392f0337e6d0223545459f","Name":"firmware-system-u30-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-14T08:36:21","Revision":"B","SHA1Sum":"353401f3d840d41b0e928b0143ae86df3fdacd73","SHA256Sum":"7244fb3fb7bc0f157d260c33e74fad55156b87de09c41992ce21e4acd442b072","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"cn","Value":"用于 Linux 的 ROM Flash 组件 - HPE ProLiant DL380 Gen10 (U30) 服务器"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen10(U30)サーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T08:34:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"80741f6311c84598ae917b5b79cd7a58"}]},{"ProductId":"1607ed48320345de80b2a91bfe782685","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1036088","DateModified":"2025-04-01T06:43:21","FileList":["cp065277.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"MD5Sum":"81f157951f654091e5c70eb3382ec57b","Name":"cp065277.exe","Release":"2025-04-01T06:28:38","Revision":"C","SHA1Sum":"b02dd8639a74b2b5e3afd444025cb35b2827b279","SHA256Sum":"39b167537ac6151bd30338dd002eba3ea0271fde3d2d6dc08d0b3668341c668f","Size":"0MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel ixs Driver for Windows Server 2022"},{"Lang":"ja","Value":"Windows Server 2022用HPE Intel ixsドライバー"},{"Lang":"cn","Value":"HPE Intel ixs Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:41:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、Azure Stack HCI OSをサポートするようになりました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"4.1.254.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"4.1.254.0"}],"SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"beed53fc6cfa409f93be5a9d64c1b49b"}]},{"ProductId":"bd2780f798b64cefbb3916c847ffd755","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.01"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.01"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020501.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.01"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021101.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.01"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Fibre Channel"},{"Lang":"ja","Value":"ファームウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"固件 - 存储光纤通道"}],"Description":[{"Lang":"en","Value":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"Lang":"ja","Value":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターをアップグレートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7944884","DateModified":"2025-07-04T09:04:30","FileList":["/CP067635_BUILD_1.data","/CP067635.vmexe","/CP067635.vmexe64","/CP067635.vmfile","/CP067635_VMw.zip","/CP067635.xml","/payload.json","/CP067635_VMw.zip/index.xml","/CP067635_VMw.zip/vendor-index.xml","/CP067635_VMw.zip/metadata.zip","/CP067635_VMw.zip/vib20/CP067635/HPE_bootbank_CP067635_2025.05.02.1-8.0.0.20613240.vib","/CP067635_VMw.zip/metadata.zip/vendor-index.xml","/CP067635_VMw.zip/metadata.zip/vmware.xml","/CP067635_VMw.zip/metadata.zip/vibs/CP067635--8389085864836919735.xml","/CP067635_VMw.zip/metadata.zip/bulletins/Smart-Component-CP067635_2025.05.02.1-8.0.0.20613240.xml"],"MD5Sum":"68e58841a1b5ff45989b46d20f0c9a7d","Name":"CP067635.zip","Release":"2025-07-04T08:59:44","Revision":"","SHA1Sum":"f858dcf78d9e436378af2df7bb4ff9459c2e388f","SHA256Sum":"badd82f7a4bf33b321d2f119331971cc6621416bbf83088925a2b7b74815b54e","Size":"7MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2025.05.02","VibList":[{"Name":"CP067635","Version":"2025.05.02.1-8.0.0.20613240"}]}],"Installation":{"Command":"hpsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />Offline:</strong></p><ul><li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li></ul><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the component to the Service Pack for ProLiant</li><li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li><li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter :</strong></p><ul><li>Log in to the vSphere Client.</li><li>Select a server or cluster in the inventory tree.</li><li>Click the HPE Insight Management tab.</li><li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li></ul><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li><li>From the same directory, unzip the Smart Component.<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li><li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>To perform the standalone installation, execute the command:</li><li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li><li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:<ul><li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li></ul></li><li>To perform standalone installation of the firmware,Execute the command:<ul><li>./ Execute_Component</li></ul></li><li>Follow the directions given by the Smart Component</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host</li><li>Reboot your system, if required, for the firmware update to take effect</li></ul>"},{"Lang":"ja","Value":"<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />オフライン：</strong></p><ul><li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li></ul><p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにコンポーネントを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li><li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p> </p><p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p><ul><li>vSphereクライアントにログインします。</li><li>インベントリツリーのサーバーまたはクラスターを選択します。</li><li>HPE Insight Managementタブをクリックします。</li><li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li></ul><p> </p><p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>ESXiホスト上のTech Support Modeを有効にします。</li><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li><li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li><li>同じディレクトリからSmartコンポーネントをunzipします。<ul><li>unzip CPxxxxxx.zip</li></ul></li><li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li><li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：<ul><li>chmod +x CPxxxxxx_VMw.zip</li></ul></li><li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li><li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li><li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：<ul><li>cd /opt/Smart_Component/<CPxxxxxx></li></ul></li><li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：<ul><li>./ Execute_Component</li></ul></li><li>Smartコンポーネントの指示に従います。</li><li>ログアウトします。</li><li>ESXiホスト上のTech Support Modeを無効にします。</li><li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPEファームウェアフラッシュfor QLogicファイバーチャネルホストバスアダプター for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-24T08:56:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">このファームウェアパッケージには、以下のファームウェアバージョンが含まれています。</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">アダプター</p></td><td><p dir=\"LTR\">速度</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">ファームウェア</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">ブートBIOS</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBデュアルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GBシングルポートPCIeファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbデュアルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gbシングルポートファイバーチャネルホストバスアダプター</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gbデュアルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gbシングルポートファイバーチャネルホストバスアダプター</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.04.09</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.10.09</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.10.09</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.01"},{"ReleaseNotes":[{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"en"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"ja"},{"Enhancements":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p><table border=\"1\"><tbody><tr><td><p dir=\"LTR\">Adapter</p></td><td><p dir=\"LTR\">Speed</p></td><td><p dir=\"LTR\">MBI</p></td><td><p dir=\"LTR\">Firmware</p></td><td><p dir=\"LTR\">UEFI</p></td><td><p dir=\"LTR\">Boot Bios</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">16Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.05.01</p></td><td><p dir=\"LTR\">9.15.05</p></td><td><p dir=\"LTR\">7.28</p></td><td><p dir=\"LTR\">3.68</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td><p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p></td><td><p dir=\"LTR\">32Gb</p></td><td><p dir=\"LTR\">02.11.01</p></td><td><p dir=\"LTR\">09.15.05</p></td><td><p dir=\"LTR\">7.39</p></td><td><p dir=\"LTR\">0.0</p></td></tr><tr><td>HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr><tr><td>HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter</td><td>64Gb</td><td>02.11.01</td><td>09.15.05</td><td>7.39</td><td>0.0</td></tr></tbody></table>","Fixes":"","Lang":"cn"}],"Version":"2025.05.02"}],"SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ecce612137054aeb911de79c65c4dce6"}]},{"ProductId":"a5e366733eda432d8665f3d8aaa40d56","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;4ICRHPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"18575392","DateModified":"2025-03-07T06:57:29","FileList":["/CP065925_BUILD_5.data","/CP065925.vmexe64","/CP065925.vmfile","/CP065925_VMw.zip","/CP065925.xml","/payload.json","/CP065925_VMw.zip/index.xml","/CP065925_VMw.zip/vendor-index.xml","/CP065925_VMw.zip/metadata.zip","/CP065925_VMw.zip/vib20/CP065925/HPE_bootbank_CP065925_4ICRHPK3.5-8.0.0.20613240.vib","/CP065925_VMw.zip/metadata.zip/vendor-index.xml","/CP065925_VMw.zip/metadata.zip/vmware.xml","/CP065925_VMw.zip/metadata.zip/vibs/CP065925--1260422250758343006.xml","/CP065925_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065925_4ICRHPK3.5-8.0.0.20613240.xml"],"MD5Sum":"5e87e2b9b27ae101a8e79134d5c4f4b4","Name":"CP065925.zip","Release":"2025-03-07T06:56:36","Revision":"H","SHA1Sum":"7143d6150c74e16e85576fde4528adf97ab72749","SHA256Sum":"256d8a603788eaa0e63e454d058830ea56b19357197882e428b8a345061c49ef","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3","VibList":[{"Name":"CP065925","Version":"4ICRHPK3.5-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO006400KWVVA","TargetGUID":"4d2340a5-304f-3630-3430-304b57565641","Type":"nvme"},{"Id":"VO004000KWVUR","TargetGUID":"562340a5-304f-3430-3030-304b57565552","Type":"nvme"},{"Id":"MO003200KWVUV","TargetGUID":"4d2340a5-304f-3330-3230-304b57565556","Type":"nvme"},{"Id":"VO002000KWVVC","TargetGUID":"562340a5-304f-3230-3030-304b57565643","Type":"nvme"},{"Id":"MO001600KWVUU","TargetGUID":"4d2340a5-304f-3130-3630-304b57565555","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T06:12:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li _msthash=\"61\" _msttexthash=\"1384240\">Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"4ICRHPK3"}],"SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0d29c281641d41adbcbc3c3426d12e2a"}]},{"ProductId":"c165fa12d9644f82b813c7e585ce9181","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064979.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2450199","DateModified":"2025-05-15T04:12:35","FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/CP067258.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/cp064979.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/cp064979.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.700-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067258.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067258.scexe"],"MD5Sum":"e8c657ce8fbd825f7db6bd8b79bc0149","Name":"firmware-dl20gen10plus_me-06.00.03.700-2.1.x86_64.rpm","Release":"2025-05-15T09:03:30","Revision":"B","SHA1Sum":"3a797168473021a59d4a5db425e04971b77ebb9d","SHA256Sum":"a0052c4b8c1212b756a16aa786305d138fc8836af8d638fe806d13798f940e77","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T09:02:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d9e9b9d9233d45dd9d1c27327a85f47d"}]},{"ProductId":"17203fd912204cbc96571639dbe02ea0","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、MB016000GWZHD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4155216","DateModified":"2025-01-11T11:00:18","FileList":["cp065083.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSTG1.rel"],"MD5Sum":"9d6a5da163541e3872a3d62ce45b9701","Name":"cp065083.exe","Release":"2025-01-11T10:55:58","Revision":"E","SHA1Sum":"88d137a543c44a1cf6190ab335a8af73a0294f79","SHA256Sum":"6927b6d4e09c580b0b920c9b6c774332959fa105f5bc689eaf0c9c7b9425f624","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000GWZGT、MB012000GWZGU、MB014000GWZGV、およびMB016000GWZHDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000GWZGT","TargetGUID":"4d2340a5-3042-3031-3030-3047575a4754","Type":"sata"},{"Id":"MB012000GWZGU","TargetGUID":"4d2340a5-3042-3231-3030-3047575a4755","Type":"sata"},{"Id":"MB014000GWZGV","TargetGUID":"4d2340a5-3042-3431-3030-3047575a4756","Type":"sata"},{"Id":"MB016000GWZHD","TargetGUID":"4d2340a5-3042-3631-3030-3047575a4844","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:26:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"30265f975a514468aa7df3085907daef"}]},{"ProductId":"f1e144df7ff3445292cda5ea1ed9d30c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB002000JWFVNおよびMB004000JWFVP"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5158232","DateModified":"2025-05-15T10:28:36","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/CP066595.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/TATCATRsnSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066595.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066595.scexe"],"MD5Sum":"97d02cbf7c99322fce17d9c711898ae2","Name":"firmware-hdd-d7af557f47-HPD4-10.1.x86_64.rpm","Release":"2025-05-15T15:17:04","Revision":"J","SHA1Sum":"ca8de8f471e63f8997e8d18b49e12f028ef9502d","SHA256Sum":"97072c94e607eaada00871f79ade4cfc22f753ce13125e256878e307e7f2a31c","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041753.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB002000JWFVN and MB004000JWFVP Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000JWFVNおよびMB004000JWFVP ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB002000JWFVN","TargetGUID":"4d2340a5-3042-3230-3030-304a5746564e","Type":"sas"},{"Id":"MB004000JWFVP","TargetGUID":"4d2340a5-3042-3430-3030-304a57465650","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T18:01:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB002000JWFVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JWFVP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cb83a1ddc2cc43fe98b70c610fbf6488"}]},{"ProductId":"ae4ca58542c143b088e01d17c537b7ac","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD3"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD3"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD3"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD3"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKLおよび、MB018000JYDKN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0&nbsp; &nbsp; &nbsp;</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20292835","DateModified":"2025-03-06T13:18:08","FileList":["/CP065975_BUILD_2.data","/CP065975.vmexe64","/CP065975.vmfile","/CP065975_VMw.zip","/CP065975.xml","/payload.json","/CP065975_VMw.zip/index.xml","/CP065975_VMw.zip/vendor-index.xml","/CP065975_VMw.zip/metadata.zip","/CP065975_VMw.zip/vib20/CP065975/HPE_bootbank_CP065975_HPD3.2-1OEM.800.1.0.20613240.vib","/CP065975_VMw.zip/metadata.zip/vendor-index.xml","/CP065975_VMw.zip/metadata.zip/vmware.xml","/CP065975_VMw.zip/metadata.zip/vibs/CP065975--5976768607522894843.xml","/CP065975_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065975_HPD3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4ef9c66b80e436651e6a258ef2eaa157","Name":"CP065975.zip","Release":"2025-03-06T13:17:22","Revision":"C","SHA1Sum":"3f9b97ba2a5e7640fc34f5213c4efbd7614ba476","SHA256Sum":"3ae7e9cce66ab6b6d26966d7f224a27f0b893d40388764b5cee5c3671666343a","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP065975","Version":"HPD3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP058615.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JYDKK、MB012000JYCJF、MB014000JYCJV、MB016000JYDKL、およびMB018000JYDKNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB010000JYDKK","TargetGUID":"4d2340a5-3042-3031-3030-304a59444b4b","Type":"sas"},{"Id":"MB012000JYCJF","TargetGUID":"4d2340a5-3042-3231-3030-304a59434a46","Type":"sas"},{"Id":"MB014000JYCJV","TargetGUID":"4d2340a5-3042-3431-3030-304a59434a56","Type":"sas"},{"Id":"MB016000JYDKL","TargetGUID":"4d2340a5-3042-3631-3030-304a59444b4c","Type":"sas"},{"Id":"MB018000JYDKN","TargetGUID":"4d2340a5-3042-3831-3030-304a59444b4e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:54:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"add09b8f197e457aa7e56438d589784e"}]},{"ProductId":"7204c0f5c514445a87ae5a6c742f6a37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp;&nbsp; &nbsp;- The RPM package name was changed from (<strong>hp</strong>-i40e-kmp-default) to (i40e-kmp-default). Now we revert this change from (i40e-kmp-default) to (<strong>hp</strong>-i40e-kmp-default).<br />&nbsp;&nbsp; &nbsp;- The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-i40e-kmp-default and i40e-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e i40e-kmp-default and then install the updated RPM.</li></ul>"},{"Lang":"ja","Value":"<ul><li>このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。<br />* 以前のWebリリースi40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-i40e-kmp-default）から（i40e-kmp-default）に変更されました。この変更を（i40e-kmp-default）から（<strong>hp</strong>-i40e-kmp-default）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* <strong>hp</strong>-i40e-kmp-defaultとi40e-kmp-defaultはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにi40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e i40e-kmp-defaultによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</li></ul>"},{"Lang":"cn","Value":"<ul><li>This component fallback the RPM format to old version for consistency in the same OS major version.<br />* The previous web release i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm is unpublished<br />&nbsp;&nbsp; &nbsp;- The RPM package name was changed from (<strong>hp</strong>-i40e-kmp-default) to (i40e-kmp-default). Now we revert this change from (i40e-kmp-default) to (<strong>hp</strong>-i40e-kmp-default).<br />&nbsp;&nbsp; &nbsp;- The new RPM release is deferred to next new OS major release<br />* <strong>hp</strong>-i40e-kmp-default and i40e-kmp-default are different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install i40e-kmp-default-2.23.17_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm, please uninstall the previous RPM by #rpm -e i40e-kmp-default and then install the updated RPM.</li></ul>"}],"Files":[{"Bytes":"447110","DateModified":"2025-04-01T09:06:18","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"MD5Sum":"dec9051ece94b69d82f2818baa417ded","Name":"hp-i40e-kmp-default-2.27.8_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T08:55:07","Revision":"","SHA1Sum":"456dceae4dbfcfb990b3f4dc4d4cb8f0a36b36dc","SHA256Sum":"55de883de2fbb826c347986be10d51073b3b5caa1b84574c7c8200cca228711b","Size":"436KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.27.8-1"},{"Bytes":"358755","DateModified":"2025-04-01T09:02:03","FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/hp-i40e","./lib/modules/5.14.21-150500.53-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"MD5Sum":"bec40e37ee4f37400193a87dac9515e1","Name":"hp-i40e-kmp-default-2.27.8_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T08:55:07","Revision":"","SHA1Sum":"baa0f2d635e279d27761dae43eaccd17893f0ea5","SHA256Sum":"3976084dffbcb52295f7177f4d94f52124737072885be7ffe5b765e03795c79f","Size":"350KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.27.8-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:12:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"<p>This product fixes warning message: index 1 is out of range.</p>","Lang":"en"},{"Enhancements":"<p>この製品は、現在SUSE Linux Enterprise Server 15 SP6をサポートしています。</p>","Fixes":"<p>この製品は、警告メッセージ「インデックス1は範囲外です」を修正します。</p>","Lang":"ja"},{"Enhancements":"<p>This product now supports SUSE Linux Enterprise Server 15 SP6.</p>","Fixes":"<p>This product fixes warning message: index 1 is out of range.</p>","Lang":"cn"}],"Version":"2.26.8-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"2.27.8-1"}],"SWKeys":[{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"cdf5541730b840b9ab59c0dda22f9d4c"}]},{"ProductId":"d217387da75b452f91f63bc9a4605e37","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"Lang":"ja","Value":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン14.4.393.20 のEmulex Storportドライバーfor Extended Systemが含まれています。"},{"Lang":"cn","Value":"The HPE Storage Fibre Channel (FC) adapter kit contains version 14.4.393.20 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"4307808","DateModified":"2025-03-13T13:03:17","FileList":["cp063482.xml","cpqsetup.exe","elxdrvr-fc-14.4.393.20-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"MD5Sum":"e8d8f2f80ac3d3c783fe789ea4a94bab","Name":"cp063482.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"658f69c14442d95f2f811ab82b43d775451b9231","SHA256Sum":"9e4c826a781a85d51a240d3354a415db9fc0587566f06540aade34ae185b3cb5","Size":"4MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.393.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p><p>［インストール］ボタンをクリックして、インストールを開始します。</p><p> </p>"},{"Lang":"cn","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:56:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br /> </p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>ドライバーバージョン14.4.393.20にアップデートしました</p><p>rawドライバーファイルは、Smartコンポーネントを解凍し、その後Emulexインストーラーを解凍することによって取得することができます。  次のコマンドを使用します。</p><p>     elxdrvr-fc-version.exe /q2 extract=2</p><p>解凍されたファイルは次に置かれます。</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>各キットのフォルダーは、それに続くアーキテクチャーとOSフォルダーを持ちます。  例、</p><p>     C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br /> </p><p> </p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to driver version&nbsp;14.4.393.20</p><p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p><p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p><p>The extracted files are located:</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p><p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p><p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019<br /><br /><br /><br />&nbsp;</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.393.20"}],"SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bffcafc491a54117afdc65f7e42d19f4"}]},{"ProductId":"2ea9059fa42b417a890b2c9927375976","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"601912","DateModified":"2025-07-01T09:07:13","FileList":["cp067693.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"b4aac167d9ebb7134d041ffaf7ed8939","Name":"cp067693.exe","Release":"2025-07-01T09:05:00","Revision":"B","SHA1Sum":"21f309ef52f497be46ecd217926977ce5b2ba861","SHA256Sum":"164f57fc86d1ed5b40545910cce6dafccad58c5e8fb5c3e02d14ed11174aee00","Size":"587KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.2.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーfor Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Azure Local 24H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-08-01T08:19:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.2.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\nechesasr.inf_amd64_4549a532e2f9c151"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a48d92cf9e3e4012953c44487bbac75e"}]},{"ProductId":"fae7c963a551489594d913b81c29f2a4","Versions":[{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Power Management"},{"Lang":"ja","Value":"ファームウェア - パワー マネジメント"},{"Lang":"cn","Value":"固件 - 电源管理"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"150919","DateModified":"2024-08-21T05:17:20","FileList":["payload.json","PICGen10-1.1.4-1.xml","PICGen10_v1.1.4_hdr.signed.hex"],"MD5Sum":"72db6077bfaa2f75f2a81ea7b943e554","Name":"PICGen10-1.1.4-1.fwpkg","Release":"2024-08-21T05:13:02","Revision":"B","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","Size":"147KB","TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u>USB Key Creator Utility</u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong>（SPP）ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><u>USB Key Creator Utility</u></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the <strong><u>USB Key Creator Utility</u></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-09-21T03:24:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p><p>なし</p><p><strong>ファームウェアの依存関係：</strong></p><p>HPE ProLiant Gen10 Plusサーバーの場合、このバージョンにアップグレードするには、iLO5バージョン2.55以降が必要です。</p><p><strong>機能強化/新しい機能：</strong></p><p>大量の電力を消費するデバイスが導入された場合にマシンの電源障害を回避するために、特定の動作が変更されました。</p><p><strong>修正された問題点：</strong></p><p>なし</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p><p>None</p><p><strong>Firmware Dependencies:</strong></p><p>For HPE ProLiant Gen10 Plus servers, iLO5 version 2.55 or above is required to upgrade to this version.</p><p><strong>Enhancements/New Features:</strong></p><p>Changed certain behaviors to avoid machine power failures when significant power consumption devices are introduced.</p><p><strong>Problems Fixed:</strong></p><p>None</p><p><strong>Known Issues:</strong></p><p>None</p>","Fixes":"","Lang":"cn"}],"Version":"1.1.4"}],"SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"84e80a3fb2e04c93b20e3b09f3a5d3c5"}]},{"ProductId":"4a7391c65f0b46d485ea7105b1cfb339","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33996113","DateModified":"2025-05-21T08:23:41","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/A47_3.72_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/CP067158.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-3.72_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067158.scexe"],"MD5Sum":"170ac6b2a1442ed0866f3cd802a08c32","Name":"firmware-system-a47-3.72_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"051d69403b2c35f2bab0ff968eb60283cfe4637f","SHA256Sum":"f4442e99b1776eb9869055d3d0b3324b0d3fe4d99d44e0e35579ba54799ccd10","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f8bdb2afe8944600ab6d203f3868197f"}]},{"ProductId":"a6447acbde7f4368991a3df1503f91e8","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB008000GWRTC"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWRTC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20383030","DateModified":"2025-03-07T06:42:59","FileList":["/CP065990_BUILD_4.data","/CP065990.vmexe64","/CP065990.vmfile","/CP065990_VMw.zip","/CP065990.xml","/payload.json","/CP065990_VMw.zip/index.xml","/CP065990_VMw.zip/vendor-index.xml","/CP065990_VMw.zip/metadata.zip","/CP065990_VMw.zip/vib20/CP065990/HPE_bootbank_CP065990_HPG1.4-1OEM.800.1.0.20613240.vib","/CP065990_VMw.zip/metadata.zip/vendor-index.xml","/CP065990_VMw.zip/metadata.zip/vmware.xml","/CP065990_VMw.zip/metadata.zip/vibs/CP065990--8605900652559021075.xml","/CP065990_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065990_HPG1.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"959d6dc9d6fdbef08b68c47c0bc2836d","Name":"CP065990.zip","Release":"2025-03-07T06:42:05","Revision":"K","SHA1Sum":"7df7484743fbfe9fda1169a0c5a84f68aa19093b","SHA256Sum":"899dcae4446c070c623988d1103c495ad3944b656e6566425503e76ef55b4663","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065990","Version":"HPG1.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041481.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000GWRTCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB008000GWRTC","TargetGUID":"4d2340a5-3042-3830-3030-304757525443","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:08:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"b4d49336f3f94c119afb40b5f43eca2c"}]},{"ProductId":"7f5cc2735e814d67a516e6e72cb03eec","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"},{"Lang":"ja","Value":"このコンポーネントは、HPE SmartアレイGen10、Gen10Plus EシリーズおよびPシリーズのコントローラーとGen11 SRコントローラーのサポートを提供します"},{"Lang":"cn","Value":"This component provides support for the HPE Smart Array Gen10, Gen10Plus E-series and P-series controllers and Gen11 SR controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"771848","DateModified":"2025-01-09T07:08:20","FileList":["cp062903.xml","cpqsetup.exe","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"MD5Sum":"a63f761614eb0e41cac373c308367029","Name":"cp062903.exe","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"17dbeb036f43b008ce40e880e0f73d7845bd5144","SHA256Sum":"726f888ac754808284280eb5085efce474ec321b12b0c033313a79e94a9471c5","Size":"753KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.10.0.1004"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019, Windows Server 2022 and Windows Server 2025"},{"Lang":"ja","Value":"HPE SmartアレイGen10、Gen10Plus、およびGen11コントローラードライバーfor Windows Server 2016、Windows Server 2019、Windows Server 2012およびWindows Server 2025"},{"Lang":"cn","Value":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019, Windows Server 2022 and Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:21:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>  Windows Server 2025のサポートを追加しました。</li><li>Windows Server 2025のDMA再マッピング機能を有効にするサポートが追加されました。</li></ul>","Fixes":"<ul><li>リモートキー管理モードが有効になっている場合にメモリダンプをキャプチャーできない場合がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"cn"}],"Version":"1016.10.0.1004"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>  Windows Server 2025のサポートを追加しました。</li><li>Windows Server 2025のDMA再マッピング機能を有効にするサポートが追加されました。</li></ul>","Fixes":"<ul><li>リモートキー管理モードが有効になっている場合にメモリダンプをキャプチャーできない場合がある問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Windows Server 2025.</li><li>Added support to enable DMA remapping feature for Windows Server 2025.</li></ul>","Fixes":"<ul><li>Fixed the issue that memory dump sometimes cannot be captured when Remote Key Management mode is enabled.</li></ul>","Lang":"cn"}],"Version":"1016.10.0.1004"}],"SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"01e6000ed7444b49b810f2c4cd99e9ae"}]},{"ProductId":"2232e2b621a84f55a544f2a4ed765213","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VMK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br /><br /><strong>Last Recommended or Critical Version:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VMK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ</p><p><strong>リリースバージョンおよび/または日付:<br />      </strong>HPG1<br /><br /><strong>最新の推奨またはクリティカルバージョン：<br />      </strong>なし<br /><br /><strong>前のファームウェアバージョン：</strong><br />      なし</p><p><strong>ファームウェアの関連性：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"21434641","DateModified":"2025-03-06T11:42:14","FileList":["/CP065947_BUILD_4.data","/CP065947.vmexe64","/CP065947.vmfile","/CP065947_VMw.zip","/CP065947.xml","/payload.json","/CP065947_VMw.zip/index.xml","/CP065947_VMw.zip/vendor-index.xml","/CP065947_VMw.zip/metadata.zip","/CP065947_VMw.zip/vib20/CP065947/HPE_bootbank_CP065947_HPG1.4-1OEM.800.1.0.20613240.vib","/CP065947_VMw.zip/metadata.zip/vendor-index.xml","/CP065947_VMw.zip/metadata.zip/vmware.xml","/CP065947_VMw.zip/metadata.zip/vibs/CP065947--2574758972881357601.xml","/CP065947_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065947_HPG1.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c15851175c1223f6257c4d9823115a10","Name":"CP065947.zip","Release":"2025-03-06T11:41:25","Revision":"C","SHA1Sum":"25de5953c63467cba9e44310fa679ce647623e7a","SHA256Sum":"fa4955802766ed99cd89b52cf8b4ec6f48ea39adb97ace426003d6baca1ee1f1","Size":"20MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP065947","Version":"HPG1.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040671.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives."},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VMK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:33:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d9ce784d3c6446d0a0b58f1fc7bafd70"}]},{"ProductId":"066920f0b4684f1da260602d0174d2e0","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.65.23"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.23_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.65.23"}]},"MinimumActiveVersion":"8.55.12","Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1825863","DateModified":"2024-12-11T01:47:18","FileList":["payload.json","ql_hp_ah_mbi_8.65.23_pldm.HPb","ql_hp_ah_mbi_8.65.23_pldm.xml"],"MD5Sum":"7b58c1098e4fe0020a2190e12f35881d","Name":"ql_hp_ah_mbi_8.65.23_pldm.fwpkg","Release":"2024-12-11T01:44:56","Revision":"","SHA1Sum":"c9fb2fe8893f7c2dc142ce76de467c2985e94020","SHA256Sum":"9d2d27c83a71f1423f599d05de4bcabc223bbd514f24a73249419d98b67a6a1d","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-80f0159002bd"],"TypeOfChange":"1","Version":"8.65.23"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p>&nbsp;</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p>&nbsp;</p><p>&nbsp;</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p style=\"margin-left:40px\">ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p style=\"margin-left:40px\">リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p><p> </p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p> </p><p> </p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p style=\"margin-left:40px\">localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p style=\"margin-left:40px\">remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p><p>&nbsp;</p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_7761c1b3fae845228e5a11aacf</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_1f7a14b7d04142f0b04ecb9c03</a></p><p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_45bde9430773406fb2b796799e</a></p><p>&nbsp;</p><p>&nbsp;</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters"},{"Lang":"ja","Value":"Arrowheadアダプター用HPE QLogic FastLinQファームウェアパッケージ"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-12-04T04:03:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は、ドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"8.65.14"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.65.23"}],"SWKeys":[{"Name":"NIC_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"4b658756c8a14d80ba2c6e5ea4f3a675"}]},{"ProductId":"eeaaff922a754e178b46a3315fd0a64a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p53_CFGID7p2_K97342_8000F8E2.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3755.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p53_CFGID7p2_K97470_8000F8EE.bin","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3755.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3755.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するIntel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th><strong>Single&nbsp;</strong>NVM Version</th><th><strong>FW Version</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter</td><td>8000F8E2</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td><td>8000F8EE</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter</td><td>8000123F</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td><td>80001234</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (2-port)</td><td>8000119C</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (4-port)</td><td>8000119D</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>The combo image v1.3755.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th><strong>Single&nbsp;</strong>NVM Version</th><th><strong>FW Version</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter</td><td>8000F8E2</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td><td>8000F8EE</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter</td><td>8000123F</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td><td>80001234</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (2-port)</td><td>8000119C</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (4-port)</td><td>8000119D</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>The combo image v1.3755.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM/NVM Version</th><th>OROM Version</th><th><strong>Single&nbsp;</strong>NVM Version</th><th><strong>FW Version</strong></th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter</td><td>8000F8E2</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td><td>8000F8EE</td><td>1.3755.0</td><td>N/A</td><td>9.53</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter</td><td>8000123F</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td><td>80001234</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (2-port)</td><td>8000119C</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr><tr><td>Intel(R) I350 Gigabit Network Connection (4-port)</td><td>8000119D</td><td>1.3755.0</td><td>N/A</td><td>N/A</td></tr></tbody></table><p>The combo image v1.3755.0&nbsp;includes: Boot Agent: 1GbE - v1.5.90, 10GbE - v2.4.54, 40GbE - v1.1.45 &amp; UEFI Drivers: 1GbE - v9.8.79, 10GbE - v8.2.76, 40GbE - v5.0.17</p>"}],"Files":[{"Bytes":"4588634","DateModified":"2025-04-01T02:51:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/CP064887.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/CP064887.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_X710DA2_9p53_CFGID7p2_K97470_8000F8EE.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_X710DA2_OCP3_9p53_CFGID7p2_K97342_8000F8E2.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_i350T4_K68277_8000123F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_i350T4_K68277_8000123F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.33.1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064887.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064887.scexe"],"MD5Sum":"883c6ce08f79032dd197e58b321f3f7a","Name":"firmware-nic-is-intel-1.33.1-1.1.x86_64.rpm","Release":"2025-04-01T07:40:12","Revision":"","SHA1Sum":"1653c6c21fee690994cc4cd33b3500efb0576965","SHA256Sum":"5817c2cd9b2f46521b600fd4b25c35cadf8588dedca3ac33311b7d6e1d39f002","Size":"4MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"1.33.1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li><br />&nbsp;</ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"ja","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li><br />&nbsp;</ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"},{"Lang":"cn","Value":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p><ul><li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><br /><li>The CPxxxxxx.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CPxxxxxx.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li><br /><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li><em>./</em>CPxxxxxx<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li><li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li></ul></li><br /><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><br /><em><strong>Updating firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><br /><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li><br />&nbsp;</ul><p><em><strong>Additional Information:</strong></em></p><ul><li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li><li>The results of the firmware upgrade are saved in the CPxxxxxx.log file, located at the /var/cpq/ directory.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00119171en_us</li></ul><p>&nbsp;</p><p><em><strong>Driver dependency:</strong></em></p><p>This product will scan all Intel NIC devices present in your system. If there are multiple Intel E810/X710/I350/X550 network adapters present in your system, the corresponding inbox NIC drivers may not work well with the firmware library in this product for some kernels. If you encounter errors with this product, it is required to install the Intel OOB NIC drivers (igb/ixgbe/i40e/ice) for all the Intel NIC devices on your system, regardless of which Intel device you are trying to upgrade the firmware for.</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Intel Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"1572","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1572808600a1","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"0008","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157280860008","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T08:20:01","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、最新のドライバーとの互換性を強化しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.32.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.33.1"}],"SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8538d863e08a47bfb4d3e9824e0a0063"}]},{"ProductId":"07fc1a5a961a427ba3c2e3f341d3886e","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000JWFVKおよびMB006000JWFVL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5157295","DateModified":"2025-05-15T10:13:33","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/CP066594.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/TATCATdsHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066594.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066594.scexe"],"MD5Sum":"517e9673f79ac8b452719c04417a01d0","Name":"firmware-hdd-f6d00bd17e-HPD4-9.1.x86_64.rpm","Release":"2025-05-15T15:02:05","Revision":"I","SHA1Sum":"fc0afa11fcb8f833075c03841d174fd7e493f2a1","SHA256Sum":"ab2ae4092c0e432b29dd7bb07b6753f54f785afd3970d3137928947b96efc71e","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"CP041750.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MB004000JWFVK and MB006000JWFVL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000JWFVK","TargetGUID":"4d2340a5-3042-3430-3030-304a5746564b","Type":"sas"},{"Id":"MB006000JWFVL","TargetGUID":"4d2340a5-3042-3630-3030-304a5746564c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T17:54:46","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB004000JWFVK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWFVL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"ed44c8cba8ea4ffab04a2335b4f04ba8"}]},{"ProductId":"8c2329b4625b415f9c19a0c86db985e1","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - System Management"},{"Lang":"ja","Value":"ドライバ - システム マネジメント"},{"Lang":"cn","Value":"驱动程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"590336","DateModified":"2025-01-14T06:03:20","FileList":["cp065110.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"MD5Sum":"8fa13ba0977b8e542a61d56b79edd5a0","Name":"cp065110.exe","Release":"2025-01-14T06:00:53","Revision":"G","SHA1Sum":"fa8f2b7856473718b74ea05205fa3ea72b3730b6","SHA256Sum":"4b3b3ca59134c69e518097bfb5333478103aff5bbff3f848b952a96c874da17c","Size":"576KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":60,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the driver installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてドライバーインストールを実行します。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"iLO 5自動サーバー復旧ドライバーfor Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2000"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-02-14T05:48:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>サポート環境をアップデートしました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Updated supported environments</li></ul>","Fixes":"","Lang":"cn"}],"Version":"4.7.1.0"}],"SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"70f037ccb8724ef2a09588a240ba531d"}]},{"ProductId":"7dd14e7585784238bb6caec32dcf1d80","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This driver, MegaSAS35, provides Windows 2019 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10 Controller and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 controllers"},{"Lang":"ja","Value":"This driver, MegaSAS35, provides Windows 2019 64-bit support for HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10 Controller and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 controllers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"886760","DateModified":"2025-04-25T04:45:19","FileList":["cp064818.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"MD5Sum":"a6a693a0749fbc500926af439949255f","Name":"cp064818.exe","Release":"2025-04-25T04:43:28","Revision":"","SHA1Sum":"4590458c9a263e76f6819204ff827766c2a99a4b","SHA256Sum":"901b08d5fd36c859ef3eb39265d01fe967bcdcb384c15a05e9d09e38eeb0708d","Size":"865KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":400,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>"},{"Lang":"ja","Value":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers Driver for Microsoft Windows 2019 edition"},{"Lang":"ja","Value":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers Driver for Microsoft Windows 2019 edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1440"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-16T00:00:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Add support for MR408i-p Gen11 controller</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>MR408i-p Gen11コントローラーのサポートを追加</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Add support for MR408i-p Gen11 controller</li></ul>","Fixes":"","Lang":"cn"}],"Version":"7.730.2.0"},{"ReleaseNotes":[{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Removed MR208e-p Gen 12 controller support</p>","Fixes":"","Lang":"cn"}],"Version":"7.732.3.0"}],"SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d183dd9665a64420ad8ba66a86f6c228"}]},{"ProductId":"25298d41e8ae4c7a847f78be945ec24d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWFWKおよびMB002000GWFWL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG5</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp; &nbsp;&nbsp; None&nbsp;</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20087754","DateModified":"2025-03-07T06:37:41","FileList":["/CP065937_BUILD_7.data","/CP065937.vmexe64","/CP065937.vmfile","/CP065937_VMw.zip","/CP065937.xml","/payload.json","/CP065937_VMw.zip/index.xml","/CP065937_VMw.zip/vendor-index.xml","/CP065937_VMw.zip/metadata.zip","/CP065937_VMw.zip/vib20/CP065937/HPE_bootbank_CP065937_HPG6.7-1OEM.800.1.0.20613240.vib","/CP065937_VMw.zip/metadata.zip/vendor-index.xml","/CP065937_VMw.zip/metadata.zip/vmware.xml","/CP065937_VMw.zip/metadata.zip/vibs/CP065937--192906584733724783.xml","/CP065937_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065937_HPG6.7-1OEM.800.1.0.20613240.xml"],"MD5Sum":"46d44a7d68a38c3eee1dc0f3a76fd4da","Name":"CP065937.zip","Release":"2025-03-07T06:36:51","Revision":"K","SHA1Sum":"64b09e205e4ab2fb12e5a5f8d132dba06322f331","SHA256Sum":"ffca89d758904c9386355469baf723cff0b06e0952ac85077f163828b85e02bf","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP065937","Version":"HPG6.7-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040785.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi&nbsp; 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi&nbsp; 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB001000GWFWK","TargetGUID":"4d2340a5-3042-3130-3030-30475746574b","Type":"sata"},{"Id":"MB002000GWFWL","TargetGUID":"4d2340a5-3042-3230-3030-30475746574c","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:54:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG6"}],"SWKeys":[{"Name":"MB001000GWFWK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"56af69663070424fa03eafdf58f6e6c8"}]},{"ProductId":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11828624","DateModified":"2025-04-18T10:16:51","FileList":["cp066792.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_3.50_04_17_2025.signed.flash"],"MD5Sum":"8a9808414863c67b8d597b78dc2391c6","Name":"cp066792.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"aa994fbbac2df9015249a1489d3178baf56bd4fc","SHA256Sum":"da53bae83ed171774eb3d868c3944fb4c3802b6a7d4c593163974e6dbefe3747","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL380 Gen10 (U30)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8a194b62ea93443eae46eb94f16d2499"}]},{"ProductId":"4eb73551b4784537817e4ada8a1d49b5","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34042806","DateModified":"2025-06-15T21:35:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/CP067570.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/U46_2.42_06_13_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.42_2025_06_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067570.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067570.scexe"],"MD5Sum":"e4c9c8947f08bbb9183297135805dae5","Name":"firmware-system-u46-2.42_2025_06_13-1.1.x86_64.rpm","Release":"2025-06-16T02:26:52","Revision":"","SHA1Sum":"82f54b98eb2afd734c49ea87dea472d9c89d5310","SHA256Sum":"dcd4437cb36525d0db3cd5cf6e91513deab09ae7b8b0112fbb8dbb3930028ea5","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合：<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:26:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"57d616ab59734d38a810559a378032d8"}]},{"ProductId":"df57af7543b34ffbb722ca05255bf445","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM3_1.24_G.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM3 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM3ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM3 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"63221","DateModified":"2024-09-13T04:37:23","FileList":["HPE_UBM3_1.24_G.HPb","HPE_UBM3_1.24_G.xml","payload.json"],"MD5Sum":"7575dae1c6784d476f014d39a8bcfea3","Name":"HPE_UBM3_1.24_G.fwpkg","Release":"2024-09-13T04:33:04","Revision":"G","SHA1Sum":"050a05cd30e23620f120d6a3924f44b93cc84514","SHA256Sum":"55b03510c024198f628ac042d3a19bbcb847377ff5e6be951bd6b1e516eb36f7","Size":"61KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901503000000"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus and Gen11 servers usage"},{"Lang":"ja","Value":"ファームウェアパッケージ - Gen10、Gen10 Plus、およびGen11サーバーで使用するためのUBM3バックプレーンPIC PLDMファームウェア"},{"Lang":"cn","Value":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus and Gen11 servers usage"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901503000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-04-04T09:55:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support new ML110 and DL560 Gen11 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>新しいML110およびDL560 Gen11サーバーのサポート</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new ML110 and DL560 Gen11 servers</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"UBM3PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL360 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL380 Gen12 Server"},{"Family":"","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant ML350 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"bc8e3b1eb8804b47acb76ad46bb94011"}]},{"ProductId":"ad60a281882240318ac9ec3091a5f1c9","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1728664","DateModified":"2025-03-13T12:56:14","FileList":["cp063824.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"f2c247bba71373d235fda1c2628e533a","Name":"cp063824.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"d48063200eb17d5c8dbc4db4e9a3d70b53a695c1","SHA256Sum":"608f4be0d01cf98667cedce9d99a7a072e662e45b2665e9f1eba575f8396c148","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />［インストール］ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"},{"Lang":"ja","Value":"HPE Storageファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2019"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:57:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン9.4.11.20にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated&nbsp;to&nbsp;version 9.4.11.20</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"129ddc7e30ab490f8b8e88f881a621a8"}]},{"ProductId":"ab0976902eae4e0c8757219b825c91f8","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33613990","DateModified":"2025-04-18T10:30:11","FileList":["payload.json","U30_3.50_04_17_2025.signed.flash","U30_3.50_04_17_2025.xml"],"MD5Sum":"8ac7dbccb749ca46afbf5b5ab533ab80","Name":"U30_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"c9dff78f10921bc35980b39d0c68dba0ba71e9d4","SHA256Sum":"f5d215f196ca9ce5c1a7065c61517069426ebd2c2dfa19b8ad74882798c05736","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL380 Gen10(U30)サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"4f2396465de44ba1bb72115f84686416"}]},{"ProductId":"39676e9bd8d74e11b8837e3f6ebabd5c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"Lang":"cn","Value":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"Lang":"ja","Value":"Smart Storage Administrator（SSA）は、SmartアレイおよびSmartRAIDコントローラーや他のストレージデバイス、例えばホストバスアダプター（HBA）、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。Smart Array Advanced Pack 1.0および2.0の機能は、適切なファームウェア(の使用)によりSSAのベースライン機能の一部となりました。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[{"Lang":"en","Value":"<p>Please make sure the following browser options are enabled:</p><ul><li>Automatically load images and other data types.</li><br /><li>JAVA script</li><br /><li>Style sheets</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>次のブラウザーオプションが使用可能であることを確認してください。</p><ul><li>イメージと他のデータタイプを自動的にロードします。</li><br /><li>JAVA スクリプト</li><br /><li>スタイルシート</li></ul><p> </p>"},{"Lang":"cn","Value":"<p>Please make sure the following browser options are enabled:</p><ul><li>Automatically load images and other data types.</li><br /><li>JAVA script</li><br /><li>Style sheets</li></ul><p>&nbsp;</p>"}],"Files":[{"Bytes":"9747279","DateModified":"2025-04-03T05:29:03","FileList":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"MD5Sum":"a96f0c58bba42ec7aa69347e07a60425","Name":"ssa-6.45-8.0.x86_64.rpm","Release":"2025-06-02T00:00:00","Revision":"B","SHA1Sum":"bc1a57a3613aaac78637404bb7b36153b5b3ac10","SHA256Sum":"e5c6107a49cc85d1f923fb1cf034b6451b6e48903e6e8b972589dd9ca598072c","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.45.8.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"},{"Lang":"ja","Value":"<ul><li>SSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li><li>古いバージョンのSSAがシステムにインストールされている場合、\"rpm -e ssa\"を使用して最初にそれを削除してください。</li><li>\"rpm -Uvh --oldpackage --replacefiles –replacepkgs <file name>\"を使用してアプリケーションをインストールします。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>このソフトウェアは/opt/smartstorageadmin/ssaにあり、実行可能ファイル名は/usr/sbinに配置されているssaです。</li></ul>"},{"Lang":"cn","Value":"<ul><li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs&nbsp;&lt;file name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"cn","Value":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers"},{"Lang":"ja","Value":"Smart Storage Administrator (SSA) for Linux 64ビットfor Gen10/Gen10 Plus/Gen11コントローラー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f159000e4","Type":"pci","Ven":"103C"},{"Dev":"A186","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a186159000e5","Type":"pci","Ven":"8086"},{"Dev":"A1D6","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a1d6159000e6","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"00E5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159000e5","Type":"pci","Ven":"8086"},{"Dev":"A256","SubDev":"00E6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159000e6","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"193F","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-193f1590027f","Type":"pci","Ven":"103C"},{"Dev":"A256","SubDev":"02F4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a256159002f4","Type":"pci","Ven":"8086"},{"Dev":"A206","SubDev":"02F2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a206159002f2","Type":"pci","Ven":"8086"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"},{"Id":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","TargetGUID":"422340a5-3939-4644-4237-342d07f65795","Type":"sas"},{"Dev":"8D66","SubDev":"009D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d661590009d","Type":"pci","Ven":"8086"},{"Dev":"8D06","SubDev":"009C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-8d061590009c","Type":"pci","Ven":"8086"},{"Dev":"193F","SubDev":"3381","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-103c-193f103c3381","Type":"pci","Ven":"103C"},{"Dev":"A106","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a106159000c0","Type":"pci","Ven":"8086"},{"Dev":"A107","SubDev":"00C0","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-a107159000c0","Type":"pci","Ven":"8086"},{"Dev":"3239","SubDev":"21c5","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c5","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c1","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c1","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cb","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cb","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21be","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21be","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21cc","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cc","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c3","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c3","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c0","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c0","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c2","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c2","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ca","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ca","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21BD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c4","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c4","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21CD","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21cd","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c6","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c6","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c9","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c9","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c8","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c8","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21c7","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21c7","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21bf","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21bf","Type":"pci","Ven":"103c"},{"Dev":"3239","SubDev":"21ce","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-103c-3239103c21ce","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:30:12","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>RHEL10サポートを追加しました</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"6.45.8.0"}],"SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"P89","Model":"HP ProLiant DL388 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL180 Gen9 Server"},{"Family":"U20","Model":"HPE ProLiant DL160 Gen9 Server"},{"Family":"P86","Model":"HPE ProLiant DL120 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL80 Gen9 Server"},{"Family":"U15","Model":"HPE ProLiant DL60 Gen9 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"O42","Model":"HP ProLiant ML10 Gen9 Server"},{"Family":"U23","Model":"HPE ProLiant ML30 Gen9 Server"},{"Family":"P99","Model":"HPE ProLiant ML110 Gen9 Server"},{"Family":"P95","Model":"HPE ProLiant ML150 Gen9 Server"},{"Family":"P92","Model":"HPE ProLiant ML350 Gen9 Server"},{"Family":"","Model":"HPE ProLiant XL770f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL740f Gen9 Server"},{"Family":"U18","Model":"HP ProLiant XL750f Gen9 Server"},{"Family":"U18","Model":"HPE ProLiant XL730f Gen9 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"U24","Model":"HPE ProLiant XL260a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL250a Gen9 Server"},{"Family":"U13","Model":"HPE ProLiant XL230a Gen9 Server"},{"Family":"U12","Model":"HPE ProLiant XL230b Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL190r Gen9 Server"},{"Family":"U14","Model":"HPE ProLiant XL170r Gen9 Server"},{"Family":"U14","Model":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"Family":"","Model":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"Carbondale14","Model":"<p>HPE Apollo 4520 Gen9 Chassis</p>"},{"Family":"I40","Model":"HPE Synergy 680 Gen9 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"I40","Model":"HPE Synergy 620 Gen9 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"41e56d2c7b2640a5b8badcd4805266a1"}]},{"ProductId":"b9a8e50fea15459f9f236f2538fb4a07","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"cn","Value":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2022 and Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントは、HPE Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2022およびWindows Server 2025を含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"973928","DateModified":"2025-04-17T03:42:22","FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp066646.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"MD5Sum":"2523ce862e3269a8a064e1f3850a0f9e","Name":"cp066646.exe","Release":"2025-04-17T03:28:30","Revision":"B","SHA1Sum":"14544d82f5f395d230848f1bd2a7253368ada113","SHA256Sum":"c7ac6c497d1cdefe0e5c4e011146998d482ea9068d7b01fc848f29f38efbaa69","Size":"951KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.8.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"Lang":"cn","Value":"将 Smart Component 下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击“安装”按钮进行安装。"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"cn","Value":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NX1 1Gbドライバーfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"600"},"SupportedDevices":[{"Dev":"165F","SubDev":"22E8","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c22e8","Type":"pci","Ven":"14E4"},{"Dev":"1665","SubDev":"22BD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1665103c22bd","Type":"pci","Ven":"14E4"},{"Dev":"165F","SubDev":"1786","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-165f103c1786","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"169D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c169d","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"3383","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c3383","Type":"pci","Ven":"14E4"},{"Dev":"1657","SubDev":"22BE","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-14e4-1657103c22be","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T03:12:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhances to enable RSS code to support systems with more than 256 CPU cores.</li><li>This product enhances to support Wake-on-LAN with 1G connection.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>この製品は、RSSコードが256個を超えるCPUコアを持つシステムをサポートできるように強化されています。</li><li>この製品は、1G接続でのWake-on-LANをサポートするように強化されています。</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>This product enhances to enable RSS code to support systems with more than 256 CPU cores.</li><li>This product enhances to support Wake-on-LAN with 1G connection.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"221.0.7.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"221.0.8.0"}],"SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d7886760f2ec4d57ac33319cfffefdbb"}]},{"ProductId":"d626b04e2b74450287a682c2c77ab027","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2302-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2302"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4506-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.4506"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_4506-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.4506"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージには、Windows x86_64プラットフォームでHPE Apollo A10 InfiniBand EDR（100Gb）2ポートアダプター（HPE部品番号843400-B21）、HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター（HPE部品番号872723-B21）、HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター（HPE部品番号872725-B21）のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.2302</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.4506</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.4506</td><td>HPE0000000008</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td>InfiniBand Card Type</td><td>Firmware&nbsp;Version</td><td>PSID</td></tr><tr><td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td><td>12.28.2302</td><td><p>HPE2920111032</p></td></tr><tr><td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td><td>16.35.4506</td><td>HPE0000000017</td></tr><tr><td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td><td>16.35.4506</td><td>HPE0000000008</td></tr></tbody></table>"}],"Files":[{"Bytes":"27636232","DateModified":"2025-04-22T10:57:48","FileList":["cp066768.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_2302-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX5-rel-16_35_4506-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_4506-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"ba11809c1c06f5de219bb45c14653920","Name":"cp066768.exe","Release":"2025-04-22T10:55:36","Revision":"A","SHA1Sum":"39d9f90b183c67c3145b00d6f7ddd74a98f2be36","SHA256Sum":"8486e44aac9564672c3636dcee5a5e94408cb8ccebd69caa08eb247f0c9dbd80","Size":"26MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.0.16"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p><p>&nbsp;</p><p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ（Windows x64）for HPE Mellanox IB専用ConnectX4およびConnectX5デバイス - Windows x86_64プラットフォーム"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"1013","SubDev":"00EF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000ef","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0257","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900257","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0255","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900255","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-15T06:15:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to 16.35.3006:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />&nbsp;</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 1.0.0.15(A):</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが12.28.2302にアップデートされました。</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2ポートアダプター)<br /> </li></ul><p><strong>次のデバイス用のファームウェアが16.35.3006にアップデートされました。</strong></p><ul><li>872723-B21(HPE Apollo InfiniBand EDR 100Gb 2ポート841zメザニンアダプター)</li><li>872725-B21(HPE InfiniBand EDR 100Gb 1ポート841QSFP28アダプター)<br /> </li></ul><p><strong>セキュリティ強化の機能改善</strong><br />このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。NVIDIAでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨しています。<br /> </p><p><strong>バージョン1.0.0.15(A)には、以下の新機能と変更が含まれます。</strong></p><ul><li>Azure Stack HCI 23H2のサポートを追加しました</li></ul><p><strong>バージョン16.35.4030には、以下の新機能と変更が含まれます。</strong></p><ul><li>特定の宛先に向けられたトラフィックのQPタイムアウト「再試行超過」エラーを延期するためのサポートが追加されました。この新しい機能により、ライブマイグレーションによるダウンタイム中に宛先への接続が切断されることが防止されます。</li></ul>","Fixes":"<p><strong>バージョン12.28.2302では、新たな問題は修正されていません。</strong><br /> </p><p><strong>以下の問題点がバージョン16.35.4030で修正されました。</strong></p><ul><li>VF FLRは、そのPFがFLRもトリガーするとスタックします。</li><li>ファームウェアがRoCEソースUDPポート制御用の非PFドライバー設定（SET_HCA_CAP.sw_r_roce_src_udp_portで設定）を無視した場合に、RoCEパケットに予期しないソースUDPポートが表示されました。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to 16.35.3006:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />&nbsp;</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 1.0.0.15(A):</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>New features and changes included in version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.0.15"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 12.28.2302:</strong></p><ul><li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />&nbsp;</li></ul><p><strong>Firmware for the following devices has been updated to&nbsp;16.35.4506:</strong></p><ul><li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li><li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li></ul><p>&nbsp;</p><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>New features and changes included in version 16.35.4506:</strong></p><ul><li>Added address validation in MLNX OEM CMD 0x0032 (get debug info) to be 4- bytes aligned.</li></ul>","Fixes":"<p><strong>No new issues have been fixed in version&nbsp;12.28.2302.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in version 16.35.4506:</strong></p><ul><li>Incorrect MPLS packets discards flow occurred when the GLOBAL pause capability was disabled.</li></ul>","Lang":"cn"}],"Version":"1.0.0.16"}],"SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U27","Model":"HPE ProLiant XL2x260w Gen9 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"fdae3bbea9de4de882e12596df49314f"}]},{"ProductId":"e01aaedc1c6c4e4090054a22e89562d4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Management"},{"Lang":"ja","Value":"ソフトウェア - マネジメント"},{"Lang":"cn","Value":"软件 - 管理"}],"Description":[{"Lang":"en","Value":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "},{"Lang":"ja","Value":"HPE iLOドライバーを使用することで、ソフトウェアとiLO マネジメントコントローラーの通信が可能になります。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"},{"Lang":"cn","Value":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"21752","DateModified":"2025-03-03T05:42:42","FileList":["/cp064439.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/index.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/vendor-index.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/metadata.zip","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/vib20/ilo/HPE_bootbank_ilo_800.10.9.0.17-1OEM.800.1.0.20613240.vib","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/metadata.zip/vendor-index.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/metadata.zip/vmware.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/metadata.zip/vibs/ilo-3739861628126934065.xml","/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240_24608328.zip/metadata.zip/bulletins/ilo-driver_800.10.9.0.17-1OEM.800.1.0.20613240.xml"],"MD5Sum":"47affdd0a902493622a0d404bdb575e1","Name":"cp064439.zip","Release":"2025-03-03T05:42:04","Revision":"","SHA1Sum":"0aa904dd6135510e87db882f69c579a3f5c44e09","SHA256Sum":"8ea50f4af2b8d334fb58108bed13735fc54294da9469b7b0ede162c1a91b0b59","Size":"21KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"ilo","Version":"800.10.9.0.17-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li><li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li><li>Enter the ESXi host credentials (root or administrator username and password).</li><li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li></ol><p><br /><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li><li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li><li>Enter the ESXi host credentials (root or administrator username and password).</li><li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li></ol><p><br /><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"},{"Lang":"ja","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p><ol><li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li><li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li><li>Mount the USB key on a remote server running Windows or Linux.</li><li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li><li>Select the &quot;next&quot; button.</li><li>Click &quot;Add Single Target.&quot;</li><li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li><li>Enter the ESXi host credentials (root or administrator username and password).</li><li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li></ol><p><br /><strong>To&nbsp;install this bundle using VMware tools:</strong></p><ol><li>Unzip the component zip file to extract the driver offline bundle.</li><li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li></ol><p>Refer to VMware documentation for information on the esxcli commands</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0"},{"Lang":"ja","Value":"HPE iLOドライバーバンドルSmartコンポーネントfor ESXi 8.0およびESXi 9.0"},{"Lang":"cn","Value":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"22"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-11T03:25:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support VMware ESXi 9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>VMware ESXi 9.0 をサポートします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support VMware ESXi 9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"2025.03.00"}],"SWKeys":[{"Name":"ilo-driver:800.10.9.0.17-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ilo:800.10.9.0.17-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I36","Model":"HPE ProLiant BL460c Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"P85","Model":"HPE ProLiant DL560 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I37","Model":"HPE Synergy 480 Gen9 Compute Module"},{"Family":"I39","Model":"HPE Synergy 660 Gen9 Compute Module"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9ec5fb420b6c4a50a324b7f40033231c"}]},{"ProductId":"799a5476ba934d049a4150e04e75c398","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3230-3030-304759444e4b","Version":"HPG2"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-304759445044","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB002000GYDNK and MB004000GYDPD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB002000GYDNKおよびMB004000GYDPD"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB002000GYDNK and MB004000GYDPD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; 1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp; 2. Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; 1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp; 2. Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; 1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp; 2. Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2620747","DateModified":"2024-11-28T15:19:18","FileList":["payload.json","Seagate_CimarronBP_SCIMARBPNTG2.HPb","Seagate_CimarronBP_SCIMARBPNTG2.xml"],"MD5Sum":"3a3b35de1708501399a82fcfaf6c5ebf","Name":"Seagate_CimarronBP_SCIMARBPNTG2.fwpkg","Release":"2024-11-28T15:16:46","Revision":"","SHA1Sum":"a9bc0df32fcdfd7208d6e6acd126e55778a9d96f","SHA256Sum":"be430be79ef1ecb58848fdf140deb537e2da9108665f76ef858c571bb27df93c","Size":"2MB","TargetGUIDs":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB002000GYDNKおよびMB004000GYDPD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB002000GYDNK","TargetGUID":"4d2340a5-3042-3230-3030-304759444e4b","Type":"sata"},{"Id":"MB004000GYDPD","TargetGUID":"4d2340a5-3042-3430-3030-304759445044","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-28T14:44:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Optimize thermal maximum continuous operation temperature values.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>サーマルの最大連続動作温度値を最適化します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Optimize thermal maximum continuous operation temperature values.</p>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2. Adding other logging and FW enhancements.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2. Adding other logging and FW enhancements.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>1.Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2. Adding other logging and FW enhancements.</p>","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB002000GYDNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB004000GYDPD","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"294d1ba482314731a5db35592e3627b4"}]},{"ProductId":"ddc8bdca3abc4ab8823e820be1ed4dfd","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Controller"},{"Lang":"ja","Value":"ドライバ - ストレージ コントローラ"},{"Lang":"cn","Value":"驱动程序 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"Lang":"ja","Value":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10およびGen11コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされるバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と機能強化を入手するため、インストールする必要があります。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 and Gen11 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.On some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"93128","DateModified":"2024-11-27T10:32:19","FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"MD5Sum":"a22d8dfd9fced9058a2021e00dbbf61a","Name":"smartpqi-kmp-default-2.1.32-035.sles15sp5.x86_64.rpm","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"fe68326322a8e4c8ec0876477431b56717d26806","SHA256Sum":"883affa20fa5b7971c58b136935620780b8fa474d5e0944d45e0d8e641560f63","Size":"90KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.32-035"},{"Bytes":"108985","DateModified":"2024-11-27T10:38:18","FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"MD5Sum":"bc71755b0ee33b1c9941f9266a52da71","Name":"smartpqi-kmp-default-2.1.32-035.sles15sp6.x86_64.rpm","Release":"2025-03-17T00:00:00","Revision":"","SHA1Sum":"49853dc385255a4f6a5dff6b6a9a6b38d346b6b9","SHA256Sum":"71706fcc7ababee4a25a7fedac186711e922c2d0d3f0e47ef53e4cebaf37d536","Size":"106KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.32-035"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm.</li></ul><p style=\"margin-left:40px\">If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES15 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm.</li></ul><p style=\"margin-left:40px\">If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES15 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>Login as the system administrator (root), download the RPM to a directory on<br />your hard drive and change to that directory.</p><p><strong>To install or upgrade&nbsp;the driver type:</strong></p><p>&nbsp;</p><ul><li># rpm -Uvh&nbsp;--oldpackage --replacefiles --replacepkgs smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm.</li></ul><p style=\"margin-left:40px\">If Installation attempted is failed with &ldquo;Failed Dependency&rdquo; Error below Arguments are used to re-try the Installation.</p><ul><li># rpm&nbsp;-Uvh --oldpackage --reinstall&nbsp;smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p>&nbsp;</p><p>Setup is now complete. Please REBOOT your computer NOW!!</p><p>&nbsp;</p><p>&nbsp;</p><p><strong>For SLES15 installations that will be using the Xen Hypervisor, run the following command after&nbsp;installing the driver rpm. This will ensure the updated driver is used for Xen.</strong></p><ul><li>/sbin/update-bootloader --refresh</li></ul><p>&nbsp;</p><p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p><ul><li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li></ul><p><strong><u>Enterprise Support</u></strong><br />For support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p><p>&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"Lang":"ja","Value":"HPE ProLiant Gen10、Gen10PlusおよびGen11 Smartアレイコントローラー (64-ビット) ドライバーfor SUSE LINUX Enterprise Server 15 (64ビット)"},{"Lang":"cn","Value":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0294","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900294","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DC","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0383","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900383","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0382","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900382","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"032E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0381","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f15900381","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"02DB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-9005-028f159002db","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T03:25:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed an issue that drives are still listed at the OS level when the controller is offline.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーがオフラインの場合でも、ドライブがOSレベルでリストされる問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed an issue that drives are still listed at the OS level when the controller is offline.</li></ul>","Lang":"cn"}],"Version":"2.1.32-035"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed an issue that drives are still listed at the OS level when the controller is offline.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーがオフラインの場合でも、ドライブがOSレベルでリストされる問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed an issue that drives are still listed at the OS level when the controller is offline.</li></ul>","Lang":"cn"}],"Version":"2.1.32-035"}],"SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"be68ec00d6144462901a91948dc61da7"}]},{"ProductId":"954c63f35d4743b2b629b5d17bfd860b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."},{"Lang":"ja","Value":"このコンポーネントには、HPE Storageアレイのためのファイバーチャネルホストバスアダプタードライバーサポートを提供する、QLogic Storportドライバーバージョン9.4.11.20が含まれています。"},{"Lang":"cn","Value":"This component contains version 9.4.11.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1724920","DateModified":"2025-03-13T12:55:18","FileList":["cp063826.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"MD5Sum":"8ff6197d99616c1f8f24cc12936779d1","Name":"cp063826.exe","Release":"2025-03-18T00:00:00","Revision":"","SHA1Sum":"d6e8abb280bc7bab8188ad650b1d4141526cfd7f","SHA256Sum":"b74dcf81b780d24dd47bdcc3caa9dc6f989b1ba8343e13dbaa04ec6dd627dcd7","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":180,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /><br />そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /><br />[インストール]ボタンをクリックして、インストールを開始します。<br />"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br /><br />From that drive and directory, execute the downloaded file.<br /><br />Click the &quot;Install&quot; button to proceed with the installation.<br />"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Storage ファイバーチャネルアダプターキットfor x64 QLogic Storportドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-21T04:57:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>これは Windows 2025 用の最初のドライバーです。このドライバーのバージョンは9.4.11.20です、</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"},{"ReleaseNotes":[{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>これは Windows 2025 用の最初のドライバーです。このドライバーのバージョンは9.4.11.20です、</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This is the first driver for Windows 2025 . The driver version is 9.4.11.20.</p>","Fixes":"","Lang":"cn"}],"Version":"9.4.11.20"}],"SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"db79dc860db94739ac7968363bd13855"}]},{"ProductId":"794cbcecc16344ce8539a9b80f70c157","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2025で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1076560","DateModified":"2025-03-28T07:24:19","FileList":["cp065272.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"5bbeee59678d250edd58342fe4bf1f91","Name":"cp065272.exe","Release":"2025-03-28T07:08:42","Revision":"B","SHA1Sum":"23c3a8754ee59af8abf4df3dfcd97676f61d0a14","SHA256Sum":"c131ed977f08d8acc98a6aec867c2cde703676a15b44a039f3319b701ead9706","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2025"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2025"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:34:21","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"14.1.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"14.1.5.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4983bc70954c46fbb5ce9a8ab5e55fe1"}]},{"ProductId":"9c9f3096a89f4cc7b4a9b97b01822036","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4938808","DateModified":"2025-01-11T07:34:17","FileList":["cp065074.xml","cpqsetup.exe","HPG1_PM897.bin","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"4ea9a448ef525b6653734c164233af0a","Name":"cp065074.exe","Release":"2025-01-11T07:29:38","Revision":"C","SHA1Sum":"2621d5089783947e699287df3b01822ec1e9927f","SHA256Sum":"6e1496bf5cc5a8c4748853abc91cbdc2cd6e077a5da8e0e627181d5e772cfc00","Size":"4MB","TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK000480GZXRA、MK000960GZXRB、MK001920GZXRC、およびMK003840GZXRVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MK000480GZXRA","TargetGUID":"4d2340a5-304b-3030-3438-30475a585241","Type":"sata"},{"Id":"MK001920GZXRC","TargetGUID":"4d2340a5-304b-3130-3932-30475a585243","Type":"sata"},{"Id":"MK000960GZXRB","TargetGUID":"4d2340a5-304b-3030-3936-30475a585242","Type":"sata"},{"Id":"MK003840GZXRV","TargetGUID":"4d2340a5-304b-3330-3834-30475a585256","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T05:39:26","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"8f8d35b9c5674dff9154000ae4de695f"}]},{"ProductId":"2b44e5307a9948769c51d6ac1f276915","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33611864","DateModified":"2025-04-18T14:23:07","FileList":["payload.json","U41_3.50_04_17_2025.signed.flash","U41_3.50_04_17_2025.xml"],"MD5Sum":"1ce51ebfec8804a60e07f7327fd32d21","Name":"U41_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"5bee6a3320c8c716f018038559e4a836058dd69e","SHA256Sum":"0647f80e8519e705812963d3e85ff1ff71736e37d5abc1b31298ce40698bf334","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"2be5b7c841f04aadb30e1b5e0a46421e"}]},{"ProductId":"cdb3eb30e49445858807ae13ca01829a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Windows 64 bit operating systems."},{"Lang":"cn","Value":"该软件包提供的套件，在 Windows 64 位操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"Lang":"ja","Value":"このパッケージは、Windows 64ビット オペレーティングシステムでEmulex ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1579832","DateModified":"2025-05-07T09:17:20","FileList":["cp066951.xml","cpqsetup.exe","cp_data.xml","ElxSmartSANInstaller.dll","ELXSMARTSANVer.exe","esmartsan_cfg_cn.xml","esmartsan_cfg_en.xml","esmartsan_cfg_ja.xml","get_ss_status.bat","SmartSAN_Readme.txt","smartsan_x64.exe","ss_disable.bat","ss_enable.bat"],"MD5Sum":"51ed31a60e9c43be91c21dd04b09ac16","Name":"cp066951.exe","Release":"2025-05-07T09:14:58","Revision":"r","SHA1Sum":"10e8bf52dea84b3d5b067554c5ba1599e18e79c8","SHA256Sum":"80c0ad874d27ee29bd70931ed1ba8318ceee6d2bff1095e25ba2c81fb8da7bc4","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"TypeOfChange":"0","Version":"1.0.0.1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00118338en_us&amp;page=index.html\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?doclocale=en_us&amp;docid=a00106063en_us\"><em>Smart Update Manager User Guide</em></a>&nbsp;</p><p>&nbsp;</p><p><strong>Component execution outside of HPE Synergy Support Pack</strong>:</p><ul><li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"},{"Lang":"ja","Value":"<p>これは構成可能コンポーネントです。  Smart SAN機能を有効/無効にするための構成ファイルが必要です。  実行される構成がない場合は、現在のSmart SANステータスが提示され、実行が完了します。  それ以上のアクションは行われません。</p><p>構成可能コンポーネントについて詳しくは、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00118338en_us&page=index.html\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?doclocale=en_us&docid=a00106063en_us\"><em>Smart Update Managerユーザーガイド</em></a>を参照してください。 </p><p> </p><p><strong>HPE Synergy Support Pack外でのコンポーネントの実行</strong>：</p><ul><li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</li><li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li><li>[インストール]ボタンをクリックして、インストールを開始します。</li></ul>"},{"Lang":"cn","Value":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00118338en_us&amp;page=index.html\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?doclocale=en_us&amp;docid=a00106063en_us\"><em>Smart Update Manager User Guide</em></a>&nbsp;</p><p>&nbsp;</p><p><strong>Component execution outside of HPE Synergy Support Pack</strong>:</p><ul><li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li><li>From that drive and directory, execute the downloaded file.</li><li>Click the &quot;Install&quot; button to proceed with the installation.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"cn","Value":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"},{"Lang":"ja","Value":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2016/2019/2022/2025 (x86_64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-23T09:08:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン1.0.0.1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.1"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン1.0.0.1にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.1</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.1"}],"SWKeys":[{"Name":"ELXSMARTSANVer.exe","SWKeyExpectedPath":"%systemdrive%\\StorageWorks\\Version"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"7a94918d937b400e8695b27c0481e3cc"}]},{"ProductId":"3f71b29f23c14fcb8f1f4cc9ac53400c","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;</p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"4417464","DateModified":"2025-01-11T13:05:18","FileList":["cp065097.xml","cpqsetup.exe","HVLPeAsseFD2.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"f64d8590b60a079eaf300e617f2aa7fd","Name":"cp065097.exe","Release":"2025-01-11T13:01:22","Revision":"G","SHA1Sum":"fcc79d3d2e80cc27a25c6c969ddd278811642b58","SHA256Sum":"2da9bf4fbff50a37eb39151a0666bd89e8fbabcd819784001dfaadf61191f02a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD2"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000JWRTD ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB008000JWRTD","TargetGUID":"4d2340a5-3042-3830-3030-304a57525444","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T12:34:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li> コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.</li></ul>","Fixes":"<ul><li>&nbsp;Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"efe35f9e51fb4c2a83e28ebae4c00768"}]},{"ProductId":"fc28c0050f9d4a8a94e83f990b230b39","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong></p><ul><li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85032G00</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p><p><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong></p><ul><li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li></ul>"}],"Files":[{"Bytes":"23260971","DateModified":"2025-03-06T10:04:06","FileList":["/CP065981_BUILD_3.data","/CP065981.vmexe64","/CP065981.vmfile","/CP065981_VMw.zip","/CP065981.xml","/payload.json","/CP065981_VMw.zip/index.xml","/CP065981_VMw.zip/vendor-index.xml","/CP065981_VMw.zip/metadata.zip","/CP065981_VMw.zip/vib20/CP065981/HPE_bootbank_CP065981_85032G00.3-1OEM.800.1.0.20613240.vib","/CP065981_VMw.zip/metadata.zip/vendor-index.xml","/CP065981_VMw.zip/metadata.zip/vmware.xml","/CP065981_VMw.zip/metadata.zip/vibs/CP065981--7802663147956247068.xml","/CP065981_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065981_85032G00.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"b0780c813f3b4c33adb49f118400461f","Name":"CP065981.zip","Release":"2025-03-06T10:03:20","Revision":"E","SHA1Sum":"9ec9e51452022698db5045ff96f0393c640ec81b","SHA256Sum":"bc611f091b11242c3a726de06bd2e11951b2a92a314365e209a02d4c07dd2c2b","Size":"22MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00","VibList":[{"Name":"CP065981","Version":"85032G00.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP042969.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VS003840KWXFQ","TargetGUID":"562340a5-3053-3330-3834-304b57584651","Type":"nvme"},{"Id":"VS001920KWXFP","TargetGUID":"562340a5-3053-3130-3932-304b57584650","Type":"nvme"},{"Id":"VS000960KWXFN","TargetGUID":"562340a5-3053-3030-3936-304b5758464e","Type":"nvme"},{"Id":"VS000480KXALB","TargetGUID":"562340a5-3053-3030-3438-304b58414c42","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:17:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"85032G00"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"85032G00"}],"SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9a01125032cc4fc29a1ae86c40a9dcb1"}]},{"ProductId":"ab6756bde612475998d62d4bbb8717ff","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、VO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5485600","DateModified":"2025-01-11T00:25:20","FileList":["cp064857.xml","cpqsetup.exe","GPM173XAHPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"f3c2e3868e5884816d27a95df08d8312","Name":"cp064857.exe","Release":"2025-01-11T00:20:41","Revision":"B","SHA1Sum":"ec81e5d6450ae5660085c6c1010090a98a01f35a","SHA256Sum":"80d413d232c8a2b181f389d986bd3a283c33dde6b5a20f7995944c0c228ca4f9","Size":"5MB","TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"2","Version":"HPK6"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"},{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-18T08:35:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li><li>For more information, CA is published at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li><li>For more information, CA is published at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version&nbsp;HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version&nbsp;to HPK6.</li><li>For more information, CA is published at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"30bb7173e96d49f3b38ba838938f3aba"}]},{"ProductId":"79ba405b8c19425aa9a14902b672b652","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3772.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":1800,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3772.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Gen9 and Gen10 server series HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under VMware vSphere 7.0, 8.0 and 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"24175471","DateModified":"2025-04-01T08:32:38","FileList":["/CP065264_BUILD_28.data","/CP065264.vmexe64","/CP065264.vmfile","/CP065264_VMw.zip","/CP065264.xml","/payload.json","/CP065264_VMw.zip/index.xml","/CP065264_VMw.zip/vendor-index.xml","/CP065264_VMw.zip/metadata.zip","/CP065264_VMw.zip/vib20/CP065264/HPE_bootbank_CP065264_3.26.1.28-8.0.0.20613240.vib","/CP065264_VMw.zip/metadata.zip/vendor-index.xml","/CP065264_VMw.zip/metadata.zip/vmware.xml","/CP065264_VMw.zip/metadata.zip/vibs/CP065264-210304162738435918.xml","/CP065264_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065264_3.26.1.28-8.0.0.20613240.xml"],"MD5Sum":"1fa1b35caeabccb7e1d678328424896b","Name":"CP065264.zip","Release":"2025-04-01T08:32:06","Revision":"B","SHA1Sum":"cc81e8309fb8b52cfe25d4672747b782f5a1442c","SHA256Sum":"e8484760f500464bea53b3c17e19ee3598ea132b4509502e622eb5b4a6504959","Size":"23MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"3.26.1","VibList":[{"Name":"CP065264","Version":"3.26.1.28-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":1800,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"},{"Lang":"ja","Value":"<p>手動によるインストール手順：</p><ol><li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li><li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li><li>CPxxxxxx.zipファイルをunzipします。</li><li>VMwareコンポーネントをインストールします。<ul><li>コマンドesxcli software component apply -d <fully_qualified_path>/CPxxxxxx_VMw.zipを実行します。（例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li></ul></li><li>コンポーネントがインストールされている場所に移動します。(例：\"cd /opt/Smart_Component/CPxxxxxx\")</li><li>ファームウェアをインストールするには、コンポーネントディレクトリの下のコンポーネントを実行します。 実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。<ul><li>次のコマンドを実行します。./Execute_Component -s</li></ul></li><li>インストール後、スマートコンポーネントをクリーンアップします。<ul><li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li><li>Smartコンポーネントをクリーンアップするには：<ul><li>次のコマンドを実行します：esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li></ol><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後にAC電源を再投入する必要があります。<br />HPE Ethernet 1Gb 2ポート368iアダプター<br />HPE Ethernet 1Gb 4ポート369iアダプター<br />HPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMSFP+アダプター<br />HPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li></ul>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>Execute command:&nbsp;esxcli software component apply -d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply -d /tmp/CPxxxxxx_VMware.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>To install firmware, execute component under component directory.&nbsp;When execution is complete, the flash engine will have performed the flash operation as directed.<ul><li>Execute command: ./Execute_Component -s</li></ul></li><li>After installation, clean up the Smart Component:<ul><li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>To clean up the Smart Component:<ul><li>Execute command: esxcli software component remove -n Smart-Component-CPxxxxxx</li></ul></li><li>Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />HPE Ethernet 1Gb 2-port 368i Adapter<br />HPE Ethernet 1Gb 4-port 369i Adapter<br />HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"cn","Value":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only."},{"Lang":"ja","Value":"HPE Intelオンラインファームウェアアップグレードユーティリティfor VMware（HPE ProLiant Gen9およびGen10サーバーシリーズ専用）。"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"37CE","SubDev":"0215","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37ce15900215","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0216","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900216","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0247","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900247","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FC","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fc","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1572","SubDev":"22FD","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1572103c22fd","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"37D3","SubDev":"0219","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d315900219","Type":"pci","Ven":"8086"},{"Dev":"37D1","SubDev":"0217","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d115900217","Type":"pci","Ven":"8086"},{"Dev":"37D2","SubDev":"0218","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37d215900218","Type":"pci","Ven":"8086"},{"Dev":"1581","SubDev":"00F8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1581159000f8","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:19:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>&nbsp;</p><p>This product now supports VMware 9.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p> </p><p>この製品は、現在VMware 9.0をサポートしています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>&nbsp;</p><p>This product now supports VMware 9.0</p>","Fixes":"","Lang":"cn"}],"Version":"3.25.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with the latest drivers.</p>","Fixes":"","Lang":"cn"}],"Version":"3.26.1"}],"SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"eabd17051aeb441882915696b7480ff1"}]},{"ProductId":"070f2ccb66ec4478ba85a2e3d9712434","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p>&nbsp;</p>"}],"Files":[{"Bytes":"19639050","DateModified":"2025-03-06T07:31:33","FileList":["/CP066000_BUILD_2.data","/CP066000.vmexe64","/CP066000.vmfile","/CP066000_VMw.zip","/CP066000.xml","/payload.json","/CP066000_VMw.zip/index.xml","/CP066000_VMw.zip/vendor-index.xml","/CP066000_VMw.zip/metadata.zip","/CP066000_VMw.zip/vib20/CP066000/HPE_bootbank_CP066000_HPDB.2-1OEM.800.1.0.20613240.vib","/CP066000_VMw.zip/metadata.zip/vendor-index.xml","/CP066000_VMw.zip/metadata.zip/vmware.xml","/CP066000_VMw.zip/metadata.zip/vibs/CP066000-1605751100554710823.xml","/CP066000_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066000_HPDB.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"7fdd95d35ecb715d4581eebd31af6ac2","Name":"CP066000.zip","Release":"2025-03-06T07:30:40","Revision":"B","SHA1Sum":"c3bc54c9a33b81af21cc746b566eff9c4bb472a8","SHA256Sum":"63b541f0f46929b9e30c7e1072283683999495004df2bf838fad7edd96ecfe29","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP066000","Version":"HPDB.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040541.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x&nbsp;operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that&nbsp; CPxxxxxx.vmexe64&nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"},{"Lang":"ja","Value":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"EH000300JWCPK","TargetGUID":"452340a5-3048-3030-3330-304a5743504b","Type":"sas"},{"Id":"EH000600JWCPL","TargetGUID":"452340a5-3048-3030-3630-304a5743504c","Type":"sas"},{"Id":"EH000900JWCPN","TargetGUID":"452340a5-3048-3030-3930-304a5743504e","Type":"sas"},{"Id":"EH000900JXLVU","TargetGUID":"452340a5-3048-3030-3930-304a584c5655","Type":"sas"},{"Id":"EH000300JXLVR","TargetGUID":"452340a5-3048-3030-3330-304a584c5652","Type":"sas"},{"Id":"EH000600JXLVT","TargetGUID":"452340a5-3048-3030-3630-304a584c5654","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:52:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes&nbsp;Maximum Temperature Reporting in system log.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"d3127bf38a094ef284bcda3b9b102157"}]},{"ProductId":"d54c971d2c3047569ed2e37939cd2848","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19554103","DateModified":"2025-03-06T13:56:49","FileList":["/CP065939_BUILD_2.data","/CP065939.vmexe64","/CP065939.vmfile","/CP065939_VMw.zip","/CP065939.xml","/payload.json","/CP065939_VMw.zip/index.xml","/CP065939_VMw.zip/vendor-index.xml","/CP065939_VMw.zip/metadata.zip","/CP065939_VMw.zip/vib20/CP065939/HPE_bootbank_CP065939_HPD3.2-1OEM.800.1.0.20613240.vib","/CP065939_VMw.zip/metadata.zip/vendor-index.xml","/CP065939_VMw.zip/metadata.zip/vmware.xml","/CP065939_VMw.zip/metadata.zip/vibs/CP065939-6829899646179790068.xml","/CP065939_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065939_HPD3.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"9df9827bb6d73aec3cb48ebb51ebf1f0","Name":"CP065939.zip","Release":"2025-03-06T13:55:58","Revision":"B","SHA1Sum":"5df7a56986fc7291050ffda5784d0b3fd48ba1d9","SHA256Sum":"0b92c451277d684155b1144dd6c7a2753dade3014b4bb857dfc4a011e55b4152","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"2","Version":"HPD3","VibList":[{"Name":"CP065939","Version":"HPD3.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040645.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA および MO003200JWDLBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO003200JWDLB","TargetGUID":"4d2340a5-304f-3330-3230-304a57444c42","Type":"sas"},{"Id":"MO001600JWDLA","TargetGUID":"4d2340a5-304f-3130-3630-304a57444c41","Type":"sas"},{"Id":"EO001600JWDKR","TargetGUID":"452340a5-304f-3130-3630-304a57444b52","Type":"sas"},{"Id":"MO000800JWDKV","TargetGUID":"4d2340a5-304f-3030-3830-304a57444b56","Type":"sas"},{"Id":"EO000800JWDKQ","TargetGUID":"452340a5-304f-3030-3830-304a57444b51","Type":"sas"},{"Id":"MO000400JWDKU","TargetGUID":"4d2340a5-304f-3030-3430-304a57444b55","Type":"sas"},{"Id":"EO000400JWDKP","TargetGUID":"452340a5-304f-3030-3430-304a57444b50","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:57:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、推定発効日2024年8月9日のHPE Customer Bulletin（<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>）を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=a00142174en_us</a>&nbsp;with the estimated effective date 2024/8/9</li></ul>","Lang":"cn"}],"Version":"HPD3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD3"}],"SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c510b3b7041e47f49b7d1a76cb4bb0d0"}]},{"ProductId":"e0d3905a13b74f06a63b96091e3a0b13","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-304759444e4c","Version":"HPG2"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-304759445045","Version":"HPG2"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3031-3030-304759444e4e","Version":"HPG2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB006000GYDNL、MB008000GYDPE、およびMB010000GYDNN"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; 1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp;&nbsp; 2) Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; 1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp;&nbsp; 2) Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPG1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; 1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />&nbsp;&nbsp;&nbsp;&nbsp; 2) Adding other logging and FW enhancements.<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2622088","DateModified":"2024-11-29T07:41:17","FileList":["payload.json","Seagate_CimarronBP_SCIMARBPETG2.HPb","Seagate_CimarronBP_SCIMARBPETG2.xml"],"MD5Sum":"602a77b246616e03d036f2f2e1c7c3c2","Name":"Seagate_CimarronBP_SCIMARBPETG2.fwpkg","Release":"2024-11-29T07:39:11","Revision":"","SHA1Sum":"4b970d38ff4028503e8180b4e6ad3890673a7832","SHA256Sum":"b406ad68114bec07f51ba539fa95c98416f9f07f9df4123cfd94d84037988daa","Size":"2MB","TargetGUIDs":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"TypeOfChange":"1","Version":"HPG2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ -MB006000GYDNL、MB008000GYDPE、およびMB010000GYDNN"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB006000GYDNL","TargetGUID":"4d2340a5-3042-3630-3030-304759444e4c","Type":"sata"},{"Id":"MB008000GYDPE","TargetGUID":"4d2340a5-3042-3830-3030-304759445045","Type":"sata"},{"Id":"MB010000GYDNN","TargetGUID":"4d2340a5-3042-3031-3030-304759444e4e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-29T06:52:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>Update maximum continuous operation temperature values for host thermal management and reporting.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>ホストのサーマル管理とレポートの最大連続動作温度値をアップデートします。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>Update maximum continuous operation temperature values for host thermal management and reporting.</p>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2) Adding other logging and FW enhancements.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2) Adding other logging and FW enhancements.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>1) Fixes the logic bug in the media cache cleaning abort handling that caused the drive to choose and execute the R/W command before the Request Sense to prevent assert.<br />2) Adding other logging and FW enhancements.</p>","Lang":"cn"}],"Version":"HPG2"}],"SWKeys":[{"Name":"MB006000GYDNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GYDPE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB010000GYDNN","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"25de70d01b804e29a5efa959dff10893"}]},{"ProductId":"03c87662bb3a4a57a852807a8f77de3f","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":" This component provides updated IE firmware that can be installed directly on supported Operating Systems. "},{"Lang":"ja","Value":" このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたIEファームウェアを提供します。 "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8567871","DateModified":"2025-05-15T01:15:23","FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/CP067248.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/cp051643.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/cp051643.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067248.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067248.scexe"],"MD5Sum":"b44678cfa9d909d881001df13bac5b01","Name":"firmware-iegen10plus-1.0.0.22-7.1.x86_64.rpm","Release":"2025-05-15T06:07:14","Revision":"G","SHA1Sum":"f12b5e3ac53f70644c1ef4153ce0f22b268c9924","SHA256Sum":"56ebd26e8e18c99ac1454627638b4ee94705b470b4649e8ecbef64936b554fe9","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"},{"Lang":"ja","Value":"<p><br />To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p><p>&nbsp;</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T06:06:29","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver 1.0.0.22(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver  1.0.0.22と同等です。ファームウェアをバージョン1.0.0.22にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意:</strong></p><p>Ver 1.0.0.22(F)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver  1.0.0.22と同等です。ファームウェアをバージョン1.0.0.22にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンFにアップグレードする必要はありません。</p><p>このLinuxコンポーネントは、Service Pack for ProLiant 2024.11.00.00 と互換性があります。</p><p><strong>ファームウェアの依存関係:</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(F) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision F if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p>This Linux component is compatible with Service Pack for ProLiant 2024.11.00.00.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"641ecd5e784e4b4da46db0c36bd221c2"}]},{"ProductId":"6f38004b166d42068a292e455179565f","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3438-304759434e54","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-304759434e50","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-304759434e46","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3330-3834-304759434e51","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3234-304759434e55","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-304759434e48","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304759434e4b","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304759434e4c","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304759434e4e","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304759434e45","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3234-304758505154","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304758505155","Version":"HPG4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[],"Files":[{"Bytes":"1493893","DateModified":"2024-10-17T06:15:15","FileList":["payload.json","Solidigm_S4X20_4IYYHPG4.HPb","Solidigm_S4X20_4IYYHPG4.xml"],"MD5Sum":"d6a443e6c3505bc7a1ba75be546c9b21","Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","Release":"2024-10-17T06:12:40","Revision":"","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","Size":"1MB","TargetGUIDs":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"TypeOfChange":"1","Version":"HPG4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"ja","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MK000480GYCNT","TargetGUID":"4d2340a5-304b-3030-3438-304759434e54","Type":"sata"},{"Id":"MK000960GYCNP","TargetGUID":"4d2340a5-304b-3030-3936-304759434e50","Type":"sata"},{"Id":"MK001920GYCNF","TargetGUID":"4d2340a5-304b-3130-3932-304759434e46","Type":"sata"},{"Id":"MK003840GYCNQ","TargetGUID":"4d2340a5-304b-3330-3834-304759434e51","Type":"sata"},{"Id":"VK000240GYCNU","TargetGUID":"562340a5-304b-3030-3234-304759434e55","Type":"sata"},{"Id":"VK000480GYCNH","TargetGUID":"562340a5-304b-3030-3438-304759434e48","Type":"sata"},{"Id":"VK000960GYCNK","TargetGUID":"562340a5-304b-3030-3936-304759434e4b","Type":"sata"},{"Id":"VK001920GYCNL","TargetGUID":"562340a5-304b-3130-3932-304759434e4c","Type":"sata"},{"Id":"VK003840GYCNN","TargetGUID":"562340a5-304b-3330-3834-304759434e4e","Type":"sata"},{"Id":"VK007680GYCNE","TargetGUID":"562340a5-304b-3730-3638-304759434e45","Type":"sata"},{"Id":"VR000240GXPQT","TargetGUID":"562340a5-3052-3030-3234-304758505154","Type":"sata"},{"Id":"VR000480GXPQU","TargetGUID":"562340a5-3052-3030-3438-304758505155","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-17T05:48:44","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>HPG3 is a planned maintenance release covering bug fixes for 2.5&rdquo; and M.2.&nbsp;There are no critical functional updates, and risk is low for customers who do not upgrade, especially if drives are not stored without power for a long period of time (~2 years).</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This is a planned maintenance release covering bug fixes. This firmware includes updates to improve PLI circuit reliability.</li></ul>","Lang":"cn"}],"Version":"HPG4"}],"SWKeys":[{"Name":"MK000480GYCNT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK000960GYCNP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK001920GYCNF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK003840GYCNQ","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000240GYCNU","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000480GYCNH","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000960GYCNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK001920GYCNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK003840GYCNN","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK007680GYCNE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000240GXPQT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000480GXPQU","SWKeyExpectedPath":"firmware:sd:sata"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"8ae279136d1146d9a07e0ced51a7a9cd"}]},{"ProductId":"3d004333c656491289fdf09d5881fcdd","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFPおよびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li><li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li><li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li></ul><p>&nbsp;<strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"7336381","DateModified":"2025-05-14T04:47:09","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/CP066568.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/KPE60X1GHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-16.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066568.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066568.scexe"],"MD5Sum":"9b19d6b4a5a22d2e3f3f2f83f09c9f42","Name":"firmware-hdd-54addf5312-HPK3-16.1.x86_64.rpm","Release":"2025-05-14T09:35:57","Revision":"P","SHA1Sum":"1bc9eb5ede6bb11353bb5369ada1f49b16abbc07","SHA256Sum":"127e0dfe6785bf319c90d12332e1ff73bda42dd28835a48b8cf238b606817c5a","Size":"6MB","TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"CP041698.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p><p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p><ul><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul><li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p><p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T05:25:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>直接接続されたNVMeファームウェアのフラッシュの表示メッセージを修正し、OSによるFWアクティベーションの結果を揃えます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a7dd9c9752714e15804cbe32077f1145"}]},{"ProductId":"dcf87aae93de4d649fef4547bffe751a","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX6デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"},{"Lang":"cn","Value":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"9055788","DateModified":"2025-06-16T05:17:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/CP067549.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw/fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw/fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw/fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067549.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067549.scexe"],"MD5Sum":"f5b1ae90013a04f8dfca19193553ac25","Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.18-1.1.x86_64.rpm","Release":"2025-06-16T10:13:39","Revision":"","SHA1Sum":"b5457812f0b8a70964aba59044b319ccffa13678","SHA256Sum":"3353502bdad982a07132e96921994d7fa300e1c15878693678cae43d6a686bff","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.18"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T11:48:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2026にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"1.0.17"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.18"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7dd0435c32a34e52a0679169b72dff45"}]},{"ProductId":"aedaa041caed4345872545de3f1efa40","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5694597","DateModified":"2025-05-14T07:46:47","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/CP066504.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/SAVGNSD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066504.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066504.scexe"],"MD5Sum":"d1ba8c7165b51f193ebeb9a9f5ced4b5","Name":"firmware-hdd-fa46c607d6-HPD5-6.1.x86_64.rpm","Release":"2025-05-14T12:34:58","Revision":"F","SHA1Sum":"4aa44228218a9ef6bd9ba6679d22d479224368ec","SHA256Sum":"5757d4d6b8d39a3e39d6a3e1574b51b3f67c106a4353ec153b417763b65b09c6","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP040294.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T19:33:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e4664ce7c3474991a0aa149dbbfcffa1"}]},{"ProductId":"672edcd2af9a4bd18876e5e3192cd831","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11817755","DateModified":"2025-05-14T21:30:08","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/CP067212.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/U40_3.50_04_17_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.50_2025_04_17-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067212.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067212.scexe"],"MD5Sum":"dbf17224e4ed1eefe5c6a8c3d3e86c22","Name":"firmware-system-u40-3.50_2025_04_17-2.1.x86_64.rpm","Release":"2025-05-15T02:21:04","Revision":"B","SHA1Sum":"cbc6af01e0260d5b1b976cc2f056055eabcdd974","SHA256Sum":"356091d3af3a5723f41a8fd2a1488b7ea2eace2663087fe5191d021b5f0dba60","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートする場合:<br /> <br />RPMパッケージをインストールします。<br />> rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />> rpm -qlp <filename>.rpm<br /> <br />前のステップで見たディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-15T02:17:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"389edd02a33740e8b575db43724c61eb"}]},{"ProductId":"5b36200ffa3640839369c39ca58c8134","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b584e5848","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b584e5a56","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58504141","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58504142","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b584e5844","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b584e5a51","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b584e5a52","Version":"HPS3"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_Micron_7450_M7450ALLHPS3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b584e5a54","Version":"HPS3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。VO000960KXNXD、VO001920KXNZQ、VO003840KXNZR、VO007680KXNZT、MO000800KXNXH、MO001600KXNZV、MO003200KXPAA、およびMO006400KXPAB"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; - Improvements to our out-of-band message handling to ensure robust device management capabilities<br />&nbsp;&nbsp;&nbsp; - Changes to improve our PCIe link compatibility as well as device reliability<br />&nbsp; &nbsp; -&nbsp;This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付：</strong><br />     HPS3<br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPS1<br /><strong>前のファームウェアバージョン：</strong><br />     HPS1<br /><strong>機能強化/新しい機能：</strong><br />      なし</p><p><strong>修正された問題点：</strong><br />    - 強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善<br />    - デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善<br />    - このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</p><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; - Improvements to our out-of-band message handling to ensure robust device management capabilities<br />&nbsp;&nbsp;&nbsp; - Changes to improve our PCIe link compatibility as well as device reliability<br />&nbsp; &nbsp; -&nbsp;This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2390411","DateModified":"2024-05-06T09:59:15","FileList":["Micron_7450_Micron_7450_M7450ALLHPS3.HPb","Micron_7450_Micron_7450_M7450ALLHPS3.xml","payload.json"],"MD5Sum":"df9258d8fb5d6e35159b805e0cd36109","Name":"Micron_7450_Micron_7450_M7450ALLHPS3.fwpkg","Release":"2024-05-16T00:00:00","Revision":"","SHA1Sum":"31f35f3c86a40970ac7189d3c9cb92013f86ac89","SHA256Sum":"1752964c42c72ea8a32b625c1aad585371ba2f0c2870694ca45be4e296236a3c","Size":"2MB","TargetGUIDs":["4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844","562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54"],"TypeOfChange":"1","Version":"HPS3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - VO000960KXNXD、VO001920KXNZQ、VO003840KXNZR、VO007680KXNZT、MO000800KXNXH、MO001600KXNZV、MO003200KXPAA、およびMO006400KXPAB"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VO001920KXNZQ","TargetGUID":"562340a5-304f-3130-3932-304b584e5a51","Type":"nvme"},{"Id":"VO003840KXNZR","TargetGUID":"562340a5-304f-3330-3834-304b584e5a52","Type":"nvme"},{"Id":"VO007680KXNZT","TargetGUID":"562340a5-304f-3730-3638-304b584e5a54","Type":"nvme"},{"Id":"MO000800KXNXH","TargetGUID":"4d2340a5-304f-3030-3830-304b584e5848","Type":"nvme"},{"Id":"MO001600KXNZV","TargetGUID":"4d2340a5-304f-3130-3630-304b584e5a56","Type":"nvme"},{"Id":"MO003200KXPAA","TargetGUID":"4d2340a5-304f-3330-3230-304b58504141","Type":"nvme"},{"Id":"MO006400KXPAB","TargetGUID":"4d2340a5-304f-3630-3430-304b58504142","Type":"nvme"},{"Id":"VO000960KXNXD","TargetGUID":"562340a5-304f-3030-3936-304b584e5844","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-07T09:26:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善</li><li>デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善</li><li>このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"cn"}],"Version":"HPS3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>強力なデバイス管理機能を確保するためのアウトオブバンドメッセージ処理の改善</li><li>デバイス管理機能の堅牢を確保するために、アウトオブバンドメッセージの改善</li><li>このファームウェアアップデートは、システムの相互運用性を向上させ、ドライブが応答しなくなる可能性のある特定のシナリオを防止するため、推奨されます。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improvements to our out-of-band message handling to ensure robust device management capabilities</li><li>Changes to improve our PCIe link compatibility as well as device reliability</li><li>This firmware update is recommended as it improves our system interoperability and prevents specific scenarios that could cause the drive to become unresponsive.</li></ul>","Lang":"cn"}],"Version":"HPS3"}],"SWKeys":[{"Name":"VO000960KXNXD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXNZQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXNZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXNZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO000800KXNXH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXNZV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPAA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPAB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"be4575b6b0d64fc097f43ac471267831"}]},{"ProductId":"057a33153b064c9280dd7da9d3d5a47a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNLおよびEG002400JWJNN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue. &nbsp; &nbsp;&nbsp;</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue. &nbsp; &nbsp;&nbsp;</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"3253008","DateModified":"2025-01-10T10:00:18","FileList":["cp065025.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEe0HPD5.REL"],"MD5Sum":"1da20c1dc078b63f9f42bc954a6c6bdb","Name":"cp065025.exe","Release":"2025-01-10T09:56:04","Revision":"E","SHA1Sum":"fc3a0011dbbb27a67f34ea4a8647460e46c754e1","SHA256Sum":"f6bfb2bda6942f676d146581dbf98ad6db4ad142459377dc19f6f94ffcc866e6","Size":"3MB","TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"EG002400JWJNN","TargetGUID":"452340a5-3047-3230-3430-304a574a4e4e","Type":"sas"},{"Id":"EG001800JWJNL","TargetGUID":"452340a5-3047-3130-3830-304a574a4e4c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:10:11","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Sever 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Sever 2025.</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0f9c20ff191f45069b5cd7ae80081d14"}]},{"ProductId":"703e98acf33d484a9d2825573e86e8c0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33608941","DateModified":"2025-04-18T13:04:22","FileList":["payload.json","U38_3.50_04_17_2025.signed.flash","U38_3.50_04_17_2025.xml"],"MD5Sum":"7e01613687eef562beeeb8d55783f0ce","Name":"U38_3.50_04_17_2025.fwpkg","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"fe5d90f42f793399f4adb061382dde7fdc1ff0a6","SHA256Sum":"8952dd23e4d43da85262d49e0b997514f1926651011bc9e56d724190b2ea5d08","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Creator Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">http://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"ja","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:59","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"0948e29c810e408f8db77388212bcaeb"}]},{"ProductId":"b3a8e7e2c4ea466a9b404955f474449e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"MinimumActiveVersion":"5.3.0","Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"cn","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の認証情報を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"9772488","DateModified":"2025-07-16T02:09:22","FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/b1a088135d75a28ea0885197acb8286e32bb7c","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"MD5Sum":"2f243b960b7c8003632d7859006456ef","Name":"sut-6.2.0-9.linux.x86_64.rpm","Release":"2025-07-16T07:05:07","Revision":"","SHA1Sum":"d50e276604f6ad472684fcfe00d9b65e78d81e20","SHA256Sum":"1d1687c569abf17af53bfac84952e6069a5b7816fb33dcfc2a5b6f77f67d0b4d","Size":"9MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.2.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"ja","Value":"<p>RPMパッケージをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。\"rpm -Uvh hpsut-XXX.x86_64.rpm\"とタイプしてインストールします。</p>"},{"Lang":"cn","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"cn","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Linux x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-01T17:01:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.1.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"6.2.0.0"}],"SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U77","Model":"HPE ProLiant Compute DL110 Gen12"},{"Family":"R13","Model":"HPE ProLiant Compute DL384 Gen12"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"cbdb18339b7f4044ab2b1a0bba104d6e"}]},{"ProductId":"72ce2dc2a1214941a11d7ccaace19196","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEAsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JWDFD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000JWDFD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000JWDFD Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"20422796","DateModified":"2025-03-07T06:36:30","FileList":["/CP065935_BUILD_4.data","/CP065935.vmexe64","/CP065935.vmfile","/CP065935_VMw.zip","/CP065935.xml","/payload.json","/CP065935_VMw.zip/index.xml","/CP065935_VMw.zip/vendor-index.xml","/CP065935_VMw.zip/metadata.zip","/CP065935_VMw.zip/vib20/CP065935/HPE_bootbank_CP065935_HPD4.4-1OEM.800.1.0.20613240.vib","/CP065935_VMw.zip/metadata.zip/vendor-index.xml","/CP065935_VMw.zip/metadata.zip/vmware.xml","/CP065935_VMw.zip/metadata.zip/vibs/CP065935-1224609892013420191.xml","/CP065935_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065935_HPD4.4-1OEM.800.1.0.20613240.xml"],"MD5Sum":"1442177146469bb6a02369ab2fed09a4","Name":"CP065935.zip","Release":"2025-03-07T06:35:46","Revision":"C","SHA1Sum":"cbd259e937977b295e45cb3fab6db1b632de81fc","SHA256Sum":"c32d1252d8f1c08af15887cf12c0dcd48098af60ef5f08b000fd8470aa6f8a36","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP065935","Version":"HPD4.4-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040682.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong><br /><u>Commands required to execute VIB file on ESXi&nbsp; 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></p><p>&nbsp;</p><p><strong>Additional information to execute VIB file.</strong><br /><u>Commands required to execute VIB file on ESXi&nbsp; 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JWDFDドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB012000JWDFD","TargetGUID":"4d2340a5-3042-3231-3030-304a57444644","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T10:52:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5f220474c8eb42dc950cba5f2954ae24"}]},{"ProductId":"8a5f6b85a2a94dc58e5d42c516c7060a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB016000JWXKH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB016000JWXKH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDC<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPDA<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul><p><strong>Known Issues:</strong></p><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19575513","DateModified":"2025-03-07T11:16:21","FileList":["/CP065940_BUILD_3.data","/CP065940.vmexe64","/CP065940.vmfile","/CP065940_VMw.zip","/CP065940.xml","/payload.json","/CP065940_VMw.zip/index.xml","/CP065940_VMw.zip/vendor-index.xml","/CP065940_VMw.zip/metadata.zip","/CP065940_VMw.zip/vib20/CP065940/HPE_bootbank_CP065940_HPDC.3-1OEM.800.1.0.20613240.vib","/CP065940_VMw.zip/metadata.zip/vendor-index.xml","/CP065940_VMw.zip/metadata.zip/vmware.xml","/CP065940_VMw.zip/metadata.zip/vibs/CP065940--2021015516232520248.xml","/CP065940_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065940_HPDC.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"063470b35ee44544ac2fc3ba3bc106a2","Name":"CP065940.zip","Release":"2025-03-07T11:15:37","Revision":"B","SHA1Sum":"5e3bcc2aa981a662f7ad4e5075d2f0c27588823c","SHA256Sum":"2136bfdb97680cbe69b0a2e08c5c01abd9f3acc2e092adcc9336638fede601e2","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC","VibList":[{"Name":"CP065940","Version":"HPDC.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041025.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB016000JWXKHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB016000JWXKH","TargetGUID":"4d2340a5-3042-3631-3030-304a57584b48","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:13:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このメンテナンスリビジョンにより、データの完全性が向上します。</li><li>このファームウェアにアップグレードしない場合のリスクは、特定のエラーやタイミング条件でデータが破損する可能性が高まることです。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This maintenance revision improves data integrity.</li><li>The risk of not upgrading to this firmware is the increased possibility of data corruption in certain error and timing conditions.</li></ul>","Lang":"cn"}],"Version":"HPDC"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDC"}],"SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6b0b91b47e2f4d9189480894f7b1ba61"}]},{"ProductId":"b2dec2e98a4f489c96311517a4bf5571","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2025用のドライバーを含みます。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2339504","DateModified":"2025-03-25T06:43:19","FileList":["cp066450.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"MD5Sum":"c34a92706d3d80de7810e52ddd23bfbe","Name":"cp066450.exe","Release":"2025-03-25T06:29:05","Revision":"","SHA1Sum":"b28eac6aa98ebd64d96245108ac6ad14004fb9c7","SHA256Sum":"724d34ff423c5ad06492140f239cdd74a23fdc76eedf4fd44cfd4b878290e711","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.1.26647.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2025"},{"Lang":"cn","Value":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1016","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1016159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1018","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101815900246","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T08:37:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>ホストシステムからファームウェアに割り当てられたメモリページ数 (4 KB) を表示する新しいカウンター\"Allocated Memory Pages\"を追加しました。</li><li>MlxNdPerfは複数のQPを使用した帯域幅テストをサポートするようになりました。</li><li>DevXインターフェイスでの動的ステアリングルール挿入のサポートが追加されました。</li></ul>","Fixes":"<ul><li>この製品では、複数のアダプターから同じVMにVFを割り当て、カウンターを照会し、1 つのアダプターからすべてのVFを削除すると、VF診断カウンターが表示されないという問題が修正されました。</li><li>この製品は、ポーリングによって間違ったリクエスト コンテキストが返されるまれなケースを修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added a new counter &quot;Allocated Memory Pages&quot; to show the number of memory pages (4KB) allocated to the firmware from the host system.</li><li>MlxNdPerf now supports bandwidth tests with multiple QPs.</li><li>Added support for dynamic steering rule insertion in DevX interface.</li></ul>","Fixes":"<ul><li>This product fixed an issue that prevented the VF diagnostic counters from being shown when assigned a VF from multiple adapters to the same VM, queried for counters and removed all VFs from one adapter.</li><li>This product fixed a rare case when polling returns wrong request context.</li></ul>","Lang":"cn"}],"Version":"24.10.26603.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"25.1.26647.0"}],"SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"96a211c9133b46ef81e135cbfa01d5a8"}]},{"ProductId":"6a4f9209b5474891beaf50886f41470e","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p71_PLDMoMCTP_8002003A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.71"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."},{"Lang":"ja","Value":"このパッケージには、Intel E810-XXVDA4T Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4T Gigabit Ethernet NIC firmware."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK NG Adapter for HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"},{"Lang":"ja","Value":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROMバージョン</th><th>NVMバージョン</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプターfor HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLK NGアダプターfor HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>NIC HIIメニュー（F9->システムユーティリティ->システム構成->\"NICを選択\"->ファームウェアイメージプロパティ）では、NVMバージョンは4.7と示されます</p><p>製品の詳細については、<a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a>にある最新のドキュメントを参照してください。</p><ul><li>FWをCVL4.71にアップグレードするには、最低限必要なFWバージョンはCVL4.2です。古いFWバージョンをご利用の場合は、中間のFWバージョンを追加でアップグレードしてください。<ul><li>例：CVL4.1-> CVL4.2(以降)-> CVL4.71</li></ul></li></ul>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p><table border=\"1\"><thead><tr><th>NIC</th><th>EEPROM ID</th><th>OROM Version</th><th>NVM Version</th></tr></thead><tbody><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr><tr><td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK NG Adapter for HPE</td><td>8002003A</td><td>1.3755.0</td><td>4.71</td></tr></tbody></table><p>In NIC HII menu(F9-&gt;System Utilities-&gt;System Configuration-&gt;&quot;Select the NIC&quot;-&gt;Firmware Image Properties), NVM Version shows 4.7</p><p>For more product details, please refer to the latest document in <a href=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\" id=\"menur20ej\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html\">https://www.intel.com/content/www/us/en/content-details/831604/intel-ethernet-controller-products-release-notes.html</a></p><ul><li>To upgrade FW to CVL4.71, the minimum required FW version is CVL4.2. Please upgrade an additional middle FW version if you are using old FW versions.<ul><li>e.g., CVL4.1-&gt;CVL4.2(or later)-&gt;CVL4.71</li></ul></li></ul>"}],"Files":[{"Bytes":"10522587","DateModified":"2025-04-01T06:29:42","FileList":["HPE_E810_XXV4T_O_SEC_4p71_PLDMoMCTP_8002003A.HPb","HPE_E810_XXV4T_O_SEC_4p71_PLDMoMCTP_8002003A.xml","payload.json"],"MD5Sum":"c5511819635072047e692e6ab7693512","Name":"HPE_E810_XXV4T_O_SEC_4p71_PLDMoMCTP_8002003A.fwpkg","Release":"2025-04-07T00:00:00","Revision":"","SHA1Sum":"59fd2f1a3ba16c1773bca7fa76daa1271974ec01","SHA256Sum":"2f7778745e73524b4b1fe0718d9eaddcf737c86c40a1e166bec513d485cad27b","Size":"10MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.71"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンを見つけてダウンロードするには、<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><a href=\"https://support.hpe.com/\">USB Key Creator Utility</a>（https://support.hpe.comで検索してダウンロード）を使用して、<strong>Service Pack for ProLiant</strong>をUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、認証情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul><p><strong><em>追加情報：</em></strong></p><ul><li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li><li><p>HPE Intel E810ベースのネットワークアダプターでは、ファームウェアのアップデートを試行した後にシステムを再起動する必要があります。システムを再起動せずにファームウェアを複数回アップデートすると、以前に試行したファームウェアのアップデートがキャンセルされる可能性があります。</p></li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See<a href=\"https://support.hpe.com/\">&nbsp;https://support.hpe.com</a>&nbsp;to find and&nbsp;download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility&nbsp;(</strong>find and&nbsp;download&nbsp;<a href=\"https://support.hpe.com/\">https://support.hpe.com</a>)</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li><li><p>HPE Intel E810-based network adapters require a system reboot after attempting the firmware update. Updating the firmware more than once without performing a system reboot may result in canceling the previous attempted firmware update.</p></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "},{"Lang":"ja","Value":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 MCLKアダプター "},{"Lang":"cn","Value":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:40:04","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>この製品は、速度がGen3にダウングレードされる可能性がある問題を修正します。</li><li>この製品は、RDE:MACAddressプロパティ がパッチされたときにEEPROMチェックサムエラーが原因でLinuxドライバーのロードに失敗する問題を修正します。</li><li>この製品は、NetworkDeviceFunctions設定でRDEパッチ操作を実行した後にNICが検出されない問題を修正します。</li><li>この製品は、RDE: Setting プロパティ (AutoSpeedNegotiationEnabled) によってプロパティ値がアップデートされず、コード400が返される問題を修正します。</li><li>この製品は、アダプターがパススルーとして構成されている場合に RDE が取得操作を実行できない問題を修正します。</li><li>この製品は、RDE プロパティ FlowControlConfiguration がTxに設定された後に、RDEプロパティ (FlowControlStatus) が正しいステータスを報告しない問題を修正します。</li><li>この製品は、AutoSpeedNegotiationEnabled プロパティでRDEパッチ操作が失敗する問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product fixes an issue where the speed may be downgraded to Gen3.</li><li>This product fixes an issue where the Linux driver fails to load due to an EEPROM checksum error when the RDE:MACAddress property is patched.</li><li>This product fixes an issue where the NIC is not detected after performing the RDE patch operation on NetworkDeviceFunctions settings.</li><li>This product fixes an issue where the RDE: Setting property (AutoSpeedNegotiationEnabled) does not cause the property value to update, returning a code 400.</li><li>This product fixes an issue where the RDE fails to perform the get operation when the adapter is configured as pass-through.</li><li>This product fixes an issue where the RDE property (FlowControlStatus) does not report the correct status after the RDE property FlowControlConfiguration is set to Tx.</li><li>This product fixes an issue where the RDE patch operation fails on the AutoSpeedNegotiationEnabled property.</li></ul>","Lang":"cn"}],"Version":"4.71"}],"SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"8771d53514e24352bb0b3a48756da845"}]},{"ProductId":"4e3802b484324394ada6924af481323b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2025で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1669496","DateModified":"2025-02-13T04:17:20","FileList":["cp065620.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"MD5Sum":"d16341da4137c2561b34c882bc4fe381","Name":"cp065620.exe","Release":"2025-02-13T04:03:10","Revision":"B","SHA1Sum":"759ef33e412c55eab4ed37a00cf6f6d550ffc2ae","SHA256Sum":"a54ac96230969fe4b205255df6016a32e5f36a8cb39c155f8abec4440257df30","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.15.302.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Microsoft Windows Server 2025"},{"Lang":"ja","Value":"Intel iceaドライバーfor Microsoft Windows Server 2025"},{"Lang":"cn","Value":"Intel icea Driver for Microsoft Windows Server 2025"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-11T08:01:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.302.0"},{"ReleaseNotes":[{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>初期バージョン。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Initial&nbsp;version.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.302.0"}],"SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"4af7309fa65f466d8f6f5288f4ba82a7"}]},{"ProductId":"a4ccd8709d044858ab5bf64233046176","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM1_1.46_B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"1.46"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains firmware for ProLiant Gen10Plus UBM1 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、ProLiant Gen10Plus UBM1ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains firmware for ProLiant Gen10Plus UBM1 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"57567","DateModified":"2022-08-07T12:23:38","FileList":["HPE_UBM1_1.46_B.HPb","HPE_UBM1_1.46_B.xml","payload.json"],"MD5Sum":"8733243bab6e28ed811793d02a7a122c","Name":"HPE_UBM1_1.46_B.fwpkg","Release":"2022-09-13T00:00:00","Revision":"B","SHA1Sum":"50f0dd4496c424a52d57dd0bc37c0a7a2a91350f","SHA256Sum":"ec4e698d31c1155c25ae81dce5204accaff8c1bb0776f7b67c34fa9196d77a1b","Size":"56KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901501000000"],"TypeOfChange":"1","Version":"1.46"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM1 Backplane PIC PLDM Firmware"},{"Lang":"ja","Value":"ファームウェアパッケージ - UBM1バックプレーンPIC PLDMファームウェア"},{"Lang":"cn","Value":"Firmware Package - UBM1 Backplane PIC PLDM Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901501000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2023-04-28T04:51:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.46"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>UBM FWPKGの初期バージョン。</li><li>RHEL9およびESXi8.0をサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Initial version for UBM FWPKG.</li><li>Support RHEL9 and ESXi8.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.46"}],"SWKeys":[{"Name":"UBM1PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"a663f1f50ce245ec806abddbf83cd919"}]},{"ProductId":"6c76dfc1e26441a48559e0f1bee2891e","Versions":[{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"cn","Value":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"Lang":"ja","Value":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5114056","DateModified":"2025-03-25T07:02:17","FileList":["Config.xml","cp066429.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"MD5Sum":"6a55d15616d867428d7d00865cce7529","Name":"cp066429.exe","Release":"2025-03-25T07:01:20","Revision":"S","SHA1Sum":"d6971cb6c829155f75bfd0c072141d80ca58c84b","SHA256Sum":"2eb5fdede335c79b8768891e2a7fdd91c95a43aa90e54665416ce76925bea69c","Size":"4MB","TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/tD6020 /v2.74 /iTormore-Release-2.74-build-001.bin /lD6020.log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":1200,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"ja","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"},{"Lang":"cn","Value":"<p><strong>Windows Smart Component Installation Instructions:</strong></p><p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p><p><strong>GUI Option:</strong></p><ol><li>Place the downloaded firmware package in a temporary directory.</li><li>Using Windows Explorer, navigate to the directory containing the download.</li><li>Double click the executable file.</li><li>Follow onscreen instructions.</li></ol><p><strong>CLI Option:</strong></p><p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p><p>&nbsp; &nbsp; &nbsp; &nbsp;</p><p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p><p><strong>Online:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li><li>Run the launch_sum.bat in the root of the ISO.</li><li>Follow the instructions on the screen.</li></ul><p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p><p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />-----------------------------------------------------------------------------<br /><strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br /><strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p><p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br /><strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"cn","Value":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"Lang":"ja","Value":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"2"},"SupportedDevices":[{"Id":"D6020","TargetGUID":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T06:14:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>以下の修正がこのリリースに含まれました:</strong></p><ul><li>gSEPモデルとSESデータベース内の温度センサーロジック</li><li>IOMが引き出されたときに、残っているIOMが正しくない異常温度を報告する</li></ul><p>このファームウェアに関する修正のリスト、拡張、既知の問題および回避方法については、<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>リリースノート</u></a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p><ul><li>Temperature sensors logic inside gSEP model and SES database</li><li>When an IOM is pulled the surviving IOM reports false critical temperatures</li></ul><p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v264146/20-D6020-Gen10RN274S_ED17.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>","Lang":"cn"}],"Version":"2.74"}],"SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"70986e1a9f7349b2945b7eec42f43797"}]},{"ProductId":"d0bba068f7ca4e978bcc6d2bf9e8abf7","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3231-3030-304a5945534e","Version":"HPD1"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3631-3030-304a59455643","Version":"HPD1"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3032-3030-304a59455644","Version":"HPD1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive model: MB12000JYESN, MB16000JYEVC and MB20000JYEVD"},{"Lang":"ja","Value":"このパッケージは、次のドライブモデルのファームウェアを提供します。MB12000JYESN、MB16000JYEVC、MB20000JYEVD"},{"Lang":"cn","Value":"This package provides firmware for the following drive model: MB12000JYESN, MB16000JYEVC and MB20000JYEVD"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Improve random read/write perfomance.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>リリースバージョンおよび/または日付:<br />     </strong>HPD1</p><p><strong>最新の推奨またはクリティカルバージョン：</strong><br />     なし</p><p><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題点：</strong></p><ul><li><p>ランダム読み取り/書き込みパフォーマンスを向上します。</p></li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li><p>Improve random read/write perfomance.</p></li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3770094","DateModified":"2025-02-19T17:33:16","FileList":["payload.json","Seagate_Summit_SUMMITSUSND1.HPb","Seagate_Summit_SUMMITSUSND1.xml"],"MD5Sum":"d628ca98fc4e6a75844234082bb1e5c9","Name":"Seagate_Summit_SUMMITSUSND1.fwpkg","Release":"2025-02-19T17:30:15","Revision":"B","SHA1Sum":"fe90fb65a6ded23d58c79b6996a5554c060508c8","SHA256Sum":"04df55ea3c44d6ead99950e975aa86a2e1da357b2b78bae2d6856fe04eb822ee","Size":"3MB","TargetGUIDs":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"TypeOfChange":"1","Version":"HPD1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[ファームウェア & OSソフトウェア]をクリックします -> [ファームウェアのアップデート]をクリックします -> [ファイルを選択]をクリックして、サポートされているPLDMファイルを参照します -> [フラッシュ]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li><li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"},{"Lang":"ja","Value":"ユニバーサルファームウェアパッケージforドライブ - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"},{"Lang":"cn","Value":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"MB12000JYESN","TargetGUID":"002340a5-424d-3231-3030-304a5945534e","Type":"sas"},{"Id":"MB16000JYEVC","TargetGUID":"002340a5-424d-3631-3030-304a59455643","Type":"sas"},{"Id":"MB20000JYEVD","TargetGUID":"002340a5-424d-3032-3030-304a59455644","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-13T19:07:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Improve random read/write perfomance.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>ランダム読み取り/書き込みパフォーマンスを向上します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Improve random read/write perfomance.</li></ul>","Lang":"cn"}],"Version":"HPD1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>このFWPKGからROMフラッシュウェイを削除します。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Remove ROM flash way from this FWPKG.</li></ul>","Lang":"cn"}],"Version":"HPD1"}],"SWKeys":[{"Name":"MB12000JYESN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB16000JYEVC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB20000JYEVD","SWKeyExpectedPath":"firmware:sd:sas"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"b9f6360d167c40e3b43a633519b19ce3"}]},{"ProductId":"6f10e85c0a8e4d0f99dcb8584f535fd3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD8"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD8"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Provides proactive protection against contamination built up on the media and air-bearing surface of the heads by increased routine &ldquo;sweeping&rdquo; of the media surface.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"5129702","DateModified":"2025-05-15T11:00:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/CP066519.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/TA14SXn0HPD8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066519.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066519.scexe"],"MD5Sum":"6db77a1c311426c2e42fe005e328f9ef","Name":"firmware-hdd-8d68452816-HPD8-6.1.x86_64.rpm","Release":"2025-05-15T15:48:04","Revision":"F","SHA1Sum":"2b6e68cd1cb5b44081ebe2dc52113e8e20429bf1","SHA256Sum":"326b5440f32dbd9df2e3b653a056fa227573cea031a0a52483aacced2efdbecf","Size":"4MB","TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"CP041672.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"EH000300JWHPL","TargetGUID":"452340a5-3048-3030-3330-304a5748504c","Type":"sas"},{"Id":"EH000600JWHPN","TargetGUID":"452340a5-3048-3030-3630-304a5748504e","Type":"sas"},{"Id":"EH000900JWHPP","TargetGUID":"452340a5-3048-3030-3930-304a57485050","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T06:09:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6c8d6b7797334eaaa502bcaeec4e4cac"}]},{"ProductId":"809cff8704ac44759685c033bb7b76d3","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>&nbsp; &nbsp;Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"20249536","DateModified":"2025-03-06T09:39:33","FileList":["/CP065999_BUILD_5.data","/CP065999.vmexe64","/CP065999.vmfile","/CP065999_VMw.zip","/CP065999.xml","/payload.json","/CP065999_VMw.zip/index.xml","/CP065999_VMw.zip/vendor-index.xml","/CP065999_VMw.zip/metadata.zip","/CP065999_VMw.zip/vib20/CP065999/HPE_bootbank_CP065999_HPD2.5-1OEM.800.1.0.20613240.vib","/CP065999_VMw.zip/metadata.zip/vendor-index.xml","/CP065999_VMw.zip/metadata.zip/vmware.xml","/CP065999_VMw.zip/metadata.zip/vibs/CP065999--3281436684859785458.xml","/CP065999_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065999_HPD2.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"2180b2c156cc949677ae71714e03f47b","Name":"CP065999.zip","Release":"2025-03-06T09:38:42","Revision":"J","SHA1Sum":"f6a3ab65d0ce979f467b5573f3bcb81f56567087","SHA256Sum":"3e48199525870591afd12472395d71804a90d5aa4d756cdb9a0980e5973792ca","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065999","Version":"HPD2.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP065999.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for ESXi - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB014000JWRTH","TargetGUID":"4d2340a5-3042-3431-3030-304a57525448","Type":"sas"},{"Id":"MB012000JWRTF","TargetGUID":"4d2340a5-3042-3231-3030-304a57525446","Type":"sas"},{"Id":"MB010000JWRTE","TargetGUID":"4d2340a5-3042-3031-3030-304a57525445","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T14:49:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"fb0ba8f67f8f42d3ba9f214d072fe390"}]},{"ProductId":"6522bf51105244bfa55540a1e824854d","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component updates the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"このコンポーネントは、HPE Gen10 PlusサーバーのHPE Gen10 Plus Innovation Engine Firmwareをアップデートします。"},{"Lang":"cn","Value":"This component updates the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9043512","DateModified":"2025-02-10T06:00:21","FileList":["cp051643.compsig","cp051643.zip","cp065582.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"4bd3cac884529fda6692bdc996d939e7","Name":"cp065582.exe","Release":"2025-02-10T05:58:21","Revision":"E","SHA1Sum":"8299919327eb6624edec85af61ef4752012819fc","SHA256Sum":"0d3c43ceb6e03cce74872b26329bef306db21e40693d4c4462fc1081b7391df8","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br /> </p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Windows x64 - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T05:42:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(C) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision C if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p><p>Ver 1.0.0.22(C)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver 1.0.0.22と同等です。ファームウェアをバージョン1.0.0.22にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョンCにアップグレードする必要はありません。</p><p><strong>ファームウェアの依存関係:</strong></p><p> なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(C) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision C if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(E) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(E) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 1.0.0.22(E) contains updates to the firmware packaging and is functionally equivalent to ver. 1.0.0.22. It is not necessary to upgrade with Revision E if a previous component revision was used to upgrade the firmware to version 1.0.0.22.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"1.0.0.22"}],"SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"9b98028398924bcd9dbf622b9fa4b86c"}]},{"ProductId":"8484f11834644aea8a2a14d1d0d58403","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"ja","Value":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."},{"Lang":"cn","Value":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2022 and Microsoft Windows Server 2025."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This component contains the following drivers:</p><ul><li>Windows qevbd Driver is 8.72.21.0</li><li>Windows qend Driver is 8.72.21.0</li><li>Windows qefcoe Driver is 8.70.3.0</li><li>Windows qxdiag Driver is 8.14.0.0</li><li>Windows qeois Driver is 8.70.2.0</li></ul>"},{"Lang":"ja","Value":"<p>This component contains the following drivers:</p><ul><li>Windows qevbd Driver is 8.72.21.0</li><li>Windows qend Driver is 8.72.21.0</li><li>Windows qefcoe Driver is 8.70.3.0</li><li>Windows qxdiag Driver is 8.14.0.0</li><li>Windows qeois Driver is 8.70.2.0</li></ul>"},{"Lang":"cn","Value":"<p>This component contains the following drivers:</p><ul><li>Windows qevbd Driver is 8.72.21.0</li><li>Windows qend Driver is 8.72.21.0</li><li>Windows qefcoe Driver is 8.70.3.0</li><li>Windows qxdiag Driver is 8.14.0.0</li><li>Windows qeois Driver is 8.70.2.0</li></ul>"}],"Files":[{"Bytes":"6500104","DateModified":"2025-02-13T07:00:22","FileList":["cp064337.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"MD5Sum":"03de71dd33ed734bcc82457ada72d1d7","Name":"cp064337.exe","Release":"2025-02-13T06:47:07","Revision":"","SHA1Sum":"d023a67ec4c379c441f4b64cae5239643697bf34","SHA256Sum":"c7b21f45024e3e90b4250af46286b68f6789031ffd2a4f6aaee8ae7288e7d1c4","Size":"6MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"Lang":"ja","Value":"Marvell FastLinQ 10/25/50 GbEドライバー for Windows Server x64 Edition"},{"Lang":"cn","Value":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770070","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770069","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770068","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770071","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770072","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770074","Type":"pci","Ven":"1077"},{"Dev":"8090","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-809010770073","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-12-04T04:03:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product corrects an issue which Windows Server 2022 crashes when system has high number of logical processors.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、システムに多数の論理プロセッサーがある場合にWindows Server 2022がクラッシュする問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product corrects an issue which Windows Server 2022 crashes when system has high number of logical processors.</p>","Lang":"cn"}],"Version":"8.72.15.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"8.72.21.0"}],"SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"255c9aae8aa540dd8a906a5a449031e4"}]},{"ProductId":"65980a419afd45d6b2067bb6166a4282","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、VO015360KYDNB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;&nbsp;VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK6<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK5<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong>&nbsp;</p><ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNB ドライブ<br /><br /><strong>リリースバージョンおよび/または日付:</strong><br />      HPK6<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />      HPK5<br /><br /><strong>前のファームウェアバージョン：</strong><br />      HPK5<br /><br /><strong>ファームウェアの依存関係：</strong><br />      なし</p><p><strong>機能強化/新しい機能：</strong></p><p>      なし</p><p><strong>修正された問題：</strong> </p><ul><li>以前のファームウェアバージョンHPK5では、修正不可能なマシンチェック例外 (UMCE) が発生する可能性があります。ファームウェアバージョンを少なくともHPK6へアップデートすることが推奨されます。</li></ul><p><strong>既知の問題点：</strong><br />      なし</p>"}],"Files":[{"Bytes":"22542855","DateModified":"2025-03-06T20:13:22","FileList":["/CP065946_BUILD_9.data","/CP065946.vmexe64","/CP065946.vmfile","/CP065946_VMw.zip","/CP065946.xml","/payload.json","/CP065946_VMw.zip/index.xml","/CP065946_VMw.zip/vendor-index.xml","/CP065946_VMw.zip/metadata.zip","/CP065946_VMw.zip/vib20/CP065946/HPE_bootbank_CP065946_HPK6.9-8.0.0.20613240.vib","/CP065946_VMw.zip/metadata.zip/vendor-index.xml","/CP065946_VMw.zip/metadata.zip/vmware.xml","/CP065946_VMw.zip/metadata.zip/vibs/CP065946-5694786743774334663.xml","/CP065946_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065946_HPK6.9-8.0.0.20613240.xml"],"MD5Sum":"a728e2595af7a6eb83262ef33d7faf80","Name":"CP065946.zip","Release":"2025-03-06T20:12:36","Revision":"B","SHA1Sum":"bc94554e0bcaa09ceeb705005715b6010158ea17","SHA256Sum":"58ff533c44fc939fe0551c242b5628c862dfcbd6dd5afa78b783a77b31a0e039","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"2","Version":"HPK6","VibList":[{"Name":"CP065946","Version":"HPK6.9-8.0.0.20613240"}]}],"Installation":{"Command":"CP040631.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi  -  VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001920KYDMT、VO003840KYDMV、MO001600KYDMU、MO003200KYDNC、MO006400KYDND、VO007680KYDNA、およびVO015360KYDNBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO001920KYDMT","TargetGUID":"562340a5-304f-3130-3932-304b59444d54","Type":"nvme"},{"Id":"VO003840KYDMV","TargetGUID":"562340a5-304f-3330-3834-304b59444d56","Type":"nvme"},{"Id":"MO001600KYDMU","TargetGUID":"4d2340a5-304f-3130-3630-304b59444d55","Type":"nvme"},{"Id":"MO006400KYDND","TargetGUID":"4d2340a5-304f-3630-3430-304b59444e44","Type":"nvme"},{"Id":"VO015360KYDNB","TargetGUID":"562340a5-304f-3531-3336-304b59444e42","Type":"nvme"},{"Id":"VO007680KYDNA","TargetGUID":"562340a5-304f-3730-3638-304b59444e41","Type":"nvme"},{"Id":"MO003200KYDNC","TargetGUID":"4d2340a5-304f-3330-3230-304b59444e43","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:31:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA will published later at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアバージョンHPK5では、修正不可能なマシンチェック例外 (UMCE) が発生する可能性があります。ファームウェアバージョンを少なくともHPK6へアップデートすることが推奨されます。</li><li>詳しくは、CAが後で次のURLで公開されます。<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a>を参照してください。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Previous firmware version HPK5 may cause Uncorrectable Machine Check Exception (UMCE) to occur. It is recommended to update firmware version to HPK6.</li><li>For more information, CA will published later at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us\" id=\"menur8o\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=a00142315en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00142315en_us</a></li></ul>","Lang":"cn"}],"Version":"HPK6"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK6"}],"SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"a0bbf3db79104da6bc975c6db1959f9d"}]},{"ProductId":"63a556e6179b4101ae6472eac493f29b","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - Storage Fibre Channel"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネル"},{"Lang":"cn","Value":"软件 - 存储光纤通道"},{"Lang":"en","Value":"Software - Storage Fibre Channel HBA"},{"Lang":"ja","Value":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"Lang":"cn","Value":"软件 - 存储光纤通道 HBA"}],"Description":[{"Lang":"en","Value":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Linux operating systems."},{"Lang":"cn","Value":"该软件包提供的套件，在 Linux 操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"Lang":"ja","Value":"このパッケージは、LinuxオペレーティングシステムでEmulexファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"25064","DateModified":"2025-04-23T09:24:23","FileList":["./opt/hpe/elx_smartsan/SmartSAN.sh","./opt/hpe/elx_smartsan/elx_ss_enablement","./opt/hpe/elx_smartsan/readme.txt","./usr/share/smartupdate/hpe-emulex-smartsan-enablement-kit/component.xml"],"MD5Sum":"7ad7d1ffb26c311fe7392141ad5b5384","Name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","Release":"2025-04-23T09:21:43","Revision":"r","SHA1Sum":"30ca4f09151434c1b9045431c3c2ab46c2a9e594","SHA256Sum":"b98bd24477ac35a1c5a78f39078ac50bbf4c8dc71ed02a9bc099cd6e8b580d81","Size":"24KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dd508ef"],"TypeOfChange":"0","Version":"1.0.0.0-4"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p><p style=\"margin-left:40px\">To uninstall the Emulex Smart SAN enablement RPM use the following command:</p><p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-&lt;version&gt;.noarch.rpm</p><p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p><p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-emulex-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm</p><p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p><p style=\"margin-left:40px\">&nbsp;</p>"},{"Lang":"ja","Value":"<p>SmartSANは64ビット固有のキットです。 このコンポーネントをインストールする前に以前のキットをアンインストールすることをお勧めします。</p><p style=\"margin-left:40px\">Emulex Smart SANイネーブルメントRPMをアンインストールするには、次のコマンドを使用します：</p><p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-<version>.noarch.rpm</p><p>これは構成可能コンポーネントです。  Smart SAN機能を有効/無効にするための構成ファイルが必要です。  実行される構成がない場合は、現在のSmart SANステータスが提示され、実行が完了します。  それ以上のアクションは行われません。</p><p> </p><p>構成可能コンポーネントについて詳しくは、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00106063en_us\"><em>Smart Update Managerユーザーガイド</em></a>を参照してください。</p><p> </p><p><strong>HPE Service Pack for ProLiantの外部コンポーネントの実行</strong>:</p><p style=\"margin-left:40px\">1. システム管理者（root）としてログインします。</p><p style=\"margin-left:40px\">2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p style=\"margin-left:40px\">3. インストールするには、プロンプトで以下のコマンドを入力してください：<br />                    # rpm -ivh hpe-emulex-smartsan-enablement-kit-<version>.x86_64.rpm<br />                    例：# rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm</p><p style=\"margin-left:40px\">4.  インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />                    Installation complete</p><p style=\"margin-left:40px\"> </p>"},{"Lang":"cn","Value":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p><p style=\"margin-left:40px\">To uninstall the Emulex Smart SAN enablement RPM use the following command:</p><p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-&lt;version&gt;.noarch.rpm</p><p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p><p>&nbsp;</p><p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p><p>&nbsp;</p><p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p><p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p><p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-emulex-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm</p><p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p><p style=\"margin-left:40px\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Emulex Smart SAN Enablement Kit for Linux"},{"Lang":"cn","Value":"Linux版SmartSAN SmartSAN支持套件"},{"Lang":"ja","Value":"HPE Emulex Smart SAN イネーブルメントキット（Linux）"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-23T09:14:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.0-4</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"en"},{"Enhancements":"<p>バージョン1.0.0.0-4にアップデートしました</p><p>このコンポーネントはFIPSが有効になっています。</p>","Fixes":"<p>このコンポーネントはFIPSが有効になっています。</p>","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.0-4</p><p>This Component is FIPs enabled.</p>","Fixes":"<p>This Component is FIPs enabled.</p>","Lang":"cn"}],"Version":"1.0.0.0-4"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to version 1.0.0.0-4</p><p>&nbsp;</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Updated to version 1.0.0.0-4</p><p>&nbsp;</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to version 1.0.0.0-4</p><p>&nbsp;</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.0.0-4"}],"SWKeys":[{"Name":"hpe-emulex-smartsan-enablement-kit","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"ff883fa218c0497fa594f3cddcc1925c"}]},{"ProductId":"7004592a3bf74fab99a6fe756662ebbc","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名：</strong><br />     オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC、およびMO001920JWWWVドライブ</p><p><strong>リリースバージョンおよび/または日付：</strong><br />     HPDB<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     HPD9<br /><br /><strong>前のファームウェアバージョン：</strong><br />     HPD9<br /><br /><strong>ファームウェアの関連性：</strong><br />     なし</p><p><strong>機能強化/新しい機能：</strong></p><p>     なし</p><p><strong>修正された問題点：</strong></p><ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul><p><strong>既知の問題点：</strong><br />     なし</p>"}],"Files":[{"Bytes":"18045095","DateModified":"2025-03-06T05:05:35","FileList":["/CP065950_BUILD_5.data","/CP065950.vmexe64","/CP065950.vmfile","/CP065950_VMw.zip","/CP065950.xml","/payload.json","/CP065950_VMw.zip/index.xml","/CP065950_VMw.zip/vendor-index.xml","/CP065950_VMw.zip/metadata.zip","/CP065950_VMw.zip/vib20/CP065950/HPE_bootbank_CP065950_HPDB.5-1OEM.800.1.0.20613240.vib","/CP065950_VMw.zip/metadata.zip/vendor-index.xml","/CP065950_VMw.zip/metadata.zip/vmware.xml","/CP065950_VMw.zip/metadata.zip/vibs/CP065950-8875195631491333131.xml","/CP065950_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065950_HPDB.5-1OEM.800.1.0.20613240.xml"],"MD5Sum":"6ba4459d7b8d07843da3fef91dfbb464","Name":"CP065950.zip","Release":"2025-03-06T05:04:51","Revision":"C","SHA1Sum":"e506eae6c88f5f129e28beb29f16f9696ebe783c","SHA256Sum":"c4d3963209461f270abb33fab52498b928ed325307e1208f629e00fb1792ba03","Size":"17MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP065950","Version":"HPDB.5-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040758.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Ensure that CPxxxxxx.vmexe64 &nbsp;is executable by using the command:</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives"},{"Lang":"ja","Value":"オンライン HDD/SSDフラッシュコンポーネント for VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO007680JWTBP","TargetGUID":"562340a5-304f-3730-3638-304a57544250","Type":"sas"},{"Id":"MO006400JWTCD","TargetGUID":"4d2340a5-304f-3630-3430-304a57544344","Type":"sas"},{"Id":"VO003840JWTBN","TargetGUID":"562340a5-304f-3330-3834-304a5754424e","Type":"sas"},{"Id":"MO003200JWTBU","TargetGUID":"4d2340a5-304f-3330-3230-304a57544255","Type":"sas"},{"Id":"EO003200JWTCC","TargetGUID":"452340a5-304f-3330-3230-304a57544343","Type":"sas"},{"Id":"VO001920JWTBL","TargetGUID":"562340a5-304f-3130-3932-304a5754424c","Type":"sas"},{"Id":"MO001600JWTBT","TargetGUID":"4d2340a5-304f-3130-3630-304a57544254","Type":"sas"},{"Id":"EO001600JWTCB","TargetGUID":"452340a5-304f-3130-3630-304a57544342","Type":"sas"},{"Id":"VO000960JWTBK","TargetGUID":"562340a5-304f-3030-3936-304a5754424b","Type":"sas"},{"Id":"MO000800JWTBR","TargetGUID":"4d2340a5-304f-3030-3830-304a57544252","Type":"sas"},{"Id":"EO000800JWTCA","TargetGUID":"452340a5-304f-3030-3830-304a57544341","Type":"sas"},{"Id":"MO000400JWTBQ","TargetGUID":"4d2340a5-304f-3030-3430-304a57544251","Type":"sas"},{"Id":"EO000400JWTBV","TargetGUID":"452340a5-304f-3030-3430-304a57544256","Type":"sas"},{"Id":"MO001920JWWWV","TargetGUID":"4d2340a5-304f-3130-3932-304a57575756","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T11:36:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPDB"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDB"}],"SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5cc55e8f72054302a6d1bd6d2b2ec798"}]},{"ProductId":"3d4b3948a2e7454589365f36eee4d988","Versions":[{"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_PM9A3M2HPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584c5846","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This package provides firmware for the following drive models: VR000480KXLXF"},{"Lang":"ja","Value":"This package provides firmware for the following drive models: VR000480KXLXF"},{"Lang":"cn","Value":"This package provides firmware for the following drive models: VR000480KXLXF"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Enhancements/New Features:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><strong>Problems Fixed:</strong><br />&nbsp;&nbsp;&nbsp; Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3<br /><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3163589","DateModified":"2024-07-09T02:54:18","FileList":["payload.json","Samsung_PM9A3_PM9A3M2HPK3.HPb","Samsung_PM9A3_PM9A3M2HPK3.xml"],"MD5Sum":"02e7ad360d1e91ff43081a6bb2fab328","Name":"Samsung_PM9A3_PM9A3M2HPK3.fwpkg","Release":"2024-07-09T02:50:40","Revision":"","SHA1Sum":"13d1773a50dc16506cbef5daa8f2388ff974e5e6","SHA256Sum":"e14e19bd5c454d0ca46cd81cf97ad2c58a9f13fc434fd6a69ea7cfc30b35a789","Size":"3MB","TargetGUIDs":["562340a5-3052-3030-3438-304b584c5846"],"TypeOfChange":"1","Version":"HPK3"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"ja","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li><li>Reboot the server for the firmware update to take effect.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Universal Firmware Package for Drives -  VR000480KXLXF"},{"Lang":"ja","Value":"Universal Firmware Package for Drives -  VR000480KXLXF"},{"Lang":"cn","Value":"Universal Firmware Package for Drives -  VR000480KXLXF"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Id":"VR000480KXLXF","TargetGUID":"562340a5-3052-3030-3438-304b584c5846","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-08-09T00:58:37","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Firmware maintenance release of&nbsp;Samsung M.2 NVMe SSD with HPK3</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VR000480KXLXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc","Uefi"],"VersionId":"3bf954c2f143454a838399358e12d303"}]},{"ProductId":"169b01f1c4c245bc854a8424af9a5f85","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11584896","DateModified":"2025-04-18T11:33:45","FileList":["cp066807.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_3.50_04_17_2025.signed.flash"],"MD5Sum":"9fa3d1994cf28d871165bfa3dfb19533","Name":"cp066807.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"0266f6cf30056c5bfb4e496f81eada9ab6b3300e","SHA256Sum":"73986cedccfb9697732a6505b40552ceadd7bdb19954930c59ca0012a4a93d8b","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"add6864c09a343f5bc05b5ba4cc7815c"}]},{"ProductId":"7d855090560e4f85994eaba25e5477a5","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KWVBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b57564252","Version":"HPK3"},{"DeviceName":"VO001920KWVBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564254","Version":"HPK3"},{"DeviceName":"VO003840KWVBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD5ALSHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564255","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960KWVBR, VO001920KWVBT and VO003840KWVBU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p><p><strong>Problems Fixed:</strong></p><ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong></p><p>&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"19366080","DateModified":"2025-03-06T06:50:39","FileList":["/CP065969_BUILD_7.data","/CP065969.vmexe64","/CP065969.vmfile","/CP065969_VMw.zip","/CP065969.xml","/payload.json","/CP065969_VMw.zip/index.xml","/CP065969_VMw.zip/vendor-index.xml","/CP065969_VMw.zip/metadata.zip","/CP065969_VMw.zip/vib20/CP065969/HPE_bootbank_CP065969_HPK3.7-1OEM.800.1.0.20613240.vib","/CP065969_VMw.zip/metadata.zip/vendor-index.xml","/CP065969_VMw.zip/metadata.zip/vmware.xml","/CP065969_VMw.zip/metadata.zip/vibs/CP065969--8178915530695768403.xml","/CP065969_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065969_HPK3.7-1OEM.800.1.0.20613240.xml"],"MD5Sum":"3dc147479525ca2ed6e517173c976ac4","Name":"CP065969.zip","Release":"2025-03-06T06:49:48","Revision":"B","SHA1Sum":"bc970e6f5ed757b027270f8877ca8c6705778c8c","SHA256Sum":"4f6bfbc7ae7f3e72daf74bee8481be50b3ad095984f0442bfe9c291092e09207","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b57564252","562340a5-304f-3130-3932-304b57564254","562340a5-304f-3330-3834-304b57564255"],"TypeOfChange":"1","Version":"HPK3","VibList":[{"Name":"CP065969","Version":"HPK3.7-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP040631.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe64&nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>To update firmware from VMware ESXi 7.x operating system on target server:</strong></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Ensure that CPXXXXXX.vmexe64&nbsp;is executable by using the command:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe64</p><ul style=\"list-style-type:square\"><li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe64</li><li>Follow the directions given by the Smart Component.</li><li>Logout</li><li>Disable Tech Support Mode on the ESXi host.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0/8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi  - VO000960KWVBR, VO001920KWVBT and VO003840KWVBU Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KWVBR、VO001920KWVBT、およびVO003840KWVBUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO000960KWVBR","TargetGUID":"562340a5-304f-3030-3936-304b57564252","Type":"nvme"},{"Id":"VO001920KWVBT","TargetGUID":"562340a5-304f-3130-3932-304b57564254","Type":"nvme"},{"Id":"VO003840KWVBU","TargetGUID":"562340a5-304f-3330-3834-304b57564255","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:38:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>以前のファームウェアからの修正を導入するためのメンテナンスファームウェアリリース。</li><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Maintenance firmware release to introduce fixes from previous firmware.</li><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"VO000960KWVBR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KWVBT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KWVBU","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0f84dd3049c040b6bc5ce806d58746c4"}]},{"ProductId":"c4ef0470aa934a20948f1a88d8eff26d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJNドライブ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD5</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD4</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD4<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix for V6 Read disturb issue (which might have caused data integrity issue) and other issues.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5309362","DateModified":"2025-05-14T05:55:22","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/CP066525.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066525.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066525.scexe"],"MD5Sum":"ff8595ee795a3bed0516fdca431c9ca7","Name":"firmware-hdd-35fd24601f-HPD5-5.1.x86_64.rpm","Release":"2025-05-14T10:43:34","Revision":"E","SHA1Sum":"6a87c9b07c0e85450b6c224cfe8841312597d851","SHA256Sum":"70fe1c2944108f41bd7cfe2aea85f64882f95ea97fbbb638177f79e5ea08d27a","Size":"5MB","TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"Installation":{"Command":"CP043252.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p><ul><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p><ul><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p>Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p>画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJLおよびVO015360JWZJNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"VO015360JWZJN","TargetGUID":"562340a5-304f-3531-3336-304a575a4a4e","Type":"sas"},{"Id":"VO007680JWZJL","TargetGUID":"562340a5-304f-3730-3638-304a575a4a4c","Type":"sas"},{"Id":"VO003840JWZJK","TargetGUID":"562340a5-304f-3330-3834-304a575a4a4b","Type":"sas"},{"Id":"VO001920JWZJH","TargetGUID":"562340a5-304f-3130-3932-304a575a4a48","Type":"sas"},{"Id":"VO000960JWZJF","TargetGUID":"562340a5-304f-3030-3936-304a575a4a46","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-26T09:14:43","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f1052c1e2d8d44e28000054f6b96a70d"}]},{"ProductId":"6e4df08455db4ce3a3b07b6eecea6280","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."},{"Lang":"ja","Value":"Agentless Management Service（AMSD）は、Integrated Lights Out 5、6および7（iLO 5、6および7）内蔵ヘルスおよびアラートのサポートを提供します。"},{"Lang":"cn","Value":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 and 6 (iLO 5, 6 and 7) Embedded Health and Alerting."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7402758","DateModified":"2025-07-29T01:41:20","FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/24","./usr/lib/.build-id/24/1919fca811eeec21f6f2499229398693da6648","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/268551c3e268b716e0279e9d43f54ebade6a44","./usr/lib/.build-id/3a/268551c3e268b716e0279e9d43f54ebade6a44.1","./usr/lib/.build-id/77","./usr/lib/.build-id/77/e0a7a60ab0dd8bd3a520610a3116f4bd03434a","./usr/lib/.build-id/77/e0a7a60ab0dd8bd3a520610a3116f4bd03434a.1","./usr/lib/.build-id/87","./usr/lib/.build-id/87/c1a1e0abdd03922b90dd2e01fda5ccbd5674bb","./usr/lib/.build-id/87/c1a1e0abdd03922b90dd2e01fda5ccbd5674bb.1","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/4dcdd1cc2981abef6cf6a11683a3aebe476b97","./usr/lib/.build-id/b9/4dcdd1cc2981abef6cf6a11683a3aebe476b97.1","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/be11b27ded1f600caf78c25db1924d52b79fab","./usr/lib/.build-id/d0/be11b27ded1f600caf78c25db1924d52b79fab.1","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/742fec2d807a59f5956f784d3e40381f1afb66","./usr/lib/.build-id/ee","./usr/lib/.build-id/ee/0a669d796bd7d39224f3c27109d14ab0bcf447","./usr/lib/.build-id/ee/0a669d796bd7d39224f3c27109d14ab0bcf447.1","./usr/lib/.build-id/f9","./usr/lib/.build-id/f9/60cc398df917bdc983f5e14bb3d8da344788ca","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"MD5Sum":"a5c8c2951f45c3e2207b537a9a1a3eac","Name":"amsd-4.2.0-2039.3.rhel9.x86_64.rpm","Release":"2025-07-29T06:32:29","Revision":"","SHA1Sum":"c87a11755d2b0e89a17fe081e20c6a68184e630f","SHA256Sum":"92e7ad31dc83848c181b0f0396b5b1b3835d416cf06f5d30ab37789ffd6f77df","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"4.2.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>HPE servers with iLO 7:</strong></p><p>On HPE Gen12 servers with iLO7, HPE Agentless Management Service(AMS) uses HPE iLO Virtual NIC (VNIC) to communicate with iLO. For communication using VNIC, an application account in iLO needs to be created. As part of AMS installation, the application account can be generated and the same will be stored securely in the system TPM. &nbsp;This is a one-time configuration.&nbsp;<br />&nbsp;<br />Alternately application can be used without creating an application account. In this case, iLO credentials must be specified (using amscli) every time the OS or AMS restarts.</p><p><strong>Installation methods:</strong><br />&nbsp;<br />Method 1: Non interactive installation<br />&nbsp;Login as the system administrator (root), download the RPM and install_ams.sh to a directory on your hard drive and change to that directory.</p><ul><li>ILO_USERNAME=&lt;iLO_username&gt; ILO_PASSWORD=&lt;iLO_password&gt; rpm -ivh amsd-&lt;version&gt;.rpm</li></ul><p>As part of the installation process, an application account will be created. If the specified iLO credentials are incorrect or if there are any VNIC-related issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.&nbsp;<br />&nbsp;&nbsp;<br />Method 2: Using rpm command<br />To install the package, type:</p><ul><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul><p>During the installation process, you will be prompted to confirm the creation of an application account. If you choose to create the application account during installation, you must specify the iLO username and password. If the provided iLO credentials are incorrect or if there are any VNIC issues, the application account creation will fail. In such cases, manually create the application account post installation using the amscli command.<br />&nbsp;<br />If you choose not to create application account during the installation process, you can create application account post installation using amscli command.&nbsp;<br />&nbsp;<br />To check whether the package is loaded properly, type:</p><ul><li>systemctl status amsd</li><li>systemctl status smad</li></ul><p>Additional help is available by typing:</p><ul><li>man amsd</li></ul><p><strong>Using amscli to create application account:</strong><br />&nbsp;<br />If the creation of application account fails during installation process, you can use amscli command to create application account post installation. Type the following command:</p><ul><li>&nbsp;amscli appaccount create -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;<br /><strong>Using amscli to specify iLO credentials (no-application account method):</strong><br />&nbsp;<br />If you choose not to create an application account, you must specify&nbsp;iLO credentials every time the OS or application restarts. Type the following command:</p><ul><li>amscli set -u &lt;ilo_username&gt; -p &lt;ilo_password&gt;</li></ul><p>&nbsp;</p><p><strong>HPE servers with iLO 5 and iLO 6:</strong></p><p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p><ul><li>To install the package type:<ul style=\"list-style-type:circle\"><li>rpm -Uvh amsd-&lt;version&gt;.rpm</li></ul></li><li>To check whether the package is loaded properly type:<ul style=\"list-style-type:circle\"><li>systemctl status amsd</li><li>systemctl status smad</li></ul></li><li>Additional help is available by typing:<ul style=\"list-style-type:circle\"><li>man amsd</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 9 Server"},{"Lang":"ja","Value":"Agentless Management Service (iLO 5、iLO 6およびiLO 7) for Red Hat Enterprise Linux 9 Server"},{"Lang":"cn","Value":"Agentless Management Service (iLO 5, iLO 6 and iLO 7) for Red Hat Enterprise Linux 9 Server"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"},{"Dev":"3306","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159003ba","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"03BA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159003ba","Type":"pci","Ven":"103c"},{"Dev":"3306","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330615903307","Type":"pci","Ven":"103c"},{"Dev":"3307","SubDev":"3307","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-330715903307","Type":"pci","Ven":"103c"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-09T10:01:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.1.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"4.2.0"}],"SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U24","Model":"HPE ProLiant XL2x260w Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U73","Model":"HPE ProLiant Compute XD680"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"65b3210176a04631ab54616a634c61fc"}]},{"ProductId":"58dd146b67a34b2492cfd64a1feceec4","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 driver."},{"Lang":"ja","Value":"このRPMには、HPEによるテストと承認済みのLinuxベースMellanox RoCE ConnectX-4、ConnectX-5、ConnectX-6、およびConnectX-7ドライバーが含まれます。"},{"Lang":"cn","Value":"This RPM contains HPE Tested and Approved Linux based Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"},{"Lang":"cn","Value":"<p><strong>This driver package supports the following adapters:</strong></p><ul><li><strong>ConnectX4</strong>:<ul><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21 / 825111-H21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21 / 825110-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX4 Lx</strong>:<ul><li>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</li><li>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)&nbsp;</li><li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</li><li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)&nbsp;</li><li>HPE 10/25GbE 2p SFP28 MCX4621 OCP3 Adapter (P11341-B21)&nbsp;<br />&nbsp;</li></ul></li><li><strong>ConnectX5</strong>:<ul><li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</li><li>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter (P31246-B21 / P31246-H21)</li><li>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (874253-B21)</li><li>Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10112-B21)</li><li>Mellanox MCX512F-ACHT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P13188-B21)</li><li>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</li><li>HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (872726-B21 / 872726-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6</strong>:<ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21 / P06154-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21/ P06250-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21 / P06251-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter (P23665-B21 / P23665-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter (P23664-B21 / P23664-H21)</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter (P23666-B21 / P23666-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21 / P31348-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter (P31323-B21 / P31323-H21)</li><li>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter (P31324-B21 / P31324-H21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Dx</strong>:<ul><li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</li><li>Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE (P25960-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX6 Lx</strong>:<ul><li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P42044-B21)</li><li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P42041-B21)<br />&nbsp;</li></ul></li><li><strong>ConnectX7</strong>:<ul><li>HPE InfiniBand NDR200/Ethernet 200GbE 2-port QSFP112 PCIe5 x16 MCX755106AC-HEAT Adapter (P65333-B21)</li></ul></li></ul>"}],"Files":[{"Bytes":"2093039","DateModified":"2025-05-19T19:42:36","FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.3.56.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.3.56.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.56.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.56.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.25.56.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.56.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"MD5Sum":"392c1b94c914164e08b7d9448508b852","Name":"mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm","Release":"2025-05-19T17:44:04","Revision":"","SHA1Sum":"0553c2dac5a4df14e02576c94ec5bd879c587902","SHA256Sum":"315d56f6a61d03496babb630da386e18446ffe5acc2f74fea216e9d7a6f95fac","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"25.01-0.6.0.1"},{"Bytes":"2478480","DateModified":"2025-05-19T19:46:56","FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/compat","./lib/modules/6.4.0-150600.21-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/block","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150600.21-default/updates/net","./lib/modules/6.4.0-150600.21-default/updates/net/9p","./lib/modules/6.4.0-150600.21-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150600.21-default/updates/net/rds","./lib/modules/6.4.0-150600.21-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"MD5Sum":"69d6ec78d4273a081ac3be80b2a6f1dd","Name":"mlnx-ofa_kernel-kmp-default-25.01_k6.4.0_150600.21-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm","Release":"2025-05-19T17:44:04","Revision":"","SHA1Sum":"ce937bc5841174d0f6a58ef327afa0989c8a394b","SHA256Sum":"fed3af0e3227c80c2e53337b4d92b2015cd9b86f927225a07edfb22c2091fb46","Size":"2MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"25.01-0.6.0.1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.01_k6.4.0_150600.21-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"ja","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.01_k6.4.0_150600.21-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"},{"Lang":"cn","Value":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br /><br /><strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-25.01&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<strong>&#39;pciutils&#39; is a prerequisite for installing the EN+RoCE driver.</strong>&nbsp;On SLES15 systems with a minimal OS installation, &#39;pciutils&#39; is not installed by default please ensure it is installed before proceeding with the EN+RoCE driver installation.<br /><br />To install or upgrade the driver:<br />If using 6.4.0-150600.21-default kernel or any future errata:<br /><br /><strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-25.01-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-25.01_k6.4.0_150600.21-OFED.25.01.0.6.0.1.sles15sp6.x86_64.rpm</strong><br /><br />Setup is now complete. Reboot your computer for the driver to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"ja","Value":"Hewlett-Packard Development Company, L.P."},{"Lang":"cn","Value":"Hewlett-Packard Development Company, L.P."}],"Name":[{"Lang":"en","Value":"HPE Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 Driver for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"ja","Value":"HPE Mellanox RoCE ConnectX-4、ConnectX-5、ConnectX-6およびConnectX-7ドライバーfor SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"},{"Lang":"cn","Value":"HPE Mellanox RoCE ConnectX-4, ConnectX-5, ConnectX-6 and ConnectX-7 Driver for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1021","SubDev":"0237","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30237","Type":"pci","Ven":"15B3"},{"Dev":"101f","SubDev":"0012","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30012","Type":"pci","Ven":"15b3"},{"Dev":"101f","SubDev":"0007","SubVen":"15b3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101f15b30007","Type":"pci","Ven":"15b3"},{"Dev":"1021","SubDev":"0053","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-102115b30053","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"02C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1017159002c8","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"032D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-10171590032d","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c9","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0116","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30116","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0052","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30052","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0346","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900346","Type":"pci","Ven":"15B3"},{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0042","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30042","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"02C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c7","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"},{"Dev":"1013","SubDev":"00C7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c7","Type":"pci","Ven":"15b3"},{"Dev":"1013","SubDev":"00C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1013159000c8","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0256","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900256","Type":"pci","Ven":"15b3"},{"Dev":"1017","SubDev":"0282","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900282","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0068","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30068","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0347","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900347","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0345","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900345","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"0348","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15900348","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0069","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30069","Type":"pci","Ven":"15B3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"0074","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b15b30074","Type":"pci","Ven":"15B3"},{"Dev":"101D","SubDev":"0040","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101d15b30040","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-24T12:31:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 24.10-0.7.0.1</strong><strong>:</strong></p><ul><li>[Beta] Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Added kernel support for monitoring RDMA events from userspace. Using the netlink or the RDMA tool, users will be able to monitor the InfiniBand device events and changes such as device register, device unregister and netdev attachment/detachment.</li><li>Added the &ldquo;irqs&rdquo; directory inside the SF sysfs directory to provide the users information about the mapping of SFs and their IRQs.</li><li>Added support for setting a maximum number of completion EQs for SFs.</li><li>Added support for up to 23 bits for uar_page_index in create_cq flow. This allows the user to perform create_cq with a uar_page_index larger than 2^16 as supported by the hardware/firmware.</li><li>[Beta] Added support for specifying bandwidth proportions between traffic classes (TC) in the devlink-rate API. This new option allows users to allocate bandwidth across multiple traffic classes in a single command. This feature provides a more granular control over traffic management, especially for scenarios requiring Enhanced Transmission Selection. Users can now define a specific bandwidth share for each traffic class, such as allocating 20% for TC0 (TCP/UDP) and 80% for TC5 (RoCE).</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 24.10-0.7.0.1:</strong></p><ul><li>The udev rule included an invalid line in its syntax that triggered the error message: &quot;/usr/lib/udev/rules.d/90-ib.rules:4 Only network interfaces can be renamed&quot;.</li><li>&quot;rdma-core&quot; build failure due to the following symbol issues in rdma-core: 1) mad_register_port_client() symbol did not need to be exported 2) The XDR speed decoding functions were not properly exported.</li><li>When trying to configure the initiator/responder depth to 12, the driver actually configured the depth to 8 (power of 2 rounded down), and the user received an RDMA NAK when RDMA read requests were posted.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>バージョン24.10-0.7.0.1には、次の新機能と変更が含まれています</strong><strong>。</strong></p><ul><li>[ベータ] LAGにグループ化された複数のE-SwitchにわたるQoSスケジューリングのサポートが追加されました。ある物理機能のVPortメンバーを、別の物理機能からのレートグループに追加することができ、グループのレート制限はそれらのVPortメンバーにも適用されます。</li><li>ユーザースペースからRDMAイベントを監視するためのカーネルサポートが追加されました。netlinkまたはRDMAツールを使用すると、ユーザーはデバイスの登録、デバイスの登録解除、netdevの接続/切断などのInfiniBandデバイスのイベントと変更を監視できます。</li><li>SFとそのIRQのマッピングに関する情報をユーザーに提供するために、SF sysfsディレクトリ内に\"irqs\"ディレクトリを追加しました。</li><li>SFの完了EQの最大数を設定するためのサポートが追加されました。</li><li>create_cqフローのuar_page_indexに対する最大23ビットのサポートが追加されました。これにより、ユーザーは、ハードウェア/ファームウェアでサポートされている2^16より大きいuar_page_indexを使用してcreate_cqを実行できるようになります。</li><li>[ベータ] devlink-rate APIのトラフィッククラス (TC) 間の帯域幅比率を指定するためのサポートが追加されました。この新しいオプションにより、ユーザーは単一のコマンドで複数のトラフィッククラスにわたって帯域幅を割り当てることができます。この機能により、特に拡張伝送選択を必要とするシナリオにおいて、トラフィック管理をより細かく制御できるようになります。ユーザーは、TC0 (TCP/UDP) に20%、TC5 (RoCE) に80%を割り当てるなど、トラフィッククラスごとに特定の帯域幅のシェアを定義できるようになりました。</li></ul>","Fixes":"<p><strong>以下の問題点がバージョン24.10-0.7.0.1で修正されました。</strong></p><ul><li>udevルールの構文に、次のエラーメッセージをトリガーする無効な行が含まれていました。\"/usr/lib/udev/rules.d/90-ib.rules:4 Only network interfaces can be renamed\"。</li><li>rdma-coreの次のシンボルの問題による\"rdma-core\"のビルドの失敗：1) mad_register_port_client()シンボルをエクスポートする必要がなかった 2) XDR速度デコード関数が適切にエクスポートされなかった。</li><li>イニシエーター/レスポンダーの深度を12に設定しようとすると、ドライバーは実際には深度を8 (2の累乗を切り捨て) に設定し、RDMA読み取り要求が行われたときにユーザーはRDMA NAKを受信した。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 24.10-0.7.0.1</strong><strong>:</strong></p><ul><li>[Beta] Added support for QoS scheduling across multiple E-Switches grouped in a LAG. VPort members of a Physical Function can be added to a rate group from another Physical Function and rate limits of the group will apply to those VPort members as well.</li><li>Added kernel support for monitoring RDMA events from userspace. Using the netlink or the RDMA tool, users will be able to monitor the InfiniBand device events and changes such as device register, device unregister and netdev attachment/detachment.</li><li>Added the &ldquo;irqs&rdquo; directory inside the SF sysfs directory to provide the users information about the mapping of SFs and their IRQs.</li><li>Added support for setting a maximum number of completion EQs for SFs.</li><li>Added support for up to 23 bits for uar_page_index in create_cq flow. This allows the user to perform create_cq with a uar_page_index larger than 2^16 as supported by the hardware/firmware.</li><li>[Beta] Added support for specifying bandwidth proportions between traffic classes (TC) in the devlink-rate API. This new option allows users to allocate bandwidth across multiple traffic classes in a single command. This feature provides a more granular control over traffic management, especially for scenarios requiring Enhanced Transmission Selection. Users can now define a specific bandwidth share for each traffic class, such as allocating 20% for TC0 (TCP/UDP) and 80% for TC5 (RoCE).</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version 24.10-0.7.0.1:</strong></p><ul><li>The udev rule included an invalid line in its syntax that triggered the error message: &quot;/usr/lib/udev/rules.d/90-ib.rules:4 Only network interfaces can be renamed&quot;.</li><li>&quot;rdma-core&quot; build failure due to the following symbol issues in rdma-core: 1) mad_register_port_client() symbol did not need to be exported 2) The XDR speed decoding functions were not properly exported.</li><li>When trying to configure the initiator/responder depth to 12, the driver actually configured the depth to 8 (power of 2 rounded down), and the user received an RDMA NAK when RDMA read requests were posted.</li></ul>","Lang":"cn"}],"Version":"24.10-0.7.0.1"},{"ReleaseNotes":[{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>The following new features and changes have been included in version 25.01-0.6.0.1</strong></p><ul><li>[ConnectX-7] Multi-host LAG: When using a multi-host deployment, each host is assigned unique ports and PFs and manages its own LAG.</li><li>Hardware GRO: Hardware Generic Receive Offload (GRO) reduces CPU overhead and improves throughput by offloading the task of reassembling incoming network packets from the CPU.</li><li>Precision Time Measurement (PTM): Precision Time Measurement (PTM) enhances clock synchronization accuracy between the NIC&#39;s hardware clock and the system&#39;s host clock. It addresses inaccuracies caused by asymmetric PCIe request and response times, which can affect PTP.</li><li>Transport RDMA Steering Domain: Transport RDMA steering domain in the kernel allows users to create steering tables and rules using the new domain types FS_FT_RDMA_TRANSPORT_RX and FS_FT_RDMA_TRANSPORT_TX, with support for both DevX commands and the added functionality in mlx5dv_create_flow_matcher().</li><li>DevX QPs Parallel Cleanup: Reduces cleanup (kill) time of user-space applications that use DevX QPs, without requiring any changes on the user&#39;s end. When using a kernel that includes this patch, DevX QP destruction upon cleanup will be sent to the firmware in parallel, rather than serially as before, resulting in faster cleanup times. The more DevX QPs the application has, the more noticeable the improvement will be.</li><li>Flow Control for Solicited MADs: Implements flow control for solicited MADs in the MAD layer to prevent loss due to insufficient resources at the receiver. Both the client and server function as receivers: the server handles incoming requests, while the client receives the responses.</li><li>Increased the default TX queue length in IPoIB to enhance qdisc queueing and reduce CPU spikes.</li><li>The &quot;--defltprio&quot; flag has been deprecated and removed from the mlnx_qos tool.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in version &nbsp;25.01-0.6.0.1:</strong></p><ul><li>Incorrect SA switching when multiple active TX SAs are created on a SC, caused by failing to respect the SA configured by &quot;encoding_sa&quot;.</li><li>Incorrect&nbsp;receive queue cache size calculation.</li></ul>","Lang":"cn"}],"Version":"25.01-0.6.0.1"}],"SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U17","Model":"HPE ProLiant DL580 Gen9 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U21","Model":"HPE ProLiant XL450 Gen9 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230 (U66)"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"5a6d6c86169c491eb37ef2f9cda46a1b"}]},{"ProductId":"b5747db463a34c8c8ef853b408ae6b5c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージは、Microsoft Windows Server 2022で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1076176","DateModified":"2025-03-28T07:35:14","FileList":["cp065268.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"MD5Sum":"7543f75b20c6fe1674037ae91aea230f","Name":"cp065268.exe","Release":"2025-03-28T07:20:42","Revision":"C","SHA1Sum":"d61d553f7d1009035016abc95bdfa66a56d60790","SHA256Sum":"fe097568f5c78b4046150d60df593914eb485c91536ae327889cd2804a0acb61","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.5.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel E1R Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel E1Rドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel E1R Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T07:31:50","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"14.0.5.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes to update the INF file to enable the DmaRemappingCompatible feature with a value of 2.</p>","Lang":"cn"}],"Version":"14.0.5.0"}],"SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"c85b0f898c9b41b09538bba4a6aee7ce"}]},{"ProductId":"2fa1597649f243c092f040a8ecf90232","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQ"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPK2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"22502483","DateModified":"2025-03-06T09:04:48","FileList":["/CP065974_BUILD_3.data","/CP065974.vmexe64","/CP065974.vmfile","/CP065974_VMw.zip","/CP065974.xml","/payload.json","/CP065974_VMw.zip/index.xml","/CP065974_VMw.zip/vendor-index.xml","/CP065974_VMw.zip/metadata.zip","/CP065974_VMw.zip/vib20/CP065974/HPE_bootbank_CP065974_HPK3.3-1OEM.800.1.0.20613240.vib","/CP065974_VMw.zip/metadata.zip/vendor-index.xml","/CP065974_VMw.zip/metadata.zip/vmware.xml","/CP065974_VMw.zip/metadata.zip/vibs/CP065974-1573125477705993165.xml","/CP065974_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065974_HPK3.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"1845fed43c4b80ca4e10ff1dde8be0a0","Name":"CP065974.zip","Release":"2025-03-06T09:03:56","Revision":"H","SHA1Sum":"a052c136f09aa8ae33c26b4b1b9819c576d987f0","SHA256Sum":"aa9761003f6ef9447ee99fd89f13910694b98591c80e00d30be3c97180cca1f4","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK3","VibList":[{"Name":"CP065974","Version":"HPK3.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP036934.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、 VK000960KWWFL、VK001920KWWFN、 VK003840KWWFPおよびVK007860KWWFQドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VK007680KWWFQ","TargetGUID":"562340a5-304b-3730-3638-304b57574651","Type":"nvme"},{"Id":"MK006400KWWFK","TargetGUID":"4d2340a5-304b-3630-3430-304b5757464b","Type":"nvme"},{"Id":"VK003840KWWFP","TargetGUID":"562340a5-304b-3330-3834-304b57574650","Type":"nvme"},{"Id":"MK003200KWWFH","TargetGUID":"4d2340a5-304b-3330-3230-304b57574648","Type":"nvme"},{"Id":"VK001920KWWFN","TargetGUID":"562340a5-304b-3130-3932-304b5757464e","Type":"nvme"},{"Id":"MK001600KWWFF","TargetGUID":"4d2340a5-304b-3130-3630-304b57574646","Type":"nvme"},{"Id":"VK000960KWWFL","TargetGUID":"562340a5-304b-3030-3936-304b5757464c","Type":"nvme"},{"Id":"MK00800KWWFE","TargetGUID":"002340a5-4b4d-3030-3830-304b57574645","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T12:49:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK3"}],"SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"adc681f32ce94142a2a2f1eeaadc5385"}]},{"ProductId":"c20869f6e72044ccb4d2b142b029a1ef","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p><p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp;&nbsp; None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"5500739","DateModified":"2025-05-15T10:30:04","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/CP066596.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066596.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066596.scexe"],"MD5Sum":"252bd5970e9d6aee51dee5a457223a11","Name":"firmware-hdd-d39e7a7e75-HPG1-14.1.x86_64.rpm","Release":"2025-05-15T15:18:04","Revision":"N","SHA1Sum":"fa3798818aaeb1f932718a8aaa9d48e29cafb039","SHA256Sum":"efbd6540b98a92fe193d71e4a0d42f32aa5a13cf7accdf22ab2e1827b182fcc8","Size":"5MB","TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"CP040351.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li><em>rpm -ivh <rpm_filename>コマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子なしのrpmファイル名）を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容を<em>rpm2cpio <rpm_filename>.rpm | cpio -idコマンドを用いて抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd-<xxxxxxxxxx>-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報：</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul style=\"list-style-type:square\"><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&language=en_US\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-27T18:05:27","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"87bec7f582d5485e980870c6d97afc61"}]},{"ProductId":"3b175f364fc14c6da598ff868e4cfb48","Versions":[{"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM2_1.20_F.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"1.20"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains PLDM firmware for UBM2 storage backplanes."},{"Lang":"ja","Value":"このファームウェアパッケージには、UBM2ストレージバックプレーンのPLDMファームウェアが含まれています。"},{"Lang":"cn","Value":"This firmware package contains PLDM firmware for UBM2 storage backplanes."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"64279","DateModified":"2024-09-13T05:13:18","FileList":["HPE_UBM2_1.20_F.HPb","HPE_UBM2_1.20_F.xml","payload.json"],"MD5Sum":"19ac58fab628d72a35cc265bec6cee58","Name":"HPE_UBM2_1.20_F.fwpkg","Release":"2024-09-13T05:09:10","Revision":"F","SHA1Sum":"db8184aeb99d025d5c3746b531b3c07c11dfc53a","SHA256Sum":"dd4a5f892598d44d89c68f4b3332cfbda9cdba8ce01771355529ace5ad9e4c5e","Size":"62KB","TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901502000000"],"TypeOfChange":"1","Version":"1.20"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"},{"Lang":"ja","Value":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p><ol><li>iLOrestツールを使用したフラッシュ </li><li>Smart Update Manager（SUM）を使用したフラッシュ</li><li>iLO GUIからのフラッシュ</li></ol><p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>    ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>    リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO_IP_Address> -u <iLO_username> -p <iLO_password></em></strong></p><p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p></li><li><p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p></li></ul><p>     通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>3. iLO GUIからのフラッシュ</p><ul><li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li><li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li><li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li><li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリーが記録されます。 </li></ul>"},{"Lang":"cn","Value":"<p>Flash the PLDM firmware using any below methods</p><ol><li>Flash using iLOrest tool&nbsp;</li><li>Flash using&nbsp;Smart Update Manager (SUM).</li><li>Flash from iLO GUI</li></ol><p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>&nbsp; &nbsp; localhost OS example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>&nbsp; &nbsp; remote example:<br /><strong><em>&nbsp; &nbsp; ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO_IP_Address&gt; -u &lt;iLO_username&gt; -p &lt;iLO_password&gt;</em></strong></p><p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>&nbsp; &nbsp; Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li><p>Place the Service Pack for ProLiant on a USB key using the&nbsp;USB Key Creator Utility.</p></li><li><p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p></li></ul><p>&nbsp; &nbsp; &nbsp;Update the firmware and software&nbsp;in the usual manner.</p><p>3.&nbsp;Flash from iLO GUI</p><ul><li>Browse iLO IP using any browser and login using the credential&nbsp;</li><li>Make sure the PLDM supported adapter is present in the server</li><li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li><li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers"},{"Lang":"ja","Value":"ファームウェアパッケージ - UBM2バックプレーンPIC PLDMファームウェアfor Gen10/Gen10 Plus/Gen11サーバー"},{"Lang":"cn","Value":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedDevices":[{"Id":"9675b54e-1c96-44c3-a7a1-901502000000","TargetGUID":"","Type":"nvmeubmpicnew"}],"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-13T04:32:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support both Gen10P and Gen11 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Gen10PおよびGen11サーバーの両方をサポートします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support both Gen10P and Gen11 servers</p>","Fixes":"","Lang":"cn"}],"Version":"1.20"},{"ReleaseNotes":[{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new Gen12 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"1.20"}],"SWKeys":[{"Name":"UBM2PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U68","Model":"HPE ProLiant DL380 Gen12 Server"},{"Family":"U68","Model":"HPE ProLiant DL360 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"03cdf815345f4efd94751eaefd47e77f"}]},{"ProductId":"3d1400a6e0204fb498134f7e6e3f374a","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; None</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp; &nbsp; None</p>"}],"Files":[{"Bytes":"3642064","DateModified":"2025-01-11T03:14:12","FileList":["cp065066.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATSATAG1.REL"],"MD5Sum":"7c4e2b4dd2c5bae0709eeb6081e80762","Name":"cp065066.exe","Release":"2025-01-11T03:10:05","Revision":"J","SHA1Sum":"4577a70f266bc365c05a6e830a487c962bc0f55a","SHA256Sum":"0dcdc61d8770bdf0a2685e32f886b8b0027e0e7ff0e40cc7ecb035b65ea6039d","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000GWFWB","TargetGUID":"4d2340a5-3042-3430-3030-304757465742","Type":"sata"},{"Id":"MB002000GWFWA","TargetGUID":"4d2340a5-3042-3230-3030-304757465741","Type":"sata"},{"Id":"MB001000GWJAN","TargetGUID":"4d2340a5-3042-3130-3030-3047574a414e","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:17:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG1"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG1"}],"SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6720cc3709904c8c9c7bb235b4af2a15"}]},{"ProductId":"e0822b357e024225a58d203426c0d686","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000JWFVKおよびMB006000JWFVL"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2..</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2..</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp; &nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"3281688","DateModified":"2025-01-11T02:57:14","FileList":["cp065049.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATdsHPD4.REL"],"MD5Sum":"494763b6fc6340e815fbed3514575fc1","Name":"cp065049.exe","Release":"2025-01-11T02:52:48","Revision":"F","SHA1Sum":"5245ad8cd427cb5060cf7617e395be9a9944f09d","SHA256Sum":"67bd1c9cbcfc22e088603f051962ec8009f712672a38d94e6f72f9bf24500fb4","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JWFVK","TargetGUID":"4d2340a5-3042-3430-3030-304a5746564b","Type":"sas"},{"Id":"MB006000JWFVL","TargetGUID":"4d2340a5-3042-3630-3030-304a5746564c","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T11:05:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.<br />&nbsp;</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Microsoft Windows Server 2025のサポートを追加しました。<br /> </li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Microsoft Windows Server 2025.<br />&nbsp;</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB004000JWFVK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWFVL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"46fc7ca8a03140e2a6e022426dceea63"}]},{"ProductId":"f201f1f45a1041f9819da1901ffe255f","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v3.72 (05/16/2025)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34055647","DateModified":"2025-05-21T07:36:28","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/A42_3.72_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/CP067149.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-3.72_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067149.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067149.scexe"],"MD5Sum":"98875d70e56040f087464ecc8e9aa148","Name":"firmware-system-a42-3.72_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-26T00:00:00","Revision":"","SHA1Sum":"d81299e4986cffe510fba5f53d7bf0f78c4b86c1","SHA256Sum":"9a146e4aed4e57bd229150170ef77d3a03cb35954af89683a7d65da0ae763757","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:22:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>8TBのシステムメモリとE810 NICカードがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory and E810 NIC card installed.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"f58c18a103e04fe48586983d360f9be0"}]},{"ProductId":"9a174e7fb7c74693abe3d57081da0d45","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 5."},{"Lang":"ja","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 5."},{"Lang":"cn","Value":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 9 Update 5."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"41139","DateModified":"2025-04-24T09:44:21","FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/0a47d3531eb4dcff7adff0f1a24a6f9b0eb3fe","./usr/lib64/libbnxt_re-233.0.152.2.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"MD5Sum":"09adf830512e42599a33a7ce857fae3d","Name":"libbnxt_re-233.0.152.2-rhel9u5.x86_64.rpm","Release":"2025-04-24T09:41:39","Revision":"","SHA1Sum":"0749f556ae778b37d91e65db86d99f33497fd07c","SHA256Sum":"d646173f1d1719211fb64908f04b0c85b8cce7b70c82509e6b797c52ba5253d4","Size":"40KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"0","Version":"233.0.152.2"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"ja","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"},{"Lang":"cn","Value":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 5."},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 5."},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 5."}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159016d7","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16C500000000","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020c","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c515900211","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c51590020e","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d8","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-14E4-16BD00000000","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd15900211","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16DC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16dc159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C5","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c5159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16BD","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16bd159002c5","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E124","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e124","Type":"pci","Ven":"14E4"},{"Dev":"1760","SubDev":"E324","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e324","Type":"pci","Ven":"14E4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1760","SubDev":"E116","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-176014e4e116","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"16C1","SubDev":"16D7","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16c1159016d7","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-03T05:51:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"233.0.152.2"}],"SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Optional"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"921f006f3fba44469e1877b96f57acd7"}]},{"ProductId":"5588a72e9c0d4878a499b54f0c18241c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE ESXi Agentless Management Smart Component for ESXi includes the latest HPE Agentless Management Service (AMS)."},{"Lang":"ja","Value":"HPE ESXi Agentless Management Smartコンポーネントfor ESXiには、最新のHPE Agentless Management Service（AMS）が含まれています。"},{"Lang":"cn","Value":"The HPE ESXi Agentless Management Smart Component for ESXi includes the latest HPE Agentless Management Service (AMS)."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"7182953","DateModified":"2025-05-29T05:23:18","FileList":["/cp066689.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip","/amsdComponent_802.11.11.5.4-1_24720090.zip/index.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip/vendor-index.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip/metadata.zip","/amsdComponent_802.11.11.5.4-1_24720090.zip/vib20/amsd/HPE_bootbank_amsd_802.11.11.5.4-1OEM.802.0.0.22380479.vib","/amsdComponent_802.11.11.5.4-1_24720090.zip/metadata.zip/vendor-index.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip/metadata.zip/vmware.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip/metadata.zip/vibs/amsd-6082656878279900857.xml","/amsdComponent_802.11.11.5.4-1_24720090.zip/metadata.zip/bulletins/amsdComponent_802.11.11.5.4-1.xml"],"MD5Sum":"c7308e897d41353ba2e2c22e290460d9","Name":"cp066689.zip","Release":"2025-05-29T05:23:04","Revision":"","SHA1Sum":"fb02abb00ccbfa539b840ed93bf9d796b3506bee","SHA256Sum":"b8006dbd46db805bc98c29441035df99636c80b1e685d8a7edcde59b45e30087","Size":"6MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"TypeOfChange":"1","Version":"2025.05.01","VibList":[{"Name":"amsd","Version":"802.11.11.5.4-1OEM.802.0.0.22380479"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=false","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":200,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the smart component zip file to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip the&nbsp;HPE smart&nbsp;component zip file to extract the driver offline bundle&nbsp;zip file.</li><li>Copy the driver offline bundle zip file extracted in the previous step&nbsp;to the VMware host server.</li><li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li></ul>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p><ul><li>適切なService Pack for ProLiantをダウンロードします</li><li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li><li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li><li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li><li>Smart Update Managerの指示に従ってアップデートを行います。</li><li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li></ul><p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p><ul><li>ドライバーオフラインバンドルのzipファイルを抽出するために、HPE Smartコンポーネントのzipファイルを解凍します。</li><li>前の手順で抽出したドライバーオフラインバンドルのzipファイルをVMwareホストサーバーにコピーします。</li><li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li><li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p><ul><li>Download the appropriate Service Pack for ProLiant</li><li>Add the smart component zip file to the Service Pack for ProLiant</li><li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target/node</li><li>Enter the IP or DNS address of the ESXi host to be updated</li><li>Enter the ESXi host credentials (root or administrator username and password)</li><li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update.</li><li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li></ul><p><strong>To update the driver using VMware tools:</strong></p><ul><li>Unzip the&nbsp;HPE smart&nbsp;component zip file to extract the driver offline bundle&nbsp;zip file.</li><li>Copy the driver offline bundle zip file extracted in the previous step&nbsp;to the VMware host server.</li><li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li><li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers"},{"Lang":"ja","Value":"HPE Agentless ManagementバンドルSmartコンポーネントon ESXi for Gen10およびGen10 Plusサーバー"},{"Lang":"cn","Value":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"700"},"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-05-07T07:25:17","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2025.03.01"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the&nbsp;<a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2025.05.01"}],"SWKeys":[{"Name":"amsdComponent:802.11.11.5.4-1","SWKeyExpectedPath":"software.component:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE MicroServer Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"afdcd5951ff34634b4d048e306657fc7"}]},{"ProductId":"4cf79b782386458fa01aea2ca94f4962","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPDA"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVNGSDA.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPDA"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPDA<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD9<br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for RHEL 10.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp; &nbsp; &nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"5580932","DateModified":"2025-05-14T07:46:07","FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/CP066503.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/SAVNGSDA.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPDA-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066503.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066503.scexe"],"MD5Sum":"57b651a795dd12fce6c5194bcba03b01","Name":"firmware-hdd-b04257b77b-HPDA-6.1.x86_64.rpm","Release":"2025-05-14T12:34:40","Revision":"F","SHA1Sum":"b9040c2f65890090c495fcc75d9565b16b87fb86","SHA256Sum":"737e531b647824fae395a5a1c7163edd45372b8880d15dc9419ed54a14308a50","Size":"5MB","TargetGUIDs":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"TypeOfChange":"1","Version":"HPDA"}],"Installation":{"Command":"CP040271.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul style=\"list-style-type:square\"><li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li><li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p><ul style=\"list-style-type:square\"><li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p><ul style=\"list-style-type:square\"><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /packages.</li><li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p><ul style=\"list-style-type:square\"><li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li><li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul style=\"list-style-type:square\"><li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li><li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p><ul style=\"list-style-type:square\"><li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li><li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p><p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン:</strong></p><ul style=\"list-style-type:square\"><li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li><li>新たに作成したService Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p><ul style=\"list-style-type:square\"><li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li><li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li><li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"4000"},"SupportedDevices":[{"Id":"MM1000JEFRB","TargetGUID":"002340a5-4d00-314d-3030-304a45465242","Type":"sas"},{"Id":"MM2000JEFRC","TargetGUID":"002340a5-4d00-324d-3030-304a45465243","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T19:11:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>SDR方式によるフラッシュの問題を修正しました</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixed flashing issue through SDR method</li></ul>","Lang":"cn"}],"Version":"HPDA"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPDA"}],"SWKeys":[{"Name":"MM1000JEFRB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MM2000JEFRC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"60cdffea2a1e42c5b5a9a902f468d1a2"}]},{"ProductId":"4aaa1b96312a4790820f2c40ac3eb0e7","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SAVGNSD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPD4<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"19175696","DateModified":"2025-03-06T07:03:39","FileList":["/CP066005_BUILD_4.data","/CP066005.vmexe64","/CP066005.vmfile","/CP066005_VMw.zip","/CP066005.xml","/payload.json","/CP066005_VMw.zip/index.xml","/CP066005_VMw.zip/vendor-index.xml","/CP066005_VMw.zip/metadata.zip","/CP066005_VMw.zip/vib20/CP066005/HPE_bootbank_CP066005_HPD5.4-8.0.0.20613240.vib","/CP066005_VMw.zip/metadata.zip/vendor-index.xml","/CP066005_VMw.zip/metadata.zip/vmware.xml","/CP066005_VMw.zip/metadata.zip/vibs/CP066005--9038234977815441205.xml","/CP066005_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066005_HPD5.4-8.0.0.20613240.xml"],"MD5Sum":"16a1cc8bc6f17fb66efb0f60d1a1ab80","Name":"CP066005.zip","Release":"2025-03-06T07:02:50","Revision":"E","SHA1Sum":"49963f960ef9c70f3d4d803afa08f0224925c9f1","SHA256Sum":"0785d4a222d482b8e38b00962be0011a6e0eb256d7fa1e04e99aead96b3164e4","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-4d00-314d-3030-304a464a5448"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP066005","Version":"HPD5.4-8.0.0.20613240"}]}],"Installation":{"Command":"CP040517.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000JFJTHドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MM1000JFJTH","TargetGUID":"002340a5-4d00-314d-3030-304a464a5448","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:03:58","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD5"}],"SWKeys":[{"Name":"MM1000JFJTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"accf85e27715420fa50c2afc082f49f0"}]},{"ProductId":"1f3d9896fbab4dc5aed295b2183323a0","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.42 (06/13/2025)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34230616","DateModified":"2025-06-16T02:24:20","FileList":["cp067568.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U46_2.42_06_13_2025.signed.flash"],"MD5Sum":"371deeb9a6f6c97ffcf4400709ea881f","Name":"cp067568.exe","Release":"2025-06-16T02:21:52","Revision":"","SHA1Sum":"517b62933f970bbf6a8ab56b284e0ccd69a9f29a","SHA256Sum":"e7f1f802df6e7c3be3ac09bcb0ed06126af46622a762dea14af786f3b608b401","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上にあるSmart Update Managerを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:21:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"857bfcbe05ed4b8b89774abbd85ed3ba"}]},{"ProductId":"30c69f83193c4f679a84938a219df0d6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"},{"Lang":"cn","Value":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1415544","DateModified":"2025-04-01T02:53:13","FileList":["cp065299.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"MD5Sum":"5b5074bda64e80bb68fa4e24d8a991e0","Name":"cp065299.exe","Release":"2025-04-01T02:39:19","Revision":"B","SHA1Sum":"5f451828f8763c9c24a3a2acfcff84b9f0a7a891","SHA256Sum":"eebe1434e337d299a4e868d07587e0c9c8f66717783c113f486723f824299eb5","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.16.100.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel iavf Driver for Windows Server 2022"},{"Lang":"ja","Value":"HPE Intel iavfドライバー for Windows Server 2022"},{"Lang":"cn","Value":"HPE Intel iavf Driver for Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"37CD","SubDev":"0000","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-37CD15900000","Type":"pci","Ven":"8086"},{"Dev":"37CD","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-37cd80860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0001","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-157180860001","Type":"pci","Ven":"8086"},{"Dev":"1571","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-157100000000","Type":"pci","Ven":"8086"},{"Dev":"154c","SubDev":"0000","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-154c103c0000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T08:49:22","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"1.14.203.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where Large Send Offload (LSO) is not working.</p>","Lang":"cn"}],"Version":"1.16.100.0"}],"SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"e5223c34437248748019570a92b16b6a"}]},{"ProductId":"ec5ba4f75ae340e39f8e129f646a9647","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."},{"Lang":"ja","Value":"このパッケージには、Linuxオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td><td>14.32.1900</td><td>MT_0000000414</td></tr><tr><td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td><td>14.32.1900</td><td>MT_0000000238</td></tr><tr><td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td><td>16.35.4030</td><td>MT_0000000417</td></tr></tbody></table>"}],"Files":[{"Bytes":"8657552","DateModified":"2024-10-18T06:12:31","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/CP063119.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1900-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1900-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw/fw-ConnectX5-rel-16_35_4030-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.12-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063119.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063119.scexe"],"MD5Sum":"46a3b28e43efbe796910b1686e0c1de5","Name":"firmware-nic-open-mellanox-eth-mft-1.0.12-1.1.x86_64.rpm","Release":"2024-10-18T11:09:46","Revision":"","SHA1Sum":"df6be5f35e98215d5d814e8806f77f22b446819e","SHA256Sum":"f79e8d4b54a8ed58bde94e5db583de9fc51d2ee5200d1c8a1fe5f8e05ab0d544","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"},{"Lang":"ja","Value":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Linux x86_64）"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0117","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715b30117","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0102","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30102","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"0047","SubVen":"15B3","TargetGUID":"a6b1a447-382a-5a4f-15b3-101515b30047","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-03T09:21:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.3502:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.<br />&nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.<br />&nbsp;</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>P21930-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4121A-XCATアダプター)</li><li>P11341-B21(HPE Ethernet 10Gb 2ポートSFP+ MCX4621A-ACAB OCP3アダプター)</li></ul><p> </p><p><strong>次のデバイス用のファームウェアが16.35.3502にアップデートされました。</strong></p><ul><li>P21927-B21（HPE Ethernet 100Gb 2ポートQSFP28 MCX516A-CCHTアダプター）</li></ul><p> </p><p><strong>ファームウェアバージョン14.32.1010には新機能の追加も変更もありません。</strong></p><ul><li>3つの新しいアサートフィルター(ヘルスバッファー、NVlog、FWトレース)が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ(rate_limitに接続し、そのレート制限を共有するレート制限要素)へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。有効にするには、PF_NUM_OF_VF_VALIDをtrueにし、PF_NUM_OF_VFをゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。<br /> </li></ul><p><strong>ファームウェアバージョン16.35.3502には新機能の追加も変更もありません。</strong></p><ul><li>TCP IPv4フローを変更し、ステアリングTIR rx_hash_symmetricフィールドが、SRCフィールドとDST フィールドの両方がゼロに設定されていない場合にのみ有効になるようになりました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアバージョン14.32.1010で修正されました。</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。<br /> </li></ul><p><strong>ファームウェアバージョン16.35.3502には修正が含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.3502:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p>&nbsp;</p><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.<br />&nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.<br />&nbsp;</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"cn"}],"Version":"1.0.11"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li><li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li></ul><p>&nbsp;</p><p><strong>Firmware for the following device&nbsp;has been updated to 16.35.4030:</strong></p><ul><li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong><br />&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.12"}],"SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8c2fa2acc66543d58749447fee9bde89"}]},{"ProductId":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB004000JWWQB and MB002000JWWQA"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQBおよびMB002000JWWQA"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB and&nbsp;MB002000JWWQA Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"4193864","DateModified":"2025-01-11T10:23:13","FileList":["cp065081.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNSD8.rel","setup.dll"],"MD5Sum":"5f2d5763de6bb6e522e0c2a164ace7fc","Name":"cp065081.exe","Release":"2025-01-11T10:18:39","Revision":"D","SHA1Sum":"c334e72628d24eb7224f037569c02b2a18594fec","SHA256Sum":"65a743f2d4a8c2cfb86fd888b666104d4aff53654119e685824650879ea78027","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB and MB002000JWWQA Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000JWWQBおよびMB002000JWWQAドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB004000JWWQB","TargetGUID":"4d2340a5-3042-3430-3030-304a57575142","Type":"sas"},{"Id":"MB002000JWWQA","TargetGUID":"4d2340a5-3042-3230-3030-304a57575141","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:23:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e0943263ab7846f38694cac97a9a9271"}]},{"ProductId":"2a95310f5de64c9fad6c33cfacf5d307","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SATA Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SATAストレージ ディスク"},{"Lang":"cn","Value":"固件 - SATA 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"Lang":"ja","Value":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp;HPG2</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;HPG2<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong></p><ul><li>Restrict downgrade to HPG1 or HPG0</li></ul>"}],"Files":[{"Bytes":"8190144","DateModified":"2025-01-11T06:39:14","FileList":["cp065062.xml","cpqsetup.exe","K511HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"5d511208ce9cf5f0e9c60ae97af8c7d2","Name":"cp065062.exe","Release":"2025-01-11T06:35:01","Revision":"C","SHA1Sum":"db5b5b644d52df8168726b51a61c46bd56233a17","SHA256Sum":"cfe48f16aedba137bd20b7a2607ae70b770e5ae8c57bf53f80eaaa70f1ed1bc7","Size":"7MB","TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li><li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"VK000480GZCNE","TargetGUID":"562340a5-304b-3030-3438-30475a434e45","Type":"sata"},{"Id":"VK000960GZCNF","TargetGUID":"562340a5-304b-3030-3936-30475a434e46","Type":"sata"},{"Id":"VK001920GZCNH","TargetGUID":"562340a5-304b-3130-3932-30475a434e48","Type":"sata"},{"Id":"VK003840GZCNK","TargetGUID":"562340a5-304b-3330-3834-30475a434e4b","Type":"sata"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T12:01:28","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPG3"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPG3"}],"SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"cca5817a12074cc8b56484136dbcbcdf"}]},{"ProductId":"29a000381a7c4ec8a72063a155821a0a","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"Lang":"ja","Value":"この製品には、SUSE Linux Enterprise Server 15で動作するIntel ice Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"1101664","DateModified":"2025-04-01T08:24:31","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.39.1.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/ice","./lib/modules/6.4.0-150600.21-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"MD5Sum":"018c37ca6d07da342623db6a462dba6c","Name":"ice-kmp-default-1.16.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","Release":"2025-04-01T08:14:05","Revision":"B","SHA1Sum":"d947c520c5b2218f229d55c08766fa47df8bdb6e","SHA256Sum":"147999f6480c8c986d6222aa219a8fc1bcc965f6e21a5c6b8ff703b292cfd2c5","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"1.16.4-1"},{"Bytes":"931492","DateModified":"2025-04-01T08:20:14","FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.39.1.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.21-150500.53-default","./lib/modules/5.14.21-150500.53-default/updates","./lib/modules/5.14.21-150500.53-default/updates/ice","./lib/modules/5.14.21-150500.53-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"MD5Sum":"4fc0fc6041b38e3f0bfa4d361f1775e9","Name":"ice-kmp-default-1.16.4_k5.14.21_150500.53-1.sles15sp5.x86_64.rpm","Release":"2025-04-01T08:14:05","Revision":"B","SHA1Sum":"1762f41dc995396a4136f172c00f6421033166a1","SHA256Sum":"a2d2032444d04de422fc562e9027f0ba2a3179a39298163cbb9df3a97399f726","Size":"909KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"1.16.4-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Intel ice Drivers for SUSE Linux Enterprise Server 15"},{"Lang":"ja","Value":"Intel iceドライバーfor SUSE Linux Enterprise Server 15"},{"Lang":"cn","Value":"Intel ice Drivers for SUSE Linux Enterprise Server 15"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"1593","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000e","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-23T06:55:33","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品は現在、新しいプラットフォームでサポートされています。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is now supported on a new platform.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.4-1"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes an issue where the ice driver failed to load when the transmit balancing feature was enabled in the NIC HII menu.</p>","Lang":"cn"}],"Version":"1.16.4-1"}],"SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant DL580 Gen12"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"2aa0aed47e3f44398f0ecd43b0332c38"}]},{"ProductId":"348f4fc22c0c4f64b2e050cebccb4347","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064980.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"},{"Lang":"cn","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2918728","DateModified":"2025-02-10T07:57:14","FileList":["cp064980.compsig","cp064980.zip","cp065604.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"4cf60acf44c4f5e3cffb73df7501e9a5","Name":"cp065604.exe","Release":"2025-02-10T07:55:23","Revision":"B","SHA1Sum":"80bd6a3e196afd88325a3bd65e3c9b4f67766350","SHA256Sum":"19ce09deb1c33468960734de511427ca6f01855ae948965ba0e6740d68d5ffce","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":600,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います:</strong><br />1.    サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムに<filename>.exeをダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />2.    ファイル名を右クリックして、プロパティを選択します。<br />3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />        a.    ファームウェアを展開しないでください。<br />        b.    ファームウェアをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p><p><br /><strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />1.    Microsoft Windows CRC/SHAツールを使用して、<filename>.exeのSHA256ハッシュ値を計算します。 <br />2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />•    値が一致しない場合は、ファイルやそのコンテンツを展開しないでください。<br />•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p><p><filename>.exeを実行し、画面の指示に従ってインストールを完了してください。<br />ドライバーのインストールが完了した後、サーバーを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p><p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />1. &nbsp; &nbsp;Download &lt;filename&gt;.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />2. &nbsp; &nbsp;Right-click the filename then select Properties<br />3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p><p><br /><strong>To verify the SHA256 hash value, do the following steps:</strong><br />1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for &lt;filename&gt;.exe.&nbsp;<br />2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p><p>Execute the file &lt;filename&gt;.exe and follow onscreen instructions to finish the installation.<br />After the driver installaton is complete, please restart the server.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services (SPS)ファームウェア for HPE ProLiant MicroServer Gen10 Plus v2"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T07:48:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"e1c6772d6a5241e58f67c55dc47cb1b7"}]},{"ProductId":"376766abc4f1493fa567046abeb8b7d6","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"5519031","DateModified":"2025-05-24T07:32:58","FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"MD5Sum":"fcb88958295867a7141ef00cfc147bd6","Name":"kmod-qlgc-qla2xxx-10.02.14.00_k1-3.rhel10u0.x86_64.rpm","Release":"2025-05-24T07:27:04","Revision":"","SHA1Sum":"9fe35f71b812bd0caff5ce652cc21a710584b206","SHA256Sum":"319b85012dcb14dc42612ad91c9d8f825bec1a35fc2ae26b97fd0915d9cbab34","Size":"5MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.14.00-k1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"ja","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.09.00.a8_k1-1.rhel9u2.x86_64.rpm<br /><br />4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 10 Update 0 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"2281","SubDev":"036A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-22811590036a","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"0369","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-228115900369","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00FA","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000fa","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"00F9","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2261159000f9","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0204","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900204","Type":"pci","Ven":"1077"},{"Dev":"2261","SubDev":"0203","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-226115900203","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d3","Type":"pci","Ven":"1077"},{"Dev":"2281","SubDev":"02D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-2281159002d4","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-20T04:10:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added Support For:</p><p>Red Hat Enterprise Linux 10</p><p>Red Hat Enterprise Linux 9.6</p><p>Updated Driver version&nbsp;10.02.14.00-k1</p>","Fixes":"","Lang":"cn"}],"Version":"10.02.14.00-k1"}],"SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"bcdb5ae199284b4d8820f98aec46003d"}]},{"ProductId":"a25f1000baab4c289a20555c0f1143b1","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHE"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD2<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2.</li></ul><p><strong>Problems Fixed:</strong></p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4363680","DateModified":"2025-01-11T10:41:13","FileList":["cp065082.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSSD4.rel"],"MD5Sum":"a6157ffb8a1b7c18fadc557309fbdf36","Name":"cp065082.exe","Release":"2025-01-11T10:36:42","Revision":"D","SHA1Sum":"b8a1944bcc4d299b8fff7fb301c012e3607dd19c","SHA256Sum":"8fc7ce6d00a844be661d0eb908f221d5407c55a8794299a025abaed6ccc6015a","Size":"4MB","TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64） - MB010000JWZHA、MB012000JWZHB、MB014000JWZHC、およびMB016000JWZHEドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB010000JWZHA","TargetGUID":"4d2340a5-3042-3031-3030-304a575a4841","Type":"sas"},{"Id":"MB012000JWZHB","TargetGUID":"4d2340a5-3042-3231-3030-304a575a4842","Type":"sas"},{"Id":"MB014000JWZHC","TargetGUID":"4d2340a5-3042-3431-3030-304a575a4843","Type":"sas"},{"Id":"MB016000JWZHE","TargetGUID":"4d2340a5-3042-3631-3030-304a575a4845","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-11T07:24:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4cefbaba980a4df7955ca3c9aaf0cb6b"}]},{"ProductId":"eacabd6c758c41759c1c132130d3f614","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"ja","Value":"Firmware - PCIe NVMe Storage Disk"},{"Lang":"cn","Value":"固件 - PCIe NVMe存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p><ul style=\"list-style-type:square\"><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />&nbsp;<br /><strong>Release Version and/or Date:</strong><br />&nbsp; &nbsp; &nbsp; HPK5</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />&nbsp; &nbsp; &nbsp; </strong>HPK3</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p><ul style=\"list-style-type:square\"><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>"}],"Files":[{"Bytes":"22562137","DateModified":"2025-03-06T10:07:31","FileList":["/CP065979_BUILD_11.data","/CP065979.vmexe64","/CP065979.vmfile","/CP065979_VMw.zip","/CP065979.xml","/payload.json","/CP065979_VMw.zip/index.xml","/CP065979_VMw.zip/vendor-index.xml","/CP065979_VMw.zip/metadata.zip","/CP065979_VMw.zip/vib20/CP065979/HPE_bootbank_CP065979_HPK5.11-8.0.0.20613240.vib","/CP065979_VMw.zip/metadata.zip/vendor-index.xml","/CP065979_VMw.zip/metadata.zip/vmware.xml","/CP065979_VMw.zip/metadata.zip/vibs/CP065979--8238576472117587209.xml","/CP065979_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065979_HPK5.11-8.0.0.20613240.xml"],"MD5Sum":"cf549f0dbf08fb4faa38bb497add9796","Name":"CP065979.zip","Release":"2025-03-06T10:06:47","Revision":"E","SHA1Sum":"219dd47c2843f0484bdfe6dac752aaefbb1d8f9d","SHA256Sum":"8007b07a290fbc0f1a2b999cef4e4af9de20cd030577b59dd8e88850fde17bc3","Size":"21MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5","VibList":[{"Name":"CP065979","Version":"HPK5.11-8.0.0.20613240"}]}],"Installation":{"Command":"CP042960.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"},{"Lang":"ja","Value":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul style=\"list-style-type:square\"><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul style=\"list-style-type:square\"><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"Lang":"ja","Value":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"VO000960KXAVL","TargetGUID":"562340a5-304f-3030-3936-304b5841564c","Type":"nvme"},{"Id":"MO000800KXAVN","TargetGUID":"4d2340a5-304f-3030-3830-304b5841564e","Type":"nvme"},{"Id":"MO001600KXAVT","TargetGUID":"4d2340a5-304f-3130-3630-304b58415654","Type":"nvme"},{"Id":"MO003200KXAVU","TargetGUID":"4d2340a5-304f-3330-3230-304b58415655","Type":"nvme"},{"Id":"MO006400KXAVV","TargetGUID":"4d2340a5-304f-3630-3430-304b58415656","Type":"nvme"},{"Id":"VO003840KXAVQ","TargetGUID":"562340a5-304f-3330-3834-304b58415651","Type":"nvme"},{"Id":"VO007680KXAVR","TargetGUID":"562340a5-304f-3730-3638-304b58415652","Type":"nvme"},{"Id":"VO001920KXAVP","TargetGUID":"562340a5-304f-3130-3932-304b58415650","Type":"nvme"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:15:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPK5"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"<ul><li>Fixes the displayed message of direct attached NVMe firmware flashing to align FW activation result by OS.</li></ul>","Lang":"cn"}],"Version":"HPK5"}],"SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"81a0178ad61c4266ba2c2e5a85a13a6a"}]},{"ProductId":"b80afd72e0994f04bb439cddf1f507eb","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td><td>14.32.1900</td><td>HPE0000000038</td></tr></tbody></table>"}],"Files":[{"Bytes":"17569739","DateModified":"2025-03-05T01:53:35","FileList":["/CP064990.vmexe64","/CP064990.vmfile","/CP064990.xml","/CP064990_VMw.zip","/payload.json","/README.txt","/CP064990_VMw.zip/index.xml","/CP064990_VMw.zip/vendor-index.xml","/CP064990_VMw.zip/metadata.zip","/CP064990_VMw.zip/vib20/CP064990/HPE_bootbank_CP064990_1.0.2-1OEM.900.0.24580437.vib","/CP064990_VMw.zip/metadata.zip/vendor-index.xml","/CP064990_VMw.zip/metadata.zip/vmware.xml","/CP064990_VMw.zip/metadata.zip/vibs/CP064990-8141950532340814595.xml","/CP064990_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064990_1.0.2-1OEM.900.0.24580437.xml"],"MD5Sum":"37e6f56cd21679b6d6f1eecad83e09a6","Name":"CP064990.zip","Release":"2025-03-05T01:55:03","Revision":"","SHA1Sum":"3cd894673fe4a1481584154f4b87342407eb3efa","SHA256Sum":"40baadee29ed1955e095edd4971a9c79d6f24d905647954e2d421319b89084c4","Size":"16MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.0","VibList":[{"Name":"CP064990","Version":"1.0.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"ja","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"},{"Lang":"cn","Value":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p><p>&nbsp;</p><p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />&nbsp; &nbsp; Download the appropriate SPP<br />&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />&nbsp; &nbsp; Run SUM<br />&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p><p>&nbsp;</p><p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p><p>&nbsp;</p><p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p><p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />Login as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />Place the Smart Component in a temporary directory (Example /tmp/)<br />Check if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />If the module is not loaded, use this command to load the module: vmkload_mod nmst<br /><br />Unzip the component.</p><p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe64 file:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe64</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">OR</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p><p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />&nbsp;</p><p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Logout.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p><p style=\"margin-left:80px\">&nbsp;</p><p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"Lang":"cn","Value":"Online Firmware Upgrade Utility (ESXi 9.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1015","SubDev":"02C1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159002c1","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-09T05:31:08","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following device has been updated to 14.32.1900:</strong></p><ul><li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p>","Lang":"cn"}],"Version":"1.0.0"}],"SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0fe16d5ce86d40a4ad67c0a96dd3d555"}]},{"ProductId":"18633ffffaeb4435bcda138419e66c7a","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.50 (04/17/2025)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11891312","DateModified":"2025-04-18T12:24:03","FileList":["cp066821.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_3.50_04_17_2025.signed.flash"],"MD5Sum":"5f508f341e8a6efa240c9fe3665e1c8b","Name":"cp066821.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"ea0f9769973c8932cb6e5cb665547ab99874516b","SHA256Sum":"a096dc224957c0d0b4f44c6602d0e5b595c69a4841dfd9749be4fe715864acac","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> </p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;</p><p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34)サーバー "},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:55:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"e4c258490e934f0a990926f19f6e7468"}]},{"ProductId":"e9a54d5b255e4c18936eebffaaff1ccf","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"Provides out of band management system with OS-level Agentless Management information and Active Health System events. "},{"Lang":"cn","Value":"提供具有操作系统级Agentless Management信息和Active Health系统事件的带外管理系统。 "},{"Lang":"ja","Value":"帯域管理システム以外を、OS-レベルエージェントレス管理情報とアクティブヘルスシステムのイベントで提供します。 "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li><li>Recommend user enables code integrity policy after AMS installed.</li><li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li><li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li><li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>"},{"Lang":"ja","Value":"<ul><li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li><li>ユーザーはAMSのインストール後にコード整合性ポリシーを有効にすることを推奨します。</li><li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li><li>iLO5暗号化がSuiteB NSAモードに設定されているときは、AMSコントロールパネルアプレットの[SNMP]タブに<br />  SNMP設定が表示されず、テストトラップ生成が許可されません。  iLO5->マネジメントページを代替オプションとして使用してください</li><li>AMSは、Windowsタスクマネージャーでゆっくりとしたメモリ消費量の増加を示す場合があります。これは、Microsoft WindowsのWMI（Windows Management Instrumentation）の既知の問題によるものです。今後のMicrosoft Windowsのアップデートまたはバージョンで修正される予定です。メモリ消費を遅くするには、次のいずれかを実行します。</li></ul><p>             1. AMSサービスを再起動します（コマンドプロンプトで'net stop ams'と入力し、次に'net start ams'と入力します）...または...</p><p>             2. レジストリのHKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\ParametersにPollIntervalという名前の新しいDWORDレジストリ値を作成し、その値を10進数の300より大きい値に設定します。この値により、AMSがWMIからデータを読み取る頻度（秒単位）が決定されます。</p>"},{"Lang":"cn","Value":"<ul><li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li><li>Recommend user enables code integrity policy after AMS installed.</li><li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li><li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li><li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li></ul><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>"}],"Files":[{"Bytes":"26827760","DateModified":"2025-05-21T07:13:50","FileList":["ams.cab","ams.msi","cp066437.xml","cpqsetup.exe","install.xml","multisetup.dll","SmaInstall.cab","VC_redist.x64.exe"],"MD5Sum":"9ef6d629921a9dcb131f001174e6eb2b","Name":"cp066437.exe","Release":"2025-05-21T07:11:01","Revision":"","SHA1Sum":"7a78d515a92ccb1065961dafa0b820364fd959bc","SHA256Sum":"60d7ad2cdae5322904c4a210bc577a6b1d2a5ea398e0eca5c00beafb9b83b34a","Size":"25MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"TypeOfChange":"1","Version":"2.60.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"/verbose_log","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the service installation.</p>"},{"Lang":"ja","Value":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p><p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p><p>インストールボタンをクリックしてサービスのインストールを実行します。</p>"},{"Lang":"cn","Value":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p><p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p><p>Click the &quot;Install&quot; button to perform the service installation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Agentless Management Service for Microsoft Windows x64"},{"Lang":"cn","Value":"Agentless Management Service for Microsoft Windows x64"},{"Lang":"ja","Value":"Agentless Management Service for Microsoft Windows x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33061590027f","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"027F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-33071590027f","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-04-24T07:47:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2.60.2.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで機能強化された内容については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題については、<a href=\"http://www.hpe.com/support/AMS-en\">AMSリリースノート</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the enhancements in this release.</p>","Fixes":"<p>See the <a href=\"http://www.hpe.com/support/AMS-en\">AMS Release Notes&nbsp;</a>for information about the issues resolved in this release.</p>","Lang":"cn"}],"Version":"2.60.3.0"}],"SWKeys":[{"Name":"ams.exe","SWKeyExpectedPath":"%ProgramFiles%\\OEM\\AMS\\service"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"9dc3b5318c8f478d9a5329038145f20d"}]},{"ProductId":"aa9211e645514db69ecc4a92d0863429","Versions":[{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージには、ProLiant Gen10Plus NVMeストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"37637","DateModified":"2022-07-08T11:47:29","FileList":["ISS_NVMe_BP_PIC_flashV1B24.xml","ISS_NVMe_BP_PIC_flashV1B24_signed.hex","payload.json"],"MD5Sum":"6ece3524972bf147229b1f5f043ae0a2","Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","Release":"2022-07-08T11:43:54","Revision":"E","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","Size":"36KB","TargetGUIDs":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"TypeOfChange":"1","Version":"1.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p> </p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"},{"Lang":"ja","Value":"ファームウェアパッケージ - Gen10 NVMe Backplane PICファームウェア"},{"Lang":"cn","Value":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2022-08-07T10:20:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support HPE ProLiant DL325 Gen10 Plus Server</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>HPE ProLiant DL325 Gen10 Plusサーバーをサポート</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Support HPE ProLiant DL325 Gen10 Plus Server</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.24"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi8.0</p>","Fixes":"","Lang":"cn"}],"Version":"1.24"}],"SWKeys":[{"Name":"NVMePIC-Gen10","SWKeyExpectedPath":"firmware:nvmebackplane"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"VersionId":"fd4644ff6898456b8bf5d3a92e550bfa"}]},{"ProductId":"2bd1c3f2d559498081c13ef5a6c74bb4","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.60 (05/16/2025)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.60_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.60 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"8764505","DateModified":"2025-05-20T21:03:13","FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/CP067181.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/U48_3.60_05_16_2025.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u48-3.60_2025_05_16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067181.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067181.scexe"],"MD5Sum":"eae89fee9e12c7560ddc86b7d6d5e8b5","Name":"firmware-system-u48-3.60_2025_05_16-1.1.x86_64.rpm","Release":"2025-05-21T01:55:07","Revision":"","SHA1Sum":"bbed31e87bc18bbe328df9860ab441f9f71eede2","SHA256Sum":"4cb091453dda3521d6453e825e2c82439459fa9d69052a4e8f5be648134bdf62","Size":"8MB","TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.60_05-16-2025"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner<strong>.</strong></p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br /><br /><br />サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<strong></strong></p>"},{"Lang":"cn","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br /><br /><br /><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner<strong>.</strong></p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:44:00","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>データ損失のリスクをユーザーに警告するために、すべてのIntelligent Provisioningブートパスにポップアップメッセージを追加しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>このバージョンのシステムROMには、Intel製品アップデート(IPU)バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア05.01.05.005と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの関連性：</strong></p><p>なし</p><p><strong>修正された問題点：</strong></p><p>システムユーティリティ言語が日本語に設定されている場合に、システムiLOリモートコンソールがハングする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Added pop-up message for all Intelligent Provisioning boot paths to warn users of the risk of data loss.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2025.1 guidance. This&nbsp;version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system iLO remote console might hang when the System Utilities Language is set to Japanese.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.52_02-21-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p><p>Removed Expired SUSE and Vmware Certificates.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Mehlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 05.01.05.005.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.60_05-16-2025"}],"SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3096933d9b6f4387920bcbe738a69340"}]},{"ProductId":"43151427676f44dcaced68356cf6359c","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."},{"Lang":"ja","Value":"この製品は、VMware vSphere 8.0上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"},{"Lang":"cn","Value":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 8.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"ja","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"},{"Lang":"cn","Value":"<p>This product contains driver version&nbsp;1.12.2.0</p>"}],"Files":[{"Bytes":"140880","DateModified":"2025-03-05T03:47:21","FileList":["/cp066052.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vib20/igbn/INT_bootbank_igbn_1.12.2.0-1OEM.800.1.0.20613240.vib","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vmware.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vibs/igbn--4585876958502114762.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/bulletins/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240.xml"],"MD5Sum":"4fc99fa497b8339f434cde2e25db2b3d","Name":"cp066052.zip","Release":"2025-03-05T03:24:04","Revision":"","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","Size":"137KB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"igbn","Version":"1.12.2.0-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"maintenancemode=true","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"},{"Lang":"ja","Value":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用するには、以下の手順に従ってください。</strong></p><ol><li>適切なHPE Service Pack for ProLiantベースラインをダウンロードします</li><li>ISOのSUMを使用して、コンポーネントファイルをService Pack for ProLiantに追加し、新しいカスタムISOを作成します</li><li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているサーバーに新しいService Pack for ProLiantをマウントします</li><li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li><li>リモートターゲットノードとしてアップデート対象のESXiホストを追加します</li><li>アップデート対象のESXiホストのIPアドレスまたはホスト名を入力し、その後ESXiホストの資格情報を入力します</li><li>ノードインベントリページで、追加されたコンポーネントを含む追加パッケージとService Pack for ProLiantベースラインの両方を選択します。</li><li>Smart Update Managerの指示に従い、サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してアップデートを完了します。</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のSmart Update ManagerおよびiSUTのドキュメントを参照してください。</li></ol><p><strong>VMware Toolsを使用してドライバーをアップデート。</strong></p><ol><li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li><li>オフラインバンドルをインストールするために、VMware vSphere Lifecycle Managerまたはesxcliコマンドを使用します。</li><li>vSphere Lifecycle Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li></ol><p><strong>HPE OneViewおよびHPE Smart Update Toolを使用してドライバーをアップデートするには。</strong></p><ol><li>HPE Service Pack for ProLiantベースラインとコンポーネントファイルをHPE OneViewにアップロードします</li><li>ホットフィックスコンポーネントを含むカスタムファームウェアバンドルを作成します</li><li>カスタムベースラインを論理エンクロージャー、サーバープロファイル、またはサーバープロファイルテンプレートに適用します</li><li>サーバーでSmart Update Toolsを構成するとともに、Smart Update Toolsを使用してプロファイルインストール方法ファームウェアとOSドライバーを選択し、カスタムベースラインからドライバーをインストールします</li><li>詳細な手順については、<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a>のHPE OneViewオンラインヘルプおよびiSUTのドキュメントを参照してください</li></ol>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant:</strong></p><ol><li>Download the appropriate&nbsp;HPE Service Pack for ProLiant baseline</li><li>Add the component files to the&nbsp;Service Pack for ProLiant using SUM from the ISO to create a new custom ISO</li><li>Mount the&nbsp;new&nbsp;Service Pack for ProLiant on a server running Windows or Linux that has a network connection to the ESXi host to be updated</li><li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li><li>Add the ESXi host to be updated as a remote target node</li><li>Enter the IP address or hostname of the ESXi host to be updated followed by the ESXi host credentials</li><li>Select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the update using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the Smart Update Manager and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol><p><strong>To update the driver using VMware tools:</strong></p><ol><li>Unzip this HPE component to extract the driver offline bundle</li><li>Use VMware vSphere Lifecycle Manager or esxcli commands to install the offline bundle.</li><li>Refer to VMware documentation for information on vSphere Lifecycle Manager and the esxcli commands</li></ol><p><strong>To update the driver using HPE OneView and the HPE Smart Update Tool:</strong></p><ol><li>Upload the HPE Service Pack for ProLiant baseline and the component files into HPE OneView</li><li>Create a custom firmware bundle that includes the hotfix components</li><li>Apply the custom baseline to a logical enclosure, server profile, or server profile template</li><li>Install the driver from the custom baseline by choosing the profile installation method Firmware and OS Driver using Smart Update Tools along with configuring Smart Update Tools on the server</li><li>Refer to the HPE OneView online help and iSUT documentation for detailed instructions at&nbsp;<a href=\"https://www.hpe.com/info/SmartUpdate/docs\">https://www.hpe.com/info/SmartUpdate/docs</a></li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel igbn Driver for VMware vSphere 8.0"},{"Lang":"ja","Value":"HPE Intel igbnドライバーfor VMware vSphere 8.0"},{"Lang":"cn","Value":"HPE Intel igbn Driver for VMware vSphere 8.0"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"512"},"SupportedDevices":[{"Dev":"1523","SubDev":"1989","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1523103c1989","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00FF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1521159000ff","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"337F","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c337f","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"339E","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c339e","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"17D1","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c17d1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"3380","SubVen":"103c","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c3380","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"8157","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1521103c8157","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A1","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a1","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"00A3","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-1521808600a3","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"},{"Dev":"1521","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152100000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-03T05:21:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product added support to new Gen11 servers.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>この製品では、新しいGen11サーバーのサポートを追加しました。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product added support to new Gen11 servers.</p>","Fixes":"","Lang":"cn"}],"Version":"2024.09.00"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2025.05.00"}],"SWKeys":[{"Name":"Intel-igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"J10","Model":"HP ProLiant ML10 v2 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"91eedfc8544c413bbd1e5e7e2f1c20f9"}]},{"ProductId":"787f189347ac420fbe52f5e6292d569d","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWKGU"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"20644331","DateModified":"2025-03-06T16:35:22","FileList":["/CP065986_BUILD_2.data","/CP065986.vmexe64","/CP065986.vmfile","/CP065986_VMw.zip","/CP065986.xml","/payload.json","/CP065986_VMw.zip/index.xml","/CP065986_VMw.zip/vendor-index.xml","/CP065986_VMw.zip/metadata.zip","/CP065986_VMw.zip/vib20/CP065986/HPE_bootbank_CP065986_HPD2.2-1OEM.800.1.0.20613240.vib","/CP065986_VMw.zip/metadata.zip/vendor-index.xml","/CP065986_VMw.zip/metadata.zip/vmware.xml","/CP065986_VMw.zip/metadata.zip/vibs/CP065986-8432470268618342014.xml","/CP065986_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065986_HPD2.2-1OEM.800.1.0.20613240.xml"],"MD5Sum":"72ee3e2881115c5cec547e7b46d23c5b","Name":"CP065986.zip","Release":"2025-03-06T16:34:32","Revision":"F","SHA1Sum":"401f99cd7e109f234e861f2b67e8c9d77bc03a2d","SHA256Sum":"766c65ec647d96187189b33f6d2e559f1b14699ca468cc32f05a393cde19b75f","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP065986","Version":"HPD2.2-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP041492.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p><p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWKGUドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB004000JWKGU","TargetGUID":"4d2340a5-3042-3430-3030-304a574b4755","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T13:27:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4adaf2607e844265be77d76abccb13f8"}]},{"ProductId":"25bee0f636714c0e8bface2301234fec","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.2566"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.2566"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Windows x86_64 platform."},{"Lang":"ja","Value":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作) ConnectX6デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>InfiniBand Card Type</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td><td>20.43.2566</td><td>HPE0000000034</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td><td>20.43.2566</td><td>HPE0000000035</td></tr><tr><td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td><td>20.43.2566</td><td>HPE0000000036</td></tr></tbody></table>"}],"Files":[{"Bytes":"29328720","DateModified":"2025-06-16T11:11:11","FileList":["cp067550.xml","cpqsetup.exe","fw-ConnectX6-rel-20_43_2566-P06154-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_2566-P06250-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_2566-P06251-B21_Ax-UEFI-14.37.13-FlexBoot-3.7.500.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"MD5Sum":"a3b319ec05b4230b7a162e89e8e1889c","Name":"cp067550.exe","Release":"2025-06-16T11:08:59","Revision":"","SHA1Sum":"dcb5fb6c830e5c374d01cd009b5c8779e9ceb3ef","SHA256Sum":"fb3f54a0558bad6ad892df655a1e36454232e8d44c8acd3060e7325feb76fdde","Size":"27MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.0.14"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.11"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p><p>From that drive and directory, execute the downloaded file.</p><p>Click the Install button to proceed with the installation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform"},{"Lang":"ja","Value":"Online Firmware Upgrade Utility (Windows x64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"27000"},"SupportedDevices":[{"Dev":"101B","SubDev":"02AB","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ab","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AE","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002ae","Type":"pci","Ven":"15b3"},{"Dev":"101B","SubDev":"02AF","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101b159002af","Type":"pci","Ven":"15b3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-11T11:49:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが20.43.2026にアップデートされました。</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-HDATアダプター- P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートQSFP56 PCIe3 x16 MCX653105A-ECATアダプター- P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートQSFP56 PCIe3 x16 MCX653106A-ECATアダプター- P06251-B21</li></ul><p>セキュリティ強化の機能改善 - このリリースには、重要な信頼性の向上とセキュリティ強化の機能改善が含まれています。HPEでは、デバイスのファームウェアのセキュリティと信頼性を向上させるために、デバイスのファームウェアをこのリリースにアップグレードすることを推奨します。</p><p> </p><p><strong>バージョン20.43.2026には、変更も新機能も含まれていません。</strong></p>","Fixes":"<p><strong>以下の問題点がバージョン20.43.2026で修正されました：</strong></p><ul><li>サードパーティ製スイッチとのリンクアップの問題 (BCM53405)。</li><li>競合状態を解決するためにCQ参照カウンターのアンダーフローを伴うファームウェアアサーション0x889fが発生する参照カウンターの問題。</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2026:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2026.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2026:</strong></p><ul><li>A linkup issue vs a 3rd party switch (BCM53405).</li><li>A reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition.</li></ul>","Lang":"cn"}],"Version":"1.0.0.13"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 20.43.2566:</strong></p><ul><li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li><li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li></ul><p>Security Hardening Enhancements: This release contains important reliability improvements and security hardening enhancements. HPE recommends upgrading your device&#39;s firmware to this release to improve the firmware security and reliability of your device.</p><p>&nbsp;</p><p><strong>No changes or new features have been included in version 20.43.2566.</strong></p>","Fixes":"<p><strong>The following issues have been fixed in version 20.43.2566:</strong></p><ul><li>Resolved an issue that caused the SLRG register to be unreadable when using the SMP AccessRegister MAD.</li></ul>","Lang":"cn"}],"Version":"1.0.0.14"}],"SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"7afb11bacfba46a0be5e1c9e206d542d"}]},{"ProductId":"b0391b3a14de43ee99f90e7fe9de4040","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.42_06_13_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.42 (06/13/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"33600189","DateModified":"2025-06-16T02:43:15","FileList":["payload.json","U56_2.42_06_13_2025.signed.flash","U56_2.42_06_13_2025.xml"],"MD5Sum":"20966da2842c9b0400ba3c7a7bd2c759","Name":"U56_2.42_06_13_2025.fwpkg","Release":"2025-06-16T02:39:21","Revision":"","SHA1Sum":"8660e2a0816a92633d8e03671438d953d4e1043d","SHA256Sum":"769124b53ad17eea068bda9eb69f05944d301e7039013663ada994cd7525af24","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"1","Version":"2.42_06-13-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>を参照してください。</p><p>ローカルホストOSの例：<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p><br />このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li><strong>USB Key Creator Utility</strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>"},{"Lang":"cn","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"https://www.hpe.com/info/resttool\">https://www.hpe.com/info/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p><br />This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong>USB Key Creator Utility</strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p><p>Reboot your system for the update to take effect immediately.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"Lang":"ja","Value":"ROMフラッシュファームウェアパッケージ - HPE DL110 Gen10 Plus Telco（U56）サーバー"},{"Lang":"cn","Value":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-16T02:39:03","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.04.04.702（2.30_01_06_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>RBSUシステム情報でシステムのIntel PCHモデル名が不明になる問題に対処しました。</p><p>システムDIMMを削除した後に、サーバー構成ロック検出ログに間違ったDIMMインデックスが記録される可能性がある問題に対処しました。</p><p>システムiLORestがタイムアウトする可能性がある問題に対処しました。</p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.04.04.702 (2.30_01_06_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system Intel PCH model name is unknown in RBSU System information.</p><p>Addressed an issue where the system might log into the wrong DIMM index in the Server Configuration Lock detection log after removing the system DIMM.</p><p>Addressed an issue where the system iLORest might time out. </p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_04-18-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Added Uncore Frequency RAPL to system RBSU (System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Uncore Freq RAPL).</p>","Fixes":"<p><strong>Important Notes:</strong></p><p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Maximum/Minimum Uncore Frequency values might still be configurable when Uncore Frequency Scaling is set to AUTO from OneView.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.42_06-13-2025"}],"SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"6f57949889bd480c8347287baaca7fde"}]},{"ProductId":"009bd5d739814a67a018565d835c45f1","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.50_04_17_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.50 (04/17/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"11591080","DateModified":"2025-04-18T14:17:45","FileList":["cp066845.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_3.50_04_17_2025.signed.flash"],"MD5Sum":"83fdb7212788f5b397a5ee21ad8c4166","Name":"cp066845.exe","Release":"2025-04-25T00:00:00","Revision":"","SHA1Sum":"dde1834ae5cd039e79fb804fdffe1b448c423a49","SHA256Sum":"7ebfa52e2e4bb8cc3190527e3a0630635f7965297beb00a287ac136aaf178a45","Size":"11MB","TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.50_04-17-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML350 Gen10 (U41) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-12T05:56:20","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア04.01.05.105と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p> なし","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message \"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\".</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.50_04-17-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>期限切れのSUSEおよびVMwareの証明書を削除しました。</p><p>UEFI HBA検出プロセス中の特定のPCIeカードの検出と相互作用を改善しました。</p>","Fixes":"<p><strong>重要な注記：</strong></p><p>このバージョンのシステムROMには、Intel IPU 2025.2アップデートに合わせたアップデートが含まれています。</p><p>このバージョンのシステムROMは、Server Platform Services (SPS) ファームウェア04.01.05.105と組み合わせる必要があります。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>システムに誤ったIMLメッセージ\"Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM\"が表示される可能性がある問題に対処しました。</p><p>再起動後にシステムがBitLockerリカバリをトリガーする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Removed Expired SUSE and Vmware Certificates.</p><p>Improved detection and interaction with certain PCIe cards during UEFI HBA discovery process.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This version of the System ROM contains updates aligned with the Intel IPU 2025.2 updates.</p><p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 04.01.05.105.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might have false IML message &quot;Processor X, DIMM Y - This NVDIMM is NOT a HPE SmartMemory NVDIMM&quot;.</p><p>Addressed an issue where the system might trigger BitLocker Recovery after reboot.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.50_04-17-2025"}],"SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"d307b6f4d26c47f5a1786eaf1a9993c5"}]},{"ProductId":"1065be4a2b444fe1b0060c3a91fcbde2","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."},{"Lang":"ja","Value":"この製品には、Red Hat Enterprise Linux 9で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"},{"Lang":"cn","Value":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 9."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<ul><li>&nbsp; &nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf) to (ixgbevf). Now we revert this change from (ixgbevf) to (<strong>hp</strong>-ixgbevf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbevf and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbevf and then install the updated RPM.</p>"},{"Lang":"ja","Value":"<ul><li>    このコンポーネントは、同じOSメジャーバージョンでの一貫性を保つために、RPM形式を古いバージョンにフォールバックします。</li></ul><p style=\"margin-left:40px\">* 以前のWebリリースkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmは公開されていません<br />    - RPMパッケージ名は（<strong>hp</strong>-ixgbevf）から（ixgbevf）に変更されました。この変更を（ixgbevf）から（<strong>hp</strong>-ixgbevf）に戻しました。<br />    - 新しいRPMリリースは、次の新しいOSメジャーリリースまで延期されます<br />* kmod-<strong>hp</strong>-ixgbevfとkmod-ixgbeareはOSの異なるRPMパッケージです。それらは同時にまとめてインストールすることができます。<br />  混乱を避けるため、すでにkmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpmをダウンロードしてインストールしている場合は、#rpm -e kmod-ixgbevfによって以前のRPMをアンインストールしてから、アップデートされたRPMをインストールしてください。</p>"},{"Lang":"cn","Value":"<ul><li>&nbsp; &nbsp; This component fallback the RPM format to old version for consistency in the same OS major version.</li></ul><p style=\"margin-left:40px\">* The previous web release kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm is unpublished<br />&nbsp; &nbsp; - The RPM package name was changed from (<strong>hp</strong>-ixgbevf) to (ixgbevf). Now we revert this change from (ixgbevf) to (<strong>hp</strong>-ixgbevf).<br />&nbsp; &nbsp; - The new RPM release is deferred to next new OS major release<br />* kmod-<strong>hp</strong>-ixgbevf and kmod-ixgbeare different RPM package for OS. They can be together installed in the same time.<br />&nbsp; To avoid confusion, if you already download and install kmod-ixgbevf-4.18.7-1.rhel9u2.x86_64.rpm, please uninstall the previous RPM by #rpm -e kmod-ixgbevf and then install the updated RPM.</p>"}],"Files":[{"Bytes":"79828","DateModified":"2025-04-01T09:00:09","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-427.13.1.el9_4.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/ba605e40cee3030e66921b14d1753cd234e8e7","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"MD5Sum":"9137718aea812f50d8b1b02881ab6ad2","Name":"kmod-hp-ixgbevf-4.21.25-1.rhel9u4.x86_64.rpm","Release":"2025-04-01T08:54:05","Revision":"","SHA1Sum":"55057db06d5cb9b1b26a3237236d9dd04f9c45d2","SHA256Sum":"d8fffee94ad0f28d79a8a80b9e9bb55cecd6f2e89584f96e22e550434c40bf46","Size":"77KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"4.21.25-1"},{"Bytes":"79449","DateModified":"2025-04-01T09:04:23","FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-503.11.1.el9_5.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/5ff10690dced77de757c4ed0f5ed3177758756","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"MD5Sum":"a4d032e528e550da852a74e74a5a4bf4","Name":"kmod-hp-ixgbevf-4.21.25-1.rhel9u5.x86_64.rpm","Release":"2025-04-01T08:54:05","Revision":"","SHA1Sum":"1fae2db616a076021830897ffd7a6a2844258e2d","SHA256Sum":"4c100efdf1471b6d18ed6d3115fd501400f23180ebc578086db20488e772cc67","Size":"77KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"4.21.25-1"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"Lang":"ja","Value":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"Lang":"cn","Value":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Optional"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"},{"Lang":"ja","Value":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p><p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p><p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>"},{"Lang":"cn","Value":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p><p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p><p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9"},{"Lang":"ja","Value":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 9"},{"Lang":"cn","Value":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10FB","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10FB","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10fb103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"192D","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c192d","Type":"pci","Ven":"8086"},{"Dev":"1528","SubDev":"211A","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-1528103c211a","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d2","Type":"pci","Ven":"8086"},{"Dev":"1563","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1563159000d1","Type":"pci","Ven":"8086"},{"Dev":"152E","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-152E00000000","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D0","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d0","Type":"pci","Ven":"8086"},{"Dev":"10ED","SubDev":"17D3","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-8086-10ed103c17d3","Type":"pci","Ven":"8086"},{"Dev":"1530","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-8086-153000000000","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-17T09:05:41","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>この製品は、カーネルのコンパイルの問題を修正します。</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>This product fixes the kernel compilation issue.</p>","Lang":"cn"}],"Version":"4.20.5-1"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Red Hat Enterprise Linux 9.5.</p>","Fixes":"","Lang":"cn"}],"Version":"4.21.25-1"}],"SWKeys":[{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"d0be4ccbc1614f84bed735fd74805cac"}]},{"ProductId":"386eb9df6414454ca63bfe17b21ac760","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:<br />&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p><p><strong>Release Version and/or Date:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p><p><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp;&nbsp; HPD7</p><p><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp;&nbsp; HPD7<br /><br /><strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p><p><strong>Enhancements/New Features :</strong></p><ul><li>Added support for ESXi 9.0</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>"}],"Files":[{"Bytes":"20215793","DateModified":"2025-03-06T07:51:08","FileList":["/CP066008_BUILD_3.data","/CP066008.vmexe64","/CP066008.vmfile","/CP066008_VMw.zip","/CP066008.xml","/payload.json","/CP066008_VMw.zip/index.xml","/CP066008_VMw.zip/vendor-index.xml","/CP066008_VMw.zip/metadata.zip","/CP066008_VMw.zip/vib20/CP066008/HPE_bootbank_CP066008_HPD8.3-1OEM.800.1.0.20613240.vib","/CP066008_VMw.zip/metadata.zip/vendor-index.xml","/CP066008_VMw.zip/metadata.zip/vmware.xml","/CP066008_VMw.zip/metadata.zip/vibs/CP066008--9042039589112603064.xml","/CP066008_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066008_HPD8.3-1OEM.800.1.0.20613240.xml"],"MD5Sum":"c75acfac143bf8e1dbb25f50a153b4c5","Name":"CP066008.zip","Release":"2025-03-06T07:50:18","Revision":"C","SHA1Sum":"7194fd4985fc536914a14d387ba6a2de90628d51","SHA256Sum":"5cb69e0d9449837a9192dbb2e9654e9b0a6591b0cafcbf71ec8509c83b585664","Size":"19MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP066008","Version":"HPD8.3-1OEM.800.1.0.20613240"}]}],"Installation":{"Command":"CP043259.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US\">https://support.hpe.com/hpesc/public/docDisplay?docId=a00026884en_us&amp;docLocale=en_US</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MB006000JWWQN","TargetGUID":"4d2340a5-3042-3630-3030-304a5757514e","Type":"sas"},{"Id":"MB008000JWWQP","TargetGUID":"4d2340a5-3042-3830-3030-304a57575150","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-25T15:07:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD8"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD8"}],"SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"14ca93ffa5f94a888d3e2e649aaea7a8"}]},{"ProductId":"188764648e874fd98523f669c6e5a042","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2022で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"1662936","DateModified":"2025-02-19T05:46:15","FileList":["cp064926.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"MD5Sum":"abd12703cecd5178c4a64695b95658da","Name":"cp064926.exe","Release":"2025-02-19T05:32:13","Revision":"C","SHA1Sum":"9239ff1837b4418208166c8a67866c0e36e5ffc4","SHA256Sum":"eb54e07b9b11f8a8ac0ee794cee8b38b34d5501c0b7c95edf70119cc8d9fe279","Size":"1MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.15.121.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Intel icea Driver for Microsoft Windows Server 2022"},{"Lang":"ja","Value":"Intel iceaドライバーfor Microsoft Windows Server 2022"},{"Lang":"cn","Value":"Intel icea Driver for Microsoft Windows Server 2022"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3200"},"SupportedDevices":[{"Dev":"1592","SubDev":"0002","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860002","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"0006","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159280860006","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0003","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860003","Type":"pci","Ven":"8086"},{"Dev":"159B","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159b80860005","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"0005","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-159380860005","Type":"pci","Ven":"8086"},{"Dev":"1592","SubDev":"000E","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15928086000e","Type":"pci","Ven":"8086"},{"Dev":"1593","SubDev":"000C","SubVen":"8086","TargetGUID":"a6b1a447-382a-5a4f-8086-15938086000c","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-06T05:57:25","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product enhanced the compatibility with firmware of Columbiaville 4.5.</p>","Fixes":"<ul><li>This product correct an issue which seeing warning message Event ID : 101 with ICEA module.</li><li>This product correct an issue which E810 physical adapter does not display RDMA counters.</li></ul>","Lang":"en"},{"Enhancements":"<p>この製品は、Columbiaville 4.5のファームウェアとの互換性を強化しました。</p>","Fixes":"<ul><li>この製品は、ICEAモジュールで警告メッセージイベントID：101 が表示される問題を修正します。</li><li>この製品は、E810物理アダプターがRDMAカウンターを表示しない問題を修正します。</li></ul>","Lang":"ja"},{"Enhancements":"<p>This product enhanced the compatibility with firmware of Columbiaville 4.5.</p>","Fixes":"<ul><li>This product correct an issue which seeing warning message Event ID : 101 with ICEA module.</li><li>This product correct an issue which E810 physical adapter does not display RDMA counters.</li></ul>","Lang":"cn"}],"Version":"1.15.121.0"},{"ReleaseNotes":[{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product now supports Azure Stack HCI OS.</p>","Fixes":"","Lang":"cn"}],"Version":"1.15.121.0"}],"SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000t Converged Edge System"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"","Model":"HPE Edgeline EL8000 Converged Edge System"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"H09","Model":"HPE ProLiant m750 Server Blade"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"","Model":"HPE Cray XD220v"},{"Family":"","Model":"HPE Cray XD295v"},{"Family":"","Model":"HPE Cray XD225v"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"03030201","Model":"HPE Compute Scale-up Server 3200"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"","Model":"HPE Cray XD665"},{"Family":"","Model":"HPE Cray XD670"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"A59","Model":"HPE ProLiant Compute XD685"},{"Family":"U66","Model":"HPE ProLiant Compute XD230"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"99d02b411ae743f99d65ff8c8748b77e"}]},{"ProductId":"5c045315a07d45779f552f6cb831a2b4","Versions":[{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.4030"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1900"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1900"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Linux Operating Systems."},{"Lang":"cn","Value":"此软件包含有用于升级在Linux操作系统下运行的仅使用太网适配器的HPE Mellanox的固件所需的实用程序和二进制程序。"},{"Lang":"ja","Value":"このパッケージは、Linuxオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains the following firmware versions:</p><table border=\"1\" cellpadding=\"1\" cellspacing=\"1\"><tbody><tr><td><strong>Mellanox Ethernet Only Adapters</strong></td><td><strong>Firmware Version</strong></td><td><strong>PSID</strong></td></tr><tr><td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td><td>14.32.1900</td><td>HP_2690110034</td></tr><tr><td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td><td>14.32.1900</td><td>HP_2420110034</td></tr><tr><td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td><td>16.35.4030</td><td>HPE0000000014</td></tr></tbody></table>"}],"Files":[{"Bytes":"8416408","DateModified":"2024-10-18T01:06:32","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/CP063095.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1900-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1900-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw/fw-ConnectX5-rel-16_35_4030-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.22-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063095.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063095.scexe"],"MD5Sum":"af1f4f90b923c125e216f524ee1391b5","Name":"firmware-nic-mellanox-ethernet-only-1.0.22-1.1.x86_64.rpm","Release":"2024-10-18T06:03:42","Revision":"","SHA1Sum":"71a681284d041a479a58e54cd749b7da092a7d88","SHA256Sum":"b596b0fcd6fee4dc8cb59a48f50b27858972bcc6df917d8754a33228590c0817","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.22"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"},{"Lang":"ja","Value":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p><ul><li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li><li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li><li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li><li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li></ul><p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p><ul><li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li><li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li><li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li></ul>"},{"Lang":"cn","Value":"<p><strong>Updating firmware with rpm installed:</strong></p><ul><li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li><li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li><li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li><li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li></ul><p><strong>Updating firmware without installing rpm:</strong></p><ul><li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li><li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li><li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters"},{"Lang":"cn","Value":"用于仅使用太网适配器的HPE Mellanox的在线固件升级实用程序（Linux x86_64）"},{"Lang":"ja","Value":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64) for HPE Mellanox Ethernetアダプター専用"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"8000"},"SupportedDevices":[{"Dev":"1017","SubDev":"0246","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-101715900246","Type":"pci","Ven":"15b3"},{"Dev":"1015","SubDev":"00D3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d3","Type":"pci","Ven":"15B3"},{"Dev":"1015","SubDev":"00D4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-15b3-1015159000d4","Type":"pci","Ven":"15B3"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-02T11:00:23","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.3502:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"en"},{"Enhancements":"<p><strong>次のデバイス用のファームウェアが14.32.1010にアップデートされました。</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2ポート640FLR-SFP28アダプター)</li><li>817753-B21 (HPE Ethernet 25Gb 2ポート640SFP28アダプター)</li></ul><p><strong>次のデバイス用のファームウェアが16.35.3502にアップデートされました。</strong></p><ul><li>874253-B21（HPE Ethernet 100Gb 1ポート842QSFP28アダプター）</li></ul><p><strong>ファームウェアバージョン14.32.1010には新機能の追加も変更もありません。</strong></p><ul><li>3つの新しいアサートフィルター(ヘルスバッファー、NVlog、FWトレース)が追加されました。重大度レベルが新しいフィルター以上の場合、アサーションが公開されます。</li><li>VM-TCではなくVM単位のレート制限を有効にしました。この機能は、新しいスケジューリング要素タイプ(rate_limitに接続し、そのレート制限を共有するレート制限要素)へのサポートを追加することによって実装されます。</li><li>PFごとの非対称VFのサポートを追加しました。有効にするには、PF_NUM_OF_VF_VALIDをtrueにし、PF_NUM_OF_VFをゼロ以外の値にする必要があります。</li><li>外部ループバック速度を、使用されているモジュールの機能に制限しました。</li><li>高速リンクアップ機能を使用する場合のリンクアップ時間を改善しました。</li><li>ゼロタッチRoCE機能を有効にするために、slow_restartおよびslow_restart_idleパラメーターのサポートが追加されました。                                                                                                                     </li></ul><p><strong>ファームウェアバージョン16.35.3502には新機能の追加も変更もありません。</strong></p><ul><li>TCP IPv4フローを変更し、ステアリングTIR rx_hash_symmetricフィールドが、SRCフィールドとDST フィールドの両方がゼロに設定されていない場合にのみ有効になるようになりました。</li></ul>","Fixes":"<p><strong>以下の問題点がファームウェアバージョン14.32.1010で修正されました。</strong></p><ul><li>RxLOSをサポートする光トランシーバーを接続し、リモート側のポートがダウンしたときに、ファームウェアは応答しない状態になり、予期しない動作が発生しました。</li><li>システムは128Kを超えるQPを作成できませんでした。</li><li>光モジュールの使用中にピアポートが停止すると、まれにシステムが応答しない状態になることがあります。</li><li>非対称VFが有効になっている場合は、パケットペーシングレートが使用されました。</li><li>rts2rts_qp移行中にRNRタイムアウトを設定しようとした場合のRNRタイムアウトが正しくありません。</li><li>ConnectX-4LXのIPSecフローでRSSに問題が発生することにより、パフォーマンスが低下します。このシナリオでは、SPIの最適化により、特定のホストからのパケットが同じCPUコアにハッシュされました。修正は、ConnectX-4Lxアダプタカードのl4_typeに従ったSPI最適化を無視することでした。</li><li>GetInventory NC-SIコマンドは、ファームウェアバージョンが0で始まっている場合に、その先頭の0xfを報告しました。</li></ul><p><strong>ファームウェアバージョン16.35.3502には修正が含まれていません。</strong></p>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.3502:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>New features and changes included in firmware version 14.32.1010:</strong></p><ul><li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li><li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li><li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li><li>Limited the external loopback speed to the used module&#39;s capabilities.</li><li>Improved linkup time when using the fast linkup capability.</li><li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li></ul><p><strong>New features and changes included in firmware version 16.35.3502:</strong></p><ul><li>Modified the TCP IPv4 flows so that the steering TIR rx_hash_symmetric field is now valid only when both the SRC and DST fields are not set to zero.</li></ul>","Fixes":"<p><strong>The following issues have been fixed in firmware version 14.32.1010:</strong></p><ul><li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li><li>The system could not create more than 128K QPs.</li><li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li><li>Packet Pacing rate was used if asymmetric VFs was enabled.</li><li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li><li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li><li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li></ul><p><strong>No fixes are included&nbsp;in firmware version 16.35.3502.</strong></p>","Lang":"cn"}],"Version":"1.0.21"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"en"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"ja"},{"Enhancements":"<p><strong>Firmware for the following devices has been updated to 14.32.1900:</strong></p><ul><li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li><li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li></ul><p><strong>Firmware for the following device has been&nbsp;updated to 16.35.4030:</strong></p><ul><li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li></ul><p><strong>Security Hardening Enhancements</strong><br />This release contains important reliability improvements and security hardening enhancements. NVIDIA recommends upgrading your devices firmware to this release to improve the devices&rsquo; firmware security and reliability.<br />&nbsp;</p><p><strong>No new features or changes have been included in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>New features and changes included in firmware version 16.35.4030:</strong></p><ul><li>Added support for postponing QP timeout &quot;retry exceeded&quot; errors for traffic&nbsp;directed at specific destinations. This new capability prevents broken&nbsp;connections for destinations in downtime because of live migration.</li></ul>","Fixes":"<p><strong>No fixes have been included&nbsp;in firmware version 14.32.1900.</strong></p><p>&nbsp;</p><p><strong>The following issues have been fixed in firmware version 16.35.4030:</strong></p><ul><li>VF FLR would get stuck when its PF triggered the FLR as well.</li><li>Unexpected source UDP port appeared in RoCE packets when the firmware ignored a non-PF driver configuration for RoCE source UDP port control (as set in SET_HCA_CAP.sw_r_roce_src_udp_port).</li></ul>","Lang":"cn"}],"Version":"1.0.22"}],"SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U22","Model":"HPE ProLiant DL20 Gen9 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U19","Model":"HPE Apollo 4200 Gen9 Server"},{"Family":"U46","Model":"HPE Apollo 4100 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U25","Model":"HPE ProLiant XL270d Gen9 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"","Model":"HPE ProLiant SL4500 Chassis"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"778c7f56c3dc40119dde23bac6fbb2d1"}]},{"ProductId":"b88ebb63a68747808884160b11c000eb","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Network"},{"Lang":"ja","Value":"ドライバ - ネットワーク"},{"Lang":"cn","Value":"驱动程序 - 网络"}],"Description":[{"Lang":"en","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"Lang":"ja","Value":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"},{"Lang":"cn","Value":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"846552","DateModified":"2024-06-13T05:41:13","FileList":["cp061748.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"MD5Sum":"6517698fb925618d20f8ac6ea879d057","Name":"cp061748.exe","Release":"2024-06-13T05:26:31","Revision":"B","SHA1Sum":"acc67f31735d26e585721f07f536a38ca7d90a6a","SHA256Sum":"a88c23504ed391971807b330e24632ad385434d0b797c5a9a5bbaab50f8247a7","Size":"826KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"TypeOfChange":"1","Version":"2.1.252.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"Lang":"ja","Value":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"},{"Lang":"cn","Value":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Intel vxs Driver for Windows Server 2019"},{"Lang":"ja","Value":"Windows Server 2019用HPE Intel vxsドライバー"},{"Lang":"cn","Value":"HPE Intel vxs Driver for Windows Server 2019"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"400"},"SupportedDevices":[{"Dev":"1565","SubDev":"00D1","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d1","Type":"pci","Ven":"8086"},{"Dev":"1564","Type":"pci","Ven":"8086"},{"Dev":"1565","SubDev":"00D2","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-8086-1565159000d2","Type":"pci","Ven":"8086"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-07-12T07:50:07","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product is updated to maintain compatibility with CNSA (Commercial National Security Algorithm) compliance.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>This product is updated to maintain compatibility with CNSA (Commercial National Security Algorithm) compliance.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>This product is updated to maintain compatibility with CNSA (Commercial National Security Algorithm) compliance.</p>","Fixes":"","Lang":"cn"}],"Version":"2.1.230.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p>TBD</p>","Lang":"cn"}],"Version":"2.1.252.0"}],"SWKeys":[{"Name":"vxs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"1c14a167e97d417dbd3e1c7fb06d59c6"}]},{"ProductId":"b61013381e514e74835819b0f29c6165","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD4"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD4"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD4"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD4"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following drive models: MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK"},{"Lang":"ja","Value":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB012000JZYVN、MB014000JZYVP、MB016000JZYVQ、MB018000JYCLK"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives</p><p><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD3<br /><br /><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Added support for Azure Stack HCI 23H2</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fix the controller library compatible issue.</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"4172360","DateModified":"2025-01-10T10:02:22","FileList":["cp065024.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09scHPD4.REL"],"MD5Sum":"58b202903fcbaafab8f8cd5d3df884e4","Name":"cp065024.exe","Release":"2025-01-10T09:58:04","Revision":"C","SHA1Sum":"4c04effa83a903a5e0b5d8754586df9c2544dc84","SHA256Sum":"93bc241b0bd9f5499e4660a4c18ebf536c03d75f62d15ab157a992da1eacc9e9","Size":"3MB","TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD4"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li></ul><p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p><ul><li>Place the desired firmware to be updated in the directory, \\\\packages.</li><li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li><li>Follow the instructions on the screen.</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li></ul><p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a>から以下の手順に従ってください：</p><ul><li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li><li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQおよびMB018000JYCLKドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"3000"},"SupportedDevices":[{"Id":"MB012000JZYVN","TargetGUID":"4d2340a5-3042-3231-3030-304a5a59564e","Type":"sas"},{"Id":"MB014000JZYVP","TargetGUID":"4d2340a5-3042-3431-3030-304a5a595650","Type":"sas"},{"Id":"MB016000JZYVQ","TargetGUID":"4d2340a5-3042-3631-3030-304a5a595651","Type":"sas"},{"Id":"MB018000JYCLK","TargetGUID":"4d2340a5-3042-3831-3030-304a59434c4b","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-10T09:06:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>コントローラーライブラリの互換性の問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Added support for Azure Stack HCI 23H2</li></ul>","Fixes":"<ul><li>Fix the controller library compatible issue.</li></ul>","Lang":"cn"}],"Version":"HPD4"}],"SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"54281078d04c4217bc3869e91e56b177"}]},{"ProductId":"8f24173ef2e740d2b110bb710e861366","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Software - System Management"},{"Lang":"ja","Value":"ソフトウェア - システム マネジメント"},{"Lang":"cn","Value":"软件 - 系统管理"}],"Description":[{"Lang":"en","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "},{"Lang":"ja","Value":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"},{"Lang":"cn","Value":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"32328738","DateModified":"2025-06-18T06:51:17","FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure21-EnableTheUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13111710.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/E715D14BC4DA8CD869191A35F5895EF8.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/32A2545A2960CF71C5CAFCD727287CA8.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/65BE937508C2D8855A90B1DED910A374.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/C06A186AA6638490D88D8C8228E0FB05.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/69764ACC5E53D6F921C992ED903FFB0F.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/A0F61DB6ED9077953D2320C3F710444B.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/b8352d861c6619aac9f7b7e9015da9d8945e09","./usr/lib/.build-id/0e","./usr/lib/.build-id/0e/f3db1217fc5acb1f86191133fe9cec97205859","./usr/lib/.build-id/13","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6.1","./usr/lib/.build-id/21","./usr/lib/.build-id/21/5f4a03530133a7c0b3a531fe0ed757ba25793e","./usr/lib/.build-id/23","./usr/lib/.build-id/23/c11840c1bc673657f2db880a585af0e0026a68","./usr/lib/.build-id/27","./usr/lib/.build-id/27/b31992b09f650c906ee209359448d9cd1edfdd","./usr/lib/.build-id/49","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623.1","./usr/lib/.build-id/59","./usr/lib/.build-id/59/ed5cf6cefde002ea5c02430d9c8ae96e8cdec1","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f.1","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/7e60ca66fa960cbe619305de801f08b4a7c6b1","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/b145842ffc11c2f256afc82345390f7da8dad9","./usr/lib/.build-id/85","./usr/lib/.build-id/85/95f1c93754946a6f51f77557bc2efc250accae","./usr/lib/.build-id/85/95f1c93754946a6f51f77557bc2efc250accae.1","./usr/lib/.build-id/96","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd.1","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/d287d1776349d330dba411f8e628865b84a93d","./usr/lib/.build-id/a2","./usr/lib/.build-id/a2/5732eeae4c0eb63f65250a5c101b220389054b","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a.1","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/241cf9760ac61bd5ab81b0102fbb205623360a","./usr/lib/.build-id/db","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157.1","./usr/lib/.build-id/df","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986.1","./usr/lib/.build-id/e6","./usr/lib/.build-id/e6/14c16894270f516cb00291b96cdb3991a2499d","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce.1","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/495e13fb1a5487dff8a254f7dd68297a95cd71","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"MD5Sum":"07b819a2d708bae82a404b5d5e091d92","Name":"MRStorageAdministrator-008.012.022.000-00.x86_64.rpm","Release":"2025-06-26T00:00:00","Revision":"","SHA1Sum":"fba22c8991cf3cef07ead2f07cb528632b3ad8bf","SHA256Sum":"8e3d0342a8c67a34dcf7112fd8a1410ff5de6fe0f7f8bc73c445318aeb1b736a","Size":"30MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.12.22.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"},{"Lang":"ja","Value":"<ul><li>HPEMRSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li><li>古いバージョンのHPEMRSAがシステムにインストールされている場合、\"rpm -e <rpm_name>\"を使用して最初にそれを削除してください。</li><li>\"rpm  -Uvh --oldpackage --replacefiles –replacepkgs <rpm_name>\"を使用してアプリケーションをインストールします。</li><li>RPMに関する詳細については \"man rpm\" と入力します。</li><li>ソフトウェアはopt/HPEMRSA/LSIStorageAuthorityにあります。</li><li>/opt/HPEMRSA/LSIStorageAuthorityにあるStartupLSAUI.shを実行して、MRSAを起動します。</li></ul>"},{"Lang":"cn","Value":"<ul><li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li><li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li><li>Use &quot;rpm -Uvh --oldpackage --replacefiles &ndash;replacepkgs &lt;rpm_name&gt;&quot; to install the application.</li><li>Please type &quot;man rpm&quot; for other details regarding RPM.</li><li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li><li>Run StartupLSAUI.sh located in /opt/HPEMRSA/LSIStorageAuthority to launch MRSA.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE MegaRAID Storage Administrator for Linux 64-bit (HPE MRSA for Gen10P and Gen11 Controllers)"},{"Lang":"ja","Value":"HPE MegaRAID Storage Administrator for Linux 64ビット（HPE MRSA for Gen10PおよびGen11コントローラー）"},{"Lang":"cn","Value":"HPE MegaRAID Storage Administrator for Linux 64-bit (HPE MRSA for Gen10P and Gen11 Controllers)"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0328","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900328","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0325","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900325","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0329","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900329","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"03C8","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0326","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900326","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"},{"Dev":"10E2","SubDev":"0448","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900448","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-08-17T04:04:05","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Debug ability improvements. All 3rdparty binaries latest version has been compiled with&nbsp;gcc 4.8.x.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li></ul>","Fixes":"<ul><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>リンク分離による電力節約のサポート。phy が有効か無効かを通知する新しいイベントを追加します。</li><li>物理ドライブが正常に動作しない場合、物理ドライブの種類に不明を追加します。</li><li>デバッグ機能の改善。すべてのサードパーティバイナリの最新バージョンは、gcc 4.8.x でコンパイルされています。</li><li>より良い冷却を実現するために、NVMe ドライブの温度ポーリングの頻度を増やします。<ul><li>サポート ビット「supportNvmeThermalPoll」とコントローラー プロパティ「NVMeThermalPollIntervalInSec」。</li><li>コントローラー メニューの「その他のアクション」に「NVMeThermalPollInterval の設定」が追加されました。</li></ul></li></ul>","Fixes":"<ul><li>LSA_MONITOR が同じイベントを繰り返し出力する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Debug ability improvements. All 3rdparty binaries latest version has been compiled with&nbsp;gcc 4.8.x.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li></ul>","Fixes":"<ul><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"cn"}],"Version":"8.12.22.0"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Debug ability improvements. All 3rdparty binaries latest version has been compiled with&nbsp;gcc 4.8.x.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li><li>Upgrade Nginx to version 1.26.</li></ul>","Fixes":"<ul><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>リンク分離による電力節約のサポート。phy が有効か無効かを通知する新しいイベントを追加します。</li><li>物理ドライブが正常に動作しない場合、物理ドライブの種類に不明を追加します。</li><li>デバッグ機能の改善。すべてのサードパーティバイナリの最新バージョンは、gcc 4.8.x でコンパイルされています。</li><li>より良い冷却を実現するために、NVMeドライブの温度ポーリングの頻度を増やします。<ul><li>サポートビット「supportNvmeThermalPoll」とコントローラープロパティ「NVMeThermalPollIntervalInSec」。</li><li>コントローラーメニューの「その他のアクション」に「NVMeThermalPollInterval の設定」が追加されました。</li></ul></li><li>Nginxをバージョン1.26へアップグレード</li></ul>","Fixes":"<ul><li>LSA_MONITOR が同じイベントを繰り返し出力する問題を修正しました。</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>Support for Link isolation power savings. Add newly event which tells phy is enable or&nbsp;disable.</li><li>Add Physical drive type Unknown for cases where Physical Drive is misbehaving.</li><li>Debug ability improvements. All 3rdparty binaries latest version has been compiled with&nbsp;gcc 4.8.x.</li><li>Increase the frequency of temperature polling for NVMe drives in order to achieve better&nbsp;cooling.<ul><li>Support Bit &quot;supportNvmeThermalPoll&quot; and Controller property&nbsp;&quot;NVMeThermalPollIntervalInSec&quot;.</li><li>Controller Menu &quot;Set NVMeThermalPollInterval&quot; added in More Actions.</li></ul></li><li>Upgrade Nginx to version 1.26.</li></ul>","Fixes":"<ul><li>Fix an issue that LSA_MONITOR outputs the same event repeatedly.</li></ul>","Lang":"cn"}],"Version":"8.12.22.0"}],"SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"A58","Model":"HPE ProLiant DL145 Gen11"},{"Family":"U72","Model":"HPE ProLiant Compute DL580 Gen12"},{"Family":"I46","Model":"HPE Synergy 480 Gen12 Compute Module"},{"Family":"U68","Model":"HPE ProLiant Compute ML350 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL360 Gen12"},{"Family":"U68","Model":"HPE ProLiant Compute DL380 Gen12"},{"Family":"","Model":"HPE ProLiant DL380m Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U72","Model":"HPE ProLiant Compute DL380a Gen12 (U72)"},{"Family":"A66","Model":"HPE ProLiant Compute DL325 Gen12 Server"},{"Family":"A66","Model":"HPE ProLiant Compute DL345 Gen12 Server"},{"Family":"U68","Model":"HPE Alletra Storage Server 4210"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"fb060b0622484975bcabed0966c87fcf"}]},{"ProductId":"64242f6035c24947925dbb84f5af8b24","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.40 (05/16/2025)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.40_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.40 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"17434120","DateModified":"2025-05-20T12:16:09","FileList":["cp067164.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U64_2.40_05_16_2025.signed.flash"],"MD5Sum":"f141bf57cea87b0e1df7f8dbbfdbc7de","Name":"cp067164.exe","Release":"2025-05-20T12:13:05","Revision":"","SHA1Sum":"487ef9db8b23a65b1d738913b25edb8031a53062","SHA256Sum":"dd721a8ab79bfcc504745cadface23f47ce9a2ff5e8de4822ad7f4c009c8254f","Size":"16MB","TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.40_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-06-14T03:32:09","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p>このバージョンのシステムROMは、Server Platform Services（SPS）ファームウェア06.00.03.700（2.30_01_07_2025）と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、次のリンクを参照してください。<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPE サポート</a>。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題点:</strong></p><p>ファームウェア管理プロトコル経由でファームウェアのアップデートを実行するときにシステムがRSODになる可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system might RSOD when performing firmware update via Firmware Management Protocol.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.34_03-11-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Tatlow IPU 2025.2 update.This version of the System ROM should be paired with Server Platform Services (SPS) Firmware 06.00.03.700 (2.30_01_07_2025).<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the system may encounter RSOD and fail to update firmware while performing firmware update.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"2.40_05-16-2025"}],"SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"FTP","Model":"FTP-Only System"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4521549d43354a3888b36ae8351ea42d"}]},{"ProductId":"effc199f67764de3b570f964be1aa0ce","Versions":[{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"Lang":"ja","Value":"このコンポーネントは、HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバーをアップデートします "},{"Lang":"cn","Value":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"6910600","DateModified":"2025-02-10T09:10:14","FileList":["cp051154.compsig","cp051154.zip","cp051155.compsig","cp051155.zip","cp065613.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"c13158bcdfb2de80fa99d0d9eca2c705","Name":"cp065613.exe","Release":"2025-02-10T09:09:10","Revision":"D","SHA1Sum":"fa166a1100a7a3723ebe0e10117e79ffb0727664","SHA256Sum":"ea7090011d763910e6dccc1ac9d27dd8aa26d47048f1d9d769177f6630ae2b2b","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br /> </p><p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p><p style=\"margin-left:0px; margin-right:0px\">オプション1：</p><ul style=\"list-style-type:disc\"><li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li><li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li></ul><p style=\"margin-left:0px; margin-right:0px\">オプション2：</p><ul><li>SPP ISOをマウントします</li><li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li><li>SUMを起動し、ベースラインライブラリパネルに移動します。</li><li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li><li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li><li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li><li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li><li>サーバーを再起動して、インストールを実行するSPPを起動します。</li></ul><p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />&nbsp;</p><p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p><p style=\"margin-left:0px; margin-right:0px\">Option1:</p><ul style=\"list-style-type:disc\"><li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li><li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li></ul><p style=\"margin-left:0px; margin-right:0px\">Option 2:</p><ul><li>Mount the SPP ISO</li><li>Copy the desired update component(s) in a temporary directory.</li><li>Start SUM and navigate to the Baseline Library panel.</li><li>Select Add from the Actions menu and add the mounted SPP.</li><li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li><li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li><li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li><li>Restart the server to boot to the SPP to perform the install.</li></ul><p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"},{"Lang":"ja","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"},{"Lang":"cn","Value":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-10T09:07:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>重要な注意：</strong></p><p>Ver 0.2.3.0(B)には、ファームウェアのパッケージングに対するアップデートが含まれており、機能的にver 0.2.3.0と同等です。ファームウェアをバージョン0.2.3.0にアップグレードするために以前のリビジョンのコンポーネントが使われた場合は、リビジョン(B)にアップグレードする必要はありません。</p><p><strong>ファームウェアの依存関係:</strong></p><p> なし</p><p><strong>修正された問題点：</strong></p><p>Innovation Engine（IE）が24時間ごとに不適切にリセットされる可能性がある問題に対処しました。一部のシステムでは、これによりCPU使用率が一時的に低下したり、ネットワークトラフィックの持続が1秒未満になったりする可能性があります。</p><p><strong>既知の問題点:</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(B) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(D) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision D if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(D) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision D if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"ja"},{"Enhancements":"","Fixes":"<p><strong>Important Notes:</strong></p><p>Ver. 0.2.3.0(D) contains updates to the firmware packaging and is functionally equivalent to ver. 0.2.3.0. It is not necessary to upgrade with Revision D if a previous component revision was used to upgrade the firmware to version 0.2.3.0.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours. On some systems this could result in a brief drop in CPU utilization or network traffic lasting less than a second.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"0.2.3.0"}],"SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"H08","Model":"HPE ProLiant e910 Server Blade"},{"Family":"H08","Model":"HPE ProLiant e910t Server Blade"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"2819e579c07f4408b797be9636f2f8bd"}]},{"ProductId":"3702e2a6624243b4a85fa9ca1f4c0ce2","Versions":[{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_3.72_05_16_2025.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v3.72 (05/16/2025)"}]},"Package":{"Category":[{"Lang":"en","Value":"BIOS - System ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"},{"Lang":"cn","Value":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"34220680","DateModified":"2025-05-21T13:17:57","FileList":["A48_3.72_05_16_2025.signed.flash","cp067155.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"MD5Sum":"57b0a22df8ee196471d51f75d7ba9bfa","Name":"cp067155.exe","Release":"2025-05-29T00:00:00","Revision":"","SHA1Sum":"1f42d049978f4d3ccf559c1149654152a82a96f9","SHA256Sum":"0763d427ede0aee668768c703fa4f94d12c696e5d64ab66b4bacc5d8ed44c6c1","Size":"32MB","TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"0","Version":"3.72_05-16-2025"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p><p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p><p><br /> サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br /> </p><p> </p>"},{"Lang":"cn","Value":"<p>To update firmware from Windows operating system on target server:</p><p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p><p><br />&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li><li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.<br />&nbsp;</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"11000"},"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-27T05:23:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Fが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの依存関係：</strong></p>なし<p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p>なし","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.F for AMD 3rd Generation EPYC processors.This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p>None","Lang":"cn"}],"Version":"3.72_05-16-2025"},{"ReleaseNotes":[{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"en"},{"Enhancements":"<p>複数言語の翻訳をアップデートしました。</p>","Fixes":"<p><strong>重要な注意：</strong></p><p>システムROMのこのリビジョンには、AMD第3世代EPYCプロセッサー用のAMDリファレンスコードMilanPI 1.0.0.Gが含まれています。システムROMのこのリビジョンには、AMD第2世代EPYCプロセッサー用のAMDリファレンスコードRomePI 1.0.0.Mが含まれています。</p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p><p><strong>ファームウェアの依存関係：</strong></p><p>なし</p><p><strong>修正された問題：</strong></p><p>特定の構成で8TBのシステムメモリがインストールされている場合、POST時にシステムがハングする可能性がある問題に対処しました。</p><p>MRコントローラーページの論理ドライブの名前フィールドが、終了してMRコントローラーページに戻った後に、失われたり意図せず変更されたりする可能性がある問題に対処しました。</p><p><strong>既知の問題点：</strong></p><p>なし</p>","Lang":"ja"},{"Enhancements":"<p>Updated multi-language translation.</p>","Fixes":"<p><strong>Important Notes:</strong></p><p>This revision of the System ROM includes AMD reference code MilanPI 1.0.0.G for AMD 3rd Generation EPYC processors. This revision of the System ROM includes AMD reference code RomePI 1.0.0.M for AMD 2nd Generation EPYC processors.</p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link&nbsp;<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p><p><strong>Firmware Dependencies:</strong></p><p>None</p><p><strong>Problems Fixed:</strong></p><p>Addressed an issue where system may hang at POST when there are 8TB system memory installed with certain configuration.</p><p>Addressed an issue where the Name field of the Logical Drive under MR controller page might be missing or changed unintentionally after exiting and going back to the MR controller page.</p><p><strong>Known Issues:</strong></p><p>None</p>","Lang":"cn"}],"Version":"3.72_05-16-2025"}],"SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"UpgradeRequirements":"Optional"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"391c05f3f59643309154acfc1b9e0bbb"}]},{"ProductId":"3eab1bf1c35b40e5b35b9f8cbcf441cd","Versions":[{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp064971.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.700"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - System"},{"Lang":"ja","Value":"ファームウェア - システム"},{"Lang":"cn","Value":"固件 - 系统 ROM"}],"Description":[{"Lang":"en","Value":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"2450011","DateModified":"2025-05-15T04:18:15","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/CP067260.xml","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/cp064971.compsig","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/cp064971.zip","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.700-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067260.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067260.scexe"],"MD5Sum":"0e765dfe48747c76dc7afb5e18f3e2d0","Name":"firmware-ml30gen10plus_me-06.00.03.700-2.1.x86_64.rpm","Release":"2025-05-15T09:11:00","Revision":"B","SHA1Sum":"ebd9079bd93a6373be339e89d6a9d0245aa6040d","SHA256Sum":"7d67cb1e548c38f89e51c1d83da5080f310d104efe049d3dc9e6b0831284ca3b","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.700"}],"Installation":{"Command":"cpqsetup","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Reboot your system for the update to take effect immediately.</p><p><strong>Verify the RPM signature using the following steps:</strong></p><p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>Import the public key while logged in as root by running the following command:</p><p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p><p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>Verify the RPM:</strong></p><p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p><p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p><p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p><p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p><p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p><p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p><p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p><ul></ul>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />コマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。</p><p>アップデートを直ちに有効にするにはシステムを再起動してください。</p><p><strong>次の手順を使用してRPM署名を確認します：</strong></p><p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：<a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p><p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします：</p><p>   # rpm --import /path_to_the_key/file_name_of_the_key</p><p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p><p><strong>RPMを検証します：</strong></p><p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p><p>   # rpm --checksig filename_of_the_rpm</p><p>   example result #  rpm --checksig <filename>.rpm</p><p>  <filename>.rpm: digests signatures OK</p><p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p><p>   # rpm --checksig sample_file.rpm</p><p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p><p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p><ul></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"Lang":"ja","Value":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"500"},"SupportedOperatingSystems":[{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-06-15T09:05:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"},{"ReleaseNotes":[{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"en"},{"Enhancements":"<p><strong>重要な注意：</strong></p>このバージョンのServer Platform Services (SPS) ファームウェアには、Intel製品アップデート (IPU) バージョンIPU.2025.1ガイダンスに沿ったアップデートが含まれています。このバージョンのSPS 06.00.03.700 (2.30_01_07_2025) は、システムROM 2.30 (01/16/2025) 以降と組み合わせる必要があります。<p><p>報告されたセキュリティ脆弱性とその緩和策の詳細については、リンク<a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">セキュリティ報告ライブラリ | HPEサポート</a>を参照してください。</p></p><p><strong>ファームウェアの関連性：</strong></p>なし<p><strong>機能強化/新しい機能:</strong></p><p>このバージョンは、IPU.2025.1ガイダンスに準拠しています。</p><p><strong>既知の問題点：</strong></p>なし","Fixes":"","Lang":"ja"},{"Enhancements":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU 2025.1 guidance.This version of the SPS 06.00.03.700 (2.30_01_07_2025) should be paired with System ROM 2.30 (01/16/2025) or later.<p><p>Details about reported security vulnerabilities and their mitigation can be found at the following link <a href=\"https://support.hpe.com/connect/s/securitybulletinlibrary?language=en_US\">Security Bulletin Library | HPE Support</a>.</p></p><p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU 2025.1 guidance.</p><p><strong>Known Issues:</strong></p>None","Fixes":"","Lang":"cn"}],"Version":"06.00.03.700"}],"SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"FTP","Model":"FTP-Only System"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"308311eb37984a578428d34af1bacd35"}]},{"ProductId":"d0558c4ca40d4c1889688fd366d72022","Versions":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - SAS Storage Disk"},{"Lang":"ja","Value":"ファームウェア - SASストレージ ディスク"},{"Lang":"cn","Value":"固件 - SAS 存储磁盘"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"Lang":"ja","Value":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp; HPD1<br /><strong>Firmware Dependency:</strong><br />&nbsp; &nbsp; &nbsp; None</p><p><strong>Enhancements/New Features:</strong></p><ul><li>Added support for ESXi 9.0.</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul><p><strong>Known Issues:<br />&nbsp; &nbsp; &nbsp; </strong>None</p>"}],"Files":[{"Bytes":"18906761","DateModified":"2025-03-26T12:41:39","FileList":["/CP066510_BUILD_1.data","/CP066510.vmexe64","/CP066510.vmfile","/CP066510_VMw.zip","/CP066510.xml","/payload.json","/CP066510_VMw.zip/index.xml","/CP066510_VMw.zip/vendor-index.xml","/CP066510_VMw.zip/metadata.zip","/CP066510_VMw.zip/vib20/CP066510/HPE_bootbank_CP066510_HPD2.1-8.0.0.20613240.vib","/CP066510_VMw.zip/metadata.zip/vendor-index.xml","/CP066510_VMw.zip/metadata.zip/vmware.xml","/CP066510_VMw.zip/metadata.zip/vibs/CP066510--8148657513295225398.xml","/CP066510_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066510_HPD2.1-8.0.0.20613240.xml"],"MD5Sum":"23148a8c6fe80c4089d24ad425f10abd","Name":"CP066510.zip","Release":"2025-03-26T12:40:48","Revision":"B","SHA1Sum":"dcfdcd020a1469392d9a5af276019d844b2b9fc7","SHA256Sum":"e39f8986131a13979bc72f846b18a7a717eef64854059481c3cebca98315cdc1","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"2","Version":"HPD2","VibList":[{"Name":"CP066510","Version":"HPD2.1-8.0.0.20613240"}]}],"Installation":{"Command":"CP040573.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":120,"RebootDetails":[{"Lang":"en","Value":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"Environment Dependent"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?softwareId=MTX_360731071b404454b454390208&amp;language=en_US\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://support.hpe.com/docs/display/public/a00sppdocen_US/spp/#/index.html\" id=\"menurh72\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"https://support.hpe.com/docs/display/public/a00sppdocen_us/spp/#/index.html\">HPE Service Pack for ProLiant (SPP) Home Page</a></p><p>&nbsp;</p><p><strong>To update firmware from VMware ESXi 8.0/9.0 operating system on target server:</strong></p><ul><li>Login as root. (Must be root user in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li></ul><p>&lt;full path&gt; is the absolute temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p><u>To remove VIB file:</u></p><ul><li>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"Lang":"ja","Value":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"6000"},"SupportedDevices":[{"Id":"MO000800JXBEV","TargetGUID":"4d2340a5-304f-3030-3830-304a58424556","Type":"sas"},{"Id":"MO001600JXBFP","TargetGUID":"4d2340a5-304f-3130-3630-304a58424650","Type":"sas"},{"Id":"MO003200JXBFQ","TargetGUID":"4d2340a5-304f-3330-3230-304a58424651","Type":"sas"},{"Id":"MO006400JXBFR","TargetGUID":"4d2340a5-304f-3630-3430-304a58424652","Type":"sas"},{"Id":"MO000960JXBFA","TargetGUID":"4d2340a5-304f-3030-3936-304a58424641","Type":"sas"},{"Id":"MO001920JXBFT","TargetGUID":"4d2340a5-304f-3130-3932-304a58424654","Type":"sas"},{"Id":"MO003840JXBFU","TargetGUID":"4d2340a5-304f-3330-3834-304a58424655","Type":"sas"},{"Id":"MO007680JXBGA","TargetGUID":"4d2340a5-304f-3730-3638-304a58424741","Type":"sas"},{"Id":"MO015360JXBFV","TargetGUID":"4d2340a5-304f-3531-3336-304a58424656","Type":"sas"},{"Id":"EO000400JXBEU","TargetGUID":"452340a5-304f-3030-3430-304a58424555","Type":"sas"},{"Id":"EO000800JXBFL","TargetGUID":"452340a5-304f-3030-3830-304a5842464c","Type":"sas"},{"Id":"EO001600JXBFN","TargetGUID":"452340a5-304f-3130-3630-304a5842464e","Type":"sas"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-04-25T20:50:16","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>POHが6.5年を超えた後に発生する可能性のあるドライブハングの問題を修正しました。ご不便をおかけしないためにも、できるだけ早くFWをアップデートすることをお勧めします。</li><li>詳しくは、CBが次のURLで公開されています。https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fixes the potential drive hang issue after POH exceed 6.5 years. We suggest customers to update the FW as soon as possible to prevent inconvenience.</li><li>For more information, CB is published at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=a00142174en_us</li></ul>","Lang":"cn"}],"Version":"HPD2"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for ESXi 9.0.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"HPD2"}],"SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"4d4eeb5fca8642ac80b8d8ba61ff0ffb"}]},{"ProductId":"02e2779ea258441c8ba6426a8772f536","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"Lang":"ja","Value":"ドライバー - ストレージ (FCおよびFCoE)"},{"Lang":"cn","Value":"驱动程序-存储光纤通道和以太网光纤通道"}],"Description":[{"Lang":"en","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"Lang":"ja","Value":"このRPMは、HPE Storageファイバーチャネルを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"},{"Lang":"cn","Value":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"767879","DateModified":"2025-05-24T09:07:30","FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"MD5Sum":"77e9e6b3fd80f1c5c4e1778fa1fa0946","Name":"kmod-elx-lpfc-14.4.473.24-1.rhel9u6.x86_64.rpm","Release":"2025-05-30T00:00:00","Revision":"","SHA1Sum":"5b113fd680090eb44c55f47c93f47bd7cf6cf1c7","SHA256Sum":"1dffffa2cd041ba68392f0069dc19faabb158003c3312900cad013c630cd069e","Size":"749KB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.473.24"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>1. システム管理者 (root) としてログインします。</p><p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p><p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />                    例：# rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p><p> </p><p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p><p> </p>"},{"Lang":"cn","Value":"<p>1.&nbsp;Login as the system administrator (root).</p><p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p><p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-14.2.520.3-1.rhel9u1.x86_64.rpm</p><p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p><p>&nbsp;</p><p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Red Hat Enterprise Linux 9 Server Update 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"},{"Lang":"ja","Value":"Red Hat Enterprise Linux 9 Server Update 6 Serverファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプター"},{"Lang":"cn","Value":"Red Hat Enterprise Linux 9 Server Update 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"F400","SubDev":"0368","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900368","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"0367","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f40015900367","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0214","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900214","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0213","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900213","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0202","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900202","Type":"pci","Ven":"10DF"},{"Dev":"E300","SubDev":"0201","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-e30015900201","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d5","Type":"pci","Ven":"10DF"},{"Dev":"F400","SubDev":"02D6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-10df-f400159002d6","Type":"pci","Ven":"10DF"}],"SupportedOperatingSystems":[{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-07-10T06:21:14","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>以下のサポートを追加しました。</p><p>Red Hat Enterprise Linux 10.0</p><p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added support for:</p><p>Red Hat Enterprise Linux 10.0</p><p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"},{"ReleaseNotes":[{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>バージョン14.4.473.24にアップデートしました</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Updated to&nbsp;version 14.4.473.24</p>","Fixes":"","Lang":"cn"}],"Version":"14.4.473.24"}],"SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"a4fac5794f124f64af63cf7178d65daa"}]}],"Prerequisites":[{"ProductId":"a225a11fa25340779e2e488c7b569a20","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2019とWindows Server 2022で動作する HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"3109688","DateModified":"2025-02-12T03:04:16","FileList":["cp065638.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"184714ba41f9a3b3be79f5c931dc1419","Name":"cp065638.exe","Release":"2025-02-12T02:56:33","Revision":"C","SHA1Sum":"ec4b7597ffa2f3b6cb00b0f95d095f09e18a842e","SHA256Sum":"e79223b834287bea90ffaae7c2b84af29cd7716d58994f75a162cdb2643755ed","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-12T02:34:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"62441dca1b454d09a3cbc8ffd52d97a6"}]},{"ProductId":"b8e6a95559f244b1942217b8d607ed1e","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107000&nbsp;with the following firmware versions:</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"7\">226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 535T Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td></tr><tr><td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td></tr></tbody></table>"}],"Files":[{"Bytes":"7504207","DateModified":"2024-10-15T01:39:45","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063801.scexe"],"MD5Sum":"713c039afa52686e3d8c4b76e6ed0873","Name":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","Release":"2024-10-15T06:32:46","Revision":"B","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","Size":"7MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CPXXXXXX.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CPXXXXXX.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CPXXXXXX<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CPXXXXXX.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-07T05:01:48","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8526d39348f74098b531f4e3046eb634"}]},{"ProductId":"306661aaf95b4ed88dcdac14118e89e3","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM957504 100G 1P QSFP56 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E45100","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p>This software package contains NVM Image version 226.1.107.0&nbsp;with the following firmware versions:</p><p>&nbsp;</p><table border=\"1\"><thead><tr><th>NIC</th><th>Bootcode Version</th><th>NCSI Version</th><th>MBA Version</th><th>UEFI Version</th><th>RoCE Version</th></tr></thead><tbody><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.145.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">226.0.135.0<br />&nbsp;</td><td colspan=\"1\" rowspan=\"9\">&nbsp;226.0.145.0<br />&nbsp;</td></tr><tr><td>HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter</td></tr><tr><td>HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 Adapter</td></tr><tr><td>HPE Ethernet 10/25Gb 4-port SFP28 BCM57504 OCP3 Adapter</td></tr></tbody></table><p>&nbsp;</p>"}],"Files":[{"Bytes":"9441129","DateModified":"2024-10-15T01:38:24","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/CP063802.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412A4121HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957412N4120HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414A4142HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957414N4140HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416A4162HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957416N4160HC.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504A504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/nic_fw/BCM957504N504H.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-bcm-nxe-226.1.107.0-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063802.scexe"],"MD5Sum":"eb488edbe17aa60f15122d5fac476d52","Name":"firmware-nic-is-bcm-nxe-226.1.107.0-2.1.x86_64.rpm","Release":"2024-10-15T06:32:07","Revision":"B","SHA1Sum":"d747df79fc9050fa5f002334b73a4d21cdcd4358","SHA256Sum":"5d0c0f9a58e5f558b7c8ee141d29d306f8396352c5fae26b9f4f74ffc6c40f62","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599","a6b1a447-382a-5a4f-14E4-175114E45100"],"TypeOfChange":"1","Version":"226.1.107.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p><ul><li>Install this NIC firmware rpm with the following command:&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp;</em></li></ul><p>This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />The CP056670.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP062142.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p><ul><li>To install the firmware, execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li><em>./</em>CP062142<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li><li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li></ul></li><br /><li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li></ul><p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p><ul><li>Extract the contents of the rpm with the following command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li></ul><p>This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p><ul><li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li></ul><p><strong><em>Additional Information:</em></strong></p><ul><li>The results of the firmware upgrade are saved&nbsp;in CP062142.log at &quot;/var/cpq/.&quot;</li><li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"},{"Dev":"1751","SubDev":"5100","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e45100","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-07T05:02:52","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U70","Model":"HPE ProLiant DL380a Gen12"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL320 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"0fe8c4c618054fe0bf5f8d2fd314f3f5"}]},{"ProductId":"8624b0ddbb9d42cbac863b6eec3917ae","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR216i-p Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR216i-p Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR216i-pオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR216i-p Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070258","DateModified":"2025-03-07T06:01:26","FileList":["/CP066015_BUILD_6.data","/CP066015.vmexe64","/CP066015.vmfile","/CP066015_VMw.zip","/CP066015.xml","/payload.json","/CP066015_VMw.zip/index.xml","/CP066015_VMw.zip/vendor-index.xml","/CP066015_VMw.zip/metadata.zip","/CP066015_VMw.zip/vib20/CP066015/HPE_bootbank_CP066015_52.26.3.5487.6-8.0.0.20613240.vib","/CP066015_VMw.zip/metadata.zip/vendor-index.xml","/CP066015_VMw.zip/metadata.zip/vmware.xml","/CP066015_VMw.zip/metadata.zip/vibs/CP066015--5512224417329655375.xml","/CP066015_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066015_52.26.3.5487.6-8.0.0.20613240.xml"],"MD5Sum":"64c7730a36b6f86d1b58daf0396269f7","Name":"CP066015.zip","Release":"2025-03-07T06:00:56","Revision":"B","SHA1Sum":"7ee7e7a2734686ac1937365506592ad179540555","SHA256Sum":"fdf2bdd835a62c1ed62657ed3f95a59502fa5bfe8c0b82a3dd28f2e509869435","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066015","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP066015.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:32","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"5839c976f25e48398417f7338f355dfe"}]},{"ProductId":"8384f9a8878649da8d668b07fb30c48e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"Lang":"ja","Value":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。<br /> </p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"17863296","DateModified":"2024-04-12T17:59:50","FileList":["cp060178.xml","cpqsetup.exe","ilo5_148.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"MD5Sum":"f1605545cf72d758a82e9d74b734e8b0","Name":"cp060178.exe","Release":"2024-04-12T17:57:42","Revision":"b","SHA1Sum":"78a26248d99a2128bd9918ac076b06f2fda26638","SHA256Sum":"0ae2a089157006d41251b27fc4a5a10de2300f6cc4608e5eb366d141423ac1ce","Size":"17MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"0","Version":"1.48"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Install the firmware using one of these options:</strong></p><ul><li>Run the Component on the host to be updated.<br />The component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />&nbsp;</li><li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:<ul><li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li><li>Use the HPE Lights-Out Configuration Utility, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li><li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li><li>Use the Directory Migration Utility, contained in the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li></ul></li></ul>"},{"Lang":"ja","Value":"<p><strong>以下のいずれかのオプションを使用してファームウェアをインストールしてください。</strong></p><ul><li>アップデートするホスト上のコンポーネントを実行します。<br />このコンポーネントは、iLO 5ファームウェアをアップデートし、iLO 5プロセッサーをリセットします。<br /> </li><li>コンポーネントからファームウェアを抽出します。  これにより、iLO5_yyy.bin（yyyはファームウェアバージョン）がターゲットディレクトリにコピーされます。  以下のオプションがあります。<ul><li>iLO 5にログインし、ファームウェアのアップデートページに移動して、そこからファームウェアをアップデートします。</li><li>ネットワーク経由でiLO 5をアップデートするには、HPE Lights-Out構成ユーティリティおよびRIBCL/XMLスクリプトを使用します。</li><li>サポートされているホストOSからiLO 5をアップデートするには、HPE Online Lights-Out構成ユーティリティ、HPONCFG、およびRIBCL/XMLスクリプトを使用します。</li><li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>に含まれているDirectory Migrationユーティリティを使用します。このWindowsユーティリティでは、Lights-Outプロセッサーのネットワーク検出、インポート/エクスポート機能、およびバルクファームウェアアップデートをサポートしており、ディレクトリの移行は不要です。</li></ul></li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"1","Name":"Microsoft Windows 7 (64-bit) - All Editions","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows 8.1 (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"Essentials","Major":"6","Minor":"2","Name":"Microsoft Windows Server 2012 Essentials","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"3","Name":"Microsoft Windows Server 2012 R2","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Microsoft Windows Vista (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Edition":"ent","Major":"6","Minor":"0","Name":"Microsoft Windows Vista Enterprise (64-bit)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"5","Minor":"1","Name":"Microsoft Windows XP 64-Bit Edition","Platform":"NT64","Sr":"OEM"},{"Major":"5","Minor":"2","Name":"Microsoft Windows XP Professional x64 Edition","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-03-13T11:20:10","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>iLO 5の旧バージョンのiLO 5でサポートしているすべてのDCiオプションに対して set server info コマンドを実装し、iLO 5のアップデート中にNICの設定をリセットする可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"en"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"ja"},{"Enhancements":"<p>Initial Build</p>","Fixes":"<p>Initial Build</p>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"101e95ab6e8343cc8f261f221b7694ad"}]},{"ProductId":"02754226ca24415fbdc877dfe47af242","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"8996959","DateModified":"2025-05-14T05:55:01","FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/CP066640.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066640.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066640.scexe"],"MD5Sum":"21e844347a76f963990b2262c8276e0a","Name":"firmware-smartarray-f7c07bdbbd-5.61-7.1.x86_64.rpm","Release":"2025-05-14T10:37:51","Revision":"G","SHA1Sum":"023b537c9a6c3b305209eab923c4d2df061b9005","SHA256Sum":"8b8d57d06ac15e0403b8305d25f2407d556b69b4cb45956eb10a4982d2555973","Size":"8MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"Installation":{"Command":"CP066640.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -Uvh --noscripts --oldpackage --replacefiles --replacepkgs<em>&nbsp;&lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<ul><li>./ CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul style=\"list-style-type:square; margin-left:40px\"><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T02:17:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added RHEL10 support</li></ul>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"20776780239f4f77a758d2a58e42959d"}]},{"ProductId":"f888ab7160bf41c5a9a5c8dd421e9e88","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>"}],"Files":[{"Bytes":"2175045","DateModified":"2024-10-15T21:36:43","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw/ql_hp_ah_mbi_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061237.scexe"],"MD5Sum":"73ba45b19522e271adb408a7edcb2ebb","Name":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","Release":"2024-10-16T02:29:29","Revision":"C","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059997.txt file.The results of the firmware upgrade are saved&nbsp;in CP059997.log at &quot;/var/cpq/.&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li><li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-06-20T06:35:39","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4f7626fc8ae84aa7aa653c82a10b96e2"}]},{"ProductId":"149ff2208f3a4a13b7c145a5ab625b8a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.0.14.1063"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r&nbsp;NS204i-u, NS204i-d Gen11</p><p><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,&nbsp;NS204i-u, NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r&nbsp;NS204i-u, NS204i-d Gen11</p><p><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,&nbsp;NS204i-u, NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r&nbsp;NS204i-u, NS204i-d Gen11</p><p><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,&nbsp;NS204i-u, NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp;Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1731192","DateModified":"2025-01-17T04:13:17","FileList":["cp065147.xml","cpqsetup.exe","HPE_NS204i_Gen10P_1063.bin","mnv_cli.exe","payload.json","setup.dll"],"MD5Sum":"8dc3b4d54440435c1ce5bd87c92ea9df","Name":"cp065147.exe","Release":"2025-01-17T04:11:05","Revision":"E","SHA1Sum":"4f6a556cb9f6ca69342f8731364ccbfcb7713e2f","SHA256Sum":"71864a643becff838c91db0f784c754840464a950a52d92497c60bf9768f2479","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.0.14.1063"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントを一時ディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for Windows - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"Online Firmware Flash for Windows - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"cn","Value":"Online Firmware Flash for Windows - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0310","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-16T06:45:02","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"},{"ReleaseNotes":[{"Enhancements":"<p>Support OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"}],"SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030F1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03101590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"41be0bc45f3649e484ee720a7b1add55"}]},{"ProductId":"2dc80c4ae4b943faadb938f8fc2b61d5","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HPE Smart Update Managerと一緒に使用することができます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />Select your lights-out product, then support &amp; documents, then manuals.<br />&nbsp;</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます:<br /><br /><a href=\"http://www.hp.com/go/ilo\">http://www.hpe.com/go/ilo</a><br /><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。<br /> </p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"33589045","DateModified":"2024-04-12T18:09:59","FileList":["ilo5_148.bin","ilo5_148.xml","payload.json","readme.txt"],"MD5Sum":"de8ae806c0a656958c290dae02db2314","Name":"ilo5_148.fwpkg","Release":"2024-04-12T18:05:45","Revision":"b","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","Size":"32MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"0","Version":"1.48"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p><p>localhost OS example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p><p>remote example:<br /><strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p><p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p><p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p><ul><li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li><li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li></ul><p>Update the firmware and software&nbsp;in the usual manner.</p>"},{"Lang":"ja","Value":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>を参照してください。</p><p>ローカルホストOSの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p><p>リモートの例:<br /><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p><p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p><p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p><ul><li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li><li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li></ul><p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュファームウェアパッケージ - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"70000"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"},{"Id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","TargetGUID":"","Type":"other"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"7","Name":"VMware vSphere 6.7","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"5","Name":"VMware vSphere 6.5","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"VMware vSphere 6.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"0","Minor":"0","Name":"Cross Operating System","Platform":"oi","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-03-13T11:19:53","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>iLO 5の旧バージョンのiLO 5でサポートしているすべてのDCiオプションに対して set server info コマンドを実装し、iLO 5のアップデート中にNICの設定をリセットする可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Implemented the set server info command for all the DCi supporting options in previous versions of iLO 5 which may reset NIC settings during iLO 5 update.</li></ul>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"VersionId":"f0bb94c6dff64cb39c8fb14c2dedf4c0"}]},{"ProductId":"151db6b708e24a74b7dabf5cd99dd77a","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"11818952","DateModified":"2025-02-12T02:50:45","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp065637.xml","cpqsetup.exe","FW/","FW/BCM957412A4121HC.pkg","FW/BCM957412N4120HC.pkg","FW/BCM957414A4142HC.pkg","FW/BCM957414N4140HC.pkg","FW/BCM957416A4162HC.pkg","FW/BCM957416N4160HC.pkg","FW/BCM957504A504H.pkg","FW/BCM957504N504H.pkg","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"6f16ccbb96ee1af1b6a7ecc42d0bf16d","Name":"cp065637.exe","Release":"2025-02-12T02:42:18","Revision":"B","SHA1Sum":"d390dbb77065d41157b60f2227d4c01c46895e35","SHA256Sum":"b6c3618028db03f8bc0c188a7016095560006b77121f3ae389e5f8dde7e9f531","Size":"11MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-12T02:34:38","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"4e3f94692c2f46cfacca71ae333741a7"}]},{"ProductId":"91453337f2ed4396a7328c9e1b2d5e57","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"15655367","DateModified":"2025-03-06T07:48:55","FileList":["/CP065662_BUILD_15.data","/CP065662.vmexe64","/CP065662.vmfile","/CP065662_VMw.zip","/CP065662.xml","/payload.json","/CP065662_VMw.zip/index.xml","/CP065662_VMw.zip/vendor-index.xml","/CP065662_VMw.zip/metadata.zip","/CP065662_VMw.zip/vib20/CP065662/HPE_bootbank_CP065662_226.1.107000.15-8.0.0.20613240.vib","/CP065662_VMw.zip/metadata.zip/vendor-index.xml","/CP065662_VMw.zip/metadata.zip/vmware.xml","/CP065662_VMw.zip/metadata.zip/vibs/CP065662--3598151471851419397.xml","/CP065662_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065662_226.1.107000.15-8.0.0.20613240.xml"],"MD5Sum":"29eeca764f058ced7ed93692f0faede1","Name":"CP065662.zip","Release":"2025-03-06T07:47:22","Revision":"B","SHA1Sum":"748f5573c5b614f2feef29bc8ce0e7a33a2ca3b3","SHA256Sum":"5174c2c87c1eb546c4ce4d61d6a53bc00779b3ed51a79aaea34a0c90b872ada3","Size":"14MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000","VibList":[{"Name":"CP065662","Version":"226.1.107000.15-8.0.0.20613240"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:56","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"c1576ebf797a4c3e832004eaa5bd9b88"}]},{"ProductId":"5ace706167bb418f8ac30077c43e3171","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、E208i-c、P816i-a、およびP416ie-m SR Gen10"},{"Lang":"cn","Value":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"7248752","DateModified":"2025-01-17T11:31:20","FileList":["cp065146.xml","cpqsetup.exe","HPE_luxor_5.61.bin.fw","payload.json","setup.dll"],"MD5Sum":"bb28a35fb99aec883bb50032d390e2c5","Name":"cp065146.exe","Release":"2025-01-17T11:21:34","Revision":"F","SHA1Sum":"7668b16a8b78fe48addd68fd5fca9e6fa63ee6df","SHA256Sum":"dd2394856acb4ff1a05c6a355bfb88354160f229c48260d18ffef57bedf987b3","Size":"6MB","TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><ul><li>Smartコンポーネントをテンポラリディレクトリに置きます。</li><li>Smartコンポーネントをダブルクリックします。</li><li>Smartコンポーネントの指示に従います。</li><li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li></ul><p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p><ul><li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li><li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li><li>画面の指示に従います。</li></ul><p> </p>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Windows operating system on target server:</strong></p><ul><li>Place the Smart Component in a temporary directory.</li><li>Double-click on the Smart Component.</li><li>Follow the directions given by the Smart Component.</li><li>Reboot your system if you would like the update to take effect immediately.</li></ul><p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p><ul><li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li><li>Run launch_sum.bat script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul><p>&nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"},{"Lang":"ja","Value":"Windows (x64) 用オンラインROMフラッシュコンポーネント - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、P204i-c、E208i-p、E208e-p、E208i-a、E208i-c、P816i-a、およびP416ie-m SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1803 & older)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Microsoft Windows 10 (64bit, version 1809 & later)","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-02-16T06:41:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support new OS&nbsp;Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>新しいOS Microsoft Windows Server 2025のサポート。</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new OS&nbsp;Microsoft Windows Server 2025.</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<p>Support new OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support new OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new OS&nbsp;Azure Stack HCI 23H2.</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"bfc0707b926f4adf822d0b8ab970659c"}]},{"ProductId":"602ca61a8c5c4bb59d43629712dde7fb","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41593","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D814E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416A4162HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41593","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BaseT BCM57416 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957416N4160HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF14E41592","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41595","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D614E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412A4121HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41595","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16DE14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP+ BCM57412 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957412N4120HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EB14E41594","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41597","Version":"226.1.107.0"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D714E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41597","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414N4140HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41596","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE SFP28 BCM57414 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957414A4142HC.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED14E41597","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41599","Version":"226.1.107.0"},{"DeviceName":"Broadcom BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-175114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504N504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41598","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR RoCE BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180414E41599","Version":"226.1.107.0"},{"DeviceName":"HPE NPAR BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM957504A504H.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-180114E41599","Version":"226.1.107.0"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"ja","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 7.0, 8.0 and 9.0"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"19482573","DateModified":"2025-03-07T08:15:15","FileList":["/CP065663_BUILD_4.data","/CP065663.vmexe64","/CP065663.vmfile","/CP065663_VMw.zip","/CP065663.xml","/payload.json","/CP065663_VMw.zip/index.xml","/CP065663_VMw.zip/vendor-index.xml","/CP065663_VMw.zip/metadata.zip","/CP065663_VMw.zip/vib20/CP065663/HPE_bootbank_CP065663_226.1.107.0.4-1OEM.900.0.24580437.vib","/CP065663_VMw.zip/metadata.zip/vendor-index.xml","/CP065663_VMw.zip/metadata.zip/vmware.xml","/CP065663_VMw.zip/metadata.zip/vibs/CP065663-812639207484415047.xml","/CP065663_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065663_226.1.107.0.4-1OEM.900.0.24580437.xml"],"MD5Sum":"c9d981cbef91da2f5996fafe2bbbcbc2","Name":"CP065663.zip","Release":"2025-03-07T08:13:45","Revision":"B","SHA1Sum":"822aabb53f6aab1d4577df8b8aa4fdbc5b7fcf31","SHA256Sum":"e9b347f13ccc9fde802e9e3d3a49f36d1b6f96d342af7e6ce474921c6b0a760a","Size":"18MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D814E41593","a6b1a447-382a-5a4f-14E4-16D814E41592","a6b1a447-382a-5a4f-14E4-16EE14E41592","a6b1a447-382a-5a4f-14E4-16EE14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41593","a6b1a447-382a-5a4f-14E4-16EF14E41592","a6b1a447-382a-5a4f-14E4-16D614E41595","a6b1a447-382a-5a4f-14E4-16D614E41594","a6b1a447-382a-5a4f-14E4-16DE14E41595","a6b1a447-382a-5a4f-14E4-16EB14E41595","a6b1a447-382a-5a4f-14E4-16DE14E41594","a6b1a447-382a-5a4f-14E4-16EB14E41594","a6b1a447-382a-5a4f-14E4-16D714E41597","a6b1a447-382a-5a4f-14E4-16D714E41596","a6b1a447-382a-5a4f-14E4-16EC14E41597","a6b1a447-382a-5a4f-14E4-16EC14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41596","a6b1a447-382a-5a4f-14E4-16ED14E41597","a6b1a447-382a-5a4f-14E4-175114E41599","a6b1a447-382a-5a4f-14E4-175114E41598","a6b1a447-382a-5a4f-14E4-180414E41598","a6b1a447-382a-5a4f-14E4-180114E41598","a6b1a447-382a-5a4f-14E4-180414E41599","a6b1a447-382a-5a4f-14E4-180114E41599"],"TypeOfChange":"1","Version":"226.1.107.0","VibList":[{"Name":"CP065663","Version":"226.1.107.0.4-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"Lang":"cn","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"16D8","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1593","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"1592","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","Type":"pci","Ven":"14E4"},{"Dev":"16D6","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1595","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Type":"pci","Ven":"14E4"},{"Dev":"16DE","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16EB","SubDev":"1594","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1596","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"1597","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1599","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","Type":"pci","Ven":"14E4"},{"Dev":"1751","SubDev":"1598","SubVen":"14E4","TargetGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","Type":"pci","Ven":"14E4"},{"Dev":"1804","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1598","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","Type":"pci","Ven":"14e4"},{"Dev":"1804","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","Type":"pci","Ven":"14e4"},{"Dev":"1801","SubDev":"1599","SubVen":"14e4","TargetGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","Type":"pci","Ven":"14e4"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:57","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"en"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"ja"},{"Enhancements":"<ul><li>This product enhanced the device self-diagnostic matrix and MAC verification.</li><li>This product enhanced the link-speed calculation for internal variable.</li></ul>","Fixes":"<ul><li>This product addressed device lost symptom after continuously ungraceful restart on BCM57414 OCP3 adapter.</li><li>This product addressed some RDE pattern format for some LLDP properties.</li><li>This product addressed the NC-SI passthrough with BMC when device is under idle mode.</li><li>This product addressed new mechanism for loading factory default.</li></ul>","Lang":"cn"}],"Version":"226.1.107.0"}],"SWKeys":[{"Name":"IS_BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U65","Model":"HPE MicroServer Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U50","Model":"HPE ProLiant XL420 Gen10 Plus Servers"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12 (U70)"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U70","Model":"HPE ProLiant Compute DL380a Gen12"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0602e754bc4c46f5a3f50af806cd01ac"}]},{"ProductId":"4f319faf890642fc80a3d8719760c121","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"ja","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"cn","Value":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"},{"Lang":"ja","Value":"<p>同じファームウェアバージョンの（）内のそのパッケージバージョンには、同じファームウェアバイナリイメージが含まれます。ユーザーは、同じファームウェアバージョンを再フラッシュする必要はありません。</p>"},{"Lang":"cn","Value":"<p>That package versions within () for the same firmware version include the same firmware binary image. Users don&rsquo;t need to reflash the same firmware version.</p>"}],"Files":[{"Bytes":"24514576","DateModified":"2025-03-07T06:30:41","FileList":["/CP064739_BUILD_15.data","/CP064739.vmexe64","/CP064739.vmfile","/CP064739_VMw.zip","/CP064739.xml","/payload.json","/CP064739_VMw.zip/index.xml","/CP064739_VMw.zip/vendor-index.xml","/CP064739_VMw.zip/metadata.zip","/CP064739_VMw.zip/vib20/CP064739/HPE_bootbank_CP064739_5.61.15-8.0.0.20613240.vib","/CP064739_VMw.zip/metadata.zip/vendor-index.xml","/CP064739_VMw.zip/metadata.zip/vmware.xml","/CP064739_VMw.zip/metadata.zip/vibs/CP064739-7636149840308960091.xml","/CP064739_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064739_5.61.15-8.0.0.20613240.xml"],"MD5Sum":"e0d18832300f902548c6e0f6655f960e","Name":"CP064739.zip","Release":"2025-03-07T06:20:29","Revision":"E","SHA1Sum":"d90b303a0a1313afb9128545c7290d26ca7b0db3","SHA256Sum":"9b608c26c3f5f8b882f53a813593db78d418ac45f4a6b82c03dd316f8a43276d","Size":"23MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654"],"TypeOfChange":"1","Version":"5.61","VibList":[{"Name":"CP064739","Version":"5.61.15-8.0.0.20613240"}]}],"Installation":{"Command":"CP064739.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPXXXXXX.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"ja","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"},{"Lang":"cn","Value":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"028F","SubDev":"0700","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0601","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0602","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0603","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0600","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1101","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"1100","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0651","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0654","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0652","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","Type":"pci","Ven":"9005"},{"Dev":"028F","SubDev":"0650","SubVen":"103C","TargetGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","Type":"pci","Ven":"9005"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-11T03:37:47","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support Gen10, Gen10 Plus and Gen11 servers</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Gen10、Gen10 Plus、およびGen11サーバーをサポートします</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support Gen10, Gen10 Plus and Gen11 servers</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"5.61"}],"SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U57","Model":"HPE Alletra Storage Server 4140"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"26f599a3999d401ebc13206d38bc9081"}]},{"ProductId":"521144c543434ae9b4777bf076b798c5","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.0.14.1063"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"このx64 Smartコンポーネントは、HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、NS204i-t、NS204i-r、NS204i-u、およびNS204i-d Gen11のファームウェアを提供します"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,NS204i-u and NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</p><p><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and&nbsp;NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>提供名:</strong><br />オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、NS204i-t、NS204i-r、NS204i-u、およびNS204i-d Gen11</p><p><br /><strong>リリースバージョンおよび/または日付:</strong><br />     1.0.14.1063<br /><br /><strong>最新の推奨またはクリティカルバージョン：</strong><br />     1.0.14.1063<br /><br /><strong>前のファームウェアバージョン：</strong><br />     なし</p><p><strong>ファームウェアの依存関係：</strong><br />     なし<br /><br /><strong>機能強化/新しい機能：</strong></p><ul><li>HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、NS204i-t、NS204i-r、NS204i-u、およびNS204i-d Gen11のサポート</li></ul><p><strong>修正された問題:</strong></p><ul><li>     予期しないFWアップグレードエラーを引き起こすRDEディクショナリの破損に関するv1055の既知の問題を修正しました。これはv1063で解決されました。</li></ul><p><strong>既知の問題点:</strong><br />     なし</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</p><p><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and&nbsp;NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; &nbsp; &nbsp;Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"1460980","DateModified":"2025-05-14T06:33:42","FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/CP066644.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/HPE_NS204i_Gen10P_1063.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1063-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP066644.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP066644.scexe"],"MD5Sum":"a70c35bc4c9eb5b19767ed89a290f8f9","Name":"firmware-9041739931-1.0.14.1063-5.1.x86_64.rpm","Release":"2025-05-14T11:22:47","Revision":"E","SHA1Sum":"f99df8fa5d201a865b32fd8226b37ef441834237","SHA256Sum":"367ee4a345a5d6b1ebd6471ec90fc016a148a91cb8394e25898bcc34a4838204","Size":"1MB","TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.0.14.1063"}],"Installation":{"Command":"CP063972.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"},{"Lang":"ja","Value":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p><p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p><ul><li>コマンドを使用して、ファームウェアrpmをインストールします：  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li><li>CPXXXXXX.scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-9041739931dr-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<ul><li>./CPXXXXXX.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li><li><em>./setup</em>（'/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*'で実行）</li></ul></li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li><li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子の付いていないrpmファイル名）を実行します。</li></ul><p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p><ul><li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li><li>'usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*'の場所に移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-9041739931dr-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li><li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li></ul><p><strong><em>追加情報：</em></strong></p><p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p><p> </p><p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br /><br /><strong>オフライン：</strong></p><ul><li><a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li><li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li><li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li><li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li></ul><p><strong>オンライン：</strong></p><ul><li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li><li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li><li>ISOのルートにある launch_sum.sh スクリプトを実行します。</li><li>画面の指示に従います。</li></ul>"},{"Lang":"cn","Value":"<p><strong>To update firmware from Linux operating system on target server:</strong></p><p><strong><em>Updating firmware with rpm installed:</em></strong></p><ul><li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li><li>The CPXXXXXX.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li><li>To install firmware, you can execute <strong>ONE</strong> of the following commands:<ul><li>./CPXXXXXX.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li><li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location</li></ul></li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li><li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li></ul><p><strong><em>Updating firmware without installing the rpm:</em></strong></p><ul><li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li><li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-9041739931dr-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-9041739931dr-*&#39; folder is based on the version of the rpm installed in the step above</li><li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li></ul><p><strong><em>Additional Information:</em></strong></p><p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p><p>&nbsp;</p><p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br /><br /><strong>Offline:</strong></p><ul><li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li><li>Boot from the newly created Service Pack for Proliant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>Online:</strong></p><ul><li>Login as root. (You must be root in order to apply the ROM update.)</li><li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li><li>Run launch_sum.sh script which is found in the root of the ISO</li><li>Follow the instructions on the screen</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for Linux(x64) - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"オンラインファームウェアフラッシュfor Linux (x64) - HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、NS204i-t、NS204i-r、NS204i-u、およびNS204i-d Gen11"},{"Lang":"cn","Value":"Online Firmware Flash for Linux(x64) - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r,NS204i-u and NS204i-d Gen11"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"2241","SubDev":"030F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0310","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"10","Minor":"0","Name":"Red Hat Enterprise Linux 10","Platform":"Red_Hat_Enterprise_Linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-05-02T02:29:13","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>N/A</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>N/A.</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"},{"ReleaseNotes":[{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"en"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"ja"},{"Enhancements":"<ul><li>Added support for RHEL 10.</li></ul>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"}],"SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030F1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03101590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"56e50852cae74df5bc61b6f99aba40e5"}]},{"ProductId":"8aa4f1e30dfc4417885cea85b551314e","Versions":[{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":150,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Lights-Out Management"},{"Lang":"ja","Value":"ファームウェア - Lights-Outマネジメント"},{"Lang":"cn","Value":"固件 - Lights-Out Management"}],"Description":[{"Lang":"en","Value":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HP Smart Update Manager."},{"Lang":"ja","Value":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HP Smart Update Managerと一緒に使用することが出来ます。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>&nbsp;</p><p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />Select your lights-out product, then support &amp; documents, then manuals.</p><ul><li>Check the online help for additional information about how to use features.&nbsp;<br />Online help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li></ul>"},{"Lang":"ja","Value":"<p> </p><p>また、『iLO 5ユーザーガイド』および『Lights-Outスクリプティングガイド』も下記のリンクから入手できます：<br /><a href=\"http://www.hpe.com/info/ilo-docs\" rel=\"noopener noreferrer\" target=\"_blank\">http://www.hpe.com/info/ilo-docs</a><br />ご使用のLights-Out製品、サポート&ドキュメント、ドキュメントの順に選択します。</p><ul><li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />オンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li></ul>"}],"Files":[{"Bytes":"17467512","DateModified":"2024-10-24T02:11:56","FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/CP064211.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/ilo5_148.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064211.scexe"],"MD5Sum":"555d32c65e31b4b84e634de11acef16a","Name":"firmware-ilo5-1.48-3.1.x86_64.rpm","Release":"2024-10-24T07:04:16","Revision":"c","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","Size":"16MB","TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"Installation":{"Command":"sh CP0XXXXX.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":150,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>To update firmware from Linux operating system on target server:<br />&nbsp;<br />Install the RPM package<br />&gt; rpm -Uvh &lt;filename&gt;.rpm<br />&nbsp;<br />See where the files land<br />&gt; rpm -qlp &lt;filename&gt;.rpm<br />&nbsp;<br />Change to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p><p>Supplemental updates for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p><p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.<br />Place the desired components to be updated in the directory, \\packages on the USB key.<br />Update the firmware and software in the usual manner.</p>"},{"Lang":"ja","Value":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br /> <br />RPMパッケージをインストールします。<br />>rpm -Uvh <filename>.rpm<br /> <br />ファイルの保存場所を確認してください。<br />>rpm -qlp <filename>.rpm<br /> <br />前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。</p><p>サポートされるProLiantサーバーおよびオプションのためのサプリメンタルアップデートは、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p><p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。<br />アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。<br />通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"Lang":"ja","Value":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"5120"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86)","Platform":"red_hat_enterprise_linux_x86","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Server (x86-64)","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Workstation (x86)","Platform":"red_hat_enterprise_linux_client_x86","Sr":"OEM"},{"Major":"6","Minor":"0","Name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","Platform":"red_hat_enterprise_linux_client_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"11","Minor":"0","Name":"SUSE LINUX Enterprise Server 11 (x86)","Platform":"suse_linux_enterprise_server_x86","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-11-23T12:30:19","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"en"},{"Enhancements":"<p>なし</p>","Fixes":"<p>OS FIPSモードでのインストールを有効にします。</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Enabling installation in OS FIPS mode.</p>","Lang":"cn"}],"Version":"1.48"},{"ReleaseNotes":[{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"en"},{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"ja"},{"Enhancements":"<p>None</p>","Fixes":"<p>Built with new&nbsp;RPM signing key</p>","Lang":"cn"}],"Version":"1.48"}],"SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"I41","Model":"HPE ProLiant BL460c Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"","Model":"HPE ProLiant ML150 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U38","Model":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"Family":"U38","Model":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A45","Model":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"Family":"U51","Model":"HPE ProLiant XL920g Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U47","Model":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"}],"UpgradeRequirements":"Recommended"},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"705315077b1e4ba986471688e76a38e4"}]},{"ProductId":"03731a36570c4baca7e553d9af4e7172","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR416i-a Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR416i-a&nbsp;Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR416i-aオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR416i-a&nbsp;Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070512","DateModified":"2025-03-07T08:11:23","FileList":["/CP066016_BUILD_8.data","/CP066016.vmexe64","/CP066016.vmfile","/CP066016_VMw.zip","/CP066016.xml","/payload.json","/CP066016_VMw.zip/index.xml","/CP066016_VMw.zip/vendor-index.xml","/CP066016_VMw.zip/metadata.zip","/CP066016_VMw.zip/vib20/CP066016/HPE_bootbank_CP066016_52.26.3.5487.8-8.0.0.20613240.vib","/CP066016_VMw.zip/metadata.zip/vendor-index.xml","/CP066016_VMw.zip/metadata.zip/vmware.xml","/CP066016_VMw.zip/metadata.zip/vibs/CP066016--1627405003484883866.xml","/CP066016_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066016_52.26.3.5487.8-8.0.0.20613240.xml"],"MD5Sum":"9d5ef52f03725b0dcd8a7b78f047bf95","Name":"CP066016.zip","Release":"2025-03-07T08:10:52","Revision":"B","SHA1Sum":"a7366d7e21e6cb4417cd41c36339f66e5b471dc2","SHA256Sum":"5614bc78ccf8c4efae90e02be2207b6bbadc33cd6d5c7934999fbe8d2ab9a241","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066016","Version":"52.26.3.5487.8-8.0.0.20613240"}]}],"Installation":{"Command":"CP066016.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p><p>&nbsp;</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:34","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"6b2e85bef481441482ee2a1e938fdc49"}]},{"ProductId":"f0c6d80ec7ba4100b11a93d13a983f16","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.0.14.1063"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_Gen10P_1063.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.0.14.1063"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11"},{"Lang":"cn","Value":"The x64 Smart Component provides firmware for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"ja","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"},{"Lang":"cn","Value":"<p><strong>Deliverable Name:</strong><br />Online ROM Flash Component for ESXi&nbsp;- HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11<br /><br /><strong>Release Version and/or Date:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Last Recommended or Critical Version:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1063<br /><br /><strong>Previous Version of Firmware:</strong><br />&nbsp; &nbsp; &nbsp;None</p><p><strong>Firmware Dependency:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None<br /><br /><strong>Enhancements/New Features:</strong></p><ul><li>Support for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r ,NS204i-u and NS204i-d Gen11</li></ul><p><strong>Problems Fixed:</strong></p><ul><li>&nbsp; Fixed&nbsp;known issue on v1055 regarding RDE dictionary broken which will cause unexpected FW upgrading error, which was solved in v1063</li></ul><p><strong>Known Issues:</strong><br />&nbsp;&nbsp;&nbsp;&nbsp; None</p>"}],"Files":[{"Bytes":"2460556","DateModified":"2025-03-07T05:26:57","FileList":["/CP064740_BUILD_19.data","/CP064740.vmexe","/CP064740.vmexe64","/CP064740.vmfile","/CP064740_VMw.zip","/CP064740.xml","/payload.json","/CP064740_VMw.zip/index.xml","/CP064740_VMw.zip/vendor-index.xml","/CP064740_VMw.zip/metadata.zip","/CP064740_VMw.zip/vib20/CP064740/HPE_bootbank_CP064740_1.0.14.1063.19-8.0.0.20613240.vib","/CP064740_VMw.zip/metadata.zip/vendor-index.xml","/CP064740_VMw.zip/metadata.zip/vmware.xml","/CP064740_VMw.zip/metadata.zip/vibs/CP064740--4711026067273918711.xml","/CP064740_VMw.zip/metadata.zip/bulletins/Smart-Component-CP064740_1.0.14.1063.19-8.0.0.20613240.xml"],"MD5Sum":"7e3d0a1826ff02c5f68d43e7bb1ff089","Name":"CP064740.zip","Release":"2025-03-07T05:26:23","Revision":"C","SHA1Sum":"d6b2db60553f0bc0b344072d4832bc0ba10c1a78","SHA256Sum":"acba346dab99883b5346a649d300c90e337ac1ac54303fdeeb38d24947bce54a","Size":"2MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.0.14.1063","VibList":[{"Name":"CP064740","Version":"1.0.14.1063.19-8.0.0.20613240"}]}],"Installation":{"Command":"CP064740.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"ja","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"},{"Lang":"cn","Value":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br /><br />&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p><ul><li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;softwareId=MTX_360731071b404454b454390208\">USB Key Utility for Windows</a>.</li><li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li><li>Boot from the newly created Service Pack for ProLiant USB key.</li><li>Follow Smart Update Manager steps to complete firmware update.</li></ul><p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p><ul><li>Download the appropriate SPP.</li><li>Add the component to the SPP.</li><li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li><li>Run SUM.</li><li>Add the ESXi host to be updated as a remote target/node.</li><li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li><li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li><li>Follow Smart Update Manager Steps and complete the firmware update.</li></ul><p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />&nbsp;</p><p><strong>Additional information to execute VIB file.</strong></p><p><u>Commands required to execute VIB file on ESXi 8.0/9.0</u></p><ul style=\"list-style-type:square\"><li>Enable Tech Support Mode on the ESXi host.</li><li>Login as root. (You must be root in order to apply the update.)</li><li>Place the Smart Component zip file in a temporary directory.</li><li>Unzip the file CPxxxxxx.zip</li><li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li><li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li><li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li></ul><p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Online Firmware Flash for ESXi - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"ja","Value":"Online Firmware Flash for ESXi - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"},{"Lang":"cn","Value":"Online Firmware Flash for ESXi - HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r, NS204i-u and NS204i-d Gen11"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"2241","SubDev":"02F6","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0310","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"030E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0379","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","Type":"pci","Ven":"1B4B"},{"Dev":"2241","SubDev":"0380","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","Type":"pci","Ven":"1B4B"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-01-11T03:44:18","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>Support new server.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>新しいサーバーのサポート</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support new server.</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"},{"ReleaseNotes":[{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Support ESXi9.0.</p>","Fixes":"","Lang":"cn"}],"Version":"1.0.14.1063"}],"SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030F1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03101590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4510 System"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U54","Model":"HPE ProLiant DL380 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant DL360 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"H11","Model":"HPE Compute Edge Server e930t"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"3e1d5f93d6174802bc42253cb183ee7d"}]},{"ProductId":"799046a4ae3d4743be83cc950a1f1f68","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"28163179","DateModified":"2025-03-07T08:15:24","FileList":["/CP065660_BUILD_2.data","/CP065660.vmexe64","/CP065660.vmfile","/CP065660_VMw.zip","/CP065660.xml","/payload.json","/CP065660_VMw.zip/index.xml","/CP065660_VMw.zip/vendor-index.xml","/CP065660_VMw.zip/metadata.zip","/CP065660_VMw.zip/vib20/CP065660/HPE_bootbank_CP065660_8.55.12.2-1OEM.900.0.24580437.vib","/CP065660_VMw.zip/metadata.zip/vendor-index.xml","/CP065660_VMw.zip/metadata.zip/vmware.xml","/CP065660_VMw.zip/metadata.zip/vibs/CP065660-4554546092090114858.xml","/CP065660_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065660_8.55.12.2-1OEM.900.0.24580437.xml"],"MD5Sum":"002e144815c390a33394cc5ab328dedd","Name":"CP065660.zip","Release":"2025-03-07T08:13:58","Revision":"B","SHA1Sum":"e89488a1cc4103e463075a20017f993a1536462b","SHA256Sum":"463c4edece7068202675f282a957c65916de0bf397996b0dbfbabd515b2c0330","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP065660","Version":"8.55.12.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"021D","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021d","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021F","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021f","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0220","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-807015900220","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"02BD","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-8070159002bd","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021A","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021a","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"021B","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1077-80701590021b","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-13T08:40:54","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"en"},{"Enhancements":"<p>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</p>","Fixes":"<p>この製品は、iPXEブートを試行しているときのスイッチのPause Flood状態に対処します。</p>","Lang":"ja"},{"Enhancements":"<p>This product contains support PLDM firmware upgrade base improvements.</p>","Fixes":"<p>This product addresses a pause flood condition on switch when attempting iPXE boot.</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"P89","Model":"HPE ProLiant DL380 Gen9 Server"},{"Family":"P89","Model":"HPE ProLiant DL360 Gen9 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U40","Model":"HPE Apollo 4530 Gen10"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"02020001","Model":"HPE Superdome Flex 280"},{"Family":"03020101","Model":"HPE Superdome Flex Server"},{"Family":"03020102","Model":"HPE Superdome Flex 2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"16812b1e5cfb47c5a13a2e8e320d8624"}]},{"ProductId":"39f751214cc74d66b0930165bf7cce77","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"Lang":"ja","Value":"このパッケージには、Linux x86_64プラットフォームで動作するMarvell FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[{"Lang":"en","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"ja","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"},{"Lang":"cn","Value":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>"}],"Files":[{"Bytes":"2219909","DateModified":"2024-10-15T21:35:02","FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw/ql_ah_mbi_open_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061236.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061236.scexe"],"MD5Sum":"2b0e832e4cbf1b2a5419e09c10fa968e","Name":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","Release":"2024-10-16T02:28:54","Revision":"C","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","Size":"2MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"ja","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"},{"Lang":"cn","Value":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p><ul><li>Install the firmware rpm package:<br /><em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li><li>Check where the files are extracted:<br /><em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li><li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li></ul><p>&nbsp;</p><p><strong><em>Additional Information:</em></strong></p><ul><li>Further information&nbsp;is available in CP059998.txt file.The results of the firmware upgrade are saved&nbsp;in CP059998.log at &quot;/var/cpq/&quot;</li><li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li><li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li></ul>"}],"ManufacturerName":[],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"},{"Lang":"cn","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2024-06-20T06:34:51","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"df0d2e84414545c18a181d95d2115f5e"}]},{"ProductId":"9b49e335f12147b9aba4f47e0e39b392","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Windows Server 2019およびWindows Server 2022で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[],"Files":[{"Bytes":"9906752","DateModified":"2025-02-12T02:49:19","FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp065636.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"006796ee912d62f14bd1a302bfc0350a","Name":"cp065636.exe","Release":"2025-02-12T02:41:06","Revision":"B","SHA1Sum":"178138042ddfd494591d944846412fb07d8778f1","SHA256Sum":"05c5ea898328e3912c2e89ee620da6e9500cba8f4b3d75fc2a71fed79b7a71d5","Size":"9MB","TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EE15900212"],"TypeOfChange":"1","Version":"226.1.107000"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティfor Windows Server x64 Edition"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"16D7","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"020E","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"0211","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D7","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C3","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Type":"pci","Ven":"14E4"},{"Dev":"16ED","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16EC","SubDev":"02C5","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"020C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Type":"pci","Ven":"14E4"},{"Dev":"16D8","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","Type":"pci","Ven":"14E4"},{"Dev":"16EF","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","Type":"pci","Ven":"14E4"},{"Dev":"16EE","SubDev":"0212","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","Type":"pci","Ven":"14E4"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-12T02:34:36","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>add&nbsp;Azure Stack HCI OS supported</p>","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"en"},{"Enhancements":"<p>add&nbsp;Azure Stack HCI OS supported</p>","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"ja"},{"Enhancements":"<p>add&nbsp;Azure Stack HCI OS supported</p>","Fixes":"<ul><li>This product addressed the NC-SI passthrough algorithm for some FRU-reading commands from platform side.</li><li>This product addressed the packet forwarding rule while receiving packet which is bigger than 9600 jumbo size.</li><li>This product addressed the link failure under FreeBSD OS after changing link speed.</li><li>This product addressed the failure of bringing up VFs of SRIOV when doing on and off switch.</li><li>This product addressed adapter not responsive when work under heavy loading with 128 VMs.</li><li>The product addressed status reporting&nbsp; of PLDM sensor monitoring with BMC.</li><li>This product addressed the link-flap after link down or warm boot.</li></ul>","Lang":"cn"}],"Version":"226.1.107000"}],"SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL388 Gen10 Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U36","Model":"HPE ProLiant DL120 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U39","Model":"HPE ProLiant XL420 Gen10 Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"O43","Model":"HPE ProLiant MicroServer Gen10 Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"U26","Model":"HPE ProLiant Thin Micro TM200 Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"8b39a032070d49fa910c3b78c81cdec1"}]},{"ProductId":"dedfd9d7098c498bab2315e3fb7e4b66","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR216i-a Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR216i-a&nbsp;Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR216i-aオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR216i-a&nbsp;Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070385","DateModified":"2025-03-07T07:05:19","FileList":["/CP066014_BUILD_13.data","/CP066014.vmexe64","/CP066014.vmfile","/CP066014_VMw.zip","/CP066014.xml","/payload.json","/CP066014_VMw.zip/index.xml","/CP066014_VMw.zip/vendor-index.xml","/CP066014_VMw.zip/metadata.zip","/CP066014_VMw.zip/vib20/CP066014/HPE_bootbank_CP066014_52.26.3.5487.13-8.0.0.20613240.vib","/CP066014_VMw.zip/metadata.zip/vendor-index.xml","/CP066014_VMw.zip/metadata.zip/vmware.xml","/CP066014_VMw.zip/metadata.zip/vibs/CP066014-3880614203087116731.xml","/CP066014_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066014_52.26.3.5487.13-8.0.0.20613240.xml"],"MD5Sum":"058a31386050f3a6e14429de3ea1372e","Name":"CP066014.zip","Release":"2025-03-07T07:04:48","Revision":"B","SHA1Sum":"73b2d0551a698e2ae01e5e0eb8a8490e9aff94dc","SHA256Sum":"e76a32934d4f623f56bc95e92739897fd6b24930f5a26b582bb09796e592d707","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066014","Version":"52.26.3.5487.13-8.0.0.20613240"}]}],"Installation":{"Command":"CP066014.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"032C","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:31","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"0567d9daf4ba4f0b8a156d9768148c71"}]},{"ProductId":"b3a8e7e2c4ea466a9b404955f474449e","Versions":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Package":{"Category":[{"Lang":"en","Value":"Application - System Management"},{"Lang":"ja","Value":"アプリケーション - システム マネジメント"},{"Lang":"cn","Value":"应用程序 - 系统管理"}],"Description":[{"Lang":"en","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"cn","Value":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."},{"Lang":"ja","Value":"Integrated Smart Update Tools(iSUT)は、サーバーのローカル管理者の資格証明書を使用したiLO管理ネットワークから、ファームウェアやソフトウェアの展開を可能にするアプリケーションです。iSUTは、HPE OneView管理対象サーバーまたはiLO Amplifierパックまたはオンデマンドモードでの処理時、サービスとして実行できます。iSUTは、Smart Update Managerバージョン8.0.0以降および展開用のiLO Advanced Packライセンスを含む、Service Pack for ProLiantをベースとしたISOを必要とします。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]},{"Division":[{"Lang":"en","Value":"Lights Out"},{"Lang":"ja","Value":"Lights Out"},{"Lang":"cn","Value":"Lights Out"}]}],"Documentation":[],"Files":[{"Bytes":"7818457","DateModified":"2024-10-30T05:03:48","FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/d01fe263104c65c66707eca3d31d173f66dc7e","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"MD5Sum":"afa1ae18bde501b0f3327a62759ae1f5","Name":"sut-5.3.0-10.linux.x86_64.rpm","Release":"2024-10-30T09:59:06","Revision":"","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","Size":"7MB","TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"5.3.0.0"}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{},"PerDeviceInstallTimeSeconds":0,"RebootDetails":[{"Lang":"en","Value":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"Lang":"cn","Value":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}],"RebootRequired":"no","RebootRequirement":"No"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"ja","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"},{"Lang":"cn","Value":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"cn","Value":"Integrated Smart Update Tools for Linux x64"},{"Lang":"ja","Value":"Integrated Smart Update Tools for Linux x64"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"0"},"SupportedDevices":[{"Dev":"3307","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3307159000e4","Type":"pci","Ven":"103C"},{"Dev":"3307","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330700000000","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"00E4","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-103c-3306159000e4","Type":"pci","Ven":"103C"},{"Dev":"3306","SubDev":"0000","SubVen":"0000","TargetGUID":"a6b1a447-382a-5a4f-103C-330600000000","Type":"pci","Ven":"103C"}],"SupportedOperatingSystems":[{"Major":"12","Minor":"0","Name":"SUSE Linux Enterprise Server 12","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"15","Minor":"0","Name":"SUSE Linux Enterprise Server 15","Platform":"suse_linux_enterprise_server_x86_64","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"Red Hat Enterprise Linux 8 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"Red Hat Enterprise Linux 9 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"},{"Major":"7","Minor":"0","Name":"Red Hat Enterprise Linux 7 Server","Platform":"red_hat_enterprise_linux_x86_64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2024-10-23T12:48:49","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"5.2.0.0"},{"ReleaseNotes":[{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"en"},{"Enhancements":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Fixes":"<p>今回のリリースで解決した問題についての情報は、<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&t=All&sort=relevancy&numberOfResults=25\">iSUT Release Notes</a>を参照してください。</p>","Lang":"ja"},{"Enhancements":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Fixes":"<p>See the&nbsp;<a href=\"https://support.hpe.com/connect/s/search?language=en_US#q=integrated%20smart%20update%20tools&amp;t=All&amp;sort=relevancy&amp;numberOfResults=25\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>","Lang":"cn"}],"Version":"5.3.0.0"}],"SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"","Model":"HP Smart Update Tools (HP SUT)"},{"Family":"A55","Model":"HPE ProLiant DL385 Gen11 Server"},{"Family":"A55","Model":"HPE ProLiant DL365 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL325 Gen11 Server"},{"Family":"A56","Model":"HPE ProLiant DL345 Gen11 Server"},{"Family":"U34","Model":"HPE ProLiant DL580 Gen10 Server"},{"Family":"U34","Model":"HPE ProLiant DL560 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"A40","Model":"HPE ProLiant DL385 Gen10 Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A41","Model":"HPE ProLiant DL325 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL180 Gen10 Server"},{"Family":"U31","Model":"HPE ProLiant DL160 Gen10 Server"},{"Family":"U43","Model":"HPE ProLiant DL20 Gen10 Server"},{"Family":"U41","Model":"HPE ProLiant ML350 Gen10 Server"},{"Family":"U33","Model":"HPE ProLiant ML110 Gen10 Server"},{"Family":"U44","Model":"HPE ProLiant ML30 Gen10 Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U40","Model":"HPE ProLiant XL450 Gen10 Server"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"U45","Model":"HPE Proliant XL270d Gen10 Server"},{"Family":"U37","Model":"HPE ProLiant XL230k Gen10 Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U38","Model":"HPE ProLiant XL190r Gen10 Server"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"","Model":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"U39","Model":"HPE Apollo 4200 Gen10 Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"U64","Model":"HPE ProLiant MicroServer Gen10 Plus v2"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"I43","Model":"HPE Synergy 660 Gen10 Compute Module"},{"Family":"I44","Model":"HPE Synergy 480 Gen10 Plus Compute Module"},{"Family":"I42","Model":"HPE Synergy 480 Gen10 Compute Module"},{"Family":"I45","Model":"HPE Synergy 480 Gen11 Compute Module"},{"Family":"U65","Model":"HPE ProLiant ML30 Gen11"},{"Family":"U65","Model":"HPE ProLiant DL20 Gen11"},{"Family":"U58","Model":"HPE ProLiant DL380a Gen11"},{"Family":"U59","Model":"HPE ProLiant DL560 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant DL320 Gen11 Server"},{"Family":"U62","Model":"HPE ProLiant DL110 Gen11 Server"},{"Family":"U63","Model":"HPE ProLiant ML110 Gen11 Server"},{"Family":"U54","Model":"HPE ProLiant ML350 Gen11 Server"},{"Family":"U58","Model":"HPE Alletra Storage Server 4120"},{"Family":"U58","Model":"HPE Alletra 4110 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL320 Gen12 SP Server"},{"Family":"U71","Model":"HPE ProLiant Compute DL340 Gen12 Server"},{"Family":"U69","Model":"HPE ProLiant Compute DL340 Gen12 SP Server"}],"UpgradeRequirements":"Recommended"},"Type":"Software","UpdatableBy":["RuntimeAgent"],"VersionId":"151e85c53b0b4ca0b072e7b487d0ff4f"}]},{"ProductId":"97376eb681cc4681a46dc573b80df4a8","Versions":[{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3.5487"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Storage Controller"},{"Lang":"ja","Value":"ファームウェア - ストレージ コントローラ"},{"Lang":"cn","Value":"固件 - 存储控制器"}],"Description":[{"Lang":"en","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"ESXi Smartコンポーネントは、HPE MR416i-p Gen10 Plusトライモードコントローラー用のコントローラーファームウェアを提供します"},{"Lang":"cn","Value":"The ESXi Smart Component provides controller firmware for HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Storage"},{"Lang":"ja","Value":"ストレージ"},{"Lang":"cn","Value":"存储设备"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]}],"Documentation":[{"Lang":"en","Value":"<p>HPEMR416i-p Online FW Update with OS command option.</p>"},{"Lang":"ja","Value":"<p>OSコマンドオプションを使用したHPEMR416i-pオンラインFWアップデート。</p>"},{"Lang":"cn","Value":"<p>HPEMR416i-p Online FW Update with OS command option.</p>"}],"Files":[{"Bytes":"13070191","DateModified":"2025-03-07T07:19:13","FileList":["/CP066017_BUILD_6.data","/CP066017.vmexe64","/CP066017.vmfile","/CP066017_VMw.zip","/CP066017.xml","/payload.json","/CP066017_VMw.zip/index.xml","/CP066017_VMw.zip/vendor-index.xml","/CP066017_VMw.zip/metadata.zip","/CP066017_VMw.zip/vib20/CP066017/HPE_bootbank_CP066017_52.26.3.5487.6-8.0.0.20613240.vib","/CP066017_VMw.zip/metadata.zip/vendor-index.xml","/CP066017_VMw.zip/metadata.zip/vmware.xml","/CP066017_VMw.zip/metadata.zip/vibs/CP066017--8757306290411093994.xml","/CP066017_VMw.zip/metadata.zip/bulletins/Smart-Component-CP066017_52.26.3.5487.6-8.0.0.20613240.xml"],"MD5Sum":"fcc07bd86e54364cb595563406fd4e08","Name":"CP066017.zip","Release":"2025-03-07T07:18:36","Revision":"B","SHA1Sum":"035b5e52dc0c49364f751414b0f5a08f44808f22","SHA256Sum":"a915d75da1b381c550ef174f26c5cb5569d617fb46baf3b3f7b74330f014eb61","Size":"12MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP066017","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"Installation":{"Command":"CP066017.scexe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":300,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"ja","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"},{"Lang":"cn","Value":"<p><strong>Commands required to execute VIB file on ESXi 8.0 / 9.0</strong></p><p>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.<br />Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</p><p>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx<br />After removing the vib, user need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx<br />&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p><p>&nbsp;</p><p>The version 52.26.3-5487 will support downgrade operation.</p>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"ja","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"Lang":"cn","Value":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1500"},"SupportedDevices":[{"Dev":"10E2","SubDev":"0293","SubVen":"1590","TargetGUID":"a6b1a447-382a-5a4f-1000-10e215900293","Type":"pci","Ven":"1000"}],"SupportedOperatingSystems":[{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-26T03:33:35","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"en"},{"Enhancements":"","Fixes":"<ul><li>PLDMファームウェアアップデートが失敗する可能性がある問題を修正します。この問題は、コントローラー、バックプレーン、およびコントローラーに接続されたドライブで発生する可能性があります。</li></ul>","Lang":"ja"},{"Enhancements":"","Fixes":"<ul><li>Fix an issue that PLDM firmware update may fail. The issue may happen on controller, backplane and drive attached to controller.</li></ul>","Lang":"cn"}],"Version":"52.26.3.5487"},{"ReleaseNotes":[{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"en"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"ja"},{"Enhancements":"<p>Added ESXi9 support</p>","Fixes":"","Lang":"cn"}],"Version":"52.26.3.5487"}],"SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U30","Model":"HPE ProLiant DL380 Gen10 Server"},{"Family":"U32","Model":"HPE ProLiant DL360 Gen10 Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"SPP","Model":"HPE Service Pack for ProLiant"}],"UpgradeRequirements":"Recommended"},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"VersionId":"1b93ff065b584fa0a120fc739b088ef5"}]},{"ProductId":"cdec784418854d66b9abfcfb18b3f4ef","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2019 and Windows Server 2022."},{"Lang":"ja","Value":"このパッケージには、Microsoft Windows Server 2019とWindows Server 2022で動作するMarvell  FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"3153936","DateModified":"2025-02-12T03:03:17","FileList":["cp065639.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_ah_mbi_open_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"MD5Sum":"3a30f130cec2b8b97f2ce61625609fe4","Name":"cp065639.exe","Release":"2025-02-12T02:55:04","Revision":"C","SHA1Sum":"c61675906bf4084e55c41aad280a04e8853152be","SHA256Sum":"9807f4881fb20b4ae5baa8269b677480ce41a45700a66cc35662dcfa373c7afe","Size":"3MB","TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"Installation":{"Command":"cpqsetup.exe","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"yes"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"},{"Lang":"ja","Value":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p><p>From that drive and directory, execute the downloaded file.</p><p>&nbsp;</p><p>Click the &quot;Install&quot; button to proceed with the installation.</p><p>&nbsp;</p><p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p><p><strong><em>Additional Information:</em></strong></p><ul><li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li></ul>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"15000"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"10","MaximumBuild":"18999","MinimumBuild":"17600","Minor":"0","Name":"Microsoft Windows Server 2019","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"17599","MinimumBuild":"14393","Minor":"0","Name":"Microsoft Windows Server 2016","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MaximumBuild":"25398","MinimumBuild":"20317","Minor":"0","Name":"Microsoft Windows Server 2022","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25399","Minor":"0","Name":"Microsoft Windows Server 2025","Platform":"nt_x86-64","Sr":"OEM"},{"Major":"10","MinimumBuild":"25398","Minor":"0","Name":"Azure Stack HCI 23H2","Platform":"nt_x86-64","Sr":"OEM"}],"SupportedPlatforms":false},"ReleaseDate":"2025-03-12T02:34:40","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"VersionId":"e88a50d4a2ec41e1af083a004777ddac"}]},{"ProductId":"34e01a655b2044b49c3eed7238c1eb30","Versions":[{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Package":{"Category":[{"Lang":"en","Value":"Firmware - Network"},{"Lang":"ja","Value":"ファームウェア - ネットワーク"},{"Lang":"cn","Value":"固件 - 网络"}],"Description":[{"Lang":"en","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"Lang":"ja","Value":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するMarvell FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"},{"Lang":"cn","Value":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."}],"Divisions":[{"Division":[{"Lang":"en","Value":"Networking"},{"Lang":"ja","Value":"ネットワーク"},{"Lang":"cn","Value":"网络"}]},{"Division":[{"Lang":"en","Value":"Server"},{"Lang":"ja","Value":"サーバ"},{"Lang":"cn","Value":"服务器"}]},{"Division":[{"Lang":"en","Value":"ServerOptions"},{"Lang":"ja","Value":"サーバ オプション"},{"Lang":"cn","Value":"服务器选项"}]}],"Documentation":[],"Files":[{"Bytes":"28252540","DateModified":"2025-03-07T08:15:24","FileList":["/CP065661_BUILD_2.data","/CP065661.vmexe64","/CP065661.vmfile","/CP065661_VMw.zip","/CP065661.xml","/payload.json","/CP065661_VMw.zip/index.xml","/CP065661_VMw.zip/vendor-index.xml","/CP065661_VMw.zip/metadata.zip","/CP065661_VMw.zip/vib20/CP065661/HPE_bootbank_CP065661_8.55.12.2-1OEM.900.0.24580437.vib","/CP065661_VMw.zip/metadata.zip/vendor-index.xml","/CP065661_VMw.zip/metadata.zip/vmware.xml","/CP065661_VMw.zip/metadata.zip/vibs/CP065661-6889978624787216928.xml","/CP065661_VMw.zip/metadata.zip/bulletins/Smart-Component-CP065661_8.55.12.2-1OEM.900.0.24580437.xml"],"MD5Sum":"544d5b805af13b85667607a585cc59c0","Name":"CP065661.zip","Release":"2025-03-07T08:14:11","Revision":"B","SHA1Sum":"9fd69a2f7d5a2b9c1bb57c6ec029bb3631c7a5b6","SHA256Sum":"4d545401f05a022c7c1f4e49529962bda8eabe2bb67d9146ac93ad23d0df9418","Size":"26MB","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP065661","Version":"8.55.12.2-1OEM.900.0.24580437"}]}],"Installation":{"Command":"","CommandParams":"","InstallCaps":{"NeedUserAction":"no","Silent":"no"},"PerDeviceInstallTimeSeconds":360,"RebootDetails":[{"Lang":"en","Value":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"Lang":"ja","Value":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"Lang":"cn","Value":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}],"RebootRequired":"yes","RebootRequirement":"Required"},"InstallationDependency":{},"InstallationNotes":[{"Lang":"en","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"ja","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"},{"Lang":"cn","Value":"<p>Manual installation instructions:</p><ol><li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li><li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li><li>Unzip the CPxxxxxx.zip file.</li><li>Install the VMware component.<ul><li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li><li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li></ul></li><li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li><li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li><li>Clean up the Smart Component:<ul><li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li><li>b. To clean up the Smart Component:<ul><li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li><li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li></ul></li><li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li></ul></li><li>If reboot is required to complete the firmware installation, reboot your system.</li></ol>"}],"ManufacturerName":[{"Lang":"en","Value":"Hewlett Packard Enterprise"},{"Lang":"ja","Value":"Hewlett Packard Enterprise"},{"Lang":"cn","Value":"惠普企业"}],"Name":[{"Lang":"en","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware"},{"Lang":"ja","Value":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"},{"Lang":"cn","Value":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware"}],"Prerequisites":{"RequiredDiskSpace":{"SizeKB":"1024"},"SupportedDevices":[{"Dev":"8070","SubDev":"0074","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770074","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0073","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770073","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0070","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770070","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0069","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770069","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0068","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770068","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0071","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770071","Type":"pci","Ven":"1077"},{"Dev":"8070","SubDev":"0072","SubVen":"1077","TargetGUID":"a6b1a447-382a-5a4f-1077-807010770072","Type":"pci","Ven":"1077"}],"SupportedOperatingSystems":[{"Major":"7","Minor":"0","Name":"VMware ESXi 7.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"8","Minor":"0","Name":"VMware ESXi 8.0","Platform":"vmware_esx_server","Sr":"OEM"},{"Major":"9","Minor":"0","Name":"VMware ESXi 9.0","Platform":"vmware_esx_server","Sr":"OEM"}],"SupportedPlatforms":true},"ReleaseDate":"2025-03-13T08:40:55","RevisionHistory":[{"ReleaseNotes":[{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"en"},{"Enhancements":"<p>この製品は、NPAR有効化オプションをサポートするようになりました。</p>","Fixes":"<ul><li>この製品には、サポートPLDMファームウェアアップグレードベースの改善が含まれています。</li><li>この製品は、以下のようにネットワークアダプターの過熱の問題に対処します。</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2ポート BaseT QL41132HLRJアダプター<br />HPE Ethernet 10Gb 2ポート BaseT QL41132HQRJ OCP3アダプター</p>","Lang":"ja"},{"Enhancements":"<p>This product now supported NPAR enabling option.</p>","Fixes":"<ul><li>This product contains support PLDM firmware upgrade base improvements.</li><li>This product addresses an overheat issue on the network adapters as below,</li></ul><p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>","Lang":"cn"}],"Version":"8.55.12"}],"SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SchemaVersion":"2.0.0.0","SupportedProducts":[{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL380 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL365 Gen10 Plus Server"},{"Family":"U46","Model":"HPE ProLiant DL360 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL345 Gen10 Plus Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"Family":"A43","Model":"HPE ProLiant DL325 Gen10 Plus Server"},{"Family":"A47","Model":"HPE ProLiant XL675d Gen10 Plus Server"},{"Family":"A48","Model":"HPE ProLiant XL645d Gen10 Plus Servers"},{"Family":"U47","Model":"HPE ProLiant XL290n Gen10 Plus Server"},{"Family":"A46","Model":"HPE ProLiant XL225n Gen10 Plus Server"},{"Family":"U47","Model":"HPE ProLiant XL220n Gen10 Plus Server"},{"Family":"U48","Model":"HPE ProLiant MicroServer Gen10 Plus Server"},{"Family":"U47","Model":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"Family":"U50","Model":"HPE Apollo 4200 Gen10 Plus Server"},{"Family":"A42","Model":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"Family":"U56","Model":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"Family":"H10","Model":"HPE Edgeline e920t Server"},{"Family":"U61","Model":"HPE ProLiant ML30 Gen10 Plus Server"},{"Family":"U60","Model":"HPE ProLiant DL20 Gen10 Plus Server"},{"Family":"H10","Model":"HPE Edgeline e920d Server"},{"Family":"H10","Model":"HPE Edgeline e920 Server"},{"Family":"U46","Model":"HPE ProLiant with vSphere Distributed Services Engine"},{"Family":"U38","Model":"HPE ProLiant XL170r Gen10 Server"},{"Family":"","Model":"HPE Apollo 2000 Gen10 Plus System"}],"UpgradeRequirements":"Recommended"},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"VersionId":"651fca6cd1d24e9787d1480774b0ba84"}]}],"SchemaVersion":"1.0"}